Contents
OPERATING INSTRUCTIONS
1. Environments Requirement
2. Main Tester Description
3. Wireless Module Description
4. Main Machine Connection
5. Wireless Module Connection
5.1 2/6/12 wireless modules (for 2V) connection
5.2 2/6/12 wireless modules (for 12V, 6V) connection
5.3 1.2/2 wireless modules (for 1.2V, 2V) connection
6. Starting Up And Input Operation
7. Some Important Setting Before Testing
8. Checking The Connection Of The Wireless Modules
9. Start Testing
9.1 Test Mode Selecting
9.2 Single Discharge Test
9.3 Single Charge Monitoring
9.4 Charge/Discharge Cycle Test
10. Monitor Function
11. Downloading Data To PC
12. Setup Interface
13. Calibration Interface
PC SOFTWARE INSTRUCTIONS
14. Software’s Main Functions
15. Installing Analysis Software To PC
16. Real Time Recording During The Testing
17. Download Data File From USB Disk
18. Generate Excel Test Report
ATTENTION
a) For testing safety and efficiency, please read the manual before operation.
b) If the user requires the capacity estimation for each cell in the battery groups,
wireless modules are essential accessories. Without them, the PC analysis software
can’t provide the voltage records and estimate the capacity.
c) If overheating or over-current equipment failure occurs during a test, the
warning alarm will activate automatically. Please turn off the AC power source to
avoid further damage.
SBS-200CT USER MANUAL
OPERATING INSTRUCTIONS
1. Environment
Should be NO CORROSIVE, NO EXPLOSIVE, NO ELECTRICAL BREAKDOWN AIR OR
CONDUCTIVE DUST.
2. Main Tester Description
LCD touch screen
Cooling fans
Wheels
SBS-200CT Front Side
Sockets panel
Power cable sockets
SBS-200CT Back Side
Additional control
socket
USB port
Wired module socket
Antenna
RS232 port
Power switch
Current
measurement socket
AC input socket
1 / 23
SBS-200CT USER MANUAL
3. Wireless Module Description
SBS-200CT Socket Panel
Power light (green)
Communication light
(red)
Alligator clip
(4 yellow, 1 red, 1 black)
Wireless module for 2V/6V/12V
Power light (green)
Communicate light
(red)
Alligator clip
(4 red, 1 black)
Wireless module for 1.2V/2V
4. Main Machine Connection
4.1 AC power source connection
SBS-200CT Socket Panel
110V 60Hz Power
Source
(Optional: 220V 50Hz)
Power supply cord
2 / 23
SBS-200CT USER MANUAL
4.2 Power Cable Connection
Connect SBS-200CT with the battery group being tested and battery charger.
(Only connect to the battery group being tested if charger isn’t being utilized)
Battery Charger
Battery Group
3 / 23
SBS-200CT USER MANUAL
5. Wireless Module Connection
Before connecting, please install the antenna on the main tester.
5.1 2/6/12 wireless modules (for 2V) connection
Wiring Hint
2/6/12 Wireless module
Black
Wireless module and corresponding battery number
For example: NO.1 module -- Connect the NO.1-NO.4 (from positive electrode)
NO.2 module -- Connect the NO.5-NO.8 (from positive electrode)
NO.3 module -- Connect the NO.9-NO.12 (from positive electrode)
………..
Cell
Cell
Cell
Cell
NO.1
NO.2
NO.3
NO.4
Cell
Cell
Cell
Cell
NO.5
NO.6
NO.7
NO.8
Cell
Cell
Cell
Cell
NO.4K+1
NO.4K+2
NO.4K+3
NO.4K+4
NO. 1 Wireless module
NO. 2 Wireless module
NO. K Wireless module
5.1.1 Please note the module number on the labeled modules and connect to the
corresponding batteries. Do not connect the modules to 4 batteries/cells that are
not in sequence, (EX: NO.1,3,8,9) - this will damage the modules.
5.1.2 Use the alligator clips (1 red, 1 black, 4 yellow) to connect the modules to the
Batteries; please follow the right wiring rule “Yellow 1 to Yellow 4, from long to
short”. A wiring diagram is available on the module’s label.
4 / 23
SBS-200CT USER MANUAL
5.2 2/6/12 Wireless Modules (for 12V, 6V) Connection
Wiring Hint
2/6/12 Wireless module
Black
Wireless module and corresponding battery number
For example: NO.1 module -- Connect the NO.1-NO.4 (from positive electrode)
NO.2 module -- Connect the NO.5-NO.8 (from positive electrode)
NO.3 module -- Connect the NO.9-NO.12 (from positive electrode)
………..
Cell
Cell
Cell
Cell
NO.1
NO.2
NO.3
NO.4
Cell
Cell
Cell
Cell
NO.5
NO.6
NO.7
NO.8
Cell
Cell
Cell
Cell
NO.4K+1
NO.4K+2
NO.4K+3
NO.4K+4
NO. 1 Wireless module
NO. 2 Wireless module
NO. K Wireless module
5.2.1 Please note the module number on the labeled modules and connect to the
corresponding batteries. Do not connect the modules to 4 batteries/cells that are not
in sequence, (EX: NO.1,3,8,9) - this will damage the modules.
5.2.2 Use the alligator clips (1 red, 1 black, 4 yellow) to connect the modules to the
batteries, please follow the right wiring rule “Yellow 1 to Yellow 4, from long to
short”. A wiring diagram is available on the module’s label.
5 / 23
SBS-200CT USER MANUAL
5.3 1.2/2 Wireless Modules (for 1.2V, 2V) Connection
Wiring Hint
1.2/2 Wireless module
Black
Wireless module and corresponding battery number
For example: NO.1 module -- Connect the NO.1-NO.4 (from positive electrode)
NO.2 module -- Connect the NO.5-NO.8 (from positive electrode)
Red 4
NO.3 module -- Connect the NO.9-NO.12 (from positive electrode)
………..
Cell
Cell
Cell
Cell
NO.1
NO.2
NO.3
NO.4
Cell
Cell
Cell
Cell
NO.5
NO.6
NO.7
NO.8
Cell
Cell
Cell
Cell
NO.4K+1
NO.4K+2
NO.4K+3
NO.4K+4
NO. 1 Wireless module
NO. 2 Wireless module
NO. K Wireless module
5.3.1 Please note the module number on the labeled modules and connect to the
corresponding batteries. Do not connect the modules to 4 batteries/cells that are not
in sequence, (EX: NO.1,3,8,9) - this will damage the modules.
5.3.2 Use the alligator clips (1 red, 1 black, 4 yellow) to connect the modules to the
batteries, please follow the right wiring rule “Yellow 1 to Yellow 4, from long to
short”. A wiring diagram is available on the module’s label.
6 / 23
SBS-200CT USER MANUAL
6. Starting Up And Input Operation
6.1 After the main tester is connected, turn
on the power switch.
6.2 On the welcome screen, you can see
our company name & logo and the
tester name. Press any key to access the
main menu, after 10 seconds,
the system will automatically open the
main menu.
6.3 SBS-200CT input: press on the
touch screen directly
SBS-200CT socket panel
Power switch
Main Menu
7. Important Settings Before Testing
Please remember to check the settings before each test.
Other settings will be introduced in “12. Setup interface”
7.1 Press “Setup” on the main menu screen to enter Setup menu
Date & Time setting
Setup
ConfigModuleAddr: activate
spare modules, disconnect all
other modules, connect the
BatteryLowAct: the
backup module with 4
operation when any
adjacent batteries, input the
battery reaches the
module number you need, for
“BattLow”, Stop or
example #5, and press
Pause
“Config”, the backup module
will be #5 module.
BattOrder: This will
determine how the
wireless modules will be
connected, you can
select the positive or
negative electrode
Back to the main menu
“SaveTimeInterval”: the data recording interval.
ModuleFrq: the
communication
frequency of the wireless
modules. Default setting
is “01FM”
“EstimatedRecordTime”: Total recording time
available for internal memory. This is based on
“SaveTimeInterval”.
When “SaveTimeInterval” is set for a longer period,
“EstimatedRecordTime” will increase automatically.
7 / 23
Press “Modify” to locate the preset
parameters need to be changed, “+”,
“-” to change value, “Cancel” to quit.
After all setting, press “Apply” to save
SBS-200CT USER MANUAL
7.2 Set the date and time; this will be the Data File name of the recorded test data.
7.3 Set “BattOrder”, the sequence of wireless modules connecting from the
positive or negative electrode.
7.4 Set “SaveTimeInterval”, the data recording interval. The shorter the recording
interval the more memory the test will utilize; the longer the recording interval, the
less internal memory will be used.
If the internal memory is totally empty, It can record:
150 hours for 1 min interval,
300 hours for 2 min interval,
600 hours for 3 min interval,
….
To check the unit’s remaining memory, press “Data” in the Main Menu
The percentage of memory remaining
Main Menu
Data
8. View Individual Cell Voltages
8.1 Press “Monitor” in the main menu, then Press “Batt” to access individual cell
monitoring. If all wireless modules are connected correctly, you can see the voltage of
each battery. If the voltages of some batteries are not visible, please check the
wireless modules connection.
Main Menu
Monitor
8 / 23
SBS-200CT USER MANUAL
The highest & lowest voltage
Table
Only 24 batteries can be viewed on
the screen. Press “Next” or “Prev” to
see more data
in battery group
Chart
Back to the main menu
8.2 Press “Chart” to see the histogram of each battery
8.3 In both table and chart screens, only 24 batteries can be viewed at one time; if
the tested battery group has more than 24 batteries, press “Next” & “Prev” scroll to
the rest
8.4 Press “Exit” go back to the main menu
9. Start Testing
9.1 Test Mode Selecting
Press “Test Mode” in main menu to select the test mode.
“SingleDCH”------------Single discharge test
“SingleCHG”------------Single charge monitoring
“CycleTest”-------------Charge/discharge cycle test
Test Mode
Main Menu
9 / 23
SBS-200CT USER MANUAL
9.2 Single Time Discharge Test
9.2.1 Press “SingleDCH” to enter single discharge test mode
9.2.2 In “DCHParam” enter the parameter settings.
Capacity: The rated capacity
of the tested battery group
HourRate: The hour rate of
discharge
Test Mode
Discharge Parameter
BattSum: the battery quantity
CurrSet: The current of
in the battery group
discharge (automatic change
according to “Capacity” &
GroupSum: The number of
battery groups being
discharged
“HourRate”)
CapaSet: the capacity need to
GroupLow: the lower limit
be discharged
voltage of battery group
TimeSet: the discharge time
BattLow: the lower limit
Back to the main menu
voltage of the single battery
BattLows: the quantity of the
To load the preset you need
Press “Modify” to locate the preset parameters need
to be changed, “+”, “-” to change value, “Cancel” to
batteries which voltages
quit. After all setting, press “Apply” to save, the
below the “BattLow”
changes will be saved.
9.2.2.1 “CapaSet”, “TimeSet”, “BattLow”, “GroupLow” are all discharging stop
Conditions; if any of them are reached, the discharge will be stopped automatically
9.2.2.2 For 1 battery group being discharged, please keep “GroupSum” in “001G”, if 24 groups will be parallel discharged simultaneously, they need 2-4 times the wireless
modules and the current will be 1/2-1/4 for each group.
9.2.2.3 If you want discharging to stop when one battery reaches the “BattLow”
parameter, keep “Battlows” at “001#”. If you want the discharging to stop when X no.
of batteries reaches the “BattLow”, set the “BattLows” parameter to that number
(“00X#”).
9.2.2.4 If you don’t need wireless modules in the discharge, please set the “BattSum”
to “000#”. “BattLow” will be disabled as a parameter.
10 / 23
SBS-200CT USER MANUAL
9.2.3 Press “Start” to enter discharge mode, then press “Start” again to start the
discharge. You will hear the sound of the internal breaker.
Discharge
Discharge Parameter
When the discharging starts, you can see the status in this
To browse all batteries
Change the parameters in the
Screen; it includes:
voltage, “Table” & “Chart”
process of discharging; all changes
ChargerVol: the voltage of battery charger
screens
can be activated immediately!
GroupVol: the voltage of battery group
CurrentSum: the discharge current
CapacitSum: the capacity already be discharged
ConsumTime: the time since the discharge starts
BattLowSum: the quantity of the batteries which voltage
already below the “BattLow” you set
MaxBatt(V): the highest voltage battery in the group
MinBatt(V): the lowest voltage battery in the group
9.2.4 To manually stop the discharge: press “Pause” to pause the discharge, and
press “Stop” to end the discharge or “Start” to continue the discharge.
9.2.5 Press “Param” to change the parameters during the discharging (if necessary),
all changes can be activated immediately and the discharging will not be stopped.
9.2.6 “SysState:” in the discharge interface it will help you know the status of the
discharge.
11 / 23
SBS-200CT USER MANUAL
9.3 Single Charge Monitoring
9.3.1 Press “SingleCHG” to enter single charge monitoring mode.
Test Mode
Charge Parameter
9.3.2 in “CHGParam” (Charge parameter interface), finish all parameters setting.
Capacity: The rated capacity
of the tested battery group
Charge Parameter
Press “Modify” to locate the
preset parameters need to be
BattSum: the battery quantity
changed, “+”, “-” to change value,
in the battery group
“Cancel” to quit. After all setting,
press “Apply” to save, the
changes will be saved.
GroupSum: The number of
battery groups being charged
ChrgCapa: The capacity needed
to charged the battery
ChrgCurr: the end charge
current
ChrgTime: The charge time
9.3.2.1 “ChrgCapa”, “ChrgTime”, “ChrgCurr” are all the charging stop conditions; if
any of them are reached, SBS-200CT will cut the channel between battery group and
battery charger automatically.
9.3.3 Press “Charge” into Charge interface, and Press “Start” again to start charge
Monitoring. (You will hear the sound of internal breaker.) SBS-200CT will monitor
the current and voltage from the battery charger.
12 / 23
SBS-200CT USER MANUAL
Charge
When the charging starts, you can see the status in this
Screen; it includes:
ChargerVol: the voltage of battery charger
GroupVol: the voltage of battery group
CurrentSum: the charge current
CapacitSum: the capacity that has been charged
ConsumTime: the time since the charge starts
MaxBatt(V): the highest voltage battery in the group
MinBatt(V): the lowest voltage battery in the group
To browse all batteries
Change the parameters in the
voltage, “Table” & “Chart”
process of charging; all changes can
screens
be activated immediately!
9.3.4 To manually stop the charge: press “Pause” to pause the charge, and press
“Stop” to end the charge, or press “Start” to continue the charge.
9.3.5 Press “Param” to change the parameters during the charge (if necessary), all
changes can be activated immediately and the charging will not be stopped.
9.3.6 “SysState:” in the charge interface it will help you know the status of the
charging.
9.4 Charge/Discharge Cycle Test
9.4.1 Press “CycleTest” into charge/discharge cycle mode,
Test Mode
Cycle Parameter
9.4.2 in “CycleTest” (cycle parameter interface); finish all parameter settings.
13 / 23
SBS-200CT USER MANUAL
Capacity: The rated capacity
GroupLow: the lower limit voltage
of the tested battery group
HourRate: The hour rate of
of battery group
Cycle Parameter
DchgWait: the stop time from
discharge
charge to discharge
CurrSet: The current of
ChrgCapa: the capacity needed to
discharge (automatic change
charge the battery
according to “Capacity” &
“HourRate”)
ChrgTime: the charge time
CapaSet: Total discharge
capacity
ChrgCurr: the end charge current
TimeSet: the discharge time
ChrgWait: the stop time from
discharge to charge
BattLow: the lower limit
voltage of the single battery
BattLows: the quantity of the
batteries which voltages
below the “BattLow”
TestFrom: the cycle start from discharge(DCH) or charge (CHG).
TestTimes: the cycle times
Example:
If TestFrom is “CHG”,
BattSum: the battery quantity
in the battery group
TestTimes is 001, Only single charge
TestTimes is 002, charge-->discharge
TestTimes is 003, charge-->discharge-->charge
GroupSum: the group
number for once testing
TestTimes is 004, charge-->discharge-->charge-->discharge
….
If TestFrom is “DCH”,
TestTimes is 001, Only single discharge
TestTimes is 002, discharge-->charge
TestTimes is 003, discharge-->charge-->discharge
TestTimes is 004, discharge-->charge-->discharge-->charge
….
9.4.2.1 “CapaSet”, “TimeSet”, “BattLow”, “GroupLow” are all the discharging stop
conditions, if any of them are reached, the discharge will be stopped automatically
9.4.2.2 “ChrgCapa”, “ChrgTime”, “ChrgCurr” are all the charging stop conditions, any
of them is reached, SBS-200CT will cut the channel between battery group and
battery charger automatically
9.4.2.3 For discharging 1 battery group, please keep “GroupSum” in “001G”; if
2-4 groups are parallel discharged at one time, you will need 2-4 times the wireless
modules, and the current will be ½ - ¼ for each group.
14 / 23
SBS-200CT USER MANUAL
9.4.2.4 To stop discharging when one battery reaches the “BattLow” parameter, keep
“Battlows” at “001#”. If you want the discharging to stop when X no. of batteries
reaches the “BattLow”, set the “BattLows” parameter to that number (“00X#”).
9.4.2.5 If the wireless modules are not needed during the discharge, please set the
“BattSum” to “000#”. “BattLow” will be disabled as a parameter.
9.4.3 Press “Start” in the cycle menu,
If you set “TestFrom” to “DCH”, the cycle will start from Discharge.
If you set “TestFrom” to “CHG”, the cycle will start from Charge.
Press “Start” again to start discharge or charge (you will hear the sound of the
internal breaker). SBS-200CT will start all discharge/charge cycles. When a
stop condition is reached, it will go to the next step automatically.
Discharge or Charge
Cycle Parameter
In discharge interface:
To browse all batteries’
Change the parameters in the
ChargerVol: the voltage of battery charger
voltage, “Table” & “Chart”
process of discharging or charging;
GroupVol: the voltage of battery group
screens
all changes can be activated
CurrentSum: the discharge current
CapacitSum: the capacity already be discharged
ConsumTime: the time since the discharge starts
BattLowSum: the quantity of the batteries which
voltage already below the “BattLow” you set
MaxBatt(V): the highest voltage battery in the group
MinBatt(V): the lowest voltage battery in the group
In charge interface:
ChargerVol: the voltage of battery charger
GroupVol: the voltage of battery group
CurrentSum: the charge current
CapacitSum: the capacity already be charged
ConsumTime: the time since the charge starts
MaxBatt(V): the highest voltage battery in the group
9.4.4 Manually stop the cycle: press “Pause” to
pause the cycle, and press “Stop” to end the
cycle, or press “Start” to continue the cycle.
9.4.5 Press “Param” to change the parameters
during the cycle (if necessary), all changes can
be activated immediately and the cycle will not
be stopped.
9.4.6 “SysState” in the discharge or charge
interface it will help you know the status of the
discharge or charge.
9.4.7 “TestPro” will show you the recent step
and the step number of the whole cycle.
MinBatt(V): the lowest voltage battery in the group
15 / 23
SBS-200CT USER MANUAL
10. Monitor Function
The SBS-200CT provides an interface for monitoring the batteries freely. It can
monitor and record all cell voltages during discharge, charge or floating charge. For
this function, the SBS-200CT only needs to connect with an AC power source with the
wireless modules connected to each cell.
10.1 Press “Monitor” in the main menu into “Monitor” menu.
10.2 Press “Start” to start monitoring.
Main Menu
Monitor
To browse all batteries
When the monitoring starts, you can see the status in this screen, it
voltage, “Table” & “Chart”
includes:
screens
ChargerVol: the voltage of battery charger
GroupVol: the voltage of battery group
CurrentSum*: the discharge or charge current
CapacitSum*: the capacity already be charged or discharged
ConsumTime: the time since the charge starts
MaxBatt(V): the highest voltage battery in the group
MinBatt(V): the lowest voltage battery in the group
Note: external current clamp needed for parameters with *.
10.3 To manually stop monitoring: press “Pause” to pause the monitoring, and press
“Stop” to end the monitoring, or press “Start” to continue the monitoring.
10.4 “SysState” in the monitoring interface it will help you know the status of the
monitoring.
11. Download The Data To PC
SBS-200CT provides two ways to record the test data:
a) Use the RS232 cable to connect to the main unit with a PC or laptop. The analysis
software will display data in real time on the PC which can be downloaded during the
test.
16 / 23
SBS-200CT USER MANUAL
b) The internal memory saves all of the testing data. You can download the data via
USB disk or RS232 cable to a PC or laptop.
11.1 Press “Data” in the main menu to access the “Data” menu
Data
The used percentage of internal
Memory; if this value is low please
delete some old data
The information on the data file
Test time
Delete the chosen file
& date
Delete all data files
Back to the main menu
Use RS232 wire to connect main
If the data files are more than 1
Plug USB disk into the USB port,
machine with PC; download the
page, use “Up” “Down” to browse
press “USB” to download the
chosen file by analysis software
chosen file
12. Setup Interface
12.1 Press “Setup” in main menu to enter “Setup” menu
Date & Time setting
Setup
ConfigModuleAddr: activate
spare modules, disconnect all
other modules, connect the
BattLowAct: the
backup module with 4
operation when any
adjacent batteries, input the
battery reaches the
module number you need, for
“BattLow”, set Stop or
example #5, and press
Pause
“Config”, the backup module
will be #5 module.
BattOrder: order the
wireless modules
connect to the battery
string: set lowest # to
start at positive or
negative electrode
Back to the main menu
“SaveTimeInterval”: the data recording interval.
ModuleFrq: the
“EstimatedRecordTime”: max recording time of
frequency of wireless
internal memory, is based on “SaveTimeInterval”.
module; the default
If set “SaveTimeInterval” higher value,
setting is “01FM”
“EstimatedRecordTime” will go up automatically.
17 / 23
Press “Modify” to locate the preset
parameters needing to be changed, “+”,
“-” to change value, “Cancel” to quit.
After all settings, press “Apply” to save
SBS-200CT USER MANUAL
In “7. Some Important Settings Before Testing” we already introduced some
parameters in the “Setup” menu. Please read below for more settings.
12.2 BatteryLowAct: the operation when any battery reaches the “BattLow”, set
Stop or Pause. (Usually, “Stop” is recommended.)
12.3 ModuleFrq: the frequency of wireless module. All wireless modules provided
are set at the default frequency of “01FM”.
If you need 2-3 units of the SBS-200CT working in the same area at the same time,
the wireless modules may need to be set to different frequencices to avoid
interference.
For example:
Set the first set of modules to “01FM”, and work with wireless modules in “FM1”
(Currently shown on label of the modules)
The second set, set to “02FM”, and work with wireless modules in “FM2”
The third set, set to “03FM”, and work with wireless modules in “FM3”
12.4 ConfigModuleAddr: To activate spare modules, disconnect all other modules,
connect the backup module with 4 adjacent batteries, input the module number you
need, (for example #5), then press “Config”; the backup module will now be the #5
module.
13. Calibration Interface
The SBS-200CT provides a calibration function; if you have high accuracy
instruments, you can calibrate the tester. Change the date to 2099-12 (year-month),
and the “Cal” button will be activated. Press “Cal” to enter the “Calibrate” menu.
GroupVol: calibrate the
Calibrate
Press “Cal” to select the
parameters needing to be
voltage of battery groups
calibrated, “+”, “-” to change
Dischg: calibrate discharge current
value, “Cancel” to quit, and
“Apply” to save the changes.
Charge: calibrate charge current
Clamp: calibrate external current clamp
TEMPE: calibrate the temperature
Back to setup interface
BattVol: calibrate the battery voltage
Dischg: to start discharge for calibrating
discharge current
18 / 23
SBS-200CT USER MANUAL
PC Software Instruction
14. Software Main Functions
a) Recording the real time discharge data by connecting main machine to a PC
b) Read, display and save the downloaded USB data.
c) Generate EXCEL report
15. Install Analysis Software To PC
15.1 Please find the install program of analysis software on the CD-ROM.
15.2 Following the prompts, finish the installation.
15.3 After the installation, you can click the desktop icon to open the software.
PC Explorer
Install Program
Desktop Icon
Main Interface
19 / 23
SBS-200CT USER MANUAL
16. Real Time Recording During The Testing
16.1 Use the RS232 connector to connect the main machine with a PC
RS232 to USB
Converter
RS232 wire
PC
16.2 Choose “Connect” in “Realtime monitoring” menu to open “Real-time
Monitoring Links” menu.
Instrument types:
Battery Information: input some information
choose “IDCE-CT” For
on the test battery group (the red parameters
SBS-200CT
are mandatory)
Communication Port:
Choose the COM port number (you
can find it in the Device Manager)
Battery Group Qty(G): the tested
battery group number once time
(usually choose “1”)
Save Data: after all input, press
“Save” to create a “*.FGDF” file to
save the real time data. If you test
more than 1 group at a time,
“Duplicate” can create files for
each “group” data recorded.
After saving the file, press “Connect” to access the real time data
16.3 Start the discharge and the real time data will update automatically on the PC.
20 / 23
SBS-200CT USER MANUAL
16.4 The real time data can be saved simultaneously. If the software is closed during the
discharge, the data file will display the readings up to the point of the software being closed.
17. Download Data File From USB Disk
17.1 To download the data file from the SBS-200CT, you can find the data file named
“Fxxxxxxxx.FBO”. (“xxxxxx” is the time & date of data downloading.)
17.2 Double click the file to access “Battery Information” menu or you can open
the software first and choose “Open File” in “File” menu.
PC Explorer
The software can load the parameters which you set in main machine
automatically and you can fill in the other non essential information or
change the mandatory parameters here.
Main Interface
21 / 23
SBS-200CT USER MANUAL
17.3 In the main menu, you can see six windows that show all the necessary testing
information:
a) Total current chart: the current during the discharging (the values are
negative because of discharging)
b) Cell curve: the voltage curve of each battery. They can be added and deleted by
right clicking on the chart
Input the battery number range
you want to be displayed or hid
c) Cell capacity-rest capacity: shows the rest capacity, actual capacity and capacity
percent of each battery (it can be displayed by right clicking on the chart)
d) Data form: shows the discharge data by time-interval during the discharge
e) Cell voltage: each battery voltage can be displayed by bar chart, the bar chart
can show you the initial and end voltages. Using the scroll bar on the top of this
window, you can scroll at any time during the test to see the relevant results.
f) Total voltage: the voltage curve of battery group during the discharging process
18. Generate Excel Test Report
18.1 Press
icon to generate a report. In the “System Information” window, it will
indicate the number of pages generated for the report. Choose “No” to generate an
Excel report which includes all of the information generated. To reduce the number
of pages generated, press “Yes” to generate an Excel report which has the page
number you prefer.
Excel PageChoice
Generate an Excel report with
the number of pages preferred
22 / 23
Generate an Excel report which
includes all generated data.
SBS-200CT USER MANUAL
18.2 In the “compress report” screen, input the page number you want, and choose
“compress report” to decease the page number. Then choose “Export Report” to save
the Excel report.
Generate an Excel report with the
number of pages you prefer
Recover the pages of the data
file
Back to main menu
23 / 23