VENTILATION FAN CATALOGUE Proven, Reliable Bathroom Ventilation Solutions Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans. MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens. PROVEN: Trusted Locally, Proven Globally. RELIABLE: Durable Ball Bearing Motors with a 5 Year Warranty. SOLUTIONS: A Complete Range of Fans, Ducting and Accessories. Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141 Western Australia South Australia Unit 2, 22 Hammond Rd Cockburn Central WA 6164 86A Richmond Rd Keswick SA 5035 Victoria Queensland 2/13-15 Brough St Springvale VIC 3171 26 Turbo Drive Cooparoo QLD 4151 Tasmania Newcastle Electrical Agencies 4 Linear Court Moonah TAS 7009 Nick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322 National Support Centre Phone: 1300 666 595 Fax: 1300 666 594 Email: austsales@tnb.com Web: www.manrose.com.au Manrose continues to lead the way as the “ventilation solution providers” Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans. Thomas and Betts have been supplying the electrical wholesale market for over 35 years and credit their success to outstanding delivery and customer service capabilities and are proud of their strong, long-standing partnerships. They represent the highest quality and most innovative products available. The MANROSE brand is known for proven, reliable solutions with an evolving product range to meet the demands of the market. Thomas & Betts and MANROSE have a strong relationship, which has seen ventilation products developed specifically for the Australian market with features demanded by the customer. This has led to all Manrose products being upgraded with ball bearing motors and a 5 year warranty. Within the Manrose range you can choose from a Classic model which offers trusted performance or a Pro-Series model with higher specifications, installation advantages and features to the contractor, as well as sought after aesthetics demanded by the consumer. A recent addition to the range is Vent-Axia Lo-Carbon range that offer ventilation fans with up to 70% energy savings. The Manrose product development team is consistently developing high quality products with features demanded by the market. Our policy of ongoing investment in product development has been a key force in driving the company to the forefront of the ventilation market. Manrose has an extraction fan for every application. Continual development and innovation ensures that future market demands are not only met but exceeded! Lo-Carbon PUB0385 Iss03 04/13 contents Ventilation Selection/Regulations 3-9 Selection Chart 10 Ventilation Fans 12-63 Wall/Ceiling Fans 12-21 Thru Wall Fan Kits 22-25 Window Mounted Fans 26-29 Heat/Fan/Light Kits 30-31 In-Line Fan Kits 32-53 Wall Mounted Fans 54-55 Thru-Roof Mounted Fans 56-57 Hand Dryers 58-59 Specialised Fans 60-61 Fan Accessories 62-63 Duct and Fittings 64-79 Duct Standards Ducting Installation & Usage 64 65-71 Aluduct/Comflex Flexible Ducting 72 Unilok73 Ceiling Diffuser 84-86 Designer Ceiling Diffuser 84 Flat Ceiling Diffuser 84 Ceiling Diffuser 85 Eggcrate Round Diffuser 85 Ceiling Diffuser 86 Cowls/Plate Grilles 87-94 Designer Weatherproof Cowls 87 Weatherproof Cowls 87 Designer Weatherproof Dome 88 Wall/Ceiling Plate Grilles 89 Wall/Ceiling Plate Grilles 89 Door Grille 89 Duct Kits 90-93 Roof Cowls 90-91 Rangehood Ducting Kits 92 Dryer Ducting Kit 93 Pro Series Extension Kit 93 PVC74 Accessories94 Semiduct Semi Rigid Heat Trans Low Profile Ducting 74 75-78 In-Line 78 Branch Take Off 79 Alpha-Numeric Index Vent-Axia Lo Carbon Range 95-97 98-100 101-104 Reducers79 Duct Joiners/Spigots 79 Wall/Ceiling Grilles 80-83 Designer Wall Grilles 81 Wall Grilles 81 Wall/Ceiling Grilles 82 Designer Wall/Ceiling Grilles 83 Wall/Ceiling Grilles 83 Technical Information Product category index Technical information such as dimensions and size charts can be found beneath or on the page following the product page. The product category index is an alphanumeric listing of general product groups in the Thomas & Betts portfolio, this can be found on page 98. 2 VENTILATION SELECTION Why you need Ventilation? • New building materials and construction methods are effectively resulting in “waterproof” buildings. They trap moisture inside just as effectively as they keep moisture out. • Open doors and windows provide air circulation and ventilation but security considerations mean that we are increasingly less likely to use this option. As a result houses tend to remain closed up more often. • Poor ventilation results in a buildup of moisture generated by cooking/bathing/showering/clothes washing- drying/LPG gas heating...even breathing! • Stale air can be caused by cooking smells, odours remaining in the bathroom, a general lack of ventilation around the house as well as a damp atmosphere. Problems Caused by Poor Ventilation • All these problems cause an avoidable level of discomfort as well as the risk of respiratory illness and general poor health. • Problems also occur when steam from the kitchen or bathroom finds cooler surfaces around the house on which to condense. Warm, moisture-laden air condenses on cold surfaces such as glass, cold ceilings and cold wet-wall linings. This is the moisture that you can see. • Moisture you cannot see is still present in the atmosphere and will be absorbed into fabrics, wall linings, bedding, etc. Attempts to conserve heat by sealing windows and therefore reducing natural ventilation makes this problem even worse. • Condensation can cause considerable problems from peeling wallpaper and mould growth to severe long term structural damage to building materials. Moisture Generators: BATHROOM CONDENSATION SHOWERING GAS HEATING KITCHEN TOILET LAUNDRY BREATHING WATERING PLANTS Stale air out Correct Ventilation Ventilate Outside = Healthy Home Incorrect Ventilation Trapped moist air Inside the home = Unhealthy In dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly into the roof space is not permitted under the Building Code. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 3 VENTILATION SELECTION Your Ventilation Solutions Damp air out It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Fresh air in It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Use ducted fans, through-wall fans or window fans at all times. DO NOT use ceiling fans which discharge into the ceiling cavity, this only moves the problem. Moisture will permeate insulation and ceiling linings causing further problems. In particular with bathrooms think in terms of “room-conditioning”. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel. Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation. Fan Placement Careful location of an extraction fan will ensure maximum air-flow through the room. Air extracted from a bathroom, for example, can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door. This ensures that fresh air is being drawn into the entire house at regular periods. Switching the fan on before starting showering or cooking sets up effective air-flows before condensation problems occur. Closing doors to adjacent living areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door to replace extracted air. Use a door vent if necessary. For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room. E.g. air in = air out. An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at the bottom), you may need to fit a through-door grille to allow replacement air into the room. Poor Circulation 4 Medium Circulation Best Circulation VENTILATION SELECTION Fan Regulations What the law states Australian Building Code Paragraph 3.8.5.0 states: Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS 1668.2. “Mechanical ventilation for acceptable indoor air quality”, except that any contaminated air from a sanitary compartment or bathroom must: a. Exhaust directly to outside the building by way of ducts; or b. Exhaust into the roof space provided: i. It is adequately ventilated by open eaves, and/or roof vents; or ii. The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles. As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents. The Manrose range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the latest building code. Natural Ventilation for the above is acceptable as long as opening windows in each room have an area of 5% or more of the floor area of the room. AS1668 (summarised): “...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces; poisonous or flammable fumes and gases...” BCA Compliance to AS/NZ 1530 Part 3 Requirements are: Internal Surface: Spread of flame not >0 External Surface: Spread of flame not >7 Smoke Developed not >3 Smoke developed not >5 AS/NZS 1530 Part 3 This is the Australian standard 1530, method for fire tests on building materials components and structures. “Simultaneous determination of ignitability, flame propagation, heat release and smoke release” Bathrooms Kitchens The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed. The regulations require a fan capable of a minimum extraction capacity of 50 litres per second when installed. Toilets Laundries The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed. The regulations require a fan capable of a minimum extraction capacity of 20 litres per second when installed. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 5 VENTILATION SELECTION Calculating Fan Performance Litres/Second (l/s) Milk 1 Litre Working out the right fan for the job • Calculate the room volume in metres (l x W x H). Cubic Metres/Hour (m³/hr) 1m • Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit. 1m • The result is the total performance required in cubic metres per hour. 1m To convert from one to other types of measurement: If you know Litres/Second (l/s): l/s x 3.6 = m3/hr (e.g. 25 l/s x 3.6 = 90m³/hr). If you know Cubic Metres/Hour (m³/hr): m3/hr ÷ 3.6 = l/s (e.g. 200m³/hr ÷ 3.6 = 55.55 l/s). Note: 1m3 = 1000 Litres ACH AIR CHANGES PER HOUR (ACH) The number of times the total room volume of air is changed each hour. Refer to the table below for the recommended Air Changes per hour based on the room type. Select a fan with a higher performance than this figure. For Example: What is the best fan for a bathroom that is 2.8m long by 2.8m wide with a ceiling height of 2.4m? • Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4 = 18.8m3. • 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m3/hr. • The fan to choose for this bathroom would be a fan that performs at greater than 282m3/hr. • A fan that has a performance level of 313m3/hr or higher (e.g. XP150, or SF150) would do this job. Application Description Air Changes Per Hour Bathrooms 11 - 15 Kitchens - (domestic) 15 - 20 Laundries - (no drier) 6 - 10 Laundries - (with drier) 10 - 30 m³/hr l/s m³/hr ÷ 3.6 = l/s Toilets 6 - 10 cfm m³/hr cfm x 1.69 =m³/hr Bedroom 2-5 cfm l/s cfm x 0.47 = l/s Offices 6 - 10 Cafés 10 - 12 Quick Cross-Reference Calculations: Known To Find Action l/s m³/hr l/s x 3.6 =m³/hr Canteens 8 - 12 350 Garages 6-8 300 Kitchens - (commercial) 20 - 30 250 Restaurants 8 - 12 200 Factories 8 - 10 150 Stores & Warehouses 3-6 Libraries Classroom 6 3-5 5-7 240 110 400 220 100 200 90 180 80 160 70 140 60 120 50 80 30 100 50 0 100 40 m3/hr 60 20 40 10 20 l/s cfm m³/hr to l/s to cfm Comparison Chart VENTILATION SELECTION What Affects Performance? Simple facts: Smaller duct = greater resistance to airflow. More bends = greater resistance to airflow. Longer duct runs = increasingly reduced airflow. 01 Wrinkled ducting causes turbulence and reduces airflow: WRINKLED DUCT AIRFLOW Compare Centrifugal Against Axial Fan Performance: SF100 (axial) vs an SF200 (centrifugal) fan. The starting point is the free air performance of 23 l/s for the axial and 31 l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases volume of air moved. From the below example you can see that at 20Pa of pressure the 100mm axial fan airflow has stopped whereas the 100mm centrifugal fan is still moving 29 l/s! SF100 & SF200 PERFORMANCE GRAPH* 02 Smoother, extended ducting allows smooth, increased airflow: SMOOTH DUCT AIRFLOW SF200 SF100 Manrose ALUDUCT flexible ducting retains its stretched-out shape (for smooth airflow) far better than most competitive products. *Graphs are a visual representation only. Many competitive ducts tend to shrink back on themselves, wrinkling the duct fabric. ID150 (axial) vs a MAN150 (centrifugal) fan. The starting point is the free air performance of 89 l/s for the axial and 115 l/s for the centrifugal. Fan type Centrifugal: Pressure developing fans which achieve good flow against the resistance created in a ducted system. Particularly useful in venting areas like internal bathrooms/laundries, multi-room extraction systems, heat-transfer systems, etc. Mixed Flow: Powerful in-duct mounted fans, designed for applications that require high air flows, with low relative noise. Can handle more pressure than an axial fan, although not as powerful as a centrifugal fan. Axial: Suitable for wall, window and roof applications where they can extract directly to the outside. Short duct runs are an option but the length of duct should be limited. e.g. 100mm dia : 2-3m length 125mm dia : 3-4m length 150mm dia : 4-5m length As duct is added to each of these fans, this increases the pressure (Pa) and decreases the volume of air moved. From the below example you can see that at 120 Pa of pressure the 150mm axial fan airflow has stopped whereas the 150mm centrifugal fan is still moving 102 l/s! 0 72 144 216 288 360 432 504 30 MAN150 25 300 250 20 200 15 150 ID150 10 100 50 5 0 20 40 60 80 100 120 140 *Graphs are a visual representation only. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 7 Wet Areas & Recommended Fan Types When considering where in the room to place an extractor fan, you must consider the wet areas. Zone 1: This is the zone directly within the shower or bath up to 2.25 metres above the floor and 150mm around the bath/ shower cubicle. A SELV fan or an in-line fan kit will be required in this zone. Zone 1: Requires a SELV Fan or an In-Line fan kit For example if a fan is mounted directly over the bath or shower it must be a low voltage fan (SELV). Zone 2: Any fan model can be used Zone 3: Any fan model can be used Zone 2: This zone is 0.6 metres horizontally outside of zone 1 and up to 2.25 metres above the floor. Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally outside of zone 2 and 2.25 metres above the floor. Locate your Ventilation Fan Wet area zone guide Outside Zones Outside Zones Zone 1: Requires a Low Voltage Fan. Zone 2: Any fan model can be used. Zone 3: Any fan models can be used. How To Order Select the model that exhausts the closest to your requirements. If the performance required falls between two fans, it is recommended you select the one handling the most air. 8 VENTILATION SELECTION Fan Application Examples Location of your ventilation fan will depend on the physical constraints of your room. The wet area zone guide (shown on the previous page) will help you decide the most suitable physical installation to meet your requirements. Within the above mounting options there are various other features available, such as: • TIMER (maintain fan run-on after the room is vacated). • PULLCORD (Switch at fan, instead of wall switch control). • AUTO-SHUTTER (electrically operated shutters inside the fan - closed when the fan is not running to stop draughts). • PIR SENSOR (provide automatic motion-sensor control of fans). 1. Ceiling Mounted Fan 4. In-Line Mounted Fan Kit Designed for low-pitch roofs or between floors, where there is no ceiling access. Also available with heat lamps & lighting. Most common bathroom installation, the fan is mounted in the ceiling space with the grille directly above the source of the steam. Generally this type of installation is quieter as the fan is not directly in the room. 01 04 Page Reference 12-21 2. Thru Wall Fan Kit Used where the bathroom is on an external wall, or there is no ceiling space for an in-line fan. Page Reference 32-53 5. Thru Roof Kit 02 Used where there is limited access to the roof space, or where there is no soffit available. Thru Roof Kits can be used with any extraction fan, or use a Thru Roof Fan Kit with the fan mounted within the cowl. Page Reference 22-25 05 3. Window Mounted Fan Used in situations where an existing window fan is being replaced, or where there is no available external wall space and no ceiling space access. 03 Page Reference 56-57 Page Reference 54-55 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 9 SELECTION CHART Selecting the right fan is Easy Wall/Ceiling Fans ROOM TYPE Toilets Laundries - No Dryer Basement Offices These rooms require between 6 and 10 ACH Bathrooms Showers Ensuites These rooms require between 11 and 15 ACH Kitchens Laundries - With Dryer These rooms require between 15 and 20 ACH Thru Wall Fan Kits Room Size (m3) VA Lo-Carbon Pro-Series Classic Pro-Series Classic 1-5m3 LCS150 XFLP125 XF125 XPLP125 XP125 6-10m3 LCS150 XFLP125 XF125 XPLP125 XP125 11-15m3 LCS150 XFLP150 XF150 XPLP150 XP150 1-10m3 LCS150 XFLP150 XF150 XPLP150 XP150 11-15m3 LCS150 XFLP150 XF150 XPLP150 XP150 16-20m3 - XFLP150 XF150 XPLP150 XP150 21-30m3 - 1-5m3 LCS150 XFLP150 XF150 XPLP150 XP150 6-10m3 - XFLP150 XF150 XPLP150 XP150 11-20m3 - XFS230 XPS230 XF230 XPS230 3 Step Selection Guide 01 01 01 02 02 02 03 03 Select your required application, e.g. Bathrooms (11-15 air changes per hour). Calculate the volume of the room in cubic metres (m3) by multiplying the length x width x height E.g. 2.3m x 2.2m x 2.4m = 12.14m3 (Select a room volume 11-15m3). 10 HEAT/FAN/ LIGHT UNITS IN-LINE FAN KITS EXTRACT-A-LITE KITS WINDOW FANS THRU ROOF FAN KITS Pro-Series Pro-Series Classic Pro-Series Classic Pro-Series Classic Heat ‘n Vent 2 SFLP125 SF125 ELLP125 EL100 WF150 HYPER Heat ‘n Vent 2 SFLP125 SF125 ELLP125 EL125 WF150 HYPER Heat ‘n Vent 4 SFLP150 SF150 ELLP150 EL150 WF150 HYPER Heat ‘n Vent 2 SFLP150 SF150 ELLP125 EL150 WF150 HYPER Heat ‘n Vent 4 SFLP150 SF150 ELLP150 EL150 WF150 HYPER SFLP150 SF150 ELLP150 EL150 WF150 ULTRA WF230 ULTRA MFLP150 SFLP150 SF150 ELLP125 EL150 WF150 HYPER SFLP150 SF150 ELLP150 EL150 WF150 HYPER WF230 ULTRA MFLP150 03 Follow the 12m3 row across and select one of the fan kits available based on your mounting requirements (see top headings and photos). E.g. If you require a Thru Wall Kit then you can choose any of the XP150 or XPLP150 kits. Note: All selections are based on installed fan performance and maximum air change rates (figures in brackets show actual air changes stated if less than maximum). Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 11 Manrose PRO-SERIES wall/ceiling mounted fans xflp low profile models Square Models Duct Size Model No. Switching Method Performance 3 Order Code 125mm XFLP125SS Standard 36 l/s, 130m /hr FAN0589 125mm XFLP125ST Timer 36 l/s, 130m3/hr FAN0590 150mm XFLP150SS 150mm XFLP150ST Standard 3 FAN0594 3 FAN0595 87 l/s, 313m /hr Timer 87 l/s, 313m /hr Circular Models Duct Size Model No. Switching Method Performance Order Code 125mm XFLP125CS Standard 36 l/s, 130m3/hr FAN0604 125mm XFLP150CS 150mm 150mm Standard FAN0609 3 FAN0610 87 l/s, 313m /hr 87 l/s, 313m /hr Timer XFLP150CT FAN0605 3 36 l/s, 130m /hr Timer XFLP125CT 3 Safety extra low voltage (selv) models Duct Size Model No. 125mm XFLP125SLV 125mm 150mm Performance Order Code SELV 12V 36 l/s, 130m3/hr FAN0591 XFLP125CLV SELV 12V 36 l/s, 130m3/hr FAN0606 XFLP150SLV SELV 12V 87 l/s, 313m3/hr FAN0596 XFLP150CLV 150mm Switching Method SELV 12V 3 87 l/s, 313m /hr FAN0611 Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402). Duct Size Description: Square Order Code 125mm Satin Silver Fascia FAN2069 125mm Satin Silver Fascia FAN2068 125mm Chrome Fascia FAN0757 125mm Chrome Fascia FAN0755 150mm Satin Silver Fascia FAN2070 150mm Satin Silver Fascia FAN2071 150mm Chrome Fascia FAN0613 150mm Chrome Fascia FAN0598 • Unique low profile design enables these fans to be installed unobtrusively into any wall or ceiling. • These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. • Supported by a 5 year warranty. EA Order Code LB Description: Circular BAL Duct Size R ACCESSORIES Switching Options 1. Standard Model - operates from remote switch (not supplied). 3. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery. 12 GM OT O R 5 IN YEAR WARRANTY TECHNICAL DATA General information Models Circular Cut-Out Size XFLP125S 140mm - Using gib fixing clips supplied/included XFLP125C 140mm - Using gib fixing clips supplied/included XFLP150S 173mm - Using gib fixing clips supplied/included XFLP150C 173mm - Using gib fixing clips supplied/included DIMENSION INFORMATION (mm) Models A B C D XFLP125S 161 122 10 118 XFLP125C 165 122 10 118 XFLP150S 191 122 10 150 XFLP150C 198 122 10 150 Dimensions - XFLP A A A C D B TECHNICAL SPECIFICATION Models XFLP125 XFLP150 Power 220 - 240V (SELV models 12V) 220 - 240V (SELV models 12V) Fan Performance 36 l/s, 130m /hr 87 l/s, 313m3/hr Fan Wattage 20W 25W Maximum Pressure 35 Pa 60 Pa Fan Speed 2000 RPM 2400 RPM Sound Level 41 dB(A) 40 dB(A) Max. Operating Temp 50°C 50°C IP Rating IPX4 IPX4 Performance - XFLP125 3 Performance - XFLP150 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 13 Manrose CLASSIC WALL/CEILING MOUNTED FANS XF Models STANDARD Models Duct Size 100mm Model No. XF100S Switching Method Standard Performance Order Code 3 FAN0046 3 23 l/s, 85m /hr 100mm XF100P Pull Cord 23 l/s, 85m /hr FAN0047 100mm XF100T Timer 23 l/s, 85m3/hr FAN0048 3 125mm XF125S Standard 36 l/s, 130m /hr FAN0072 125mm XF125P Pull Cord 36 l/s, 130m3/hr FAN0074 3 125mm XF125T Timer 36 l/s, 130m /hr FAN0075 150mm XF150S Standard 87 l/s, 313m3/hr FAN0120 3 150mm XF150P Pull Cord 87 l/s, 313m /hr FAN0126 150mm XF150T Timer 87 l/s, 313m3/hr FAN0127 150mm XF150PIR PIR Control 3 87 l/s, 313m /hr Standard Model FAN0124 AUTO SHUTTER Models Duct Size Model No. Switching Method Performance Order Code 150mm XF150A Standard 87 l/s, 313m3/hr FAN0121 150mm XF150AP Pull Cord 87 l/s, 313m3/hr FAN0122 150mm XF150AT Timer 87 l/s, 313m3/hr FAN0123 Safety extra low voltage (selv) models Auto Shutter Model Order Code 100mm XF100LV SELV 12V 23 l/s, 85m3/hr FAN0044 3 125mm XF125LV SELV 12V 36 l/s, 130m /hr FAN0071 150mm XF150LV SELV 12V 87 l/s, 313m3/hr FAN0119 Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402). Safety Model (SELV) • Designed for wall or ceiling mounting, these models are efficient and easy to install. • These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. • Supported by a 5 year warranty. R Performance EA Switching Method LB Model No. BAL Duct Size Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. PIR Model - Motion sensor incorporated in fan. 6. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery 14 GM OT O R 5 IN YEAR WARRANTY TECHNICAL DATA GENERAL INFORMATION Models Circular Cut-Out Size XF100 112mm XF125 135mm XF150 160mm Please note: Fan cut out size is a nominal diameter. DIMENSION INFORMATION (mm) Dimensions - XF Models A B C D E XF100 155 98 74 27 155 XF125 168 118 74 27 168 XF150 200 148 74 27 200 XF150PIR 200 148 90 55 200 XF150A/AP 200 148 90 55 200 C A B D E TECHNICAL SPECIFICATION Models XF100 XF125 Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V) 3 220 - 240V (LV models 12V) Fan Performance 23/s, 85m /hr 36 l/s, 130m /hr 87 l/s, 313m3/hr Fan Wattage 20W 20W 25W Maximum Pressure 20 Pa 35 Pa 60 Pa Fan Speed 2400 RPM 2000 RPM 2400 RPM Sound Level 41 dB(A) 41 dB(A) 40 dB(A) Max. Operating Temp 50°C 50°C 50°C IP Rating IPX4 IPX4 IPX4 Performance - XF100 3 XF150 Performance - XF125 Performance - XF150 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 15 Manrose CLASSIC WALL/CEILING FANS XFS COMMERCIAL Models Duct Size Model No. Switching Method Performance 230mm 152 l/s, 550m3/hr 300mm 300mm XFS230S XFS300S XFS300S Standard Standard Standard Order Code FAN0374 3 FAN2040 3 FAN2040 306 l/s, 1100m /hr 306 l/s, 1100m /hr AUTO SHUTTER Models Commercial Models Duct Size Model No. Switching Method Performance Order Code 3 230mm XFS230A Standard 152 l/s, 550m /hr FAN0346 300mm XFS300A Standard 306 l/s, 1100m3/hr FAN2041 Auto Shutter Models Manrose Classic THRU WALL FAN KITS XPS COMMERCIAL Models Duct Size Model No. Switching Method Performance 230mm Standard 152 l/s, 550m3/hr 300mm XPS230S XPS300S Standard Order Code FAN0455 3 306 l/s, 1100m /hr FAN2042 AUTO SHUTTER Models Commercial Models Duct Size Model No. Switching Method Performance 230mm XPS230A Standard 300mm XPS300A Standard Order Code 152 l/s, 550m3/hr 3 306 l/s, 1100m /hr FAN0348 FAN2043 BAL LB EA R Auto Shutter Models GM OT O R 5 IN YEAR WARRANTY 16 TECHNICAL DATA GENERAL INFORMATION Models Fan Cut-Out Size Exterior Grille Duct Type Duct Length XFS230 265mm - - - XFS300 310mm - - - XPS230 265mm White Fixed Grille Aluminium Semi-Rigid 375mm XPS300 310mm White Fixed Grille Aluminium Semi-Rigid 375mm Please note: Fan cut out size is a nominal diameter. DIMENSION INFORMATION (mm) Models A B C D E F G H I XFS230 286 230 141 75 66 - - - - XFS300 362 300 156 81 75 - - - - XPS230 286 230 141 75 286 250 375 248 30 XPS300 362 300 156 81 350 230 375 298 50 Dimensions - XF230/300 Dimensions - XPS230/300 C C E A B E A G I H F D B A D TECHNICAL SPECIFICATION Models XFS230 XFS300 XPS230 XPS300 Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V Fan Performance 152 l/s, 550m³/hr 306 l/s, 1100m³/hr 152 l/s, 550m³/hr 306 l/s, 1100m³/hr Fan Wattage 45W 82W 45W 82W Maximum Pressure 50 Pa 60 Pa 50 Pa 60 Pa Fan Speed 1250 RPM 1300 RPM 1250 RPM 1300 RPM Sound Level 50 dB(A) 60 dB(A) 50 dB(A) 60 dB(A) Max. Operating Temp 50°C 50°C 50°C 50°C IP Rating IPX4 IPX4 IPX4 IPX4 Performance - XFS230 Performance - XFS300 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 17 WHISPERVENT CEILING FANS CENTRIFUGAL CEILING FAN MODELS Duct Size Model No. Colour Performance Order Code 100mm WVC100W White 63 l/s, 225m3/hr FAN0884 100mm WVC100S Stainless 63 l/s, 225m3/hr FAN0885 150mm WVC150S White 100 l/s, 360m3/hr FAN2465 • • • • Designed for apartments where space is limited, these ceiling mounted fans can be installed in confined spaces. The centrifugal fan design assists‘whisper quiet’ operation. Reliable long lasting ball bearinng motor Supported by a 3 year warranty. NEW Simx Whispervent 150 - White Simx Whispervent 100 - Silver 3 YEAR WARRANTY Switching Options 1. Standard Model - operates from remote switch (not supplied). 18 TECHNICAL DATA DIMENSION INFORMATION (mm) Models A B C D WhisperVent 100 240 290 172 98 WhisperVent 150 310 330 370 37 Dimensions - WhisperVent 100 E F 184 30 Dimensions - WhisperVent 150 D A B C C C A B E D TECHNICAL SPECIFICATION Models WhisperVent 100 WhisperVent 150 Power 220 - 240V 220 - 240V 3 Fan Performance 63 l/s, 225m /hr 100 l/s, 360m3/hr Fan Wattage 30W 42W Maximum Pressure 105 Pa 145 Pa Fan Speed 2500 RPM 2500 RPM Sound Level 38 dB(A) 44 dB(A) Max. Operating Temp 40oC 40oC IP Rating IPX4 IPX4 Performance - WhisperVent 100 Performance - WhisperVent 150 Airflow (m³/hr) 0 50 100 150 200 250 300 350 400 160 50 100 150 200 250 140 120 Pressure (Pa) 100 80 60 40 20 15 30 45 60 75 0 0 20 40 60 80 100 120 Airflow (l/s) Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 19 Manrose CLASSIC Multi-Vent Fans FLUSH FITTING RANGE Duct Size Model No. Switching Method Performance @ Speed 3 Order Code 100mm FFCF234S Standard 65 l/s, 234m3/hr FAN0038 100mm FFCF234T Timer 65 l/s, 234m3/hr FAN0499 100mm FFCF234PIR PIR 65 l/s, 234m3/hr FAN0501 SURFACE MOUNT RANGE Flush Fitting Range Duct Size Model No. Switching Method Performance @ Speed 3 Order Code 100mm SMCF234S Standard 65 l/s, 234m3/hr FAN0504 100mm SMCF234T Timer 65 l/s, 234m3/hr FAN0505 • • • Designed for apartments where space is limited, with a choice of wall or ceiling mounted system. These Models include centrifugal fans with a choice of three in-built speed settings depending on the performance required. Supported by a 2 year warranty. Manrose CLASSIC WALL FAN CF CENTRIFUGAL MODELS Duct Size Model No. Switching Method Performance @ Speed 1 Order Code 100mm CF200S Standard 31 l/s, 110m3/hr FAN0041 100mm CF200TP Timer 31 l/s, 110m3/hr FAN0042 CF Centrifugal Model • Designed to move air over long distances. • The centrifugal fan design provides efficient airflow and quiet operation. • Supported by a 2 year warranty. 2 YEAR WARRANTY 1. Standard Model - operates from remote switch (not supplied). 3. PIR Model - Motion sensor incorporated in fan. Range up to 5 metres. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery. 20 TECHNICAL DATA DIMENSION INFORMATION (mm) Models A B C D E F G H Multi-Vent FFCF234 91 96 141 250 15 155 210 - Multi-Vent SMCF234 312 250 15 119.5 22.5 63 249 - CF200 65 185 260 45 98 90 135 65 Dimensions - CF200 Dimensions - Multi-Vent (Flush Fitting) B Dimensions - Multi-Vent (Surface Mount) B C A G E E A C F C A G H D D E F G G D D B TECHNICAL SPECIFICATION Models Multi-Vent CF200 1 Speed 2 Speed 3 Speed Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V Fan Performance 28 l/s, 100m3/hr 45 l/s, 162m3/hr 65 l/s, 234m3/hr 31 l/s, 110m3/hr Fan Wattage 40W 80W 110W 45W Maximum Pressure 140 Pa 165 Pa 180 Pa 120 Pa Fan Speed 950 RPM 1500 RPM 1850 RPM 1400 RPM Sound Level 37 dB(A) 51 dB(A) 56 dB(A) 45 dB(A) Max. Operating Temp 50°C 50°C 50°C 50°C IP Rating IPX4 IPX4 IPX4 IPX4 Performance - CF200 Performance - Multi-Vent Volume m3/hr 0 54 108 162 216 270 60 75 200 180 160 Static Pressure Pa 140 120 100 2 80 3 1 60 40 20 0 0 15 30 45 Volume l/sec NOTE 1, 2, 3 refer to speed settings controlled by internal switch (not consumer adjustable). Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 21 Manrose Pro-Series THRU WALL mounted FAN kits XPLP Low Profile Models STANDARD Models Duct Size Model No. 125mm XPLP125SS Switching Method Performance Order Code Standard 36 l/s, 130m3/hr FAN0614 3 125mm XPLP125ST Timer 36 l/s, 130m /hr FAN0615 150mm XPLP150SS Standard 87 l/s, 313m3/hr FAN0621 150mm XPLP150ST Timer 3 87 l/s, 313m /hr FAN0623 Standard Models Safety extra low voltage (selv) models Duct Size Model No. Switching Method Performance Order Code 125mm XPLP125SLV SELV 12V 36 l/s, 130m3/hr FAN0620 125mm XPLP125CLV SELV 12V 36 l/s, 130m3/hr FAN0735 3 150mm XPLP150SLV SELV 12V 87 l/s, 313m /hr FAN0732 150mm XPLP150CLV SELV 12V 87 l/s, 313m3/hr FAN0738 Low Voltage Models Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402). ACCESSORIES Satin Silver Fascia FAN2068 125mm Chrome Fascia FAN0755 150mm Satin Silver Fascia FAN2071 150mm Chrome Fascia FAN0598 Duct Size Description - Circular Order Code 125mm Satin Silver Fascia FAN2069 125mm Chrome Fascia FAN0757 150mm Satin Silver Fascia FAN2070 150mm Chrome Fascia FAN0613 • • • The unique Low Profile design enables these fans to be installed unobtrusively into any wall (requires a minimum wall cavity of 110mm). These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty. Accessories - Square Accessories - Circular Fascia R 125mm EA Order Code LB Description - Square BAL Duct Size Note 1. Standard Model - operates from remote switch (not supplied). 3. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires permanent phase and switched phase. NOTE: All fan flow rates quoted are free air delivery. 22 GM OT O R 5 IN YEAR WARRANTY Technical data GENERAL INFORMATION Models Fan Cut-Out Size Exterior Grille Duct Type Duct Length XPLP125 140mm White Gravity Shutter Aluminium Semi-Rigid 375mm XPLP150 173mm White Gravity Shutter Aluminium Semi-Rigid 375mm Please note: Fan cut out size is a nominal diameter. DIMENSION INFORMATION (mm) Models A B C D E F G H I XPLP125 161 118 128 10 160 125 375 123 30 XPLP150 191 150 132 10 174 150 375 148 30 Dimensions - XPLP I E G H F B A C D TECHNICAL SPECIFICATION Models XPLP125 XPLP150 Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V) Fan Performance 36 l/s, 130m /hr 87 l/s, 313m3/hr Fan Wattage 20W 25W Maximum Pressure 35 Pa 60 Pa Fan Speed 2000 RPM 2400 RPM Sound Level 41 dB(A) 40 dB(A) Max. Operating Temp 50°C 50°C IP Rating IPX4 IPX4 Performance - XPLP125 3 Performance - XPLP150 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 23 Manrose CLASSIC THRU WALL MOUNTED FAN KITS XP Models STANDARD Models Duct Size Model No. Switching Method Performance Order Code 100mm XP100S Standard 23 l/s, 85m3/hr FAN0053 100mm 100mm 125mm XP100P XP100T XP125S 3 Pull Cord 23 l/s, 85m /hr FAN0054 3 Timer 23 l/s, 85m /hr Standard FAN0055 3 FAN0080 3 36 l/s, 130m /hr 125mm XP125P Pull Cord 36 l/s, 130m /hr FAN0082 125mm XP125T Timer 36 l/s, 130m3/hr FAN0083 150mm 150mm 150mm XP150S XP150P XP150T Standard 3 FAN0135 3 FAN0140 3 FAN0141 87 l/s, 313m /hr Pull Cord 87 l/s, 313m /hr Timer 87 l/s, 313m /hr Standard Models AUTO SHUTTER Models Order Code 150mm XP150A Standard 87 l/s, 313m3/hr FAN0136 150mm 150mm XP150AP XP150AT Pull Cord Timer 3 FAN0137 3 FAN0138 87 l/s, 313m /hr 87 l/s, 313m /hr Safety extra low voltage (selv) models Duct Size Model No. Switching Method Performance Order Code 100mm XP100LV SELV 12V 25 l/s, 85m3/hr FAN0409 3 125mm XP125LV SELV 12V 36 l/s, 130m /hr FAN0410 150mm XP150LV SELV 12V 87 l/s, 313m3/hr FAN0411 Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402). • • • These fans are designed to be ducted straight through an exterior wall and are efficient and easy to install. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty. Auto Shutter Models Low Voltage Models R Performance EA Switching Method LB Model No. BAL Duct Size Note 1. Standard Model - operates from remote switch (not supplied). 3. Pull Cord Model - Integral pull cord switch on fan. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery. 24 GM OT O R 5 IN YEAR WARRANTY Technical data GENERAL INFORMATION Models Fan Cut-Out Size Exterior Grille Duct Type Duct Length XP100 112mm Grey Gravity Shutter Aluminium Semi-Rigid 375mm XP125 135mm Grey Gravity Shutter Aluminium Semi-Rigid 375mm XP150 160mm Grey Gravity Shutter Aluminium Semi-Rigid 375mm Please note: Fan cut out size is a nominal diameter. DIMENSION INFORMATION (mm) Models A B C D E F G H I XP100 155 98 74 27 138 100 375 98 30 XP125 168 118 74 27 160 125 375 123 30 XP150 200 148 74 27 174 150 375 148 30 XP150A 200 148 90 55 174 150 375 148 30 Dimensions - XP C I E D G H F B A TECHNICAL SPECIFICATION Models XP100 XP125 XP150 Power 220 - 240V (SELV models 12V) 220 - 240V (SELV models 12V) 220 - 240V (SELV models 12V) Fan Performance 23 l/s, 85m³/hr 36 l/s, 130m³/hr 87 l/s, 313m³/hr Fan Wattage 20W 20W 25W Maximum Pressure 20 Pa 35 Pa 60 Pa Fan Speed 2400 RPM 2000 RPM 2400 RPM Sound Level 41 dB(A) 41 dB(A) 40 dB(A) Max. Operating Temp 50°C 50°C 50°C IP Rating IPX4 IPX4 IPX4 Performance - XP100 Performance - XP125 Performance - XP150 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 25 Manrose CLASSIC WINDOW MOUNTED FANS WF Models STANDARD Models Duct Size Model No. Switching Method Performance Order Code 100mm WF100P Pull Cord 23 l/s, 85m3/hr FAN0021 100mm WF100PLV Low Voltage 23 l/s, 85m3/hr FAN0452 Manual SHUTTER Models Standard Models Duct Size Model No. Switching Method Performance Order Code 150mm WF150MP Pull Cord 87 l/s, 313m3/hr FAN0110 150mm WF150MPLV SELV 12 87 l/s, 313m3/hr FAN0355 Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402). AUTO SHUTTER Models Duct Size Model No. Switching Method Performance Order Code 150mm WF150AP Pull Cord 87 l/s, 313m3/hr FAN0107 150mm WF150APT Pull Cord Timer 87 l/s, 313m3/hr FAN0109 Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are Supported by a 5 year warranty. Auto Shutter Models BAL LB EA R • • GM OT O R 5 IN YEAR WARRANTY Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. Manual Pull cord - Pull cord operates fan and manual shutters. 6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery. 26 Technical data GENERAL INFORMATION Models Glass Cut-Out Size WF100 115mm - 155mm WF150 165mm - 190mm Please note: Glass cut out size is a nominal diameter for a circular cut-out. DIMENSION INFORMATION (mm) Models A B C Dimensions - WF B D WF100 163 90 30 163 WF150 203 118 23 203 A C D TECHNICAL SPECIFICATION Models WF100 WF150 Power 220 - 240V 220 - 240V (SELV models 12V) Fan Performance 23 l/s, 85m³/hr 87 l/s, 313m³/hr Fan Wattage 20W 25W Maximum Pressure 20 Pa 60 Pa Fan Speed 2400 RPM 2400 RPM Sound Level 41 dB(A) 40 dB(A) Max. Operating Temp 50oC 50oC IP Rating IPX4 IPX4 Performance - WF100 Performance - WF150 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 27 Manrose CLASSIC WINDOW COMMERCIAL FANS WF Commercial MODELS Standard Models Duct Size Model No. Switching Method Performance Order Code 230mm WF230P Pull Cord 152 l/s, 550m3/hr FAN0148 300mm WF300P Pull Cord 306 l/s, 1100m3/hr FAN0481 AUTO SHUTTER Models Standard Larger Models Duct Size Model No. Switching Method Performance Order Code 230mm WF230AP Pull Cord 152 l/s, 550m3/hr FAN0146 300mm WF300A Standard 306 l/s, 1100m3/hr FAN0482 • • Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are Supported by a 5 year warranty. Auto Shutter Models Manrose CLASSIC WINDOW COMMERCIAL FANS COM Commercial Models Duct Size Model No. Switching Method Performance Order Code 230mm COM230A Standard 185 l/s, 670m3/hr FAN0519 230mm COM230MP Pull Cord 185 l/s, 670m3/hr FAN0518 300mm COM300A Standard 280 l/s,1020m3/hr FAN0521 300mm COM300MP Pull Cord 280 l/s,1020m3/hr FAN0520 Commercial Auto Shutter Models BAL LB EA R • Designed for commercial applications such as pubs, restaurants, hotels, shops etc. • These axial fans include ball bearing motors to prolong the life of the motor. • Supported by a 5 year warranty. GM OT O R 5 IN YEAR WARRANTY Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. Manual Pull cord - Pull cord operates fan and manual shutters. 6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery. 28 Technical data GENERAL INFORMATION Models Glass Cut-Out Size WF230 255mm - 270mm WF300 310mm - 345mm COM230 255mm - 270mm COM300 310mm - 345mm Dimensions - WF230/300 C B Please note: Glass cut out size is a nominal diameter for a circular cut-out. A DIMENSION INFORMATION (mm) D E Dimensions - COM230/300 Models A B C D E WF230 286 286 4-32 112 25 WF300 362 362 4-32 133 29 COM230 286 125 25 154 - COM300 362 145 25 170 - A B A D C TECHNICAL SPECIFICATION Models WF230 Power 220 - 240V WF300 COM230 220 - 240V 3 COM300 220 - 240V 3 220 - 240V 3 Fan Performance 152 l/s, 550m /hr 306 l/s, 1100m /hr 185 l/s, 670m /hr 280 l/s, 1020m3/hr Fan Wattage 45W 82W 45W 82W Maximum Pressure 50 Pa 60 Pa 50 Pa 60 Pa Fan Speed 1250 RPM 1300 RPM 1600 RPM 1300 RPM Sound Level 50 dB(A) 60 dB(A) 53 dB(A) 60 dB(A) Max. Operating Temp 50°C 50°C 50°C 50°C Performance - WF230 Volume m 3/hr 0 250 500 750 Performance - WF300 Performance - COM230 Volume m 3/hr 300 600 900 1200 1500 0 83 168 250 333 416 Performance - COM300 55 Static Pressure Pa Static Pressure Pa 55 0 40 40 25 25 0 0 0 70 140 Volume l/sec 210 Volume l/sec Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 29 Manrose PRO-SERIES HEAT/FAN/LIGHT KITS Heat ‘n Vent Models Duct Size Model No. Performance Order Code 125mm Heat ‘n Vent 4 60 l/s, 216m3/hr FAN0995 125mm Heat ‘n Vent 2 50 l/s, 180m3/hr FAN0940 ACCESSORIES Pro-Series Heat ‘n Vent 4 Duct Size Description Order Code 125mm Heat ‘n Vent 4 Silver Fascia FAN1015 125mm Heat ‘n Vent 2 Silver Fascia FAN1014 275W Heat Lamp LHT0081 50W Halogen GU10 lamp LHT0140 Pro-Series Heat ‘n Vent 2 • • • With a 40% increase in performance* these systems meet the demands of larger bathrooms and the stylish fascia blends into the decor. These high efficiency centrifugal fans incorporate a unique anti-condensate design feature. Supported by a 5 year warranty. Manrose CLASSIC Heat/FAN/LIGHT KIT Heat ‘n Vent 2 Duct Size Model No. Performance Order Code 100mm 35 l/s, 126m3/hr FAN2162 Heat ‘n Vent 2 • This system delivers instant heat combined with ventilation and soft lighting to create a comfort area in small bathrooms. • Supported by a 5 year warranty. Classic Heat ‘n Vent 2 Manrose CLASSIC Heat/LIGHT KIT 2 Heat ‘n LIGHT FAN2200 2 Heat ‘n Light (excludes fan) 2 Heat ‘n Light BAL • This system provides instant heat and additional lighting. • For a complete bathroom solution an extraction fan can be added. • Supported by a 5 year warranty. R 100mm EA Order Code LB Duct Size Description GM OT O R 5 IN YEAR WARRANTY Switching Options 1. Standard Model - operates from remote switch (not supplied). *Increase in performance is based on the comparison to the previous models. 30 NOTE: All fan flow rates quoted with 3 metres of duct, one bend and one external grille (normal installation). Technical data GENERAL INFORMATION Models Cut-Out Size Exterior Grille Duct Type Duct Length PS Heat ‘n Vent 4 300mm x 300mm White Eggcrate Aluminium 3m supplied (you can add up to 3m extra duct) PS Heat ‘n Vent 2 390mm x 210mm White Eggcrate Aluminium 3m supplied (you can add up to 3m extra duct) Classic Heat ‘n Vent 2 390mm x 220mm White Eggcrate Aluminium 3m supplied (you can add up to 3m extra duct) Classic Heat ‘n Light - - - 390mm x 220mm DIMENSION INFORMATION (mm) Models A B C D PS Heat ‘n Vent 4 338 338 170 120 PS Heat ‘n Vent 2 435 260 185 120 Heat ‘n Vent 450 250 195 100 Heat ‘n Light 450 250 195 100 Dimensions - PS Heat ‘n Vent 2 Dimensions - PS Heat ‘n Vent 4 Dimensions - Classic Heat ‘n Vent D C B A Dimensions - Classic 2 Heat ‘n Light D D C C C B B B A A TECHNICAL SPECIFICATION Models PS Heat ‘n Vent 4 PS Heat ‘n Vent 2 Heat ‘n Vent 2 2 Heat ‘n Light Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V Fan Centrifugal Centrifugal Centrifugal - Fan Performance 60 l/s, 216m³/hr 50 l/s, 180m³/hr 35 l/s, 126m³/hr - Heat Lamps 4 x 275W 2 x 275W 2 x 275W 2 x 275W Light GU10 Halogen GU10 Halogen GLES GLES Total Wattage 1180W 635W 670W 650W Light Wattage 50W 50W 100W 100W Switch Plate 4 sw. (supplied) 3 sw. (supplied) 3 sw. (supplied) 2 sw. (supplied) Warranty 5 Years 5 Years 5 Years 5 Years Performance Graph Icon Key 36 72 108 144 03 180 02 216 252 01 288 01 Pro-Series Heat ‘n Vent 4 02 Pro-Series Heat ‘n Vent 2 03 Classic Heat 'n Vent 2 Note: Performance tested in free air. 70 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 31 PRO-SERIES IN-LINE MOUNTED FAN KITS MIXFLO™ Shower Fan Models Duct Size Model No. Switching Method Performance Order Code 100mm Standard 69 l/s, 250m3/hr FAN2049 150mm MFLP125S MFLP150S Standard Standard 3 89 l/s, 320m /hr 3 166 l/s, 597m /hr FAN2050 FAN2051 MKLP150 BAL LB EA • These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. • Supported by a 5 year warranty. R 125mm MFLP100S Grille Cut-Out Interior Grille Exterior Grille MFLP100 115mm White Low Profile White Low Profile Unilok Nude 6m supplied (you can add up to 6m extra duct) MFLP125 140mm White Low Profile White Low Profile Unilok Nude 6m supplied (you can add up to 6m extra duct) MFLP150 160mm White Low Profile White Low Profile Unilok Nude 6m supplied (you can add up to 6m extra duct) Please note: Grille cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). 32 OT O R YEAR WARRANTY GENERAL INFORMATION (KITS) Models GM 5 IN Duct Type Duct Length Technical data Dimension INFORMATION (mm) Models A B C D E F G MF100 98 182 315 100 100 168 27 MF125 122 182 350 100 100 168 60 MF150 147 209 360 130 115 195 55 Dimensions - MF TECHNICAL SPECIFICATION Model No Size (mm) MF100 100 MF125 125 MF150 150 RPM Watts Maximum Airflow (m³/hr) Maximum Pressure (Pa) 2300 40 250 180 1700 18 190 120 2300 40 320 220 1700 18 260 160 2700 70 597 300 2000 60 330 240 Performance - MF100 50 100 150 IP Rating X4 45 43 X4 45 47 X4 60 Performance - MF150 Airflow (m3/hr) 200 250 300 0 50 100 150 Airflow (m3/hr) 200 250 300 0 350 250 200 100 200 300 400 500 600 700 350 180 300 200 160 250 140 120 100 80 Pressure (Pa) 150 Pressure (Pa) Pressure (Pa) Max Operating Temp °C 40 Performance - MF125 Airflow (m3/hr) 0 Lp dB(A) 3m* 100 200 150 100 60 50 40 50 20 0 0 0 20 40 60 0 0 80 20 Airflow (L/s) 40 60 80 Airflow (L/s) 100 0 50 100 150 200 Airflow (L/s) * Lp dB(A) @ 3 metres - sound pressure based on the high speed for each fan. SOUND POWER LEVEL (high speed) Model No Sound Power Levels Lw (dB) Octave band centre frequency in Hz LwA dB(A) 125 250 500 1000 2000 4000 8000 MF100 50 56 58 58 52 47 37 61 MF125 52 59 60 60 56 49 41 63.5 MF150 58 66 65 63 62 54 46 67.5 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 33 Manrose PRO-SERIES IN-LINE FANS KITS SFLP Shower Fan Models Model No. Switching Method Fan Type Performance Order Code 125mm SFLP125S Standard Ctr’fgl 39 l/s, 140m³/hr FAN0616 125mm SFLP125T Timer Ctr’fgl 39 l/s, 140m³/hr FAN0617 150mm SFLP150S Standard Whisper 94 l/s, 340m³/hr FAN0618 150mm SFLP150T Timer Whisper 94 l/s, 340m³/hr FAN0619 SFLP150 BAL LB EA R Duct Size GM OT O R 5 IN YEAR WARRANTY • These high efficiency in-line fans are designed to provide higher levels of extraction for today’s larger bathrooms. • Supported by a 5 year warranty. General INFORMATION Models Grille Cut-Out Interior Grille Exterior Grille Duct Type Length of Duct included SFLP125 140mm White Low Profile White Low Profile Flexible Aluminium 4m supplied (can be extended up to 6m) SFLP150 160mm White Low Profile White Low Profile Flexible PVC 5m supplied (can be extended up to 12m) Please note: Grille cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include 34 a fixed 7 minute timer. Both require three wires: permanent phase, switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used. Technical data Dimension INFORMATION (mm) Models A B C D E SFLP125 155 125 125 195 258 SFLP150 200 143 170 185 - Dimensions - SFLP125 Dimensions - SFLP150 C A B A C D B D E TECHNICAL SPECIFICATION Models SFLP125 SFLP150 Fan CFD225 WhisperVent Power 220 - 240V 220 - 240V Fan Performance 39 l/s, 140m³/hr 94 l/s, 340m³/hr Fan Wattage 20W 46W Maximum Pressure 120 Pa 160 Pa Fan Speed 1400 RPM 2750 RPM Sound Level 45 dB(A) 38 dB(A) Max. Operating Temp 50°C 80°C IP Rating IPX4 IPX2 Performance - SFLP125 Performance - SFLP150 36 72 108 144 180 216 252 70 288 324 360 90 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 35 Manrose CLASSIC IN-LINE FAN KITS SF Shower Fan Models Model No. Switching Method Fan Type Performance Order Code 100mm SF100S Standard Axial 23 l/s, 85m3/hr FAN0017 100mm SF100T Timer Axial 23 l/s, 85m3/hr FAN0018 100mm SF200S Standard Ctr’fgl 31 l/s, 110m3/hr FAN0328 100mm SF200T Timer Ctr’fgl 31 l/s, 110m3/hr FAN0329 125mm SF125S Standard Axial 36 l/s, 130m3/hr FAN0064 125mm SF125T Timer Axial 36 l/s, 130m3/hr FAN0065 150mm SF150S Standard Axial 87 l/s, 320m3/hr FAN0101 150mm SF150T Timer Axial 87 l/s, 320m3/hr FAN0102 SF150 Shower Fan Kit • • • BAL LB EA R Duct Size GM YEAR WARRANTY With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from source. These fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty. GENERAL INFORMATION Duct Type Models Grille Cut-Out Interior Grille Exterior Grille SF100 115mm White Circular White Fixed Louvre Flexible PVC 3m supplied (should not be extended) SF200 115mm White Circular White Fixed Louvre Flexible Alum 3m supplied (can be extended up to 6m) SF125 140mm White Circular White Fixed Louvre Flexible PVC 4m supplied (should not be extended) SF150 160mm White Circular White Fixed Louvre Flexible PVC 5m supplied (can be extended up to 12m) Length of Duct included Please note: Grille cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). a fixed 7 minute timer. Both require: permanent phase and switched phase. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include NOTE: All fan flow rates quoted are free air delivery. 36 OT O R 5 IN Performance will be affected by the length of ducting used. Technical data DIMENSION INFORMATION (mm) Models A B C D E SF100 130 155 90 100 27 SF200 155 100 100 195 258 SF125 150 155 99 118 27 SF150 187 153 109 150 27 TECHNICAL SPECIFICATION Models SF100 SF200 SF125 SF150 Fan ID100 CFD200 ID125 Hyper Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V Fan Performance 23 l/s, 85m³/hr 31 l/s, 110m³/hr 36 l/s, 130m³/hr 89 l/s, 320m³/hr Fan Wattage 20W 20W 20W 38W Maximum Pressure 20 Pa 120 Pa 35 Pa 135 Pa Fan Speed 2400 RPM 1400 RPM 2000 RPM 2650 RPM Sound Level 41 dB(A) 45 dB(A) 41 dB(A) 46 dB(A) Max Operating Temp 50°C 50°C 50°C 70°C IP Rating IPX4 IPX4 IPX4 IPX2 Performance - SF100 Performance - SF125 Dimensions - SF100/SF125/150 C D A E B Dimensions - SF200 B A C D E Performance - SF200 Performance - SF150 Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 37 Manrose PRO-SERIES IN-LINE FAN/LIGHT KITS ELLP Extract-a-lite Low Profile Models Duct Size Model No. Switching Method Performance Order Code 125mm ELLP125WS - Wht Standard 39 l/s, 140m3/hr FAN2029 125mm ELLP125WT - Wht Timer 39 l/s, 140m3/hr FAN2031 125mm 125mm ELLP125SS - Slv ELLP125ST - Slv Standard Timer 3 FAN2030 3 FAN2032 3 39 l/s, 140m /hr 39 l/s, 140m /hr 150mm ELLP150WS - Wht Standard 94 l/s, 340m /hr FAN2033 150mm ELLP150WT - Wht Timer* 94 l/s, 340m3/hr FAN2035 150mm 150mm ELLP150SS - Slv ELLP150ST - Slv Standard Timer* 3 FAN2034 3 FAN2036 94 l/s, 340m /hr 94 l/s, 340m /hr ELLP125SW * Includes a 7 minute fixed timer These high efficiency in-line fans are designed to provide higher levels of extraction for larger bathrooms and include a stylish downlight. White or satin silver finish available to complement your bathroom decor. Electronic Transformer included in the kit to operate the 12V downlight. Supported by a 5 year warranty. LB EA R ELLP150SS BAL • • • • ACCESSORIES GM OT O R 5 IN YEAR WARRANTY Duct Size Description Order Code 125mm Pro-Series ELLP Diffuser White incl lamp DCT1519 125mm Pro-Series ELLP Diffuser Silver incl lamp DCT1520 150mm Pro-Series ELLP Diffuser White incl lamp DCT1521 150mm Pro-Series ELLP Diffuser Silver incl lamp DCT1522 12V 35-50W Dichroic lamp with 60Ëš angle beam FAN0431 Electronic Transformer 12VAC 50kHz FAN2101 125mm ELLP Diffusers GENERAL INFORMATION Models Diffuser Cut-Out Interior Exterior Grille Duct Type Length of Duct included ELLP125W 140mm White Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (you can add up to 6m extra duct) ELLP125SS 140mm Satin Silver Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (you can add up to 6m extra duct) ELLP150W White Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (you can add up to 6m extra duct) Satin Silver Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (can be extended up to 12m) 165mm ELLP150SS 165mm Please note: Diffuser cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include 38 a fixed 7 minute timer. Both require: permanent phase, and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used. Technical data DIMENSION INFORMATION (mm) Models A B C D E F G H ELLP125 155 125 125 195 258 165 80 110 ELLP150 200 143 170 185 - 200 80 148 Dimensions - ELLP125 Fan Dimension - ELLP150 Fan Dimensions - ELLP Extract-a-lite Diffuser C A B A C D H B G D F E TECHNICAL SPECIFICATION Models ELLP125 ELLP150 Fan CFD225 WhisperVent Power 220 - 240V 220 - 240V Fan Performance 39 l/s, 140m³/hr 94 l/s, 340m³/hr Fan Wattage 20W 46W Maximum Pressure 120 Pa 160 Pa Fan Speed 1400 RPM 2750 RPM Light 12V 50W Halogen 12V 50W Halogen Total Wattage 99W 96W Sound Level 45 dB(A) 38 dB(A) Max. Operating Temp 50°C 80°C IP Rating IPX4 IPX2 Performance - ELLP125 Performance - ELLP150 36 72 108 144 180 216 252 70 288 324 360 90 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 39 Manrose CLASSIC IN-LINE FAN/LIGHT KITS EL Extract-a-lite Models EL100S Standard 100mm EL100T 125mm Timer EL125S Standard 31 l/s, 110m3/hr FAN0420 3 FAN0438 3 FAN2037 3 31 l/s, 110m /hr 36 l/s, 130m /hr 125mm EL125T Timer 36 l/s, 130m /hr FAN2038 150mm EL150S Standard 89 l/s, 320m3/hr FAN0803 150mm EL150T Timer* 89 l/s, 320m3/hr FAN0804 EL150S R 100mm Order Code EA Switching Method Performance LB Model No. BAL Duct Size OT O R YEAR WARRANTY * Includes a 7 minute fixed timer. • • • • GM 5 IN The fan is mounted in the ceiling space, and is therefore able to draw steam directly from source, while at the same time providing spot lighting within your bathroom. These fans have been upgraded with ball bearing motors to prolong the life of the motor. Electronic Transformer included in the kit to operate the 12V downlight. Supported by a 5 year warranty. ACCESSORIES EL Diffuser white incl lamp DCT0360 100mm EL Diffuser chrome incl lamp DCT0362 125mm EL Diffuser white incl lamp DCT2121 125mm EL Diffuser chrome incl lamp DCT2120 150mm EL Diffuser white incl lamp DCT1169 150mm EL Diffuser chrome incl lamp DCT1171 100mm Accessory chrome bezel - Extract-a-lite DCT0366 125mm Accessory chrome bezel - Extract-a-lite FAN2076 150mm Accessory chrome bezel - Extract-a-lite FAN0827 12V 35-50W Dichroic lamp with 60Ëš angle beam FAN0431 Electronic Transformer 12VAC 50kHz 125mm EL Diffusers R 100mm EA Order Code LB Description BAL Duct Size GM OT O R 5 IN YEAR WARRANTY FAN2101 GENERAL INFORMATION Models Diffuser Cut-Out Interior Exterior Grille Duct Type Length of Duct included EL100 115mm White Extract-a-lite incl light White Eggcrate Flexible PVC 3m supplied (should not be extended) EL125 145mm White Extract-a-lite incl light White Eggcrate Flexible PVC 4m supplied (should not be extended) EL150 165mm White Extract-a-lite incl light White Eggcrate Flexible PVC 5m supplied (you can add up to 12m extra duct) Please note: Diffuser cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models 40 include a fixed 7 minute timer. Both require: permanent phase and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used. Technical data DIMENSION INFORMATION (mm) Models A B C D E F G H EL100 130 155 90 100 27 140 74 98 EL125 150 155 99 118 27 170 74 118 EL150 200 143 170 185 200 74 148 Dimensions - EL125 Dimensions - EL100 Dimensions - EL150 Fan A B C D C A C D A B E B D E TECHNICAL SPECIFICATION Models EL100 EL125 EL150 Fan CFD200 ID125 Hyper Power 220 - 240V 220 - 240V 220 - 240V Fan Performance 31 l/s, 110m3/hr 36 l/s, 130m3/hr 89 l/s, 320m3/hr Fan Wattage 20W 25W 38W Maximum Pressure 120 Pa 35 Pa 135 Pa Fan Speed 1400 RPM 2000 RPM 2650 RPM Light 12V 50W Halogen 12V 50W Halogen 12V 50W Halogen Total Wattage 70W 75W 88W Sound Level 45 dB(A) 41 dB(A) 46 dB(A) Max. Operating Temp 40°C 40°C 70°C IP Rating IPX4 IPX4 IPX2 Performance - EL100 Performance - EL125 Dimensions - EL Extract-a-lite Diffuser H G F Performance - EL150 36 72 108 144 180 216 252 70 288 324 360 90 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 41 Pro-Series IN-LINE MIXED FLOW FANS MIXFLO™ Fan Models Duct Size Model No. Switching Method Speed Setting Performance @ High Speed Order Code 100mm MF100S Standard 2 Speed 69 l/s, 250m3/hr FAN1004 100mm MF100T Timer 2 Speed 69 l/s, 250m3/hr FAN2124 100mm MF100PL Plug & Lead 2 Speed 69 l/s, 250m3/hr FAN1050 125mm MF125S Standard 2 Speed 89 l/s, 320m3/hr FAN1005 125mm MF125T Timer 2 Speed 89 l/s, 320m3/hr FAN2125 3 125mm MF125PL Plug & Lead 2 Speed 89 l/s, 320m /hr FAN1051 150mm MF150S Standard 2 Speed 166 l/s, 597m3/hr FAN1006 150mm MF150T Timer 2 Speed 166 l/s, 597m3/hr FAN2126 3 150mm MF150PL Plug & Lead 2 Speed 166 l/s, 597m /hr FAN1048 200mm MF200S Standard 3 Speed 272 l/s, 980m3/hr FAN1007 200mm MF200T Timer 2 Speed 272 l/s, 980m3/hr FAN2127 200mm MF200PL Plug & Lead 3 Speed 272 l/s, 980m3/hr FAN1053 • These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. • Supported by a four year warranty or 30,000 continuous hours. Dimension information (mm) Dimensions - MF Models A B C D E F G MF100 98 182 315 100 100 168 27 MF125 122 182 350 100 100 168 60 MF150 147 209 360 130 115 195 55 MF200 197 244 354 142 140 230 50 Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery. 42 Mixflow 150mm Standard Model 4 YEAR WARRANTY Technical data technical specification 230V/50Hz/1Φ Motor Input (W) Max Temp (ºC) Sound Pressure Level (dBA@3m) 2300 0.40 45 40 1700 0.18 45 33 2300 0.40 45 43 1700 0.18 45 36 2700 0.70 60 47 2000 0.60 60 40 2700 0.85 60 48 2350 0.60 60 45 2000 0.45 60 41 Speed (rev/ min) Model No. MF100 MF125 MF150 MF200 Performance - MF100 SOUND POWER LEVEL (high speed) 125 250 500 1000 2000 4000 8000 MF100 50 56 58 58 52 47 37 MF125 52 59 60 60 56 49 41 MF150 58 66 65 63 62 54 46 MF200 65 69 64 63 62 60 48 Performance - MF125 Airflow (m3/hr) 0 50 100 Sound Power Levels LwA (dB) Octave band centre frequency in Hz Model No. 150 Airflow (m3/hr) 200 250 300 0 50 100 150 200 250 300 350 250 200 180 200 160 Icon Key Pressure (Pa) Pressure (Pa) 140 120 100 80 150 Speed 1 Speed 2 100 Speed 3 60 50 40 20 0 0 0 20 40 60 0 80 20 Airflow (L/s) Performance - MF150 100 200 60 80 100 Performance - *MF200 300 400 *MF200 Timer model only has 2 speeds, therefore Medium fan speed specifications will not apply. Airflow (m3/hr) Airflow (m3/hr) 0 40 Airflow (L/s) 500 600 700 350 0 200 0 50 400 600 800 1000 300 300 250 250 Pressure (Pa) Pressure (Pa) 200 200 150 100 150 100 50 50 0 0 50 100 Airflow (L/s) 150 200 0 100 150 200 250 300 Airflow (L/s) Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 43 Manrose PRO-SERIES IN-LINE WHISPERVENT FAN Duct Size Model No. Switching Performance Method 150mm Standard 94 l/s, 340m3/hr FAN0916 LB EA R This high efficiency in-line fan is designed to provide higher levels of extraction with low relative noise. The ball bearing motor prolongs the life of the motor. Supported by a 5 year warranty. BAL • • • Whispervent WVI150 Order Code GM OT O R 5 IN YEAR WARRANTY Manrose CLASSIC IN-LINE Hyper FAN • • • • 89 l/s, 320m3/hr FAN0085 This high efficiency in-line fan is designed to provide high levels of extraction. The ball bearing motor prolongs the life of the motor. Includes 1.3m lead and 3 pin plug. Supported by a 5 year warranty. R Standard Hyper150 EA 150mm Order Code LB Switching Performance Method BAL Duct Size Model No. GM OT O R 5 IN YEAR WARRANTY Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery. 44 Technical data Dimension specification Models A B C D WVI150 200 143 170 185 Hyper150 200 143 170 185 TECHNICAL SPECIFICATION Models Whispervent WVI150 Hyper150 Power 220 - 240V 220 - 240V Fan Performance 94 l/s, 340m³/hr 89 l/s, 320m³/hr Fan Wattage 46W 38W Maximum Pressure 160 Pa 135 Pa Fan Speed 2750 RPM 2650 RPM Sound Level 38 dB(A) 46 dB(A) Max. Operating Temp 80°C 70°C IP Rating IPX2 IPX2 Performance - WhisperVent WVI150 36 72 108 144 180 216 Dimensions C A B D Performance - Hyper150 252 70 288 324 360 90 36 72 108 144 180 216 252 70 288 324 360 90 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 45 Manrose CLASSIC IN-LINE AXIAL FANS ID Models Duct Size Model No. Switching Method Performance 3 Order Code 100mm ID100S Standard 23 l/s, 85m /hr FAN0012 100mm ID100T Timer 23 l/s, 85m3/hr FAN0013 125mm ID125S Standard 36 l/s, 130m3/hr FAN0060 3 125mm ID125T Timer 36 l/s, 130m /hr FAN0061 150mm ID150S Standard 87 l/s, 313m3/hr FAN0090 150mm ID150T Timer 87 l/s, 313m3/hr FAN0091 230mm ID230S Standard 152 l/s, 550m3/hr FAN0405 230mm ID230T Timer 152 l/s, 550m3/hr FAN0406 • • • ID100/125/150 With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty. BAL LB EA R ID230 ECO IN-LINE AXIAL FANS OT O R YEAR WARRANTY Duct Size Model No. Switching Method Performance Order Code 150mm ECO150S Standard 64 l/s, 230m3/hr FAN2078 • • • GM 5 IN With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source. High quality sleeve bearing motor. Supported by a 2 year warranty. 2 YEAR WARRANTY Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. 46 NOTE: All fan flow rates quoted are free air delivery. Technical data Dimension specification Models A B C D E ID100 130 155 90 100 27 ID125 150 155 99 118 27 ECO150 (white) 187 153 109 150 27 ID150 187 153 109 150 27 ID230 (square model) 286 286 155 230 - Dimensions - ID Fans C D A E B TECHNICAL SPECIFICATION Models ID100 ID125 ECO150 ID150 ID230 Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V 220 - 240V Fan Performance 23 l/s, 85m³/hr 36 l/s, 130m³/hr 64 l/s, 230m³/hr 87 l/s, 313m³/hr 152 l/s, 550m³/hr Fan Wattage 20W 20W 25W 25W 80W Maximum Pressure 20 Pa 35 Pa 50 Pa 60 Pa 50 Pa Fan Speed 2400 RPM 2000 RPM 2400 RPM 2400 RPM 1250 RPM Sound Level 41 dB(A) 41 dB(A) 40 dB(A) 40 dB(A) 50 dB(A) Max. Operating Temp 50°C 50°C 50°C 50°C 50°C IP Rating IPX4 IPX4 IPX4 IPX4 IPX4 Performance - ID100 Performance - ID125 Performance - ID150 Performance - ID230 Performance - ECO150 Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 47 Manrose CLASSIC IN-LINE CENTRIFUGAL FANS CFD Models Duct Size Model No. Switch Method Performance Order Code 100mm CFD200S Standard 31 l/s, 110m³/hr FAN0326 100mm CFD200T Timer 31 l/s, 110m³/hr FAN0327 125mm CFD225S Standard 39 l/s, 140m³/hr FAN2067 125mm CFD225T Timer 39 l/s, 140m³/hr FAN2066 Manrose Classic In-Line CF 125mm Standard LB EA R These high efficiency centrifugal fans are designed for use where longer duct runs are required. The ball bearing motor prolongs the life of the motor. Supported by a 5 year warranty. BAL • • • GM OT O R 5 IN YEAR WARRANTY Technical data SPECIFICATION DIMENSION INFORMATION (mm) Models CFD200 CFD225 Models A B C D E Power 220 - 240V 220 - 240V CFD200 155 100 100 195 258 Fan Performance 31 l/s, 110m³/hr 39 l/s, 140m³/hr CFD225 155 125 125 195 258 Fan Wattage 20W 20W Maximum Pressure 120Pa 120Pa Fan Speed 1400 RPM 1400 RPM Sound Level 45 dB(A) 45 dB(A) Max. Operating Temp 50°C 50°C IP Rating IPX4 IPX4 Performance - CFD200 Performance - CFD225 Dimensions - CFD200/CFD225 B C A E Switching Options 1. Standard Model - operates from remote switch (not supplied). 3. Requires: permanent phase and switched phase. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. NOTE: All fan flow rates quoted are free air delivery. 48 D SIMX in-line CENTRIFUGAL 3 SPEED FANS High Performance Models Duct Size Model No. Performance @ Speed 3 Order Code 150mm 3 Speed 115 l/s, 415m³/hr FAN0921 200mm 3 Speed 208 l/s, 750m³/hr FAN0997 • Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide high performance at your preset choice of speed. • Supported by a 2 year warranty. Please note: Can be used for supply or extract. 2 TECHNICAL DATA DIMENSION INFORMATION (mm) YEAR WARRANTY Dimensions Models A B C D E 150mm 340 150 154 50 75 200mm 340 200 280 50 50 TECHNICAL SPECIFICATION Models 150mm 200mm Voltage/Freq (50hz) 220 - 240V 220 - 240V Fan Performance Speed 1 65 l/s, 234m³/hr 125 l/s, 450m³/hr Fan Performance Speed 2 90 l/s, 324m³/hr 170 l/s, 620m³/hr Fan Performance Speed 3 124 l/s, 425m³/hr 205 l/s, 740m³/hr Fan Wattage (at high speed) 65W 110W Current (A) (at high speed) 0.36 0.38 Fan Speed (at high speed) 2460 RPM 2700 RPM Sound Level* 43 dB(A) 56 dB(A) Ambient Temp 50°C 60°C * dB(A) - measured 1m free field. Performance - 200mm 3 Speed Performance - 150mm 3 Speed 200mm 3 Speed Centrifugal Fan Curve 400 Pressure (Pa) 300 200 100 100 200 300 400 500 600 700 800 900 1000 Airflow (m3/hr) Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 49 SIMX IN-LINE FANS High Performance Centrifugal Models Duct Size Model No Performance Order Code 100mm MAN100 49 l/s, 176m3/hr FAN0361 125mm 3 61 l/s, 220m /hr MAN125 FAN0360 3 150mm MAN150 115 l/s, 415m /hr FAN0330 200mm MAN200 208 l/s, 750m3/hr FAN0467 250mm 315mm 3 FAN0358 3 FAN0357 280 l/s, 1010m /hr MAN250 360 l/s, 1300m /hr MAN315 • Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide extremely high performance with a choice of sizes. • Supported by a 2 year warranty. Please note: Can be used for supply/extract. Models A B C D E MAN100 250 100 136 50 70 MAN125 250 125 147 60 60 MAN150 340 150 154 50 75 MAN200 340 200 250 50 50 MAN250 320 249 310 65 65 MAN315 405 315 177 80 80 50 2 YEAR WARRANTY DIMENSION INFORMATION (mm) Dimensions Simx 150mm In-Line Fan TECHNICAL DATA Technical INFORMATION Models MAN100 MAN125 MAN150 MAN200 MAN250 MAN315 Voltage/Freq (50hz) 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V Fan Performance 49 l/s, 176m³/hr 61 l/s, 220m³/hr 115 l/s, 415m³/hr 208 l/s, 750m³/hr 280 l/s, 1010m³/hr 360 l/s, 1300m³/hr Fan Wattage 32W 31W 65W 110W 170W 200W Maximum Pressure 153 Pa 143 Pa 320 Pa 418 Pa 500 Pa 590 Pa Current (A) 0.14 0.13 0.35 0.45 0.76 0.87 Fan Speed (min -1) 2500 RPM 2490 RPM 2350 RPM 2520 RPM 2580 RPM 2410 RPM Sound Level* 38 dB(A) 38 dB(A) 50 dB(A) 56 dB(A) 47 dB(A) 57 dB(A) Max Operating Temp 60°C 60°C 50°C 60°C 50°C 45°C * dB(A) - measured 1m free field. Performance - MAN125 Performance - MAN100 Volume (m³/h) 0 20 40 Volume (m³/h) 60 0 80 100 120 140 160 180 100mm 100 150 200 250 0 100 100 80 80 60 60 Static Pressure (Pa) 120 40 20 0 0 10 20 30 125mm 140 120 40 0 10 20 30 Volume (m³/h) 0 450 40 50 60 200 400 400 300 350 250 300 800 0 150 200 250 20 40 Volume (m³/h) 0 200 400 1000 60 80 100 120 600 800 1000 1200 1400 600 315mm 250mm 500 400 300 200 Static Pressure (Pa) Static Pressure (Pa) Volume l/s 50 0 250 200 100 150mm Performance - MAN315 600 450 200mm 350 50 400 100 70 500 0 350 Volume l/s 0 100 200 300 400 500 600 700 800 900 0 300 0 Volume (m³/h) 50 250 150 Performance - MAN250 100 200 200 20 50 150 150 250 Volume l/s 400 100 300 40 Volume l/s Performance - MAN200 50 350 Static Pressure (Pa) 140 Static Pressure (Pa) Volume (m³/h) 50 160 160 Static Pressure (Pa) Performance - MAN150 150 100 50 0 0 50 Volume l/s 100 150 200 250 300 200 100 0 0 50 100 150 200 250 300 350 400 Volume l/s Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 51 SIMX IN-LINE CENTRIFUGAL FANS WhisperVent Low Profile Models Duct Size Model No Performance Order Code 150mm WVILP150-1 124 l/s, 445m3/hr FAN0829 150mm WVILP150-3 118 l/s, 425m3/hr FAN0830 • • Suitable for a variety of domestic and commercial applications, this in-line centrifugal fan offers high performance with a low profile design to enable this unit to be installed in confined spaces. Supported by a 2 year warranty. 2 DIMENSION INFORMATION (mm) YEAR WARRANTY Models A B C D E WhisperVent Low Profile 313 168 148 340 218 Dimensions A D E B 52 ØC TECHNICAL DATA Technical specification Models Fan Speed FAN0830 1 65 l/s, 234m³/hr FAN0830 2 FAN0830 FAN0829 Fan Performance Norm Fan Speed (RPM) Single Phase Nom Watts Nom Amps 1440 50 0.22 90 l/s, 324m³/hr 1860 56 0.24 3 124 l/s, 445m³/hr 2460 80 0.36 1 118 l/s, 425m³/hr 2520 80 0.36 SOUND POWER LEVEL Model No Sound Power Levels Lw (A) Octave band centre frequency in Hz dB(A) @ 3m 63 125 250 500 1k 2k 4k 8k FAN0830 - Speed 1 - 20 34 43 43 44 40 30 30 FAN0830 - Speed 2 - 26 40 51 51 52 45 38 36 FAN0830 - Speed 3 - 40 42 62 64 64 59 45 43 57 61 68 67 65 64 59 53 43 FAN0829 Performance - FAN0829 & FAN0830 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 53 SIMX EXTERNAL WALL MOUNTED Fans Extract MODELS Duct Size Fan Type Air Performance Order Code 150mm Axial Extract* 73 l/s, 263m3/hr FAN2303 150mm Ctr’fgl (190 Motor) Extract 109 l/s, 392m3/hr FAN2425 150mm Ctr’fgl (220 Motor) Extract 133 l/s, 480m3/hr FAN2424 *Also available in a Supply Air option • • • Designed for use in residential and light commercial applications where a high performance, low noise solution is required. Specific applications include apartments where space is limited. Supported by a 2 year warranty. 150mm Ctr’fgl (190 Motor) SIMX EXTERNAL WALL Mounted Fans 3 Speed Extract MODELS Duct Size Fan Type Air Performance (High Speed) Order Code 150mm Ctr’fgl (190 Motor) Extract 113 l/s, 408m3/hr FAN2423 150mm Ctr’fgl (220 Motor) Extract 136 l/s, 493m3/hr FAN2426 • • • • Designed for use in residential and light commercial applications where a high performance, low noise solution is required. Three speed models enable further flexibility in a variety of applications. Specific applications include apartments where space is limited. Supported by a 2 year warranty. Wall mounted with measurements 369mm 369mm 305mm 110mm 110mm 305mm Switching Options 1. Electrical connection must be made internally (Junction Box is only suitable for internal use). NOTE: All fan flow rates quoted are free air delivery. 54 Fan Assembly - Line Drawing 2 YEAR WARRANTY TECHNICAL DATA PERFORMANCE DATA Order Code Motor Size Description (mm) FAN2303 150 FAN2425 Fan Performance m³/hr l/s Watts @ 230V Axial 263 73 48 0.29 80 48 150 Centrifugal 190 Motor (1 Speed) 392 109 65 0.28 280 60 FAN2424 150 Centrifugal 220 Motor (1 Speed) 480 133 96 0.42 380 61 FAN2423 150 Centrifugal 190 Motor (3 Speed) High Speed 408 113 65 0.28 280 60 Medium Speed 340 94 57 0.25 250 56 Low Speed 277 77 55 0.24 200 46 High Speed 493 136 96 0.42 380 61 Medium Speed 408 113 69 0.34 340 56 Low Speed 340 94 60 0.31 280 50 FAN2426 Amps Static Sound Level Pressure (Pa) (dB(A) @ 3m) Centrifugal 220 Motor (3 Speed) 150 400 350 Icon Key 300 Pressure (Pa) 250 200 FAN2303 150mm AXIAL 150 FAN2425 150mm CENTRIFUGAL (190 Motor) 100 50 FAN2424 150mm CENTRIFUGAL (220 Motor) 0 0 50 100 150 Airflow (L/s) 400 350 300 Pressure (Pa) 250 200 150 FAN2423 150mm 3 SPEED CENTRIFUGAL (190 Motor) 100 50 FAN2426 150mm 3 SPEED CENTRIFUGAL (220 Motor) 0 0 50 100 150 Airflow (L/s) Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 55 THRU-ROOF MOUNTED FANS Thru Roof Fan Cowl Models Duct Size 150mm 150mm 150mm Fan Type Ctr’fgl Ctr’fgl 3-spd Axial - Whisper Air Extract Extract Extract Performance Order Code 3 FAN0529 3 FAN1002 153 l/s, 550m hr 153 l/s, 550m hr 3 FAN1009 3 89 l/s, 320m /hr 150mm Axial Extract 75 l/s, 270m /hr FAN0531 150mm Axial - Whisper Supply 75 l/s, 270m3/hr FAN0533 150mm Axial - Whisper • High quality aluminium cowl construction, with fan incorporated, for longevity of operation. • Supported by a 2 year warranty. With Flashing & HDPE Tube Duct Size Fan Type Air Performance Order Code 150mm Ctr’fgl Extract 153 l/s, 550m3hr FAN0530 3 150mm Ctr’fgl 3-spd Extract 153 l/s, 550m hr FAN0967 150mm Axial - Whisper Extract 89 l/s, 320m3/hr FAN1060 3 150mm Axial Extract 75 l/s, 270m /hr FAN0532 150mm Axial Supply 75 l/s, 270m3/hr FAN0534 150mm 150mm H/D Axial H/D Ctr’fgl Extract Extract 3 75 l/s, 270m /hr 3 153 l/s, 550m hr FAN0739 FAN0740 150mm Axial - Whisper 2 YEAR WARRANTY H/D = Heavy Duty cowl used in these kits. • • • High quality aluminium cowl construction, with fan incorporated for longevity of operation. Includes Flashing for metal based roofs, an optional lead Flashing is available for concrete tile roofs (DCT0190) at an additional cost. Supported by a 2 year warranty. Thru Roof Fan System Models Duct Size Description Fan Type Performance* Order Code 150mm Ultra Ctr’fgl 153 l/s, 550m3/hr FAN0535 150mm • • • Hyper Hyper 3 75 l/s, 270m /hr DCT0189 High quality aluminium cowl construction, with fan incorporated, for longevity of operation. Includes Flashing for metal based roofs, an optional lead Flashing is available for concrete tile roofs (DCT0190) at an additional cost. Supported by a 2 year warranty. 150mm Hyper Fan System Connection 1. Electrical connection can be made inside or outside the roof space. * NOTE: All fan flow rates quoted are motor performance in free air. 2 YEAR WARRANTY 56 TECHNICAL DATA Dimension information (mm) Dimensions - Thru Roof Fans Models A B C FAN0529 - FAN1002 275 170 - FAN1009 275 170 - FAN0531- FAN0533 275 170 - FAN0530 - FAN0967 275 170 500 FAN1060 275 170 500 FAN0532 - FAN0534 275 170 500 FAN0739 - FAN0740 275 170 500 A B C TECHNICAL SPECIFICATION Models FAN0529 FAN0530 FAN0740 FAN1002 FAN0967 FAN0531 FAN0532 FAN0739 FAN0533 FAN0534 FAN1009 FAN1060 Supply Voltage 220-240VAC 220-240VAC 220-240VAC 220-240VAC 220-240VAC Fan Centrifugal Axial Axial Axial - Whisper Centrifugal 3 3 Fan Performance 153 l/s, 550m /hr 153 l/s, 550m /hr 75 l/s, 270m /hr 75 l/s, 270m /hr 89 l/s, 320m3/hr Fan Wattage 58W 58W 44W 44W 46W Maximum Pressure 320 Pa 320 Pa 80 Pa 130 Pa 130 Pa Fan Speed 2500 RPM 2500 RPM 2850 RPM 2850 RPM 2750 RPM Sound Level @ 1m 62 dB(A) 62 dB(A) 55 dB(A) 55 dB(A) 38 dB(A) Operating Temp -25 - +50°C -25 - +50°C -20 - +80°C -20 - +80°C -20 - +80°C IP Rating IPX4 IPX4 IPX2 IPX2 IPX2 Performance - FAN0529/FAN0530/FAN0740 3 3 Performance - FAN0531/FAN0532/FAN0739 90 350 80 300 70 60 Pressure (Pa) Pressure (Pa) 250 200 150 50 40 30 100 20 50 10 0 0 50 100 150 0 200 0 20 40 Airflow (L/s) FAN0530 / FAN0555- FAN0533/FAN0534 Performance 80 100 120 Performance - FAN1009/FAN1060 FAN0532 / FAN0553 90 160 80 140 70 120 Pressure (Pa) 60 Pressure (Pa) 60 Airflow (L/s) 50 40 30 100 80 60 40 20 20 10 0 0 20 40 60 80 100 120 0 0 Airflow (L/s) FAN0532 / FAN0553 50 100 150 Airflow (L/s) FAN1009 / FAN1060 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 57 Manrose PRO-SERIES HAND DRYERS PUBLIC AREAS/HEAVY USAGE APPLICATIONS NEW Designed to provide a cost effective alternative to conventional Hand Dryers. Providing a rapid drying time of 10 seconds, almost half that of the competitors products, thus reducing washroom time. Switching Performance Method Model No. Cover MAN/E-88AE Stainless White Steel Auto 56 l/s, 200m3/hr FAN2287 MAN/E-88AEBC Stainless Satin Steel Auto 56 l/s, 200m3/hr FAN2286 • • • • Colour Order Code Heavy Usage Hand Dryers 70% energy savings. Tamper Proof Technology. Suitable for use in public areas for heavy usage. Supported by a 5 year warranty. Manrose Hand Dryer - MAN/E-88AE Manrose CLASSIC HAND DRYERS PUBLIC AREAS/HEAVY USAGE APPLICATIONS Model No. Cover Colour Switching Performance Method MAN/M-88A ABS Thermoplastic White Auto 56 l/s, 200m3/hr FAN2902 MAN/A-89 3mm Aluminium White Auto 108 l/s, 388m3/hr FAN4396 MAN/A-89S 3mm Aluminium Silver Auto 108 l/s, 388m3/hr FAN4395 MAN/A-89B 3mm Aluminium Black Auto 108 l/s, 388m3/hr FAN4397 MAN/E-88A Porcelain Enamel 2mm Steel White Auto 130 l/s, 470m3/hr FAN2903 • • Order Code These models are suitable for use in public areas such as lavatories, factories, schools, railways and motorway service stations and are designed for heavy usage and unsupervised areas. Supported by a 2 year warranty. Manrose Hand Dryer - MAN/E-88AEBC Manrose MAN/M-88A Manrose MAN/A-89 Colour Options available: White, Silver and Black Manrose MAN/E-88A 2 YEAR WARRANTY 58 TECHNICAL DATA Dimension information Dimension SPECIFICATION (mm) - Hand dryers Model A B C MAN/E-88AE 201 277 175 MAN/E-88AEBC 201 277 175 MAN/M-88A 225 275 160 MAN/A-89 225 275 160 MAN/E-88A 284 248 202 TECHNICAL SPECIFICATION - Pro-Series Dimensions - MAN/E-88AE Models, MAN/E-88AEBC Models MAN/E-88AE MAN/E-88AEBC Power 220 - 240V 220 - 240V Cover Stainless Steel Stainless Steel Colour White Stainless Satin Steel 3 Fan Performance 56 l/s, 200m /hr 56 l/s, 200m3/hr Operation No touch infra-red detection No touch infra-red detection Heater Element 450 - 900W adjustable 450 - 900W adjustable Power 1.6kW @ 240V 1.6kW @ 240V Dry Time 10 secs 10 secs Sound Level 74 dB(A) 74 dB(A) Weight 7.0kg 7.0kg A B C Dimensions - MAN/M-88A, A-89, A-89S A-89B A TECHNICAL SPECIFICATION - CLASSIC B Models MAN/M-88A MAN/A-89 MAN/E-88A Power 220 - 240V 220 - 240V 220 - 240V C Depth Cover Colour ABS Thermoplastic 3mm Aluminium White Fan Performance 56 l/s, 200m³/hr Steel 2mm Porcelain Enamel White, Silver, Black White 108 l/s, 388m3/hr 130 l/s, 470m³/hr Operation No touch infra-red detection No touch infra-red detection No touch infra-red detection Power 1.5kW @ 240V 2.0kW @ 240V 2.4kW @ 240V Sound Level 54 dB(A) 69 dB(A) 70 dB(A) Weight 3.3kg 4.7kg 7.5kg Dimensions - MAN/E-88A A Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au B Depth C 59 SPECIALISED FANS Frame Fan Model Duct Size Model No. Switching Method Performance 120mm Frame Fan Standard 38 l/s, 138m³/hr FAN0397 150mm Frame Fan Standard 89 l/s, 320m³/hr FAN1043 • • • Order Code This frame fan is designed for use in computer rooms or applications where the introduction of cool air is required for small enclosed spaces. The ball bearing motor prolongs the life of the motor. Supported by a 2 year warranty. Frame Fan 125mm ACCESSORIES Duct Size Description Order Code 120mm Finger Guard for FAN0397 - Metal FAN0412 120mm Filter Guard for FAN0397 FAN0413 150mm Finger Guard for FAN1043 FAN0841 TECHNICAL DATA 2 Technical information YEAR WARRANTY Models Frame Fan 125 Frame Fan 150 Power 220 - 240V 220 - 240V Fan Performance 38 l/s, 138m³/hr 89 l/s, 320m³/hr Fan Wattage 15W 38W Models A B C Maximum Pressure 62Pa 135Pa Frame Fan 125 120 120 105 40 Fan Speed 2650 RPM 2650 RPM Frame Fan 150 172 150 160 51 Sound Level 43 dB(A) 46 dB(A) Max. Operating Temp 80°C 70°C IP Rating IPX4 IPX2 Performance - 125mm Frame Fan Dimension SPECIFICATION Performance - 150mm Frame Fan Dimensions - Frame Fan D 36 72 108 144 180 216 252 288 D 324 360 A C B 70 NOTE: All fan flow rates quoted are free air delivery. 60 90 Manrose CLASSIC DC SPECIALISED FANS 12/24V Extract-a-lite Models Duct Size Model No. Switching Colour Method Performance Order Code 100mm BSL112W Standard 18 l/s, 64m3/hr FAN0625 White 3 100mm BSL112G Standard Gold 18 l/s, 64m /hr FAN0690 100mm BSL112C Standard Chrome 18 l/s, 64m3/hr FAN0691 3 100mm BSL124W Standard White 18 l/s, 64m /hr FAN0626 100mm BSL124G Standard Gold 18 l/s, 64m3/hr FAN0686 100mm • • • • BSL124C Standard 3 Chrome 18 l/s, 64m /hr FAN0685 A compact extractor fan combined with an integral halogen light. Designed for installation in galleys, showers and toilets, ideal for marine and other leisure applications. Long life computer motor which will run continuously, only 2.8 watts. Supported by a 2 year warranty. Dimensions - DC Extract-a-lite ACCESSORIES - Extract-a-lite Cowl C Duct Size Description Order Code 100mm Extract-a-lite cowl DCT1097 E B A • External cowl suitable for use in marine and non-marine applications TECHNICAL DATA F D Dimension information Models A B C D E F BSL112 140 90 52 12 98 38 BSL124 140 90 52 10 98 38 A TECHNICAL SPECIFICATION Performance - DC Extract-a-lite Models BSL112 BSL124 Power 12 VDC 24 VDC Fan Performance 18 l/s, 64m³/hr 18 l/s, 64m³/hr Fan Wattage 45W 45W Maximum Pressure 125 Pa 125 Pa Fan Speed 1400 RPM 1400 RPM Sound Level 45 dB(A) 45 dB(A) Max. Operating Temp 40°C 40°C IP Rating IPX4 IPX4 2 YEAR WARRANTY Switching options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery. 61 FAN ACCESSORIES Fan timer Model No. Description Order Code Time Air 7 Minute Fixed Timer (suits fans 20W-200W) FAN0372 • A fixed fan timer that will automatically switch the appliance off after approximately 7 minutes. Description Order Code Fully Adjustable Run-On Fan Timer FAN2444 Time Air - Fan Timer • Timing Switch 1 Sec to 90 Mins. • Adjustable Run Timer & Start Delay. Transformers Fully adjustable Run-On Fan Timer Model No. Description Order Code ACTO TE0060 Electronic Transformer 12VAC 50kHz FAN2101 • • • • • This transformer must only be used with 12V lighting installations. Supports lamp wattages from 20W - 60W. Overload & short circuit protection with self resetting. Over temperature cut off. Dimmable with trailing and leading edge dimmers. Model No. Description Order Code TM 50-2-07 SELV Isolating Transformer 12VAC FAN2402 • • • • • • • • Electronic Transformer SELV isolating transformer is required for all low voltage fan installations. Can be used with low voltage 12V lighting. Supports lamp wattages from 20W - 50W. An iron core transformer. Thermally stable and shatter-proof plastic casings. Overload & short circuit protection with self resetting. Over temperature cut off. Dimmable with trailing and leading edge dimmers. Humidistat Controller Model No. Description Order Code 1360 Humidistat Controller FAN0963 • • • 62 Designed to operate the fan when the relative humidity (RH) reaches a preset level. Fits a double pattress. This unit is adjustable between 20 - 90% RH. Humidistat Controller FAN ACCESSORIES ULTECON Thermostats Model No. Description Order Code TA01 Analogue Thermostat FAN0153 TD01 Digital Thermostat FAN0981 TD02 Digital 2 Speed Thermostat FAN0982 TD03 Digital 3 Speed Thermostat FAN0983 • • • • High quality, easy to use thermostats. Dual output switching for both cooling and heating situations. Electronic temperature sensor. Included in Heat Trans systems. TD03 Digital 3 Speed Thermostat Speed Controllers Model No. Description Switching Method Order Code 1348 For XF/XP/WF 230/300 Fans* 2 Spd + Reverse FAN0155 1349 For XF/XP/WF 230/300 Fans* Adjust + Reverse FAN0156 1350 For any XF/XP/WF 230/300 Fans Adjustable FAN0157 PDL625F General Purpose up to 500W On-Off + Adjust FAN2104 • A range of speed controllers with variable or 2 speed and reversible options. • Models 1348-1350: Electrical load must be between 20 and 200 watts. • FAN0154 - Single pattress mounting block for FAN0155/0156/0157. PDL625F General Purpose *Not suitable for manual pull cord model fans. ULTECON Speed Controller Model No. Description Input Output Current Power Order Code SPC05 Ultecon 5 Speed Fan Controller 1A FAN1096 100W • 5 speed fan selection - manual or external control. • Enclosure can be wall mounted or free standing. • On/Off switch. Ulecon 5 Speed Fan Controller Fan Mounting Brackets Duct Size Description Order Code 100-200mm Fan Mounting Bracket for 100 - 200mm FAN0015 250-315mm Fan Mounting Bracket for 250 - 315mm FAN0016 • These adjustable fan mounting brackets, designed for use with the centrifugal fans. • Supplied in pairs. 100-200mm Fan Mounting Bracket Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 63 AUSTRALIAN DUCT STANDARDS system then YOU ARE IN BREACH OF AS 4254, not the manufacturer/duct assemblers. We strive to provide the best possible flexible duct at a competitive and fair price, that complies to all necessary Standards. Ducting that does not comply to AS 4254 may be used on Reverse Cycle and Evaporative Systems except in Victoria. The onus is on you to choose and use compliant product. Australian Standards (AS) 4254 & (AS) 4508 Most Commonly Asked Questions: Q. What is AS 4254? Q. What is AS 4508? A. Australian Duct Fire Standard (AS) 4254. This standard was developed to ensure public safety, that the product tested will not support combustion and will function as designed for its service life. All heating systems in Australia ignited from a flame source and all commercial class 2 to 9 buildings must FULLY COMPLY with AS 4254. In Victoria all Ducting Installations must be fire rated to AS 4254. Q. How do I know if the duct passes AS 4254? A. If a flexible duct passes AS 4254 it has been tested to and passed eleven difficult tests. Ensure the product in the test has been tested in its composite form, just the way you buy it, i.e. duct core, insulation blanket and outer jacket. Each test should state product name and its componentry make-up. If you cannot be supplied test reports to cover each of the eleven tests or there is a reluctance from duct manufacturers/duct assemblers to produce any or all of these reports it is likely that the duct DOES NOT comply to AS 4254. Manufacturers/duct assemblers are under no obligation to produce AS 4254 compliant product. If you install flexible duct that does not comply, on a gas fired heating A. Australian insulation Standard (AS) 4508. Due to poor quality insulation being used on ducting, AS 4508 was developed to create minimum acceptable thermal values for ducting, helping to reduce the greenhouse effect and lower running costs. This standard specifies how insulation on the ducting must be tested so an overall thermal or “R” value can be achieved consistently throughout all the duct in the system. Q. How do I know if the insulation meets the requirements of AS 4508? A. Ask to see the test report from your duct manufacturer /duct assembler that shows that the insulation had been tested to and complies with AS 4508. To achieve a thermal rating of R0.6 you must use a minimum of 250 g/ m² polyfibre insulation at 40mm thick. To achieve an R1.0 you must use a minimum of 450 gram/square metre polyfibre insulation at 70mm thick. Fibreglass thermal values remain the same as they have for years, 25mm=R0.6 and 40mm=R1.0. There will be variations depending on the manufacturer of the insulation but in general the above rules apply. Compliance to AS/NZ 1530 Part 3 AS/NZS 1530 Part 3 Requirements are: This is the Australian standard 1530, method for fire tests on building materials components and structures. Internal Surface: Spread of flame not >0 Smoke Developed not >3 External Surface: Spread of flame not >7 Smoke developed not >5 “Simultaneous determination of ignitability, flame propagation, heat release and smoke release” AS 4254 comprises of the tests listed below: (AS) 1530 part 3 - radiant burn test Underwriters Laboratories 64 (U.L) 181 part 9 - flaming burn test (U.L) 181 part 14 - static load test (U.L) 181 part 11 - mould growth test (U.L) 181 part 15 - impact test (U.L) 181 part 12.2 - low temperature test (U.L) 181 part 17 - positive & negative pressure test (U.L) 181 part 12.3 - high temperature test (U.L) 181 part 18 - collapse test (U.L) 181 part 13 - puncture test (U.L) 181 part 19 - tension test DUCTING INSTALLATION & USAGE The layout of flexible duct, the number of bends, the sharpness of the bend and the amount of sag allowed between support joints will have serious effects on system performance due to the increased resistance to airflow each introduces. Use the minimum length of flexible duct to make connections. It is not recommended that excess length of ducts be installed to allow for possible future relocations of air terminal devices. Avoid installation where exposure to direct sunlight can occur e.g: skylight. Grilles and diffusers need to be supported independently of the flexible duct. Repair torn or damaged vapour barrier/jacket with duct tape listed and labelled to Standard AS4254. If internal core is penetrated, replace flexible duct or treat as a join. Right Setup Install duct fully extended, do not install in the compressed state or use excess lengths. This will noticeably increase friction losses. Wrong Setup Avoid bending ducts across sharp corners or incidental contact with metal fixtures, pipes or conduits. Flexible ducts shall be installed with a bend radius to duct diameter ratio in accordance with the following info on the next page. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 65 DUCTING INSTALLATION & USAGE Duct velocity R/D ratio centerline radius to duct diameter: Up to 5m/s x 0.6 5m/s x 1.0 Above 8m/s x 1.5 e.g. Assuming duct velocity of 8m/s Steam Pipes Wrong Setup Do not install near hot equipment (e.g. heaters boilers, steam pipes etc.) that is above the recommended flexible duct use temperature. 66 AIR DUCTS 01 Non-metallic with Plain Ends. After desired length is determined, cut completely around and through duct with knife or scissors. Cut wire with wire cutters. Fold back duct jacket and insulation. 02 Slide at least 1” (25mm) of core over the fitting up to the bead. Seal the core to collar with at least two wraps of duct tape. Secure connection with cable ties placed over the core and duct tape. 03 Pull jacket and insulation back over core. Tape jacket with at least 2 wraps of duct tape ensuring end of the outer jacket is secured to the spigot. Cable ties may be used in place of or in combination with the duct tape. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 67 JOINS 01 Fold back duct jacket and insulation from core. Butt two cores together on a 4” (100mm) length metal sleeve or polymer sleeve. 02 03 Tape cores together with at least 2 wraps of duct tape. Connection can be secured with 2 cable ties placed over the taped core ends. Pull jacket and insulation back over cores. Tape jackets together with at least 2 wraps of duct tape. 68 SUPPORTING FLEXIBLE DUCT 01 Flexible duct shall be supported at intervals, no greater distance than 1.5m. Maximum permissible sag is 60mm per metre of spacing between supports. A connection to rigid duct or equipment shall be considered a support joint. SAG 60mm Long horizontal duct runs with sharp bends shall have additional supports before and after the bend approximately one duct diameter from the centreline of the bend. Recommend Hanging Straps DCT0808. 02 Hanger or saddle material in contact with the flexible duct shall be of sufficient width to prevent any restriction of the internal diameter of the duct when the weight of the supported section rests on the hanger or saddle material. In no case will the material contacting the flexible duct be less than 40mm wide. 40mm min 40mm Wire 03 Factory installed suspension systems integral to the flexible duct is an acceptable hanging method. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 69 SUPPORTING FLEXIBLE DUCT Flexible ducts may rest on ceiling joists or truss supports. Maximum spacing between supports shall not exceed 1.5m. Ceiling Joist (1.8m) Max Vertically installed duct shall be stabilised by support straps at a max of 1.8m. Support the duct between a metal connection and bend by allowing the duct to extend straight for 100mm before making the bend. This will avoid possible damage of the flexible duct by the edge of the metal collar. NOTE: Upon completion of installation, please test in accordance with 2.8.2 of standard AS4254. NOTE: factory-made air ducts may not be used for vertical risers in air duct systems serving more than two stories. 70 FLEXIBLE DUCTING Flexible Ducting Friction FRICTION LOSS GRAPH Loss Graph Technical Data Flexible Ducting Friction Loss Graph Technical Data 3/h 3/h Air Volume mm AirVolume Air Volume m3/h (m3/h 3.6 = l/s) 3/h / 3.6 = l/s) 3/h (m(m / 3.6 = l/s) (m3/h / 3.6 = l/s) Air Volume m3/h Diameter of Duct in mm Flexible Ducting Friction Loss Graph Friction Loss (Pa per metre) 40 40 metre) Loss (Pa Friction FrictionLoss (Paperper metre) 0 Technical Data Friction Loss (Paper metre) Fax: (09) 259 1661 • Email: sales@securimax.co.nz • Website: www.securimax.co.nz Fax: (09) 259 1661 • Email: sales@securimax.co.nz • Website: www.securimax.co.nz Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au Fax: (09) 259 1661 • Email: sales@securimax.co.nz • Website: www.securimax.co.nz 71 ALUDUCT/COMFLEX FLEXIBLE DUCTING Diameter (mm) Length (m) MANROSE ALUDUCT COMFLEX NUDE COMFLEX INSULATED Order Code Order Code Order Code 100 1 3 6 DCT0357 DCT0328 125 1 3 6 DCT0358 DCT0329 150 1 3 6 DCT0359 DCT0330 200 3 6 250 3 6 DCT0367 DCT0409 Nude DCT0368 DCT0410 DCT0369 DCT0411 DCT0088 DCT0399 DCT0331 DCT0377 DCT0412 DCT0089 DCT0343 DCT0332 DCT0370 DCT0413 DCT0400 DCT0344 300 3 6 DCT0380 DCT0414 DCT0401 DCT0402 350 3 6 DCT0415 DCT0416 DCT0403 DCT0404 400 3 6 DCT0417 DCT0418 DCT0405 DCT0406 • • • • • • Insulated Fully complies to AS 1530 Pt3. DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto a corrosion resistant coated, spring steel wire helix. DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised. DUCT INSULATION: AS4508 Polyester R0.6. TEMPERATURE RANGE: Maximum: +80ËšC, Minimum: -10ËšC. COLOUR: Silver with black sleeve. Colour Code Label Guide: Ducting Black 150mm (6”) Blue 250mm (10”) Red 350mm (14”) Yellow 200mm (8”) White 300mm (12”) Grey 400mm (16”) Note All 1 metre lengths are packed in bags with header cards, 3 metre aluduct duct is supplied boxed and all other items are supplied in colour coded bags. No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure. Products with the “order code” shown are generally ex. stock lines - other products are available to order. 72 Should you have an ongoing requirement for an item that is not a standard stock line - PLEASE discuss with us and we will review stocking the item for you. UNILOK FR1 Acoustic Ducting INSULATED R0.6 INSULATED R1.0 Order Code Order Code Diameter (mm) Length (m) 100 3 6 DCT1216 DCT1268 125 3 6 DCT1164 DCT1224 DCT1176 150 3 6 DCT0633 DCT0634 DCT0833 DCT0834 200 3 6 DCT0635 DCT0636 DCT0835 DCT0836 Acoustic Insulated R0.6 (40mm) UNILOK FR1 Acoustic Ducting is a flexible duct manufactured “tough” & “whisper quiet” for consumer & installer peace of mind. Unlike other types of flexible duct, UNILOK FR1 has an outer steel rib that ensures the products integrity, and correct diameter, even in the tightest bends. Due to its steel rib, it is not prone to glue failure or fatigue (sagging or ovalisation) from vibration with age like plastic ribbed or non-ribbed glued duct. • • • • • • • • Fully complies to AS1530 Pt3. Designed for low noise air transfer. Fully flexible same mechanical construction as standard Unilok ducting. DUCT CORE: A UV resilient fire retardant 100μm black low density polyethylene perforated material mechanically locked into an outer metal helix with a copper coated spring steel wire. DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised. DUCT INSULATION R0.6: AS4508 Polyester R0.6. DUCT INSULATION R1.0: AS4508 Polyester R1.0. TEMPERATURE RANGE: Maximum: +80ËšC, Minimum: -10ËšC. Insertion Loss, dB Octive Band Centre Frequency Sample 125 250 500 1000 2000 4000 8000 150mm UNILOK FR1 R0.6 AI 35.5 39.2 36.0 30.3 29.8 31.5 22.5 300mm UNILOK FR1 R0.6 AI 33.3 35.9 27.3 31.0 28.1 17.0 12.2 400mm UNILOK FR1 R0.6 AI 36.1 30.0 20.6 27.2 26.0 12.7 10.5 Colour Code Label Guide: Ducting Black 150mm (6”) Yellow 200mm (8”) Note 1. Products with the “order code” shown are generally ex. stock lines - other products are available to order 2. Should you have an ongoing requirement for an item that is not a standard stock line – PLEASE discuss with us and we will review stocking the item for you. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 73 Manrose PVC Flexible Ducting Diameter (mm) Length (m) Pack Order Code 100 1 3 Header Carded Boxed DCT0936 DCT0336 125 1 4 Header Carded Boxed DCT0937 DCT0337 150 1 5 Header Carded Boxed DCT0938 DCT0338 150mm PVC Flexible Ducting P.V.C Flexible Duct is a product that is extremely versatile in the ventilation industry. It doesn’t rot, is non-collapsing, is fire resistant, has an operating temperature of +6° to +50° and is available in a range of sizes from 100mm to 150mm. • • • • • • • Fully complies to AS1530 Building code. DUCT CORE: Spiral wire reinforced PVC film construction. Non-collapsing/non-rotting. Vapour-proof. Fire retardant. TEMPERATURE RANGE: Maximum: +50ËšC : Minimum: 6ËšC. COLOUR: White PVC. SEMIDUCT Semi Rigid Ducting Diameter (mm) Length (m) Pack Order Code 100 1.5 3 Boxed Loose DCT0333 DCT0114 125 1.5 3 Boxed Loose DCT0334 DCT0115 150 1.5 3 Boxed Loose DCT0335 DCT0116 200 3 Loose DCT0117 250 3 Loose DCT0118 300 3 Loose DCT0119 350 3 Loose DCT0120 400 3 Loose DCT0477 Semiduct Semi Rigid Ducting SEMIDUCT is also known as semi-rigid aluminium ducting is a lightweight, flexible but strong corrugated aluminium duct. It is spiral wound with a unique interlocked and knotted continuous seam. It is self supporting over longer lengths and generally only needs fittings or mechanics at each end for support. • • • • • 74 Fully complies to the Building Code of Australia. DUCT CORE: Pure aluminium spiral wound with a unique interlocked and knurled continuous seam. Holds shape, self supporting. TEMPERATURE RANGE: Maximum: +250°C, Minimum: -30°C. COLOUR: Silver. Manrose SOLID TUBE Solid Tube - Rigid Steel Diameter Length (mm) (m) Finish Order Code 100 0.9 Galvanised DCT0151 100 0.9 White DCT0145 125 0.9 Galvanised DCT0152 125 0.9 White DCT0146 125 1.2 Galvanised DCT0953 150 0.9 Galvanised DCT0153 150 0.9 White DCT0147 150 1.2 Galvanised DCT0954 Acoustic Insulated R0.6 (40mm) Solid Tube - White Plastic Diameter (mm) Length (m) Finish Order Code 100 0.9 PVC DCT1424 125 0.9 PVC DCT1425 150 0.9 PVC DCT1426 Manrose Low Profile Ducting Flat Channel Dimension (mm) Equivalent Size (mm) Length (m) Order Code 110 x 54 100 1.5 DCT0013 204 x 60 125 1.5 DCT0519 220 x 90 150 1.5 DCT1443 300 x 25 100 1.5 DCT1460 Low profile ducting enables it to be concealed when installed along the top of wall units. It can also be fitted in ceiling voids and cavity walls, providing versatility whilst remaining unobtrusive. All Manrose system parts and channels are made from flame-retardant material. Four Low Profile System Sizes 110mm x 54mm: Suitable for applications requiring low extraction rates, such as ventilation of domestic bathrooms and toilets. With a 5940mm2 cross-section it provides efficient ducting for short, straight runs connecting to a 100mm round spigot. 204 x 60 Low Profile Ducting Flat channel 204mm x 60mm: Suitable for ducting of kitchen cooker hoods with 100, 125 or 150mm round exhaust spigots. The flat channel cross section of 12240mm2 increases efficiency. High Performance 220mm x 90mm: Suitable for applications requiring high performance extraction or supply. The flat channel cross section of 19800mm2 makes it highly efficient and higher extraction rates are achieved. Flat Ducting 300mm x 25mm: Suitable for applications where space is very limited. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 75 Manrose LOW PROFILE DUCT FITTINGS Low Profile Connectors Horizontal 90° Bends Vertical 90° Bends Dimension (mm) Order Code Dimension (mm) Order Code Dimension (mm) Order Code 110 x 54 DCT0014 110 x 54 DCT0125 110 x 54 DCT0126 204 x 60 DCT0520 204 x 60 DCT0524 204 x 60 DCT0525 220 x 90 DCT1442 220 x 90 DCT1448 220 x 90 DCT1447 300 x 25 DCT1459 300 x 25 DCT2097 300 x 25 DCT2099 Horizontal 45° Bend Vertical 45° Bend Dimension (mm) Order Code Dimension (mm) Order Code 300 x 25 DCT2098 300 x 25 DCT1455 Short Adapter Rectangular: Round Adapters Rectangular: Round Horizontal T-Piece Connectors Dimension (mm) Order Code 110 x 54 DCT1479 204 x 60 DCT1114 Flat Channel Reducers Dimension (mm) Order Code Dimension (mm) Order Code Dimension (mm) Order Code 110 x 54 : 100 DCT0127 (f) 110 x 54 : 100 DCT1482 110 x 54:204 x 60 DCT0136 110 x 54 : 100 DCT0131 (m) 204 x 60 : 125 DCT0526 204 x 60:220 x 90 DCT1452 220 x 90 : 150 DCT1446 300 x 25:204 x 60 DCT1456 300 x 25 : 100 DCT1461 (m) = Male (f) = Female 76 Designed to fit 204 x 60mm flat channel or airbrick. Elbow Bends 100mm Elbow Bends 125mm Elbow Bends 150mm Dimension (mm) Order Code Dimension (mm) Order Code Dimension (mm) Order Code 110 x 54 DCT0124 (m) 204 x 60 DCT0522 204 x 60 DCT0523 110 x 54 DCT0015 (f) 220 x 90 DCT1440* 220 x 90 DCT1441* 204 x 60 DCT0521 300 x 25 DCT2096 220 x 90 DCT1444 300 x 25 DCT2095 *Rotating offset spigot *Rotating offset spigot (m) = Male (f) = Female Horizontal Bend Adjustable Horizontal Airbrick Insert Vertical Airbrick Insert Dimension (mm) Order Code Dimension (mm) Order Code Dimension (mm) Order Code 204 x 60 DCT1480 204 x 60 DCT0137 204 x 60 DCT1414 Double Airbrick Dimension (mm) Order Code 232 x 138 DCT1450 Duct connection requires the following Reducer or Connector: 110 x 54: requires: DCT0136 204 x 60: requires: DCT0520 Comes complete with duct connector DCT0520. Double Airbrick Adaptor Double Airbrick Reducer Dimension (mm) Order Code Dimension (mm) Order Code 220 x 90:232 x 138 DCT1451 235 x 140 DCT1453 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 77 Manrose LOW PROFILE DUCT FITTINGS Wall/Ceiling Plates Rectangular Wall/Ceiling Plates Round External Tube Grille Dimension (mm) Order Code Dimension (mm) Order Code Diameter (mm) Order Code 155 x 155 : 104 ø DCT0148 155 x 155 : 110 x 55 DCT0016 100 DCT2206 170 x 170 : 130 ø DCT0149 264 x 118 : 206 x 60 DCT0528 200 x 200 : 160 ø DCT0150 A External Louvred Grilles Designed to fit directly into round solid tube, for systems ducted straight through an external wall. B Flat Channel Clips *2 clips are required to secure ducting. Diameter (mm) Order Code Dimension (mm) Order Code 100 DCT2200 110 x 54 (A) DCT0134 125 DCT2201 204 x 60 (A) DCT0527 150 DCT2202 220 x 90 (B) DCT1445* 300 x 25 (B) DCT1458* Manrose In-Line Backdraught Shutters PVC METAL Duct Size (mm) Order Code Order Code 100 FAN0213 125 DCT0036 150 DCT0511 200 78 DCT2092 150mm PVC In-Line Backdraught Shutter BRANCH TAKE OFF (B.T.O) POLY INSULATED Duct Size (mm) Order Code Order Code 100-100-100 DCT1439 125-125-125 DCT1501 150-150-150 DCT0091 DCT0875 200-150-150 DCT0719 DCT0876 200-200-150 DCT0460 DCT0877 200-200-200 DCT0461 DCT0878 200-200-200 Branch Take Off • • • • • • Manufactured from HDPE. UV stabilised, Heavy duty, robust. Smooth internal lines, no sharp edges. Positive lock duct tabs. Insulation meets AS 1530 part 3. Insulation material LDPE, thickness 5mm. REDUCERS PVC Duct Size (mm) Order Code 125-100 DCT2067 150-100 DCT2122 150-125 DCT2066 PVC Plastic Duct Joiners/Spigots PVC METAL LONG METAL SHORT METAL PLATE SPIGOTS Duct Size (mm) Order Code Order Code Order Code Order Code 100 DCT0159 125 Metal Long PVC Plastic Metal Short Metal Plate Spigots DCT0037 150 DCT0723 DCT0059 DCT0935 200 DCT0724 DCT0071 DCT0939 250 DCT0725 DCT0339 DCT0940 Note 1. Products with the “order code” showing are generally ex. stock lines - other products are available to order. 2. Combinations of sizes which are not ex. stock can be made up using a suitable body and the relevant reducers and fitting joiners poly. 3. Nude combination fittings will be supplied in component form. We do NOT assemble. 4. Insulated versions may not be ex-stock but will generally be available within 2-3 days of ordering. 5. Should you have an ongoing requirement for an item that is not a standard stock line – PLEASE discuss with us and we will review stocking the item for you. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 79 Manrose Wall/Ceiling Grilles Fixed LOUVRE Duct Size (mm) Colour Order Code 100 White DCT0025 100 Grey DCT0024 100 Terracotta DCT0026 125 White DCT0041 125 Grey DCT0039 125 Terracotta DCT0040 150 White DCT0063 150 Grey DCT0062 150 Terracotta DCT0064 200 White DCT0340 230/250 White DCT0073 300 White DCT1979 150mm Wall/Ceiling Grille Fixed Louvre White • Standard grille with some weather protection. • Removable insert for easy cleaning. Manrose Wall/Ceiling Grilles EGGCRATE Duct Size (mm) Colour Order Code 100 White DCT0375 125 White DCT0472 150 White DCT0473 150mm Wall/Ceiling Grille Eggcrate White • Improved air-flow characteristics. • Removable insert for easy cleaning. DIMENSION INFORMATION Grille Description Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) Fixed Louvre Grille 100 140 x 140 100 35 105 Fixed Louvre Grille 125 162 x 162 122 25 127 Fixed Louvre Grille 150 174 x 174 152 32 157 Fixed Louvre Grille 200 285 x 285 199 67 240 Fixed Louvre Grille 230/250 285 x 285 230 29 240 Fixed Louvre Grille 300 350 x 350 285 50 295 Eggcrate Grille 100 140 x 140 100 34 105 Eggcrate Grille 125 162 x 162 122 24 127 Eggcrate Grille 150 175 x 175 152 34 157 80 Manrose DESIGNER Wall Grilles STAINLESS Gravity Duct Size (mm) Colour Order Code 100 Stainless Steel DCT2145 125 Stainless Steel DCT2146 150 Stainless Steel DCT2147 Manrose Wall Grilles PLASTIC Gravity • High quality designer stainless steel finish. • Stainless Steel Grade 304. Duct Size (mm) Colour Order Code 100 White DCT0029 100 Grey DCT0028 100 Terracotta DCT0027 125 White DCT0044 125 Grey DCT0042 125 Terracotta DCT0043 150 White DCT0066 150 Grey DCT0061 150 Terracotta DCT0065 230/250 White DCT2204 300 White DCT1981 • Prevents back draughts & weather penetration. DIMENSION INFORMATION Grille Description Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) Designer Gravity Grille 100 150 x 150 97 52 115 Designer Gravity Grille 125 180 x 180 120 52 140 Designer Gravity Grille 150 180 x 180 145 62 160 Standard Gravity Grille 100 140 x 140 100 35 105 Standard Gravity Grille 125 162 x 162 122 25 127 Standard Gravity Grille 150 174 x 174 152 32 157 Standard Gravity Grille 230/250 285 x 285 230 29 240 Standard Gravity Grille 300 350 x 350 285 50 295 The Designer Gravity Grille requires a minimum pressure to open. • 20Pa - 100mm (DCT2145). • 30Pa - 125mm (DCT2146). • 30Pa - 150mm (DCT2147). Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 81 Manrose Wall/Ceiling Grilles Low Profile Duct Size (mm) Description Colour Order Code 100 Circular White DCT1089 100 Square White DCT2223 125 Circular White DCT1090 125 Square White DCT2224 150 Circular White DCT1067 150 Square White DCT2225 • • • • • 150mm Low Profile Wall/Ceiling Grille Low Profile eggcrate design improves airflow in extraction applications. Twist lock fascia for easy cleaning. Gib fixing clips included. Longer spigot for easy duct connection. Satin Silver & Chrome fascias available. ACCESSORIES Duct Size (mm) Description Colour Order Code 125 Circular Fascia Satin Silver FAN2069 125 Square Fascia Satin Silver FAN2068 125 Circular Fascia Chrome FAN0757 125 Square Fascia Chrome FAN0755 125 Circular Fascia White FAN0748 125 Square Fascia White FAN0747 150 Circular Fascia Satin Silver FAN2070 150 Square Fascia Satin Silver FAN2071 150 Circular Fascia Chrome FAN0613 150 Square Fascia Chrome FAN0598 150 Circular Fascia White FAN0750 150 Square Fascia White FAN0749 125 Spigot White DCT1074 150 Spigot White FAN0656 150mm Low Profile Wall/Ceiling Grille - Square/Circular Accessories DIMENSION INFORMATION Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) 100 140 98 49 115 125 170 120 65 135 150 200 150 65 165 100 140 x 140 98 49 115 125 161 x 161 120 65 135 150 191 x 191 150 65 165 82 Manrose DESIGNER WALL/CEILING GRILLES SQUARE Duct Size (mm) Colour Order Code 150 White DCT2236 150 Silver DCT2237 • High quality designer finish available in either white or brushed aluminium silver. • Designed for bathroom extraction that blends into any decor. Designer Wall/Ceiling Grilles DIMENSION INFORMATION Duct Size Face Size Spigot Diameter (mm) (mm) (mm) Spigot Length Cut-Out (mm) Size (mm) 150 191 x 191 150 65 157 150 191 x 191 150 65 157 Manrose WALL/CEILING GRILLES CIRCULAR Duct Size (mm) Colour Order Code 100 White DCT2185 125 White DCT2186 150 White DCT2187 • Concentric circular grille designed for extraction. 150mm Circular Wall/Ceiling Grille DIMENSION INFORMATION Duct Size (mm) Face Size (mm) 100 140 125 150 Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) 98 49 105 170 125 65 125 200 150 65 157 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 83 Manrose DESIGNER Ceiling Diffuser STAINLESS STEEL Duct Size (mm) Colour Order Code 100 Stainless DCT2139 125 Stainless DCT2140 150 Stainless DCT2141 • High quality designer stainless steel finish - grade 304, Designed for internal extraction where a quality finish is required. Designer Ceiling Diffuser DIMENSION INFORMATION Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length Cut-Out Size (mm) (mm) 100 140 97 52 105 125 172 120 52 130 150 220 145 62 150 Manrose Flat Ceiling Diffuser Low Profile Duct Size (mm) Colour Order Code 150 White DCT2208 • High quality designer finish. • Designed to supply air into your home, by pushing the air along the ceiling and down the walls. Included in Simx Home Ventilation Systems. DIMENSION INFORMATION Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) 150 220 148 80 210 84 Flat Ceiling Diffuser Ceiling DIFFUSER CONE CENTRE Duct Size (mm) Colour Order Code 150 White DCT1472 200 White DCT1473 250 White DCT1474 300 White DCT1475 • • • • • • • • Manufactured from ABS plastic. Designed for either supply or extract ventilation. When used to supply, the air will be pushed down into the room. These diffusers are used in heat transfer systems. Spring loaded fixing clips. Resistant to scratching and fading. Positive lock duct tabs. Adjustable screw in centre cone to ensure a balanced airflow. 200mm Ceiling Diffuser DIMENSION INFORMATION Duct Size (mm) Face Size Spigot (mm) Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) 150 266 150 95 232 200 317 200 95 282 250 389 250 102 355 300 400 300 102 405 EGGCRATE ROUND DIFFUSER Duct Size (mm) Colour Damper Order Code 150 Ice White - DCT2594 200 Ice White - DCT2595 150 Ice White included DCT2608 200 Ice White included DCT2609 • • • • • Manufactured from ABS plastic. Designed for either supply or extract ventilation. Spring loaded fixing clips. Resistant to scratching and fading. Positive lock duct tabs. 150mm Eggcrate Round Diffuser DIMENSION INFORMATION Duct Size (mm) Face Size Spigot (mm) Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) 150 240 150 95 215 200 290 200 95 260 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 85 CEILING DIFFUSER ECO Diffuser Ceiling Diffusers Duct Size (mm) Colour Order Code 100 White DCT0020 ng system is an investment in your families personal comfort. As 125 White DCT0174 e placed on the type of ancillary products as to the type of unit 150 White DCT0058 200 White DCT0068 s are manufactured from ABS (Acrylonitrile Butadiene Styrene) • Manufactured from A.B.S plastic. type of plastic that is used products like fridge • Designed for in either supply ortelephones, extract ventilation. • Fixing flange included, screws required. • Adjustable screw in centre cone. outside flange gives an attractive and unobtrusive finish. It is the 200mm Ceiling ‘ECO’ Diffuser s used on our other plastic diffusers. So when you purchase DIMENSION INFORMATION products, you get a job that is aesthetically pleasing throughout st. Cone Centres are designed to suit the reverse cycle systems. Cone Centres allow adjustable control of the airflow by moving the centre up or down. This is achieved by a screwing technique. Clockwise decreases and shallows Unijet Cross Section the airflow while anti-clockwise increases and deepens the airflow. ed not to just ke other Duct Size Face Size (mm) Spigot Diameter Spigot Length (mm) (mm) Cut-Out Size (mm) 100 149 99 47 98 125 169 125 47 123 et disperses(mm) because it’s gles. mperature 150 186 148 50 148 200 235 198 50 198 Cone Centre Cross Section Cone Centre Cross Section d to suit the ne Centres f the airflow r down. This technique. shallows the se increases Shallow Airflow Deep Airflow poor quality remains long after the a low price has been forgotten. ty Ltd ABN 21 005 072 873 Heidelberg West 86Victoria Australia 3081 t Heidelberg Victoria 3081 Australia 1 (0)3 9458-3120 email sales@westaflex.com.au & New Zealand Manrose DESIGNER Weatherproof COWLS STAINLESS COWLS Duct Size (mm) Colour Order Code 100 Stainless Steel DCT2151 125 Stainless Steel DCT2152 150 Stainless Steel DCT2153 • High quality designer stainless steel finish. • Designed for use where adverse weather conditions are experienced. • Manufactured from a Stainless Steel Grade 304. 150mm Weatherproof Cowl Manrose Weatherproof COWLS PLASTIC COWLS Duct Size (mm) Colour Order Code 100 White DCT0018 100 Brown DCT0019 125 White DCT1030 150 White DCT1031 150mm Weatherproof Plastic Cowl • Used where adverse weather conditions are experienced. • 150mm Cowl, now includes mesh as standard DIMENSION INFORMATION Grille Description Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) Designer Weatherproof 100 150 x 150 97 52 115 Designer Weatherproof 125 180 x 180 120 52 140 Designer Weatherproof 150 180 x 180 145 62 160 Standard Weatherproof 100 140 x 140 99 35 115 Standard Weatherproof 125 175 x 175 124 27 140 Standard Weatherproof 150 175 x 175 152 35 165 The Designer Weatherproof Cowl requires a minimum pressure to open. • 10Pa - 100mm (DCT2151). • 10Pa - 125mm (DCT2152). • 10Pa - 150mm (DCT2153). Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 87 Manrose DESIGNER Weatherproof Dome STAINLESS DOME Cowls Duct Size (mm) Colour Order Code 100 Stainless Steel DCT2157 125 Stainless Steel DCT2158 150 Stainless Steel DCT2159 • • • • • High quality stainless steel dome cowl for a modern stylish look. Designed for exhaust and supply ventilation. Generally mounted on an external wall, however they can be mounted internally. Manufactured from a Stainless Steel Grade 304. Insect mesh included. dimension information Duct Size (mm) Face Size (mm) Spigot Diameter (mm) Spigot Length (mm) Cut-Out Size (mm) Designer Dome Cowl 100 140 97 52 115 Designer Dome Cowl 125 180 120 52 140 Designer Dome Cowl 150 200 145 62 155 Grille Description 88 150mm Weatherproof Stainless Dome Cowl Manrose Wall/Ceiling PLATE GRILLES Fixed Louvre Vent Plate Size (mm) Colour Order Code 245 x 80 White DCT2194 245 x 80 Chrome DCT2195 245 x 160 White DCT2196 245 x 160 Chrome DCT2197 245 x 245 White DCT2198 245 x 245 Chrome DCT2199 Wall/Ceiling Plate Grilles Fixed Louvre Vent Adjustable Vent Plate Size (mm) Colour Order Code 245 x 80 White DCT2188 245 x 80 Chrome DCT2189 245 x 160 White DCT2190 245 x 160 Chrome DCT2191 245 x 245 White DCT2192 245 x 245 Chrome DCT2193 • • • • Manufactured from PVC in either white or chrome. Designed for use when make-up air is required. Fixed Louvre provides maximum airflow. Adjustable Vent can be fully closed off when not required. Wall/Ceiling Plate Grilles Adjustable Vent Manrose Wall/Ceiling PLATE GRILLES PLATE FACE Duct Size (mm) Grille Type Colour Order Code 150 Fixed Louvre White DCT0352 150 Gravity Shutter White DCT0353 230 Fixed Louvre DCT0354 White • For situations where no spigot is required. Manrose Door GRILLE Wall/Ceiling Plate Grilles Plate Face Model No. Description Order Code Door Vent Internal Door Ventilator Grille FAN0159 • This door grille allows make-up air into the room. • Dimensions: 455mm (h) x 90mm (w) to fit door with depth of 33mm. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 89 Roof Cowls Duct Size (mm) Description Order Code 150 General Purpose Cowl DCT0708 150 Heavy Duty Cowl DCT0709 150mm General Purpose Cowl • General Purpose Cowl - Low profile. • Low back pressure. - Added exhaust aperture area and deep vent coverage. - Recommended where high winds in exposed locations may drive rain into the vent. - Also recommended for use in high airflow air intake systems to prevent rain being sucked into the system. 150mm Heavy Duty Cowl DIMENSION INFORMATION (mm) Models A B DCT0708 275 125 DCT0709 275 140 Performance - DCT0708/DCT0709 DCT0708 and DCT0709 Pressure vs Volume A 100 Pressure (Pa) 80 B 60 40 20 0 0 50 100 150 Volume (litre/sec) 90 A 200 250 B Roof Cowl Kits with Flashing & HDPE Tube Duct Size (mm) Description Order Code 150 General Purpose Kit DCT0172 150 Heavy Duty Cowl Kit DCT0710 150 General Purpose Lead Flashing Kit DCT1095 • • • • • General purpose cowl included. 0.5m HDPE Tube included. Flashing included (for metal based roofs). All fittings supplied. Optional lead Flashing available (extra cost). 150mm General Purpose Kit Note: Lead Flashing (DCT0190) required for concrete tile roofs. Plastic Reducers for HDPE Thru-Roof Tube (for thru-roof kits) Metric Size (mm) Description Order Code 150:125 150:125 reducer DCT2066 150:100 150:100 reducer DCT2122 • Reducers fit to the bottom of HDPE tube to adapt to smaller duct diameters where required. Manrose Angled Roof Cowl Kit Duct Size (mm) Description Order Code 125 Angled Roof Kit DCT2205 • • • • General purpose through roof kit for smaller applications. 110mm PVC pipe - suitable for 125mm flexible ducting. To be mounted on tile roofs. Kit includes - Cowl, 0.5m of tube & weathering slate included. Angled Roof Kit Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 91 Manrose rangehood ducting kits • • • There are three ducting options available, for the kitchen rangehood. Through an adjacent wall, through the soffit (under the eave) or up through the roof. Semi-Rigid ducting is used in our top of the range systems to reduce the rangehood system noise and increase air flow performance. Fully complies to AS/NZS 60335.2.80. Thru Wall rangehood DUCTING Kits Duct Size (mm) Description Order Code 125 Rear Vent - Gravity Grille DCT1162 150 Top & Rear Vent Weatherproof Cowl DCT2592 • For added weather protection use the weatherproof cowl as included in DCT2592. Soffit rangehood DUCTING Kits Duct Size (mm) Description Order Code 150 Thru Soffit DCT1161 150 Thru Soffit - Galv Tube DCT1259 150 Thru Soffit - Semi Rigid DCT2323 • All systems include 3 metres of Aluminium Duct. • Galv Tube system also includes 900mm of Solid Tube. Thru ROOF rangehood DUCTING Kits Duct Size (mm) Description Order Code 150 Thru Roof - Iron DCT2324 150 Thru Roof - Tiled DCT2325 FLASHING Iron Roof 92 Tiled Roof Manrose Dryer Ducting Kit Rear Vent Thru Wall Duct Size (mm) Order Code 100 DCT1263 Kit Includes: • • • • • 3m Flexible aluminium Aluduct (rated -30°C to 150°C). 0.75m Flat channel duct. 2 x Rectangular to Round 90° elbow bends. 100mm white eggcrate grille. All fixing and fittings. Dryer Ducting Kit Dryer Ducting features • • • This ducting kit is designed for inverted and wall mounted dryers. Free standing dryers on the floor will require extra rectangular ducting and connector (Order Code: DCT0013 & DCT0014). These ducting kits suit dryers with a 100mm outlet. The square to round elbow will fit snugly onto most 100mm dryer outlets. Pro Series Extension Kit Duct Size (mm) Description Order Code 150 Heat Trans Extension Kit DCT2101 150 SimxHome Extension Kit DCT2276 Kit Includes: • • • • • Designed to extend your home ventilation or heat transfer systems to additional rooms. 1 x Y-Branch. 1 x 3 metres - 150mm Acoustic Insulated Ducting. 1 x Adjustable Circular Diffuser. All fixing and fittings included. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 93 Manrose Accessories insect mesh Duct Size (mm) Description Order Code 100 For 100mm Grilles DCT0371 125 For 125mm Grilles DCT0208 150 For 150mm Grilles DCT0207 250 For 200mm & 250mm Grilles DCT0373 150 Bird Mesh DCT2263 Insect Mesh Accessory Duct Straps and Duct Tape Duct Size (mm) Description Order Code 100mm Ducting Strap FAN0274 125mm Ducting Strap FAN0281 150mm Ducting Strap FAN0282 12mm x 3m Hanging Strap DCT2299 25mm x 50m Hanging Strap DCT0808 48mm x 5m Duct Tape DCT0173 48mm x 30m Duct Tape DCT0807 48mm x 60m Duct Tape - *AS4254 DCT1132 Ducting Straps & Duct Tape AS4254 Duct Tape *AS4254 Duct tape DCT1132 - Temperature range -37°C - 127°C Roof Flashings Description Order Code Flashing Roof Flashing - fits 110-160mm DCT0180 Tiledek Roof Flashing - For use on concrete tile, clay tile and slate roofing DCT0190 0.5m HDPE Tube 150mm DCT0183 Stitching Screws (for roof fastening) FAN0400 94 Roof Flashings Heat Trans Systems HEAT TRANS uses excess heat to warm other areas of the home by transferring it from one room to multiple rooms. Heat Trans is the professional brand in heat transfer systems and is the brand of choice for electrical contractors. Leading the market for over 15 years, Heat Trans is at the forefront of product development and innovation and the only heat transfer systems using acoustic insulated ducting and digital controllers. How does Heat Trans work 01 02 03 Excess heat from your heat source will rise to ceiling level where it is trapped. This excess heat can reach temperatures of 30-35°C. This excess heat can be effectively transferred to other rooms using a high quality fan and acoustic insulated ducting. Air moves from the bedrooms back to the lounge creating a natural recirculation of warm air throughout the home. This will also make your home healthier by helping to reduce mould and mildew. MODELS MODEL Order Code Heat Trans One Room Kit FAN0325 Heat Trans Two Room Kit FAN0337 Heat Trans Three Room Kit FAN0338 Pro-Series One Outlet Extension Kit DCT2101 Heat Trans Summer-Vent Extension Kit DCT1481 Heat Trans Thru Wall Kit FAN0005 Heat Trans systems utilise excess heat throughout the home and cost as little as a light bulb to run. Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 95 Heat Trans Systems One Room Kit Outlet Size Description 150mm Fan Speeds Heat Trans One Room Kit Order Code 1 FAN0325 Kit includes: • • • • • • 1 x Ultecon Digital Thermostat Controller. 1 x 150mm High Performance Axial Flow Fan. 2 x 3 Metres - 150mm Acoustic Insulated Ducting. 1 x Circular Inlet Grille. 1 x Adjustable Circular Design Outlet Diffuser. All Fittings and Fixings Included. Two Room Kit Outlet Size Description 150mm Heat Trans Two Room Kit Fan Speeds Order Code 2 FAN0337 Kit includes: • • • • • • • 1 x Ultecon Digital Thermostat/ Fan Speed Controller 1 x 150mm Multi-Speed High Performance Fan. 4 x 3 Metres - 150mm Acoustic Insulated Ducting. 1 x Branch Take-Off (Splitter). 1 x Circular Inlet Grille. 2 x Adjustable Circular Design Outlet Diffusers. All Fittings and Fixings Included. Three Room Kit Outlet Size Description 150mm Heat Trans Three Room Kit Fan Speeds 3 Order Code FAN0338 Kit includes: • • • • • • • • 96 1 x Ultecon Digital Thermostat/ Fan Speed Controller. 1 x 200mm Multi-Speed High Performance Fan. 3 x 3 Metres - 150mm Acoustic Insulated Ducting. 2 x 3 Metres - 200mm Acoustic Insulated Ducting. 1 x Double Branch Take-Off (Three Way Splitter). 1 x Circular Inlet Grille. 3 x Adjustable Circular Design Outlet Diffusers. All Fittings and Fixings Included. Heat trans Features The Ultecon digital thermostat controller measures and displays the temperature of your lounge and lets you preset your preferred room temperature. When your lounge temperature exceeds your preferred room temperature the system will automatically start to transfer the excess heat to other rooms in your home. The 2 and 3 room systems also offer fan speed control, which allows you to set your preferred fan speed giving you ultimate control over the volume of heated air being transferred. Superior Fans High quality multi-speed fans for optimum airflow ventilation in the home that cost as little as a light bulb (between 70W and 120W) to run. These high quality fans have been specifically selected to ensure correct airflow and pressure levels are achieved. Whisper quiet The unique acoustic insulated ducting reduces air transfer noise to a ‘whisper quiet’ level. Better temperature retention is achieved, ensuring optimal heat transfer of excess warm air. One Room Controller Adjustable diffusers Easily adjustable to allow balancing of the airflow into each room. Simply twist the centre section of the diffuser to allow more or less air into each room. Or simply close any diffuser when the room is not in use. Optional extras Two/Three Room Controller Summer feature Introduce fresher cooler air into your home in summer with the Summer-Vent Extension Kit, to enable year round use of your system. With the inlet grille installed under your soffit, fresher cooler air is filtered using a high efficiency F7 filter and is distributed throughout your home via your Heat Trans outlets. The system is controlled via a standard wall switch which operates the motorised damper to start drawing air from outside. Note: When the summer feature is working the lounge warmed room inlet is switched off via the damper and will not receive the cooled air directly from outside, however due to air pressure a natural re-circulation occurs throughout the home. Summer Feature Extension Kit Extension kit The Pro-Series One Outlet Extension Kit is designed to extend your standard three room Heat Trans system so you can distribute warm air to an extra room within your home. The extension kit gives you the flexibility to add additional outlet/s to your Heat Trans system. By adding additional outlet/s to your system you are simply dividing the available heated air amongst more rooms. Note: All Heat Trans kits can be extended. 1 Room kits can be extended to a max length of 12 metres ( 6 metres supplied in kit). 2 Room kits can be extended to a max length of 21 metres (12 metres supplied in kit). 3 Room kits can be extended to a max length of 24 metres (15 metres supplied in kit). Pro-Series One Outlet Extension Kit Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 97 Alpha-Numeric index Order codes DCT0013 75 DCT0126 76 DCT0358 72 DCT0525 76 DCT1161 92 DCT0014 76 DCT0127 76 DCT0359 72 DCT0526 76 DCT1162 92 DCT0015 77 DCT0131 76 DCT0360 40 DCT0527 78 DCT1164 73 DCT0016 78 DCT0134 78 DCT0362 40 DCT0528 78 DCT1169 40 DCT0018 87 DCT0136 76 DCT0366 40 DCT0633 73 DCT1171 40 DCT0019 87 DCT0137 77 DCT0367 72 DCT0634 73 DCT1176 73 DCT0020 86 DCT0145 75 DCT0368 72 DCT0635 73 DCT1216 73 DCT0024 80 DCT0146 75 DCT0369 72 DCT0636 73 DCT1224 73 DCT0025 80 DCT0147 75 DCT0370 72 DCT0708 90 DCT1259 92 DCT0026 80 DCT0148 78 DCT0371 94 DCT0709 90 DCT1263 93 DCT0027 81 DCT0149 78 DCT0373 94 DCT0710 91 DCT1268 73 DCT0028 81 DCT0150 78 DCT0375 80 DCT0719 79 DCT1414 77 DCT0029 81 DCT0151 75 DCT0377 72 DCT0723 79 DCT1424 75 DCT0036 78 DCT0152 75 DCT0380 72 DCT0724 79 DCT1425 75 DCT0037 79 DCT0153 75 DCT0399 72 DCT0725 79 DCT1426 75 DCT0039 80 DCT0159 79 DCT0400 72 DCT0807 94 DCT1439 79 DCT0040 80 DCT0172 91 DCT0401 72 DCT0808 94 DCT1440 77 DCT0041 80 DCT0173 94 DCT0402 72 DCT0833 73 DCT1441 77 DCT0042 81 DCT0174 86 DCT0403 72 DCT0834 73 DCT1442 76 DCT0043 81 DCT0180 94 DCT0404 72 DCT0835 73 DCT1443 75 DCT0044 81 DCT0183 94 DCT0405 72 DCT0836 73 DCT1444 77 DCT0058 86 DCT0189 56 DCT0406 72 DCT0875 79 DCT1445 78 DCT0059 79 DCT0190 94 DCT0409 72 DCT0876 79 DCT1446 76 DCT0061 81 DCT0207 94 DCT0410 72 DCT0877 79 DCT1447 76 DCT0062 80 DCT0208 94 DCT0411 72 DCT0878 79 DCT1448 76 DCT0063 80 DCT0328 72 DCT0412 72 DCT0935 79 DCT1450 77 DCT0064 80 DCT0329 72 DCT0413 72 DCT0936 74 DCT1451 77 DCT0065 81 DCT0330 72 DCT0414 72 DCT0937 74 DCT1452 76 DCT0066 81 DCT0331 72 DCT0415 72 DCT0938 74 DCT1453 77 DCT0068 86 DCT0332 72 DCT0416 72 DCT0939 79 DCT1455 76 DCT0071 79 DCT0333 74 DCT0417 72 DCT0940 79 DCT1456 76 DCT0073 80 DCT0334 74 DCT0418 72 DCT0953 75 DCT1458 78 DCT0088 72 DCT0335 74 DCT0460 79 DCT0954 75 DCT1459 76 DCT0089 72 DCT0336 74 DCT0461 79 DCT1030 87 DCT1460 75 DCT0091 79 DCT0337 74 DCT0472 80 DCT1031 87 DCT1461 76 DCT0114 74 DCT0338 74 DCT0473 80 DCT1067 82 DCT1472 85 DCT0115 74 DCT0339 79 DCT0477 74 DCT1074 82 DCT1473 85 DCT0116 74 DCT0340 80 DCT0511 78 DCT1076 82 DCT1474 85 DCT0117 74 DCT0343 72 DCT0519 75 DCT1089 82 DCT1475 85 DCT0118 74 DCT0344 72 DCT0520 76 DCT1090 82 DCT1479 76 DCT0119 74 DCT0352 89 DCT0521 77 DCT1095 91 DCT1480 77 DCT0120 74 DCT0353 89 DCT0522 77 DCT1097 61 DCT1481 95 DCT0124 77 DCT0354 89 DCT0523 77 DCT1114 76 DCT1482 76 DCT0125 76 DCT0357 72 DCT0524 76 DCT1132 94 DCT1501 79 98 Alpha-Numeric index Order codes DCT1519 38 DCT2196 89 FAN0055 24 FAN0282 94 FAN0519 28 DCT1520 38 DCT2197 89 FAN0060 46 FAN0325 95 FAN0520 28 DCT1521 38 DCT2198 89 FAN0061 46 FAN0325 96 FAN0521 28 DCT1522 38 DCT2199 89 FAN0064 36 FAN0326 48 FAN0529 56 DCT1979 80 DCT2200 78 FAN0065 36 FAN0327 48 FAN0530 56 DCT1981 81 DCT2201 78 FAN0071 14 FAN0328 36 FAN0531 56 DCT2066 79 DCT2202 78 FAN0072 14 FAN0329 36 FAN0532 56 DCT2066 91 DCT2204 81 FAN0074 14 FAN0330 50 FAN0533 56 DCT2067 79 DCT2205 91 FAN0075 14 FAN0337 95 FAN0534 56 DCT2092 78 DCT2206 78 FAN0080 24 FAN0337 96 FAN0535 56 DCT2095 77 DCT2208 84 FAN0082 24 FAN0338 95 FAN0589 12 DCT2096 77 DCT2223 82 FAN0083 24 FAN0338 96 FAN0590 12 DCT2097 76 DCT2224 82 FAN0085 44 FAN0346 16 FAN0591 12 DCT2098 76 DCT2225 82 FAN0090 46 FAN0348 16 FAN0594 12 DCT2099 76 DCT2236 83 FAN0091 46 FAN0355 26 FAN0595 12 DCT2101 93 DCT2237 83 FAN0101 36 FAN0357 50 FAN0596 12 DCT2101 95 DCT2263 94 FAN0102 36 FAN0358 50 FAN0598 12 DCT2120 40 DCT2276 93 FAN0107 26 FAN0360 50 FAN0598 22 DCT2121 40 DCT2299 94 FAN0109 26 FAN0361 50 FAN0598 82 DCT2122 79 DCT2323 92 FAN0110 26 FAN0372 62 FAN0604 12 DCT2122 91 DCT2324 92 FAN0119 14 FAN0374 16 FAN0605 12 DCT2139 84 DCT2325 92 FAN0120 14 FAN0397 60 FAN0606 12 DCT2140 84 DCT2592 92 FAN0121 14 FAN0400 94 FAN0609 12 DCT2141 84 DCT2594 85 FAN0122 14 FAN0405 46 FAN0610 12 DCT2145 81 DCT2595 85 FAN0123 14 FAN0406 46 FAN0611 12 DCT2146 81 DCT2608 85 FAN0124 14 FAN0409 24 FAN0613 12 DCT2147 81 DCT2609 85 FAN0126 14 FAN0410 24 FAN0613 22 DCT2151 87 FAN0005 95 FAN0127 14 FAN0411 24 FAN0613 82 DCT2152 87 FAN0012 46 FAN0135 24 FAN0412 60 FAN0614 22 DCT2153 87 FAN0013 46 FAN0136 24 FAN0413 60 FAN0615 22 DCT2157 88 FAN0015 63 FAN0137 24 FAN0420 40 FAN0616 34 DCT2158 88 FAN0016 63 FAN0138 24 FAN0431 38 FAN0617 34 DCT2159 88 FAN0017 36 FAN0140 24 FAN0431 40 FAN0618 34 DCT2185 83 FAN0018 36 FAN0141 24 FAN0438 40 FAN0619 34 DCT2186 83 FAN0021 26 FAN0146 28 FAN0452 26 FAN0620 22 DCT2187 83 FAN0038 20 FAN0148 28 FAN0455 16 FAN0621 22 DCT2188 89 FAN0041 20 FAN0153 63 FAN0467 50 FAN0623 22 DCT2189 89 FAN0042 20 FAN0155 63 FAN0481 28 FAN0625 61 DCT2190 89 FAN0044 14 FAN0156 63 FAN0482 28 FAN0626 61 DCT2191 89 FAN0046 14 FAN0157 63 FAN0499 20 FAN0644 82 DCT2192 89 FAN0047 14 FAN0159 89 FAN0501 20 FAN0656 82 DCT2193 89 FAN0048 14 FAN0213 78 FAN0504 20 FAN0685 61 DCT2194 89 FAN0053 24 FAN0274 94 FAN0505 20 FAN0686 61 DCT2195 89 FAN0054 24 FAN0281 94 FAN0518 28 FAN0690 61 Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au 99 Alpha-Numeric index Order codes FAN0691 61 FAN1053 42 FAN2127 42 FAN0732 22 FAN1060 56 FAN2162 30 FAN0735 22 FAN1096 63 FAN2200 30 FAN0738 22 FAN2029 38 FAN2205 103 FAN0739 56 FAN2030 38 FAN2206 103 FAN0740 56 FAN2031 38 FAN2213 102 FAN0748 82 FAN2032 38 FAN2214 102 FAN0750 82 FAN2033 38 FAN2229 104 FAN0755 12 FAN2034 38 FAN2230 104 FAN0755 22 FAN2035 38 FAN2286 58 FAN0755 82 FAN2036 38 FAN2287 58 FAN0757 12 FAN2037 40 FAN2303 54 FAN0757 22 FAN2038 40 FAN2402 62 FAN0757 82 FAN2040 16 FAN2423 54 FAN0803 40 FAN2040 16 FAN2424 54 FAN0804 40 FAN2041 16 FAN2425 54 FAN0827 40 FAN2042 16 FAN2426 54 FAN0829 52 FAN2043 16 FAN2444 62 FAN0830 52 FAN2049 32 FAN2465 18 FAN0841 60 FAN2050 32 FAN2902 58 FAN0884 18 FAN2051 32 FAN2903 58 FAN0885 18 FAN2066 48 FAN4395 58 FAN0916 44 FAN2067 48 FAN4396 58 FAN0921 49 FAN2068 12 FAN4397 58 FAN0940 30 FAN2068 22 LHT0081 30 FAN0963 62 FAN2068 82 LHT0140 30 FAN0967 56 FAN2069 12 FAN0981 63 FAN2069 22 FAN0982 63 FAN2069 82 FAN0983 63 FAN2070 12 FAN0995 30 FAN2070 22 FAN0997 49 FAN2070 82 FAN1002 56 FAN2071 12 FAN1004 42 FAN2071 22 FAN1005 42 FAN2071 82 FAN1006 42 FAN2076 40 FAN1007 42 FAN2078 46 FAN1009 56 FAN2101 38 FAN1014 30 FAN2101 40 FAN1015 30 FAN2101 62 FAN1043 60 FAN2104 63 FAN1048 42 FAN2124 42 FAN1050 42 FAN2125 42 FAN1051 42 FAN2126 42 100 Energy Efficient Ventilation Solutions Lo-Carbon Lo-Carbon fans from Vent-Axia offer up to 70% energy savings by utilising market leading motor technology, to help reduce your carbon footprint. Lo-Carbon Thomas & Betts are proud to be the distributor of the Vent-Axia Lo-Carbon range of ventilation fans. MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens. Vent-Axia Lo-Carbon long life motors last 5 times longer than conventional AC motors. The extended life of the Lo-Carbon fans is due to the use of a new generation of high quality ball bearing motor. These high quality ventilation fans are specifically designed for bathrooms, extracting moisture laden air quietly & effectively. Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141 Western Australia South Australia Unit 2, 22 Hammond Rd Cockburn Central WA 6164 86A Richmond Rd Keswick SA 5035 Victoria Queensland 2/13-15 Brough St Springvale VIC 3171 26 Turbo Drive Cooparoo QLD 4151 Tasmania Newcastle Electrical Agencies 4 Linear Court Moonah TAS 7009 Nick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322 National Support Centre Phone: 1300 666 595 Fax: 1300 666 594 Email: austsales@tnb.com Web: www.manrose.com.au Energy Efficient Ventilation Solutions 67% en savin ergy g The distributors of Manrose Ventilation fans are proud to distribute the Vent-Axia Lo-Carbon range. These fans offer up to 70% energy savings, utilising market leading motor technology, which lasts considerably longer than conventional AC motors. These high quality ventilation fans are specifically designed to extract moisture-laden air quietly and efficiently. The Vent-Axia Lo-Carbon range includes solutions for wall, ceiling, window and roof mounted applications. With energy savings in mind these models operate efficiently at lower wattage levels, the Silhouette LCS150 for example operates at 8.2W as opposed to a standard ceiling fan which operates at 25W, a saving of 67%. Lo-Carbon VENT-AXIA LO CARBON vent-a-light fan 100 VENT-A-Light Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 70% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearing motors. 100mm Lo Carbon axial in-line shower fan and light kit. Suitable for shower enclosures and wet areas. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. • Low Power consumption - 70% energy savings. • Complete with 3m flexible ducting, white grille and light transformer. • 1 of 2 speeds selectable at installation. • High quality ball bearing motors. • Modern aesthetics, includes blue neon “on light”. • Fan IPX4 rated. • 5 Year Warranty. 70% sav energy ing s Performance Size (mm) Model No. 100 Vent-a-light B 100 Vent-a-light T Extract Performance* Watts Sound (m3/hr) (l/s) (W) dB(A) @3m Lo-Carbon Vent-a-Light Standard 110 31 6.5 +35 23 FAN2229 Lo-Carbon Vent-a-Light Timer 110 31 6.5 +35 23 FAN2230 Description * 1 of 2 speeds selectable at installation * Please note the energy savings only apply to the fan motor, there is still a 35W centre lamp. Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery. Order Code VENT-AXIA LO CARBON wall/ceiling mounted fans Silhouette® 150 Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 67% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearing motors. With a slim profile of only 19mm, Silhouette blends in with the wall surface to provide an unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run to exhaust outside. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. • 19mm stylish low profile grille. • Low Power consumption - 67% energy savings. • Downstream airflow guide vanes for improved pressure development. • 1 of 2 speeds selectable at installation. • High quality ball bearing motors. • Modern aesthetics, includes blue neon ‘on light’. • Fan IPX4 rated. • 5 Year Warranty. 67% sav energy ing s Performance Extract Performance* Watts Sound Size (mm) Model No. Description 150 LCS150B 150 LCS150T (m3/hr) (l/s) (W) dB(A) @3m Lo-Carbon Wall/Ceiling Silhouette Standard 165 46 5 35 241 67 8.2 43 Lo-Carbon Wall/Ceiling Silhouette Timer 165 46 5 35 241 67 8.2 43 Order Code FAN2213 FAN2214 * 1 of 2 speeds selectable at installation Wattage Comparison Size (mm) Model No. Description Wattage 150 XFLP150 Manrose Pro-Series Wall/Ceiling Fan 25W 150 LCS150 Vent-Axia Lo-Carbon Wall/Ceiling Fan 8.2W Energy Savings 16.8W 67% ENERGY SAVINGS Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery. 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. Thomas & Betts | www.manrose.com.au | austsales@tnb.com.au VENT-AXIA LO CARBON wall/ceiling mounted fans Silhouette® 100 Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 63% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearing motors. With a slim profile of only 17mm, Silhouette blends in with the wall surface to provide an unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run to exhaust outside. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. • 17mm stylish low profile grille. • Low Power consumption - 63% energy savings. • Downstream airflow guide vanes for improved pressure development. • 1 of 2 speeds selectable at installation. • High quality ball bearing motors. • Modern aesthetics, includes blue neon “on light”. • Fan IPX4 rated. • 5 Year Warranty. 63% sav energy ing s Performance Extract Performance* Watts Sound Size (mm) Model No. Description 100 LCS100B 100 LCS100T (m3/hr) (l/s) (W) dB(A) @3m Lo-Carbon Wall/Ceiling Silhouette Standard 95 26 7.5 34 60 16 3.4 38 Lo-Carbon Wall/Ceiling Silhouette Timer 95 26 7.5 34 60 16 3.4 38 Order Code FAN2205 FAN2206 * 1 of 2 speeds selectable at installation Wattage Comparison Size (mm) Model No. Description Wattage 100 XF100 Manrose Wall/Ceiling Fan 20W 100 LCS100 Vent-Axia Lo-Carbon Wall/Ceiling Fan 7.5W Energy Savings 12.5W 63% ENERGY SAVINGS Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery.