eW Blast Powercore The world’s leading exterior LED wash fixture with solid white light eW Blast Powercore The world’s leading exterior LED wash fixture with intelligent white light eW Blast Powercore is an LED lighting fixture providing a high-intensity wash of white light while consuming less energy than comparable non-LED light fixtures. Rated for outdoor use, eW Blast Powercore offers the efficiency and cost-effectiveness of Powercore technology in a rugged die-cast aluminum housing. eW Blast Powercore is ideal for applications as diverse as highlighting architectural features, general site illumination, and lighting signage and retail spaces. • Integrates patented Powercore technology — Powercore technology rapidly, efficiently, and accurately controls power output to eW Blast Powercore fixtures directly from line voltage, supporting long fixture runs and eliminating the need for external power supplies. Contractorfriendly installation using standard mounting and wiring dramatically simplifies installation and helps lower total system cost. • Supports new applications for white light — With long useful source life (up to 70,000 hours at 70% lumen maintenance), eW Blast Powercore can significantly reduce or eliminate maintenance problems, allowing the use of white lighting in spaces where lamp maintenance may be impossible. For example, you can effectively illuminate building features from positions accessible only by crane. • High-intensity, energy-efficient white light — With an output of up to 2390 lumens, eW Blast Powercore offers high-intensity illumination at a significantly lower power draw than comparable non-LED fixtures. • Versatile lighting options — eW Blast Powercore is available in four beam angles: 21° and 36° for soft edges, 83° with no optic for uniformly washing façades, and 10° for extended light projection. Rugged die-cast aluminum housing is available in white or black. • Flexible light positioning — Fixtures can be mounted to a junction box on a wall, ceiling, or floor for maximum flexibility. Locking base swivel offers friction-free rotation of up to 350°, and 110° fixture tilting provides quick fixture positioning without special tools. • Support for multiple voltages — eW Blast Powercore accepts power input of 100, 120, 240, and 277 VAC, allowing installation and operation from line voltage in a variety of locations. • Dimming capability — Patented DIMand technology offers smooth dimming capability with selected commercially available reverse-phase ELV-type dimmers. Outdoor Rated Fully sealed for maximum fixture life, eW Blast Powercore fixtures meet or exceed specifications for use in wet locations. 2 eW Blast Powercore Product Guide The Arrival of White LED Lighting for General Illumination Retrofitting Boston’s Marriott Custom House Tower In 2008, Boston’s first official skyscraper, the Marriott Custom House Tower, shown here and on the cover, underwent a long-awaited lighting redesign that restores its prominence on the Boston skyline in a smart and sustainable way. Formerly lit by incandescent-based fixtures that had fallen into disrepair, the tower was restored using energy-efficient, low-maintenance white LED fixtures from Philips. A combination of 125 eW Blast Powercore and eW Graze Powercore fixtures now fully illuminate the tower from the 17th floor to the peak. Photography: John Brandon Miller Photography Cost-Effective, Energy-Efficient, and Easy to Maintain Not only do the LED fixtures in the installation consume just one third the energy of the previous incandescent sources, the LED sources that they use have a projected useful life of more than 20 years at six hours of use per day, requiring far less maintenance. Lighting Design: Lam Partners Photography: Brad Koerner By incorporating Powercore technology to directly accept line voltage, the fixtures eliminate the special cabling and external low-voltage power supplies that other LED lighting fixtures require. Because they use standard wiring and power sources, the lighting designers were able to easily replace the former incandescent light fixtures one-for-one in their existing locations and mountings. New Possibilities for White LED Lighting The efficiency and long source life of eW Blast Powercore and other Philips white LED fixtures open up new possibilities for sustainable architectural lighting. As the Custom House Tower installation shows, in dramatic and elegant fashion, white LED lighting has arrived as a viable, energy-efficient alternative for general illumination. eW Blast Powercore Product Guide 3 Photometrics Photometric data is based on test results from an independent NIST traceable testing lab. IES data is available at www.philipscolorkinetics.com/support/ies. eW Blast Powercore 2700 K, 10° Clear Lens Lumens 1990 Efficacy 42.3 Polar Candela Distribution 90º Cd: 0 11,333 80º 22,667 70º 34,000 60º 45,333 56,667 50º Illuminance at Distance Candela Table 0 5 15 25 35 45 55 65 75 85 90 0.0 22.5 45.0 67.5 90.0 67192 67192 67192 67192 67192 21402 21540 21853 22041 22041 451 461 477 479 468 241 236 230 232 223 127 127 129 125 118 70 68 68 66 61 26 28 26 24 22 13 15 15 13 4 4 4 2 2 0 0 0 0 0 0 0 0 0 0 0 10º 20º - 0º H 30º 8 ft 12 ft 16 ft 20 ft Beam Width 4200 fc 0.6 ft 0.6 ft 1050 fc 1.1 ft 1.1 ft 467 fc 1.7 ft 1.7 ft 262 fc 2.2 ft 2.3 ft 168 fc 2.8 ft 2.8 ft 117 fc 3.4 ft 3.4 ft 259 ft (78.9 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 8.0º Horiz. Spread: 8.1º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 4 ft 24 ft 68,000 VA: 0º Center Beam fc LUMENS 1819 1900 1974 1990 0 1990 %FIXT 91.4 95.5 99.2 100.0 0.0 100.0 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 0 1 2 3 4 5 6 7 8 9 10 119119119119 116114112111 113110107105 110106103101 108103100 98 106101 98 95 104 99 96 93 102 97 94 92 100 96 92 90 99 94 91 89 98 93 90 88 116116116116 113112110109 111108106104 108105102100 106102 99 97 104100 97 95 103 98 95 93 101 97 94 91 100 95 92 90 98 94 91 89 97 93 90 88 111111111 108107106 105103102 103100 99 100 98 96 99 96 94 97 94 92 96 93 91 94 92 90 93 91 89 92 90 88 Effective Floor Cavity Reflectance: 20% 30 50 30 10 10 50 30 10 0 0 106106106 104103103 102101100 100 99 97 99 97 95 97 95 93 96 94 92 95 92 91 94 91 90 93 90 89 92 89 88 102102102 101100100 100 98 98 98 97 96 97 95 94 96 94 93 95 93 91 94 92 90 93 91 89 92 90 88 91 89 88 100 98 96 94 93 92 90 89 89 88 87 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio eW Blast Powercore 2700 K, 21º Frosted Lens Lumens 1786 Efficacy 38.2 Polar Candela Distribution Cd: 0 90º 1,300 80º 2,600 70º 3,900 60º 5,200 6,500 50º 0 5 15 25 35 45 55 65 75 85 90 Illuminance at Distance Candela Table 0.0 7791 6536 2038 585 245 126 70 38 15 0 0 22.5 7791 6552 2046 586 245 126 70 39 16 1 0 45.0 7791 6540 2054 589 246 127 71 41 18 2 0 67.5 7791 6544 2059 590 247 128 72 42 19 2 0 90.0 7791 6547 2063 592 247 128 72 42 20 3 0 10º - 0º H 20º 30º LUMENS 1403 1560 1724 1786 0 1786 12.0 ft 16.0 ft 20.0 ft Beam Width 487 fc 1.4 ft 1.4 ft 122 fc 2.9 ft 2.9 ft 54 fc 4.3 ft 4.3 ft 30 fc 5.7 ft 5.8 ft 19 fc 7.2 ft 7.2 ft 14 fc 8.6 ft 8.7 ft 88.3 ft (26.9 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 20.3º Horiz. Spread: 20.5º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Summary Zonal Lumen ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 8.0 ft 24.0 ft 7,800 VA: 0º Center Beam fc 4.0 ft %FIXT 78.6 87.4 96.5 100.0 0.0 100.0 Effective Floor Cavity Reflectance: 20% RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 50 30 10 119119119119 114111109107 109104100 97 104 98 94 90 100 93 88 84 96 88 83 80 92 84 79 76 89 81 76 72 86 78 73 69 83 75 70 67 80 72 68 64 70 70 50 30 10 116116116116 111109107105 107103 99 96 102 97 93 89 98 92 87 84 94 88 83 79 91 84 79 75 88 80 75 72 85 77 72 69 82 74 70 67 80 72 67 64 50 50 30 10 111111111 105103102 99 97 94 94 91 88 90 86 83 86 82 79 82 78 75 79 75 72 76 72 69 74 69 66 71 67 64 30 50 30 10 106106106 101100 99 96 94 92 92 89 87 88 85 82 84 81 78 81 77 74 78 74 71 75 71 69 73 69 66 71 67 64 10 50 30 10 102102102 98 97 96 94 92 90 90 87 85 86 83 81 83 80 77 80 76 74 77 74 71 74 71 68 72 68 66 70 66 64 0 0 100 94 89 84 80 76 73 70 67 65 63 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 4 eW Blast Powercore Product Guide eW Blast Powercore 2700 K, 36° Frosted Lens Lumens 1613 Efficacy 32.5 Polar Candela Distribution 90º Cd: 0 500 80º 1,000 70º 1,500 60º 2,000 2,500 50º Illuminance at Distance Candela Table 0 5 15 25 35 45 55 65 75 85 90 0.0 2930 2786 1784 810 340 159 83 44 18 2 0 22.5 2930 2787 1784 808 340 159 83 45 19 3 0 45.0 2930 2784 1783 809 341 160 84 46 20 3 0 67.5 2930 2781 1783 810 343 161 85 47 21 3 0 90.0 2930 2782 1785 812 344 162 86 47 21 4 0 10º 20º - 0º H 30º 8 ft 12 ft 16 ft 20 ft LUMENS 1119 1339 1542 1613 0 1613 Beam Width 183 fc 2.6 ft 2.6 ft 46 fc 5.1 ft 5.1 ft 20 fc 7.7 ft 7.7 ft 11 fc 10.3 ft 10.3 ft 7 fc 12.8 ft 12.9 ft 5 fc 15.4 ft 15.4 ft 54 ft (16.5 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 35.6º Horiz. Spread: 35.7º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 4 ft 24 ft 3,000 VA: 0º Center Beam fc Effective Floor Cavity Reflectance: 20% %FIXT 69.4 83.0 95.6 100.0 0.0 100.0 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 119119119119 113110107105 107102 98 94 101 95 89 85 96 88 83 78 91 83 77 72 87 78 72 67 83 74 68 63 79 70 64 60 76 66 60 56 73 63 57 54 116116116116 111108105103 105100 96 93 99 93 88 85 94 87 82 78 90 82 76 72 86 77 71 67 82 73 67 63 78 69 63 59 75 66 60 56 72 63 57 53 111111111 104102100 97 94 91 91 86 83 85 80 77 80 75 71 76 71 67 72 67 63 68 63 59 65 60 56 62 57 53 106106106 100 99 97 94 91 89 88 85 82 83 79 76 78 74 71 74 70 66 70 66 62 67 62 59 64 59 56 61 56 53 102102102 97 95 94 91 89 87 86 83 81 81 78 75 77 73 70 73 69 66 69 65 62 66 62 59 63 59 56 60 56 53 0 0 100 92 85 79 73 69 64 61 57 54 52 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio eW Blast Powercore 2700 K, 83º No Optic Lumens 1969 Efficacy 40.2 Polar Candela Distribution 90º Cd: 0 0 5 200 80º 15 400 25 70º 35 45 55 60º 65 75 85 50º 90 600 800 1,000 Illuminance at Distance Candela Table 0.0 1159 1147 1048 912 750 395 181 55 16 9 0 22.5 1159 1148 1051 912 747 432 181 70 19 9 0 45.0 1159 1146 1049 906 746 564 173 68 24 7 0 67.5 1159 1144 1043 905 743 533 241 89 32 6 0 90.0 1159 1146 1041 907 744 519 242 87 37 10 0 10º - 0º H 20º 30º LUMENS 820 1284 1855 1969 0 1969 12 ft 16 ft 20 ft Beam Width 72 fc 6.6 ft 7.4 ft 18 fc 13.2 ft 14.8 ft 8 fc 19.8 ft 22.1 ft 5 fc 26.4 ft 29.5 ft 3 fc 33.0 ft 36.9 ft 2 fc 39.6 ft 44.3 ft 34 ft (10.4 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 79.1º Horiz. Spread: 85.3º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 8 ft 24 ft 1,200 VA: 0º Center Beam fc 4 ft %FIXT 41.7 65.2 94.2 100.0 0.0 100.0 Effective Floor Cavity Reflectance: 20% RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 119119119119 112108105102 104 97 92 88 97 88 82 76 90 80 73 67 84 73 65 60 78 67 59 53 73 61 54 48 68 56 49 44 64 52 45 40 60 49 41 37 116116116116 109106103100 101 96 91 87 94 87 81 76 88 79 72 67 82 72 65 59 76 66 59 53 71 60 53 48 67 56 49 44 63 52 45 40 59 48 41 37 111111111 102 99 97 92 88 85 84 79 74 76 71 66 70 64 59 64 58 53 59 52 48 55 48 43 51 44 40 47 41 36 106106106 98 96 94 89 86 83 81 77 73 74 69 65 68 63 58 62 57 52 58 52 47 53 47 43 50 44 40 46 40 36 102102102 94 93 91 86 84 81 79 75 72 72 68 64 66 62 58 61 56 52 56 51 47 52 47 43 49 43 39 45 40 36 0 0 100 89 79 70 62 56 50 45 41 38 35 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 eW Blast Powercore Product Guide 5 eW Blast Powercore 4000 K, 10° Clear Lens Lumens 2390 Efficacy 45.9 Polar Candela Distribution 90º Cd: 0 13,333 80º 26,667 70º 40,000 60º 53,333 66,667 Illuminance at Distance Candela Table 0 5 15 25 35 45 55 65 75 85 90 0.0 22.5 45.0 67.5 90.0 79225 79225 79225 79225 79225 25903 26081 26325 26670 26650 520 536 577 581 577 276 276 272 276 268 146 150 150 150 146 73 73 77 81 73 24 20 33 28 33 0 12 12 12 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 50º 10º 20º - 0º H 30º LUMENS 2200 2297 2380 2390 0 2390 8.0 ft 12.0 ft 16.0 ft 20.0 ft Beam Width 4952 fc 0.6 ft 0.6 ft 1238 fc 1.1 ft 1.1 ft 550 fc 1.7 ft 1.7 ft 309 fc 2.3 ft 2.3 ft 198 fc 2.8 ft 2.9 ft 138 fc 3.4 ft 3.4 ft 281 ft (85.6 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 8.1º Horiz. Spread: 8.2º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 4.0 ft 24.0 ft 80,000 VA: 0º Center Beam fc %FIXT 92.0 96.1 99.6 100.0 0.0 100.0 RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 50 30 10 119119119119 116114112111 113110107105 110107104101 108104101 98 106101 98 96 104 99 96 94 102 98 94 92 101 96 93 91 100 95 92 90 98 94 91 89 70 70 50 30 10 116116116116 114112111109 111108106104 109105103101 107103100 98 105101 98 95 103 99 96 94 102 97 94 92 100 96 93 91 99 94 92 90 98 93 91 89 50 50 30 10 111111111 108107106 105104102 103101 99 101 98 97 99 97 95 97 95 93 96 94 92 95 92 91 94 91 90 93 90 89 Effective Floor Cavity Reflectance: 20% 30 50 30 10 106106106 104104103 102101100 101 99 98 99 97 96 98 96 94 96 94 92 95 93 91 94 92 90 93 91 89 92 90 88 10 50 30 10 102102102 101100100 100 99 98 99 97 96 97 96 95 96 95 93 95 93 92 94 92 91 93 91 90 92 90 89 92 90 88 0 0 100 98 97 95 93 92 91 90 89 88 88 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio eW Blast Powercore 4000 K, 21º Frosted Lens Lumens 2141 Efficacy 50.9 Polar Candela Distribution Cd: 0 90º 1,583 80º 3,167 70º 4,750 60º 6,333 7,917 50º 0 5 15 25 35 45 55 65 75 85 90 Illuminance at Distance Candela Table 0.0 9399 7861 2474 708 292 147 82 45 17 0 0 22.5 9399 7872 2479 709 292 147 82 45 17 0 0 45.0 9399 7858 2483 710 292 147 83 47 21 2 0 67.5 9399 7857 2485 711 293 149 85 47 21 1 0 90.0 9399 7860 2490 712 293 149 85 49 21 2 0 10º - 0º H 20º 30º LUMENS 1692 1880 2071 2141 0 2141 12.0 ft 16.0 ft 20.0 ft Beam Width 587 fc 1.4 ft 1.4 ft 147 fc 2.9 ft 2.9 ft 65 fc 4.3 ft 4.3 ft 37 fc 5.7 ft 5.8 ft 24 fc 7.2 ft 7.2 ft 16 fc 8.6 ft 8.6 ft 97 ft (30 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 20.3º Horiz. Spread: 20.4º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 8.0 ft 24.0 ft 9,500 VA: 0º Center Beam fc 4.0 ft %FIXT 79.0 87.8 96.7 100.0 0.0 100.0 RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 50 30 10 119119119119 114111109107 109104101 98 104 98 94 90 100 93 88 85 96 89 84 80 92 85 80 76 89 81 76 73 86 78 73 70 83 75 70 67 81 73 68 65 70 70 50 30 10 116116116116 111109107105 107103 99 96 102 97 93 90 98 92 88 84 95 88 83 80 91 84 79 76 88 81 76 72 85 78 73 69 82 75 70 67 80 72 68 65 50 50 30 10 111111111 105103102 99 97 94 94 91 88 90 86 83 86 82 79 83 78 75 79 75 72 77 72 69 74 70 67 71 67 64 Effective Floor Cavity Reflectance: 20% 30 50 30 10 106106106 101100 99 97 94 92 92 89 87 88 85 82 85 81 78 81 78 75 78 74 72 76 72 69 73 69 66 71 67 64 10 50 30 10 102102102 98 97 96 94 92 90 90 88 86 86 84 81 83 80 77 80 77 74 77 74 71 75 71 69 72 69 66 70 67 64 0 0 100 94 89 84 80 76 73 70 67 65 63 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 6 eW Blast Powercore Product Guide eW Blast Powercore 4000 K, 36° Frosted Lens Lumens 1868 Efficacy 41.9 Polar Candela Distribution 90º Cd: 0 567 80º 1,133 70º 1,700 60º 2,267 2,833 50º Illuminance at Distance Candela Table 0 5 15 25 35 45 55 65 75 85 90 0.0 3352 3189 2047 937 397 187 99 53 22 2 0 22.5 3352 3190 2048 934 396 187 100 54 22 2 0 45.0 3352 3186 2048 935 397 188 101 55 25 3 0 67.5 3352 3182 2045 936 399 189 101 56 26 4 0 90.0 3352 3184 2049 935 399 190 102 57 26 4 0 10º 20º - 0º H 30º 4 ft 8 ft 12 ft 16 ft 20 ft 24 ft 3,400 VA: 0º Center Beam fc 2.6 ft 5.2 ft 5.2 ft 23 fc 7.7 ft 7.7 ft 13 fc 10.3 ft 10.3 ft 8 fc 12.9 ft 12.9 ft 6 fc 15.5 ft 15.5 ft Vert. Spread: 35.8º Horiz. Spread: 35.8º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary LUMENS 1287 1542 1782 1868 0 1868 2.6 ft 52 fc 58 ft (17.7 m) 1 fc maximum distance 40º - 90º H ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 Beam Width 210 fc Effective Floor Cavity Reflectance: 20% %FIXT 68.9 82.6 95.4 100.0 0.0 100.0 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 119119119119 113110107105 107102 97 94 101 94 89 85 96 88 82 78 91 83 77 72 87 78 72 67 83 73 67 63 79 69 63 59 76 66 60 56 72 63 57 53 116116116116 110108105103 105100 96 93 99 93 88 84 94 87 82 77 90 82 76 72 85 77 71 67 81 73 67 63 78 69 63 59 74 65 60 56 71 62 57 53 111111111 104102100 97 93 91 90 86 83 85 80 77 80 75 71 75 70 66 71 66 62 68 63 59 65 59 56 62 56 53 106106106 100 98 97 94 91 89 88 84 82 83 79 76 78 74 70 74 69 66 70 66 62 67 62 59 64 59 56 61 56 53 102102102 97 95 94 91 89 87 86 83 80 81 78 75 77 73 70 73 69 66 69 65 62 66 62 58 63 59 55 60 56 53 0 0 100 92 85 79 73 68 64 60 57 54 51 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio eW Blast Powercore 4000 K, 83º No Optic Polar Candela Distribution 90º Cd: 0 233 Lumens 2398 Efficacy 49.2 0 5 80º 15 467 70º 700 60º 933 1,167 50º 25 35 45 55 65 75 85 90 Illuminance at Distance Candela Table 0.0 1377 1365 1252 1098 916 488 237 63 19 11 0 22.5 1377 1367 1256 1099 914 511 235 76 22 10 0 45.0 1377 1364 1255 1092 914 704 223 74 30 9 0 67.5 1377 1361 1246 1091 910 669 307 98 42 7 0 90.0 1377 1363 1244 1091 911 645 307 94 50 12 0 10º - 0º H 20º 30º LUMENS 984 1552 2267 2398 0 2398 12 ft 16 ft 20 ft Beam Width 86 fc 6.7 ft 7.6 ft 22 fc 13.4 ft 15.3 ft 10 fc 20.1 ft 22.9 ft 5 fc 26.8 ft 30.6 ft 3 fc 33.5 ft 38.2 ft 2 fc 40.2 ft 45.8 ft 37.2 ft (11.3 m) 1 fc maximum distance 40º - 90º H Vert. Spread: 80.0º Horiz. Spread: 87.3º Coefficients Of Utilization - Zonal Cavity Method Zonal Lumen Zonal Lumen Summary ZONE 0- 30 0- 40 0- 60 0- 90 90-180 0-180 8 ft 24 ft 1,400 VA: 0º Center Beam fc 4 ft %FIXT 41.0 64.7 94.5 100.0 0.0 100.0 Effective Floor Cavity Reflectance: 20% RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 119119119119 112108105102 104 97 92 88 96 88 81 76 90 80 73 67 83 73 65 60 78 66 59 53 73 61 53 48 68 56 49 43 64 52 45 40 60 48 41 36 116116116116 109106103100 101 96 91 87 94 87 80 76 88 79 72 67 82 72 65 59 76 66 58 53 71 60 53 48 67 55 48 43 63 51 44 40 59 48 41 36 111111111 102 99 97 92 88 85 84 79 74 76 70 66 70 63 59 64 57 53 59 52 48 54 48 43 50 44 39 47 41 36 106106106 98 96 94 89 86 83 81 77 73 74 69 65 68 62 58 62 57 52 57 52 47 53 47 43 49 43 39 46 40 36 102102102 94 93 91 86 83 81 79 75 72 72 68 64 66 61 57 61 56 52 56 51 47 52 47 43 48 43 39 45 40 36 0 0 100 89 79 70 62 56 50 45 41 37 34 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 eW Blast Powercore Product Guide 7 eW Blast Powercore Specifications Due to continuous improvements and innovations, specifications may change without notice. Item Lumens† Efficacy (lm / W) CRI Item Output 10° 21° 36° 83° 2700 K 1990 1786 1613 1969 4000 K 2390 2141 1868 2398 10º Beam Angle 2700 K 42.3 38.2 32.5 40.2 4000 K 45.9 50.9 41.9 49.2 2700 K 83 83 83 83 4000 K 82 82 82 82 Specification 2700 K* Beam Angle 10° / 21°/ 36° / 83° (no optic) Mixing Distance 6 in (152 mm) to uniform light 10º Beam Angle 21º Beam Angle 70,000 hours L70 @ 25° C 37,000 hours L70 @ 50° C 90,000 hours L50 @ 25° C 68,000 hours L50 @ 50° C Lumen Maintenance‡ Electrical Control Physical Certification and Safety 110º Color Temperature* 110º 4000 K* 110º 100 / 120 / 240 / 277 VAC, auto-switching, 50 / 60 Hz Power Consumption 50 W maximum at full output, steady state 110º Rotation Power Factor .98 @ 120 VAC Dimming Compatible with selected commercially available reversephase ELV-type dimmers§ Dimensions (Height x Width x Depth) 7.1 x 12.5 x 4.9 in (180 x 318 x 124 mm) Weight 6.4 lb (2.9 kg) Housing Die-cast aluminium, white or black powder-coated finish Lens Clear tempered glass (10° and 83° beam angles) Frosted tempered glass (21° and 36° beam angles) Fixture Connections 6 ft (1.8 m) unified power / data cable Temperature Ranges -40° – 122° F (-40° – 50° C) Operating -4° – 122° F (-20° – 50° C) Startup -40° – 176° F (-40° – 80° C) Storage Fixture Run Lengths To calculate fixture run lengths and total power consumption for your specific installation, download the Configuration Calculator from www.philipscolorkinetics.com/support/ install_tool/ 0 – 95%, non-condensing Certification UL / cUL, FCC Class B, CE Environment Dry / Damp / Wet Location, IP66 10º 36ºBeam BeamAngle Angle 21º Beam Angle 110º Rotation Input Voltage Humidity 110º 110º 110º * Correlated color temperature (CCT) complies with ANSI C78.377-2008 for the chromaticicty of solid state lighting products. † Lumen measurement complies with IES LM-79-08 testing procedures. ‡ L70 = 70% lumen maintenance (when light output drops below 70% of initial output). L 50 = 50% lumen maintenance (when light output drops below 50% of initial output). Ambient luminaire temperatures specified. Lumen maintenance calculations are based on lifetime prediction graphs supplied by LED source manufacturers. Calculations for white-light LED fixtures are based on measurements that comply with IES LM-80-08 testing procedures. Refer to www.philipscolorkinetics.com/support/appnotes/ for more information. 110º Rotatio 110º 110º 83º Beam Angle 36º Beam Angle 12.5 in 318 mm 6.5 in 165 mm 0.65 in 17 mm 4.75 in 121 mm 1.35 in 34 mm 7.1 in 180 mm 4.9 in 124 mm § Refer to www.philipscolorkinetics.com/support/appnotes/ for more information. 6.5 in 165 mm 3.9 in 99 mm 7.25 in 184 mm 8 eW Blast Powercore Product Guide Fixtures Included in the box Item Housing Color eW Blast Powercore fixture (2) 8-32 screws for indoor installation (4) 10-24 stainless steel screws for outdoor installation 1/8 in hex key wrench for fixture positioning and locking Junction box gasket Installation Instructions White eW Blast Powercore 2700 K UL / cUL Black White eW Blast Powercore 4000 K UL / cUL Black White eW Blast Powercore 2700 K CE / CQC Black White eW Blast Powercore 4000 K CE / CQC Black Lens Item Number Philips 12NC 10° (clear lens) 523-000069-00 910503702322 21° (frosted lens) 523-000069-02 910503702365 36° (frosted lens) 523-000069-04 910503702367 83° (no optic) 523-000069-06 910503702369 10° (clear lens) 523-000069-01 910503702364 21° (frosted lens) 523-000069-03 910503702366 36° (frosted lens) 523-000069-05 910503702368 83° (no optic) 523-000069-07 910503702370 10° (clear lens) 523-000069-08 910503702371 21° (frosted lens) 523-000069-10 910503702373 36° (frosted lens) 523-000069-12 910503702375 83° (no optic) 523-000069-14 910503702377 10° (clear lens) 523-000069-09 910503702372 21° (frosted lens) 523-000069-11 910503702374 36° (frosted lens) 523-000069-13 910503702376 83° (no optic) 523-000069-15 910503702378 10° (clear lens) 523-000069-16 910503702379 21° (frosted lens) 523-000069-18 910503702381 36° (frosted lens) 523-000069-20 910503702383 83° (no optic) 523-000069-22 910503702385 10° (clear lens) 523-000069-17 910503702380 21° (frosted lens) 523-000069-19 910503702382 36° (frosted lens) 523-000069-21 910503702384 83° (no optic) 523-000069-23 910503702386 10° (clear lens) 523-000069-24 910503702387 21° (frosted lens) 523-000069-26 910503702389 36° (frosted lens) 523-000069-28 910503702391 83° (no optic) 523-000069-30 910503702393 10° (clear lens) 523-000069-25 910503702388 21° (frosted lens) 523-000069-27 910503702390 36° (frosted lens) 523-000069-29 910503702392 83° (no optic) 523-000069-31 910503702394 Use Item Number when ordering in North America. eW Blast Powercore Product Guide 9 Accessories Designed specifically for the family of Blast fixtures, accessories provide additional options for controlling and dispersing light. Accessory holders snap to the front of the fixture and are required for mounting accessories. Accessory holders prevent accessories from falling out if the fixture is tipped or hung upside down. Item Housing Color Item Number Philips 12NC White 120-000070-00 910503702864 Black 120-000070-01 910503702863 White 120-000005-03 910503702847 Black 120-000005-04 910503702848 White 120-000009-03 910503702843 Black 120-000009-04 910503702844 White 120-000015-03 910503702851 Black 120-000015-04 910503702852 White 120-000019-03 910503702855 Black 120-000019-04 910503702856 Horizontal Glass Spread Lens* 36° (ribs out) / 50° (ribs in) 120-000025-00 910503703897 Horizontal / Vertical Glass Spread Lens* 40° 120-000025-01 910503703898 Accessory Holders Top Hats Half Top Hats Egg Crate Louvers Barndoors * Intended for use with Blast fixtures with 10° clear lens 10 eW Blast Powercore Product Guide Use Item Number when ordering in North America. Installation eW Blast Powercore is an LED wash light providing high-intensity white light while consuming less energy than comparable non-LED fixtures. Powercore, which delivers line voltage directly to the fixture, eases installation by eliminating the need for external power supplies or special wiring. E Refer to the eW Blast Powercore Installation Instructions for specific warning and caution statements. Owner/User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate eW Blast Powercore fixtures in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance. Installing in Damp or Wet Locations When installing in damp or wet locations, it is good practice to seal all fixtures and junction boxes with electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in any wiring compartments, cables, or other electrical parts. You must use suitable outdoor-rated junction boxes when installing in damp or wet locations. Additionally, you must use gaskets, clamps, and other parts required for installation to comply with all applicable local and national codes. Assemble Additional Parts and Tools Make sure all additional parts and tools are available, including: Included in the box eW Blast Powercore fixture (2) 8-32 screws for indoor installation (4) 10-24 stainless steel screws for outdoor installation 1/8 in hex key wrench for fixture positioning and locking Junction box gasket Installation Instructions • The provided 8-32 screws for indoor installations, or the 10-24 stainless steel screws for outdoor installations • The provided 1/8 in hex key wrench • One 4 in (102 mm) round US electrical junction box per fixture, rated for your application, with 3.5 in (89 mm) center-to-center screw holes for attaching the fixture’s base. (Refer to the manufacturer’s literature for additional items required for mounting or sealing.) • The provided junction box gasket • A sufficient length of 3-conductor copper wire • Conduit as required • Electronics-grade room temperature vulcanizing (RTV) silicone sealant as required Install the Fixtures eW Blast Powercore fixtures can be installed in series or in parallel (wired to a common junction box). Each fixture requires a dedicated junction box for mounting. Ensure that all junction boxes are suitable for the environment and that all wiring between junction boxes complies with local codes. eW Blast Powercore fixtures can be controlled either with a standard wall switch (on / off) or a commercially available reverse-phase ELV-type dimmer. Refer to the installation instructions included with the wall of dimmer switch for installing and wiring information. eW Blast Powercore Product Guide 11 Make sure the power is OFF before mounting and connecting fixtures. E In locations where US junction boxes are not available, you can mount fixtures directly to a wall or other mounting surface. For help with your specific installation, consult your local support organization, or contact Application Engineering Services at support@colorkinetics.com. 1. Install junction boxes. (Refer to the manufacturer’s literature for additional items required for mounting or sealing.) 2. If installing fixtures in a series, pull 3-conductor copper wire between the junction boxes. If installing fixtures in parallel, pull 3-conductor copper wire from a common junction box, and from the common junction box to each fixture’s junction box. E When installing eW Blast Powercore fixtures, the input earth ground, canopy earth ground, and fixture cable earth ground must all be connected together. 3. Trim the cable from the fixture to fit in the junction box, leaving enough cable to make wiring connections. 4. Insert the fixture cable through the provided junction box gasket before making wire connections. When attaching the fixture to the junction box, ensure that the gasket is compressed evenly. 5. For UL / cUL installations, use wire nuts to connect line (black), neutral (white), and ground (green). For CE / CQC installations, use wire nuts to connect line (brown), neutral (blue), and ground (green / yellow). ~~ ~~ ULUL / cUL / cUL CE CE / CQC / CQC Fixture cable dimensions .38 in (9.6 mm) 18 AWG .04 in (1 mm) 6. Tuck wire connections into the junction box, and use the provided screws to attach the fixture to the junction box. 7. If installing in a wet or damp location, seal all junction boxes with electronicsgrade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes. 8. If installing in parallel, connect the wires from each fixture to the lead wire from the line power source in the common junction box. E Wiring between junction boxes must comply with local codes. 9. Connect the wire from the first fixture in the series to the line power source if installing in series, or from the common junction box to the line power source if installing in parallel. Line V RT e ilicon S RTV voltage e on lic Si RTV Silicone Line voltage Line voltage 12 eW Blast Powercore Product Guide V RT ne ico Sil Attach Safety Cable Safety cable minimum requirements Material 316 Stainless Steel Size 5/64 to 3/16 in (2.0 to 4.8 mm) nominal diameter. Minimum break load must be greater than 400 lb (181 kg) Construction 7 x 7 (49 wires) preformed stranded Make sure the power is ON before aiming and locking the fixtures. Using the provided 1/8 in hex key wrench, loosen the rotation and tilting set screws. Aim the fixtures by rotating the base and tilting the beam as desired. Tighten the two pairs of set screws to lock the fixture in place. E For exterior applications with direct exposure to water, eW Blast Powercore fixtures should not be aimed directly upwards, as water may pool on the lens and affect beam quality. Instead, the fixture should be angled to allow for proper water drainage. 110° 110º m Angle Angle Each eW Blast Powercore fixture is designed for use with a safety cable to tether the fixture to a secure anchor point. When dictated by local or state code or advised by a structural engineer, attach a safety cable to the bracket located on the back of the fixture. Remove the two screws that attach the cable bracket, loop the safety cable over the cable bracket, and reattach to the fixture. Attach the safety cable to the mounting surface using a method that follows the code or engineer’s requirements. Aim and Lock the Fixtures E Do not look directly into the fixture when aiming and locking. 110º 0º (Optional) 21º Beam Angle 110º 110º 110º 110º 10º 36ºBeam BeamAngle Angle 83ºBeam BeamAngle Angle 21º 110º 36º Beam Angle 110º 83º Beam Angle 1/8 in 350° 110º Rotation 110º Rotation 110º 36º Beam Angle 110º 83º Beam Angle eW Blast Powercore Product Guide 13 14 eW Blast Powercore Product Guide eW Blast Powercore Product Guide 15 Philips Color Kinetics 3 Burlington Woods Drive Burlington, Massachusetts 01803 USA Tel 888.385.5742 Tel 617.423.9999 Fax 617.423.9998 www.philipscolorkinetics.com Copyright © 2008 – 2012 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, eW Fuse, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations. specifications may change without notice. Cover Photo: John Brandon Miller Photography DAS-000024-00 R09 08-12