VISUAL SIGNALS AdaptaBeacon® Explosionproof Strobe Diode Polarized, NEMA Type 3R & 4X, UL 1971 Listed 116DEXSTC-FJ Series www.leedan.com FEATURES > Bracket, ceiling, pendant or stanchion mount > Diode polarized for use in electronically supervised circuits > High impact glass dome > 65 flashes per minute > For use in fire alarm systems > Factory sealed - no external seals required > Quick connect - threads onto mounting module for easy installation > Shock absorbing receptacle > Easy to assemble & relamp > Gaskets seal out dirt & moisture > Epoxy powder coat for corrosion resistance AGENCY APPROVALS > UL 1971 Listed for indoor visual signaling for the hearing impaired in non-sleeping areas > NEMA Type 3R & Type 4X Rated > Rated at 60 candela (wall) and 60 candela (ceiling) per UL 1971 info@leedan.com Toll-Free: 800-231-1414 Edwards Explosionproof AdaptaBeacon Strobe Lights are designed for installation in hazardous location environments. Rigid specifications and state-of-the-art technology provide for high visual output and low maintenance. Powder coat epoxy finished gray. Each explosionproof strobe is UL Listed for Type 3R and Type 4X installations. The units contain a supervisory diode and four wire leads, for use in fire alarm applications. This strobe, when pendant, wall or ceiling mounted, is also UL 1971 Listed (ADA) for indoor visual signaling applications for the hearing impaired in non-sleeping areas. Stanchion mounted models are UL 1638 Listed for Private Mode Emergency Signaling. The Edwards 116DEXSTC-FJ Hazardous Location Supervised AdaptaBeacon Strobe Light is designed for use in compatible fire alarm systems and other applications requiring electrical supervision of signaling circuit field wiring. FAMILY TREE Stanchion 116EX-S Pendant 116EX-P 1 3/4" Hub 3/4" Conduit Entry Ceiling/Wall 116EX-C 1 3/4" Hubs (3) 3/4" Conduit Entries Ceiling/Wall 116EX-C Wall Bracket Elbow 116EX-B 1 3/4" Hub D-04A > UL Listed Class I, Div. 1 & 2 3-XX 116DEXSTC-FJ 41 Woodford Avenue | Ph: 800.336.4206 | Plainville, CT 06062 Fx: 800.454.2363 www.edwards-signals.com © Copyright 2006 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6 3/4" 4" 13 1/4" Stanchion Mount Ceiling Mount 4" 1 1/4" 12 3/4" 1" 13 1/2" 1 1/4" conduit 13" 13 3/4" 25 deg. 12 9/16" 9 7/16" Wall Mount 1" 6 3/4" 4" 7 1/4" Pendant Mount 4" 16 1/16" 12" 5/16" 12 3/4" MOUNTING MODULES Cat. No. Description 116EX-B Wall bracket mounting elbow 116EX-C Ceiling/wall mounting module 116EX-P Pendant mounting module 116EX-S Stanchion mounting module 16 13/16" Lens Color Clear Cat. No. 116DEXSTC-FJ Electrical Rating 24V DC FWR 0.774 Amp (Max DC) 1.14 Amp (Max FWR)** Replacement Dome 116-Globe 7 1/4" Optional Dome Guard 116-GRD Replacement Strobe Tube 92-ST 3,000 hr* Peak Candlepower 800,000 *Calculated at operating power to 75% efficiency. **Replacement Circuit 116EXSTC-FJ-SA HAZARDOUS LOCATION LISTINGS Operating Temperature Class I, Div. 1 & 2 Class II & III, Div. 1 Groups C, D Groups E, F, G Ambient Temp. Supply Wire Temp. Marking Class I, Div. 2 Groups A, B 40°C 75°C T2D (215°C) T6 (85°C) T4A (120°C) T4A (120 °C) 55°C 90°C T2C (230°C) T6 (85°C) T4 (135°C) T4 (135 °C) Toll-Free: 800-231-1414 41 Woodford Avenue | Ph: 800.336.4206 | Plainville, CT 06062 Fx: 800.454.2363 www.edwards-signals.com 3-XX © Copyright 200 6 Edwards info@leedan.com D-04A www.leedan.com Class II & III, Div. 2 Group F, G