GE Security EST Fire & Life Safety Notification Appliances Overview Standard Features 116DEXSTC-FJ hazardous location strobes are in-rush current limited life safety signaling appliances designed for installation in hazardous environments. Rigid specifications and state-of-the-art technology provide for high visual output and low maintenance. • UL 1971 listed and ADA compliant for the hearing impaired When pendant, wall or ceiling mounted, the 116DEXSTC-FJ meets or exceeds the requirements of UL 1971 Signaling Appliance for the Hearing Impaired. Stanchion mount models are UL 1638 Listed for private mode emergency signaling. All models are CSFM Listed. • Stanchion mount available for private mode signaling The 116DEXSTC-FJ is intended for indoor use in UL listed compatible fire alarm systems and other applications requiring electrical supervision of signaling circuit field wiring. Its strobe flashes a 360-degree beam of light approximately 65 times per minute with a UL 1971 60 cd wall and ceiling light output. In Canada, the 116DEXSTC-FJ is listed to ULC-S526-02 Visible Signal Device for Fire Alarm Systems, suitable for indoor and outdoor applications. • 65 flashes per minute When assembled with an available mounting option, the 116DEXSTC-FJ is UL Listed for use in Class I, Division 1, Groups C and D, Class I, Division 2, Groups A, B, C and D, Class II Division 1, Group E, F and G, Class II, Division 2, Group F and G, and Class III Division 1 and 2 hazardous locations. This strobe is UL and cUL Listed as a Type 3R and 4X enclosure. Hazardous Location Strobes 116DEXSTC-FJ • Approved for fire alarm applications • Bracket, ceiling or pendant mount • Diode polarized for use in electronically supervised circuits • High impact glass dome • Factory sealed - no external seals required • Quick connect - threads onto mounting module for easy installation • Shock absorbing receptacle • Easy to assemble and relamp • Epoxy powder coat for corrosion resistance • ULC-S526-02 listed for indoor and outdoor applications Wall Mount Pendant Mount Stanchion mount option also available. Ceiling Mount 360-degree field of view. Data Sheet 85001-0586 Issue 1 Not to be used for installation purposes. Page of 6 7 1/4" 7 1/4" Application Assembly 116DEXSTC-FJ hazardous location strobes are designed for use in compatible GE Security fire alarm systems and other applications requiring electrical supervision of signaling circuit field wiring. 116DEXSTC-FJ signals come pre-assembled, but come apart easily for cleaning and relamping. These strobes are suitable for many locations including mines, granaries, flour mills, tankers, refineries, laboratories and other applica12 9/16" tions where environmental 116DEXSTC-FJ 9 7/16" hazards may be present. 6 3/4" strobes are particularly well-suited 1"in areas of high noise levels 4" where standard bells or horns are not satisfactory. They are suitable for indoor or outdoor applications, however, the UL 1971 rating is for indoor applications only. 4" Set Screw 13 1/4" 1 1/4" Set Screw 12 3/4" Strobe13Tube 1/2" When pendant, wall, or ceiling mounted, 116DEXSTC-FJ strobes are ULC-S526-02 listed for indoor and outdoor applications and UL 16 1/16" 5/16" 1971 Listed (ADA compliant) for indoor visual signaling applications 16 13/16" in non-sleeping areas. Stanchion mounted strobes are UL 1638 listed for private mode emergency Set Screws signaling only. Stanchion mounting is not ULC-S526-02 listed as a visible signal device for fire alarm systems. 1 1/4" Conduit Globe & Guard Assembly 25° Wiring KEY: Light symbol - (-) (+) White From Power Source or Previous Signaling Device (+) White Series 116DEX (+) White Wire nut symbol - (+) White End-of-Line Resistor, when required with supervised system Series 116DEX Black (-) Black (-) Black (-) Black (-) (+) For non-fire alarm use, i.e. without field wire supervision, installer can tie the two white leads together and tie the two black leads together Notes: 1. DC Polarity of circuit shown in supervisory state (signal inactive). Circuit polarity to reverse to activate signal 2. Electrical supervision requires wire run to be broken at each device. 3. Device for constant input voltage. Do not connect to “coded” or pulsating voltage. 4. For non-fire alarm use, i.e.: without field wire supervision, the installer can tie the two white leads together and tie the two black leads together. Hazardous Location Listings Ambient Temperature 40 °C 55 °C 66 °C Supply Wire Temperature Marking 75 °C 90 °C 105 °C Operating Temperature Class I, Div. 2 Class I, Div. 1 & 2 Groups A, B Groups C, D T2D (215 °C) T6 (85 °C) T2C (230 °C) T6 (85 °C) T2C (230 °C) T6(85 °C) Class II, Div. 1 Groups E, F, G, & Class III T4A (120 °C) T4 (135 °C) T3C (160 °C) Class II, Div. 2 Groups F, G, & Class III T4A (120 °C) T4 (135 °C) T3C (160 °C) Data Sheet 85001-0586 Issue 1 Not to be used for installation purposes. Page of 6 Mounting Thanks to its modular design, the 116DEXSTC-FJ configures for pendant, ceiling, wall, or stanchion mounting. See the ordering information table for available mounting modules. STANCHION 116EX-S PENDANT 116EX-P 3/4" CONDUIT ENTRY CEILING 116EX-C 3/4" CONDUIT ENTRIES 116EX-C (WALL MOUNTED) 3/4" CONDUIT ENTRIES WALL 116EX-B 3" HUB Note: Stanchion mounting option is not listed to UL 1971 or ULC-S526-02. 116 SERIES HOUSING AND GLOBE ASSEMBLY WITH GUARD 1 1/4"CONDUIT ENTRY 6 3/4" Set Screw(s) 4" 4" 12" 5/16" 12 3/4" Set Screw 1" 13" 13 3/4" 7 1/4" 7 1/4" Ceiling Mount Pendant Mount Set Screw 13 1/4" 12 9/16" 9 7/16" 6 3/4" 1" 1 1/4" 4" Set Screw 4" 16 1/16" 12 3/4" 13 1/2" 5/16" 16 13/16" 1 1/4" Conduit Set Screws 25° Wall Mount Stancion Mount (for private mode signaling, not listed to UL UXWC and ULC-S526-02) KEY: Light symbol - (-) (+) White From Power Source or Series 116DEX (+) White (+) White Series 116DEX (+) White Data Sheet 85001-0586 Issue 1 Not to be used for installation purposes. Page of 6 Wire nut symbol - End-of-Line Resistor, when required with Light Output WALL BRACKET MOUNTING ANGLE (DEGREES) zero 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Compound 45 Effective Candela Light Output for Wall Bracket Mount Vertical Plane (Zero degree angle at side of globe) UL1971 REQUIRED DISPERSION AS % OF CD RATING VERTICAL HORIZONTAL PLANE PLANE 100% 100% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 75% 65% 75% 46% 75% 34% 75% 27% 55% 22% 45% 18% 40% 16% 35% 15% 35% 13% 30% 12% 30% 12% 25% 12% 25% -90 -85 130 -80 -75 -70 -65 120 -60 110 -55 -50 100 -45 90 -40 80 TYPICAL CD 70 -35 -30 UL REQUIRED CD FOR 110 RATING 60 -25 50 -20 40 -15 30 -10 20 24% -5 10 0 degrees 0 5 10 15 20 25 30 35 40 45 50 55 60 65 85 UL 1971 Hearing Impaired: 60 cd wall 145 135 110 140 155 120 150 165 160 175 170 180 170 165 160 155 150 130 135 140 140 130 130 100 UL REQUIRED CD FOR 110 RATING 110 60 110 125 TYPICAL CD 70 120 80 115 115 120 125 90 50 105 105 40 100 100 30 90 0 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 15 10 5 degrees 0 UL 1971 Hearing Impaired: 60 cd ceiling 20 25 30 35 40 45 50 55 60 65 70 75 80 85 10 95 20 95 100% 90% 90% 90% 90% 90% 75% 75% 75% 75% 55% 45% 40% 35% 35% 30% 30% 25% 25% 24% 145 Effective Candela Light Output for Ceiling Mount X & Y Planes (Zero degree angle at bottom of of globe) UL1971 REQUIRED X & Y PLANE DISPERSION AS % OF CD RATING 85 ANGLE (DEGREES) 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Compound 45 70 90 90 CEILING MOUNTING 80 75 Data Sheet 85001-0586 Issue 1 Not to be used for installation purposes. Page of 6 Specifications Mounting Pendant, ceiling, wall, or stanchion UL 1971(indoor) and ULC-S526-02 (indoor & Rated strobe intensity outoor): 60 cd Flash Rate 65 fps Agency Listings UL, ULC, CSFM UL Listed for Class I, Division 1 Groups C & D, UL Listed Hazardous Division 2, Groups A, B, C & D; Classifications Class II, Division 1, Groups E, F & G, Division 2, Groups F & G, and Class III Divisions 1 & 2 ADA Compliance UL 1971 listed signaling appliance for the (pendant, ceiling, and hearing impaired. Indoor, non-sleeping areas wall applications*) only. NEMA Ratings Type 3R, Type 4X, UL/ULC listed Voltage Range 16 - 33 Vdc 0.774 @ 24 Vdc (regulated) 1.140 @ 24 VFWR Operating Current (RMS) (regulated) UL: -31 to 150° F (-35° C to 65° C) Operating Temperature ULC: -40 to 150° F ( -40° C to 66° C) Lens Color Clear polycarbonate Strobe Type Xenon – clear/nominal white flash Finish Gray powder coat epoxy Weight 18 lbs (8.2 kg) * Stanchion mounted 116DEXSTC-FJ strobes are UL 1638 listed for private mode signaling. They are not listed to UL 1971 or ULC-S526-02. Ordering Information Model 116DEXSTC-FJ 116EX-B 116EX-C 116EX-P 116EX-S 116-GRD 116-GLOBE 92 -ST Description Ship Wt. Explosionproof Strobe, Diode Polarized 18 lbs 8.2 kg Wall bracket mounting elbow Ceiling/wall mounting module Pendant mounting module - ¾” (19 mm) NPT Stanchion mounting module - 1-1/4” (25 mm) NPT Lens Guard Replacement Globe Replacement Strobe Tube Data Sheet 85001-0586 Issue 1 Not to be used for installation purposes. Page of 6 GE Security U.S. T 888-378-2329 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Australia T 61 3 9259 4700 F 61 3 9259 4799 Europe T 32 2 725 11 20 F 32 2 721 86 13 Latin America T 305 593 4301 F 305 593 4300 www.gesecurity.com © 2006 General Electric Company All Rights Reserved Data Sheet 85001-0586 Issue 1 Not to be used for installation purposes. Page of 6