EMERGENCY CHECKLIST B200 EMERGENCY CHECKLIST B200 FLY THE AIRPLANE, SILENCE THE WARNING, CONFIRM EMERGENCY ENGINE FAILURES Eng Fire/Failure Unscheduled Torque Increase ENG FAIL/FIRE PRIOR TO Vr Power Lever Idle Brakes As Required If engine fire or severe damage: Condition Lever CUT-OFF Firewall Shutoff Valve Close Fire Extinguisher Actuate ENGINE FAILURE AFTER Vr (95kts) Landing Gear Up Condition Lever CUT-OFF Prop lever Feather Airspeed Vyse 121kts Flaps UP If fire warning illuminated: Firewall Shutoff Valve Close Fire Extinguisher (if instld) Actuate Complete Engine Securing or Air Start Checklist ENGINE SECURING CHECKLIST Generator Auto Ignition Autofeather Prop Sync Brake De-Ice Electrical Load Off Off Off Off Off Monitor REF ONE ENG INOP PROCEDURES 2ND ENGINE FLAMEOUT Power Lever Idle Prop Lever Do NOT Feather Condition Lever CUT-OFF Engine Air Start If no restart either engine: Landing Gear Up Flaps Up Prop Levers Feather Airspeed (GLIDE) 135kts FLY THE AIRPLANE, SILENCE THE WARNING, CONFIRM EMERGENCY ENG FIRE ON GROUND (L/R ENG) HIGH DIFFRNTIAL PRESS (>6.6PSI) Condition Lever CUT-OFF Firewall Shutoff Valve Close Ign & Eng Start Starter Only If fire warning persists: Fire Extinguisher (if instld) Actuate I FALSE ENGINE STARTS (AFM 4-16) Condition Lever CUT-OFF Hot or Hung Start Ign & Eng Start Starter Only Motor Eng for max of 40 seconds If No light off Ign & Eng Start Off Bleed Air Valves Oxygen Descend Perform Eng Clearing prior to next start Generator Switches Reset, On If Either Generator Resets: Operator Gen Loadmeter Max 100% If Neither Generator Resets: REF AFM 3-9 FUEL PRESSURE LOW (L/R) Standby Pump (failed side) REF AFM 3-6 On Envir Off As Required As Required EMERGENCY DESCENT Power Levers Idle Prop Levers Full Forward Flaps (max 200kts) Approach Landing Gear (max 181kts) Down Airspeed Max 181kts ATC Advise DUAL GENERATOR FAILURE UNSCHEDULED ELEC PITCH TRIM ELECTRICAL SMOKE OR FIRE Oxygen Mask On, 100% Communications Establish Cabin Temp Mode Off Vent Blower Auto Aft Blower Off Avionics Master Off Non-Essential Electrical Off REF AFM 3-6 Electrical REF AFM 3-7 Environmental PRESSURIZTN LOSS (ALT WARN) Oxygen Masks On, 100% Communication Establish Passenger Manual Drop-Out Pull On Descend As Required Rev ORIG Sept 2015 A/P Trim Disconnect Switch Depress Elevator Trim Switch Off REF AFM 3-11 UNSCHEDULED RUDDER BOOST Rudder Boost If condition Persists Rudder Boost Circuit Breaker REF AFM 3-12 Off Pull BLEED AIR FAIL (L/R BL AIR FAIL) Bleed Air Valve Instr & Envir Off REF AFM 3-15 AIRSTAIR/CARGO DOOR UNLOCKED All Occupants Seat belts secured DO NOT ATTEMPT TO CHECK REMAIN AWAY FROM DOOR EMERGENCY EVACUATION (Capt. Complete, F/O to Cabin) ATC Advise Parking Brake Condition Levers Prop Levers Firewall Shutoff Valves Battery/Gen Switches Evacuation Command Set CUT-OFF Feather Close Down/Off Initiate ANNUNCIATOR INDICATION WITH ASSOCIATED PROCEDURE ALT WARN AFM 3-14 L/R BL AIR FAIL AFM 3-15 L/R CHIP DETECT AFM 3A-8 L/R DC GEN AFM 3A-8 DOOR UNLOCKED AFM 3-8 DUCT OVERTEMP AFM 3A-12 L/R ENGINE FIRE AFM 3-3, 3-4 L/R ENG ICE FAIL AFM 3A-13 L/R FUEL PRESS AFM 3-6 HYD FLUID LOW AFM 3A-11 INVERTER AFM 3-9 ANNUNCIATOR INDICATION WITH NO ASSOCIATED PROCEDURE A/P FAIL A/P TRIM FAIL EXT PWR RVS NOT READY See Abnormal checklist for more indications EMERGENCY AIRSPEEDS Vmca 86kts Vxse 115kts Vyse 121kts Max Range Glide 135kts Turbulent Air Penetration 170kts Maneuvering (Va) 181kts