HPS Titan® Encapsulated Transformers for Harsh Environments HPS Titan® Encapsulated Transformers for Harsh Environments HPS Titan® Standard Features The HPS Titan® line of transformers have been designed for installation in harsh environments where efficiency and performance are key. Typical applications include institutional, commercial, industrial, petrochemical, marine, mining, etc. HPS Titan® designs provide: • Superior Performance • Compact Efficient Design • Easy Installation and Hook-up HPS Titan® Series transformers are UL Listed for “Class 1, Division 2, Groups A, B, C, and D Hazardous Locations” and also meet ABS Type Approval for “Marine Duty Service and Offshore Applications - Electrical Distribution and Propulsion”. With a North American Temperature Classification of T3C, the HPS Titan Series will remain cool under load. HPS TITAN HPS TITAN ® ® Features Single Phase Three Phase Voltage Groups 5 standard voltage groups 5 standard voltage groups Ratings 0.5 kVA to 37.5 kVA 2 kVA to 150 kVA Frequency 60 Hz (50/60 Hz on units with 380V primary) 60 Hz (50/60 Hz on units with 380V primary) Electrostatic Shield Optional on 0.50 kVA Standard on 0.75 kVA to 37.5 kVA Standard on all units Encapsulated All units are encapsulated with electrical grade silica sand and resin compounds Enclosure Heavy Duty Type 3R Optional Type 4, 4X (stainless steel) and 12 Heavy Duty Type 3R Optional Type 4, 4X (stainless steel) and 12 Optional gasket kit Terminations Front accessible separated high and low voltage lead wires or copper tabs Top accessible separate high and low voltage lead wires or copper tabs Insulation System 130°C (80°C rise) up to 1 kVA 180°C (115°C rise) 1.5 kVA to 37.5 kVA 130°C (80°C rise) up to 5 kVA (Optional on 6 kVA to 150 kVA) 180°C (115°C rise) 6 kVA to 150 kVA Mounting Standard wall mounting with keyhole mounting slots. Lifting provisions standard from 5 kVA to 37.5 kVA. Standard wall mounting with keyhole mounting slots 2 kVA to 15 kVA (Optional wall mounting kit available for 30 kVA and 45 kVA). Floor Mounted 25 kVA to 150 kVA. Lifting provisions standard on 6 kVA to 150 kVA. Three Phase Single Phase Conduit Knockouts For rear and side entry into an easily accessible and spacious wiring compartment. APPLICATIONS APPROVALS • Petrochemical Marine Industrial • • • ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, Groups A, B, C, and D Hazardous Locations) - T3C Temperature Classification UL 508 Listed - File No. E258346 UL Certificate No. 04-HS435190/1-PDA (Marine Duty Service and Offshore Applications) ABS Type Approval Approvals ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, Groups A, B, C, and D Hazardous Locations) - T3C Temperature Classification UL 508 Listed - File No. E258346 UL Certificate No. 04-HS435190/1-PDA (Marine Duty Service and Offshore Applications) ABS Type Approval Warranty All HPS standard catalog encapsulated transformers come with a 10 year limited warranty (Please refer to the HPS standard Catalog Transformer Products Warranty for full details) Options and Accessories The following options and accessories are available on all standard and custom three phase encapsulated hazardous location transformers. Optional Type 4/12 Gasket Kits Previously ordered three phase HPS Titan® encapsulated transformers in standard Type 3R rated NQT enclosures can easily be converted to a Type 4 or 12 rating by ordering and installing the appropriate gasket kit as listed in the table on page 6. Optional Stainless Steel Enclosure Oil & Gas Mining Wastewater Optional Type 4 rated NQT stainless steel enclosures are identical to the standard steel enclosure designs, but are designed using Type 316 stainless steel in accordance with ANSI, NEMA, UL and ABS requirements for indoor, outdoor and marine duty applications. If your application calls for a HPS Titan® Series unit in a stainless steel enclosure, just add the suffix ‘7’ to the end of the standard HPS part number. (e.g. P045KBKF is a standard unit. For stainless steel change the part number to P045KBKF7.) HPS Titan® Encapsulated Transformers for Harsh Environments Single Phase Product Specifications 208/240/277V Primary, 120/240V Sec. Catalog Number QC50YECB QC75YEKB Q1C0YEKF Q1C5YEKF Q002YEKF Q003YEKF Q005YEKF Q007YEKF Q010YEKF Q015YEKF Q025YEKF Q037YEKF Case Style NQ2 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ5 NQ6 NQ6 NQ7 NQ8 Approx. Weight 19 21 28 36 44 56 134 160 204 248 345 476 For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB” 600V Primary, 120/240V Sec. kVA Rating 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5 Catalog Number QC50PECB QC75PEKB Q1C0PEKF Q1C5PEKF Q002PEKF Q003PEKF Q005PEKF Q007PEKF Q010PEKF Q015PEKF Q025PEKF Q037PEKF Case Style NQ2 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ5 NQ6 NQ6 NQ7 NQ8 60 Hz A Approx. Weight 15 18 27 31 40 52 114 129 197 234 285 454 .39 C Figure 1 F A/2 P H Catalog Number QC50FECB QC75FEKB Q1C0FEKB Q1C5FEKF Q002FEKF Q003FEKF Q005FEKF Q007FEKF Q010FEKF Q015FEKF Q025FEKF Q037FEKF Case Style NQ2 NQ2 NQ3 NQ3 NQ4 NQ5 NQ5 NQ6 NQ6 NQ6 NQ7 NQ8 Approx. Weight 18 20 26 36 55 88 130 145 155 248 345 476 For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB” 240 X 480V Primary, 120/240V Sec. kVA Rating 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5 Catalog Number QC50LECB QC75LEKB Q1C0LEKB Q1C5LEKF Q002LEKF Q003LEKF Q005LEKF Q007LEKF Q010LEKF Q015LEKF Q025LEKF Q037LEKF Case Style NQ2 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ5 NQ6 NQ6 NQ7 NQ8 For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB” 60 Hz Approx. Weight 23 24 28 35 47 62 131 155 220 248 345 476 50/60 Hz kVA Rating Catalog Number Case Style Approx. Weight 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5 QC50XECB QC75XEKB Q1C0XEKB Q1C5XEKF Q002XEKF Q003XEKF Q005XEKF Q007XEKF Q010XEKF Q015XEKF Q025XEKF Q037XEKF NQ2 NQ2 NQ3 NQ3 NQ4 NQ5 NQ5 NQ6 NQ6 NQ7 CF CF 15 20 32 35 54 105 138 189 222 300 CF CF For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB” SIDE VIEW BACK VIEW B A J K (K.O.) D ØN ØM .34 C Figure 2 E BACK kVA Rating 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5 Export* Primary, 120/240V Sec. ØN K (K.O.) For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB” 50/60 Hz E G FRONT VIEW 347/380V Primary, 120/240V Sec. ØN D B BACK kVA Rating 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5 60 Hz Single Phase Enclosure Drawings and Dimensions F K (K.O.) J G CF = consult factory *Export = 190/200/208/220/2401 X 380/400/415/440/4801 Primary Volts Note 1: The primary voltage ratio of 240 or 480 is available at 60Hz only with secondary voltage of approximately 130/262V. P K (K.O.) FRONT VIEW 1 ØN H SIDE VIEW Case Style Fig # A B C D E F G H NQ0 NQ1 NQ2 NQ3 NQ4 NQ5 NQ6 NQ7 NQ8 1 1 1 1 1 2 2 2 2 3.75 4.50 5.00 5.88 7.00 10.00 12.25 14.50 14.50 5.25 5.75 4.75 5.50 6.50 7.75 9.25 10.75 10.75 7.25 7.25 9.25 10.50 11.75 17.25 20.88 21.38 27.38 2.50 3.13 3.88 4.13 5.38 7.38 9.38 11.63 11.13 5.63 5.63 7.75 8.25 9.50 15.38 18.13 18.63 24.50 6.25 6.25 8.25 9.00 10.25 15.25 18.88 19.38 24.88 1.50 1.50 1.50 1.50 1.75 2.375 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Knockout (K) sizes are actual diameter of knockout, not conduit sizes L R BACK VIEW J K1 -0.88 0.81 0.88 1.00 0.88 X 1.13 X 1.38 1.25 0.88 X 1.13 X 1.38 1.50 0.88 X 1.13 X 1.38 4.00 1.13 X 1.38 5.00 1.38 X 2.50 6.00 1.38 X 2.50 6.00 1.38 X 2.50 L M N P R -----6.00 8.00 10.00 10.00 -----0.75 0.75 0.75 0.75 0.22 0.22 0.22 0.28 0.28 0.44 0.44 0.44 0.56 1.25 1.25 1.25 1.25 1.25 1.25 2.00 2.00 2.00 -----1.68 1.68 1.81 1.81 Optional stainless steel enclosures are available HPS Titan® Encapsulated Transformers for Harsh Environments Three Phase Enclosure Drawings and Dimensions Three Phase Product Specifications 480V Primary, 208Y/120V Sec. Approx. Weight 49 86 160 262 304 478 642 1450 2100 2650 kVA Rating 2 3 6 9 15 30 45 75 112.5 150 Catalog Number P002PDKB P003PDKB P006PDKF P009PDKF P015PDKF P030PDKF P045PDKF P075PDKF P112PDKF P150PDKF Case Style NQT3 NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 Approx. Weight 51 68 146 211 270 515 740 CF CF CF LiftingLifting Provision on NQT4, NQT5 and Lifting Provision on NQT4, Provision NQT5 Lifting on and Provision NQT4, NQT6. NQT5 onNQT6. NQT4, and NQT6. NQT5 and NQT6. A A A D D D 1.26 1.26 H Easy access to wiring Easycompartment access toEasy wiring access compartment to wiring compartment via (4) HHCS on top viacover. (4) HHCS on viatop (4) cover. HHCS on top cover. q 1.0(2) q 1.0(2) B Figure 1 E q N(4) C H 1.26 H C E G J J q 1.0(2) B E J B C K (K,O)(4) GG BACK Case Style NQT3 NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 60Hz BACK Catalog Number P002KBKB P003KBKB P006KBKF P009KBKF P015KBKF P030KBKF P045KBKF P075KBKF P112KBKF P150KBKF 600V (Y) Primary, 240V (D) Sec. BACK kVA Rating 2 3 6 9 15 30 45 75 112.5 150 60Hz RK (K,O)(4) R K (K,O)(4) G G R G q N(4) q N(4) P P P CF = consult factory All Dimensions in Inches All Dimensions All in Inches Dimensions in Inches FRONTVIEW VIEW FRONT VIEW FRONT VIEW SIDE VIEW SIDE VIEW SIDE VIEWREAR VIEW REAR VIEW REARVIEW VIEW REAR SIDE VIEW FRONT 480V(D) Primary, 240V(D) Sec. Case Style NQT3 NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 Approx. Weight 52 68 182 250 312 540 650 1230 2100 2650 kVA Rating 2 3 6 9 15 30 45 75 112.5 150 Catalog Number P002QKKB P003QKKB P006QKKF P009QKKF P015QKKF P030QKKF P045QKKF P075QKKF P112QKKF P150QKKF 60Hz Case Style NQT3 NQT3 NQT4 NQT5 NQT7 NQT7 NQT8 NQT9 NQT10 NQT11 Approx. Weight 65 69 190 270 380 472 680 1650 CF CF AA FF LL A F LHH 0.69 0.69 0.69Typ. Typ. Typ. JJ H Figure 2 RR J R 0.56 0.56 0.56Typ. Typ. Typ. Easy access Easytoaccess wiring to compartment wiring compartment viavia via Easy access to wiring compartment ABS approved ABS approved hardware hardware onon toptop cover. on top cover. ABS approved hardware cover. K (K,O)(4) KK(K,O)(4) (K,O)(4) The Lifting TheProvisions Lifting Provisions onon NQT7, on NQT7, The Lifting Provisions NQT7, NQT8 and NQT8 NQT9 andenclosures NQT9 enclosures are NQT8 and NQT9 enclosures are are located located in the wiring in the compartment. wiring compartment. located in the wiring compartment. CC GGC G BACK Catalog Number P002KDKB P003KDKB P006KDKF P009KDKF P015KDKF P030KDKF P045KDKF P075KDKF P112KDKF P150KDKF 600, 480V Primary, 480Y/277V Sec. BACK BACK kVA Rating 2 3 6 9 15 30 45 75 112.5 150 60Hz MM M CF = consult factory 600V Primary, 208Y/120V Sec. kVA Rating 2 3 6 9 15 30 45 75 112.5 150 Catalog Number P002PBKB P003PBKB P006PBKF P009PBKF P015PBKF P030PBKF P045PBKF P075PBKF P112PBKF P150PBKF Case Style NQT3 NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 60Hz Approx. Weight 85 94 146 211 340 605 770 1350 3150 3200 3.0 3.0 3.0 Optional Gasket Kits Selection Table Enclosure Case Style NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 DD EE BB D FRONT FRONT VIEW FRONT VIEW FRONT VIEWVIEW θ θN(4) θ N(4) N(4) 0.63 0.63 0.63Typ. Typ. Typ. E B AllAll Dimensions All Dimensions in in Inches in Inches Dimensions Inches SIDE SIDE VIEW SIDE VIEW SIDEVIEW VIEW REAR REAR VIEW VIEW REAR VIEW REAR VIEW Gasket Kit P/N NQT3GK NQT4GK NQT5GK NQT6GK NQT7GK NQT8GK NQT9GK NQT10GK NQT11GK 1 Case Style Fig # A B C D E F G H J K1 L M N P R NQT2 NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 1 1 1 1 1 2 2 2 2 2 9.38 12.38 15.19 16.63 19.25 20.25 22.25 31.25 38.44 37.38 4.94 5.44 6.94 10.25 10.44 13.00 13.00 16.00 26.00 30.00 8.63 11.13 15.13 16.63 16.63 23.38 28.38 29.88 39.13 45.63 8.38 11.38 13.88 14.50 17.50 12.00 14.00 18.00 23.50 23.50 4.00 6.50 9.25 8.25 8.25 11.75 11.75 14.75 24.00 28.00 -----11.38 11.38 14.13 20.80 22.00 7.06 9.50 13.56 13.88 13.56 17.94 21.94 23.94 32.50 39.00 2.38 2.38 1.88 2.69 2.69 2.50 2.50 2.75 6.40 6.95 4.50 5.50 5.50 10.00 12.50 13.75 15.75 22.75 24.75 24.75 0.88 X 1.13 0.88 X 1.13 0.88 X 1.13 1.38 X 1.75 1.38 X 2.50 1.38 X 2.50 1.38 X 2.50 2.00 X 3.00 2.50 X 3.63 2.50 X 3.63 -----4.25 4.25 6.50 8.00 8.00 -----17.94 21.94 23.94 32.50 39.00 0.28 0.28 0.28 0.41 0.41 0.56 0.56 0.56 0.69 0.69 1.81 1.81 3.06 4.50 4.50 ------ 2.44 3.44 4.19 2.25 2.50 2.13 2.13 3.13 6.84 6.31 Knockout (K) sizes are actual diameter of knockout, not conduit sizes Optional stainless steel enclosures are available EUROPE CANADA EUROPE UNITED INDIA STATES CANADA HPS 595 Southgate Drive Guelph, Ontario N1G 3W6 Tel: (519) 822-2441 Fax: (519) 822-9701 Toll Free: 1-888-798-8882 sales@hammondpowersolutions.com EUROPE Hammond Power Solutions Via Angelo Schiatti, 12 36040 Meledo di Sarego (VI) Italy Tel: +39 0444 822 000 Fax: +39 0444 822 065 info@hpseurope.eu UNITED STATES HPS 1100 Lake Street Baraboo, Wisconsin 53913-2866 Tel: (608) 356-3921 Fax: (608) 355-7623 Toll Free: 1-866-705-4684 sales@hammondpowersolutions.com INDIA PETE - Hammond Power Solutions Pvt. Ltd. G-9 to 11, Bhavya’s Sree Arcade Erragadda, Hyderabad, A.P. - 500 018 Tel: 040-23813593, 23812291 Fax: 040-23706741 marketing@petetransformers.com INDIA Scan this QR code with your smartphone to view additional information on the HPS Titan®. Distributed by: www.hammondpowersolutions.com Literature No.: TSETB8 Issue Date: October 2014