HPS Titan - Hammond Power Solutions

advertisement
HPS Titan®
Encapsulated Transformers
for Harsh Environments
HPS Titan®
Encapsulated Transformers for Harsh Environments
HPS Titan® Standard Features
The HPS Titan® line of transformers have been designed for installation in harsh environments where efficiency and
performance are key. Typical applications include institutional, commercial, industrial, petrochemical, marine, mining, etc.
HPS Titan® designs provide:
• Superior Performance
• Compact Efficient Design
• Easy Installation and Hook-up
HPS Titan® Series transformers are UL Listed for “Class 1, Division 2, Groups A, B, C, and D Hazardous Locations” and also
meet ABS Type Approval for “Marine Duty Service and Offshore Applications - Electrical Distribution and Propulsion”.
With a North American Temperature Classification of T3C, the HPS Titan Series will remain cool under load.
HPS TITAN
HPS TITAN
®
®
Features
Single Phase
Three Phase
Voltage Groups
5 standard voltage groups
5 standard voltage groups
Ratings
0.5 kVA to 37.5 kVA
2 kVA to 150 kVA
Frequency
60 Hz (50/60 Hz on units with 380V primary)
60 Hz (50/60 Hz on units with 380V primary)
Electrostatic Shield
Optional on 0.50 kVA
Standard on 0.75 kVA to 37.5 kVA
Standard on all units
Encapsulated
All units are encapsulated with electrical grade silica sand and resin compounds
Enclosure
Heavy Duty Type 3R
Optional Type 4, 4X (stainless steel) and 12
Heavy Duty Type 3R
Optional Type 4, 4X (stainless steel) and 12
Optional gasket kit
Terminations
Front accessible separated high and low
voltage lead wires or copper tabs
Top accessible separate high and low voltage
lead wires or copper tabs
Insulation System
130°C (80°C rise) up to 1 kVA
180°C (115°C rise) 1.5 kVA to 37.5 kVA
130°C (80°C rise) up to 5 kVA
(Optional on 6 kVA to 150 kVA)
180°C (115°C rise) 6 kVA to 150 kVA
Mounting
Standard wall mounting with keyhole mounting
slots.
Lifting provisions standard from 5 kVA to 37.5
kVA.
Standard wall mounting with keyhole mounting
slots 2 kVA to 15 kVA (Optional wall mounting
kit available for 30 kVA and 45 kVA).
Floor Mounted 25 kVA to 150 kVA.
Lifting provisions standard on 6 kVA to 150
kVA.
Three Phase
Single Phase
Conduit Knockouts For rear and side entry into an easily accessible and spacious wiring compartment.
APPLICATIONS
APPROVALS
•
Petrochemical
Marine
Industrial
•
•
•
ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2,
Groups A, B, C, and D Hazardous Locations) - T3C Temperature
Classification
UL 508 Listed - File No. E258346
UL Certificate No. 04-HS435190/1-PDA (Marine Duty Service
and Offshore Applications)
ABS Type Approval
Approvals
ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, Groups A, B, C, and D Hazardous
Locations) - T3C Temperature Classification
UL 508 Listed - File No. E258346
UL Certificate No. 04-HS435190/1-PDA (Marine Duty Service and Offshore Applications)
ABS Type Approval
Warranty
All HPS standard catalog encapsulated transformers come with a 10 year limited warranty (Please
refer to the HPS standard Catalog Transformer Products Warranty for full details)
Options and Accessories
The following options and accessories are available on all standard and custom three phase encapsulated hazardous
location transformers.
Optional Type 4/12 Gasket Kits
Previously ordered three phase HPS Titan® encapsulated transformers in standard Type 3R rated NQT enclosures can
easily be converted to a Type 4 or 12 rating by ordering and installing the appropriate gasket kit as listed in the table on
page 6.
Optional Stainless Steel Enclosure
Oil & Gas
Mining
Wastewater
Optional Type 4 rated NQT stainless steel enclosures are identical to the standard steel enclosure designs, but are
designed using Type 316 stainless steel in accordance with ANSI, NEMA, UL and ABS requirements for indoor, outdoor and
marine duty applications. If your application calls for a HPS Titan® Series unit in a stainless steel enclosure, just add the
suffix ‘7’ to the end of the standard HPS part number. (e.g. P045KBKF is a standard unit. For stainless steel change the part
number to P045KBKF7.)
HPS Titan®
Encapsulated Transformers for Harsh Environments
Single Phase Product Specifications
208/240/277V Primary, 120/240V Sec.
Catalog
Number
QC50YECB
QC75YEKB
Q1C0YEKF
Q1C5YEKF
Q002YEKF
Q003YEKF
Q005YEKF
Q007YEKF
Q010YEKF
Q015YEKF
Q025YEKF
Q037YEKF
Case
Style
NQ2
NQ2
NQ3
NQ3
NQ4
NQ4
NQ5
NQ5
NQ6
NQ6
NQ7
NQ8
Approx.
Weight
19
21
28
36
44
56
134
160
204
248
345
476
For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB”
600V Primary, 120/240V Sec.
kVA
Rating
0.50
0.75
1
1.5
2
3
5
7.5
10
15
25
37.5
Catalog
Number
QC50PECB
QC75PEKB
Q1C0PEKF
Q1C5PEKF
Q002PEKF
Q003PEKF
Q005PEKF
Q007PEKF
Q010PEKF
Q015PEKF
Q025PEKF
Q037PEKF
Case
Style
NQ2
NQ2
NQ3
NQ3
NQ4
NQ4
NQ5
NQ5
NQ6
NQ6
NQ7
NQ8
60 Hz
A
Approx.
Weight
15
18
27
31
40
52
114
129
197
234
285
454
.39
C
Figure 1
F
A/2
P
H
Catalog
Number
QC50FECB
QC75FEKB
Q1C0FEKB
Q1C5FEKF
Q002FEKF
Q003FEKF
Q005FEKF
Q007FEKF
Q010FEKF
Q015FEKF
Q025FEKF
Q037FEKF
Case
Style
NQ2
NQ2
NQ3
NQ3
NQ4
NQ5
NQ5
NQ6
NQ6
NQ6
NQ7
NQ8
Approx.
Weight
18
20
26
36
55
88
130
145
155
248
345
476
For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB”
240 X 480V Primary, 120/240V Sec.
kVA
Rating
0.50
0.75
1
1.5
2
3
5
7.5
10
15
25
37.5
Catalog
Number
QC50LECB
QC75LEKB
Q1C0LEKB
Q1C5LEKF
Q002LEKF
Q003LEKF
Q005LEKF
Q007LEKF
Q010LEKF
Q015LEKF
Q025LEKF
Q037LEKF
Case
Style
NQ2
NQ2
NQ3
NQ3
NQ4
NQ4
NQ5
NQ5
NQ6
NQ6
NQ7
NQ8
For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB”
60 Hz
Approx.
Weight
23
24
28
35
47
62
131
155
220
248
345
476
50/60 Hz
kVA
Rating
Catalog
Number
Case
Style
Approx.
Weight
0.50
0.75
1
1.5
2
3
5
7.5
10
15
25
37.5
QC50XECB
QC75XEKB
Q1C0XEKB
Q1C5XEKF
Q002XEKF
Q003XEKF
Q005XEKF
Q007XEKF
Q010XEKF
Q015XEKF
Q025XEKF
Q037XEKF
NQ2
NQ2
NQ3
NQ3
NQ4
NQ5
NQ5
NQ6
NQ6
NQ7
CF
CF
15
20
32
35
54
105
138
189
222
300
CF
CF
For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB”
SIDE VIEW
BACK VIEW
B
A
J
K (K.O.)
D
ØN
ØM
.34
C
Figure 2
E
BACK
kVA
Rating
0.50
0.75
1
1.5
2
3
5
7.5
10
15
25
37.5
Export* Primary, 120/240V Sec.
ØN
K (K.O.)
For shielded unit 0.50 kVA, replace the suffix “CB” with a “KB”
50/60 Hz
E
G
FRONT VIEW
347/380V Primary, 120/240V Sec.
ØN
D
B
BACK
kVA
Rating
0.50
0.75
1
1.5
2
3
5
7.5
10
15
25
37.5
60 Hz
Single Phase Enclosure Drawings and Dimensions
F
K (K.O.)
J
G
CF = consult factory
*Export = 190/200/208/220/2401 X 380/400/415/440/4801 Primary Volts
Note 1: The primary voltage ratio of 240 or 480 is available at 60Hz
only with secondary voltage of approximately 130/262V.
P
K (K.O.)
FRONT VIEW
1
ØN
H
SIDE VIEW
Case Style
Fig #
A
B
C
D
E
F
G
H
NQ0
NQ1
NQ2
NQ3
NQ4
NQ5
NQ6
NQ7
NQ8
1
1
1
1
1
2
2
2
2
3.75
4.50
5.00
5.88
7.00
10.00
12.25
14.50
14.50
5.25
5.75
4.75
5.50
6.50
7.75
9.25
10.75
10.75
7.25
7.25
9.25
10.50
11.75
17.25
20.88
21.38
27.38
2.50
3.13
3.88
4.13
5.38
7.38
9.38
11.63
11.13
5.63
5.63
7.75
8.25
9.50
15.38
18.13
18.63
24.50
6.25
6.25
8.25
9.00
10.25
15.25
18.88
19.38
24.88
1.50
1.50
1.50
1.50
1.75
2.375
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
Knockout (K) sizes are actual diameter of knockout, not conduit sizes
L
R
BACK VIEW
J
K1
-0.88
0.81
0.88
1.00 0.88 X 1.13 X 1.38
1.25 0.88 X 1.13 X 1.38
1.50 0.88 X 1.13 X 1.38
4.00
1.13 X 1.38
5.00
1.38 X 2.50
6.00
1.38 X 2.50
6.00
1.38 X 2.50
L
M
N
P
R
-----6.00
8.00
10.00
10.00
-----0.75
0.75
0.75
0.75
0.22
0.22
0.22
0.28
0.28
0.44
0.44
0.44
0.56
1.25
1.25
1.25
1.25
1.25
1.25
2.00
2.00
2.00
-----1.68
1.68
1.81
1.81
Optional stainless steel enclosures are available
HPS Titan®
Encapsulated Transformers for Harsh Environments
Three Phase Enclosure Drawings and Dimensions
Three Phase Product Specifications
480V Primary, 208Y/120V Sec.
Approx.
Weight
49
86
160
262
304
478
642
1450
2100
2650
kVA
Rating
2
3
6
9
15
30
45
75
112.5
150
Catalog
Number
P002PDKB
P003PDKB
P006PDKF
P009PDKF
P015PDKF
P030PDKF
P045PDKF
P075PDKF
P112PDKF
P150PDKF
Case
Style
NQT3
NQT3
NQT4
NQT5
NQT6
NQT7
NQT8
NQT9
NQT10
NQT11
Approx.
Weight
51
68
146
211
270
515
740
CF
CF
CF
LiftingLifting
Provision
on
NQT4,
NQT5
and
Lifting Provision
on
NQT4,
Provision
NQT5
Lifting
on
and
Provision
NQT4,
NQT6.
NQT5
onNQT6.
NQT4,
and NQT6.
NQT5 and NQT6.
A
A
A
D
D
D 1.26
1.26
H
Easy access to wiring
Easycompartment
access toEasy
wiring
access
compartment
to wiring compartment
via (4) HHCS on top
viacover.
(4) HHCS on
viatop
(4) cover.
HHCS on top cover.
q 1.0(2)
q 1.0(2)
B
Figure 1
E
q N(4)
C
H
1.26
H
C
E
G
J
J
q 1.0(2)
B
E
J
B
C
K (K,O)(4)
GG
BACK
Case
Style
NQT3
NQT3
NQT4
NQT5
NQT6
NQT7
NQT8
NQT9
NQT10
NQT11
60Hz
BACK
Catalog
Number
P002KBKB
P003KBKB
P006KBKF
P009KBKF
P015KBKF
P030KBKF
P045KBKF
P075KBKF
P112KBKF
P150KBKF
600V (Y) Primary, 240V (D) Sec.
BACK
kVA
Rating
2
3
6
9
15
30
45
75
112.5
150
60Hz
RK (K,O)(4) R
K (K,O)(4)
G
G
R
G
q N(4)
q N(4)
P
P
P
CF = consult factory
All Dimensions in Inches
All Dimensions All
in Inches
Dimensions in Inches
FRONTVIEW
VIEW
FRONT VIEW
FRONT VIEW SIDE VIEW
SIDE
VIEW
SIDE VIEWREAR VIEW REAR VIEW
REARVIEW
VIEW
REAR
SIDE
VIEW
FRONT
480V(D) Primary, 240V(D) Sec.
Case
Style
NQT3
NQT3
NQT4
NQT5
NQT6
NQT7
NQT8
NQT9
NQT10
NQT11
Approx.
Weight
52
68
182
250
312
540
650
1230
2100
2650
kVA
Rating
2
3
6
9
15
30
45
75
112.5
150
Catalog
Number
P002QKKB
P003QKKB
P006QKKF
P009QKKF
P015QKKF
P030QKKF
P045QKKF
P075QKKF
P112QKKF
P150QKKF
60Hz
Case
Style
NQT3
NQT3
NQT4
NQT5
NQT7
NQT7
NQT8
NQT9
NQT10
NQT11
Approx.
Weight
65
69
190
270
380
472
680
1650
CF
CF
AA
FF
LL
A
F
LHH
0.69
0.69
0.69Typ.
Typ. Typ.
JJ
H
Figure 2
RR
J
R
0.56
0.56
0.56Typ.
Typ. Typ.
Easy
access
Easytoaccess
wiring
to
compartment
wiring compartment
viavia
via
Easy
access
to
wiring
compartment
ABS
approved
ABS approved
hardware
hardware
onon
toptop
cover.
on
top cover.
ABS
approved
hardware
cover.
K (K,O)(4)
KK(K,O)(4)
(K,O)(4)
The
Lifting
TheProvisions
Lifting
Provisions
onon
NQT7,
on NQT7,
The
Lifting
Provisions
NQT7,
NQT8
and
NQT8
NQT9
andenclosures
NQT9
enclosures
are
NQT8
and
NQT9
enclosures
are are
located
located
in
the
wiring
in
the
compartment.
wiring
compartment.
located in the wiring compartment.
CC GGC G
BACK
Catalog
Number
P002KDKB
P003KDKB
P006KDKF
P009KDKF
P015KDKF
P030KDKF
P045KDKF
P075KDKF
P112KDKF
P150KDKF
600, 480V Primary, 480Y/277V Sec.
BACK
BACK
kVA
Rating
2
3
6
9
15
30
45
75
112.5
150
60Hz
MM
M
CF = consult factory
600V Primary, 208Y/120V Sec.
kVA
Rating
2
3
6
9
15
30
45
75
112.5
150
Catalog
Number
P002PBKB
P003PBKB
P006PBKF
P009PBKF
P015PBKF
P030PBKF
P045PBKF
P075PBKF
P112PBKF
P150PBKF
Case
Style
NQT3
NQT3
NQT4
NQT5
NQT6
NQT7
NQT8
NQT9
NQT10
NQT11
60Hz
Approx.
Weight
85
94
146
211
340
605
770
1350
3150
3200
3.0
3.0 3.0
Optional Gasket Kits
Selection Table
Enclosure
Case Style
NQT3
NQT4
NQT5
NQT6
NQT7
NQT8
NQT9
NQT10
NQT11
DD
EE
BB
D
FRONT
FRONT
VIEW
FRONT
VIEW
FRONT
VIEWVIEW
θ θN(4)
θ N(4)
N(4)
0.63
0.63
0.63Typ.
Typ. Typ.
E
B
AllAll
Dimensions
All Dimensions
in in
Inches
in Inches
Dimensions
Inches
SIDE
SIDE
VIEW
SIDE
VIEW
SIDEVIEW
VIEW
REAR
REAR
VIEW
VIEW
REAR
VIEW
REAR
VIEW
Gasket Kit P/N
NQT3GK
NQT4GK
NQT5GK
NQT6GK
NQT7GK
NQT8GK
NQT9GK
NQT10GK
NQT11GK
1
Case Style
Fig #
A
B
C
D
E
F
G
H
J
K1
L
M
N
P
R
NQT2
NQT3
NQT4
NQT5
NQT6
NQT7
NQT8
NQT9
NQT10
NQT11
1
1
1
1
1
2
2
2
2
2
9.38
12.38
15.19
16.63
19.25
20.25
22.25
31.25
38.44
37.38
4.94
5.44
6.94
10.25
10.44
13.00
13.00
16.00
26.00
30.00
8.63
11.13
15.13
16.63
16.63
23.38
28.38
29.88
39.13
45.63
8.38
11.38
13.88
14.50
17.50
12.00
14.00
18.00
23.50
23.50
4.00
6.50
9.25
8.25
8.25
11.75
11.75
14.75
24.00
28.00
-----11.38
11.38
14.13
20.80
22.00
7.06
9.50
13.56
13.88
13.56
17.94
21.94
23.94
32.50
39.00
2.38
2.38
1.88
2.69
2.69
2.50
2.50
2.75
6.40
6.95
4.50
5.50
5.50
10.00
12.50
13.75
15.75
22.75
24.75
24.75
0.88 X 1.13
0.88 X 1.13
0.88 X 1.13
1.38 X 1.75
1.38 X 2.50
1.38 X 2.50
1.38 X 2.50
2.00 X 3.00
2.50 X 3.63
2.50 X 3.63
-----4.25
4.25
6.50
8.00
8.00
-----17.94
21.94
23.94
32.50
39.00
0.28
0.28
0.28
0.41
0.41
0.56
0.56
0.56
0.69
0.69
1.81
1.81
3.06
4.50
4.50
------
2.44
3.44
4.19
2.25
2.50
2.13
2.13
3.13
6.84
6.31
Knockout (K) sizes are actual diameter of knockout, not conduit sizes
Optional stainless steel enclosures are available
EUROPE
CANADA
EUROPE
UNITED
INDIA STATES
CANADA
HPS
595 Southgate Drive
Guelph, Ontario N1G 3W6
Tel: (519) 822-2441
Fax: (519) 822-9701
Toll Free: 1-888-798-8882
sales@hammondpowersolutions.com
EUROPE
Hammond Power Solutions
Via Angelo Schiatti, 12
36040 Meledo di Sarego (VI) Italy
Tel: +39 0444 822 000
Fax: +39 0444 822 065
info@hpseurope.eu
UNITED STATES
HPS
1100 Lake Street
Baraboo, Wisconsin 53913-2866
Tel: (608) 356-3921
Fax: (608) 355-7623
Toll Free: 1-866-705-4684
sales@hammondpowersolutions.com
INDIA
PETE - Hammond Power Solutions Pvt. Ltd.
G-9 to 11, Bhavya’s Sree Arcade
Erragadda, Hyderabad, A.P. - 500 018
Tel: 040-23813593, 23812291
Fax: 040-23706741
marketing@petetransformers.com
INDIA
Scan this QR code with your
smartphone to view additional
information on the HPS Titan®.
Distributed by:
www.hammondpowersolutions.com
Literature No.: TSETB8
Issue Date: October 2014
Download