C60N/H miniature circuit breakers Multi 9 Merlin Gerin The C60N circuit-breaker is a miniature circuit-breaker used for the protection of circuits in industry and the tertiary sector. It ensures the following functions: protection against short-circuit and overload currents, isolation, protection of persons against indirect contact. Operation ■ 1 to 4-pole circuit-breakers. ■ Control and protection: - B curve: against circuit overcurrents including protection of persons for longer cables than with C curve types, - C curve: against the overcurrents of circuits feeding conventional loads, - D curve: against the current of installations containing loads with high inrush currents (motors, transformers). Adv Adv antag antag es ■ Conformity with national and international standards: AS/NZS 4898 (EN 60 898). ■ Ratings from 1 to 63 A. ■ Breaking capacity of 6 000/10 000 A under 240/415 V for C60N/H. ■ Clip-on electrical auxiliaries and add-on accessories. The rang e C60N circuit-breaker Remote control (AUS01PL18-A) A1 MERLIN GERIN multi 9 C60N MERLIN GERIN multi 9 Tm C63 C60 1-2 A 400Va 6000 a S 230V 10kA IEC 947.2 D auto A 24182 18310 O - OFF 1P A2 and/or Auxiliaries MERLIN GERIN MERLIN GERIN multi 9 C60N 400Va 6000 1 3 10kA IEC 947.2 24206 (AUS01PL06-A) SD MERLIN GERIN MERLIN GERIN multi 9 MX OF multi 9 MN 110.130V 220.415Va 26946 220.415Va 26960 D1 D2 U< reset 26927 26924 400Va 6000 N 1 10kA IEC 947.2 24193 N 2 O - OFF O - OFF 1P + N OF C40 2 4 O - OFF Test multi 9 C60N or C40 O - OFF + Vigi C60 module MERLIN GERIN multi 9 vigi C60 (AUS01PL08-A) T02 I N 0,030A a N/1 3 T N/2 4 test 26509 2P 2P + + MERLIN GERIN multi 9 C60N C25 400Va 6000 1 3 5 10kA IEC 947.2 2 4 6 24217 O - OFF O - OFF O - OFF MERLIN GERIN multi 9 vigi C60 I N 0,030A a T02 5 N/1 3 T N/2 4 6 test 26531 3P OF SD MX + OF 3P MN + MERLIN GERIN multi 9 C60N C63 400Va 6000 1 3 5 7 10kA IEC 947.2 2 4 6 8 23974 O - OFF O - OFF O - OFF O - OFF MERLIN GERIN multi 9 vigi C60 I N 0,300A a N/1 3 5 T02 7 T N/2 4 26533 6 8 test 4P 4P C 2 1 C 2 Comb busbars 1 1 1 1 1 Clip-on markers 1 1 1 1 1 1 1 Padlocking device Rotary handle Accessories Terminal shield Screw shield (AUS01PL07-A) Get more with the world’s Power & Control specialist SELECTION TABLE type rating (A) catalogue number C curve C60N 1P 1 Width in mod. of 9mm - 2 2 2P Width in mod. of 9mm - 4 1 3 2 4 3P Width in mod. of 9mm - 6 1 3 2 5 4 6 type rating (A) 1 2 4 6 10 16 20 25 32 40 50 63 1 2 4 6 10 16 20 25 32 40 50 63 1 2 4 6 10 16 20 25 32 40 50 63 B Curve 25797 25798 25800 25801 25802 25803 25804 25805 25806 25807 25808 25809 25811 25812 25814 25815 25816 25817 25818 25819 25820 25821 25822 25823 25825 25826 25828 25829 25830 25831 25832 25833 25834 25835 25836 25837 C Curve D Curve 25639 25640 25642 25643 25644 25645 25646 25647 25648 25649 25651 25652 25653 25654 25656 25656 25658 25659 25660 25661 25662 25663 25665 25666 25667 25668 25670 25671 25672 25673 25674 25675 25676 25677 25679 25680 25007 25008 25010 25011 25012 25013 25014 25015 25016 25017 25018 25019 25695 25696 25698 25699 25700 25701 25702 25703 25704 25705 25707 25708 25709 25710 25712 25713 25714 25715 25716 25717 25718 25719 25721 25722 25723 25724 25726 25727 25728 25729 25730 25731 25732 25733 25735 25736 25211 25212 25214 25215 25216 25217 25218 25219 25220 25221 25222 25223 C60H 1P 1 2 Width in mod. of 9mm - 2 2P 1 3 2 4 Width in mod. of 9mm - 4 3P 1 3 5 2 4 6 Width in mod. of 9mm - 6 4P 1 3 5 7 2 4 6 8 Width in mod. of 9mm - 8 1 2 4 6 10 16 20 25 32 40 50 63 1 2 4 6 10 16 20 25 32 40 50 63 1 2 4 6 10 16 20 25 32 40 50 63 1 2 4 6 10 16 20 25 32 40 50 63 25839 25840 25841 25842 25843 25844 25845 25846 25847 25848 25849 25850 25852 25853 25854 25855 25856 25857 25858 25859 25860 25861 25862 25863 25865 25866 25867 25868 25869 25870 25871 25872 25873 25874 25875 25876 25878 25879 25880 25881 25882 25883 25884 25885 25886 25887 25888 25889 IMPLEMENTA IMPLEMENTATION ■ Designed for installation in modular enclosures and switchboards. ■ Easy mounting on symmetrical rail. ■ Easy connection using serrated tunnel terminals with flap. ■ Captive screws with mixed +/- indent. ■ Simplified clip-on combination of circuit-breaker with auxiliaries. ■ Use of comb busbars to simplify circuit-breaker connection. C 2 C 2 MERLIN GERIN MERLIN GERIN OF multi 9 C60N multi 9 C60N C25 C25 Test 400Va 6000 24204 O - OFF 400Va 6000 1 3 10kA IEC 947.2 26924 2 4 O - OFF MERLIN GERIN MERLIN GERIN multi 9 MN multi 9 C60N D1 D2 U< 220.415Va 26960 1 3 10kA IEC 947.2 24204 O - OFF 2 4 O - OFF C25 400Va 6000 1 3 10kA IEC 947.2 24204 O - OFF 2 4 O - OFF TECHNICAL DA DATA Electrical data ■ Power circuit: - voltage rating: 440 V AC, - ratings from 0.5 to 63 A set at 30C (40C for D curve), - breaking capacity: C60N rating (A) 1 to 63 C60H rating (A) 1 to 63 number of poles voltage (VAC) 1P 2P, 3P, 230 to 240 400 to 415 number of poles voltage (VAC) 1P 2P, 3P, 4P 230 to 240 400 to 415 breaking capacity (A) 6 000 6 000 breaking capacity (A) 10 000 10 000 - limitation class (EN 60 898): 3, fast closing: increased withstand to the high inrush currents of certain loads, - isolation with positive break indication: opening is indicated by a green strip on the device’s control toggle. This indicates that all poles are open. Tripping cur ves: ■ B curve: - magnetic releases operate between 3 and 5 ln. ■ C curve: - magnetic releases operate between 5 and 10 ln. ■ D curve: magnetic releases operate between 10 and 14 ln. Mechanical Mechanical data ■ Connection by tunnel terminals for the following cables: - 16 mm2 flexible or 25 mm2 stranded for up to 25 A ratings, - 25 mm2 flexible or 35 mm2 stranded for ≥32 A ratings. ■ Durability: 20 000 cycles (O-C). ■ Dimensions (w x h x d mm): 18 x N (number of poles) x 81 x 70. ■ Weight (g): 1P: 120, 240, 2P: 240, 3P: 360, 4P: 480. ENVIRONMENT ENVIRONMENT ■ Tropicalisation: treatment 2 (relative humidity: 95 % at 55C). - Degree of protection: - of enclosure: IP 40, - of terminals: IP 20. ■ Operating temperature: - 5C to +60C. ■ Storage temperature: - 40C to +100C. Approval No: N13634 SCHNEIDER ELECTRIC HELP CENTRE Tel: 1300 369 233 Fax: 1300 369 288 Email: help@schneider.com.au www.schneider-electric.com.au AUS01PL04-A