Triple Shielded Cable

advertisement
...Cable for professionals
130611 • 02109
Triple Shielded Cable
F O R PR O F ES S IO N AL S
Low
DC loop
resistance
Meter
marking
High
screening
efficiency,
class A
Better
ingress
protection
in the
return band
www.macab.com
The distribution networks of today are exposed for ingress from other communication
networks as LTE, 3G, 4G etc and this means that the coaxial cables have to fulfil very high
screening demands to be able to protect the systems from this type of ingress. Choosing
Macab’s triple shielded coaxial cable gives you a top of the line cable with copper inner
conductor and a very high screening efficiency.
Inner conductor
Classification:
In drop cables the most common used conductors are
electrolytic copper (CU) or copper clad steel (CCS). The CCS
conductor can be used thanks to the radio frequency signal
is carried only on the surface of the conductor (skin effect).
CCS has much higher loop resistance than the CU conductor
and that is a very important factor when the cable is used for
remote powering.
Freq range
MHz
5–30
30–1000
1000–2000
2000–3000
Class B
< 15
75
65
55
Class A
<5
85
75
65
Class A+
< 2,5
95
85
75
mΩ/m
dB
dB
dB
Foil
The first shield consists of a polyester aluminium foil bonded
to the dielectric which guarantees 100% coverage. The foil is
mainly for preventing ingress of high frequencies. Depending
of the thickness and the overlap of the foil different shielding
efficiencies will be achieved.
Dielectric
Gasinjected foam is the latest technology for producing
the dielectric of coaxial cables. A nitrogen gas is physically
injected into polyethylene (HPDE) which produces a foam
with excellent mechanical and ageing performances.
Braid
Shielding
To increase the shielding efficiency you can add a braid. If the
braiding coverage is 40% you can reach an efficiency of appr
75 dB. Higher braiding coverage will increase the shielding
efficiency. The braid gives better shielding performances for
lower frequencies. The efficiency is complex and depends of
many different parameters such as how many strands you
are using in the braid, the diameter of the strands, number
of groups of strands, the length of the twisting and what
material you are using.
The shielding is introduced to protect the RF signals from
external interferences. The shielding can be made in several
different ways as single, double, triple and quad. The most
common solution today is the triple shielded. The way to test
and measure the shielding efficiency is defined by EN50117
and the methods are Transfer Impedance for low frequencies
(<30 MHz) and Screening Attenuation for higher frequencies.
PVC, PE, LSNH Jacket
Jackets in
several materials
Phone: +46 410 36 36 10 • Fax: +46 410 36 36 01
Screening attenuation
2
Alu foil
Overlapped foil
improves the total
screening performance
www.macab.com
...a step into a digital world
Foil
The LSNH, halogen free jacket, is a type of jacket that
doesn’t generate halogens, have a low smoke emission and
is flame and fire retardant when burning.
An extra foil as outer shielding increases the shielding
performance specially for the high frequencies and it’s also
an extra protection for moisture.
Packaging
Jacket
For your convenience we can offer you different type of
packaging.
Depending in which environment you are installing the
cable you have several different type of jacket to choose in
between.
100 m plastic spool
250 m plastic spool in a box
300/500 m wooden drums
Indoor........................ PVC, white, –20°C installation temperature
Outdoor .................... PE, black
Public surroundings... LSNH, white UV and moisture protected
Type
RG-59T
RG-6T
100 m spool,white PVC
411 12 01
411 12 31
250 m spool in a box, white PVC
411 12 05
411 12 41
500 m drum,white PVC
411 12 20
411 12 50
100 m spool, black PE
411 12 24
411 12 49
250 m spool in a box,black PE
411 12 26
411 12 57
RG-11T
PVC-jacket
411 12 80
PE-jacket
411 12 60
300 m drum, black PE
411 12 53
500 m drum, black PE
411 12 70
LSNH-jacket, UV and water resistant
100 m spool, white halogen free
411 12 22
411 12 43
250 m spool in a box, white halogen free
411 12 23
411 12 44
411 12 88
300 m drum, white halogen free
411 12 48
500 m drum, white halogen free
AL braid >60%
Braided screen
handles the lower
frequencies
411 12 89
ALU foil bonded
Gasinjected PE foam
Bonded foil gives better
screening performance
specially at higher
frequencies
Gasinjected foam has
longer lifetime and less
attenuation than other
dielectrics
Phone: +46 410 36 36 10 • Fax: +46 410 36 36 01
3
CU conductor
Copper has
less resistance
than CCS
www.macab.com
TECHNICAL SPECIFICATIONS
Type
RG-59T
Construction
Inner conductor
diameter (mm)
Dielectric
diameter (mm)
Screen 1, type of foil
Foil overlap (mm)
diameter (mm)
Screen 2, type of braid
braid coverage
Screen 3, type of foil
Foil overlap (mm)
Jacket diameter (mm)
Electrical data
Impedance (ohm)
Capacitance (pF/km)
75 ±3
55 ±3
Inner conductor
Loop
DC resistance (ohm/km)
Velocity ratio (%)
Max current (A)
Sheath spark testing (V)
Mechanical data
Min bending radius, single bend (mm)
Max tensile strength (N)
Operational temperature range
PVC
PE
LSNH, UV and water resistant
Installation temperature range
PVC
PE
LSNH, UV and water resistant
Attenuation at 20° C
Loss per 100 m,
max. (dB)
Return loss
RG-6T
RG-11T
Triple shielded, bonded foil
Cu
0,81
1,02
1,63
Gas injected PE
3,66 ±0,1
4,57 ±0,1
7,11 ±0,15
Al-bonded
2
3,84
4,75
7,29
Al
67
60
Al
2
6,2 ±0,3
7,06 ±0,3
10,16 ±0,3
10 MHz
50 MHz
100 MHz
230 MHz
300 MHz
470 MHz
600 MHz
860 MHz
1000 MHz
1450 MHz
1800 MHz
2200 MHz
5–862 MHz, min (dB)
862–2150 MHz, min (dB)
Misc.
Screening efficiency min (dB)
Meter marks
Weight (kg/km)
GRG-Macab AS
Lierstranda 82 NO-3414 Lierstranda, Norway
Phone: +47 32 22 99 90 Fax: +47 32 22 99 91
firmapost@grg-macab.no
35,0
75,0
75 ±2,5
53 ±3
10,0
25,0
85
16,0
23,0
45,0
83
4,0
6,0
4000
25
90
35
120
100
300
–30/+70
–35/+70
–30/+70
–20/+70
–25/70
–20/70
2,7
6,4
8,7
12,9
14,6
18,1
20,5
25,5
26,6
35,0
39,0
43,0
20
18
1,9
5,1
7,0
10,2
11,6
14,7
16,7
20,0
21,5
26,0
28,0
34,0
20
18
1,3
3,1
4,2
6,6
7,4
9,2
10,4
13,4
14,3
22,0
24,0
27,0
20
18
85
yes
32,0
100
yes
43,0
100
yes
67,0
Macab AB
Post: Box 3 SE-231 21 Trelleborg, Sweden
Besök: Vannhögsgatan 7, SE-231 66 Trelleborg
Tel: +46 (0) 410 36 36 10 Fax: +46 (0) 410 36 36 01
info@macab.se
www.macab.com
Max Nordic A/S
Friis Hansensvej 2 DK-7100 Vejle, Denmark
Telefon: +45 31 68 20 10
salg@max-nordic.com
Download