Model PLVX AC-AC Enhanced Precision Displacement Transducer DESCRIPTION Model PLVX displacement transducer is designed for single and steel constructed and windings are magnetically shielded. Ultra multi-point industrial gaging applications and micro-displace- Precision LVDTs utilize spring loaded captive guided armatures ment measurements in research and scientific studies. It incor- and low friction, non-rotating probes. Non-linearity is 0.25 % full porates non-rotating armatures to increase resistance to side scale. The Model PLVX with a 0.02 in stroke range has a me- loads and improve repeatability. Bodies and probes are stainless chanical zero adjustment to correct pre- and over-travel. FEATURES • Miniature design • 0.25 % non-linearity • Rugged, enhanced accuracy • Enhanced immunity to electrical noise • ±0.02 in to ±0.2 in range • -58 °F to 257 °F operating range (standard) • Non-rotating probe • Stainless steel construction • Extended life cycle • Infinite resolution • Captive guided spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model PLVX AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±0,51 mm to 5,08 mm [±0.02 in to 0.20 in] HI ±0,51 mm [±0.02 in] Non-linearity (max.) ±0.25 % full scale HK ±1,02 mm [±0.04 in] Non-repeatability (max.) 6 microinches HM ±2,54 mm [±0.10 in] Output sensitivity See table HN ±5,08 mm [±0.20 in] Output load (min.) 100000 ohm Resolution Infinite Phase shift <10° @ 5 kHz OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±2,54 mm [±0.1 in]; ±0,51 mm [±0.02 in]; ±1,02 mm [±0.04 in]; ±0,25 mm [±0.01 in] Electrical termination Multiconductor shielded cable (1,83 m [6 ft]) Electrical cable orientation Ra. Right angle cable exit Mounting threads TM392. 3/8-32 UNF threaded sleeve Improved linearity L10. ±0.1 % linearity* (only for ±1,02 mm [±0.04]; ±2,54 mm [±0.1]; ±5,08 mm [±0.2 in]) ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 100 °C [-40 °F to 212 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.005 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Multiconductor shielded cable * Air activated model available. Consult factory for details MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Weight See table Spring force (max.) See table 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Enhanced Precision Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L mm [in] N mm [in] D mm [in] X mm [in] Approx. unit weight Max. spring force g [oz] Output sensitivity mV/V/ 0.001 in HI ±0,51[±0.02] 25,9 [1.02] 5,59 [0.22] 8,00 [0.315] 7,62 [0.30] 12,76 [0.45] 99,23 [3.5] 6 HK ±1,02 [±0.04] 53,1 [2.09] 13,97 [0.55] 8,00 [0.315] 13,97 [0.55] 15,88 [0.56] 100,92 [3.56] 4 HM ±2,54 [±0.1] 56,9 [2.24] 18,03 [0.71] 8,00 [0.315] 20,1 [0.79] 17,86 [0.63] 117,93 [4.16] 4 HN ±5,08 [±0.2] 86,6 [3.41]* 29,97 [1.18] 8,00 [0.315] 22,1 [0.87] 22,11 [0.78] 149,97 [5.29] 4* * New L dimension and output sensitivity for 5,08 mm [±0.2 in] range. For old L dimension and output sensitivity, consult factory. WIRING CODES For reference only TYPICAL SYSTEM DIAGRAM Wire color Supply Red (+) supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) 5 Nominal electric zero point Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model PLVX AC-AC Enhanced Precision Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008749-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2,54 mm to 12,7 mm [0.10 in to 0.50 in] Model S5 AC-AC 0,25 mm to 1,02 mm [0.01 in to 0.04 in] Enhanced Precision Displacement Transducer DESCRIPTION Model S5 Ultra Precision displacement transducer is designed probes are stainless steel constructed and windings for single and multi-point industrial gaging applications and are magnetically shielded. Ultra Precision displacement trans- micro-displacement measurements in research and scientific ducers utilize spring loaded captive guided armatures and low studies. It incorporates non-rotating armatures to increase friction, non-rotating probes. Non-linearity is 0.25% full scale. resistance to side loads and improve repeatability. Bodies and FEATURES • Miniature design • 0.25 % non-linearity • Rugged, enhanced accuracy • Enhanced immunity to electrical noise • ±0.01 in to ±0.5 in range • -58 °F to 257 °F operating range (standard) • Non-rotating probe • Stainless steel construction • Extended life cycle • Infinite resolution • Captive guided spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S5 AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±0,25 mm to 12,7 mm [±0.10 in to 0.50 in] HH ±0,25 mm [±0.01 in] Non-linearity (max.) ±0.25 % full scale HI ±0,51 mm [±0.02 in] Non-repeatability <20 microinches HK ±1,02 mm [±0.04 in] Output sensitivity See table HM ±2,54 mm [±0.10 in] Output load (min.) 100000 ohm HN ±5,08 mm [±0.20 in] Resolution Infinite HF ±7,62 mm [±0.30 in] Phase shift <10° @ 5 kHz HG ±10,16 mm [±0.40 in] HP ±12,7 mm [±0.50 in] ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -20 °C to 125 °C [-4 °F to 257 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.006 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Multiconductor shielded cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Weight See table Spring force (max.) See table OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±0,25 mm to 12,7 mm [±0.01 in to ±0.5 in] Electrical termination Multiconductor shielded cable (1,83 m [6 ft]) Electrical cable orientation Ra. Right angle cable exit Mounting threads TM392. 3/8-32 UNF threaded sleeve Improved linearity L10. 0.1 % max. linearity (only for ±0,01 mm to 0,51 mm [±0.040 in to ±0.02 in]) Higher temperature TM315. 204 °C [400 °F] up to 101,6 mm [±4.0 in] 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Enhanced Precision Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range mm [in] L mm [in] D mm [in] X mm [in] Approx. unit weight g [oz] Max. spring force g [oz] Output sensitivity mV/V/ 0.001 in HH ±0,25 [±0.01] 48,01 [1.89] 7,88 [0.31] 10,92 [0.43] 396,89 [14] 212,62 [7.5] 4 HI ±0,51 [±0.02] 48,01 [1.89] 7,88 [0.31] 10,92 [0.43] 396,89 [14] 212,62 [7.5] 4 HK ±1,02 [±0.04] 51,05 [2.01] 7,88 [0.31] 12,95 [0.51] 510,29 [18] 212,62 [7.5] 4 HM ±2,54 [±0.1] 61 [2.40] 9,4 [0.37] 11,43 [0.45] 623,69 [22] 119,92 [4.23] 4 HN ±5,08 [±0.2] 78 [3.07]* 9,4 [0.37] 11,43 [0.45] 737,09 [26] 129,84 [4.58] 4* HF ±7,62 [±0.3] 87,89 [3.46] 9,4 [0.37] 15,24 [0.60] 250,49 [30] 244,94 [8.64] 2 HG ±10,16 [±0.4] 99,06 [3.90] 9,4 [0.37] 19,05 [0.75] 963,88 [34] 209,79 [7.40] 2 HP ±12,7 [±0.5] 120,90 [4.76] 9,4 [0.37] 21,59 [0.85] 1190,68 [42] 214,89 [7.58] 2 * New L dimension and output sensitivity for 5,08 mm [±0.2 in] range. For old L dimension and output sensitivity, consult factory. TYPICAL SYSTEM DIAGRAM Nominal electric zero point Nominal electric zero point For reference only Wire color Supply Red (+) supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) 5 WIRING CODES Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S5 AC-AC Enhanced Precision Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008748-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MVL7 AC-AC Long Stroke Displacement Transducer DESCRIPTION Model MVL7 (free unguided armature) ac-ac long stroke achieves an impressive 0.25 % full scale non-linearities. Dis- displacement transducer is designed for measuring static and placement transducer bodies and probes are constructed of dynamic displacements from ±0.5 in to ±8.0 in. This model stainless steel for durability in harsh, industrial environments. FEATURES • 0.25 % non-linearity • Stainless steel construction • Enhanced immunity to electrical noise • Infinite resolution • 12,7 mm to 203,2 mm [0.5 in to 8.0 in] range • -58 °F to 257 °F operating range (standard) • Free unguided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MVL7 AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 203,2 mm [±0.5 in to 8.0 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] HU ±152,4 mm [±6.0 in] HV ±203,2 mm [±8.0 in] Non-linearity (max.) ±0.25 % full scale Non-repeatability (max.) Not applicable Output sensitivity See table Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 125 °C [-58 °F to 257 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.006 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Multiconductor shielded cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M5 x 0.8 Weight See table Spring force (max.) Not applicable OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 203,2 mm [±0.5 in to 8.0 in] Electrical termination Multiconductor shielded cable (1,83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Higher temperature TM315. 204 °C [400 °F] up to 101,6 mm [±4.0 in] 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. body weight Approx. armature weight Typical full scale output at 3 V RMS HP ±12,7 mm [±0.5 in] 127 mm [5.0 in] 43,18 mm [1.7 in] 170,1 g [6 oz] 35,44 g [1.25 oz] 2.4 V RMS HQ ±25,4 mm [±1.0 in] 152,4 mm [6.0 in] 68,58 mm [2.7 in] 226,8 g [8 oz] 49,61 g [1.75 oz] 3.0 V RMS HR ±50,8 mm [±2.0 in] 269,24 mm [10.6 in] 81,28 mm [3.2 in] 368,54 g [13 oz] 56,7 g [2.0 oz] 4.8 V RMS HS ±76,2 mm [±3.0 in] 381 mm [15.0 in] 119,38 mm [4.7 in] 453,59 g [16 oz] 62,37 g [2.2 oz] 4.5 V RMS HT ±101,6 mm [±4.0 in] 425,45 mm [16.75 in] 132,08 mm [5.2 in] 566,99 g [20 oz] 70,87 g [2.5 oz] 9.5 V RMS HU ±152,4 mm [±6.0 in] 615,95 mm [24.25 in] 182,88 mm [7.2 in] 822,14 g [29 oz] 113,40 g [4.0 oz] 7.2 V RMS HV ±203,2 mm [±8.0 in] 806,45 mm [31.75 in] 259,08 mm [10.2 in] 1190,68 g [42 oz] 144,58 g [5.1 oz] 4.8 V RMS WIRING CODES For reference only Wire color Supply Red (+) supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) 5 TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MVL7 AC-AC Long Stroke Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008752-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model VL7A AC-AC Long Stroke Displacement Transducer DESCRIPTION Model VL7A (spring return armature) ac-ac long stroke displace- impressive 0.25 % full scale non-linearities. Displacement trans- ment transducer is designed for measuring static and dynamic ducer bodies and probes are constructed of stainless steel for displacements from ±0.5 in to ±3.0 in. This model achieve durability in harsh, industrial environments. FEATURES • 0.25 % non-linearity • Stainless steel construction • 12,7 mm to 76,2 mm [0.5 in to 3.0 in] range • Enhanced immunity to electrical noise • Infinite resolution • -58 °F to 257 °F operating range (standard) • Spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model VL7A AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 76,2 mm [±0.5 in to 3.0 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Non-repeatability (max.) <20 microinches HR ±50,8 mm [±2.0 in] Output sensitivity See table HS ±76,2 mm [±3.0 in] Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 125 °C [-58 °F to 257 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.006 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Multiconductor shielded cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread Not applicable Weight See table Spring force (max.) 4 oz/in OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to ±50,8 mm [±0.5 in to ±2.0 in]; 76,2 mm [±3.0 in] Electrical termination Multiconductor shielded cable (1,83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity (less than or equal to 101,6 mm [±4.0 in] Higher temperature TM315. 204 °C [400 °F] up to 101,6 mm [±4.0 in] 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. unit weight Typical full scale output at 3 V RMS HP ±12,7 mm [±0.5 in] 135,89 mm [5.35 in] 38,1 mm [1.5 in] 184,27 g [6.5 oz] 2.4 V RMS HQ ±25,4 mm [±1.0 in] 161,29 mm [6.35 in] 63,5 mm [2.5 in] 226,8 g [8.0 oz] 3.0 V RMS HR ±50,8 mm [±2.0 in] 279,4 mm [11.0 in] 76,2 mm [3.0 in] 396,89 g [14 oz] 4.8 V RMS HS ±76,2 mm [±3.0 in] 389,89 mm [15.35 in] 114,3 mm [4.5 in] 481,94 g [17 oz] 4.5 V RMS WIRING CODES Wire color Supply Red (+) supply (calibrated @ 3 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) For reference only 5 TYPICAL SYSTEM DIAGRAM AA937 Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model VL7A AC-AC Long Stroke Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008751-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MVL7C AC-AC Long Stroke Displacement Transducer DESCRIPTION Model MVL7C (captive guided armature) ac-ac long stroke achieves an impressive 0.25 % full scale non-linearity. Displace- displacement transducer is designed for measuring static and ment transducer bodies and probes are constructed of stainless dynamic displacements from ±0.5 in to ±18.5 in. This model steel for durability in harsh, industrial environments. FEATURES • 0.25 % non-linearity • Stainless steel construction • ±18.5 in long-stroke range available • Enhanced immunity to electrical noise • Infinite resolution • 12,7 mm to 470 mm [0.5 in to 18.5 in] range • -58 °F to 257 °F operating range (standard) • Captive guided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MVL7C AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 470 mm [±0.5 in to 18.5 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±12,5 mm to 254 mm [±0.5 in to ±10 in] ±0.25 % full scale HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] Non-linearity (max.) ±381 mm to 470 mm [±15 in to 18.5 in] ±0.5 % full scale HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] Resolution Infinite HU ±152,4 mm [±6.0 in] HV ±203,2 mm [±8.0 in] HW ±254 mm [±10.0 in] HY ±381 mm [±15.0 in] HZ ±470 mm [±18.5 in] ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 125 °C [-58 °F to 257 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.006 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Multiconductor shielded cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided Probe thread M5 x 0.8 Weight See table Spring force (max.) Not applicable OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 470 mm [±0.5 in to 18.5 in] Electrical termination Multiconductor shielded cable (1,83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Higher temperature TM315. 204 °C [400 °F] up to 101,6 mm [±4.0 in] 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. unit weight Typical full scale output at 3 V RMS HP ±12,7 mm [±0.5 in] 152,4 mm [6.0 in] 38,1 mm [1.5 in] 283,5 g [10 oz] 2.4 V RMS HQ ±25,4 mm [±1.0 in] 177,8 mm [7.0 in] 63,5 mm [2.5 in] 340,19 g [12 oz] 3.0 V RMS HR ±50,8 mm [±2.0 in] 294,64 mm [11.6 in] 76,2 mm [3.0 in] 510,29 g [18 oz] 4.8 V RMS HS ±76,2 mm [±3.0 in] 406,4 mm [16.0 in] 114,3 mm [4.5 in] 652,04 g [23 oz] 4.5 V RMS HT ±101,6 mm [±4.0 in] 452,12 mm [17.8 in] 127,0 mm [5 in] 708,74 g [25 oz] 9.6 V RMS HU ±152,4 mm [±6.0 in] 642,62 mm [25.3 in] 177,8 mm [7 in] 1020,6 g [36 oz] 7.2 V RMS HV ±203,2 mm [±8.0 in] 833,12 mm [32.8 in] 254 mm [10 in] 1417,48 g [50 oz] 4.8 V RMS HW ±254 mm [±10.0 in] 1028,7 mm [40.5 in] 304,8 mm [12 in] 1587,57 g [56 oz] 6.0 V RMS HY ±381 mm [±15.0 in] 1435,1 mm [56.5 in] 406,4 mm [16 in] 2126,21 g [75 oz] 9.0 V RMS HZ ±470 mm [±18.5 in] 1701,8 mm [67.0 in] 508 mm [20 in] 2523,11 g [89 oz] 11.1 V RMS WIRING CODES Wire color Supply Red (+) supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) For reference only 5 TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MVL7C AC-AC Long Stroke Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008753-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC DC-DC Long Stroke Displacement Transducer DESCRIPTION Models JEC (free unguided armature) dc-dc long stroke that sensitivity will remain constant over large variations in sup- displacement transducers utilize an improved internal circuit ply voltage. These models require no further conditioning, thus which incorporates both reverse polarity protection and voltage permitting easy operation. regulation. These features eliminate the danger of permanent damage if supply voltage is accidentally reversed, and ensure FEATURES • Stainless steel construction • Enhanced life cycle • Voltage regulation • Single or dual supply wiring (field selectable) • Reverse polarity protected • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 203,2 mm [±0.5 in to 8.0 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] Non-linearity (max.) ±0.25 % full scale Output load (min.) 2000 ohm with three-wire supply, 20000 ohm with floating supply Output impedance 2 ohm HT ±101,6 mm [±4.0 in] Output sensitivity ±5 Vdc or 0 Vdc to 10 Vdc (field selectable) HU ±152,4 mm [±6.0 in] HV ±203,2 mm [±8.0 in] Isolation 1000 V input to output Polarity Output is positive for outward stroke ENVIRONMENTAL SPECIFICATIONS OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Characteristic Measure Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Stroke ranges ±12,7 mm to 203,2 mm [±0.5 in to 8.0 in] Temperature effect, zero (max.) 0.006 % full scale/°F Electrical termination Temperature effect, span (max.) 0.017 % full scale/°F Multiconductor shielded cable (1.83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Power supply, single 24 Vdc to 40 Vdc @ 30 mA Power supply, dual ±12 Vdc to ±20 Vdc @ 30 mA Ripple power supply 30 mV peak to peak Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) Reverse polarity protection Yes MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M5 x 0.8 Weight See table Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. body weight Approx. armature weight HP ±12,7 mm [±0.5 in] 175,26 mm [6.9 in] 43,18 mm [1.7 in] 212,62 g [7.5 oz] 28,35 g [1.0 oz] HQ ±25,4 mm [±1.0 in] 203,2 mm [8.0 in] 68,58 mm [2.7 in] 269,32 g [9.5 oz] 56,70 g [2.0 oz] HR ±50,8 mm [±2.0 in] 317,5 mm [12.5 in] 81,28 mm [3.2 in] 368,54 g [13.0 oz] 70,87 g [2.5 oz] HS ±76,2 mm [±3.0 in] 429,26 mm [16.9 in] 119,38 mm [4.7 in] 496,12 g [17.5 oz] 85,05 g [3.0 oz] HT ±101,6 mm [±4.0 in] 474,98 mm [18.7 in] 132,08 mm [5.2 in] 623,69 g [22.0 oz] 99,22 g [3.5 oz] HU ±152,4 mm [±6.0 in] 665,48 mm [26.2 in] 182,88 mm [7.2 in] 850,49 g [30.0 oz] 113,40 g [4.0 oz] HV ±203,2 mm [±8.0 in] 855,98 mm [33.7 in] 259,08 mm [10.2 in] 1247,37 g [44.0 oz] 141,75 g [5.0 oz] WIRING CODES Wire color Dual supply Single supply (floating)* Red 12 V to 20 V input 24 V to 40 V input Blue - 12 V to - 20 V input Supply negative Black O V, I/P, O/P common For reference only TYPICAL SYSTEM DIAGRAM Outputs Yellow 0 V to 10 V Green ±5 Vdc * Output common floats at voltage source/2 Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC DC-DC NOTES Long Stroke Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008763-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC-AG DC-DC Long Stroke Displacement Transducer DESCRIPTION Models JEC-AG (captive guided spring return) dc-dc long stroke damage if supply voltage is accidentally reversed, and ensure displacement transducer utilizes an improved internal circuit that sensitivity will remain constant over large variations in sup- which incorporates both reverse polarity protection and voltage ply voltage. These models require no further conditioning, thus regulation. These features eliminate the danger of permanent permitting easy operation. FEATURES • Stainless steel construction • Enhanced life cycle • Voltage regulation • Reverse polarity protected • Single or dual supply wiring (field selectable) • Captive guided spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC-AG DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 76,2 mm [±0.5 in to 3.0 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Output load (min.) 2000 ohm with three-wire supply; 20000 ohm with floating supply HR ±50,8 mm [±2.0 in] Output impedance 2 ohm HS ±76,2 mm [±3.0 in] Output sensitivity ±5 Vdc or 0 Vdc to 10 Vdc (field selectable) Isolation 1000 V input to output Polarity Output positive for outward stroke ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 80 °C [-58 °F to 176 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.017 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Power supply, single 24 Vdc to 40 Vdc @ 30 mA Power supply, dual ±12 Vdc to ±20 Vdc @ 30 mA Ripple 30 mV peak to peak Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) Reverse polarity protection Yes OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm [±0.5 in], ±25,4 mm [±1.0 in], ±50,8 mm [±2.0 in], 6,2 mm [3.0 in] Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread Not applicable Weight See table Spring force (max.) 4 oz/in 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. unit weight HP ±12,7 mm [±0.5 in] 190,5 mm [7.5 in] 38,1 mm [1.5 in] 226,7 g [8 oz] HQ ±25,4 mm [±1.0 in] 209,6 mm [8.25 in] 63,5 mm [2.5 in] 283,5 g [10 oz] HR ±50,8 mm [±2.0 in] 326,39 mm [12.85 in] 76,2 mm [3.0 in] 396,9 g [14 oz] HS ±76,2 mm [±3.0 in] 438,15 mm [17.25 in] 114,3 mm [4.5 in] 510,29 g [18 oz] WIRING CODES For reference only TYPICAL SYSTEM DIAGRAM Wire color Dual supply Single supply (floating)* Red 12 V to 20 V input 24 V to 40 V input Blue -12 V to -20 V input Black OV, I/P, O/P common Outputs Supply negative Yellow 0 V to 10 V Green ±5 Vdc * Output common floats at voltage source/2 Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC-AG DC-DC NOTES Long Stroke Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008762-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC-C DC-DC Long Stroke Displacement Transducer DESCRIPTION Model JEC-C (captive guided armature) dc-dc long stroke dis- if supply voltage is accidentally reversed and ensure that sensi- placement transducer utilizes an improved internal circuit which tivity will remain constant over large variations in supply voltage. incorporates both reverse polarity protection and voltage regula- This model requires no further conditioning, thus permitting easy tion. These features eliminate the danger of permanent damage operation. Stroke ranges from ±0.5 in to ±18.5 in are available. FEATURES • Stainless steel construction • ±18.5 in long-stroke range available • Enhanced life cycle • Voltage regulation • Single or dual supply wiring (field selectable) • Reverse polarity protected • Captive guided • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC-C DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 470 mm [±0.5 in to 18.5 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] HU ±152,4 mm [±6.0 in] HV ±203,2 mm [±8.0 in] HW ±254 mm [±10.0 in] HY ±381 mm [±15.0 in] HZ ±470 mm [±18.5 in] Non-linearity (max.) ±12,5 mm to 254 mm [±0.5 in to ±10 in] ±0.25 % full scale ±381 mm to 470 mm [±15 in to 18.5 in] ±0.5 % full scale Output load (min.) 2000 ohm with three-wire supply; 20000 ohm with floating supply Output impedance 2 ohm Output sensitivity ±5 Vdc or 0 Vdc to 10 Vdc (field selectable) Isolation 1000 V input to output Polarity Output positive for outward stroke OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 470 mm [±0.5 in to 18.5 in] Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.017 % full scale/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Power supply, single 24 Vdc to 40 Vdc @ 30 mA Power supply, dual ±12 Vdc to ±20 Vdc @ 30 mA Ripple 30 mV peak to peak Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) Reverse polarity protection Yes MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided Probe thread M5 x 0.8 Weight See table Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. unit weight HP ±12,7 mm [±0.5 in] 190,5 mm [7.5 in] 38,1 mm [1.5 in] 340,9 g [12 oz] HQ ±25,4 mm [±1.0 in] 219,15 mm [8.5 in] 63,5 mm [2.5 in] 396,9 g [14 oz] HR ±50,8 mm [±2.0 in] 332,74 mm [13.1 in] 76,2 mm [3.0 in] 510,29 g [18 oz] HS ±76,2 mm [±3.0 in] 444,5 mm [17.5 in] 114,3 mm [4.5 in] 623,6 g [22 oz] HT ±101,6 mm [±4.0 in] 490,22 mm [19.3 in] 127 mm [5.0 in] 765,4 g [27 oz] HU ±152,4 mm [±6.0 in] 680,72 mm [26.8 in] 177,8 mm [7.0 in] 1020,5 g [36 oz] HV ±203,2 mm [±8.0 in] 871,22 mm [34.3 in] 254 mm [10 in] 1445 g [51.0 oz] HW ±254 mm [±10.0 in] 1066,8 mm [42.0 in] 304,8 mm [12 in] 1672 g [59.0 oz] HY ±381 mm [±15.0 in] 1473,2 mm [58.0 in] 406,4 mm [16 in] 2211 g [78.0 oz] HZ ±470 mm [±18.5 in] 1740 mm [68.5 in] 508 mm [20 in] 2608 g [92.0 oz] WIRING CODES Wire color Dual supply Single supply (floating)* Red 12 V to 20 V input 24 V to 40 V input Blue -12 V to -20 V input Supply negative Black OV, I/P, O/P common For reference only TYPICAL SYSTEM DIAGRAM Outputs Yellow 0 V to 10 V Green ±5 Vdc * Output common floats at voltage source/2 Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model JEC-C DC-DC NOTES Long Stroke Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008764-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLB DC-DC Long Stroke Displacement Transducer DESCRIPTION Model DLB (free unguided) displacement transducer operates digital panel meters to from a complete readout system. The from either 5 Vdc regulated or 6 Vdc to 18 Vdc unregulated DLB, free unguided is available with stroke ranges of ±0.5 in to and generates an output signal of ±2 Vdc. The output signal is ±8.0 in. electrically isolated from the input voltage and can be used with FEATURES • ±0.25 % non-linearity • ±12,7 mm to ±203,2 mm [±0.5 in to ±8 in] • Low voltage requirements • Easy to operate • Stainless steel construction • Reverse polarity protected • Single or dual supply wiring (field selectable) • Infinite resolution • Free unguided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLB DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 203,2 mm [±0.5 in to 8.0 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] HU ±152,4 mm [±6.0 in] HV ±203,2 mm [±8.0 in] Non-linearity (max.) ±0.25 % full scale Output load (min.) 2000 ohm Output impedance 2 ohm Output sensitivity ±2 Vdc (nominal) Isolation 1000 V input to output Polarity Output positive for outward stroke ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.017 % full scale/°F ELECTRICAL SPECIFICATIONS OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 203,2 mm [±0.5 in to 8.0 in] Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Characteristic Measure Element type dc-dc displacement transducer 5 Vdc @ 100 mA max. Mounting threads TM511. 13/16-32 UNF Input supply (acceptable), regulated Input supply (acceptable), unregulated 6 V to 18 Vdc @ 100 mA max. Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Ripple 30 mV peak to peak Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) Reverse polarity protection Yes MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M5 x 0.8 Weight See table Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. body weight Approx. armature weight HP ±12,7 mm [±0.5 in] 175,26 mm [6.9 in] 43,18 mm [1.7 in] 212,62 g [7.5 oz] 28,35 g [1.0 oz] HQ ±25,4 mm [±1.0 in] 200,6 mm [7.9 in] 68,58 mm [2.7 in] 269,32 g [9.5 oz] 56,70 g [2.0 oz] HR ±50,8 mm [±2.0 in] 317,5 mm [12.5 in] 81,28 mm [3.2 in] 368,54 g [13.0 oz] 70,87 g [2.5 oz] HS ±76,2 mm [±3.0 in] 429,26 mm [16.9 in] 119,38 mm [4.7 in] 496,12 g [17.5 oz] 85,05 g [3.0 oz] HT ±101,6 mm [±4.0 in] 472,44 mm [18.6 in] 132,08 mm [5.2 in] 623,69 g [22.0 oz] 99,22 g [3.5 oz] HU ±152,4 mm [±6.0 in] 662,94 mm [26.1 in] 182,88 mm [7.2 in] 850,49 g [30.0 oz] 113,40 g [4.0 oz] HV ±203,2 mm [±8.0 in] 853,44 mm [33.6 in] 259,08 mm [10.2 in] 1247,37 g [44.0 oz] 141,75 g [5.0 oz] WIRING CODES For reference only TYPICAL SYSTEM DIAGRAM Wire color 5 V supply 6 Vdc to 18 Vdc supply Yellow 5 V input Connect to brown Brown Insulate Connect to yellow Red Insulate 6 Vdc to 18 Vdc Blue Supply common (0 V) Supply common (0 V) Black Output low Output low Green Output high Output high Shield Instrument ground Instrument ground Note: Incorrect connection may cause irreparable damage, consult factory for assistance. Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLB DC-DC NOTES Long Stroke Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008760-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLE DC-DC Long Stroke Displacement Transducer DESCRIPTION Model DLE (captive guided armature) operates from either 5 from the input voltage and can be used with digital panel meters Vdc regulated or 6 Vdc to 18 Vdc unregulated and generate an to from a complete readout system. The DLE, captive guided output signal of ±2 Vdc. The output signal is electrically isolated armature has stroke ranges of ±0.5 in to ±18.5 in. FEATURES • ±0.25 % non-linearity • ±12,7 mm to 470 mm [±0.5 in to 18.5 in] range • Low voltage requirements • Easy to operate • Stainless steel construction • Reverse polarity protected • Single or dual supply wiring (field selectable) • Infinite resolution • Captive guided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLE DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 470 mm [±0.5 in to 18.5 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±12,5 mm to 254 mm [±0.5 in to ±10 in] ±0.25 % full scale HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] Non-linearity (max.) ±381 mm to 470 mm [±15 in to 18.5 in] ±0.5 % full scale HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] Output load (min.) 2000 ohm HU ±152,4 mm [±6.0 in] Output impedance 2 ohm HV ±203,2 mm [±8.0 in] Output sensitivity ±2 Vdc (nominal) HW ±254 mm [±10.0 in] Isolation 1000 V input to output HY ±381 mm [±15.0 in] Polarity Output positive for outward stroke HZ ±470 mm [±18.5 in] ENVIRONMENTAL SPECIFICATIONS OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. 0.006 % full scale/°F Stroke ranges ±12,7 mm to 470 mm [±0.5 in to 18.5 in] 0.017 % full scale/°F Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Characteristic Measure Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Temperature effect, zero (max.) Temperature effect, span (max.) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Input supply (acceptable), regulated 5 Vdc @ 100 mA max. Input supply (acceptable), unregulated 6 Vdc to 18 Vdc @ 100 mA max. Ripple 30 mV peak to peak Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) Reverse polarity protection Yes MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided Probe thread M5 x 0.8 Weight See table Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. unit weight HP ±12,7 mm [±0.5 in] 190,5 mm [7.5 in] 38,1 mm [1.5 in] 340,9 g [12 oz] HQ ±25,4 mm [±1.0 in] 215,9 mm [8.5 in] 63,5 mm [2.5 in] 396,9 g [14 oz] HR ±50,8 mm [±2.0 in] 332,74 mm [13.1 in] 76,2 mm [3.0 in] 510,29 g [18 oz] HS ±76,2 mm [±3.0 in] 444,5 mm [17.5 in] 114,3 mm [4.5 in] 623,6 g [22 oz] HT ±101,6 mm [±4.0 in] 490,22 mm [19.3 in] 127 mm [5.0 in] 765,4 g [27 oz] HU ±152,4 mm [±6.0 in] 680,72 mm [26.8 in] 177,8 mm [7.0 in] 1020,5 g [36 oz] HV ±203,2 mm [±8.0 in] 871,22 mm [34.3 in] 254 mm [10 in] 1445 g [51 oz] HW ±254 mm [±10.0 in] 1066,8 mm [42.0 in] 304,8 mm [12 in] 1672 g [59 oz] HY ±381 mm [±15.0 in] 1473,2 mm [58.0 in] 406,4 mm [16 in] 2211 g [78 oz] HZ ±470 mm [±18.5 in] 1740 mm [68.5 in] 508 mm [20 in] 2608 g [92 oz] WIRING CODES For reference only TYPICAL SYSTEM DIAGRAM Wire color 5 V supply 6 Vdc to 18 Vdc supply Yellow 5 V input Connect to brown Brown Insulate Connect to yellow Red Insulate 6 Vdc to 18 Vdc Blue Supply common (0 V) Supply common (0 V) Black Output low Output low Green Output high Output high Shield Instrument ground Instrument ground Note: Incorrect connection may cause irreparable damage, consult factory for assistance. Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLE DC-DC NOTES Long Stroke Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008761-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLF DC-DC Long Stroke Displacement Transducer DESCRIPTION Model DLF (captive guided spring return) operates from either 5 from the input voltage and can be used with digital panel meters Vdc regulated or 6 Vdc to 18 Vdc unregulated and generate an to from a complete readout system. The DLF, captive guided output signal of ±2 Vdc. The output signal is electrically isolated spring return, from 0.5 in to 3.0 in. FEATURES • ±0.25 % non-linearity • ±12,7 mm to 76,2 mm [±0.5 in to 3.0 in] range • Low voltage requirements • Easy to operate • Stainless steel construction • Reverse polarity protected • Single or dual supply wiring (field selectable) • Infinite resolution • Captive guided spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLF DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 76,2 mm [±0.5 in to 3 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Output load (min.) 2000 ohm HR ±50,8 mm [±2.0 in] Output impedance 2 ohm HS ±76,2 mm [±3.0 in] Output sensitivity ±2 Vdc (nominal) Isolation 1000 V input to output Polarity Output positive for outward stroke OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Stroke ranges ±12,7 mm to 76,2 mm [±0.5 in to 3 in] Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Electrical termination Temperature effect, span (max.) 0.017 % full scale/°F Multiconductor shielded cable (1.83 m [6 ft]) TM405. Axial Bendix connector on body radial (side) TM406. Bendix connector on body Electrical cable orientation TM49. Axial cable exit Mounting threads TM511. 13/16-32 UNF Improved linearity L10. ±0.1 % max. linearity ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Input supply (acceptable), regulated 5 Vdc @ 100 mA max. Input supply (acceptable), unregulated 6 Vdc to 18 Vdc @ 100 mA max. Ripple 30 mV peak to peak Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) Reverse polarity protection Yes MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread N/A Weight See table Spring force (max.) 4.0 oz/in 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Long Stroke Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Approx. unit weight HP ±12,7 mm [±0.5 in] 184,15 mm [7.25 in] 38,1 mm [1.5 in] 226,7 g [8 oz] HQ ±25,4 mm [±1.0 in] 209,6 mm [8.25 in] 63,5 mm [2.5 in] 283,5 g [10 oz] HR ±50,8 mm [±2.0 in] 326,39 mm [12.85 in] 76,2 mm [3.0 in] 396,9 g [14 oz] HS ±76,2 mm [±3.0 in] 438,15 mm [17.25 in] 114,3 mm [4.5 in] 510,29 g [18 oz] WIRING CODES For reference only TYPICAL SYSTEM DIAGRAM Wire color 5 V supply 6 Vdc to 18 Vdc supply Yellow 5 V input Connect to brown Brown Insulate Connect to yellow Red Insulate 6 Vdc to 18 Vdc Blue Supply common (0 V) Supply common (0 V) Black Output low Output low Green Output high Output high Shield Instrument ground Instrument ground Note: Incorrect connection may cause irreparable damage, consult factory for assistance. Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DLF DC-DC NOTES Long Stroke Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008759-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7S AC-AC Submersible* Displacement Transducer DESCRIPTION Model LW7S submersible displacement transducer is often ideal ing linear displacement device or positional feedback element for drilling, mining, and hydraulic engineering applications which in dynamic systems. They are suitable for submersion in fresh require a displacement transducer with a stainless steel, water- water and some corrosive fluids for long periods. proof construction. This model may be used as direct measur- FEATURES • ±0.25 % non-linearity • Submersible • Stainless steel construction • ±12,7 mm to 76,2 mm range [±0.5 in to ±3.0 in range] • Enhanced immunity to electrical noise • Submersible mating connector with 5 m {16 ft] cable • Easy to operate • Captive guided spring return armature • Infinite resolution • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7S AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 76,2 mm [±0.5 in to 3.0 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Non-repeatability (max.) <20 microinches HR ±50,8 mm [±2.0 in] Output sensitivity See table HS ±76,2 mm [±3.0 in] Resolution Infinite ENVIRONMENTAL SPECIFICATIONS OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Characteristic Measure Temperature, operating -40 °C to 90 °C [-40 °F to 194 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Stroke ranges ±12,7 mm to 76,2 mm [±0.5 in to 3 in] Temperature effect, span (max.) 0.005 % full scale/°F Electrical termination Pressure rating, standard 150 psi, up to 3000 psi with cable options Multiconductor shielded cable (1.83 m [6.0 ft]) OPT1. No connector or cable, terminated with soldier pins OPT5. Mineral insulated welded stainless steel sheathed cable (3 mm [0.12 in] dia. cable, 50 m [1 ft to 164 ft] lengths available, -55 °C to 200 °C [-67 °F to 390 °F], 200 bar [3000 psi] Electrical cable orientation OPT7. Radial output submersible connector with 5.03 m [16.5 ft] cable Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Higher temperature TM315. 204 °C [400 °F] (less than or equal to ±101.6 mm [±4 in]) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 5 kHz Output load (minimum) 100000 ohm Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread Not applicable Spring force (max.) 4 oz/in 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Spring force oz/in Typical full scale output at 5 V RMS HP ±12,7 mm [±0.5 in] 152,90 mm [6.02 in] 38,1 mm [1.5 in] 4 3.5 V RMS HQ ±25,4 mm [±1.0 in] 180,85 mm [7.12 in] 63,5 mm [2.5 in] 4 4.5 V RMS HR ±50,8 mm [±2.0 in] 304,04 mm [11.97 in] 76,2 mm [3.0 in] 4 7.6 V RMS HS ±76,2 mm [±3.0 in] 419,86 mm [16.53 in] 114,3 mm [4.5 in] 4 7.5 V RMS WIRING CODES Wire color Dual power supply Brown Supply White Supply return Blue Output Black Output return For reference only 5 TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7S AC-AC NOTES Submersible* Displacement Transducer * Not recommended for salt water use. Consult factory for saltwater submersible applications. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008743-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7C AC-AC Submersible* Displacement Transducer DESCRIPTION Model LW7C submersible displacement transducer is often ideal linear displacement device or positional feedback element in dy- for drilling, mining, and hydraulic engineering applications which namic systems. They are suitable for submersion in fresh water require a displacement transducer with a stainless steel, water- and some corrosive fluids for long periods. The captive guided proof construction. This model may be used as direct measuring spring return armature is fitted with a ball ended probe. FEATURES • ±0.25 % non-linearity • Submersible • Stainless steel construction • ±12,7 mm to 101,6 mm range [±0.5 in to ±4.0 in range] • Enhanced immunity to electrical noise • Submersible mating connector with 5 m {16 ft] cable • Easy to operate • Captive guided armature • Infinite resolution • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7C AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 101,6 mm [±0.5 in to 4.0 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] Non-linearity (max.) ±0.25 % full scale Output sensitivity See table Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 90 °C [-40 °F to 194 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.005 % full scale/°F Pressure rating, standard 150 psi, up to 3000 psi with cable options OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 101,6 mm [±0.5 in to 4 in] Electrical termination Multiconductor shielded cable (1.83 m [6.0 ft]) OPT1. No connector or cable, terminated with soldier pins OPT5. Mineral insulated welded stainless steel sheathed cable (3 mm [0.12 in] dia. cable, 50 m [1 ft to 164 ft] lengths available, -55 °C to 200 °C [-67 °F to 390 °F], 200 bar [3000 psi] Electrical cable orientation OPT7. Radial output submersible connector with 5.03 m [16.5 ft] cable Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Higher temperature TM315. 204 °C [400 °F] (less than or equal to ±101.6 mm [±4 in]) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 5 kHz Output load (minimum) 100000 ohm Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided Probe thread M5 x 0.8 Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Weight armature Typical full scale output at 5 V RMS HP ±12,7 mm [±0.5 in] 152,90 mm [6.02 in] 38,1 mm [1.5 in] 21,26 g [0.75 oz] 3.5 V RMS HQ ±25,4 mm [±1.0 in] 180,85 mm [7.12 in] 63,5 mm [2.5 in] 28,35 g [1.0 oz] 4.5 V RMS HR ±50,8 mm [±2.0 in] 304,04 mm [11.97 in] 76,2 mm [3.0 in] 42,52 g [1.5 oz] 7.6 V RMS HS ±76,2 mm [±3.0 in] 419,86 mm [16.53 in] 114,3 mm [4.5 in] 85,05 g [3.0 oz] 7.5 V RMS HT ±101,6 mm [±4.0 in] 452,88 mm [17.83 in] 127 mm [5.0 in] 104,89 g [3.7 oz] 16.05 V RMS WIRING CODES Wire color Dual power supply Brown Supply White Supply return Blue Output Black Output return For reference only 5 TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7C AC-AC NOTES Submersible* Displacement Transducer * Not recommended for salt water use. Consult factory for saltwater submersible applications. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008744-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7U AC-AC Submersible* Displacement Transducer DESCRIPTION Model LW7U submersible displacement transducer is often ideal ing linear displacement device or positional feedback element for drilling, mining, and hydraulic engineering applications which in dynamic systems. They are suitable for submersion in fresh require a displacement transducer with a stainless steel, water- water and some corrosive fluids for long periods. proof construction. This model may be used as direct measur- FEATURES • ±0.25 % non-linearity • Submersible • Stainless steel construction • ±12,7 mm to 101,6 mm range [±0.5 in to ±4.0 in range] • Enhanced immunity to electrical noise • Submersible mating connector with 5 m {16 ft] cable • Easy to operate • Free unguided armature • Infinite resolution • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7U AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 101,6 mm [±0.5 in to 4.0 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] Non-linearity (max.) ±0.25 % full scale Output sensitivity See table Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 90 °C [-40 °F to 194 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.005 % full scale/°F Pressure rating, standard 150 psi, up to 3000 psi with cable options OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 101,6 mm [±0.5 in to 4 in] Electrical termination Submersible mating connector with 1.83 m [6.0 ft] cable OPT1. No connector or cable,terminated with soldier pins OPT5. Mineral insulated welded stainless steel sheathed cable (3 mm [0.12 in] dia. cable, 50 m [1 ft to 164 ft] lengths available, -55 °C to 200 °C [-67 °F to 390 °F], 200 bar [3000 psi] Electrical cable orientation OPT7. Radial output submersible connector with 5.03 m [16.5 ft] cable Improved linearity L10. ±0.1 % max. linearity (less than or equal to ±101.6 mm [±4 in]) Higher temperature TM315. 204 °C [400 °F] (less than or equal to ±101.6 mm [±4 in]) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 5 kHz Output load (minimum) 100000 ohm Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M5 x 0.8 Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Weight armature Typical full scale output at 5 V RMS HP ±12,7 mm [±0.5 in] 152,90 mm [6.02 in] 38,1 mm [1.5 in] 21,26 g [0.75 oz] 3.5 V RMS HQ ±25,4 mm [±1.0 in] 180,85 mm [7.12 in] 63,5 mm [2.5 in] 28,35 g [1.0 oz] 4.5 V RMS HR ±50,8 mm [±2.0 in] 304,04 mm [11.97 in] 76,2 mm [3.0 in] 42,52 g [1.5 oz] 7.6 V RMS HS ±76,2 mm [±3.0 in] 419,86 mm [16.53 in] 114,3 mm [4.5 in] 85,05 g [3.0 oz] 7.5 V RMS HT ±101,6 mm [±4.0 in] 452,88 mm [17.83 in] 127 mm [5.0 in] 104,89 g [3.7 oz] 16.05 V RMS WIRING CODES [0.06 in] For reference only Wire color Dual power supply Brown Supply White Supply return Blue Output Black Output return 5 TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model LW7U AC-AC NOTES Submersible* Displacement Transducer * Not recommended for salt water use. Consult factory for saltwater submersible applications. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008745-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7S DC-DC Submersible* Displacement Transducer DESCRIPTION Model DW7S submersible displacement transducer is often ideal linear displacement devices or positional feedback elements for drilling, mining, and hydraulic engineering applications which in dynamic systems. They are suitable for submersion in fresh require a displacement transducer with a stainless steel, water- water and some corrosive fluids for long periods. The captive proof construction. This model may be used as direct measuring guided spring return armature is fitted with a ball-ended probe. FEATURES • ±0.25 % non-linearity • Submersible • Stainless steel construction • Easy to operate • 5 m [16 ft] submersible mating connector (standard) • ±12,7 mm to 76,2 mm range [±0.5 in to ±3.0 in range] • Infinite resolution • Single or dual supply wiring (field selectable) • Reverse polarity protected • Captive guided spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7S DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 76,2 mm [±0.5 in to 3 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Non-repeatability (max.) <20 microinches HR ±50,8 mm [±2.0 in] Output sensitivity See table HS ±76,2 mm [±3.0 in] ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 70 °C [-40 °F to 158 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.015 % full scale/°F Pressure rating, standard 150 psi, up to 3000 psi with cable options OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 76,2 mm [±0.5 in to 3 in] Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable OPT1. No connector or cable, terminated with soldier pins OPT5. Mineral insulated welded stainless steel sheathed cable (3 mm [0.12 in] dia. cable, 50 m [1 ft to 164 ft] lengths available, -55 °C to 200 °C [-67 °F to 390 °F], 200 bar [3000 psi] Electrical cable orientation OPT7. Radial output submersible connector with 5.03 m [16.5 ft] cable Improved linearity L10. ±0.1 % max. linearity ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Input supply (acceptable) ±10 Vdc to 20 Vdc unregulated (45 mA max.) or 20 Vdc to 40 Vdc unregulated (45 mA max.) Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread Not applicable Spring force (max.) 4 oz/in 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Spring force (oz/in) Typical full scale output HP ±12,7 mm [±0.5 in] 203,2 mm [8.00 in] 38,1 mm [1.5 in] 4 ±5 Vdc HQ ±25,4 mm [±1.0 in] 231,14 mm [9.10 in] 63,5 mm [2.5 in] 4 ±5 Vdc HR ±50,8 mm [±2.0 in] 354,33 mm [13.95 in] 76,2 mm [3.0 in] 4 ±5 Vdc HS ±76,2 mm [±3.0 in] 470,41 mm [18.52 in] 114,3 mm [4.5 in] 4 ±5 Vdc WIRING CODES Wire color Dual power supply Brown (+) supply, 10 Vdc to 20 Vdc Blue (-) supply, -10 Vdc to -20 Vdc Black (-) output common/supply return White (+) output, ±5 Vdc (min. 2k ohm across black and white) For reference only Reverse polarity protected with voltage regulator. Cable shield is not connected to transducer. TYPICAL SYSTEM DIAGRAM DC input GM-A Wire color Single power supply Brown (+) supply, 20 Vdc to 40 Vdc Blue Supply return Black (-) output White (+) output, ±5 Vdc (min. 20k ohm across black and white) Reverse polarity protected with voltage regulator. Cable shield is not connected to transducer. Either black or blue must float. If both are grounded or connected together, the unit will be destroyed. Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7S DC-DC NOTES Submersible* Displacement Transducer * Not recommended for salt water use. Consult factory for saltwater submersible applications. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008754-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7C DC-DC Submersible* Displacement Transducer DESCRIPTION Model DW7C submersible displacement transducer is often measuring linear displacement devices or positional feedback ideal for drilling, mining, and hydraulic engineering applica- elements in dynamic systems. They are suitable for submersion tions which require a displacement transducer with a stainless in fresh water and some corrosive fluids for long periods. steel, waterproof construction. This model may be used as direct FEATURES • ±0.25 % non-linearity • Submersible • Stainless steel construction • Easy to operate • 5 m [16 ft] submersible mating connector (standard) • ±12,7 mm to 101,6 mm range [±0.5 in to ±4.0 in range] • Infinite resolution • Single or dual supply wiring (field selectable) • Reverse polarity protected • Captive guided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7C DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Measure Range Code Available ranges Stroke range ±12,7 mm to 101,6 mm [±0.5 in to 4 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Output sensitivity See table HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] Characteristic ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 70 °C [-40 °F to 158 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.015 % full scale/°F Pressure rating, standard 150 psi, up to 3000 psi with cable options OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 101,6 mm [±0.5 in to 4 in] Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable OPT1. No connector or cable, terminated with soldier pins OPT5. Mineral insulated welded stainless steel sheathed cable (3 mm [0.12 in] dia. cable, 50 m [1 ft to 164 ft] lengths available, -55 °C to 200 °C [-67 °F to 390 °F], 200 bar [3000 psi] Electrical cable orientation OPT7. Radial output submersible connector with 5.03 m [16.5 ft] cable Improved linearity L10. ±0.1 % max. linearity (less than or equal to 101,6 mm [±4.0 in] ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Input supply (acceptable) ±10 Vdc to 20 Vdc unregulated (45 mA max.) or 20 Vdc to 40 Vdc unregulated (45 mA max.) Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided Probe thread M5 x 0.8 in Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Weight armature Typical full scale output HP ±12,7 mm [±0.5 in] 203,2 mm [8.00 in] 38,1 mm [1.5 in] 21,26 g [0.75 oz] ±5 Vdc HQ ±25,4 mm [±1.0 in] 231,14 mm [9.10 in] 63,5 mm [2.5 in] 28,35 g [1.0 oz] ±5 Vdc HR ±50,8 mm [±2.0 in] 354,33 mm [13.95 in] 76,2 mm [3.0 in] 42,52 g [1.5 oz] ±5 Vdc HS ±76,2 mm [±3.0 in] 470,41 mm [18.52 in] 114,3 mm [4.5 in] 85,05 g [3.0 oz] ±5 Vdc HT ±101,6 mm [±4.0 in] 502,92 mm [19.80 in] 127,0 mm [5 in] 104,89 g [3.7 oz] ±5 Vdc WIRING CODES For reference only Wire color Dual power supply Brown (+) supply, 10 Vdc to 20 Vdc Blue (-) supply, -10 Vdc to -20 Vdc Black (-) output common/supply return White (+) output, ±5 Vdc (min. 2k ohm across black and white) Reverse polarity protected with voltage regulator. Cable shield is not connected to transducer. TYPICAL SYSTEM DIAGRAM DC input GM-A Wire color Single power supply Brown (+) supply, 20 Vdc to 40 Vdc Blue Supply return Black (-) output White (+) output, ±5 Vdc (min. 20k ohm across black and white) Reverse polarity protected with voltage regulator. Cable shield is not connected to transducer. Either black or blue must float. If both are grounded or connected together, the unit will be destroyed. Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7C DC-DC NOTES Submersible* Displacement Transducer * Not recommended for salt water use. Consult factory for saltwater submersible applications. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008756-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7U DC-DC Submersible* Displacement Transducer DESCRIPTION Model DW7U submersible displacement transducer is often measuring linear displacement devices or positional feedback ideal for drilling, mining, and hydraulic engineering applica- elements in dynamic systems. They are suitable for submersion tions which require a displacement transducer with a stainless in fresh water and some corrosive fluids for long periods. steel, waterproof construction. This model may be used as direct FEATURES • ±0.25 % non-linearity • Submersible • Stainless steel construction • Easy to operate • 5 m [16 ft] submersible mating connector (standard) • ±12,7 mm to 101,6 mm range [±0.5 in to ±4.0 in range] • Infinite resolution • Single or dual supply wiring (field selectable) • Reverse polarity protected • Free unguided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7U DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 101,6 mm [±0.5 in to 4 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±0.25 % full scale HQ ±25,4 mm [±1.0 in] Output sensitivity See table HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 70 °C [-40 °F to 158 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.015 % full scale/°F Pressure rating, standard 150 psi, up to 3000 psi with cable options OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 101,6 mm [±0.5 in to 4 in] Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable OPT1. No connector or cable, terminated with soldier pins OPT5. Mineral insulated welded stainless steel sheathed cable (3 mm [0.12 in] dia. cable, 50 m [1 ft to 164 ft] lengths available, -55 °C to 200 °C [-67 °F to 390 °F], 200 bar [3000 psi] Electrical cable orientation OPT7. Radial output submersible connector with 5.03 m [16.5 ft] cable Improved linearity L10. ±0.1 % max. linearity (less than or equal to 101,6 mm [±4.0 in] ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Input supply (acceptable) ±10 Vdc to 20 Vdc unregulated (45 mA max.) or 20 Vdc to 40 Vdc unregulated (45 mA max.) Electrical termination Submersible mating connector with 5.03 m [16.5 ft] cable MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M5 x 0.8 in Spring force (max.) Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X Weight armature Typical full scale output HP ±12,7 mm [±0.5 in] 203,2 mm [8.00 in] 38,1 mm [1.5 in] 21,26 g [0.75 oz] ±5 Vdc HQ ±25,4 mm [±1.0 in] 231,14 mm [9.10 in] 63,5 mm [2.5 in] 28,35 g [1.0 oz] ±5 Vdc HR ±50,8 mm [±2.0 in] 354,33 mm [13.95 in] 76,2 mm [3.0 in] 42,52 g [1.5 oz] ±5 Vdc HS ±76,2 mm [±3.0 in] 470,41 mm [18.52 in] 114,3 mm [4.5 in] 85,05 g [3.0 oz] ±5 Vdc HT ±101,6 mm [±4.0 in] 502,92 mm [19.80 in] 127,0 mm [5 in] 104,89 g [3.7 oz] ±5 Vdc WIRING CODES Wire color Dual power supply Brown (+) supply, 10 Vdc to 20 Vdc Blue (-) supply, -10 Vdc to -20 Vdc Black (-) output common/supply return White (+) output, ±5 Vdc (min. 2k ohm across black and white) For reference only Reverse polarity protected with voltage regulator. Cable shield is not connected to transducer. TYPICAL SYSTEM DIAGRAM DC input GM-A Wire color Single power supply Brown (+) supply, 20 Vdc to 40 Vdc Blue Supply return Black (-) output White (+) output, ±5 Vdc (min. 20k ohm across black and white) Reverse polarity protected with voltage regulator. Cable shield is not connected to transducer. Either black or blue must float. If both are grounded or connected together, the unit will be destroyed. Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model DW7U DC-DC NOTES Submersible* Displacement Transducer * Not recommended for salt water use. Consult factory for saltwater submersible applications. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008755-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MS7A AC-AC Submersible* Displacement Transducer DESCRIPTION Model MS7A submersible displacement transducer is en- cables and a waterproof outer jacket are hermetically sealed to gineered for rugged industrial applications which require a the transducer to allow for submersion in most liquids and cor- waterproof transducer. This stainless steel unit is designed with rosive fluids. These models can withstand external pressures to permanently attached, waterproof connecting cable. Connecting 250 psi. FEATURES • ±0.25 % non-linearity • Submersible • Withstands 250 psi, external pressure • Stainless steel construction • ±1,02 mm to 12,7 mm [±0.04 to ± 0.50 in range] • -4 °F to 257 °F operating range (standard) • Enhanced immunity to electrical noise • Captive guided spring return armature • Hermetically sealed, waterproof cable 1.83 m [6 ft] • Easy to operate • Infinite resolution • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MS7A AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±1,02 mm to 12,7 mm [±0.04 in to 0.50 in] HK ±1,02 mm [±0.04 in] HM ±2,54 mm [±0.10 in] HN ±5,08 mm [±0.20 in] HF ±7,62 mm [±0.30 in] HG ±10,16 mm [±0.40 in] HP ±12,7 mm [±0.50 in] Non-linearity (max.) ±0.25 % full scale Non-repeatability <10 microinches Output sensitivity 2 mV/V/ 0.001 in Output load 100000 ohm Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -20 °C to 125 °C [-4 °F to 257 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.006 % full scale/°F OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±1,02 mm to 12,7 mm [±0.04 in to ±0.5 in] Electrical termination Hermetically sealed waterproof cable (1,83 m [6 ft]) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Hermetically sealed waterproof cable 1.83 m [6ft] MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M3 X 0.5 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range mm [in] L mm [in] D mm [in] X ** mm [in] D1 mm [in] Total weight*** g [oz] Armature weight g [oz] HK ±1,02 [±0.04] 40,89 [1.61] 8,00 [0.315] 16,99 [0.669] 2,34 [0.092] 25,51 [0.90] 3,69 [0.13] HM ±2,54 [±0.1] 46,99 [1.85] 9,53 [0.375] 17,98 [0.708] 2,34 [0.092] 28,35 [1.00] 5,67 [0.20] HN ±5,08 [±0.2] 50,29 [1.98] 9,53 [0.375] 22,86 [0.900] 2,34 [0.092] 32,60 [1.15] 7,09 [0.25] HF ±7,62 [±0.3] 69,85 [2.75] 9,53 [0.375] 29,21 [1.150] 2,34 [0.092] 45,35 [1.60] 9,92 [0.35] HG ±10,16 [±0.4] 73,91 [2.91] 9,53 [0.375] 32,51 [1.280] 2,34 [0.092] 48,19 [1.70] 10,49 [0.37] HP ±12,7 [±0.5] 89,91 [3.54] 9,53 [0.375] 34,93 [1.375] 2,34 [0.092] 59,53 [2.10] 12,76 [0.45] WIRING CODES TYPICAL SYSTEM DIAGRAM Supply Supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) Cable shield is not connected to transducer 5 For reference only Wire color Red Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MS7A AC-AC NOTES * Not recommended for salt water use ** Dimensions at “X” at nominal electrical zero *** Excluding cable Submersible* Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008742-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S7C AC-AC Submersible* Displacement Transducer DESCRIPTION Model S7C ac-ac submersible displacement transducer is cables and a waterproof outer jacket are hermetically sealed to engineered for rugged industrial applications which require a the transducer to allow for submersion in most liquids and cor- waterproof transducer. This stainless steel unit is designed with rosive fluids. These models can withstand external pressures to permanently attached, waterproof connecting cable. Connecting 250 psi. FEATURES • ±0.25 % non-linearity • Submersible • Withstands 250 psi, external pressure • Stainless steel construction • ±1,02 mm to 12,7 mm [±0.04 to ± 0.50 in range] • -4 °F to 257 °F operating range (standard) • Enhanced immunity to electrical noise • Captive guided spring return armature • Hermetically sealed, waterproof cable 1.83 m [6 ft] • Easy to operate • Infinite resolution • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S7C AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±1,02 mm to 12,7 mm [±0.04 in to 0.50 in] HK ±1,02 mm [±0.04 in] HM ±2,54 mm [±0.10 in] HN ±5,08 mm [±0.20 in] HF ±7,62 mm [±0.30 in] HG ±10,16 mm [±0.40 in] HP ±12,7 mm [±0.50 in] Non-linearity (max.) ±0.25 % full scale Non-repeatability <10 microinches Output sensitivity 2 mV/V/ 0.001 in Output load 100000 ohm Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -20 °C to 125 °C [-4 °F to 257 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Temperature effect, span (max.) 0.006 % full scale/°F OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±1,02 mm to 12,7 mm [±0.04 in to ±0.5 in] Electrical termination Hermetically sealed waterproof cable (1,83 m [6 ft]) ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Hermetically sealed waterproof cable 1.83 m [6 ft] MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread Not applicable 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Submersible* Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L D X ** Total weight*** Max. spring force HK ±1,02 mm [±0.04 in] 50,8 mm [2.00 in] 8,00 mm [0.315 in] 11,43 mm [0.45 in] 51,03 g [1.8 oz] 21,62 g [7.5 oz] HM ±2,54 mm [±0.1 in] 64,01 mm [2.52 in] 9,53 mm [0.375 in] 11.68 mm [0.46 in] 82,21 g [2.9 oz] 141,75 g [5.0 oz] HN ±5,08 mm [±0.2 in] 69,85 mm [2.75 in] 9,53 mm [0.375 in] 12,19 mm [0.48 in] 82,21 g [2.9 oz] 141,75 g [5.0 oz] HF ±7,62 mm [±0.3 in] 95,25 mm [3.75 in] 9,53 mm [0.375 in] 18,23 mm [0.72 in] 110,56 [3.9 oz] 141,75 g [5.0 oz] HG ±10,16 mm [±0.4 in] 106,43 mm [4.19 in] 9,53 mm [0.375 in] 22,1 mm [0.87 in] 124,74 g [4.4 oz] 141,75 g [5.0 oz] HP ±12,7 mm [±0.5 in] 129,03 mm [5.08 in] 9,53 mm [0.375 in] 24,64 mm [0.97 in] 153,09 g [5.4 oz] 141,75 g [5.0 oz] WIRING CODES TYPICAL SYSTEM DIAGRAM Supply Red Supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) 5 For reference only Wire color Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S7C AC-AC NOTES * Not recommended for salt water use ** Dimensions at “X” at nominal electrical zero *** Excluding cable Submersible* Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008741-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model SSA AC-AC Sub-Sea Displacement Transducer DESCRIPTION Model SSA ac-ac displacement transducer is offered in ranges sor is made from 316 SS with all-welded construction. Honeywell from ±0.5 in up to ±4.0 in stroke length. The oceanographic type offers in-line amplifiers and digital indicators for both LVDT mod- of electrical plug allows the connection to be made underwater. els that provide ±5 Vdc, 10 Vdc or 4 mA to 20 mA and RS232 This Sub-Sea displacement sensor are pressure rated to operate outputs with zero and span adjustments. down to a depth of 7500 feet in sea water. The body of the sen- FEATURES • ±1.0 % non-linearity • Submersible • All welded 316 stainless steel construction • Easy to operate • Enhanced immunity to electrical noise • Up to 2286 m [7500 ft] depth • ±12,7 mm to 101,6 mm range [±0.5 in to ±4.0 in range] • Infinite resolution • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model SSA AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 101,6 mm [±0.5 in to 4.0 in] HP ±12,7 mm [±0.5 in] HQ ±25,4 mm [±1.0 in] HR ±50,8 mm [±2.0 in] HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] Non-linearity (max.) ±1.0 % full scale Output sensitivity Consult factory; 0.3 V RMS to 3.0 V RMS range dependent Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 50 °C [-40 °F to 122 °F] Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.005 % full scale/°F Operating pressure 3500 psi OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 101,6 mm [±0.5 in to 4 in] Electrical termination Submersible, neoprene and nickel-aluminum bronze connector molded to 1.83 m [6.0 ft] of neoprene jacketed cable ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (acceptable) 0.5 V RMS to 7 V RMS @ 5 kHz Ripple Not applicable Electrical termination Includes submersible, neoprene, and nickel-aluminum bronze connector molded to 1.83 m [6 ft] of neoprene jacketed 10,16 mm [0.40 in] diameter cable. The electrical connector may be mated under water up to 500 psi or 335,28 m [1100 ft]. Longer cable lengths are available up to 990,6 m [3250 ft]. Consult factory for information. MECHANICAL SPECIFICATIONS Characteristic Measure Case material 316 Stainless steel with all welded construction Probe material 316 Stainless steel with all welded construction Probe thread M10 x 1.5 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Sub-Sea Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X D1 D2 A B HP ±12,7 mm [±0.5 in] 223,52 mm [8.8 in] 53,34 mm [2.1 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HQ ±25,4 mm [±1.0 in] 251,46 mm [9.9 in] 66,04 mm [2.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HR ±50,8 mm [±2.0 in] 345,44 mm [13.6 in] 91,44 mm [3.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HS ±76,2 mm [±3.0 in] 434,34 mm [17.1 in] 116,84 mm [4.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HT ±101,6 mm [±4.0 in] 535,94 mm [21.1 in] 142,24 mm [5.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] WIRING CODES Wire color Dual power supply Black Excitation high White Excitation low Red Signal high Green Signal low For reference only TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model SSA AC-AC Sub-Sea Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008746-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model SSD DC-DC Sub-Sea Displacement Transducer DESCRIPTION Model SSD dc-dc displacement transducer is offered in ranges sor is made from 316 SS with all-welded construction. Honeywell from ±0.5 in up to ±4.0 in stroke length. The oceanographic type offers in-line amplifiers and digital indicators that provide ±5 of electrical plug allows the connection to be made underwater. Vdc, 10 Vdc or 4 mA to 20 mA and RS-232 outputs with zero and This Sub-Sea displacement sensor is pressure rated to operate span adjustments. down to a depth of 7500 feet in sea water. The body of the sen- FEATURES • ±1.0 % non-linearity • Submersible • All welded 316 stainless steel construction • Easy to operate • Up to 2286 m [7500 ft] depth • ±12,7 mm to 101,6 mm range [±0.5 in to ±4.0 in range] • Infinite resolution • Single or dual supply wiring (field selectable) • Reverse polarity protected • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model SSD DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±12,7 mm to 101,6 mm [±0.5 in to 4 in] HP ±12,7 mm [±0.5 in] Non-linearity (max.) ±1.0 % full scale HQ ±25,4 mm [±1.0 in] Output sensitivity ±5 Vdc HR ±50,8 mm [±2.0 in] Resolution Infinite HS ±76,2 mm [±3.0 in] HT ±101,6 mm [±4.0 in] ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -40 °C to 50 °C [-40 °F to 122 °F] (Note: -9 °C to 60 °C [15 °F to 140 °F] on 4 mA to 20 mA) Temperature effect, zero (max.) 0.005 % full scale/°F Temperature effect, span (max.) 0.015 % full scale/°F Operating pressure 3500 psi OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±12,7 mm to 101,6 mm [±0.5 in to 4 in] Electrical termination Submersible, neoprene and nickel-aluminum bronze connector molded to 1.83 m [6 ft] of neoprene jacketed cable ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Input supply (acceptable) 20 Vdc to 40 Vdc @ 25 mA Single floating supply Input supply (acceptable) ±10 Vdc to 20 Vdc @ 25 mA Dual supply Ripple 30 mV peak to peak Electrical termination Includes submersible, neoprene, and nickel-aluminum bronze connector molded to 1.83 m [6 ft] of neoprene jacketed 10,2 mm [0.40 in] diameter cable. The electrical connector may be mated under water up to 500 psi or 335,28 m [1100 ft]. Longer cable lengths are available up to 990,6 m [3250 ft]. Consult factory for information. MECHANICAL SPECIFICATIONS Characteristic Measure Case material 316 stainless steel with all welded construction Probe material 316 stainless steel with all welded construction Probe thread M10 x 1.5 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Sub-Sea Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range L X D1 D2 A B HP ±12,7 mm [±0.5 in] 223,52 mm [8.8 in] 53,34 mm [2.1 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HQ ±25,4 mm [±1.0 in] 251,46 mm [9.9 in] 66,04 mm [2.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HR ±50,8 mm [±2.0 in] 345,44 mm [13.6 in] 91,44 mm [3.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HS ±76,2 mm [±3.0 in] 434,34 mm [17.1 in] 116,84 mm [4.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] HT ±101,6 mm [±4.0 in] 535,94 mm [21.1 in] 142,24 mm [5.6 in] 38,1 mm [1.5 in] 9,91 mm [0.39 in] 91,44 mm [3.6 in] 30,48 mm [1.2 in] WIRING CODES For reference only Wire color or pin Single supply* designation Dual supply designation Red or A 20 V to 40 V 10 V to 20 V Green or B Supply common -10 V to -20 V Black or C Output common** 0 V common White or D Output Output * Supply must be fully floating ** Output common floats at V supply/2 Min 2000 ohms with dual supply, 20000 ohms with single supply TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model SSD DC-DC NOTES Sub-Sea Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008747-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MS3 DC-DC Miniature Displacement Transducer DESCRIPTION Model MS3 (free unguided armature) dc-dc miniature displace- to larger, more expensive units. This model is compatible with ment transducer is ideally suited for multi-point applications dc data logging equipment used for taking readings from strain with space constraints and provide a cost-effective alternative gages or other dc operated transducers. FEATURES • Miniature design • Cost efficient • 0.25 % non-linearity • Stainless steel construction • ±0.1 in to ±0.4 in range • Infinite resolution • Single or dual supply wiring (field selectable) • Free unguided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MS3 DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±2,54 mm to 10,16 mm [±0.1 in to 0.4 in] HM ±2,54 mm [±0.1 in] HN ±5,08 mm [±0.2 in] HF ±7,62 mm [±0.3 in] HG ±10,16 mm [±0.4 in] Non-linearity (max.) ±0.25 % full scale Output impedance 2 ohm Output load (min.) 2000 ohm Output sensitivity ±5 Vdc or 0 Vdc to 10 Vdc (field selectable) Resolution Infinite OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Stroke ranges ±25,4 mm to 101,6 mm [±0.1 in to 4 in] Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) 6a. Bendix PTIH-10-6P right angle Bendix 0.017 % full scale/°F Electrical cable orientation Ra. Right angle Temperature effect, span (max.) Mounting threads 13a. 1/2-20 UNF 13f. 3/8-32 UNF Improved linearity L10. 0.1 % on some models ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Power supply, single 24 Vdc to 40 Vdc @ 30 mA Power supply, dual ±12 Vdc to ±20 Vdc @ 30 mA Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M3 x 0.5 Weight 73,5 g [2.6 oz] 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Miniature Displacement Transducer MOUNTING DIMENSIONS WIRING CODES Wire color Dual supply Single supply (floating)* Outputs Red 12 V to 20 V input 24 V to 40 V input Blue -12 V to -20 V input Supply negative For reference only Black OV, I/P, O/P common TYPICAL SYSTEM DIAGRAM Yellow 0 V to 10 V Green ±5 Vdc * Output common floats at voltage source/2 Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MS3 DC-DC NOTES Miniature Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008758-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S3C DC-DC Miniature Displacement Transducer DESCRIPTION Model S3C (captive guided spring return armature) dc-dc min- alternative to larger, more expensive units. This model is com- iature displacement transducer is ideally suited for multi-point patible with dc data logging equipment used for taking readings applications with space constraints and provide a cost-effective from strain gages or other dc operated transducers. FEATURES • Miniature design • Cost efficient • 0.25 % non-linearity • Stainless steel construction • ±0.1 in to ±0.4 in range • Infinite resolution • Single or dual supply wiring (field selectable) • Captive guided spring return armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S3C DC-DC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±2,54 mm to 10,16 mm [±0.1 in to 0.4 in] HM ±2,54 mm [±0.1 in] Non-linearity (max.) ±0.25 % full scale HN ±5,08 mm [±0.2 in] Output impedance 2 ohm HF ±7,62 mm [±0.3 in] Output load (min.) 2000 ohm HG ±10,16 mm [±0.4 in] Output sensitivity ±5 Vdc or 0 Vdc to 10 Vdc (field selectable) Resolution Infinite OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Stroke ranges ±5,08 mm [±0.2 in], ±2,54 mm [±0.1 in], ±7,62 mm [±0.3 in], ±10,16 mm [±0.4 in] ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -50 °C to 70 °C [-58 °F to 158 °F] Temperature effect, zero (max.) 0.006 % full scale/°F Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) 6a. Bendix PTIH-10-6P right angle Bendix Temperature effect, span (max.) 0.017 % full scale/°F Electrical cable orientation Ra. Right angle Mounting threads 13a. 1/2-20 UNF 13f. 3/8-32 UNF Improved linearity L10. 0.1 % on some models ELECTRICAL SPECIFICATIONS Characteristic Measure Element type dc-dc displacement transducer Power supply, single 24 Vdc to 40 Vdc @ 30 mA Power supply, dual ±12 Vdc to ±20 Vdc @ 30 mA Electrical termination Multiconductor shielded cable (1.83 m [6 ft]) MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Captive guided spring return Probe thread Not applicable Weight 82,5 g [2.91 oz] 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Miniature Displacement Transducer MOUNTING DIMENSIONS WIRING CODES Wire color Dual supply Single supply (floating)* Outputs Red 12 V to 20 V input 24 V to 40 V input – Blue -12 V to -20 V input Supply negative – Black OV, I/P, O/P common – – For reference only TYPICAL SYSTEM DIAGRAM Yellow – – 0 V to 10 V Green – – ±5 Vdc * Output common floats at voltage source/2 Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model S3C DC-DC NOTES Miniature Displacement Transducer 1. GM-A should not be used with an amplified displacement transducer unless using an external power supply to power the displacement transducer. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Find out more WARNING Honeywell serves its customers MISUSE OF DOCUMENTATION through a worldwide network of •The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s Failure to comply with these instructions could result in death or serious injury. test and measurement products, call +1-614-850-5000, visit www.honeywell.com/sensotec, or e-mail inquiries to info.tm@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008757-2-EN IL50 GLO September 2009 Copyright © 2009 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model M-5C AC-AC Miniature Displacement Transducer DESCRIPTION Model M-5C ac-ac miniature displacement transducers are practical. High electrical output, exceptional linearity and rugged, stable, and compact transducers, which provide high infinite resolution enable these units to be effective in a variety of accuracy static and dynamic displacement measurement. applications. M-5C has a free unguided armature, which may be These units are easily mounted in any position, at remote or mounted to be virtually friction-free. The displacement transduc- hazardous locations where direct measurement would not be er’s body and armature are separable. FEATURES • Miniature design • Rugged, enhanced accuracy • Enhanced immunity to electrical noise • ±0.025 in to ±0.5 in range • -58 °F to 257 °F operating range (standard) • Extended life cycle • Infinite resolution • Free unguided armature • Not RoHS compliant Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model M-5C AC-AC PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Stroke range ±2,54 mm to 12,7 mm [±0.10 in to 0.50 in] HM ±2,54 mm [±0.10 in] Non-linearity (max.) ±0.25 % full scale HN ±5,08 mm [±0.20 in] Non-repeatability Not measureable HF ±7,62 mm [±0.30 in] Output sensitivity See table HG ±10,16 mm [±0.40 in] Output load (min.) 100 ohm HP ±12,7 mm [±0.50 in] Resolution Infinite Phase shift <10° @ 5 kHz OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Stroke ranges ±2,54 mm to 12,7 mm [±0.1 in to ±0.5 in] Temperature, operating -20 °C to 125 °C [-4 °F to 257 °F] Multiconductor shielded cable (1,83 m [6 ft]) Temperature effect, zero (max.) 0.006 % full scale/°F Electrical termination Temperature effect, span (max.) 0.006 % full scale/°F Electrical cable orientation Ra. Right angle cable exit Mounting threads 13g. 1/8 in BSP Improved linearity L10. ±0.1 % max. linearity (less than or equal to 101,6 mm [±4.0 in] ELECTRICAL SPECIFICATIONS Characteristic Measure Element type ac-ac displacement transducer Input supply (calibrated) 5 V RMS @ 5 kHz Input supply (acceptable) 1 V to 7 V RMS @ 2 kHz to 10 kHz Electrical termination Multiconductor shielded cable 1.83 m [6 ft] MECHANICAL SPECIFICATIONS Characteristic Measure Case material Stainless steel Probe material Stainless steel Armature type Free unguided Probe thread M3 x 0.5 Weight See table 2 Honeywell • Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Miniature Displacement Transducer MOUNTING DIMENSIONS Range code Available stroke range HJ HM L mm [in] X mm [in] D mm [in] D1 mm [in] T mm [in] Total weight g [oz] Armature weight g [oz] Output sensitivity mV/V/ 0.001 in ±0,635 [±0.025] 35,05 [1.38] 27,94 [1.1] 9,53 [0.375] 1,91 [0.075] 19,05 [0.75] 14,17 [0.5] 1,28 [0.045] 2 ±2,54 [±0.1] 42,93 [1.69] 19,05 [0.75] 9,53 [0.375] 2,29 [0.09] 14,99 [0.59] 15,88 [0.56] 1,41 [0.05] 4 HN ±5,08 [±0.2] 55,88 [2.2*] 25,4 [1.0] 9,53 [0.375] 2,03 [0.08] 18,03 [0.71] 17,86 [0.63] 1,98 [0.07] 4* HF ±7,62 [±0.3] 57,91 [2.28] 29,97 [1.18] 9,53 [0.375] 2,03 [0.08] 18,03 [0.71] 22,11 [0.78] 2,21 [0.078] 2 HG ±10,16 [±0.4] 63 [2.48] 32,51 [1.28] 9,53 [0.375] 2,03 [0.08] 18,03 [0.71] 28,07 [0.99] 1,9 [0.067] 2 HP ±12,7 [±0.5] 79 [3.11] 34,8 [1.37] 9,53 [0.375] 2,03 [0.08] 18,03 [0.71] 36,0 [1.27] 2,3 [0.081] 2 WIRING CODES For reference only Wire color Supply Red (+) supply (calibrated @ 5 V RMS, 5 kHz) Yellow Supply return Blue Output Green Output return Black Secondary center tap (normally not connected) Cable shield is not connected to transducer 5 TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model M-5C AC-AC Miniature Displacement Transducer Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008750-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com