未命名 -1 - BRK Technologies sro

advertisement
3
Installation Equipments
3/0
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Contents
Installation Switches
BZM Series Explosion-proof Illumination Switches (Ex d IIC)
3/2
Junction Boxes
BHD51 Series Explosion-proof Junction Boxes (Ex d IIC)
3/4
BHD91 Series Explosion-proof Junction Boxes (Ex d IIC)
3/6
Terminal Boxes
BXJ-IIB Series Explosion-proof Terminal Boxes (Ex d IIB)
BXJ-IIC Series Explosion-proof Terminal Boxes (Ex d IIC)
BXJ-e Series Terminal Boxes (Ex e Ex i)
BXJ8050 Series Terminal Boxes (Ex e Ex i)
BXJ8050-20/6 Series Junction Boxes (Ex e)
BXJ-S Series Terminal Boxes (Ex e Ex i)
3/8
3/12
3/14
3/18
3/22
3/24
Plug and Sockets
Introduction of the voltage, pole number, clock position and colour of explosion-proof plug and sockets
BCZ8060 Series Explosion-proof Plug and Sockets (Ex d e IIC)
BCZ85 Series Explosion-proof Plug and Sockets (Ex d IIC)
BCZ54 Series Explosion-proof Plug and Sockets (Ex d e IIB Ex d IIB)
BLJ85 Series Explosion-proof Plug Connectors (Ex d e IIC)
BCZY Series Explosion-proof Movable Switchboards (Ex d e IIC)
3/28
3/30
3/38
3/44
3/48
3/52
More products are under development. Please contact us or visit our website for the latest product development. We
reserve the right to make alteration to the technical data, weight, dimensions, designs and products available without
notice.
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/1
3
Installation Switches
BZM Series Explosion-proof Illumination Switches
◆ Explosion protection to
-CENELEC
-IEC
-NEC
◆ Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 1, Groups A, B, C, D
◆ Copper-free aluminium enclosure, powder coated surface.
◆ Two options:
-On-off switch
-Changeover switch
■ Catalogue number logic
BZM -
Switch type (B: on-off switch D: changeover switch)
Rated current (A)
Explosion-proof illumination switches
Selection table
Type/Ordering code
Chart of contact
Corresponding switch
Weight (kg)
BZM-16B
0.85
BZM-25B
0.95
BZM-16D
0.85
BZM-25D
0.95
Zones 1&2; 21&22
3/2
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Installation Switches
BZM Series Explosion-proof Illumination Switches
Technical data
Explosion-proof illumination switches
BZM-□□
Explosion protection
Gas explosion protection
Dust explosion protection
II 2 G Ex d IIC T6 Gb
II 2 D Ex tb IIIC T80℃ Db IP66
Certificates
LCIE 06 ATEX 6068; IECEx LCI 08. 0008
Conformity to standards
EN 60079-0:2012, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2011, IEC 60079-1:2007, IEC 60079-31:2008
Enclosure material
Copper-free aluminium, powder coated surface
Enclosure colour
Window grey (RAL7040)
Switch function
On-off switch or changeover switch
Exposed fastener
Stainless steel
Rated voltage
Max. 250V AC
Rated current
16A, 25A
Degree of protection
IP66, IP67 (optional)
Ambient temperature
-60℃~+60℃
Cable connection
3 x (2.5~4)mm2
Cable entries
Standard 2 x M25 x 1.5 plugs
2 x G3/4" plugs or 2 x NPT3/4" plugs on request
Cable gland(optional)
DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~27.
Spare parts
Built-in switch
Rated voltage/current
Ordering code
Weight (kg)
250V/16A
30001
0.10
250V/25A
30002
0.20
250V/16A
30003
0.10
250V/25A
30004
0.20
Dimension drawings (all dimensions in mm) - subject to alteration
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/3
3
Junction Boxes
BHD51 Series Explosion-proof Junction Boxes
◆ Explosion protection to
-CENELEC
-IEC
-NEC
◆ Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 1, Groups A , B, C, D
◆ Six types: A, B, C, D, E, F.
◆ Type A, B, C, D, E in copper-free aluminium only; Type F in
copper-free aluminium or cast iron.
■ Catalogue number logic
BHD51 - □ / □/ □
T: cast iron (only for Type F)
Thread (M, G, NPT)
Outline code (A, B, C, D, E, F)
Explosion-proof junction boxes
Selection table
Type/Ordering code
Schematic diagram
Weight (kg)
BHD51-A/M20 x 1.5
Type A
0.70
BHD51-A/M25 x 1.5
BHD51-B/M20 x 1.5
Type B
0.70
BHD51-B/M25 x 1.5
BHD51-C/M20 x 1.5
Type C
0.70
BHD51-C/M25 x 1.5
BHD51-D/M20 x 1.5
Type D
0.70
BHD51-D/M25 x 1.5
BHD51-E/M20 x 1.5
Type E
0.70
BHD51-E/M25 x 1.5
BHD51-F/M25 x 1.5
Copper-free aluminium
0.80
Cast iron
2.10
Type F
Zones 1&2; 21&22
3/4
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Junction Boxes
BHD51 Series Explosion-proof Junction Boxes
Technical data
Explosion-proof junction boxes
BHD51-□/□/□
Explosion protection
Gas explosion protection
II 2 G Ex d IIC T6 Gb
Dust explosion protection
II 2 D Ex t IIIC T80℃ Db IP66
Certificates
LCIE 11 ATEX 3005; IECEx CQM 11.0022X; RU C-CN.ГБ05.B.00345(CU-TR)
Conformity to standards
EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008
Enclosure material
Copper-free aluminium or cast iron, powder coated surface
Enclosure colour
Yellow (RAL1021)
Exposed fastener
Stainless steel
Rated current
20A
Rated voltage
Max. 500V AC
Terminal data
Number
6 terminals (Type A-E), 4 terminals (Type F)
Cross section of cable
0.2~2.5mm2
Degree of protection
IP66, IP67 (optional)
Ambient temperature
-60℃~+55℃
Cable entries
Standard M□ x 1.5 plug
G□ plug or NPT□ plug on request (see Selection table)
Cable gland(optional)
DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~27.
Main application
Type A-E are used for wiring or branching;
Type F is used as accessory for pendant pole type or ceiling type light fittings.
Terminals
Number
Ordering code
Weight (kg)
Note
Terminal
6
30008
0.10
A, B, C, D, E
Terminal block
4
30009
0.05
For Type F
Description
Illustration
For Type
Dimension drawings (all dimensions in mm) - subject to alteration
Copper-free aluminium
View A
Type A, B, C, D, E
Cast iron
View A
Φ9
Type F
Application instruction:
1. Type F (copper-free aluminium) is used as mounting accessory for light fittings BAD61-125, BAD81, BAD, BDD81, BAD85 etc.
2. Type F (cast iron) is used as mounting accessory for light fittings BAD61-250, BAD61-400, etc.
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/5
3
Junction Boxes
BHD91 Series Explosion-proof Junction Boxes
◆ Explosion protection to
-CENELEC
-IEC
-NEC
◆ Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 1, Groups A , B, C, D
◆ Six types: A, B, C, D, E, F.
◆ Copper-free aluminium enclosure, powder coated surface.
■ Catalogue number logic
BHD91 -
/
Thread (M, G, NPT)
Outline code (A, B, C, D, E, F)
Explosion-proof junction boxes
Selection table
Type /
Ordering code
Schematic diagram
Top
Bottom
Left
Right
Weight (kg)
BHD91-A
Type A
2-M25×1.5
2-M25×1.5
2-M25×1.5
2-M25×1.5
1.20
BHD91-B
Type B
1-M32×1.5
1-M32×1.5
1-M32×1.5
1-M32×1.5
1.20
BHD91-C
Type C
1-M32×1.5
1-M32×1.5
1-M32×1.5
2-M25×1.5
1.20
BHD91-D
Type D
1-M32×1.5
1-M32×1.5
2-M25×1.5
2-M25×1.5
1.20
BHD91-E
Type E
2-M25×1.5
1-M32×1.5
2-M25×1.5
1-M32×1.5
1.20
BHD91-F
Type F
2-M25×1.5
1-M32×1.5
2-M25×1.5
2-M25×1.5
1.20
Zones 1&2; 21&22
3/6
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Junction Boxes
BHD91 Series Explosion-proof Junction Boxes
Technical data
Explosion-proof junction boxes BHD91-□/□
Explosion protection
Gas explosion protection
II 2 G Ex d IIC T6 Gb
Dust explosion protection
II 2 D Ex tb IIIC T80℃ Db IP66
Certificates
LCIE 15 ATEX ____; IECEx
Conformity to standards
EN 60079-0:2012, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2011, IEC 60079-1:2007, IEC 60079-31:2008
Enclosure material
Copper-free aluminium, powder coated surface
Enclosure colour
Yellow (RAL1021)
Exposed fastener
Stainless steel
Rated voltage
Max. 500V AC
Rated current and Terminal data
Cross section
2.5mm2
4mm2
6mm2
Rated current
24A
32A
41A
12
10
8
Terminal number
Degree of protection
IP66, IP67 (optional)
Ambient temperature
-60℃~+55℃
Cable entries
Standard M□ x 1.5 plug
G□ plug or NPT□ plug on request (see Selection table)
DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~27.
Cable gland(optional)
Dimension drawings (all dimensions in mm) - subject to alteration
15
100
3
136
7
136
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/7
3
Terminal Boxes
BXJ Series Explosion-proof Terminal Boxes
◆ Explosion protection to
-CENELEC
-IEC
-NEC
◆ Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 1, Groups A, B, C, D
Class I, Division 2, Groups A , B, C, D
◆ Three explosion-proof types (Ex e, Ex d IIB and Ex d IIC).
◆ Enclosure: Copper-free aluminium (carbon steel or stainless
steel is optional), powder coated surface.
◆ Size and direction of cable entries can be customized on
request.
Ex d IIB
■ Catalogue number logic
BXJ - □- □ □
Internal terminal type (a......f)
Enclosure type (I, II, III......)
Explosion-proof type (e, IIB, IIC)
Explosion-proof terminal boxes
Ex d IIC
Ex e IIC
Zones 1&2; 21&22
3/8
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ-IIB Series Explosion-proof Terminal Boxes
Technical data
Explosion-proof terminal boxes(Ex d IIB)
Explosion protection
Gas explosion protection
BXJ-IIB-□□
Ex d IIB T6 or T5 Gb
II 2 G Ex d IIB T6 Gb
Dust explosion protection
II 1 D Ex t IIIB T80
Da IP66
Ex tb IIIC T80
LCIE 11 ATEX 3013;
Certificates
or T95
Db IP66
IECEx CQM 14. 0061X;
RU C-CN.ГБ05.B.00345(CU-TR);
Conformity to standards
EN 60079-0: 2009, EN 60079-1: 2007, EN 60079-31: 2009
IEC 60079-0: 2011, IEC 60079-1: 2007, IEC 60079-31: 2008
Copper-free aluminium (carbon steel or stainless steel is optional), powder coated surface
Window grey (RAL7040)
International brand of terminal
Stainless steel
Enclosure material
Enclosure colour
Terminal
Exposed fastener
Ambient temperature
T6/T80℃ for Tamb: -60℃~+40℃, T5/T95℃ for Tamb: -60℃~+55℃
Max. 800V AC (IECEx certificate)
-60℃~+55℃
Max. 500V AC (ATEX certificate)
Rated voltage
Rated current
Cross section
2.5mm2
4mm2
6mm2
10mm2
16mm2
35mm2
70mm2
240mm2
Rated current
24A
32A
41A
57A
76A
125A
192A
400A
IP66, IP67 (optional)
Rated current > 400A on request
Degree of protection
Note
Cable entry table
Table of max. number of possible enclosure entries with cable glands DQM-II
I
Size
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
A/B
5
5
2
2
1
1
C/D
8
7
3
2
2
2
A/B
5
5
2
2
1
1
V
Size
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
A/B
14
12
10
4
4
3
II b
II
C/D
10
9
4
3
3
2
C/D
12
10
6
4
3
3
A/B
5
5
2
2
1
1
A/B
24
18
14
8
5
4
A/B
10
9
7
3
3
2
C/D
12
11
9
4
3
3
VI
Vb
C/D
21
19
15
7
5
5
III b
III
C/D
40
27
21
12
9
7
A/B
19
16
13
7
6
3
A/B
16
12
9
5
4
2
C/D
20
15
12
6
5
3
A/B
12
11
9
4
3
3
VI b
C/D
33
28
22
13
11
5
A/B
30
20
18
11
6
5
IV b
IV
C/D
16
14
12
5
4
3
A/B
22
15
12
6
5
3
VII b
VII
C/D
50
36
30
18
10
9
A/B
28
25
21
11
10
4
C/D
30
20
16
9
7
5
C/D
41
35
29
16
13
6
A/B
45
30
25
15
12
7
C/D
65
44
36
21
12
10
Note: 1. No cable entries for standard design. Cable entries shall be drilled by user.
2. For cable entries:
1) Please specify the direction and size of each cable entry.
2) Cable gland is optional, DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~27.
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/9
3
Terminal Boxes
BXJ-IIB Series Explosion-proof Terminal Boxes
Selection table of BXJ-IIB series explosion-proof terminal boxes
Max. cross section of cable connected to terminals is 35mm2
See table for max. number of fitted terminals
Cross section of cable (mm2)
2.5 (a)
4 (b)
6 (c)
10 (d)
16 (e)
35 (f)
I
16
15
12
10
8
II
22
18
14
12
II b
28
25
20
15
Enclosure code/Ordering code
Outline
Max. dissipated Weight
power (W)
(kg)
——
9.8
7.50
10
——
14.4
9.00
12
——
14.4
10.00
16.00
(III)
32
30
24
20
16
8
22.2
19.80
(III b)
III, III b
16.50
(III)
50
46
40
——
——
——
22.2
20.50
(III b)
25.50
(IV)
45
40
34
28
24
16
25.2
30.00
(IV b)
IV,IV b
26.30
(IV)
80
70
60
40
——
——
25.2
31.00
(IV b)
3/10
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ-IIB Series Explosion-proof Terminal Boxes
Selection table of BXJ-IIB series explosion-proof terminal boxes
Max. cross section of cable connected to terminals is 240mm2
See table for max. number of fitted terminals
Cross section of cable (mm2)
Enclosure code/
Ordering code
2.5 (a)
4 (b)
6 (c)
10 (d)
16 (e)
35 (f)
70 (g)
240 (h)
Outline
Max. dissipated Weight
power (W)
(kg)
38.00
(V)
60
56
48
36
30
20
——
——
55.3
43.00
(Vb)
V ,Vb
39.00
(V)
110
100
90
70
66
——
——
——
55.3
44.00
(Vb)
50.00
(VI)
80
70
60
50
35
20
10
6
64.5
56.50
(VIb)
VI,VIb
51.50
(VI)
160
140
120
100
70
——
——
——
64.5
58.00
(VIb)
80.00
(VII)
90
80
70
60
40
25
15
9
93.1
88.50
(VIIb)
VII,VIIb
82.00
(VII)
180
160
140
120
80
——
——
——
93.1
91.50
(VIIb)
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/11
3
Terminal Boxes
BXJ-IIC Series Explosion-proof Terminal Boxes
Technical data
Explosion-proof terminal boxes (Ex d IIC)
BXJ- IIC-□□
Explosion protection
Gas explosion protection
II 2 G Ex d IIC T6 Gb
Dust explosion protection
II 2 D Ex tb IIIC T80℃ Db IP65
Certificates
Nemko 09 ATEX 1012; IECEx CQM 11.0027; CU-TR
Conformity to standards
EN 60079-0:2012, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2011, IEC 60079-1:2007, IEC 60079-31:2008
Enclosure material
Copper-free aluminium (carbon steel or stainless steel is optional), powder coated surface
Enclosure colour
Window grey (RAL7040)
Terminal
International brand of terminal
Exposed fastener
Stainless steel
Rated voltage
Max. 690V AC
Rated current
2
Cross section 2.5mm
Rated current
Degree of protection
24A
4mm2
6mm2
10mm2
16mm2
35mm2
70mm2
95mm2
32A
41A
57A
76A
125A
192A
250A
IP65
Ambient temperature
-20℃~+55℃
Note
Rated current > 250A on request
Cable entry table
Table of max. number of possible enclosure entries with cable glands DQM-II
I
II
III
IV
V
VI
Size
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
M20×1.5
3
3
4
4
10
10
11
11
15
15
17
17
M25×1.5
3
3
4
4
9
9
10
10
13
13
15
15
M32×1.5
2
2
3
3
7
7
8
8
11
11
12
12
M40×1.5
2
2
3
3
3
3
4
4
5
5
5
5
M50×1.5
/
/
/
/
3
3
3
3
4
4
5
5
M63×1.5
/
/
/
/
2
2
2
2
3
3
4
4
Note: 1. No cable entries for standard design. Cable entries shall be drilled by user.
2. For cable entries:
1) Please specify the direction and size of each cable entry.
2) Cable gland is optional, DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~27.
3/12
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ-IIC Series Explosion-proof Terminal Boxes
Selection table of BXJ-IIC series explosion-proof terminal boxes
Max. cross section of cable connected to terminals is 95mm2
See table for max. number of fitted terminals
Cross section of cable (mm2)
Weight
2.5 (a)
4 (b)
6 (c)
10 (d)
16 (e)
35 (f)
70 (g)
95 (h)
I
10
8
6
—
—
—
—
—
3.50
II
20
18
15
12
10
—
—
—
6.50
III
25
24
20
15
12
6
—
—
12.00
32
30
25
18
14
10
—
—
15.00
44
40
32
22
—
—
—
—
15.50
48
44
38
30
20
12
6
6
21.00
72
60
50
40
—
—
—
—
21.50
60
54
44
34
26
15
8
8
24.00
90
80
60
50
40
—
—
—
24.50
Enclosure code/Ordering code
Outline
(kg)
IV
V
VI
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/13
3
Terminal Boxes
BXJ-e Series Terminal Boxes
Technical data
Terminal boxes (Ex e IIC Ex ib IIC)
BXJ-e-□□
Explosion protection
Gas explosion protection
II 2 G Ex e IIC T6 or T5 Gb
Dust explosion protection
II 2 D Ex tb IIIC T80℃ Db IP66
II 2 G Ex ib IIC T6 Gb
Certificates
LCIE 13 ATEX 3027X; IECEx CQM 13.0032X; RU C-CN.ГБ05.B.00345(CU-TR)
Conformity to standards
EN 60079-0:2009, EN 60079-7:2007, EN 60079-11:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-7:2006, IEC 60079-11:2006, IEC 60079-31:2008
Enclosure material
Copper-free aluminium, powder coated surface
Enclosure colour
Window grey (RAL7040)
Terminal
International brand of explosion-proof terminal
Ex-mark:
II 2 GD Ex e II
Exposed fastener
Stainless steel
Rated voltage
Max. 690V AC
Rated current
Cross section
Ex e Rated current
Ex ib Rated current
Degree of protection
IP66, IP67 (optional)
4mm2
32A
5A
2.5mm2
24A
-
6mm2
41A
5A
10mm2
57A
-
16mm2
76A
-
35mm2
125A
-
Ex e: T6 for Tamb: -50℃ ~ +40℃; T5 for Tamb: -50℃ ~ +55℃
Ambient temperature
Ex ib: T6 for Tamb: -50℃ ~ +55℃
Ex e
Note
Rated current > 125A on request.
Cable entry table
Table of max. number of possible enclosure entries with cable glands DQM-I
I
II
III
IV
V
VI
VII
VIII
Size
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
M20 x 1.5
2
3
4
4
4
6
6
6
6
10
10
10
8
12
12
18
M25 x 1.5
2
3
3
3
3
4
4
4
5
9
9
9
7
10
10
16
M32 x 1.5
1
2
2
2
2
3
3
3
3
4
4
4
4
6
6
10
M40 x 1.5
1
2
2
2
2
3
3
3
2
3
3
3
2
3
3
5
M50 x 1.5
/
/
/
/
/
/
/
/
/
3
3
3
2
3
3
5
M63 x 1.5
/
/
/
/
/
/
/
/
/
2
2
2
2
3
3
4
Note: 1. No cable entries for standard design. Cable entries shall be drilled by user.
2. For cable entries:
1) Please specify the direction and size of each cable entry.
2) Cable gland is optional, DQM-I (Ex e) is recommended. Please see P7/17~19.
3/14
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ-e Series Terminal Boxes
Selection table of BXJ-e series terminal boxes
Max. cross section of cable connected to terminals is 35mm2
See table for max. number of fitted terminals
Cross section of cable (mm2)
Max. dissipated
Weight
power (W)
(kg)
—
7.83
2.40
8
—
11.81
2.80
15
12
—
8.60
3.80
20
15
12
8
10.63
5.10
30
25
20
15
—
11.34
5.80
30
25
20
15
10
2.5 (a)
4 (b)
6 (c)
10 (d)
16 (e)
35 (f)
I
16
15
12
10
—
II
16
15
12
10
III
25
22
20
IV
25
22
V
35
35
Enclosure code/Ordering code
Outline
24.68
VI
60
50
40
—
—
—
7.50
40
35
30
24
18
12
7.00
20.44
VII
40
40
30
—
—
—
7.00
60
55
40
30
20
15
9.50
23.75
VIII
100
General Catalogue 01.01.2015
7.10
http:// www.waromgroup.com
90
66
60
40
—
9.70
3/15
3
Terminal Boxes
BXJ Series Explosion-proof Terminal Boxes
Dimension drawings (all dimensions in mm) - subject to alteration
BXJ- IIB-
Type II
Type I
Type IIb
Type III,IIIb
Type IV,IVb
Type V,Vb
Type VI,VIb
Type VII,VIIb
3/16
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ Series Explosion-proof Terminal Boxes
Dimension drawings (all dimensions in mm) - subject to alteration
BXJ- IIC-
Type I
Type II
Type IV
Type III
Type V
Type VI
Dimension drawings (all dimensions in mm) - subject to alteration
Type I
Type II
Type VI
General Catalogue 01.01.2015
143
143
143
143
BXJ- e-
Type III
Type VII
http:// www.waromgroup.com
Type IV
Type V
Type VIII
3/17
3
Terminal Boxes
BXJ8050 Series Terminal Boxes
◆ Explosion protection to
-CENELEC
-IEC
-NEC
◆ Can be used in
Zone 0, Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 2, Groups A , B, C, D
◆ GRP (glass fibre-reinforced polyester resin) enclosure.
◆ International brand of explosion-proof terminal.
■ Catalogue number logic
BXJ8050 - □ □
Internal terminal type (a......f)
Enclosure type (I, II, III...)
Terminal boxes (GRP)
Zones 0&1&2; 21&22
3/18
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ8050 Series Terminal Boxes
Technical data
Terminal boxes (Ex e IIC Ex ia IIC)
BXJ8050-□□
Explosion protection
Gas explosion protection
II 2 G Ex e IIC T6 or T5 Gb
Dust explosion protection
II 1 G Ex ia IIC T6 Ga
II 2 D Ex tb IIIC T80℃ Db IP66
Certificates
LCIE 13 ATEX 3036X; IECEx CQM 13.0031X
Conformity to standards
EN 60079-0:2009, EN 60079-7:2007, EN 60079-11:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-7:2006, IEC 60079-11:2006, IEC 60079-31:2008
Enclosure material
GRP (glass fibre-reinforced polyester resin)
Terminal
International brand of explosion-proof terminal
Ex-mark:
II 2 GD Ex e II
Exposed fastener
Stainless steel
Rated voltage
Max. 690V AC
Rated current
Cross section
Ex e Rated current
Ex ia Rated current
4mm2
32A
5A
2.5mm2
24A
-
6mm2
41A
5A
10mm2
57A
-
Degree of protection
IP66, IP67 (optional)
Ambient temperature
Ex e: T6 for Tamb: -40℃ ~ +40℃; T5 for Tamb: -40℃ ~ +55℃
16mm2
76A
-
35mm2
125A
-
Ex ia: T6 for Tamb: -40℃ ~ +55℃
Ex e
Note
Rated current > 125A on request.
Cable entry table
Table of max. number of possible enclosure entries with cable glands DQM-I
I
II
III
IV / IVB
V / VB
VI
VII / VIIB
Size
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
A/B
C/D
M16×1.5
4
4
6
10
10
12
12
18
18
18
7
12
18
36
M20×1.5
2
2
5
8
8
8
10
12
12
12
4
8
12
24
M25×1.5
2
2
2
4
6
6
6
10
10
10
3
4
10
18
M32×1.5
/
/
2
3
2
2
3
5
5
5
2
2
5
8
M40×1.5
/
/
1
2
2
2
2
4
4
2
1
2
4
6
M50×1.5
/
/
/
/
/
/
/
/
/
/
/
/
3
6
Note: 1. No cable entries for standard design. Cable entries shall be drilled by user.
2. For cable entries:
1) Please specify the direction and size of each cable entry.
2) Cable gland is optional, DQM-I (Ex e) is recommended. Please see P7/16.
General Catalogue 01.01.2015
http:// www.waromgroup.com
3/19
3
Terminal Boxes
BXJ8050 Series Terminal Boxes
Selection table of BXJ8050 series terminal boxes
Max. cross section of cable connected to terminals is 35mm2
See table for max. number of fitted terminals
Cross section of cable (mm2)
2.5 (a)
4 (b)
6 (c)
10 (d)
16 (e)
35 (f)
12
10
8
—
—
II
25
22
18
—
III
30
28
22
18
Enclosure code/Ordering code
I
Max. dissipated Weight
power (W)
(kg)
—
2.30
0.80
—
—
6.81
1.30
15
—
6.50
2.10
Outline
130
3.25
IV
44
40
32
25
20
—
14.32
IVB
4.00
V
4.15
88
80
60
50
40
14
28.08
5.20
VB
VI
25
22
18
14
—
—
7.92
14.55
VII
180
160
130
100
80
30
25.00
16.75
VIIB
3/20
2.00
General Catalogue 01.01.2015
http:// www.waromgroup.com
3
Terminal Boxes
BXJ8050 Series Terminal Boxes
Dimension drawings (all dimensions in mm) - subject to alteration
Type I
Type II
121(171)
Type III
Type IV, IVB
121(171)
Type V, VB
Type VI
171(230)
Type VII, VIIB
General Catalogue 01.01.2013
http:// www.waromgroup.com
3/21
Download