PRICE BOOK - TECO-Westinghouse Motors (Canada) Inc.

advertisement
TECO-WESTINGHOUSE MOTORS (CANADA) INC.
MOTORS AND CONTROLS
PRICE BOOK
MOTOR PRODUCT INDEX
PRODUCT
SECTION
MOTORS
No.
MOTORS
THREE PHASE TEFC
Rolled Steel TEFC
1
Optim® TEFC
4
Advantage Plus IEEE Ready
11
Advantage Plus IEEE 841
18
Advantage Plus Mine Duty
25
Optim® TEXP
32
Optim® Oilwell
37
MAX-HT
39
THREE PHASE ODP
A
Rolled Steel ODP
42
Optim® ODP
45
MEDIUM VOLTAGE
Global XPE
50
Global ODP
53
SINGLE PHASE
Farm Duty
56
PUMP MOTORS
Optim® JP
58
Optim® JM
61
Optim® VH
64
Rolled Steel TEFC
Optim® TEFC
Advantage Plus
IEEE Ready
Advantage Plus
IEEE 841
Advantage Plus
Mine Duty
Optim® TEXP
A-1
A-4
A-11
A-18
A-25
A-32
Optim® Oilwell
MAX-HT
Rolled Steel ODP
Optim® ODP
Global XPE
Global ODP
A-37
A-39
A-42
A-45
A-50
A-53
Farm Duty
Optim® JP
Optim® JM
Optim® VH
A-56
A-58
A-61
A-64
Motor Product Index
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
1
PARTS & ACCESSORIES INDEX
PRODUCT
SECTION
PARTS & ACCESSORIES
No.
C-Flange Kits - TEFC - Cast-Iron
Optim® TEFC / Global XPE
1
Advantage Plus IEEE Ready
1
Advantage Plus IEEE 841
1
C-Flange Kits - ODP - Cast-Iron
Optim® ODP
2
PARTS & ACCESSORIES
C-Flange Kits - TEFC - Rolled Steel
Farm Duty
2
Rolled Steel TEFC
2
C-Flange Kits - ODP - Rolled Steel
Rolled Steel ODP
3
C-Flange Kits - TEXP
Optim® TEXP
3
Blower Kits
Frames 140T thru 400T
B
4
Slide Bases
Frames 56 thru 324T
5
Labyrinth Seals - Advantage Plus IEEE 841 / Optim® HE Plus / Global
Inpro/Seal (VBXX)
6
Pro-Tech Seal
6
Shaft Grounding Rings
AEGIS (SGR)
7
Labyrinth Seals C/W Shaft Grounding Rings
Inpro/Seal (MGS)
8
Couplings (For Optim® VH Vertical Hollowshaft Motors)
Frames 210TP thru 445TP20 / 447/9TP
9
Steady Bushing (For Optim® VH Vertical Hollowshaft Motors)
Frames 210TP thru 445TP20 / 447/9TP
10
Alternate P-Flange Kits (For Optim® VH Vertical Hollowshaft Motors)
Frames 250TP thru 447/9TP
11
NRP Ball Ratchets (For Optim® VH Vertical Hollowshaft Motors)
Frames 210TP thru 445TP20 / 447/9TP
2
Parts & Accessories Index
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
11
MODIFICATION & DESCRIPTION INDEX
MOTOR MODIFICATIONS
PRODUCT SECTION
B
BEARING
MODIFICATION
PRODUCT
No.
DESCRIPTION
C-Flange - ODP
MODIFICATIONS
12
16
Special Grease
MODIFICATIONS
No.
13
17
C-Flange - TEFC
12
16
Nameplate Change
13
17
C-Flange with Inpro/Seal (ADV+)
12
16
Additional Nameplate - Information Plate
13
17
D-Flange - ODP
12
16
Ground Provision
13
17
D-Flange - TEFC
12
16
Breather Drain Plugs
13
17
D-Flange with Inpro/Seal (ADV+)
12
16
Drain Holes DE (No Threads/Breather Drains)
13
17
Inpro/Seal DE
12
16
Drain Holes NDE (No Threads/Breather Drains)
13
17
Inpro/Seal NDE
12
16
Tropicalization - Fungus/Corrosion Protection
13
17
Special Inpro/Seal DE (ADV+ 841)
12
16
Change Rotation
13
17
Special Inpro/Seal NDE (ADV+ 841)
12
16
Change Cooling Fan (Fan Not Included)
13
17
Protech Seal DE (ADV+ 841)
12
16
Jacking Bolts
13
17
Protech NDE (ADV+ 841)
12
16
Drip Cover
13
17
F2 Conversion
12
16
Drip Cover C/W Vertical Lifting Lugs
13
17
Space Heaters (CSA Certified)
12
16
Sun-Shield
13
17
Thermister 1/PH
12
16
Vibration Test & Report as Per IEEE841
13
17
Klixons 1/PH
12
16
Balance Rotor to IEEE841 Standards
13
17
Auxiliary Box
12
16
Shaft Grounding Brush (Carbon Type)
13
18
Auxiliary Box F2 Side
12
16
Shaft Ground Ring
13
18
Insulated NDE Bearing
12
16
Shaft Ground Seal (ADV+)
13
18
Stainless Steel Hardware
12
16
Special Paint - Color (Standard Paint)
13
18
Winding RTD 2/PH
12
16
Special Paint - Epoxy
13
18
Winding RTD 1/PH
12
16
Convert to 3 Lead Motor
13
18
Bearing RTD 1/BRG
12
16
Extend Main Leads
13
18
RTD Auxiliary Box
12
16
Change Bearings to ZZ Type
13
18
RTD Auxiliary Box F2 Side
12
16
De-Rate HP
13
18
Remove Feet
12
17
Re-Rate to 50HZ
13
18
Oversized Terminal Box - STD
12
17
Low Temp -50°C
13
18
Oversized Terminal Box - TYPE II
12
17
Convert IEEE Ready to IEEE 841
14
18
Terminal Block Main Terminal Box
12
17
Convert Standard TEFC to IEEE 841
14
18
Convert Bearings: Ball to Roller
12
17
Locked DE BRG
14
18
Convert Bearings: Roller to Ball
12
17
Class H Insulation
14
18
Custom Shaft - Modify Existing Shaft
13
17
Connect Motor for WYE-Delta Starting
14
18
Vertical Lifting Lugs
14
18
Custom Shaft - Replace Existing Shaft
13
17
Stub Shaft for Shaft Mounted Encoders
13
17
SECTION
MODIFICATIONS
No.
Bearing Tables
B
Convert Bearings: Ball to Roller
15
Convert Bearings: Roller to Ball
15
Insulated NDE Bearing
Insulated NDE Bearing
15
Bearing Cross Reference Table
Bearing Cross Reference Table for Stock Motors
HAZARDOUS
LOCATION
MODIFICATION
PRODUCT
DESCRIPTION
SECTION
B
MODIFICATIONS
19
No.
DESCRIPTION
CSA Certified Division 1 Space Heaters
14
18
F2 Conversion XP
14
18
Install C-Flange XP
14
18
Nameplate Change Hazloc
14
18
Explosion Proof Adder (When Approved)
14
18
Modification & Description Index
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
3
CONTROL PRODUCT INDEX
PRODUCT
SECTION
CONTROLS
No.
TECO DRIVE PRODUCTS
FM50 Micro Drive
1
FM50 NEMA 4 Micro Drive
3
FM50 NEMA 4 Micro Drive with Operators
3
L510 Micro Drive
6
N3 NEMA 1 AC Drive
8
N3 NEMA 1 AC Drive - Peripherals
10
F510 Fan & Pump AC Drive
11
F510 Fan & Pump AC Drive - Peripherals
13
A510 Heavy Duty AC Drive
14
A510 Heavy Duty AC Drive - Peripherals
19
CONTROLS
SP2000 DRIVE PRODUCTS
C
SP2000 All Purpose Drive
20
SP2000 - Overload Selection Chart
21
SP2000 All Purpose Drive - Peripherals
25
SP2000 All Purpose Drive - Communication Peripherals
26
LOW AND MEDIUM VOLTAGE SOFT STARTS
VMX SERIES - Chassis Style Soft-Starter
27
VMX SERIES - Enclosures
29
VMX SERIES - Configured Soft-Starter Systems - Heavy Duty
30
VMX SERIES - Configured Soft-Starter Systems - Standard Duty
30
MVC PLUS SERIES - Medium Voltage Soft-Starter
33
MV Soft Starter Dimensions
35
MV Soft Starter - Across The Line Starters
35
HARMONIC MITIGATION PRODUCTS
MTE - Line/Load Reactors
36
MTE - dV/dT Filters
45
MTE - Sine Wave Filters
48
MTE - Matrix Harmonic Filters
52
PROGRAMMABLE LOGIC RELAYS / HMI
SG2 - Programmable Logic Relay / HMI
55
CUSTOMER SERVICE
Field Service and Start-Up Assistance
4
Control Product Index
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
57
INDUCTION MOTOR REFERENCE GUIDE INDEX
INDUCTION MOTOR REFERENCE GUIDE
PRODUCT
SECTION
INDUCTION MOTOR REFERENCE GUIDE
ENCLOSURE
Drip-Proof Enclosures
Totally Enclosed
Totally Enclosed Fan Cooled
Breather / Drains
Space Heaters
Rotating Shaft Seal
Sealed Leads
Explosion-Proof Design
Enclosures Summarized
Frame Size
Frame Suffix Letters
MECHANICAL CONSIDERATIONS
Motor Mounting
Foot Mountings
Angle Mountings
Flange Mountings
Vertical Mountings
Coupling Methods
Direct Drives
Belted Drives
1
1
1
1
1
1
1
2
2
3
3
3
4
4
4
4
4
4
4
Non-Standard Belt Applications
5
Belt Tension
5
5
5
5
7
7
7
8
Bearings
D
No.
Ball Bearings
Using Speed-torque Curves
Environment
High Ambient Temperature
Low Ambient Temperature
High Elevation
MOTOR DESIGNS
Horsepower Formula
Torque Terminology
NEMA Designs A, B, C
NEMA Design D
NEMA Design F
POWER SUPPLY
Full Load Current
Voltage
Locked Rotor Kva Code Letter
Rated Frequency and Number of Phases
50 Cycle Motors
8
9
10
11
12
13
13
13
14
14
Service Factor
MOTOR EFFICIENCY
Motor Efficiency
TWMI Energy Saving Example
STARTING METHODS
Starting Methods for Squirrel Cage Motors
Auto-Transformer
Resistor
Reactor
Effect of Reduced Voltage Starting
VFD DRIVEN MOTOR APPLICATIONS
Variable Speed Applications
Effects of Harmonics on Induction Motors
Motor Insulation System & Supply Voltage
14
15
15
15
16
16
16
16
18
18
18
Cable Length & Type
18
Motor Shaft Voltages & Bearing Currents
19
VFD Carrier Frequency Settings
19
VFD Application in Hazardous Locations
19
INSULATION
Insulation Types and Temperature Rise
Service Factor
FIELD SERVICE
Excessive Vibration
Excessive Noise
20
21
22
23
High Current
Running Hot
Bearing Failures
Motor Burned Out
USEFUL INFORMATION
Useful Information
Re-Lubrication Guidelines
Formulas
24
25
25
28
28
29
31
Induction Motor Reference Guide Index
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
5
TECO WESTINGHOUSE MOTORS (CANADA) INC.
Your Authorized TECO-Westinghouse Representative is:
Your Base Motor Multiplier is:
Your Base Controls Multiplier is:
Date:
6
TECO-Westinghouse Motors (Canada) Inc. - Your Representative
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
TAILORED DISCOUNT STRUCTURE
PRODUCT
MOTORS
MULTIPLIER
THREE PHASE TEFC
Rolled Steel TEFC
Optim® TEFC
Advantage Plus IEEE Ready
Advantage Plus IEEE 841
Advantage Plus Mine Duty
Optim® TEXP
Optim® Oilwell
MOTORS
MAX-HT
THREE PHASE ODP
Rolled Steel ODP
Optim® ODP
MEDIUM VOLTAGE
Global XPE
Global ODP
SINGLE PHASE
Farm Duty
PUMP MOTORS
Optim® JP
Optim® JM
Optim® VH
Tailored Discount Structure
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
7
TAILORED DISCOUNT STRUCTURE
PRODUCT
CONTROLS
TECO VFD Peripherals
TECO VFD's
CONTROLS
SP2000 PRODUCTS
VMX Low Voltage Soft Starters
MVC MV Soft Starters
MTE Reactors
MTE DVDT Filters:
MTE Sine Wave Filters
MTE Matrix Harmonic Filters
Programmable Logic Products
8
Tailored Discount Structure
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
MULTIPLIER
SELLING POLICY
Selling Policy TWMI 2500 (E) 05/13
Supersedes Selling Policy TWMI 2500 (E) 05/12
Definition
The term “Company” shall be deemed to include TECOWestinghouse Motors (Canada) Inc. and its affiliates as
the case may be.
Price Policy
List Prices and Discounts
Prices and discounts are subject to change without
notice prior to entry of order.
Price Adjustment
The contract price, excluding sales taxes and erection
and service is subject to the following condition:
The contract price is firm for shipments made within 12
months from the date of quotation by the Company.
Taxes
Where prices include Government taxes, they are in
accordance with the law and regulations in effect at
the date of the proposal or quotation. Such prices are
subject to increase or decrease to reflect changes in
taxes levied by Governments made prior to delivery of
the product.
Prices do not include Federal Sales Tax. Provincial and
municipal taxes, where applicable will be added to the
prices quoted.
Terms of Payment
All payments shall be in Canadian dollars. Unless
authorized differently on a specific negotiation, the
Company’s standard terms of payment will apply.
1. On orders under $250,000 in value – 100% net 30
days. No cash discount.
2. On orders $250,000 and over and/or with shipping
schedule exceeding 6 months, progress payments will
be required. The standard Company progress payments
are:
a) 10% of the contract price on receipt of order.
b) 10% of the contract price on submission of drawings.
c) 40% on completion of major components (stator
core, rotor core, motor frame).
d) 30% due on readiness to ship from the factory.
e) 10% of contract price 30 days from Bill of Lading.
In case partial shipments are made at different times,
pro-rated payments shall be made therefore.
If shipments of the product specified, or any material
part thereof, are delayed from any cause for which the
Purchaser is directly or indirectly responsible, the date
of completion of the product by the Company shall
be regarded as the date of shipment in determining
when payments for said products are to be made, and
the Company shall be entitled to receive reasonable
compensation for storing the completed product which
shall be held at the purchaser’s risk. Normally, the
Company will inform the Purchaser in writing of the date
of completion. The Purchaser agrees that should any
of the payments not be made to the Company when
due under the terms of the proposal, then a service
charge on such overdue payments shall be billed by the
Company and paid by the Purchaser at the current rate
determined by the Company until the price including
service charges, has been fully paid in cash, but this shall
not be construed as obligating the Company to grant
any extension of time in the terms of payment.
Credit Approval
Acceptance of a purchase order is subject to approval of
the Purchaser’s credit by the Company. Notwithstanding
such acceptance and/or approval, if in the Company’s
judgment the purchaser’s financial condition does not
at any time warrant the continuation of production of
shipment of the original terms, the Company reserves
the right to request payment in advance or other surety.
Minimum Billing
The minimum billing for any one order shall be $150 net.
Quotations
Unless specified in a proposal, written quotations
automatically expire thirty calendar days from like date
issued. Verbal quotations expire the same day they are
made unless confirmed in writing, whereupon they
expire thirty days from the date issued.
Shipping Policy
Factory Shipments
Unless otherwise stated, CIF Ocean Port of entry in
Canada. All other freight extra.
Warehouse Shipments / Normally Stocked Items
Shipping terms are F.O.B. point of shipment with freight
prepaid and allowed to first Canadian destination
serviced by a common carrier provided shipment is
greater than $5000. There will be one single Canadian
destination per shipment prepaid. If shipment value is
less than $5000 freight charges will be collect.
Delivery
Unless otherwise expressly agreed in writing, delivery
of the product will be made F.O.B. the Company’s
factory or warehouse. Delivery dates specified are
subject to prior sale of manufacturing and engineering
space and to the receipt of all information necessary to
allow maintenance of the Company’s engineering and
manufacturing schedules.
Loss or Damage in Transit
The Company does not hold itself responsible for any
loss, damage or pilferage sustained in transit, having
obtained “in good order” receipts from the carrier.
Claims of such character should be made promptly
against the carrier. If the Company is notified in
writing of such claims, it will lend assistance to secure
adjustment.
Shipment F.O.B. Destination
The Company agrees to deliver the product F.O.B.
Destination, the Purchaser shall examine the product as
soon as it is received and shall within ten days thereafter
give notice to the Company and shall notify the carrier of
any loss or damage sustained during transit, and further
in the case of any damage, the Purchaser shall request
an inspection of the Loss or Damage by a representative
of the delivering carrier and a copy of the carrier’s
Inspection Report shall be sent to the Company. If such
notice to the Company or to the delivering carrier is
not given, the product shall be deemed to have been
delivered in satisfactory condition and the price shall
become due and payable in full as agreed between the
Company and the Purchaser.
Warranty
Stock Motor Warranty
All TECO–Westinghouse brand stock motors sold by
TECO–Westinghouse Motors (Canada) Inc. are warranted
to be free of defects in material and workmanship for
a period of thirty-six (36) months from the date of sale
or in the case of Advantage Plus IEEE 841, five (5) years
from date of sale.
This warranty is conditioned upon the installation,
operation, and maintenance of the motors in accordance
with TECO- Westinghouse Motors (Canada) Inc.
recommendations or standard industry practice and
the motors have at all times been operating or used
under normal operating conditions for which they were
designed.
TECO–Westinghouse Motors (Canada) Inc. shall, at
its sole option and expense, either repair or replace,
F.O.B.TWMI warehouse, any such motor or part which is
defective within the warranty period.
In the event of a warranty claim, TECO–Westinghouse
Motors (Canada) Inc. must be notified promptly
following any motor failure. The motor shall be sent to
a TECO–Westinghouse Motors (Canada) Inc. authorized
service center for diagnosis on the cause of failure. If the
failure is due to defective material and/or workmanship,
TECO–Westinghouse Motors (Canada) Inc. will replace or
repair the defective motor or part.
The repair or replacement of defective material and
workmanship shall constitute complete fulfillment of
TECO–Westinghouse Motors (Canada) Inc. warranty
liability whether the warranty claims are based on
contract, tort (including negligence and strict liability),
or otherwise.
Controls Warranty
TWMI warrants Control Products for the period of one
year from the date of invoice to be of merchantable
quality, free from defects in material, workmanship and
design. Warranty is limited to the exchange or repair of
products. Warranty does not apply to the application
or installation of products, service, shipping or
transportation costs associated with return or exchange
of goods.
Packaged Solutions Warranty
TWMI warrants Control Products that are commissioned
by an authorized TWMI Service Representative for the
period of two years from the Commissioning Date to be
of merchantable quality, free from defects in material,
workmanship and design and that the products supplied
are suitable for the intended application. Warranty is
limited to the exchange or repair of products. Warranty
does not apply to installation of products, shipping or
transportation costs associated with return or exchange
of goods or to any subsequent service costs.
Warranty is conditioned upon the installation,
operation and maintenance of the Control Products
in accordance with TECO-Westinghouse (Canada) Inc.
recommendations or standard industry practices and
the Controls at all times being operated or used under
normal operating conditions for which they were
designed.
TECO-Westinghouse Motors (Canada) Inc. shall, at its sole
option and expense, either repair or replace, F.O.B.TWMI
warehouse, any such Control Product or part there of
which is defective within the warranty period.
In the event of a warranty claim, TECO-Westinghouse
Motors (Canada) Inc. must be notified promptly
following the Control Product failure. The Control
Product shall be sent prepaid to TECO-Westinghouse
Motors (Canada) Inc. authorized service center for
diagnosis on the cause of failure. If the cause of failure is
due to defective material, workmanship or design, TECOWestinghouse Motors (Canada) Inc. will replace or repair
the defective Control or Part.
(Continued ...)
Selling Policy
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
9
SELLING POLICY
Selling Policy TWMI 2500 (E) 05/13
Supersedes Selling Policy TWMI 2500 (E) 05/12
The repair or replacement of defective material and
workmanship shall constitute complete fulfillment of
TECO-Westinghouse Motors (Canada) Inc. warranty
liability whether the warranty claims are based on
contract, tort (including negligence and strict liability),
or otherwise.
Engineered Motor Warranty
Where the product sold by the Company is also
manufactured by the Company, the Company warrants
the product supplied hereunder to be of the kind
designated or specified. Unless otherwise expressly
agreed in writing, the company shall repair or replace
any defective part or parts, F.O.B. the Company’s plant,
warehouse, or its designated service facility, which prove
to be defective under normal and proper use within
(one) 1 year from the date of installation or eighteen
(18) months from date of shipment, whichever occurs
earlier, provided that the Purchaser gives the Company
immediate written notice of any such defect or defects.
On expiration of the Warranty period, any liability of the
Company shall terminate.
Where the product sold by the Company is not also
manufactured by the Company, it is the product of a
reputable manufacturer sold under that manufacturer’s
brand or trade name and the Company warrants that it
will fulfill the same warranty obligations as it receives
from the manufacturer.
These corrections will be made at the customer’s
expense if corrections required are due to storage
conditions.
3. That an affidavit certifying that the apparatus has
successfully passed the inspection and is in “as
shipped” condition be supplied to TWMI by the
customer. Failure to provide TWMI with the affidavit
certifying that the apparatus has passed inspection
and is in “as shipped” condition will result in voiding
the warranty.
B. Extending Operational Warranty:
Extended Operational Warranties are available per the
following:
Total Warranty Period (Months)
18
30
42
48
(12 operational)
(24 operational)
(24 operational)
(36 operational)
% Addition
0 (standard)
3%
5%
7%
Longer operational warranties are available, but must be
negotiated with TWMI.
The applicable Warranty expressed in this paragraph
constitutes the only Warranty of the Company and no
other warrant or condition, statutory or otherwise, shall
be implied.
Optional Warranties:
A. Deferred Warranty:
The standard warranty shall apply subject to the
following modification:
The total warranty period will be a period of one year
from date of initial operation but not in excess of the
total warranty period selected.
For the total warranty period desired, make the addition
from the table to the net price of each unit.
Total Warranty Period (Months)
18
30
36
42
48
54
60
(12 operational)
(12 operational)
(12 operational)
(12 operational)
(12 operational)
(12 operational)
(12 operational)
% Addition
0 (standard)
1%
2%
3%
4%
5%
6%
The deferred warranty is valid only if the following
conditions are complied with:
1. That within thirty days prior to initial operation, a
TWMI Service Engineer be hired by the customer
to thoroughly inspect the apparatus to ascertain
that the apparatus is in “as shipped” condition. This
inspection will include but not be limited to:
a) Meggar test of winding insulation.
b) Internal inspection to determine that the winding
has not been damaged and that the apparatus is
clean and dry.
c) Inspection of the bearings to determine they have
not been damaged and that there is no water in
the oil reservoirs.
d) External inspection to determine that no damage
has been done.
2. Make any corrections which this inspection shows
to be needed because the apparatus has been in
storage or standing idle.
10
THERE ARE NO OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY AND FITNESS FOR
PARTICULAR PURPOSE, AND ALL WARRANTIES
ARISING FROM COURSE OF DEALING AND USAGE
OF TRADE. UNDER NO CIRCUMSTANCES, SHALL
TECO-WESTINGHOUSE MOTORS (CANADA)
INC. BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, INCLUDING FREIGHT.
Title
The title to the product or any part thereof shall pass
from the Company as soon as all payments due have
been fully made in cash, except as otherwise expressly
stipulated herein. The said product shall be and
remain personal property, notwithstanding its mode
of attachment to realty or other property. If default is
made in any of the payments herein, the Company may
retain any partial payments which have been made, as
liquidated damages and the Company shall be entitled
to the immediate possession of the product and shall
be free to enter the premises where the product may
be located and remove it as the Company’s property,
without prejudice to the Company’s right to recover
any further expenses or damages the Company suffer
by reason of such non-payment. Notwithstanding the
terms hereof, risk will pass to the purchaser at point of
delivery.
Force Majeure
The Company shall not be responsible or liable for
any loss, damage, detention or delay caused by war,
invasion, insurrection, riot, the order of any civil or
military authority, or by fire, flood weather or to other
acts of the elements, breakdown, lockouts, strikes or
labor disputes, the failure of the Company’s suppliers
to meet their contractual obligations, or, without
limitations of the foregoing, any other cause beyond the
reasonable control of the Company and the receiving of
the product by the Purchaser shall constitute a waiver of
all claims for loss or damage due to delay.
Patents
The Company’s agrees that it will at its own expense
defend all actions or proceedings instituted against
the Purchaser and pay any award of damages assessed
against the Purchaser in such actions or proceedings,
Selling Policy
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
insofar as the same are based on any claim that the said
product or any part thereof constitutes an infringement
of any claim of a Canadian patent, other than a claim
occurring a process or a product thereof, provided the
Purchaser gives the Company immediate notice in
writing of the institution of the actions or proceedings
and permits the Company through its council to defend
the same and give the Company all needed information,
assistance and authority to enable the Company so
to do. In case such product is in such action held to
constitute infringement, and its use is enjoyed, the
Company, within a reasonable time, will either secure
for the Purchaser the right to continue using said
product by suspension of the injunction, by procuring
for the Purchaser a license or otherwise or will at its
own expense, replace such product with non-infringing
product or modify it so that it becomes non-infringing or
remove the said enjoined product and refund the sums
paid therefore.
Limitation of Liability
Notwithstanding any other provision in this Agreement
or any applicable statutory provisions, the Company
shall not be liable to the Purchaser for any special
or consequential or incidental or punitive damages
including but not limited to loss of profits or revenues,
loss off use of the equipment, loss of opportunities,
loss of goodwill, interruption of business, or down time
costs and in no event shall the aggregate liability of the
Company exceed the unit price of the defective product,
part or service on which the such liability is based. The
provisions of this article, and of all other sections of the
Agreement providing for limitation of or protection
against liability of the Company, shall also protect its
direct and indirect suppliers and its subcontractors and
shall apply to the full extent permitted by law and shall
survive the termination, cancellation or expiration of this
Agreement.
In the event any product, part or service sold by the
Company hereunder is the subject of a resale by the
Purchaser, Purchaser agrees to bind his customer to
provisions limiting the liability of Purchaser and its
suppliers and subcontractors which are the same
as the corresponding provisions of this Agreement
and Purchaser shall indemnify and save harmless the
Company from any claims, loss or damage arising
directly or indirectly from the Purchaser’s failure to do so.
Returned Material
The Company’s permission must be obtained before
returning any material whereupon it will furnish
shipping instructions and tags. Any material returned
without permission will be held at Purchaser’s risk and is
liable to non-acceptance or delay in approval of credit.
Only standard stocked product may be returned for
credit. When permission is granted for the return of
material, credit will be allowed for the invoiced price
less a restocking charge and less transportation charges.
Any cost incurred in putting the material in salable
condition shall be deducted from the allowed credit.
Cancellation or Changes
Any order may be canceled or altered by the Purchaser
only upon payment of reasonable charges based upon
expenses already incurred and commitments made by
the company with respect to the order.
Installation
The product shall be installed by and at the expense of
the Purchaser, unless otherwise expressly stipulated.
Special Packing
Catalogue prices include domestic packing only. Where
special packing is required, refer to the Company.
Special Testing
If witness or other tests are required, refer to the
Company.
STANDARD WARRANTY FOR STOCK MOTORS
All TECO–Westinghouse brand stock motors sold by TECO–Westinghouse Motors (Canada) Inc.
are warranted to be free of defects in material and workmanship for a period of 36 months from
the date of sale (Advantage Plus 5 Year Warranty - IEEE 841 only).
This warranty is conditioned upon the installation, operation, and maintenance of the motors
in accordance with TECO–Westinghouse Motors (Canada) Inc. recommendations or standard
industry practice and the motors have at all times been operating or used under normal
operating conditions for which they were designed.
TECO–Westinghouse Motors (Canada) Inc. shall, at its sole option and expense, either repair or
replace, F.O.B. TWMI warehouse, any such motor or part which is defective within the warranty
period.
In the event of a warranty claim, TECO–Westinghouse Motors (Canada) Inc. must be notified
promptly following any motor failure. The motor shall be sent to a TECO–Westinghouse Motors
(Canada) Inc. authorized service center for diagnosis on the cause of failure. If the failure is
due to defective material and/or workmanship, TECO–Westinghouse Motors (Canada) Inc. will
replace or repair the defective motor or part.
The repair or replacement of defective material and workmanship shall constitute complete
fulfillment of TECO–Westinghouse Motors (Canada) Inc. warranty liability whether the warranty
claims are based on contract, tort (including negligence and strict liability), or otherwise.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY
IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR PARTICULAR
PURPOSE, AND ALL WARRANTIES ARISING FROM COURSE OF DEALING AND
USAGE OF TRADE. UNDER NO CIRCUMSTANCES, SHALL TECO-WESTINGHOUSE
MOTORS (CANADA) INC. BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING FREIGHT.
ONLINE WARRANTY INSTRUCTIONS ARE AVAILABLE AT:
www.tecowestinghouse.ca/support/warranty
Standard Warranty for Stock Motors
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
11
STANDARD WARRANTY FOR CONTROLS
WARRANTY CONTROL PRODUCTS
TWMI warrants Control Products for the period of one year from the date of invoice to be of
merchantable quality, free from defects in material, workmanship and design. Warranty is
limited to the exchange or repair of products. Warranty does not apply to the application or
installation of products, service, shipping or transportation costs associated with return or
exchange of goods.
WARRANTY PACKAGED SOLUTIONS
TWMI warrants Control Products that are commissioned by an authorized TWMI Service
Representative for the period of two years from the Commissioning Date to be of merchantable
quality, free from defects in material, workmanship and design and that the products supplied
are suitable for the intended application. Warranty is limited to the exchange or repair of
products. Warranty does not apply to installation of products, shipping or transportation costs
associated with return or exchange of goods or to any subsequent service costs.
Warranty is conditioned upon the installation, operation and maintenance of the Control
Products in accordance with TECO-Westinghouse (Canada) Inc. recommendations or standard
industry practices and the Controls at all times being operated or used under normal operating
conditions for which they were designed.
TECO-Westinghouse Motors (Canada) Inc. shall, at its sole option and expense, either repair or
replace, F.O.B. TWMI warehouse, any such Control Product or part there of which is defective
within the warranty period.
In the event of a warranty claim, TECO-Westinghouse Motors (Canada) Inc. must be notified
promptly following the Control Product failure. The Control Product shall be sent prepaid to
TECO-Westinghouse Motors (Canada) Inc. authorized service center for diagnosis on the cause
of failure. If the cause of failure is due to defective material, workmanship or design, TECOWestinghouse Motors (Canada) Inc. will replace or repair the defective Control or Part.
The repair or replacement of defective material and workmanship shall constitute complete
fulfillment of TECO-Westinghouse Motors (Canada) Inc. warranty liability whether the warranty
claims are based on contract, tort (including negligence and strict liability), or otherwise.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY
IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR PARTICULAR
PURPOSE, AND ALL WARRANTIES ARISING FROM COURSE OF DEALING AND
USAGE OF TRADE. UNDER NO CIRCUMSTANCES, SHALL TECO-WESTINGHOUSE
MOTORS (CANADA) INC. BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING FREIGHT.
12
Standard Warranty for Controls
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL: ROLLED STEEL TEFC
TYPE:
AEGH
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Pumps
• Compressors
• HVAC Equipment
PRODUCT OVERVIEW
• 1/4-10HP
• Totally Enclosed Fan Cooled IP44 Design
• 60Hz, 230/460V (Usable on 208V), or 575V
• Horizontal F1 Mount
• 3600, 1800 & 1200 RPM
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F.
• Class B Temperature Rise
• Continuous Duty
• 40˚C Ambient
• Class F Insulation
• Max Elevation 3300ft
• NEMA Design B
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings
• Multemp SRL Grease
• Dynamically Balanced Die-Cast Aluminum Rotor
• Rolled Steel Frame with Cast-Iron End Brackets
• Rolled Steel Conduit Box; 90 Degree Rotatable, Oversized and Gasketed
• Number of Leads 230/460V: 9 Leads 1/4-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Plastic Fan
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Rubber Flinger on DE
• *HPE™ High Pulse Endurance Spike Resistant Wire
• Phenolic Alkyd Resin Varnish
• Bi-Directional Rotation
• 56 Frame Available 1/4-3HP
OTHER FEATURES
• CSA Certified, UL recognized and CE marked
• *Meets NEMA MG1 Part 31.4.4.2
• CSA Energy Efficiency Verification (EEV)
• *Inverter Duty Speed Range 10:1 CT and 20:1 V
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
Motor Products - ROLLED STEEL TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A-1
LIST PRICES
PREMIUM EFFICIENCY TEFC
NEMA Standard 3-Phase Motors
60Hz, 230/460V (Usable on 208V)
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A-2
TYPE: AEGH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
RF0012
RF0014
RF0016
AEGH
AEGH
AEGH
1
1
1
3600
1800
1200
230/460V
230/460V
230/460V
143T
143T
145T
1.37
1.45
1.72
80.0
85.5
82.5
29
36
37
281
268
321
RF1/52
RF1/54
RF1/56
AEGH
AEGH
AEGH
1.5
1.5
1.5
3600
1800
1200
230/460V
230/460V
230/460V
143T
145T
182T
1.98
2.02
2.92
85.5
86.5
87.5
29
40
65
301
294
359
RF0022
RF0024
RF0026
AEGH
AEGH
AEGH
2
2
2
3600
1800
1200
230/460V
230/460V
230/460V
145T
145T
184T
2.55
2.74
3.28
86.5
86.5
88.5
36
40
84
334
326
413
RF0032
RF0034
RF0036
AEGH
AEGH
AEGH
3
3
3
3600
1800
1200
230/460V
230/460V
230/460V
182T
182T
213T
3.67
4.24
4.62
87.5
89.5
89.5
73
60
126
367
367
614
RF0052
RF0054
RF0056
AEGH
AEGH
AEGH
5
5
5
3600
1800
1200
230/460V
230/460V
230/460V
184T
184T
215T
5.81
6.54
7.06
89.5
89.5
90.2
84
82
164
446
425
737
RF7/52
RF7/54
AEGH
AEGH
7.5
7.5
3600
1800
230/460V
230/460V
213T
213T
9.21
9.23
90.2
91.7
123
117
609
610
RF0102
RF0104
AEGH
AEGH
10
10
3600
1800
230/460V
230/460V
215T
215T
12.0
12.0
91.0
91.7
162
159
721
734
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ROLLED STEEL TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEGH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
RF00125
RF00145
RF00165
AEGH
AEGH
AEGH
1
1
1
3600
1800
1200
575V
575V
575V
143T
143T
145T
1.10
1.16
1.38
80.0
85.5
82.5
29
36
37
281
268
321
RF1/525
RF1/545
RF1/565
AEGH
AEGH
AEGH
1.5
1.5
1.5
3600
1800
1200
575V
575V
575V
143T
145T
182T
1.58
1.61
2.33
85.5
86.5
87.5
29
40
65
301
294
359
RF00225
RF00245
RF00265
AEGH
AEGH
AEGH
2
2
2
3600
1800
1200
575V
575V
575V
145T
145T
184T
2.04
2.19
2.62
86.5
86.5
88.5
36
40
84
334
326
413
RF00325
RF00345
RF00365
AEGH
AEGH
AEGH
3
3
3
3600
1800
1200
575V
575V
575V
182T
182T
213T
2.94
3.39
3.69
87.5
89.5
89.5
73
60
126
367
367
614
RF00525
RF00545
RF00565
AEGH
AEGH
AEGH
5
5
5
3600
1800
1200
575V
575V
575V
184T
184T
215T
4.65
5.23
5.65
89.5
89.5
90.2
84
82
164
446
425
737
RF7/525
RF7/545
AEGH
AEGH
7.5
7.5
3600
1800
575V
575V
213T
213T
7.37
7.38
90.2
91.7
123
117
609
610
RF01025
RF01045
AEGH
AEGH
10
10
3600
1800
575V
575V
215T
215T
9.57
9.61
91.0
91.7
162
159
721
734
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ROLLED STEEL TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A-3
FEATURES
MODEL: OPTIM® TEFC
TYPE:
AEHH8N, AEHE
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Crushers
• Mixers
• Pumps
• Compressor
• Conveyors
PRODUCT OVERVIEW
• 1-800HP
• Totally Enclosed Fan Cooled IP54 Design, IP55 for 5000 Frames and Larger
• 60Hz, 230/460V (Usable on 208V), 460V or 575V
• Horizontal F1 Mount
• 3600, 1800, 1200 & 900 RPM
• *NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B or C
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames
280TS, 320T and Larger
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Dynamically Balanced Die-Cast Aluminum Rotor up to 449T Frames; Copper/Copper Alloy 5000 and Larger
• Cast-Iron Frame and End Brackets
• Cast-Iron Conduit Box up to 449T Frames; Fabricated Steel Conduit Box 5000 Frames and Larger, Gasketed, F1 Mounting
• Non-Sparking Plastic Fan up to 449T 4,6 & 8 Pole Motors; Bronze Fan 440TS 2 Pole Motors; Aluminum Fan 5000 Frames and Larger
• Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 6 Leads 150 and Above
• Number of Leads 575V: 3 Leads up to 449T; 6 Leads 5000 Frames and Larger
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box, Additional Grounding Terminal on Frame for 5000 Frames and Larger
• Interchangeable F1 and F2 mounting up to 449T
• Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Insulated NDE Bearing Standard for 600HP and larger 2 Pole motors
• Rubber Flinger on DE up to 280T; Steel Flinger on Both Ends 280TS and Larger
• **HPE™ High Pulse Endurance Spike Resistant Wire
• 2 Dips Phenolic Alkyd Resin Varnish 140T-440T, 2 Dips Epoxy Resin 5000 Frames and Larger; Spray Enamel Top Coat on all Frames
• Bi-Directional Rotation Except 3600RPM Motors 5000 Frames and Larger Which are CW From NDE
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger
OTHER FEATURES
• *CSA Certified for Class I, Division II, Groups B, C and D and
Class I, Zone 2, Groups IIB+H2, IIB and IIA
• **Inverter Duty Speed Range 10:1 CT and 20:1 VT up to 300HP; 3:1 CT
and 20:1 VT 301-600HP
• **Meets NEMA MG1 Part 31.4.4.2
• ABS Type Certified (5000 Frames and Larger)
* Applies to 1-600HP Only
** Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
A-4
Motor Products - OPTIM® TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHE, AEHH8N
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
PDH0012
PDH0014
PDH0016
PDH0018
AEHH8N
AEHH8N
AEHH8N
AEHE
1
1
1
1
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
143T
143T
145T
182T
1.34
1.50
1.73
2.08
82.5
85.5
82.5
77.0
46
46
62
95
341
297
361
573
PDH1/52
PDH1/54
PDH1/56
PDH1/58
AEHH8N
AEHH8N
AEHH8N
AEHE
1.5
1.5
1.5
1.5
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
143T
145T
182T
184T
2.00
2.08
2.53
3.01
84.0
86.5
87.5
77.0
46
62
84
114
355
329
401
619
PDH0022
PDH0024
PDH0026
PDH0028
AEHH8N
AEHH8N
AEHH8N
AEHE
2
2
2
2
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
145T
145T
184T
213T
2.52
2.78
3.00
3.42
86.5
86.5
88.5
85.5
62
62
101
167
375
362
453
702
PDH0032
PDH0034
PDH0036
PDH0038
AEHH8N
AEHH8N
AEHH8N
AEHE
3
3
3
3
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
182T
182T
213T
215T
3.53
3.74
4.02
4.98
88.5
89.5
89.5
85.5
84
84
167
189
433
407
612
807
PDH0052
PDH0054
PDH0056
PDH0058
AEHH8N
AEHH8N
AEHH8N
AEHE
5
5
5
5
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
184T
184T
215T
254T
5.72
6.12
6.24
7.52
88.5
89.5
91.0
86.5
101
101
194
288
504
477
807
1,098
PDH7/52
PDH7/54
PDH7/56
PDH7/58
AEHH8N
AEHH8N
AEHH8N
AEHE
7.5
7.5
7.5
7.5
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
213T
213T
254T
256T
8.67
8.85
9.59
11.5
91.0
91.7
91.0
85.5
167
167
297
332
667
671
1,084
1,451
PDH0102
PDH0104
PDH0106
PDH0108
AEHH8N
AEHH8N
AEHH8N
AEHE
10
10
10
10
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
215T
215T
256T
284T
11.5
11.6
12.8
14.2
91.0
91.7
91.0
89.5
194
194
337
429
795
811
1,344
1,962
PDH0152
PDH0154
PDH0156
PDH0158
AEHH8N
AEHH8N
AEHH8N
AEHE
15
15
15
15
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
254T
254T
284T
286T
16.6
17.3
18.2
20.1
92.4
92.4
92.4
89.5
297
297
418
475
1,053
1,096
1,778
2,422
PDH0202
PDH0204
PDH0206
PDH0208
AEHH8N
AEHH8N
AEHH8N
AEHE
20
20
20
20
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
256T
256T
286T
324T
21.9
23.0
24.3
25.6
92.4
93.0
91.7
90.2
337
337
475
664
1,426
1,342
2,207
3,027
PDH0252
PDH0254
PDH0256
PDH0258
AEHH8N
AEHH8N
AEHH8N
AEHE
25
25
25
25
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
284TS
284T
324T
326T
27.8
29.1
30.3
32.6
92.4
93.6
93.0
90.2
394
418
638
724
1,786
1,703
2,734
3,496
PDH0302
PDH0304
PDH0306
PDH0308
AEHH8N
AEHH8N
AEHH8N
AEHE
30
30
30
30
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
286TS
286T
326T
364T
33.2
34.3
37.5
39.0
93.0
93.6
93.0
93.0
444
475
675
898
2,079
1,978
3,347
4,480
(1)
(2)
(3)
(4)
(5)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated (460V).
For 50Hz, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A-5
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A-6
TYPE: AEHE, AEHH8N
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
PDH0402
PDH0404
PDH0406
PDH0408
AEHH8N
AEHH8N
AEHH8N
AEHE
40
40
40
40
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
324TS
324T
364T
365T
44.2
46.3
46.0
53.4
94.1
94.1
94.1
91.7
616
638
834
928
2,761
2,713
4,432
5,629
PDH0502
PDH0504
PDH0506
PDH0508
AEHH8N
AEHH8N
AEHH8N
AEHE
50
50
50
50
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
326TS
326T
365T
404T
54.7
56.9
57.8
62.5
94.1
94.5
94.1
93.0
638
675
913
1166
3,607
3,255
5,174
6,571
PDH0602
PDH0604
PDH0606
PDH0608
AEHH8N
AEHH8N
AEHH8N
AEHE
60
60
60
60
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
364TS
364T
404T
405T
64.2
68.4
68.3
74.6
94.1
95.0
94.5
93.0
759
834
1166
1298
4,781
4,321
5,968
7,596
PDH0752
PDH0754
PDH0756
PDH0758
AEHH8N
AEHH8N
AEHH8N
AEHE
75
75
75
75
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
365TS
365T
405T
444T
79.9
85.1
85.9
95.6
94.5
95.4
94.5
93.0
818
913
1298
1600
6,002
5,795
7,137
9,861
PDH1002
PDH1004
PDH1006
PDH1008
AEHH8N
AEHH8N
AEHH8N
AEHE
100
100
100
100
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
405TS
405T
444T
445T
107
112
119
127
95.4
95.4
95.0
93.0
1144
1298
1600
1800
8,061
7,481
9,974
13,589
PDH1252
PDH1254
PDH1256
PDH1258
AEHH8N
AEHH8N
AEHH8N
AEHE
125
125
125
125
3600
1800
1200
900
230/460V
230/460V
230/460V
230/460V
444TS
444T
445T
447T
143
146
148
156
95.0
95.4
95.0
93.6
1600
1600
1700
2450
10,685
9,591
12,208
16,247
PDH1502
PDH1504
PDH1506
PDH1508
AEHH8N
AEHH8N
AEHH8N
AEHE
150
150
150
150
3600
1800
1200
900
460V
460V
460V
460V
445TS
445T
447T
449T
170
175
176
188
95.0
95.8
95.8
93.6
1700
1780
2170
2800
12,439
10,814
13,959
19,371
PDH2002
PDH2004
PDH2006
PDH2008
PDH2008L
AEHH8N
AEHH8N
AEHH8N
AEHE
AEHE
200
200
200
200
200
3600
1800
1200
900
900
460V
460V
460V
460V
460V
447TS
447T
449T
449T
5007B
226
230
233
249
249
95.4
96.2
95.8
94.0
94.0
1900
2220
2450
3200
3200
16,044
13,550
16,950
21,993
27,172
PDH2502
PDH2504
PDH2506
PDH2508
AEHH8N
AEHH8N
AEHH8N
AEHE
250
250
250
250
3600
1800
1200
900
460V
460V
460V
460V
449TS
449T
449T
5009B
278
285
289
306
95.8
96.2
95.8
93.5
2320
2450
2560
4100
19,731
16,984
20,333
30,625
PDH3002
PDH3004
PDH3006
PDH3006L
PDH3008
AEHH8N
AEHH8N
AEHH8N
AEHH8N
AEHE
300
300
300
300
300
3600
1800
1200
1200
900
460V
460V
460V
460V
460V
449TS
449T
449T
5009B
5009B
333
342
347
339
366
95.8
96.2
95.8
95.8
94.6
2550
2560
2600
3950
4200
24,033
21,353
24,258
28,786
32,832
(1)
(2)
(3)
(4)
(5)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated (460V).
For 50Hz, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHE, AEHH8N
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
PDH3502
PDH3502L
PDH3504
PDH3504L
PDH3506
PDH3508
AEHH8N
AEHH8N
AEHH8N
AEHH8N
AEHH8N
AEHE
350
350
350
350
350
350
3600
3600
1800
1800
1200
900
460V
460V
460V
460V
460V
460V
449TS
5009A
449T
5009B
5011B
5011B
373
399
379
393
426
95.8
96.2
96.2
95.8
94.8
3300
2700
3500
4650
4800
27,891
31,887
24,250
27,449
33,553
37,567
PDH4002
PDH4004
PDH4006
PDH4008
AEHH8N
AEHH8N
AEHH8N
AEHE
400
400
400
400
3600
1800
1200
900
460V
460V
460V
460V
5009A
5009B
5011B
5808B
427
433
449
478
95.8
96.2
95.8
94.8
3450
3700
4900
5100
33,009
29,229
38,001
47,640
PDH4502
PDH4504
PDH4506
PDH4508
AEHH8N
AEHH8N
AEHH8N
AEHE
450
450
450
450
3600
1800
1200
900
460V
460V
460V
460V
5011A
5011B
5808B
5808B
480
487
500
537
95.8
96.2
95.8
95.0
4200
4800
5250
5450
37,229
34,401
43,788
50,382
PDH5002
PDH5004
PDH5006
PDH5008
AEHH8N
AEHH8N
AEHH8N
AEHE
500
500
500
500
3600
1800
1200
900
460V
460V
460V
460V
5011A
5011B
5808B
5810B
533
541
555
596
95.8
96.2
95.8
95.2
4600
5000
5600
6000
39,866
38,224
47,462
55,709
PDH6002
PDH6004
PDH6006
PDH6008
AEHE
AEHE
AEHE
AEHE
600
600
600
600
3600
1800
1200
900
460V
460V
460V
460V
5810A
5808B
5810B
6808B
650
654
677
700
95.4
95.5
95.6
95.5
6000
5800
6400
8050
46,793
45,192
53,621
65,715
PDH7002
PDH7004
PDH7006
PDH7008
AEHE
AEHE
AEHE
AEHE
700
700
700
700
3600
1800
1200
900
460V
460V
460V
460V
5810A
5810B
5810B
6808B
758
762
788
816
95.5
95.6
95.8
95.6
6600
6800
6900
8500
53,083
52,074
62,016
73,339
PDH8004
PDH8006
PDH8008
AEHE
AEHE
AEHE
800
800
800
1800
1200
900
460V
460V
460V
5810B
6808B
6808B
866
897
933
95.6
96.0
95.6
7250
8000
8850
59,002
71,341
76,830
(1)
(2)
(3)
(4)
(5)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated (460V).
For 50Hz, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM®TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A-7
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A-8
TYPE: AEHE, AEHH8N
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
PDH00125
PDH00145
PDH00165
PDH00185
AEHH8N
AEHH8N
AEHH8N
AEHE
1
1
1
1
3600
1800
1200
900
575V
575V
575V
575V
143T
143T
145T
182T
1.07
1.20
1.38
1.66
82.5
85.5
82.5
77.0
46
46
62
95
341
297
361
573
PDH1/525
PDH1/545
PDH1/565
PDH1/585
AEHH8N
AEHH8N
AEHH8N
AEHE
1.5
1.5
1.5
1.5
3600
1800
1200
900
575V
575V
575V
575V
143T
145T
182T
184T
1.60
1.66
2.02
2.41
84.0
86.5
87.5
77.0
46
62
84
114
355
329
401
619
PDH00225
PDH00245
PDH00265
PDH00285
AEHH8N
AEHH8N
AEHH8N
AEHE
2
2
2
2
3600
1800
1200
900
575V
575V
575V
575V
145T
145T
184T
213T
2.02
2.22
2.40
2.74
86.5
86.5
88.5
85.5
62
62
101
167
375
362
453
702
PDH00325
PDH00345
PDH00365
PDH00385
AEHH8N
AEHH8N
AEHH8N
AEHE
3
3
3
3
3600
1800
1200
900
575V
575V
575V
575V
182T
182T
213T
215T
2.82
2.99
3.22
3.98
88.5
89.5
89.5
85.5
84
84
167
189
433
407
612
807
PDH00525
PDH00545
PDH00565
PDH00585
AEHH8N
AEHH8N
AEHH8N
AEHE
5
5
5
5
3600
1800
1200
900
575V
575V
575V
575V
184T
184T
215T
254T
4.58
4.90
4.99
6.02
88.5
89.5
91.0
86.5
101
101
194
288
504
477
807
1,098
PDH7/525
PDH7/545
PDH7/565
PDH7/585
AEHH8N
AEHH8N
AEHH8N
AEHE
7.5
7.5
7.5
7.5
3600
1800
1200
900
575V
575V
575V
575V
213T
213T
254T
256T
6.94
7.08
7.67
9.20
91.0
91.7
91.0
85.5
167
167
297
332
667
671
1,084
1,451
PDH01025
PDH01045
PDH01065
PDH01085
AEHH8N
AEHH8N
AEHH8N
AEHE
10
10
10
10
3600
1800
1200
900
575V
575V
575V
575V
215T
215T
256T
284T
9.20
9.28
10.2
11.4
91.0
91.7
91.0
89.5
194
194
337
429
795
811
1,344
1,962
PDH01525
PDH01545
PDH01565
PDH01585
AEHH8N
AEHH8N
AEHH8N
AEHE
15
15
15
15
3600
1800
1200
900
575V
575V
575V
575V
254T
254T
284T
286T
13.3
13.8
14.6
16.1
92.4
92.4
92.4
89.5
297
297
418
475
1,053
1,096
1,778
2,422
PDH02025
PDH02045
PDH02065
PDH02085
AEHH8N
AEHH8N
AEHH8N
AEHE
20
20
20
20
3600
1800
1200
900
575V
575V
575V
575V
256T
256T
286T
324T
17.5
18.4
19.4
20.5
92.4
93.0
91.7
90.2
337
337
475
664
1,426
1,342
2,207
3,027
PDH02525
PDH02545
PDH02565
PDH02585
AEHH8N
AEHH8N
AEHH8N
AEHE
25
25
25
25
3600
1800
1200
900
575V
575V
575V
575V
284TS
284T
324T
326T
22.2
23.3
24.2
26.1
92.4
93.6
93.0
90.2
394
418
638
724
1,786
1,703
2,734
3,496
PDH03025
PDH03045
PDH03065
PDH03085
AEHH8N
AEHH8N
AEHH8N
AEHE
30
30
30
30
3600
1800
1200
900
575V
575V
575V
575V
286TS
286T
326T
364T
26.6
27.4
30.0
31.2
93.0
93.6
93.0
93.0
444
475
675
898
2,079
1,978
3,347
4,480
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For 50Hz, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHE, AEHH8N
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
PDH04025
PDH04045
PDH04065
PDH04085
AEHH8N
AEHH8N
AEHH8N
AEHE
40
40
40
40
3600
1800
1200
900
575V
575V
575V
575V
324TS
324T
364T
365T
35.4
37.0
36.8
42.7
94.1
94.1
94.1
91.7
616
638
834
928
2,761
2,713
4,432
5,629
PDH05025
PDH05045
PDH05065
PDH05085
AEHH8N
AEHH8N
AEHH8N
AEHE
50
50
50
50
3600
1800
1200
900
575V
575V
575V
575V
326TS
326T
365T
404T
43.8
45.5
46.2
50.0
94.1
94.5
94.1
93.0
638
675
913
1166
3,607
3,255
5,174
6,571
PDH06025
PDH06045
PDH06065
PDH06085
AEHH8N
AEHH8N
AEHH8N
AEHE
60
60
60
60
3600
1800
1200
900
575V
575V
575V
575V
364TS
364T
404T
405T
51.4
54.7
54.6
59.7
94.1
95.0
94.5
93.0
759
834
1166
1298
4,781
4,321
5,968
7,596
PDH07525
PDH07545
PDH07565
PDH07585
AEHH8N
AEHH8N
AEHH8N
AEHE
75
75
75
75
3600
1800
1200
900
575V
575V
575V
575V
365TS
365T
405T
444T
63.9
68.1
68.7
76.5
94.5
95.4
94.5
93.0
818
913
1298
1600
6,002
5,795
7,137
9,861
PDH10025
PDH10045
PDH10065
PDH10085
AEHH8N
AEHH8N
AEHH8N
AEHE
100
100
100
100
3600
1800
1200
900
575V
575V
575V
575V
405TS
405T
444T
445T
85.6
89.6
95.2
102
95.4
95.4
94.1
93.0
1144
1298
1600
1800
8,061
7,481
9,974
13,589
PDH12525
PDH12545
PDH12565
PDH12585
AEHH8N
AEHH8N
AEHH8N
AEHE
125
125
125
125
3600
1800
1200
900
575V
575V
575V
575V
444TS
444T
445T
447T
114
117
118
125
94.1
94.5
94.1
93.6
1600
1600
1700
2450
10,685
9,591
12,208
16,247
PDH15025
PDH15045
PDH15065
PDH15085
AEHH8N
AEHH8N
AEHH8N
AEHE
150
150
150
150
3600
1800
1200
900
575V
575V
575V
575V
445TS
445T
447T
449T
136
140
141
150
94.1
95.0
95.0
93.6
1700
1780
2170
2800
12,439
10,814
13,959
19,371
PDH20025
PDH20045
PDH20065
PDH20085
PDH20085L
AEHH8N
AEHH8N
AEHH8N
AEHE
AEHE
200
200
200
200
200
3600
1800
1200
900
900
575V
575V
575V
575V
575V
447TS
447T
449T
449T
5007B
181
184
186
199
199
94.5
95.4
95.0
94.0
94.0
1900
2220
2450
3200
3200
16,044
13,550
16,950
21,993
27,172
PDH25025
PDH25045
PDH25065
PDH25085
AEHH8N
AEHH8N
AEHH8N
AEHE
250
250
250
250
3600
1800
1200
900
575V
575V
575V
575V
449TS
449T
449T
5009B
222
228
231
245
95.0
95.4
95.0
94.5
2320
2450
2560
4100
19,731
16,984
20,333
30,625
PDH30025
PDH30045
PDH30065
PDH30065L
PDH30085
AEHH8N
AEHH8N
AEHH8N
AEHH8N
AEHE
300
300
300
300
300
3600
1800
1200
1200
900
575V
575V
575V
575V
575V
449TS
449T
449T
5009B
5009B
266
274
278
271
293
95.0
95.4
95.8
95.8
94.6
2550
2560
2600
3950
4200
24,033
21,353
24,258
28,786
32,832
PDH35025
PDH35025L
PDH35045
PDH35045L
PDH35065
PDH35085
AEHH8N
AEHH8N
AEHH8N
AEHH8N
AEHH8N
AEHE
350
350
350
350
350
350
3600
3600
1800
1800
1200
900
575V
575V
575V
575V
575V
575V
449TS
5009A
449T
5009B
5011B
5011B
298
319
303
314
341
95.8
96.2
95.5
95.0
94.8
3300
2700
3500
4650
4800
27,891
31,887
24,250
27,449
33,553
37,567
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For 50Hz, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A-9
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 10
TYPE: AEHE, AEHH8N
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
PDH40025
PDH40045
PDH40065
PDH40085
AEHH8N
AEHH8N
AEHH8N
AEHE
400
400
400
400
3600
1800
1200
900
575V
575V
575V
575V
5009A
5009B
5011B
5808B
342
346
359
382
95.0
95.5
95.0
94.8
3450
3700
4900
5100
33,009
29,229
38,001
47,640
PDH45025
PDH45045
PDH45065
PDH45085
AEHH8N
AEHH8N
AEHH8N
AEHE
450
450
450
450
3600
1800
1200
900
575V
575V
575V
575V
5011A
5011B
5808B
5808B
384
390
400
430
95.0
95.5
95.0
95.0
4200
4800
5250
5450
37,229
34,401
43,788
50,382
PDH50025
PDH50045
PDH50065
PDH50085
AEHH8N
AEHH8N
AEHH8N
AEHE
500
500
500
500
3600
1800
1200
900
575V
575V
575V
575V
5011A
5011B
5808B
5810B
426
433
444
477
95.0
95.5
95.0
95.2
4600
5000
5600
6000
39,866
38,224
47,462
55,709
PDH60025
PDH60045
PDH60065
PDH60085
AEHE
AEHE
AEHE
AEHE
600
600
600
600
3600
1800
1200
900
575V
575V
575V
575V
5810A
5808B
5810B
6808B
520
523
542
560
95.4
95.5
95.6
95.5
6000
5800
6400
8050
46,793
45,192
53,621
65,715
PDH70025
PDH70045
PDH70065
PDH70085
AEHE
AEHE
AEHE
AEHE
700
700
700
700
3600
1800
1200
900
575V
575V
575V
575V
5810A
5810B
5810B
6808B
606
610
630
653
95.5
95.6
95.8
95.6
6600
6800
6900
8500
53,083
52,074
62,016
73,339
PDH80045
PDH80065
PDH80085
AEHE
AEHE
AEHE
800
800
800
1800
1200
900
575V
575V
575V
5810B
6808B
6808B
693
718
746
95.6
96.0
95.6
7250
8000
8850
59,002
71,341
76,830
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For 50Hz, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® TEFC
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
IEEE READY
MODEL: ADVANTAGE PLUS IEEE READY
TYPE:
AEHH8R
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Compressors
• Pumps
• Mixers
• Crushers
• Conveyors
• Any Severe Duty / Petro-Chemical / Pulp & Paper Applications
PRODUCT OVERVIEW
• 1-500HP
• 3600, 1800, 1200 & 900RPM
• Horizontal F1 Mount
• 60Hz, 460V or 575V
• Totally Enclosed IP54 Design
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class B Temperature Rise
• Max Elevation 3300ft
• Continuous Duty
• 40˚C Ambient
• Class F Insulation
• Sound Pressure Level Complies with IEEE 841
• NEMA Design B or C
• Bearing Temperature Rise Below 45°C for 4P and 6P ratings; 50°C for 2P Motors
MECHANICAL FEATURES
• Oversized Open C3 Clearance Bearings with Regreaseable Provisions
• Polyrex EM Grease
• Dynamically Balanced Die-Cast Aluminum Rotor up to 449T Frames; Copper/Copper Alloy 5000 and Larger
• Cast-Iron Frame and End Brackets with Grease Provisions and Bearing Caps
• Frame Provided with Two Threaded Drain Holes and Stainless Steel Breather Drains
• Cast-Iron Conduit Box up to 449T Frames; Fabricated Steel Conduit Box 5000 Frames and Larger, Gasketed, F1 Mounting
• Non-Sparking Plastic Fan up to 449T 4,6 & 8 Pole Motors; Bronze Fan 440TS 2 Pole Motors and 5000 Frames and Larger
• Number of Leads 460V/575V: 3 Leads; Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and Provisions for Grounding Terminal on Motor Frame
• Interchangeable F1 and F2 mounting up to 449T
• Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below
• Paint System: Zinc Chromate Epoxy Primer, Phenolic Rust Proof Base with Lacquer Top Coat; All Internal Surfaces are Coated with
Moisture Resistant Varnish
• Stainless Steel Nameplate and Hardware
• Rubber Flinger on DE up to 280T; Copper Flinger on Both Ends 280TS and Larger
• *HPE™ High Pulse Endurance Spike Resistant Wire
• 2 Dips Phenolic Alkyd Resin Varnish with Red Varnish Spray on Both Ends
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger
OTHER FEATURES
• CSA Certified for Class I, Division II, Groups B, C and D and Class I, Zone 2, Groups IIB+H2, IIB and IIA
• *Inverter Duty Speed Range 10:1 CT and 20:1 VT up to 300HP; 3:1 CT and 20:1 VT 301-500HP
• *Meets NEMA MG1 Part 31.4.4.2
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 11
LIST PRICES
IEEE READY
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 12
TYPE: AEHH8R
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH0012
APH0014
APH0016
APH0018
AEHH8R
AEHH8R
AEHH8R
AEHH8R
1
1
1
1
3600
1800
1200
900
460V
460V
460V
460V
143T
143T
145T
182T
1.34
1.50
1.73
2.08
82.5
85.5
82.5
77.0
46
46
62
95
368
341
414
757
APH1/52
APH1/54
APH1/56
APH1/58
AEHH8R
AEHH8R
AEHH8R
AEHH8R
1.5
1.5
1.5
1.5
3600
1800
1200
900
460V
460V
460V
460V
143T
145T
182T
184T
2.00
2.08
2.53
3.01
84.0
86.5
87.5
77.0
46
62
84
114
368
382
459
846
APH0022
APH0024
APH0026
APH0028
AEHH8R
AEHH8R
AEHH8R
AEHH8R
2
2
2
2
3600
1800
1200
900
460V
460V
460V
460V
145T
145T
184T
213T
2.52
2.78
3.00
3.42
86.5
86.5
88.5
85.5
62
62
101
167
395
424
527
992
APH0032
APH0034
APH0036
APH0038
AEHH8R
AEHH8R
AEHH8R
AEHH8R
3
3
3
3
3600
1800
1200
900
460V
460V
460V
460V
182T
182T
213T
215T
3.53
3.74
4.02
4.98
88.5
89.5
89.5
85.5
84
84
167
189
463
477
683
1,298
APH0052
APH0054
APH0056
APH0058
AEHH8R
AEHH8R
AEHH8R
AEHH8R
5
5
5
5
3600
1800
1200
900
460V
460V
460V
460V
184T
184T
215T
254T
5.72
6.12
6.24
7.52
88.5
89.5
91.0
86.5
101
101
194
288
586
551
939
1,555
APH7/52
APH7/54
APH7/56
APH7/58
AEHH8R
AEHH8R
AEHH8R
AEHH8R
7.5
7.5
7.5
7.5
3600
1800
1200
900
460V
460V
460V
460V
213T
213T
254T
256T
8.67
8.85
9.59
11.5
91.0
91.7
91.0
85.5
167
167
297
332
739
747
1,227
2,236
APH0102
APH0104
APH0106
APH0108
AEHH8R
AEHH8R
AEHH8R
AEHH8R
10
10
10
10
3600
1800
1200
900
460V
460V
460V
460V
215T
215T
256T
284T
11.5
11.6
12.8
14.2
91.0
91.7
91.0
89.5
194
194
337
429
878
901
1,520
2,586
APH0152
APH0154
APH0156
APH0158
AEHH8R
AEHH8R
AEHH8R
AEHH8R
15
15
15
15
3600
1800
1200
900
460V
460V
460V
460V
254T
254T
284T
286T
16.6
17.3
18.2
20.1
92.4
92.4
92.4
89.5
297
297
418
475
1,208
1,208
2,057
3,518
APH0202
APH0204
APH0206
APH0208
AEHH8R
AEHH8R
AEHH8R
AEHH8R
20
20
20
20
3600
1800
1200
900
460V
460V
460V
460V
256T
256T
286T
324T
21.9
23.0
24.3
25.6
92.4
93.0
91.7
90.2
337
337
475
664
1,537
1,520
2,448
3,932
APH0252
APH0254
APH0256
APH0258
AEHH8R
AEHH8R
AEHH8R
AEHH8R
25
25
25
25
3600
1800
1200
900
460V
460V
460V
460V
284TS
284T
324T
326T
27.8
29.1
30.3
32.6
92.4
93.6
93.0
90.2
394
418
638
724
1,908
1,863
3,108
4,804
APH0302
APH0304
APH0306
APH0308
AEHH8R
AEHH8R
AEHH8R
AEHH8R
30
30
30
30
3600
1800
1200
900
460V
460V
460V
460V
286TS
286T
326T
364T
33.2
34.3
37.5
39.0
93.0
93.6
93.0
93.0
444
475
675
898
2,248
2,203
3,685
5,085
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
IEEE READY
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8R
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH0402
APH0404
APH0406
APH0408
AEHH8R
AEHH8R
AEHH8R
AEHH8R
40
40
40
40
3600
1800
1200
900
460V
460V
460V
460V
324TS
324T
364T
365T
44.2
46.3
46.0
53.4
94.1
94.1
94.1
91.7
616
638
834
928
2,956
2,942
4,938
7,597
APH0502
APH0504
APH0506
APH0508
AEHH8R
AEHH8R
AEHH8R
AEHH8R
50
50
50
50
3600
1800
1200
900
460V
460V
460V
460V
326TS
326T
365T
404T
54.7
56.9
57.8
62.5
94.1
94.5
94.1
93.0
638
675
913
1166
4,008
3,600
5,748
8,912
APH0602
APH0604
APH0606
APH0608
AEHH8R
AEHH8R
AEHH8R
AEHH8R
60
60
60
60
3600
1800
1200
900
460V
460V
460V
460V
364TS
364T
404T
405T
64.2
68.4
68.3
74.6
94.1
95.0
94.5
93.0
759
834
1166
1298
5,312
5,214
6,631
9,775
APH0752
APH0754
APH0756
APH0758
AEHH8R
AEHH8R
AEHH8R
AEHH8R
75
75
75
75
3600
1800
1200
900
460V
460V
460V
460V
365TS
365T
405T
444T
79.9
85.1
85.9
95.6
94.5
95.4
94.5
93.0
818
913
1298
1600
6,669
6,439
7,930
10,889
APH1002
APH1004
APH1006
APH1008
AEHH8R
AEHH8R
AEHH8R
AEHH8R
100
100
100
100
3600
1800
1200
900
460V
460V
460V
460V
405TS
405T
444T
445T
107
112
119
127
95.4
95.4
95.0
93.0
1144
1298
1600
1800
8,957
8,312
11,081
13,762
APH1252
APH1254
APH1256
APH1258
AEHH8R
AEHH8R
AEHH8R
AEHH8R
125
125
125
125
3600
1800
1200
900
460V
460V
460V
460V
444TS
444T
445T
447T
143
146
148
156
95.0
95.4
95.0
93.6
1600
1600
1700
2450
11,872
10,657
13,563
17,420
APH1502
APH1504
APH1506
APH1508
AEHH8R
AEHH8R
AEHH8R
AEHH8R
150
150
150
150
3600
1800
1200
900
460V
460V
460V
460V
445TS
445T
447T
449T
170
175
176
188
95.0
95.8
95.8
93.6
1700
1780
2170
2800
13,822
12,016
16,030
21,393
APH2002
APH2004
APH2006
APH2008
AEHH8R
AEHH8R
AEHH8R
AEHH8R
200
200
200
200
3600
1800
1200
900
460V
460V
460V
460V
447TS
447T
449T
449T
226
230
233
249
95.4
96.2
95.8
94.0
1900
2220
2450
3200
17,827
15,054
20,781
23,484
APH2502
APH2504
APH2506
APH2508
AEHH8R
AEHH8R
AEHH8R
AEHH8R
250
250
250
250
3600
1800
1200
900
460V
460V
460V
460V
449TS
449T
449T
5009B
278
285
289
306
95.8
96.2
95.8
93.5
2320
2450
2560
4100
21,923
19,647
25,111
43,116
APH3002
APH3004
APH3006
APH3006L
APH3008
AEHH8R
AEHH8R
AEHH8R
AEHH8R
AEHH8R
300
300
300
300
300
3600
1800
1200
1200
900
460V
460V
460V
460V
460V
449TS
449T
449T
5009B
5009B
333
342
347
339
366
95.8
96.2
95.8
95.8
94.6
2550
2560
2600
3950
4200
29,105
24,618
29,783
38,734
45,413
APH3502
APH3502L
APH3504
APH3504L
APH3506
APH3508
AEHH8R
AEHH8R
AEHH8R
AEHH8R
AEHH8R
AEHH8R
350
350
350
350
350
350
3600
3600
1800
1800
1200
900
460V
460V
460V
460V
460V
460V
449TS
5009A
449TS
5009B
5011B
5011B
373
399
379
393
426
95.8
96.2
96.2
95.8
94.8
3300
2700
3500
4650
4800
TBA
41,863
31,425
37,387
45,031
53,156
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 13
LIST PRICES
IEEE READY
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 14
TYPE: AEHH8R
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH4002
APH4004
APH4006
APH4008
AEHH8R
AEHH8R
AEHH8R
AEHH8R
400
400
400
400
3600
1800
1200
900
460V
460V
460V
460V
5009A
5009B
5011B
5808B
427
433
449
478
95.8
96.2
95.8
94.8
3450
3700
4900
5100
44,675
40,674
49,982
65,269
APH4502
APH4504
APH4506
APH4508
AEHH8R
AEHH8R
AEHH8R
AEHH8R
450
450
450
450
3600
1800
1200
900
460V
460V
460V
460V
5011A
5011B
5808B
5808B
480
487
500
537
95.8
96.2
95.8
95.0
4200
4800
5250
5450
48,992
45,942
58,576
68,334
APH5002
APH5004
APH5006
APH5008
AEHH8R
AEHH8R
AEHH8R
AEHH8R
500
500
500
500
3600
1800
1200
900
460V
460V
460V
460V
5011A
5011B
5808B
5810B
533
541
555
596
95.8
96.2
95.8
95.2
4600
5000
5600
6000
52,596
50,179
61,586
74,294
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
IEEE READY
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8R
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH00125
APH00145
APH00165
APH00185
AEHH8R
AEHH8R
AEHH8R
AEHH8R
1
1
1
1
3600
1800
1200
900
575V
575V
575V
575V
143T
143T
145T
182T
1.07
1.20
1.38
1.66
82.5
85.5
82.5
77.0
46
46
62
95
368
341
414
757
APH1/525
APH1/545
APH1/565
APH1/585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
1.5
1.5
1.5
1.5
3600
1800
1200
900
575V
575V
575V
575V
143T
145T
182T
184T
1.60
1.66
2.02
2.41
84.0
86.5
87.5
77.0
46
62
84
114
368
382
459
846
APH00225
APH00245
APH00265
APH00285
AEHH8R
AEHH8R
AEHH8R
AEHH8R
2
2
2
2
3600
1800
1200
900
575V
575V
575V
575V
145T
145T
184T
213T
2.02
2.22
2.40
2.74
86.5
86.5
88.5
85.5
62
62
101
167
395
424
527
992
APH00325
APH00345
APH00365
APH00385
AEHH8R
AEHH8R
AEHH8R
AEHH8R
3
3
3
3
3600
1800
1200
900
575V
575V
575V
575V
182T
182T
213T
215T
2.82
2.99
3.22
3.98
88.5
89.5
89.5
85.5
84
84
167
189
463
477
683
1,298
APH00525
APH00545
APH00565
APH00585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
5
5
5
5
3600
1800
1200
900
575V
575V
575V
575V
184T
184T
215T
254T
4.58
4.90
4.99
6.02
88.5
89.5
91.0
86.5
101
101
194
288
586
551
939
1,555
APH7/525
APH7/545
APH7/565
APH7/585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
7.5
7.5
7.5
7.5
3600
1800
1200
900
575V
575V
575V
575V
213T
213T
254T
256T
6.94
7.08
7.67
9.20
91.0
91.7
91.0
85.5
167
167
297
332
739
747
1,227
2,236
APH01025
APH01045
APH01065
APH01085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
10
10
10
10
3600
1800
1200
900
575V
575V
575V
575V
215T
215T
256T
284T
9.20
9.28
10.2
11.4
91.0
91.7
91.0
89.5
194
194
337
429
878
901
1,520
2,586
APH01525
APH01545
APH01565
APH01585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
15
15
15
15
3600
1800
1200
900
575V
575V
575V
575V
254T
254T
284T
286T
13.3
13.8
14.6
16.1
92.4
92.4
92.4
89.5
297
297
418
475
1,208
1,208
2,057
3,518
APH02025
APH02045
APH02065
APH02085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
20
20
20
20
3600
1800
1200
900
575V
575V
575V
575V
256T
256T
286T
324T
17.5
18.4
19.4
20.5
92.4
93.0
91.7
90.2
337
337
475
664
1,537
1,520
2,448
3,932
APH02525
APH02545
APH02565
APH02585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
25
25
25
25
3600
1800
1200
900
575V
575V
575V
575V
284TS
284T
324T
326T
22.2
23.3
24.2
26.1
92.4
93.6
93.0
90.2
394
418
638
724
1,908
1,863
3,108
4,804
APH03025
APH03045
APH03065
APH03085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
30
30
30
30
3600
1800
1200
900
575V
575V
575V
575V
286TS
286T
326T
364T
26.6
27.4
30.0
31.2
93.0
93.6
93.0
93.0
444
475
675
898
2,248
2,203
3,685
5,085
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 15
LIST PRICES
IEEE READY
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 16
TYPE: AEHH8R
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH04025
APH04045
APH04065
APH04085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
40
40
40
40
3600
1800
1200
900
575V
575V
575V
575V
324TS
324T
364T
365T
35.4
37.0
36.8
42.7
94.1
94.1
94.1
91.7
616
638
834
928
2,956
2,942
4,938
7,597
APH05025
APH05045
APH05065
APH05085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
50
50
50
50
3600
1800
1200
900
575V
575V
575V
575V
326TS
326T
365T
404T
43.8
45.5
46.2
50.0
94.1
94.5
94.1
93.0
638
675
913
1166
4,008
3,600
5,748
8,912
APH06025
APH06045
APH06065
APH06085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
60
60
60
60
3600
1800
1200
900
575V
575V
575V
575V
364TS
364T
404T
405T
51.4
54.7
54.6
59.7
94.1
95.0
94.5
93.0
759
834
1166
1298
5,312
5,214
6,631
9,775
APH07525
APH07545
APH07565
APH07585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
75
75
75
75
3600
1800
1200
900
575V
575V
575V
575V
365TS
365T
405T
444T
63.9
68.1
68.7
76.5
94.5
95.4
94.5
93.0
818
913
1298
1600
6,669
6,439
7,930
10,889
APH10025
APH10045
APH10065
APH10085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
100
100
100
100
3600
1800
1200
900
575V
575V
575V
575V
405TS
405T
444T
445T
85.6
89.6
95.2
102
95.4
95.4
94.1
93.0
1144
1298
1600
1800
8,957
8,312
11,081
13,762
APH12525
APH12545
APH12565
APH12585
AEHH8R
AEHH8R
AEHH8R
AEHH8R
125
125
125
125
3600
1800
1200
900
575V
575V
575V
575V
444TS
444T
445T
447T
114
117
118
125
94.1
94.5
94.1
93.6
1600
1600
1700
2450
11,872
10,657
13,563
17,420
APH15025
APH15045
APH15065
APH15085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
150
150
150
150
3600
1800
1200
900
575V
575V
575V
575V
445TS
445T
447T
449T
136
140
141
150
94.1
95.0
95.0
93.6
1700
1780
2170
2800
13,822
12,016
16,030
21,393
APH20025
APH20045
APH20065
APH20085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
200
200
200
200
3600
1800
1200
900
575V
575V
575V
575V
447TS
447T
449T
449T
181
184
186
199
94.5
95.4
95.0
94.0
1900
2220
2450
3200
17,827
15,054
20,781
23,484
APH25025
APH25045
APH25065
APH25085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
250
250
250
250
3600
1800
1200
900
575V
575V
575V
575V
449TS
449T
449T
5009B
222
228
231
245
95.0
95.4
95.0
94.5
2320
2450
2560
4100
21,923
19,647
25,111
43,116
APH30025
APH30045
APH30065
APH30065L
APH30085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
AEHH8R
300
300
300
300
300
3600
1800
1200
1200
900
575V
575V
575V
575V
575V
449TS
449T
449T
5009B
5009B
266
274
278
271
293
95.0
95.4
95.8
95.8
94.6
2550
2560
2600
3950
4200
29,105
24,618
29,783
38,734
45,413
APH35025
APH35025L
APH35045
APH35045L
APH35065
APH35085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
AEHH8R
AEHH8R
350
350
350
350
350
350
3600
3600
1800
1800
1200
900
575V
575V
575V
575V
575V
575V
449TS
5009A
449T
5009B
5011B
5011B
298
319
303
314
341
95.8
96.2
95.5
95.0
94.8
3300
2700
3500
4650
4800
TBA
41,863
31,425
37,387
45,031
53,156
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
IEEE READY
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8R
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH40025
APH40045
APH40065
APH40085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
400
400
400
400
3600
1800
1200
900
575V
575V
575V
575V
5009A
5009B
5011B
5808B
342
346
359
382
95.0
95.5
95.0
94.8
3450
3700
4900
5100
44,675
40,674
49,982
65,269
APH45025
APH45045
APH45065
APH45085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
450
450
450
450
3600
1800
1200
900
575V
575V
575V
575V
5011A
5011B
5808B
5808B
384
390
400
430
95.0
95.5
95.0
95.0
4200
4800
5250
5450
48,992
45,942
58,576
68,334
APH50025
APH50045
APH50065
APH50085
AEHH8R
AEHH8R
AEHH8R
AEHH8R
500
500
500
500
3600
1800
1200
900
575V
575V
575V
575V
5011A
5011B
5808B
5810B
426
433
444
477
95.0
95.5
95.0
95.2
4600
5000
5600
6000
52,596
50,179
61,586
74,294
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE READY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 17
FEATURES
IEEE 841
MODEL: ADVANTAGE PLUS IEEE 841
TYPE:
AEHH8B
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Compressors
• Pumps
• Mixers
• Crushers
• Conveyors
• Any Severe Duty / Petro-Chemical / Pulp & Paper Applications
PRODUCT OVERVIEW
• 1-500HP
• Horizontal F1 Mount
• 3600, 1800, 1200 & 900RPM
• 60Hz, 460V or 575V
• NEMA Premium Efficiency
• Totally Enclosed Fan Cooled IP55 Design
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• NEMA Design B or C
• 40˚C Ambient
• Continuous Duty
• Class B Temperature Rise
• Max Elevation 3300ft
• Class F Insulation
• Fully Compliant with IEEE 841 Standard
MECHANICAL FEATURES
• Oversized Open C3 Clearance Bearings with Regreaseable Provisions
• Polyrex EM Grease
• Dynamically Balanced Die-Cast Aluminum Rotor up to 449T Frames; Copper/Copper Alloy 5000 and Larger
• Vibration Signature Shipped with Motor
• Cast-Iron Frame and End Brackets with Grease Provisions and Bearing Caps
• Frame Provided with Two Threaded Drain Holes and Stainless Steel Breather Drains
• Cast-Iron Conduit Box up to 449T Frames; Fabricated Steel Conduit Box 5000 Frames and Larger, Gasketed, F1 Mounting
• Non-Sparking Plastic Fan up to 449T 4,6 & 8 Pole Motors; Bronze Fan 440TS 2 Pole Motors and 5000 Frames and Larger
• Number of Leads 460V/575V: 3 Leads; Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and Provisions for Grounding Terminal on Motor Frame
• Interchangeable F1 and F2 mounting up to 449T
• Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below
• Paint System: Zinc Chromate Epoxy Primer, Phenolic Rust Proof Base with Lacquer Top Coat; All Internal Surfaces are Coated with
Moisture Resistant Varnish
• Stainless Steel Nameplate and Hardware
• Inpro/Seal Bearing Isolator on DE and NDE
• *HPE™ High Pulse Endurance Spike Resistant Wire
• 2 Dips Phenolic Alkyd Resin Varnish with Red Varnish Spray on Both Ends
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger
OTHER FEATURES
• CSA Certified for Class I, Division II, Groups B, C and D and Class I, Zone 2, Groups IIB+H2, IIB and IIA
• *Inverter Duty Speed Range 10:1 CT and 20:1 VT up to 300HP; 3:1 CT and 20:1 VT 301-500HP
• Meets or Exceeds *NEMA MG1 Part 31.4.4.2; IEEE 45 Marine Duty 1 – 125HP; IEEE Std 841™-2009
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
A - 18
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
IEEE 841
PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8B
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH0012-841
APH0014-841
APH0016-841
APH0018-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
1
1
1
1
3600
1800
1200
900
460V
460V
460V
460V
143T
143T
145T
182T
1.34
1.50
1.73
2.08
82.5
85.5
82.5
77.0
46
46
62
95
638
604
732
937
APH1/52-841
APH1/54-841
APH1/56-841
APH1/58-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
1.5
1.5
1.5
1.5
3600
1800
1200
900
460V
460V
460V
460V
143T
145T
182T
184T
2.00
2.08
2.53
3.01
84.0
86.5
87.5
77.0
46
62
84
114
676
668
774
1,022
APH0022-841
APH0024-841
APH0026-841
APH0028-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
2
2
2
2
3600
1800
1200
900
460V
460V
460V
460V
145T
145T
184T
213T
2.52
2.78
3.00
3.42
86.5
86.5
88.5
85.5
62
62
101
167
719
706
867
1,354
APH0032-841
APH0034-841
APH0036-841
APH0038-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
3
3
3
3
3600
1800
1200
900
460V
460V
460V
460V
182T
182T
213T
215T
3.53
3.74
4.02
4.98
88.5
89.5
89.5
85.5
84
84
167
189
790
796
1,178
1,503
APH0052-841
APH0054-841
APH0056-841
APH0058-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
5
5
5
5
3600
1800
1200
900
460V
460V
460V
460V
184T
184T
215T
254T
5.72
6.12
6.24
7.52
88.5
89.5
91.0
86.5
101
101
194
288
901
883
1,439
2,024
APH7/52-841
APH7/54-841
APH7/56-841
APH7/58-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
7.5
7.5
7.5
7.5
3600
1800
1200
900
460V
460V
460V
460V
213T
213T
254T
256T
8.67
8.85
9.59
11.5
91.0
91.7
91.0
85.5
167
167
297
332
1,143
1,156
1,934
2,526
APH0102-841
APH0104-841
APH0106-841
APH0108-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
10
10
10
10
3600
1800
1200
900
460V
460V
460V
460V
215T
215T
256T
284T
11.5
11.6
12.8
14.2
91.0
91.7
91.0
89.5
194
194
337
429
1,265
1,285
2,182
3,046
APH0152-841
APH0154-841
APH0156-841
APH0158-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
15
15
15
15
3600
1800
1200
900
460V
460V
460V
460V
254T
254T
284T
286T
16.6
17.3
18.2
20.1
92.4
92.4
92.4
89.5
297
297
418
475
1,745
1,754
2,946
3,876
APH0202-841
APH0204-841
APH0206-841
APH0208-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
20
20
20
20
3600
1800
1200
900
460V
460V
460V
460V
256T
256T
286T
324T
21.9
23.0
24.3
25.6
92.4
93.0
91.7
90.2
337
337
475
664
2,283
2,224
3,571
4,389
APH0252-841
APH0254-841
APH0256-841
APH0258-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
25
25
25
25
3600
1800
1200
900
460V
460V
460V
460V
284TS
284T
324T
326T
27.8
29.1
30.3
32.6
92.4
93.6
93.0
90.2
394
418
638
724
2,732
2,533
3,920
5,221
APH0302-841
APH0304-841
APH0306-841
APH0308-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
30
30
30
30
3600
1800
1200
900
460V
460V
460V
460V
286TS
286T
326T
364T
33.2
34.3
37.5
39.0
93.0
93.6
93.0
93.0
444
475
675
898
3,047
2,804
4,302
6,713
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 19
LIST PRICES
IEEE 841
PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 20
TYPE: AEHH8B
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH0402-841
APH0404-841
APH0406-841
APH0408-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
40
40
40
40
3600
1800
1200
900
460V
460V
460V
460V
324TS
324T
364T
365T
44.2
46.3
46.0
53.4
94.1
94.1
94.1
91.7
616
638
834
928
3,589
3,457
5,821
8,428
APH0502-841
APH0504-841
APH0506-841
APH0508-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
50
50
50
50
3600
1800
1200
900
460V
460V
460V
460V
326TS
326T
365T
404T
54.7
56.9
57.8
62.5
94.1
94.5
94.1
93.0
638
675
913
1166
4,596
4,131
6,727
9,805
APH0602-841
APH0604-841
APH0606-841
APH0608-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
60
60
60
60
3600
1800
1200
900
460V
460V
460V
460V
364TS
364T
404T
405T
64.2
68.4
68.3
74.6
94.1
95.0
94.5
93.0
759
834
1166
1298
6,246
6,043
7,746
10,727
APH0752-841
APH0754-841
APH0756-841
APH0758-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
75
75
75
75
3600
1800
1200
900
460V
460V
460V
460V
365TS
365T
405T
444T
79.9
85.1
85.9
95.6
94.5
95.4
94.5
93.0
818
913
1298
1600
7,247
6,997
9,137
12,685
APH1002-841
APH1004-841
APH1006-841
APH1008-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
100
100
100
100
3600
1800
1200
900
460V
460V
460V
460V
405TS
405T
444T
445T
107
112
119
127
95.4
95.4
95.0
93.0
1144
1298
1600
1800
9,733
9,032
12,044
15,604
APH1252-841
APH1254-841
APH1256-841
APH1258-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
125
125
125
125
3600
1800
1200
900
460V
460V
460V
460V
444TS
444T
445T
447T
143
146
148
156
95.0
95.4
95.0
93.6
1600
1600
1700
2450
12,901
11,582
14,740
18,905
APH1502-841
APH1504-841
APH1506-841
APH1508-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
150
150
150
150
3600
1800
1200
900
460V
460V
460V
460V
445TS
445T
447T
449T
170
175
176
188
95.0
95.8
95.8
93.6
1700
1780
2170
2800
15,421
13,339
17,419
22,776
APH2002-841
APH2004-841
APH2006-841
APH2008-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
200
200
200
200
3600
1800
1200
900
460V
460V
460V
460V
447TS
447T
449T
449T
226
230
233
249
95.4
96.2
95.8
94.0
1900
2220
2450
3200
18,775
16,229
21,328
26,927
APH2502-841
APH2504-841
APH2506-841
APH2508-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
250
250
250
250
3600
1800
1200
900
460V
460V
460V
460V
449TS
449T
449T
5009B
278
285
289
306
95.8
96.2
95.8
93.5
2320
2450
2560
4100
22,501
20,164
26,385
41,227
APH3002-841
APH3004-841
APH3006-841
APH3006L-841
APH3008-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
AEHH8B
300
300
300
300
300
3600
1800
1200
1200
900
460V
460V
460V
460V
460V
449TS
449T
449T
5009B
5009B
333
342
347
339
366
95.8
96.2
95.8
95.8
94.6
2550
2560
2600
3950
4200
29,279
25,904
32,629
40,705
42,940
APH3502-841
APH3502L-841
APH3504-841
APH3504L-841
APH3506-841
APH3508-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
AEHH8B
AEHH8B
350
350
350
350
350
350
3600
3600
1800
1800
1200
900
460V
460V
460V
460V
460V
460V
449TS
5009A
449T
5009B
5011B
5011B
373
399
379
393
426
95.8
96.2
96.2
95.8
94.8
3300
2700
3500
4650
4800
TBA
43,442
33,445
39,078
46,531
51,032
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
IEEE 841
PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8B
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH4002-841
APH4004-841
APH4006-841
APH4008-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
400
400
400
400
3600
1800
1200
900
460V
460V
460V
460V
5009A
5009B
5011B
5808B
427
433
449
478
95.8
96.2
95.8
94.8
3450
3700
4900
5100
46,183
42,284
51,789
60,275
APH4502-841
APH4504-841
APH4506-841
APH4508-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
450
450
450
450
3600
1800
1200
900
460V
460V
460V
460V
5011A
5011B
5808B
5808B
480
487
500
537
95.8
96.2
95.8
95.0
4200
4800
5250
5450
51,668
47,419
59,737
65,823
APH5002-841
APH5004-841
APH5006-841
APH5008-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
500
500
500
500
3600
1800
1200
900
460V
460V
460V
460V
5011A
5011B
5808B
5810B
533
541
555
596
95.8
96.2
95.8
95.2
4600
5000
5600
6000
56,907
51,551
65,923
71,447
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 21
LIST PRICES
IEEE 841
PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 22
TYPE: AEHH8B
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH00125-841
APH00145-841
APH00165-841
APH00185-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
1
1
1
1
3600
1800
1200
900
575V
575V
575V
575V
143T
143T
145T
182T
1.07
1.20
1.38
1.66
82.5
85.5
82.5
77.0
46
46
62
95
638
604
732
937
APH1/525-841
APH1/545-841
APH1/565-841
APH1/585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
1.5
1.5
1.5
1.5
3600
1800
1200
900
575V
575V
575V
575V
143T
145T
182T
184T
1.60
1.66
2.02
2.41
84.0
86.5
87.5
77.0
46
62
84
114
676
668
774
1,022
APH00225-841
APH00245-841
APH00265-841
APH00285-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
2
2
2
2
3600
1800
1200
900
575V
575V
575V
575V
145T
145T
184T
213T
2.02
2.22
2.40
2.74
86.5
86.5
88.5
85.5
62
62
101
167
719
706
867
1,354
APH00325-841
APH00345-841
APH00365-841
APH00385-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
3
3
3
3
3600
1800
1200
900
575V
575V
575V
575V
182T
182T
213T
215T
2.82
2.99
3.22
3.98
88.5
89.5
89.5
85.5
84
84
167
189
790
796
1,178
1,503
APH00525-841
APH00545-841
APH00565-841
APH00585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
5
5
5
5
3600
1800
1200
900
575V
575V
575V
575V
184T
184T
215T
254T
4.58
4.90
4.99
6.02
88.5
89.5
91.0
86.5
101
101
194
288
901
883
1,439
2,024
APH7/525-841
APH7/545-841
APH7/565-841
APH7/585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
7.5
7.5
7.5
7.5
3600
1800
1200
900
575V
575V
575V
575V
213T
213T
254T
256T
6.94
7.08
7.67
9.20
91.0
91.7
91.0
85.5
167
167
297
332
1,143
1,156
1,934
2,526
APH01025-841
APH01045-841
APH01065-841
APH01085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
10
10
10
10
3600
1800
1200
900
575V
575V
575V
575V
215T
215T
256T
284T
9.20
9.28
10.2
11.4
91.0
91.7
91.0
89.5
194
194
337
429
1,265
1,285
2,182
3,046
APH01525-841
APH01545-841
APH01565-841
APH01585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
15
15
15
15
3600
1800
1200
900
575V
575V
575V
575V
254T
254T
284T
286T
13.3
13.8
14.6
16.1
92.4
92.4
92.4
89.5
297
297
418
475
1,745
1,754
2,946
3,876
APH02025-841
APH02045-841
APH02065-841
APH02085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
20
20
20
20
3600
1800
1200
900
575V
575V
575V
575V
256T
256T
286T
324T
17.5
18.4
19.4
20.5
92.4
93.0
91.7
90.2
337
337
475
664
2,283
2,224
3,571
4,389
APH02525-841
APH02545-841
APH02565-841
APH02585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
25
25
25
25
3600
1800
1200
900
575V
575V
575V
575V
284TS
284T
324T
326T
22.2
23.3
24.2
26.1
92.4
93.6
93.0
90.2
394
418
638
724
2,732
2,533
3,920
5,221
APH03025-841
APH03045-841
APH03065-841
APH03085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
30
30
30
30
3600
1800
1200
900
575V
575V
575V
575V
286TS
286T
326T
364T
26.6
27.4
30.0
31.2
93.0
93.6
93.0
93.0
444
475
675
898
3,047
2,804
4,302
6,713
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
IEEE 841
PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8B
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH04025-841
APH04045-841
APH04065-841
APH04085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
40
40
40
40
3600
1800
1200
900
575V
575V
575V
575V
324TS
324T
364T
365T
35.4
37.0
36.8
42.7
94.1
94.1
94.1
91.7
616
638
834
928
3,589
3,457
5,821
8,428
APH05025-841
APH05045-841
APH05065-841
APH05085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
50
50
50
50
3600
1800
1200
900
575V
575V
575V
575V
326TS
326T
365T
404T
43.8
45.5
46.2
50.0
94.1
94.5
94.1
93.0
638
675
913
1166
4,596
4,131
6,727
9,805
APH06025-841
APH06045-841
APH06065-841
APH06085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
60
60
60
60
3600
1800
1200
900
575V
575V
575V
575V
364TS
364T
404T
405T
51.4
54.7
54.6
59.7
94.1
95.0
94.5
93.0
759
834
1166
1298
6,246
6,043
7,746
10,727
APH07525-841
APH07545-841
APH07565-841
APH07585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
75
75
75
75
3600
1800
1200
900
575V
575V
575V
575V
365TS
365T
405T
444T
63.9
68.1
68.7
76.5
94.5
95.4
94.5
93.0
818
913
1298
1600
7,247
6,997
9,137
12,685
APH10025-841
APH10045-841
APH10065-841
APH10085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
100
100
100
100
3600
1800
1200
900
575V
575V
575V
575V
405TS
405T
444T
445T
85.6
89.6
95.2
102
95.4
95.4
94.1
93.0
1144
1298
1600
1800
9,733
9,032
12,044
15,604
APH12525-841
APH12545-841
APH12565-841
APH12585-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
125
125
125
125
3600
1800
1200
900
575V
575V
575V
575V
444TS
444T
445T
447T
114
117
118
125
94.1
94.5
94.1
93.6
1600
1600
1700
2450
12,901
11,582
14,740
18,905
APH15025-841
APH15045-841
APH15065-841
APH15085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
150
150
150
150
3600
1800
1200
900
575V
575V
575V
575V
445TS
445T
447T
449T
136
140
141
150
94.1
95.0
95.0
93.6
1700
1780
2170
2800
15,421
13,339
17,419
22,776
APH20025-841
APH20045-841
APH20065-841
APH20085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
200
200
200
200
3600
1800
1200
900
575V
575V
575V
575V
447TS
447T
449T
449T
181
184
186
199
94.5
95.4
95.0
94.0
1900
2220
2450
3200
18,775
16,229
21,328
26,927
APH25025-841
APH25045-841
APH25065-841
APH25085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
250
250
250
250
3600
1800
1200
900
575V
575V
575V
575V
449TS
449T
449T
5009B
222
228
231
245
95.0
95.4
95.0
94.5
2320
2450
2560
4100
22,501
20,164
26,385
41,227
APH30025-841
APH30045-841
APH30065-841
APH30065L-841
APH30085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
AEHH8B
300
300
300
300
300
3600
1800
1200
1200
900
575V
575V
575V
575V
575V
449TS
449T
449T
5009B
5009B
266
274
278
271
293
95.0
95.4
95.8
95.8
94.6
2550
2560
2600
3950
4200
29,279
25,904
32,629
40,705
42,940
APH35025-841
APH35025L-841
APH35045-841
APH35045L-841
APH35065-841
APH35085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
AEHH8B
AEHH8B
350
350
350
350
350
350
3600
3600
1800
1800
1200
900
575V
575V
575V
575V
575V
575V
449TS
5009A
449T
5009B
5011B
5011B
298
319
303
314
341
95.8
96.2
95.5
95.0
94.8
3300
2700
3500
4650
4800
TBA
43,442
33,445
39,078
46,531
51,032
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 23
LIST PRICES
IEEE 841
PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 24
TYPE: AEHH8B
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
APH40025-841
APH40045-841
APH40065-841
APH40085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
400
400
400
400
3600
1800
1200
900
575V
575V
575V
575V
5009A
5009B
5011B
5808B
342
346
359
382
95.0
95.5
95.0
94.8
3450
3700
4900
5100
46,183
42,284
51,789
60,275
APH45025-841
APH45045-841
APH45065-841
APH45085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
450
450
450
450
3600
1800
1200
900
575V
575V
575V
575V
5011A
5011B
5808B
5808B
384
390
400
430
95.0
95.5
95.0
95.0
4200
4800
5250
5450
51,668
47,419
59,737
65,823
APH50025-841
APH50045-841
APH50065-841
APH50085-841
AEHH8B
AEHH8B
AEHH8B
AEHH8B
500
500
500
500
3600
1800
1200
900
575V
575V
575V
575V
5011A
5011B
5808B
5810B
426
433
444
477
95.0
95.5
95.0
95.2
4600
5000
5600
6000
56,907
51,551
65,923
71,447
(1)
(2)
(3)
(4)
Prices subject to change without notice.
For ratings meeting NEMA Design C, please contact a TWMI representative.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS IEEE 841
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MINE DUTY
MODEL: ADVANTAGE PLUS MINE DUTY
TYPE:
AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Crushers
• Compressors
• Any Severe Duty / Petro-Chemical / Pulp & Paper Applications
• Pumps
• Conveyors
• Mixers
• Extreme Duty Mining Applications / Potash / Sulphur / Metals
PRODUCT OVERVIEW
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Horizontal F1 Mount
• 3600, 1800, 1200 & 900RPM
• 60Hz, 460V or 575V
• *NEMA Premium Efficiency
• Totally Enclosed Fan Cooled IP55 Design
DESIGN FEATURES
• 1.15 S.F. Sine Wave
Power; 1.0 S.F. VFD Power
• Class B
Temperature Rise
• NEMA Design B (Design C Available
Upon Request 100HP and Larger)
• Sound Pressure Level 80dBa @ 1M, Except
440TS 2 Pole and larger Which Meet 85 dBA
• Continuous Duty
• 40˚C Ambient
• Class F Insulation
• Max Elevation 3300ft
MECHANICAL FEATURES
• Oversized Open C3 Clearance Bearings with Regreaseable Provisions
• Polyrex EM Grease
• Dynamically Balanced Die-Cast Aluminum Rotor up to 449T Frames; Copper/Copper Alloy 5000 and Larger
• Cast-Iron Frame, Fan Cover and End Brackets with Grease Provisions and Bearing Caps; Fabricated Steel Fan Cover 5000 Frames
and Larger
• Frame Provided with Two Threaded Drain Holes and Stainless Steel Breather Drains
• Cast-Iron Conduit Box up to 449T, Fabricated steel terminal box for 5000 Frames and Larger
• Cast Iron or Bronze Fan up to 449T Frames; Aluminum Fan 5000 and Larger; All Fans Epoxy Coated
• Number of Leads 460V/575V: 3 Leads; Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and Provisions for Grounding Terminal on Motor Frame
• Interchangeable F1 and F2 mounting up to 449T
• Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below
• Paint System: Zinc Chromate Epoxy Primer, Phenolic Rust Proof Base with Green Lacquer Top Coat; All Internal Surfaces are Coated with
Corrosion Resistant Paint
• 316 Stainless Steel Nameplate and Hardware
• Loctite Anti-Seize Compound Applied to All Threads & Fan Bore
• Gasket Maker Silicone Applied to All Mating Surfaces with the Exception of the Terminal Box Cover
• INPRO/Seal Bearing Isolator on DE and NDE
• **HPE™ High Pulse Endurance Spike Resistant Wire
• 2 Dips Phenolic Alkyd Resin Varnish with Red Varnish Spray on Both Ends
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger
OTHER FEATURES
• **Inverter Duty Speed Range 10:1 CT and 20:1 VT up to 300HP; 3:1 CT and 20:1 VT 301-500HP
• **Meets NEMA MG1 Part 31.4.4.2
* Applies to Design B, and Select Design C Motors Only
** Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
Motor Products -ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 25
LIST PRICES
MINE DUTY
PREMIUM EFFICIENCY EXTREME DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 26
TYPE: AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
MD0012
MD0014
MD0016
MD0018
AEHH8M
AEHH8M
AEHH8M
AEHH8M
1
1
1
1
3600
1800
1200
900
460V
460V
460V
460V
143T
143T
145T
182T
1.34
1.50
1.73
2.08
82.5
85.5
82.5
77.0
46
46
62
84
741
729
819
1,049
MD1/52
MD1/54
MD1/56
MD1/58
AEHH8M
AEHH8M
AEHH8M
AEHH8M
1.5
1.5
1.5
1.5
3600
1800
1200
900
460V
460V
460V
460V
143T
145T
182T
184T
2.00
2.08
2.53
2.96
84.0
86.5
87.5
78.5
46
62
84
101
741
771
921
1,180
MD0022
MD0024
MD0026
MD0028
AEHH8M
AEHH8M
AEHH8M
AEHH8M
2
2
2
2
3600
1800
1200
900
460V
460V
460V
460V
145T
145T
184T
213T
2.52
2.78
3.00
3.48
86.5
86.5
88.5
84.0
62
62
101
167
753
777
1,046
1,561
MD0032
MD0034
MD0036
MD0038
AEHH8M
AEHH8M
AEHH8M
AEHH8M
3
3
3
3
3600
1800
1200
900
460V
460V
460V
460V
182T
182T
213T
215T
3.53
3.74
4.02
4.98
88.5
89.5
89.5
85.5
84
84
167
194
877
877
1,460
1,731
MD0052
MD0054
MD0056
MD0058
AEHH8M
AEHH8M
AEHH8M
AEHH8M
5
5
5
5
3600
1800
1200
900
460V
460V
460V
460V
184T
184T
215T
254T
5.72
6.12
6.24
7.52
88.5
89.5
91.0
86.5
101
101
194
297
1,020
987
1,562
2,262
MD7/52
MD7/54
MD7/56
MD7/58
AEHH8M
AEHH8M
AEHH8M
AEHH8M
7.5
7.5
7.5
7.5
3600
1800
1200
900
460V
460V
460V
460V
213T
213T
254T
256T
8.67
8.85
9.59
11.4
91.0
91.7
91.0
86.5
167
167
297
337
1,327
1,345
2,130
2,623
MD0102
MD0104
MD0106
MD0108
AEHH8M
AEHH8M
AEHH8M
AEHH8M
10
10
10
10
3600
1800
1200
900
460V
460V
460V
460V
215T
215T
256T
284T
11.5
11.6
12.8
14.2
91.0
91.7
91.0
89.5
194
194
337
418
1,424
1,439
2,464
3,414
MD0152
MD0154
MD0156
MD0158
AEHH8M
AEHH8M
AEHH8M
AEHH8M
15
15
15
15
3600
1800
1200
900
460V
460V
460V
460V
254T
254T
284T
286T
16.6
17.3
18.2
20.1
92.4
92.4
92.4
89.5
297
297
418
475
1,995
1,986
3,026
4,195
MD0202
MD0204
MD0206
MD0208
AEHH8M
AEHH8M
AEHH8M
AEHH8M
20
20
20
20
3600
1800
1200
900
460V
460V
460V
460V
256T
256T
286T
324T
21.9
23.0
24.3
25.6
92.4
93.0
91.7
90.2
337
337
475
638
2,384
2,348
3,648
4,831
MD0252
MD0254
MD0256
MD0258
AEHH8M
AEHH8M
AEHH8M
AEHH8M
25
25
25
25
3600
1800
1200
900
460V
460V
460V
460V
284TS
284T
324T
326T
27.8
29.1
30.3
32.6
92.4
93.6
93.0
90.2
394
418
638
675
2,816
2,779
4,477
5,448
MD0302
MD0304
MD0306
MD0308
AEHH8M
AEHH8M
AEHH8M
AEHH8M
30
30
30
30
3600
1800
1200
900
460V
460V
460V
460V
286TS
286T
326T
364T
33.2
34.3
37.5
39.5
93.0
93.6
93.0
91.7
444
475
675
834
2,995
2,995
4,902
7,713
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
MINE DUTY
PREMIUM EFFICIENCY EXTREME DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
MD0402
MD0404
MD0406
MD0408
AEHH8M
AEHH8M
AEHH8M
AEHH8M
40
40
40
40
3600
1800
1200
900
460V
460V
460V
460V
324TS
324T
364T
365T
44.2
46.3
46.0
53.4
94.1
94.1
94.1
91.7
616
638
834
913
4,156
4,032
7,426
9,473
MD0502
MD0504
MD0506
MD0508
AEHH8M
AEHH8M
AEHH8M
AEHH8M
50
50
50
50
3600
1800
1200
900
460V
460V
460V
460V
326TS
326T
365T
404T
54.7
56.9
57.9
62.5
94.1
94.5
94.1
93.0
638
675
913
1166
4,777
4,674
8,637
10,597
MD0602
MD0604
MD0606
MD0608
AEHH8M
AEHH8M
AEHH8M
AEHH8M
60
60
60
60
3600
1800
1200
900
460V
460V
460V
460V
364TS
364T
404T
405T
64.2
68.4
68.3
74.6
94.1
95.0
94.5
93.0
759
834
1166
1298
7,626
7,404
9,612
11,499
MD0752
MD0754
MD0756
MD0758
AEHH8M
AEHH8M
AEHH8M
AEJA8M
75
75
75
75
3600
1800
1200
900
460V
460V
460V
460V
365TS
365T
405T
444T
79.9
85.1
85.9
94.4
94.5
95.4
94.5
93.6
818
913
1298
1600
8,643
8,260
10,461
14,342
MD1002
MD1004
MD1006
MD1008
AEHH8M
AEHH8M
AEJA8M
AEJA8M
100
100
100
100
3600
1800
1200
900
460V
460V
460V
460V
405TS
405T
444T
445T
107
112
117
125
95.4
95.4
94.5
93.6
1144
1298
1550
1800
10,756
10,035
14,318
17,132
MD1252
MD1254
MD1256
MD1258
AEJA8M
AEJA8M
AEJA8M
AEJA8M
125
125
125
125
3600
1800
1200
900
460V
460V
460V
460V
444TS
444T
445T
447T
140
141
145
154
95.0
94.5
94.5
94.1
1450
1550
1900
2450
15,217
14,486
16,578
19,813
MD1502
MD1504
MD1506
MD1508
AEJA8M
AEJA8M
AEJA8M
AEJA8M
150
150
150
150
3600
1800
1200
900
460V
460V
460V
460V
445TS
445T
447T
449T
167
168
171
183
95.0
95.0
95.0
94.1
1550
1700
2200
2800
15,955
15,315
18,895
23,654
MD2002
MD2004
MD2006
MD2008
AEJA8M
AEJA8M
AEJA8M
AEJA8M
200
200
200
200
3600
1800
1200
900
460V
460V
460V
460V
447TS
447T
449T
449T
221
229
233
243
95.4
95.0
95.0
94.5
2150
2350
2650
3200
19,835
18,418
22,869
30,442
MD2502
MD2504
MD2506
MD2508
AEJA8M
AEJA8M
AEJA8M
AEJA8M
250
250
250
250
3600
1800
1200
900
460V
460V
460V
460V
449TS
449T
449T
5009B
271
276
289
310
95.8
95.4
95.0
94.5
2530
2650
3450
4000
25,002
21,677
29,625
51,260
MD3002
MD3004
MD3006
MD3008
AEJA8M
AEJA8M
AEJA8M
AEJA8M
300
300
300
300
3600
1800
1200
900
460V
460V
460V
460V
449TS
449T
5009B
5011B
326
333
348
367
95.8
95.4
95.0
94.5
2560
2680
3700
4850
31,932
27,717
49,238
53,613
MD3502
MD3504
MD3506
MD3508
AEJA8M
AEJA8M
AEJA8M
AEJA8M
350
350
350
350
3600
1800
1200
900
460V
460V
460V
460V
5009A
5009B
5011B
5808B
373
388
406
428
95.8
95.4
95.0
94.5
3300
3700
4600
5250
50,223
45,585
56,181
61,468
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 27
LIST PRICES
MINE DUTY
PREMIUM EFFICIENCY EXTREME DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 28
TYPE: AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
MD4002
MD4004
MD4006
MD4008
AEJA8M
AEJA8M
AEJA8M
AEJA8M
400
400
400
400
3600
1800
1200
900
460V
460V
460V
460V
5009A
5011B
5808B
5808B
427
441
461
487
95.8
95.4
95.0
95.0
3450
4200
5100
5550
53,192
49,043
61,632
72,177
MD4502
MD4504
MD4506
AEJA8M
AEJA8M
AEJA8M
450
450
450
3600
1800
1200
460V
460V
460V
5011A
5808B
5808B
480
493
517
95.8
95.4
95.4
4200
4850
5300
57,729
54,562
71,068
MD5002
MD5004
MD5006
AEJA8M
AEJA8M
AEJA8M
500
500
500
3600
1800
1200
460V
460V
460V
5011A
5808B
5808B
546
574
555
95.8
95.4
95.8
5300
5650
5600
61,533
59,019
74,426
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
MINE DUTY
PREMIUM EFFICIENCY EXTREME DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
MD00125
MD00145
MD00165
MD00185
AEHH8M
AEHH8M
AEHH8M
AEHH8M
1
1
1
1
3600
1800
1200
900
575V
575V
575V
575V
143T
143T
145T
182T
1.07
1.20
1.39
1.66
82.5
85.5
82.5
77.0
46
46
62
84
741
729
819
1,049
MD1/525
MD1/545
MD1/565
MD1/585
AEHH8M
AEHH8M
AEHH8M
AEHH8M
1.5
1.5
1.5
1.5
3600
1800
1200
900
575V
575V
575V
575V
143T
145T
182T
184T
1.60
1.67
2.02
2.37
84.0
86.5
87.5
78.5
46
62
84
101
741
771
921
1,180
MD00225
MD00245
MD00265
MD00285
AEHH8M
AEHH8M
AEHH8M
AEHH8M
2
2
2
2
3600
1800
1200
900
575V
575V
575V
575V
145T
145T
184T
213T
2.01
2.22
2.40
2.79
86.5
86.5
88.5
84.0
62
62
101
167
753
777
1,046
1,561
MD00325
MD00345
MD00365
MD00385
AEHH8M
AEHH8M
AEHH8M
AEHH8M
3
3
3
3
3600
1800
1200
900
575V
575V
575V
575V
182T
182T
213T
215T
2.82
2.99
3.22
3.98
88.5
89.5
89.5
85.5
84
84
167
194
877
877
1,460
1,731
MD00525
MD00545
MD00565
MD00585
AEHH8M
AEHH8M
AEHH8M
AEHH8M
5
5
5
5
3600
1800
1200
900
575V
575V
575V
575V
184T
184T
215T
254T
4.58
4.89
4.99
6.01
88.5
89.5
91.0
86.5
101
101
194
297
1,020
987
1,562
2,262
MD7/525
MD7/545
MD7/565
MD7/585
AEHH8M
AEHH8M
AEHH8M
AEHH8M
7.5
7.5
7.5
7.5
3600
1800
1200
900
575V
575V
575V
575V
213T
213T
254T
256T
6.94
7.08
7.67
9.1
91.0
91.7
91.0
86.5
167
167
297
337
1,327
1,345
2,130
2,623
MD01025
MD01045
MD01065
MD01085
AEHH8M
AEHH8M
AEHH8M
AEHH8M
10
10
10
10
3600
1800
1200
900
575V
575V
575V
575V
215T
215T
256T
284T
9.2
9.3
10.2
11.4
91.0
91.7
91.0
89.5
194
194
337
418
1,424
1,439
2,464
3,414
MD01525
MD01545
MD01565
MD01585
AEHH8M
AEHH8M
AEHH8M
AEHH8M
15
15
15
15
3600
1800
1200
900
575V
575V
575V
575V
254T
254T
284T
286T
13.3
13.8
14.6
16.1
92.4
92.4
92.4
89.5
297
297
418
475
1,995
1,986
3,026
4,195
MD02025
MD02045
MD02065
MD02085
AEHH8M
AEHH8M
AEHH8M
AEHH8M
20
20
20
20
3600
1800
1200
900
575V
575V
575V
575V
256T
256T
286T
324T
17.5
18.4
19.4
20.5
92.4
93.0
91.7
90.2
337
337
475
638
2,384
2,348
3,648
4,831
MD02525
MD02545
MD02565
MD02585
AEHH8M
AEHH8M
AEHH8M
AEHH8M
25
25
25
25
3600
1800
1200
900
575V
575V
575V
575V
284TS
284T
324T
326T
22.3
23.3
24.3
26.1
92.4
93.6
93.0
90.2
394
418
638
675
2,816
2,779
4,477
5,448
MD03025
MD03045
MD03065
MD03085
AEHH8M
AEHH8M
AEHH8M
AEHH8M
30
30
30
30
3600
1800
1200
900
575V
575V
575V
575V
286TS
286T
326T
364T
26.6
27.4
30.0
31.6
93.0
93.6
93.0
91.7
444
475
675
834
2,995
2,995
4,902
7,713
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 29
LIST PRICES
MINE DUTY
PREMIUM EFFICIENCY EXTREME DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 30
TYPE: AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
MD04025
MD04045
MD04065
MD04085
AEHH8M
AEHH8M
AEHH8M
AEHH8M
40
40
40
40
3600
1800
1200
900
575V
575V
575V
575V
324TS
324T
364T
365T
35.4
37.0
36.8
42.7
94.1
94.1
94.1
91.7
616
638
834
913
4,156
4,032
7,426
9,473
MD05025
MD05045
MD05065
MD05085
AEHH8M
AEHH8M
AEHH8M
AEHH8M
50
50
50
50
3600
1800
1200
900
575V
575V
575V
575V
326TS
326T
365T
404T
43.7
45.6
46.3
50.0
94.1
94.5
94.1
93.0
638
675
913
1166
4,777
4,674
8,637
10,597
MD06025
MD06045
MD06065
MD06085
AEHH8M
AEHH8M
AEHH8M
AEHH8M
60
60
60
60
3600
1800
1200
900
575V
575V
575V
575V
364TS
364T
404T
405T
51.4
54.7
54.7
59.7
94.1
95.0
94.5
93.0
759
834
1166
1298
7,626
7,404
9,612
11,499
MD07525
MD07545
MD07565
MD07585
AEHH8M
AEHH8M
AEHH8M
AEJA8M
75
75
75
75
3600
1800
1200
900
575V
575V
575V
575V
365TS
365T
405T
444T
63.9
68.1
68.7
75.5
94.5
95.4
94.5
93.6
818
913
1298
1600
8,643
8,260
10,461
14,342
MD10025
MD10045
MD10065
MD10085
AEHH8M
AEHH8M
AEJA8M
AEJA8M
100
100
100
100
3600
1800
1200
900
575V
575V
575V
575V
405TS
405T
444T
445T
85
90
94
100
95.4
95.4
94.5
93.6
1144
1298
1550
1800
10,756
10,035
14,318
17,132
MD12525
MD12545
MD12565
MD12585
AEJA8M
AEJA8M
AEJA8M
AEJA8M
125
125
125
125
3600
1800
1200
900
575V
575V
575V
575V
444TS
444T
445T
447T
112
113
116
123
95.0
94.5
94.5
94.1
1450
1550
1900
2450
15,217
14,486
16,578
19,813
MD15025
MD15045
MD15065
MD15085
AEJA8M
AEJA8M
AEJA8M
AEJA8M
150
150
150
150
3600
1800
1200
900
575V
575V
575V
575V
445TS
445T
447T
449T
134
134
137
146
95.0
95.0
95.0
94.1
1550
1700
2200
2800
15,955
15,315
18,895
23,654
MD20025
MD20045
MD20065
MD20085
AEJA8M
AEJA8M
AEJA8M
AEJA8M
200
200
200
200
3600
1800
1200
900
575V
575V
575V
575V
447TS
447T
449T
449T
177
183
186
194
95.4
95.0
95.0
94.5
2150
2350
2650
3200
19,835
18,418
22,869
30,442
MD25025
MD25045
MD25065
MD25085
AEJA8M
AEJA8M
AEJA8M
AEJA8M
250
250
250
250
3600
1800
1200
900
575V
575V
575V
575V
449TS
449T
449T
5009B
217
221
231
248
95.8
95.4
95.0
94.5
2530
2650
3450
4000
25,002
21,677
29,625
51,260
MD30025
MD30045
MD30065
MD30085
AEJA8M
AEJA8M
AEJA8M
AEJA8M
300
300
300
300
3600
1800
1200
900
575V
575V
575V
575V
449TS
449T
5009B
5011B
261
266
278
294
95.8
95.4
95.0
94.5
2560
2680
3700
4850
31,932
27,717
49,238
53,613
MD35025
MD35045
MD35065
MD35085
AEJA8M
AEJA8M
AEJA8M
AEJA8M
350
350
350
350
3600
1800
1200
900
575V
575V
575V
575V
5009A
5009B
5011B
5808B
298
310
325
342
95.8
95.4
95.0
94.5
3300
3700
4600
5250
50,223
45,585
56,181
61,468
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
MINE DUTY
PREMIUM EFFICIENCY EXTREME DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8M, AEJA8M
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
MD40025
MD40045
MD40065
MD40085
AEJA8M
AEJA8M
AEJA8M
AEJA8M
400
400
400
400
3600
1800
1200
900
575V
575V
575V
575V
5009A
5011B
5808B
5808B
342
353
369
390
95.8
95.4
95.0
95.0
3450
4200
5100
5550
53,192
49,043
61,632
72,177
MD45025
MD45045
MD45065
AEJA8M
AEJA8M
AEJA8M
450
450
450
3600
1800
1200
575V
575V
575V
5011A
5808B
5808B
384
394
414
95.8
95.4
95.4
4200
4850
5300
57,729
54,562
71,068
MD50025
MD50045
MD50065
AEJA8M
AEJA8M
AEJA8M
500
500
500
3600
1800
1200
575V
575V
575V
5011A
5808B
5808B
437
459
444
95.8
95.4
95.8
5300
5650
5600
61,533
59,019
74,426
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ADVANTAGE PLUS MINE DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 31
FEATURES
MODEL: OPTIM® TEXP
TYPE:
AEHHXU, AEHHXF, AEHHXV
Effective 04-10-14
Supercedes All Previous
APPLICATIONS
• Applications Where Explosive Gases are Present
• Grain Elevators
• Applications Where Explosive Dusts / Grains are Present
• Blowers
• Pumps
PRODUCT OVERVIEW
• 1-300HP
• Horizontal F1 Mount
• 60Hz, 230V/460V (Usable on 208V), 460V or 575V
• 3600, 1800, 1200 & 900 RPM
• NEMA Premium Efficiency
• Totally Enclosed Fan Cooled - Explosion Proof Design (IP54)
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B or C
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames
280TS, 320T and Larger
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame, Fan Cover and End Brackets
• Frame Provided with Two Threaded Drain Holes and Stainless Steel Breather Drains
• Cast-Iron Conduit Box is 90 Degree Rotatable, Oversized
• Non-Sparking Plastic Fan
• Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 6 Leads 150HP and Larger
• Number of Leads 575V: 3 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Interchangeable F1 and F2 mounting
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Brass Flinger on Both Ends
• *HPE™ High Pulse Endurance Spike Resistant Wire
• Phenolic Alkyd Resin Varnish
• Klixon 9700K Thermostats – 1 per phase
OTHER FEATURES
• CSA/UL Certified for Class I, Division 1, Group **C & D and Class I, Zone 1 Groups **IIB & IIA; and Class II, Division 1, Groups E, F & G;
Temp Code T3B
• *CSA Inverter Duty Speed Range Includes 5:1 CT / 20:1 VT for 140-180T Frames; 10:1 CT / 20:1 VT for 210-440T Frames
• *UL Inverter Duty Speed Range Includes 6:1 CT / 20:1 VT for 140-210T Frames; 4.6:1 CT / 20:1 VT for 250-320T Frames and 3.75:1 CT /
20:1VT for 360-440T Frames
• *Meets NEMA MG1 Part 31.4.4.2
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
** Up to 256T
A - 32
Motor Products - OPTIM® TEXP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEXP
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
CL I-GR C(5) AND D AND CL II-GR E, F & G
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHHXV, AEHHXU
Effective 04-10-14
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
XH0014
XH0016
AEHHXV
AEHHXV
1
1
1800
1200
230/460V
230/460V
143T
145T
1.61
1.72
85.5
82.5
62
70
465
519
XH1/52
XH1/54
XH1/56
AEHHXV
AEHHXV
AEHHXV
1.5
1.5
1.5
3600
1800
1200
230/460V
230/460V
230/460V
143T
145T
182T
1.99
2.15
2.55
84.0
86.5
87.5
62
70
108
511
511
587
XH0022
XH0024
XH0026
AEHHXV
AEHHXV
AEHHXV
2
2
2
3600
1800
1200
230/460V
230/460V
230/460V
145T
145T
184T
2.52
2.78
3.07
85.5
86.5
88.5
70
70
120
540
524
667
XH0032
XH0034
XH0036
AEHHXV
AEHHXV
AEHHXV
3
3
3
3600
1800
1200
230/460V
230/460V
230/460V
182T
182T
213T
3.57
3.87
3.92
87.5
89.5
89.5
108
108
187
603
612
889
XH0052
XH0054
XH0056
AEHHXV
AEHHXV
AEHHXV
5
5
5
3600
1800
1200
230/460V
230/460V
230/460V
184T
184T
215T
5.81
6.23
6.41
88.5
89.5
90.2
120
120
211
704
704
1,093
XH7/52
XH7/54
XH7/56
AEHHXV
AEHHXV
AEHHXV
7.5
7.5
7.5
3600
1800
1200
230/460V
230/460V
230/460V
213T
213T
254T
9.02
8.85
9.41
89.5
91.7
91.0
187
187
330
906
1,014
1,342
XH0102
XH0104
XH0106
AEHHXV
AEHHXV
AEHHXV
10
10
10
3600
1800
1200
230/460V
230/460V
230/460V
215T
215T
256T
11.9
11.7
12.6
90.2
91.7
91.0
211
211
376
1,069
1,182
1,646
XH0152
XH0154
XH0156
AEHHXV
AEHHXV
AEHHXU
15
15
15
3600
1800
1200
230/460V
230/460V
230/460V
254T
254T
284T
16.8
17.9
18.5
91.0
92.4
91.7
330
330
488
1,323
1,509
2,247
XH0202
XH0204
XH0206
AEHHXV
AEHHXV
AEHHXU
20
20
20
3600
1800
1200
230/460V
230/460V
230/460V
256T
256T
286T
22.4
23.6
24.3
91.0
93.0
91.7
376
376
530
1,756
1,807
2,670
XH0252
XH0254
XH0256
AEHHXU
AEHHXU
AEHHXU
25
25
25
3600
1800
1200
230/460V
230/460V
230/460V
284TS
284T
324T
27.7
29.4
30.3
91.7
93.6
93.0
466
488
708
2,267
2,293
3,219
XH0302
XH0304
XH0306
AEHHXU
AEHHXU
AEHHXU
30
30
30
3600
1800
1200
230/460V
230/460V
230/460V
286TS
286T
326T
33.0
35.1
36.4
92.4
93.6
93.0
502
530
781
2,619
2,665
3,893
XH0402
XH0404
XH0406
AEHHXU
AEHHXU
AEHHXU
40
40
40
3600
1800
1200
230/460V
230/460V
230/460V
324TS
324T
364T
44.3
46.6
46.3
93.0
94.1
94.1
691
708
946
3,524
3,546
4,963
XH0502
XH0504
XH0506
AEHHXU
AEHHXU
AEHHXU
50
50
50
3600
1800
1200
230/460V
230/460V
230/460V
326TS
326T
365T
55.0
57.9
59.6
93.6
94.5
94.1
766
781
1019
4,328
4,200
5,637
XH0602
XH0604
XH0606
AEHHXU
AEHHXU
AEHHXU
60
60
60
3600
1800
1200
230/460V
230/460V
230/460V
364TS
364T
404T
64.5
67.2
69.1
93.6
95.0
94.5
913
946
1287
5,394
5,468
6,927
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated (460V).
For 50Hz, please contact a TWMI representative.
For 900RPM, please contact a TWMI representative.
Group C/IIB applies to frames 256T and below.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
300HP motors must be de-rated to 250HP when used with VFD.
Motor Products - OPTIM® TEXP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 33
LIST PRICES
PREMIUM EFFICIENCY TEXP
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
CL I-GR C(5) AND D AND CL II-GR E, F & G
HPE™ Inverter Duty Wire
NOTE:
A - 34
TYPE: AEHHXU
Effective 04-10-14
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
XH0752
XH0754
XH0756
AEHHXU
AEHHXU
AEHHXU
75
75
75
3600
1800
1200
230/460V
230/460V
230/460V
365TS
365T
405T
80.7
83.6
85.9
93.6
95.4
94.5
975
1019
1408
7,033
6,554
8,126
XH1002
XH1004
XH1006R
AEHHXU
AEHHXU
AEHHXU
100
100
100
3600
1800
1200
230/460V
230/460V
230/460V
405TS
405T
444T
108
109
94
94.5
95.4
95.0
1349
1408
1650
9,156
8,126
10,679
XH1252
XH1254R
XH1256R
AEHHXU
AEHHXU
AEHHXU
125
125
125
3600
1800
1200
230/460V
230/460V
230/460V
444TS
444T
445T
114
110
118
95.0
95.4
95.0
1560
1600
1720
12,107
11,240
14,270
XH1502
XH1504R
XH1506R
AEHHXU
AEHHXU
AEHHXU
150
150
150
3600
1800
1200
460V
460V
460V
445TS
445T
447T
135
132
174
95.0
95.8
95.0
1600
1780
2170
14,048
13,658
19,872
XH2002
XH2004R
XH2006R
AEHHXU
AEHHXU
AEHHXU
200
200
200
3600
1800
1200
460V
460V
460V
447TS
447T
449T
221
224
230
94.5
95.4
95.0
1900
2220
2450
18,234
18,197
22,477
XH2502
XH2504R
AEHHXU
AEHHXU
250
250
3600
1800
460V
460V
449TS
449T
272
277
95.0
95.4
2320
2450
20,019
19,993
XH3002
XH3004R
AEHHXU
AEHHXU
300
300
3600
1800
460V
460V
449TS
449T
325
332
95.0
95.4
2550
2580
22,491
21,852
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated (460V).
For 50Hz, please contact a TWMI representative.
For 900RPM, please contact a TWMI representative.
Group C/IIB applies to frames 256T and below.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
300HP motors must be de-rated to 250HP when used with VFD.
Motor Products - OPTIM® TEXP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEXP
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
CL I-GR C(4) AND D AND CL II-GR E, F & G
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHHXV, AEHHXU
Effective 04-10-14
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
XH00145
XH00165
AEHHXV
AEHHXV
1
1
1800
1200
575V
575V
143T
145T
1.29
1.38
85.5
82.5
62
70
465
519
XH1/525
XH1/545
XH1/565
AEHHXV
AEHHXV
AEHHXV
1.5
1.5
1.5
3600
1800
1200
575V
575V
575V
143T
145T
182T
1.59
1.72
2.04
84.0
86.5
87.5
62
70
108
511
511
587
XH00225
XH00245
XH00265
AEHHXV
AEHHXV
AEHHXV
2
2
2
3600
1800
1200
575V
575V
575V
145T
145T
184T
2.01
2.22
2.45
85.5
86.5
88.5
70
70
120
540
524
667
XH00325
XH00345
XH00365
AEHHXV
AEHHXV
AEHHXV
3
3
3
3600
1800
1200
575V
575V
575V
182T
182T
213T
2.85
3.10
3.14
87.5
89.5
89.5
108
108
187
603
612
889
XH00525
XH00545
XH00565
AEHHXV
AEHHXV
AEHHXV
5
5
5
3600
1800
1200
575V
575V
575V
184T
184T
215T
4.65
4.98
5.13
88.5
89.5
90.2
120
120
211
704
704
1,093
XH7/525
XH7/545
XH7/565
AEHHXV
AEHHXV
AEHHXV
7.5
7.5
7.5
3600
1800
1200
575V
575V
575V
213T
213T
254T
7.22
7.08
7.53
89.5
91.7
91.0
187
187
330
906
1,014
1,342
XH01025
XH01045
XH01065
AEHHXV
AEHHXV
AEHHXV
10
10
10
3600
1800
1200
575V
575V
575V
215T
215T
256T
9.55
9.34
10.1
90.2
91.7
91.0
211
211
376
1,069
1,182
1,646
XH01525
XH01545
XH01565
AEHHXV
AEHHXV
AEHHXU
15
15
15
3600
1800
1200
575V
575V
575V
254T
254T
284T
13.4
14.3
14.8
91.0
92.4
91.7
330
330
488
1,323
1,509
2,247
XH02025
XH02045
XH02065
AEHHXV
AEHHXV
AEHHXU
20
20
20
3600
1800
1200
575V
575V
575V
256T
256T
286T
17.9
18.8
19.4
91.0
93.0
91.7
376
376
530
1,756
1,807
2,670
XH02525
XH02545
XH02565
AEHHXU
AEHHXU
AEHHXU
25
25
25
3600
1800
1200
575V
575V
575V
284TS
284T
324T
22.2
23.5
24.3
91.7
93.6
93.0
466
488
708
2,267
2,293
3,219
XH03025
XH03045
XH03065
AEHHXU
AEHHXU
AEHHXU
30
30
30
3600
1800
1200
575V
575V
575V
286TS
286T
326T
26.4
28.1
29.1
92.4
93.6
93.0
502
530
781
2,619
2,665
3,893
XH04025
XH04045
XH04065
AEHHXU
AEHHXU
AEHHXU
40
40
40
3600
1800
1200
575V
575V
575V
324TS
324T
364T
35.4
37.2
37.0
93.0
94.1
94.1
691
708
946
3,524
3,546
4,963
XH05025
XH05045
XH05065
AEHHXU
AEHHXU
AEHHXU
50
50
50
3600
1800
1200
575V
575V
575V
326TS
326T
365T
44.0
46.4
47.7
93.6
94.5
94.1
766
781
1019
4,328
4,200
5,637
XH06025
XH06045
XH06065
AEHHXU
AEHHXU
AEHHXU
60
60
60
3600
1800
1200
575V
575V
575V
364TS
364T
404T
51.6
53.8
55.3
93.6
95.0
94.5
913
946
1287
5,394
5,468
6,927
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Prices subject to change without notice.
For 50Hz, please contact a TWMI representative.
For 900RPM, please contact a TWMI representative.
Group C/IIB applies to frames 256T and below.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
300HP motors must be de-rated to 250HP when used with VFD.
Motor Products - OPTIM® TEXP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 35
LIST PRICES
PREMIUM EFFICIENCY TEXP
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
CL I-GR C(4) AND D AND CL II-GR E, F & G
HPE™ Inverter Duty Wire
NOTE:
A - 36
TYPE: AEHHXU
Effective 04-10-14
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
XH07525
XH07545
XH07565
AEHHXU
AEHHXU
AEHHXU
75
75
75
3600
1800
1200
575V
575V
575V
365TS
365T
405T
64.5
66.9
68.7
93.6
95.4
94.5
975
1019
1408
7,033
6,554
8,126
XH10025
XH10045
XH10065R
AEHHXU
AEHHXU
AEHHXU
100
100
100
3600
1800
1200
575V
575V
575V
405TS
405T
444T
86.2
87.2
75.5
94.5
95.4
95.0
1349
1408
1650
9,156
8,126
10,679
XH12525
XH12545R
XH12565R
AEHHXU
AEHHXU
AEHHXU
125
125
125
3600
1800
1200
575V
575V
575V
444TS
444T
445T
91
88
94
95.0
95.4
95.0
1560
1600
1720
12,107
11,240
14,270
XH15025
XH15045R
XH15065R
AEHHXU
AEHHXU
AEHHXU
150
150
150
3600
1800
1200
575V
575V
575V
445TS
445T
447T
108
106
139
95.0
95.8
95.0
1600
1780
2170
14,048
13,658
19,872
XH20025
XH20045R
XH20065R
AEHHXU
AEHHXU
AEHHXU
200
200
200
3600
1800
1200
575V
575V
575V
447TS
447T
449T
177
179
184
94.5
95.4
95.0
1900
2220
2450
18,234
18,197
22,477
XH25025
XH25045R
AEHHXU
AEHHXU
250
250
3600
1800
575V
575V
449TS
449T
218
222
95.0
95.4
2320
2450
20,019
19,993
XH30025
XH30045R
AEHHXU
AEHHXU
300
300
3600
1800
575V
575V
449TS
449T
260
266
95.0
95.4
2550
2580
22,491
21,852
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Prices subject to change without notice.
For 50Hz, please contact a TWMI representative.
For 900RPM, please contact a TWMI representative.
Group C/IIB applies to frames 256T and below.
For belt drive application, please contact a TWMI representative.
For VFD applcations please refer to page D-18.
300HP motors must be de-rated to 250HP when used with VFD.
Motor Products - OPTIM® TEXP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL: OPTIM® OILWELL
TYPE:
AEEAFP
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Any Applications Requiring NEMA Design D Torques
• Oil Well Pumps
PRODUCT OVERVIEW
• 3.5-100HP
• 1200 RPM
• 60Hz, 460V
• Totally Enclosed, IP54 Design
• Horizontal F2 Mount
DESIGN FEATURES
• 1.15 S.F.
• Class F Insulation
• Class B Temperature Rise
• Max Elevation 3300ft
• Continuous Duty
• NEMA Design D
• 40˚C Ambient
• Triple HP Ratings
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames
280TS, 320T and Larger
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame, Fan Cover and End Brackets
• Cast-Iron Conduit Box is 90 Degree Rotatable, Oversized and Gasketed
• Non-Sparking Plastic Fan
• Number of Leads 460V: 12 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and on Frame
• Interchangeable F1 and F2 mounting
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Rubber Flinger on DE up to 280T; Steel Flinger on Both Ends 320T and Larger
• Phenolic Alkyd Resin Varnish with Red Varnish Coating
• Klixon 9700K Thermostats – 1 per phase
OTHER FEATURES
• CSA Certified
Motor Products -OPTIM® OILWELL
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 37
LIST PRICES
OILWELL PUMP MOTOR
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design D, High Torque, High Slip
Class F Insulation, 40°C Ambient
TRIPLE RATE
NOTE:
A - 38
TYPE: AEEAFP
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
TR7.56
AEEAFP
3.5
5
7.5
1200
460V
254T
10.0
83.5
276
1,492
TR0106
AEEAFP
5
7.5
10
1200
460V
256T
13.3
84.0
314
1,751
TR0156
AEEAFP
7.5
10
15
1200
460V
284T
18.7
85.5
420
2,490
TR0206
AEEAFP
10
15
20
1200
460V
286T
24.5
86.5
468
2,748
TR0256
AEEAFP
15
20
25
1200
460V
324T
30.5
87.0
635
3,616
TR0306
AEEAFP
20
25
30
1200
460V
326T
35.5
87.5
705
4,012
TR0406
AEEAFP
25
30
40
1200
460V
365T
47.5
88.5
906
6,070
TR0506
AEEAFP
30
40
50
1200
460V
404T
57.0
89.5
1166
7,146
TR0606
AEEAFP
40
50
60
1200
460V
405T
68.2
90.0
1212
8,288
TR0606LR
AEEAFP
40
50
60
1200
460V
444T
73.4
89.0
1400
9,175
TR0756R
AEEAFP
50
60
75
1200
460V
445T
91.2
89.5
1550
10,999
TR1006R
AEEAFP
60
75
100
1200
460V
445T
121
90.0
1600
12,695
(1) Prices subject to change without notice.
(2) F.L. Amps & Efficiency values are for the larger HP per rating.
Motor Products - OPTIM® OILWELL
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL: MAX-HT
TYPE:
AEEAGD
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Crushers
• Impactors
• Chippers/ Shredders
• Ball Mills/ Rolling Mills
• Any High Torque Application
PRODUCT OVERVIEW
• 20-600HP
• 1800, 1200 & 900 RPM
• Horizontal F1 Mount
• 60Hz, 460V or 575V
• Totally Enclosed IP55 Design
• EPACT Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design C
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Roller Bearing on DE; Oversized Vacuum Degassed Open Bearings with Regreaseable Provisions on NDE
• Polyrex EM Grease
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame and End Brackets
• Fabricated Steel Conduit Box, Oversized and Gasketed
• Fabricated Steel Fan Cover
• Cast Iron Fan 5007& 5009; Aluminum Fan 5800 Frames and Larger
• Number of Leads 460V: 6 Leads
• Number of Leads 575V: 6 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and on Frame
• Paint System: Epoxy Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• High Strength AISI 4140 Shaft Material
• Radius Step-Down Shaft Shoulder
• Steel Flinger on Both Ends
• *HPE™ High Pulse Endurance Spike Resistant Wire
• 2 Dips Epoxy Resin Varnish and 1 Spray Enamel Coat
• Locknut and Washer on NDE for Vertical Shaft Down Applications
• Thermistors – 1 per Phase, Terminated in Auxiliary Box
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger
OTHER FEATURES
• CSA Certified
• *Meets NEMA MG1 Part 31.4.4.2
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
Motor Products - MAX-HT
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 39
LIST PRICES
TEFC CRUSHER DUTY
NEMA Standard 3-Phase Motors
60Hz, 460V
NEMA Design C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 40
TYPE: AEEAGD
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
HT2008R
AEEAGD
200
900
460V
5007C
250
93.6
3550
25,982
HT2504R
HT2506R
HT2508R
AEEAGD
AEEAGD
AEEAGD
250
250
250
1800
1200
900
460V
460V
460V
5007C
5007C
5009C
281
293
311
94.1
94.1
94.1
3550
3550
4100
19,187
21,149
30,291
HT3004R
HT3006R
HT3008R
AEEAGD
AEEAGD
AEEAGD
300
300
300
1800
1200
900
460V
460V
460V
5007C
5009C
5806C
334
351
268
94.1
94.1
94.1
3550
4100
4850
21,943
26,072
37,078
HT3504R
HT3506R
HT3508R
AEEAGD
AEEAGD
AEEAGD
350
350
350
1800
1200
900
460V
460V
460V
5009C
5806C
5808C
389
407
428
94.1
94.5
94.5
4100
4850
5750
24,128
29,950
41,489
HT4004R
HT4006R
HT4008R
AEEAGD
AEEAGD
AEEAGD
400
400
400
1800
1200
900
460V
460V
460V
5806C
5808C
5808C
443
464
486
94.5
94.5
94.5
4850
5750
5750
29,236
34,998
48,928
HT4504R
HT4506R
AEEAGD
AEEAGD
450
450
1800
1200
460V
460V
5808C
5808C
495
521
94.5
94.5
5750
5750
33,029
37,786
HT5004R
HT5006R
AEEAGD
AEEAGD
500
500
1800
1200
460V
460V
5808C
5808C
550
579
94.5
94.5
5750
5750
35,903
41,062
HT6004R
HT6006R
AEEAGD
AEEAGD
600
600
1800
1200
460V
460V
5808C
5810C
656
691
95.1
95.1
5800
6400
42,758
55,763
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - MAX-HT
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
TEFC CRUSHER DUTY
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEEAGD
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
HT20085R
AEEAGD
200
900
575V
5007C
200
93.6
3550
25,982
HT25045R
HT25065R
HT25085R
AEEAGD
AEEAGD
AEEAGD
250
250
250
1800
1200
900
575V
575V
575V
5007C
5007C
5009C
225
234
249
94.1
94.1
94.1
3550
3550
4100
19,187
21,149
30,291
HT30045R
HT30065R
HT30085R
AEEAGD
AEEAGD
AEEAGD
300
300
300
1800
1200
900
575V
575V
575V
5007C
5009C
5806C
267
281
214
94.1
94.1
94.1
3550
4100
4850
21,943
26,072
37,078
HT35045R
HT35065R
HT35085R
AEEAGD
AEEAGD
AEEAGD
350
350
350
1800
1200
900
575V
575V
575V
5009C
5806C
5808C
311
326
342
94.1
94.5
94.5
4100
4850
5750
24,128
29,950
41,489
HT40045R
HT40065R
HT40085R
AEEAGD
AEEAGD
AEEAGD
400
400
400
1800
1200
900
575V
575V
575V
5806C
5808C
5808C
354
371
389
94.5
94.5
94.5
4850
5750
5750
29,236
34,998
48,928
HT45045R
HT45065R
AEEAGD
AEEAGD
450
450
1800
1200
575V
575V
5808C
5808C
396
417
94.5
94.5
5750
5750
33,029
37,786
HT50045R
HT50065R
AEEAGD
AEEAGD
500
500
1800
1200
575V
575V
5808C
5808C
440
463
94.5
94.5
5750
5750
35,903
41,062
HT60045R
HT60065R
AEEAGD
AEEAGD
600
600
1800
1200
575V
575V
5808C
5810C
525
553
95.1
95.1
5800
6400
42,758
55,763
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - MAX-HT
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 41
FEATURES
MODEL: ROLLED STEEL ODP
TYPE:
ASGH
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Pumps
• HVAC Equipment
• Compressors
PRODUCT OVERVIEW
• 1/4-40HP
• Open Drip Proof IP22 Design
• 60Hz, 230V/460V (Usable on 208V), or 575V
• Horizontal F1 Mount
• 3600, 1800 & 1200 RPM
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings
• Multemp SRL Grease
• Dynamically Balanced Die-Cast Aluminum Rotor
• Rolled Steel Frame with Cast-Iron End Brackets
• Rolled Steel Conduit Box; 90 Degree Rotatable, Oversized and Gasketed
• Number of Leads 230/460V: 9 Leads 1/4-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Rubber Flinger on DE
• *HPE™ High Pulse Endurance Spike Resistant Wire
• 56 Frame Available 1/4-3HP
• Phenolic Alkyd Resin Varnish
OTHER FEATURES
• *Meets NEMA MG1 Part 31.4.4.2
• CSA Certified, UL recognized and CE marked
• *Inverter Duty Speed Range 10:1 CT and 20:1 VT
• CSA Energy Efficiency Verification (EEV)
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
A - 42
Motor Products - ROLLED STEEL ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY ODP
NEMA Standard 3-Phase Motors
60Hz, 230/460V (Usable on 208V)
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: ASGH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
RD0012
RD0014
RD0016
ASGH
ASGH
ASGH
1
1
1
3600
1800
1200
230/460V
230/460V
230/460V
143T
143T
145T
1.37
1.45
1.72
77.0
82.5
80.0
28
35
36
249
241
286
RD1/52
RD1/54
RD1/56
ASGH
ASGH
ASGH
1.5
1.5
1.5
3600
1800
1200
230/460V
230/460V
230/460V
143T
145T
182T
1.91
2.00
3.01
84.0
86.5
86.5
28
40
68
268
265
331
RD0022
RD0024
RD0026
ASGH
ASGH
ASGH
2
2
2
3600
1800
1200
230/460V
230/460V
230/460V
145T
145T
184T
2.46
2.61
3.75
85.5
86.5
85.5
35
44
68
296
286
402
RD0032
RD0034
RD0036
ASGH
ASGH
ASGH
3
3
3
3600
1800
1200
230/460V
230/460V
230/460V
145T
182T
213T
3.91
4.30
4.60
85.5
89.5
88.5
35
60
95
323
331
569
RD0052
RD0054
RD0056
ASGH
ASGH
ASGH
5
5
5
3600
1800
1200
230/460V
230/460V
230/460V
182T
184T
215T
6.08
6.79
7.17
87.5
89.5
89.5
67
77
123
396
402
681
RD7/52
RD7/54
RD7/56
ASGH
ASGH
ASGH
7.5
7.5
7.5
3600
1800
1200
230/460V
230/460V
230/460V
184T
213T
254T
8.82
9.53
10.1
88.5
91.0
90.2
77
115
197
484
569
901
RD0102
RD0104
RD0106
ASGH
ASGH
ASGH
10
10
10
3600
1800
1200
230/460V
230/460V
230/460V
213T
215T
256T
12.1
12.2
12.8
90.2
91.7
91.7
123
143
234
616
681
1,099
RD0152
RD0154
RD0156
ASGH
ASGH
ASGH
15
15
15
3600
1800
1200
230/460V
230/460V
230/460V
215T
254T
284T
17.7
18.2
19.1
91.0
93.0
91.7
152
213
305
810
901
1,421
RD0202
RD0204
RD0206
ASGH
ASGH
ASGH
20
20
20
3600
1800
1200
230/460V
230/460V
230/460V
254T
256T
286T
22.7
24.3
24.7
91.7
93.0
92.4
202
234
364
1,048
1,099
1,699
RD0252
RD0254
ASGH
ASGH
25
25
3600
1800
230/460V
230/460V
256T
284T
28.1
29.4
91.7
93.6
202
295
1,261
1,449
RD0302
RD0304
ASGH
ASGH
30
30
3600
1800
230/460V
230/460V
284TS
286T
33.8
34.7
92.4
94.1
273
346
1,554
1,658
RD0402
ASGH
40
3600
230/460V
286TS
44.8
92.4
322
1,917
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ROLLED STEEL ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 43
LIST PRICES
PREMIUM EFFICIENCY ODP
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 44
TYPE: ASGH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
RD00125
RD00145
RD00165
ASGH
ASGH
ASGH
1
1
1
3600
1800
1200
575V
575V
575V
143T
143T
145T
1.10
1.16
1.38
77.0
82.5
80.0
28
35
36
249
241
286
RD1/525
RD1/545
RD1/565
ASGH
ASGH
ASGH
1.5
1.5
1.5
3600
1800
1200
575V
575V
575V
143T
145T
182T
1.53
1.60
2.41
84.0
86.5
86.5
28
40
68
268
265
331
RD00225
RD00245
RD00265
ASGH
ASGH
ASGH
2
2
2
3600
1800
1200
575V
575V
575V
145T
145T
184T
1.97
2.09
3.00
85.5
86.5
85.5
35
44
68
296
286
402
RD00325
RD00345
RD00365
ASGH
ASGH
ASGH
3
3
3
3600
1800
1200
575V
575V
575V
145T
182T
213T
3.13
3.44
3.68
85.5
89.5
88.5
35
60
95
323
331
569
RD00525
RD00545
RD00565
ASGH
ASGH
ASGH
5
5
5
3600
1800
1200
575V
575V
575V
182T
184T
215T
4.86
5.43
5.73
87.5
89.5
89.5
67
77
123
396
402
681
RD7/525
RD7/545
RD7/565
ASGH
ASGH
ASGH
7.5
7.5
7.5
3600
1800
1200
575V
575V
575V
184T
213T
254T
7.05
7.62
8.09
88.5
91.0
90.2
77
115
197
484
569
901
RD01025
RD01045
RD01065
ASGH
ASGH
ASGH
10
10
10
3600
1800
1200
575V
575V
575V
213T
215T
256T
9.71
9.72
10.3
90.2
91.7
91.7
123
143
234
616
681
1,099
RD01525
RD01545
RD01565
ASGH
ASGH
ASGH
15
15
15
3600
1800
1200
575V
575V
575V
215T
254T
284T
14.2
14.6
15.3
91.0
93.0
91.7
152
213
305
810
901
1,421
RD02025
RD02045
RD02065
ASGH
ASGH
ASGH
20
20
20
3600
1800
1200
575V
575V
575V
254T
256T
286T
18.2
19.4
19.8
91.7
93.0
92.4
202
234
364
1,048
1,099
1,699
RD02525
RD02545
ASGH
ASGH
25
25
3600
1800
575V
575V
256T
284T
22.4
23.5
91.7
93.6
202
295
1,261
1,449
RD03025
RD03045
ASGH
ASGH
30
30
3600
1800
575V
575V
284TS
286T
27.0
27.8
92.4
94.1
273
346
1,554
1,658
RD04025
ASGH
40
3600
575V
286TS
35.8
92.4
322
1,917
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - ROLLED STEEL ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL: OPTIM® ODP
TYPE:
ASHH
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Compressors
• Pumps
PRODUCT OVERVIEW
• 1-500HP
• Open Drip Proof IP22 Design
• 60Hz, 230V/460V (Usable on 208V), 460V or 575V
• Horizontal F1 Mount
• 3600, 1800 & 1200 RPM
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions
Frames 280TS, 320T and Larger
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame and End Brackets
• Rolled Steel Conduit Box up to 400T Frames; Fabricated Steel Conduit Box 440T Frames and Larger, Gasketed, F1 Mounting
• Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 6 Leads 150 and Above
• Number of Leads 575V: 3 Leads up to 449T; 6 Leads 5000 Frames and Larger
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Interchangeable F1 and F2 mounting up to 449T
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Rubber Flinger on DE up to 280T; Steel Flinger on DE 280TS and Larger
• *HPE™ High Pulse Endurance Spike Resistant Wire
• Phenolic Alkyd Resin Varnish 140T to 400T Frames; 2 Dips Phenolic Alkyd Resin Varnish and 1 Spray Enamel Coat 440T Frames
and Larger
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger
OTHER FEATURES
• CSA Certified, UL Recognized and CE Marked
• UL Listed (UL 1004-5) for Fire Pump Applications (1-400HP)
• CSA Energy Efficiency Verification (EEV)
• *Meets NEMA MG1 Part 31.4.4.2
• *Inverter Duty Speed Range 10:1 CT and 20:1 VT up to 300HP; **3:1 CT and 20:1 VT 301-500HP
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
Motor Products - OPTIM® ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 45
LIST PRICES
NEMA PREMIUM EFFICIENCY OPEN DRIP PROOF
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 46
TYPE: ASHH
Effective 05-13-14
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
SDP0014
SDP0016
ASHH
ASHH
1
1
1800
1200
230/460V
230/460V
143T
145T
1.40
1.74
85.5
82.5
53
66
266
329
SDP1/52
SDP1/54
SDP1/56
ASHH
ASHH
ASHH
1.5
1.5
1.5
3600
1800
1200
230/460V
230/460V
230/460V
143T
145T
182T
2.06
2.02
2.55
85.5
86.5
87.5
53
66
95
266
278
358
SDP0022
SDP0024
SDP0026
ASHH
ASHH
ASHH
2
2
2
3600
1800
1200
230/460V
230/460V
230/460V
145T
145T
184T
2.59
2.72
3.01
85.5
86.5
87.5
66
66
106
301
288
435
SDP0032
SDP0034
SDP0036
ASHH
ASHH
ASHH
3
3
3
3600
1800
1200
230/460V
230/460V
230/460V
145T
182T
213T
3.69
3.88
4.12
87.5
89.5
88.5
66
95
159
322
334
545
SDP0052
SDP0054
SDP0056
ASHH
ASHH
ASHH
5
5
5
3600
1800
1200
230/460V
230/460V
230/460V
182T
184T
215T
5.90
6.19
6.62
87.5
89.5
89.5
95
106
185
395
418
692
SDP7/52
SDP7/54
SDP7/56
ASHH
ASHH
ASHH
7.5
7.5
7.5
3600
1800
1200
230/460V
230/460V
230/460V
184T
213T
254T
8.65
8.97
9.85
88.5
91.0
90.2
106
159
247
489
572
953
SDP0102
SDP0104
SDP0106
ASHH
ASHH
ASHH
10
10
10
3600
1800
1200
230/460V
230/460V
230/460V
213T
215T
256T
11.8
11.7
12.6
90.2
91.7
91.7
159
185
287
608
712
1,083
SDP0152
SDP0154
SDP0156
ASHH
ASHH
ASHH
15
15
15
3600
1800
1200
230/460V
230/460V
230/460V
215T
254T
284T
17.8
17.9
18.5
90.2
93.0
91.7
185
247
357
827
991
1,405
SDP0202
SDP0204
SDP0206
ASHH
ASHH
ASHH
20
20
20
3600
1800
1200
230/460V
230/460V
230/460V
254T
256T
286T
22.8
23.3
24.3
91.0
93.0
92.4
247
287
397
1,103
1,171
1,748
SDP0252
SDP0254
SDP0256
ASHH
ASHH
ASHH
25
25
25
3600
1800
1200
230/460V
230/460V
230/460V
256T
284T
324T
27.7
28.7
30.3
91.7
93.6
93.0
287
357
520
1,302
1,405
2,205
SDP0302
SDP0304
SDP0306
ASHH
ASHH
ASHH
30
30
30
3600
1800
1200
230/460V
230/460V
230/460V
284TS
286T
326T
33.6
34.3
35.9
92.4
94.1
93.6
370
397
595
1,650
1,656
2,468
SDP0402
SDP0404
SDP0406
ASHH
ASHH
ASHH
40
40
40
3600
1800
1200
230/460V
230/460V
230/460V
286TS
324T
364T
44.3
46.3
45.7
92.4
94.1
94.1
412
520
699
2,018
2,097
3,032
SDP0502
SDP0504
SDP0506
ASHH
ASHH
ASHH
50
50
50
3600
1800
1200
230/460V
230/460V
230/460V
324TS
326T
365T
58.5
58.3
57.8
93.0
94.5
94.1
518
595
772
2,534
2,367
3,532
SDP0602
SDP0604
SDP0606
ASHH
ASHH
ASHH
60
60
60
3600
1800
1200
230/460V
230/460V
230/460V
326TS
364T
404T
69.0
69.6
69.5
93.6
95.0
94.5
578
699
948
2,822
3,032
4,318
SDP0752
SDP0754
SDP0756
ASHH
ASHH
ASHH
75
75
75
3600
1800
1200
230/460V
230/460V
230/460V
364TS
365T
405T
82.5
86.0
86.0
94.1
95.0
94.5
666
772
1058
3,614
3,609
5,184
(1) Prices subject to change without notice.
(2) Ratings over 125HP are single voltage rated only (460V).
Motor Products - OPTIM® ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
NEMA PREMIUM EFFICIENCY OPEN DRIP PROOF
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: ASHH
Effective 05-13-14
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
SDP1002
SDP1004
SDP1006
ASHH
ASHH
ASHH
100
100
100
3600
1800
1200
230/460V
230/460V
230/460V
365TS
404T
444T
110
115
120
94.1
95.4
95.0
730
948
1170
4,767
4,566
8,911
SDP1252
SDP1254
SDP1256
ASHH
ASHH
ASHH
125
125
125
3600
1800
1200
230/460V
230/460V
230/460V
404TS
405T
445T
137
145
150
94.1
95.4
95.0
902
1058
1280
7,058
6,134
10,703
SDP1502
SDP1504
SDP1506
ASHH
ASHH
ASHH
150
150
150
3600
1800
1200
460V
460V
460V
405TS
444T
445T
164
170
178
94.5
95.8
95.4
981
1320
1370
8,409
9,102
11,512
SDP2002
SDP2004
SDP2006
ASHH
ASHH
ASHH
200
200
200
3600
1800
1200
460V
460V
460V
444TS
445T
447T
223
226
236
95.0
95.8
95.4
1150
1430
1810
10,945
10,993
14,205
SDP2502
SDP2504
SDP2506
ASHH
ASHH
ASHH
250
250
250
3600
1800
1200
460V
460V
460V
445TS
447T
449T
278
281
296
95.0
95.8
95.4
1280
1760
2160
12,949
13,675
18,015
SDP3002
SDP3004
SDP3006
ASHH
ASHH
ASHH
300
300
300
3600
1800
1200
460V
460V
460V
445TS
449T
449T
331
335
338
95.4
95.8
95.4
1320
1870
2615
16,666
17,181
21,834
SDP3502
SDP3504
SDP3506
ASHH
ASHH
ASHH
350
350
350
3600
1800
1200
460V
460V
460V
447TS
449T
5009B
382
391
404
95.4
95.8
95.4
1590
2310
3715
18,846
18,267
32,887
SDP4002
SDP4004
SDP4006
ASHH
ASHH
ASHH
400
400
400
3600
1800
1200
460V
460V
460V
449TS
449T
5009B
434
446
463
95.8
95.8
95.8
1760
2445
3835
21,277
22,125
36,911
SDP4502
SDP4504
SDP4506
ASHH
ASHH
ASHH
450
450
450
3600
1800
1200
460V
460V
460V
449TS
5009B
5009B
486
498
521
95.8
96.2
96.2
2125
3620
3960
23,069
32,040
38,119
SDP5002
SDP5004
SDP5006
ASHH
ASHH
ASHH
500
500
500
3600
1800
1200
460V
460V
460V
449TS
5009B
5009B
536
553
579
95.8
96.2
96.2
2225
3790
4075
24,332
34,329
39,200
(1) Prices subject to change without notice.
(2) Ratings over 125HP are single voltage rated only (460V).
Motor Products - OPTIM® ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 47
LIST PRICES
NEMA PREMIUM EFFICIENCY OPEN DRIP PROOF
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 48
TYPE: ASHH
Effective 05-13-14
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
SDP00145
SDP00165
ASHH
ASHH
1
1
1800
1200
575V
575V
143T
145T
1.12
1.39
85.5
82.5
53
66
266
329
SDP1/525
SDP1/545
SDP1/565
ASHH
ASHH
ASHH
1.5
1.5
1.5
3600
1800
1200
575V
575V
575V
143T
145T
182T
1.64
1.61
2.04
85.5
86.5
87.5
53
66
95
266
278
358
SDP00225
SDP00245
SDP00265
ASHH
ASHH
ASHH
2
2
2
3600
1800
1200
575V
575V
575V
145T
145T
184T
2.07
2.18
2.41
85.5
86.5
87.5
66
66
106
301
288
435
SDP00325
SDP00345
SDP00365
ASHH
ASHH
ASHH
3
3
3
3600
1800
1200
575V
575V
575V
145T
182T
213T
2.95
3.10
3.30
87.5
89.5
88.5
66
95
159
322
334
545
SDP00525
SDP00545
SDP00565
ASHH
ASHH
ASHH
5
5
5
3600
1800
1200
575V
575V
575V
182T
184T
215T
4.72
4.95
5.30
87.5
89.5
89.5
95
106
185
395
418
692
SDP7/525
SDP7/545
SDP7/565
ASHH
ASHH
ASHH
7.5
7.5
7.5
3600
1800
1200
575V
575V
575V
184T
213T
254T
6.92
7.18
7.88
88.5
91.0
90.2
106
159
247
489
572
953
SDP01025
SDP01045
SDP01065
ASHH
ASHH
ASHH
10
10
10
3600
1800
1200
575V
575V
575V
213T
215T
256T
9.44
9.39
10.1
90.2
91.7
91.7
159
185
287
608
712
1,083
SDP01525
SDP01545
SDP01565
ASHH
ASHH
ASHH
15
15
15
3600
1800
1200
575V
575V
575V
215T
254T
284T
14.2
14.3
14.8
90.2
93.0
91.7
185
247
357
827
991
1,405
SDP02025
SDP02045
SDP02065
ASHH
ASHH
ASHH
20
20
20
3600
1800
1200
575V
575V
575V
254T
256T
286T
18.2
18.6
19.4
91.0
93.0
92.4
247
287
397
1,103
1,171
1,748
SDP02525
SDP02545
SDP02565
ASHH
ASHH
ASHH
25
25
25
3600
1800
1200
575V
575V
575V
256T
284T
324T
22.2
23.0
24.3
91.7
93.6
93.0
287
357
520
1,302
1,405
2,205
SDP03025
SDP03045
SDP03065
ASHH
ASHH
ASHH
30
30
30
3600
1800
1200
575V
575V
575V
284TS
286T
326T
26.9
27.4
28.8
92.4
94.1
93.6
370
397
595
1,650
1,656
2,468
SDP04025
SDP04045
SDP04065
ASHH
ASHH
ASHH
40
40
40
3600
1800
1200
575V
575V
575V
286TS
324T
364T
35.4
37.0
36.6
92.4
94.1
94.1
412
520
699
2,018
2,097
3,032
SDP05025
SDP05045
SDP05065
ASHH
ASHH
ASHH
50
50
50
3600
1800
1200
575V
575V
575V
324TS
326T
365T
46.8
46.6
46.3
93.0
94.5
94.1
518
595
772
2,534
2,367
3,532
SDP06025
SDP06045
SDP06065
ASHH
ASHH
ASHH
60
60
60
3600
1800
1200
575V
575V
575V
326TS
364T
404T
55.2
55.7
55.6
93.6
95.0
94.5
578
699
948
2,822
3,032
4,318
SDP07525
SDP07545
SDP07565
ASHH
ASHH
ASHH
75
75
75
3600
1800
1200
575V
575V
575V
364TS
365T
405T
66.0
68.8
68.8
94.1
95.0
94.5
666
772
1058
3,614
3,609
5,184
(1) Prices subject to change without notice.
Motor Products - OPTIM® ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
NEMA PREMIUM EFFICIENCY OPEN DRIP PROOF
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: ASHH
Effective 05-13-14
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
SDP10025
SDP10045
SDP10065
ASHH
ASHH
ASHH
100
100
100
3600
1800
1200
575V
575V
575V
365TS
404T
444T
88.0
91.8
96.0
94.1
95.4
95.0
730
948
1170
4,767
4,566
8,911
SDP12525
SDP12545
SDP12565
ASHH
ASHH
ASHH
125
125
125
3600
1800
1200
575V
575V
575V
404TS
405T
445T
110
116
120
94.1
95.4
95.0
902
1058
1280
7,058
6,134
10,703
SDP15025
SDP15045
SDP15065
ASHH
ASHH
ASHH
150
150
150
3600
1800
1200
575V
575V
575V
405TS
444T
445T
131
136
142
94.5
95.8
95.4
981
1320
1370
8,409
9,102
11,512
SDP20025
SDP20045
SDP20065
ASHH
ASHH
ASHH
200
200
200
3600
1800
1200
575V
575V
575V
444TS
445T
447T
178
181
189
95.0
95.8
95.4
1150
1430
1810
10,945
10,993
14,205
SDP25025
SDP25045
SDP25065
ASHH
ASHH
ASHH
250
250
250
3600
1800
1200
575V
575V
575V
445TS
447T
449T
222
225
237
95.0
95.8
95.4
1280
1760
2160
12,949
13,675
18,015
SDP30025
SDP30045
SDP30065
ASHH
ASHH
ASHH
300
300
300
3600
1800
1200
575V
575V
575V
445TS
449T
449T
265
268
270
95.4
95.8
95.4
1320
1870
2615
16,666
17,181
21,834
SDP35025
SDP35045
SDP35065
ASHH
ASHH
ASHH
350
350
350
3600
1800
1200
575V
575V
575V
447TS
449T
5009B
306
313
323
95.4
95.8
95.4
1590
2310
3715
18,846
18,267
32,887
SDP40025
SDP40045
SDP40065
ASHH
ASHH
ASHH
400
400
400
3600
1800
1200
575V
575V
575V
449TS
449T
5009B
347
357
370
95.8
95.8
95.8
1760
2445
3835
21,277
22,125
36,911
SDP45025
SDP45045
SDP45065
ASHH
ASHH
ASHH
450
450
450
3600
1800
1200
575V
575V
575V
449TS
5009B
5009B
389
398
417
95.8
96.2
96.2
2125
3620
3960
23,069
32,040
38,119
SDP50025
SDP50045
SDP50065
ASHH
ASHH
ASHH
500
500
500
3600
1800
1200
575V
575V
575V
449TS
5009B
5009B
429
442
463
95.8
96.2
96.2
2225
3790
4075
24,332
34,329
39,200
(1) Prices subject to change without notice.
Motor Products - OPTIM® ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 49
FEATURES
MODEL: GLOBAL XPE
TYPE:
AEHG_TK, AEJH_TK
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Compressors
• Pumps
PRODUCT OVERVIEW
• 150-2000HP
• Totally Enclosed IP54 Design
• 60Hz, 2300V/4000V
• Horizontal F1 Mount
• 3600, 1800, 1200 & 900 RPM
• NEMA Premium Efficiency (250-500HP)
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Vacuum Degassed Open Bearings with Regreaseable Provisions
• Polyrex EM Grease
• Dynamically Balanced Copper/Copper Alloy Rotor Construction
• Cast-Iron Frame, and End Brackets
• Fabricated Steel Conduit Box, Gasketed, F1 Mounting
• Fabricated Steel Fan Cover
• Aluminum Fan
• Number of Leads: 6
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and on Frame
• Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat
• Stainless Steel Nameplate
• 1045 Carbon Steel Shaft Material
• Labyrinth Type Steel Flinger on Both Ends
• Mica Insulated Form Wound Windings With Complete VPI Treatment
• Bi-Directional Rotation Except 3600RPM Motors
• Winding RTD's, Space Heaters and Provisions for Bearing RTD's
OTHER FEATURES
• *CSA Certified for Class I, Division II, Groups B, C and D and Class I, Zone 2, Groups IIB+H2, IIB and IIA
• Suitable for Across the Line or Reduced Voltage Starting
• **Suitable for use on a VFD (Please Contact TWMI for Speed Ranges)
* Please contact your TWMI representative for availability of certified motors.
** Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
A - 50
Motor Products - GLOBAL XPE
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA 3-Phase Motors
60Hz, 2300/4000V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
NOTE:
Effective 02-11-16
Supercedes All Previous
TYPE: AEHG_TK, AEJH_TK
VOLTAGE: 2300/4000V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
4000V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
XPE1508
AEHG_TK
150
900
2300/4000V
5007B
20.8
93.6
3600
29,950
XPE2006
XPE2008
AEHG_TK
AEHG_TK
200
200
1200
900
2300/4000V
2300/4000V
5007B
5009B
25.4
27.5
95.0
94.1
3550
4150
28,883
34,593
XPE2502
XPE2504
XPE2506
XPE2508
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
250
250
250
250
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5007A
5007B
5009B
5009B
30.8
30.3
31.7
34.1
95.0
95.0
95.0
95.0
3200
3500
4100
4300
29,020
28,790
33,181
41,244
XPE3002
XPE3004
XPE3006
XPE3008
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
300
300
300
300
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5009A
5009B
5009B
5011B
36.0
36.2
37.9
40.6
95.4
95.4
95.0
95.0
3500
4000
4350
4750
35,174
32,205
38,962
48,183
XPE3502
XPE3504
XPE3506
XPE3508
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
350
350
350
350
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5009A
5009B
5011B
5808B
42.0
42.2
44.2
47.1
95.4
95.4
95.0
95.0
3800
4350
4750
5100
38,144
38,904
43,996
55,341
XPE4002
XPE4004
XPE4006
XPE4008
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
400
400
400
400
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5011A
5011B
5011B
5808B
47.7
48.2
50.5
53.8
95.4
95.4
95.0
95.0
4800
4450
4500
5300
41,813
42,505
47,969
63,231
XPE4502
XPE4504
XPE4506
XPE4508
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
450
450
450
450
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5011A
5011B
5808B
5810B
53.7
54.0
56.4
60.2
95.4
954.0
95.4
95.0
5050
4800
5300
5900
50,004
45,691
53,464
67,998
XPE5002
XPE5004
XPE5006
XPE5008
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
500
500
500
500
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5808A
5808B
5810B
6808B
59.7
59.7
62.5
63.8
95.4
95.8
95.4
95.4
4700
5000
5300
7400
54,446
50,539
59,706
77,667
XPE6002
XPE6004
XPE6006
XPE6008
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
600
600
600
600
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5810A
5810B
5810B
6808B
71.3
71.9
74.9
76.9
95.8
95.8
95.4
95.4
5950
5600
5800
7900
58,392
63,258
70,705
87,533
XPE7002
XPE7004
XPE7006
XPE7008
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
700
700
700
700
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
5810A
5810B
6808B
6808B
82.9
83.6
86.8
88.5
96.2
95.8
95.8
95.4
6600
5750
7550
8650
60,775
71,438
79,012
89,991
XPE8002
XPE8004
XPE8006
XPE8008
XPEJ8008
AEHG_TK
AEHG_TK
AEHG_TK
AEHG_TK
AEJH_TK
800
800
800
800
800
3600
1800
1200
900
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
2300/4000V
6808A
6808B
6808B
6810B
450C
94.0
95.5
99.1
101
99.5
96.2
95.8
95.8
95.8
95.8
8350
7700
8400
11000
8600
84,438
77,058
83,226
93,384
93,384
(1) Prices subject to change without notice.
(2) For other voltages please contact a TWMI representative.
(3) Contact TWMI for special design criteria, VFD duty & Hazloc Ratings.
Motor Products - GLOBAL XPE
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 51
LIST PRICES
PREMIUM EFFICIENCY TEFC SEVERE DUTY
NEMA 3-Phase Motors
60Hz, 2300/4000V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
Effective 02-11-16
Supercedes All Previous
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
4000V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
XPEF9002
XPE9004
XPE9006
XPEJ9006
XPEJ9008
AFJH_S2
AEHG_TK
AEHG_TK
AEJH_TK
AEJH_TK
900
900
900
900
900
3600
1800
1200
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
2300/4000V
450C
6808B
6810B
450C
500C
*
108
112
111
111
*
95.8
95.8
95.8
95.8
*
8500
10560
8600
11900
106,317
81,399
85,983
85,983
103,437
XPEF10002
XPEJ10004
XPEJ10006
XPEJ10008
AFJH_S2
AEJH_TK
AEJH_TK
AEJH_TK
1000
1000
1000
1000
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
450C
450C
500C
500C
*
119
121
123
*
96.2
96.2
95.8
*
8600
11900
11900
122,943
85,211
93,429
112,356
XPEF12502
XPEJ12504
XPEJ12506
XPEJ12508
AFJH_S2
AEJH_TK
AEJH_TK
AEJH_TK
1250
1250
1250
1250
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
500C
500C
500C
560C
*
149
150
160
*
96.2
96.2
96.0
*
12600
11900
16100
149,507
90,538
110,577
120,487
XPEF15002
XPEJ15004
XPEJ15006
XPEJ15008
AFJH_S2
AEJH_TK
AEJH_TK
AEJH_TK
1500
1500
1500
1500
3600
1800
1200
900
2300/4000V
2300/4000V
2300/4000V
2300/4000V
560C
500C
560C
560C
*
179
188
192
*
96.5
96.2
96.0
*
12600
17000
18100
174,992
103,634
119,498
124,688
XPEF17502
XPEJ17504
XPEJ17506
AFJH_S2
AEJH_TK
AEJH_TK
1750
1750
1750
3600
1800
1200
2300/4000V
2300/4000V
2300/4000V
560C
560C
560C
*
207
219
*
96.5
96.2
*
16100
18100
198,902
116,631
125,923
XPEJ20004
AEJH_TK
2000
1800
2300/4000V
560C
229
96.5
17000
124,293
* Please contact your local TWMI sales representative for more information.
NOTE:
A - 52
TYPE: AEHG_TK, AEJH_TK
VOLTAGE: 2300/4000V
(1) Prices subject to change without notice.
(2) For other voltages please contact a TWMI representative.
(3) Contact TWMI for special design criteria, VFD duty & Hazloc Ratings.
Motor Products - GLOBAL XPE
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL: GLOBAL SERIES MEDIUM VOLTAGE ODP
TYPE:
ASHAPA
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Compressors
• Pumps
PRODUCT OVERVIEW
• 100-1750HP
• Open Drip Proof/WPI IP22/IPW22 Design
• 60Hz, 2300V/4160V
• Horizontal F1 Mount
• 3600, 1800, 1200 & 900 RPM
DESIGN FEATURES
• 1.15 S.F.
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Vacuum Degassed Open Bearings with Regreaseable Provisions
• Polyrex EM Grease
• Dynamically Balanced Die-Cast Aluminum Rotor up to 5011 Frames; Copper/Copper Alloy 5800 and Larger
• Cast-Iron Frame, and End Brackets
• Cast-Iron Conduit Box is 90 Degree Rotatable, Oversized and Gasketed
• Number of Leads: 3 or 6
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box and on Frame
• Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat
• Stainless Steel Nameplate
• 1045 Carbon Steel Shaft Material
• Labyrinth Type Steel Flinger on Both Ends
• Mica Insulated Formed Coil with Class F Thermalastic Epoxy Insulation
• Bi-Directional Rotation, Except 2 Pole Motors 5000 Frames and Larger
• 100OHM Platinum Winding RTD’s, 2 per Phase, Terminated in Separate Auxiliary Box
• 120V Space Heaters, Terminated in Separate Auxiliary Box
OTHER FEATURES
• CSA Certified
• Suitable for Across the Line or Reduced Voltage Starting
Motor Products - GLOBAL ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 53
LIST PRICES
HIGH EFFICIENCY ODP SEVERE DUTY
NEMA 3-Phase Motors
60Hz, 2300/4160V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
NOTE:
A - 54
Effective 02-11-16
Supercedes All Previous
TYPE: ASHAPA
VOLTAGE: 2300/4160V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
4160V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
GDP1002
GDP1004
GDP1006
GDP1008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
100
100
100
100
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
444TS
444T
445T
447T
12.6
13.0
14.2
14.8
91.0
91.0
91.0
91.0
1230
1245
1370
1850
11,339
11,590
15,803
18,621
GDP1252
GDP1254
GDP1256
GDP1258
ASHAPA
ASHAPA
ASHAPA
ASHAPA
125
125
125
125
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
444TS
444T
447T
449T
15.8
16.3
17.7
18.2
91.0
91.0
91.7
91.0
1300
1325
1850
2150
13,123
13,096
18,355
21,179
GDP1502
GDP1504
GDP1506
GDP1508
ASHAPA
ASHAPA
ASHAPA
ASHAPA
150
150
150
150
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
445TS
445T
449T
5007B
18.8
19.4
21.0
22.1
91.7
91.7
91.7
91.0
1360
1390
2200
3300
14,851
15,112
20,741
25,277
GDP2002
GDP2004
GDP2006
GDP2008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
200
200
200
200
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
447TS
447T
5007B
5009B
24.9
26.0
27.7
28.8
91.7
91.7
91.7
91.7
1650
1840
3300
3750
17,501
17,276
24,167
28,551
GDP2502
GDP2504
GDP2506
GDP2508
ASHAPA
ASHAPA
ASHAPA
ASHAPA
250
250
250
250
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
449TS
449T
5007B
5009B
31.0
32.1
33.3
35.7
92.4
92.4
92.4
92.4
2000
2200
3300
3750
19,807
19,737
27,302
31,859
GDP3002
GDP3004
GDP3006
GDP3008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
300
300
300
300
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
449TS
5007B
5009B
5808B
36.5
37.8
39.8
41.7
93.0
93.0
93.0
93.0
2200
3300
3750
5100
22,988
24,118
30,314
34,742
GDP3502
GDP3504
GDP3506
GDP3508
ASHAPA
ASHAPA
ASHAPA
ASHAPA
350
350
350
350
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5007A
5007B
5009B
5808B
43.2
43.7
46.4
48.7
93.0
93.6
93.0
93.0
2950
3300
3750
5100
27,712
26,528
32,218
38,089
GDP4002
GDP4004
GDP4006
GDP4008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
400
400
400
400
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5009A
5009B
5808B
5808B
48.9
49.4
51.8
54.6
93.6
93.6
93.6
93.0
3050
3750
5100
5100
30,015
28,927
34,064
41,439
GDP4502
GDP4504
GDP4506
GDP4508
ASHAPA
ASHAPA
ASHAPA
ASHAPA
450
450
450
450
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5808A
5808B
5808B
5810B
54.7
56.4
58.1
60.8
93.6
93.6
93.6
93.0
4900
5100
5100
6300
32,710
31,867
36,860
44,795
GDP5002
GDP5004
GDP5006
GDP5008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
500
500
500
500
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5808A
5808B
5808B
5810B
60.3
61.4
64.1
66.9
94.1
94.1
94.1
93.6
4900
5100
5100
6300
35,524
33,052
39,666
47,928
(1) Prices subject to change without notice.
(2) For other voltages please contact a TWMI representative.
(3) Not stocked in Canada. Please contact your TWMI representative for delivery.
Motor Products - GLOBAL ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
HIGH EFFICIENCY ODP SEVERE DUTY
NEMA 3-Phase Motors
60Hz, 2300/4160V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
Effective 02-11-16
Supercedes All Previous
TYPE: ASHAPA
VOLTAGE: 2300/4160V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
4160V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
GDP6002
GDP6004
GDP6006
GDP6008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
600
600
600
600
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5808A
5808B
5810B
6806B
71.9
73.5
76.3
78.5
94.5
94.1
94.1
94.1
4900
5100
6300
7400
37,852
36,960
43,680
54,669
GDP7002
GDP7004
GDP7006
GDP7008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
700
700
700
700
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5810A
5808B
5810B
6808B
83.5
85.1
88.5
91.2
94.5
94.5
94.5
94.5
5100
5100
6300
8400
42,251
39,972
47,478
60,489
GDP8002
GDP8004
GDP8006
GDP8008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
800
800
800
800
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5810A
5810B
6806B
6808B
95.1
97.3
101
104
95.0
94.5
94.5
94.5
5100
6300
7400
8400
44,377
43,244
51,975
67,072
GDP9002
GDP9004
GDP9006
GDP9008
ASHAPA
ASHAPA
ASHAPA
ASHAPA
900
900
900
900
3600
1800
1200
900
2300/4160V
2300/4160V
2300/4160V
2300/4160V
5810A
5810B
6806B
6808B
107
109
113
*
95.0
95.0
95.0
*
*
6300
7400
8400
48,003
45,613
57,427
73,416
GDP10002
GDP10004
GDP10006
ASHAPA
ASHAPA
ASHAPA
1000
1000
1000
3600
1800
1200
2300/4160V
2300/4160V
2300/4160V
5810A
6806B
6808B
*
121
126
*
95.0
95.0
*
7400
8400
56,820
50,720
61,721
GDP12504
GDP12506
ASHAPA
ASHAPA
1250
1250
1800
1200
2300/4160V
2300/4160V
6808B
6808B
151
*
95.0
*
8400
8400
60,847
72,561
GDP15004
GDP15006
ASHAPA
ASHAPA
1500
1500
1800
1200
2300/4160V
2300/4160V
6808B
6808B
*
*
*
*
8400
8400
66,086
78,791
GDP17504
ASHAPA
1750
1800
2300/4160V
6808B
*
*
8400
69,526
* Please contact your local TWMI sales representative for more information.
NOTE:
(1) Prices subject to change without notice.
(2) For other voltages please contact a TWMI representative.
(3) Not stocked in Canada. Please contact your TWMI representative for delivery.
Motor Products - GLOBAL ODP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 55
FEATURES
MODEL: FARM DUTY
TYPE:
BEGCFD, BECCFD, BECSFD
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Fans & Blowers
• Pumps
• Compressors
• Farm Equipment
• Machine Tools
PRODUCT OVERVIEW
• 1/3-10 HP
• Totally Enclosed IP44 Design
• 60Hz, 115/230V OR 230V; Single Phase
• Horizontal F1 Mount
• 1800RPM
DESIGN FEATURES
• 1.15 S.F.
• 40˚C Ambient
• Continuous Duty
• Max Elevation 3300ft
• High Torque
• Class B Insulation up to 3HP; Class F Insulation 3-10HP
• Class B Temperature Rise
• Capacitor Start, Induction Run .33-1.5HP; Capacitor Start, Capacitor Run 2-10HP
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings
• Multemp SRL Grease
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame and End Brackets 1.5-10HP, Rolled Steel for Others
• Rolled Steel Fan Cover and Terminal Box
• Plastic Fan
• Grounding Terminal Inside Main Terminal Box
• Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat
• Rubber Flinger on DE
• Phenolic Alkyd Resin Varnish
• Manual Reset Overload
OTHER FEATURES
• CSA approved, UL Recognized
A - 56
Motor Products - FARM DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
HIGH EFFICIENCY TEFC
NEMA Standard Single Phase Motors, 60Hz
High Torque, Continuous Duty
40°C Ambient, 1.15 S.F.
Manual Reset Overload Protector
NOTE:
Effective 02-11-16
Supercedes All Previous
TYPE: BEGCFD, BECCFD, BECSFD
VOLTAGE: 115/230V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
230V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
FD0/34
BEGCFD
0.33
1800
115/230V
56
4.25
51.0
14.5
200
FD0/54
BEGCFD
0.50
1800
115/230V
56
4.7
58.0
16
210
FD0/74
BEGCFD
0.75
1800
115/230V
56
6.1
65.0
17
219
FD0014
BEGCFD
1
1800
115/230V
56
7.0
70.0
48
234
FD1/54
BECCFD
1.5
1800
115/230V
145T
11.0
70.0
70
321
FD0024
BECCFD
2
1800
115/230V
182T
14.0
73.0
92
442
FD0034
BECSFD
3
1800
230V
182T
21.0
74.0
92
521
FD0054
BECSFD
5
1800
230V
184T
30.0
78.5
103
595
FD7/54
BECSFD
7.5
1800
230V
213T
36.0
80.0
178
986
FD0104
BECSFD
10
1800
230V
215T
48.0
78.5
181
1,134
(1) Prices subject to change without notice.
(2) 115/230V :1/3-2HP; 230V :3-10HP.
Motor Products - FARM DUTY
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 57
FEATURES
MODEL: OPTIM® JP
TYPE:
AEHH8N-JP
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Pumps
PRODUCT OVERVIEW
• 1-75HP
• Totally Enclosed IP54 Design
• 60Hz, 230V/460V (Usable on 208V), or 575V
• Horizontal F1 Mount
• 3600, 1800 & 1200 RPM
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class B Temperature Rise
• Continuous Duty
• 40˚C Ambient
• Class F Insulation
• Max Elevation 3300ft
• NEMA Design B or C
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 140JP(2,4&6Pole)-280JP(4&6Pole) and Open Bearings with
Regreaseable Provisions Frames 280JP(2Pole), 320JP(2,4&6Pole) and Larger
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame and End Brackets
• Cast-Iron Fan Cover and Terminal Box
• Non-Sparking Plastic Fan
• Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Interchangeable F1 and F2 mounting
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Rubber Flinger on DE Frames 140JP(2,4&6Pole)-280JP(4&6Pole); Steel Flinger on Both Ends 280JP(2Pole), 320JP(2,4&6Pole) and Larger
• Phenolic Alkyd Resin Varnish
• *HPE™ High Pulse Endurance Spike Resistant Wire
• JP Pump Shaft
OTHER FEATURES
• CSA Certified for Class I, Division II, Groups B, C and D and Class I, Zone 2, Groups IIB+H2, IIB and IIA
• *Inverter Duty Speed Range 10:1 CT and 20:1 VT
• *Meets NEMA MG1 Part 31.4.4.2
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
A - 58
Motor Products - OPTIM® JP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC PUMP MOTOR
NEMA Standard 3-Phase Motors
60Hz, 230/460V (Usable on 208V)
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8N-JP
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
CJP0012
CJP0014
CJP0016
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
1
1
1
3600
1800
1200
230/460V
230/460V
230/460V
143JP
143JP
145JP
1.34
1.50
1.73
82.5
85.5
82.5
46
61
68
381
381
473
CJP1/52
CJP1/54
CJP1/56
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
1.5
1.5
1.5
3600
1800
1200
230/460V
230/460V
230/460V
143JP
145JP
182JP
2.00
2.08
2.53
84.0
86.5
87.5
61
68
106
432
431
517
CJP0022
CJP0024
CJP0026
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
2
2
2
3600
1800
1200
230/460V
230/460V
230/460V
145JP
145JP
184JP
2.52
2.78
3.00
86.5
86.5
88.5
68
68
126
465
461
583
CJP0032
CJP0034
CJP0036
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
3
3
3
3600
1800
1200
230/460V
230/460V
230/460V
182JP
182JP
213JP
3.53
3.74
4.02
88.5
89.5
89.5
106
106
186
524
520
818
CJP0052
CJP0054
CJP0056
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
5
5
5
3600
1800
1200
230/460V
230/460V
230/460V
184JP
184JP
215JP
5.72
6.12
6.24
88.5
89.5
91.0
126
126
213
623
586
1,008
CJP7/52
CJP7/54
CJP7/56
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
7.5
7.5
7.5
3600
1800
1200
230/460V
230/460V
230/460V
213JP
213JP
254JP
8.67
8.85
9.59
91.0
91.7
91.0
186
186
325
832
850
1,415
CJP0102
CJP0104
CJP0106
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
10
10
10
3600
1800
1200
230/460V
230/460V
230/460V
215JP
215JP
256JP
11.5
11.6
12.8
91.0
91.7
91.0
213
213
354
997
1,034
1,734
CJP0152
CJP0154
CJP0156
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
15
15
15
3600
1800
1200
230/460V
230/460V
230/460V
254JP
254JP
284JP
16.6
17.3
18.2
92.4
92.4
92.4
325
325
464
1,364
1,338
2,258
CJP0202
CJP0204
CJP0206
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
20
20
20
3600
1800
1200
230/460V
230/460V
230/460V
256JP
256JP
286JP
21.9
23.0
24.3
92.4
93.0
91.7
354
354
507
1,745
1,737
2,826
CJP0252
CJP0254
CJP0256
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
25
25
25
3600
1800
1200
230/460V
230/460V
230/460V
284JP
284JP
324JP
27.8
29.1
30.3
92.4
93.6
93.0
464
464
694
2,199
2,174
3,380
CJP0302
CJP0304
CJP0306
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
30
30
30
3600
1800
1200
230/460V
230/460V
230/460V
286JP
286JP
326JP
33.2
34.3
37.5
93.0
93.6
93.0
507
507
784
2,559
2,559
4,113
CJP0402
CJP0404
CJP0406
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
40
40
40
3600
1800
1200
230/460V
230/460V
230/460V
324JP
324JP
364JP
44.2
46.3
46.0
94.1
94.1
94.1
694
694
926
3,317
3,295
5,282
CJP0502
CJP0504
CJP0506
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
50
50
50
3600
1800
1200
230/460V
230/460V
230/460V
326JP
326JP
365JP
54.7
56.9
57.8
94.1
94.5
94.1
784
784
954
4,215
4,157
6,525
CJP0602
CJP0604
AEHH8N-JP
AEHH8N-JP
60
60
3600
1800
230/460V
230/460V
364JP
364JP
64.2
68.4
94.1
95.0
926
926
5,432
5,212
CJP0752
CJP0754
AEHH8N-JP
AEHH8N-JP
75
75
3600
1800
230/460V
230/460V
365JP
365JP
79.9
85.1
94.5
95.4
954
954
6,807
6,612
(1) Prices subject to change without notice.
(2) Not stocked in Canada. Please contact your TWMI representative for delivery.
(3) For VFD applcations please refer to page D-18.
Motor Products - OPTIM® JP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 59
LIST PRICES
PREMIUM EFFICIENCY TEFC PUMP MOTOR
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 60
TYPE: AEHH8N-JP
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
CJP00125
CJP00145
CJP00165
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
1
1
1
3600
1800
1200
575V
575V
575V
143JP
143JP
145JP
1.07
1.20
1.38
82.5
85.5
82.5
46
61
68
381
381
473
CJP1/525
CJP1/545
CJP1/565
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
1.5
1.5
1.5
3600
1800
1200
575V
575V
575V
143JP
145JP
182JP
1.60
1.66
2.02
84.0
86.5
87.5
61
68
106
432
431
517
CJP00225
CJP00245
CJP00265
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
2
2
2
3600
1800
1200
575V
575V
575V
145JP
145JP
184JP
2.02
2.22
2.40
86.5
86.5
88.5
68
68
126
465
461
583
CJP00325
CJP00345
CJP00365
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
3
3
3
3600
1800
1200
575V
575V
575V
182JP
182JP
213JP
2.82
2.99
3.22
88.5
89.5
89.5
106
106
186
524
520
818
CJP00525
CJP00545
CJP00565
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
5
5
5
3600
1800
1200
575V
575V
575V
184JP
184JP
215JP
4.58
4.90
4.99
88.5
89.5
91.0
126
126
213
623
586
1,008
CJP7/525
CJP7/545
CJP7/565
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
7.5
7.5
7.5
3600
1800
1200
575V
575V
575V
213JP
213JP
254JP
6.94
7.08
7.67
91.0
91.7
91.0
186
186
325
832
850
1,415
CJP01025
CJP01045
CJP01065
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
10
10
10
3600
1800
1200
575V
575V
575V
215JP
215JP
256JP
9.20
9.28
10.2
91.0
91.7
91.0
213
213
354
997
1,034
1,734
CJP01525
CJP01545
CJP01565
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
15
15
15
3600
1800
1200
575V
575V
575V
254JP
254JP
284JP
13.3
13.8
14.6
92.4
92.4
92.4
325
325
464
1,364
1,338
2,258
CJP02025
CJP02045
CJP02065
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
20
20
20
3600
1800
1200
575V
575V
575V
256JP
256JP
286JP
17.5
18.4
19.4
92.4
93.0
91.7
354
354
507
1,745
1,737
2,826
CJP02525
CJP02545
CJP02565
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
25
25
25
3600
1800
1200
575V
575V
575V
284JP
284JP
324JP
22.2
23.3
24.2
92.4
93.6
93.0
464
464
694
2,199
2,174
3,380
CJP03025
CJP03045
CJP03065
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
30
30
30
3600
1800
1200
575V
575V
575V
286JP
286JP
326JP
26.6
27.4
30.0
93.0
93.6
93.0
507
507
784
2,559
2,559
4,113
CJP04025
CJP04045
CJP04065
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
40
40
40
3600
1800
1200
575V
575V
575V
324JP
324JP
364JP
35.4
37.0
36.8
94.1
94.1
94.1
694
694
926
3,317
3,295
5,282
CJP05025
CJP05045
CJP05065
AEHH8N-JP
AEHH8N-JP
AEHH8N-JP
50
50
50
3600
1800
1200
575V
575V
575V
326JP
326JP
365JP
43.8
45.5
46.2
94.1
94.5
94.1
784
784
954
4,215
4,157
6,525
CJP06025
CJP06045
AEHH8N-JP
AEHH8N-JP
60
60
3600
1800
575V
575V
364JP
364JP
51.4
54.7
94.1
95.0
926
926
5,432
5,212
CJP07525
CJP07545
AEHH8N-JP
AEHH8N-JP
75
75
3600
1800
575V
575V
365JP
365JP
63.9
68.1
94.5
95.4
954
954
6,807
6,612
(1) Prices subject to change without notice.
(2) Not stocked in Canada. Please contact your TWMI representative for delivery.
(3) For VFD applcations please refer to page D-18.
Motor Products - OPTIM® JP
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL: OPTIM® JM
TYPE:
AEHH8N-JM
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Pumps
PRODUCT OVERVIEW
• 1-50HP
• Totally Enclosed IP54 Design
• 60Hz, 230V/460V (Usable on 208V), or 575V
• Horizontal F1 Mount
• 3600, 1800 & 1200 RPM
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class B Temperature Rise
• Continuous Duty
• 40˚C Ambient
• Class F Insulation
• Max Elevation 3300ft
• NEMA Design B or C
MECHANICAL FEATURES
• Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 140JM(2,4&6Pole)-280JM(4&6Pole) and Open Bearings with
Regreaseable Provisions Frames 280JM(2Pole), 320JM
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast-Iron Frame and End Brackets
• Cast-Iron Fan Cover and Terminal Box
• Non-Sparking Plastic Fan
• Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Interchangeable F1 and F2 mounting
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat
• Stainless Steel Nameplate
• Rubber Flinger on DE Frames 140JM(2,4&6Pole)-280JM(4&6Pole); Steel Flinger on Both Ends 280JM(2Pole), 320JM
• Phenolic Alkyd Resin Varnish
• *HPE™ High Pulse Endurance Spike Resistant Wire
• JM Pump Shaft
OTHER FEATURES
• CSA Certified for Class I, Division II, Groups B, C and D and Class I, Zone 2, Groups IIB+H2, IIB and IIA
• *Inverter Duty Speed Range 10:1 CT and 20:1 VT
• *Meets NEMA MG1 Part 31.4.4.2
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
Motor Products - OPTIM® JM
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 61
LIST PRICES
PREMIUM EFFICIENCY TEFC PUMP MOTOR
NEMA Standard 3-Phase Motors
60Hz, 230/460V (Usable on 208V)
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
A - 62
TYPE: AEHH8N-JM
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
CJM0012
CJM0014
CJM0016
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
1
1
1
3600
1800
1200
230/460V
230/460V
230/460V
143JM
143JM
145JM
1.34
1.50
1.73
82.5
85.5
82.5
61
61
68
381
381
473
CJM1/52
CJM1/54
CJM1/56
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
1.5
1.5
1.5
3600
1800
1200
230/460V
230/460V
230/460V
143JM
145JM
182JM
2.00
2.08
2.53
84.0
86.5
87.5
61
68
106
432
431
517
CJM0022
CJM0024
CJM0026
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
2
2
2
3600
1800
1200
230/460V
230/460V
230/460V
145JM
145JM
184JM
2.52
2.78
3.00
86.5
86.5
88.5
68
68
126
465
461
583
CJM0032
CJM0034
CJM0036
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
3
3
3
3600
1800
1200
230/460V
230/460V
230/460V
182JM
182JM
213JM
3.53
3.74
4.02
88.5
89.5
89.5
106
106
186
524
520
818
CJM0052
CJM0054
CJM0056
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
5
5
5
3600
1800
1200
230/460V
230/460V
230/460V
184JM
184JM
215JM
5.72
6.12
6.24
88.5
89.5
91.0
126
126
213
623
586
1,008
CJM7/52
CJM7/54
CJM7/56
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
7.5
7.5
7.5
3600
1800
1200
230/460V
230/460V
230/460V
213JM
213JM
254JM
8.67
8.85
9.59
91.0
91.7
91.0
186
186
325
832
850
1,415
CJM0102
CJM0104
CJM0106
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
10
10
10
3600
1800
1200
230/460V
230/460V
230/460V
215JM
215JM
256JM
11.50
11.60
12.80
91.0
91.7
91.0
213
213
354
997
1,034
1,734
CJM0152
CJM0154
CJM0156
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
15
15
15
3600
1800
1200
230/460V
230/460V
230/460V
254JM
254JM
284JM
16.60
17.30
18.20
92.4
92.4
92.4
325
325
464
1,364
1,338
2,258
CJM0202
CJM0204
CJM0206
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
20
20
20
3600
1800
1200
230/460V
230/460V
230/460V
256JM
256JM
286JM
21.90
23.00
24.30
92.4
93.0
91.7
354
354
507
1,745
1,737
2,826
CJM0252
CJM0254
CJM0256
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
25
25
25
3600
1800
1200
230/460V
230/460V
230/460V
284JM
284JM
324JM
27.80
29.10
30.30
92.4
93.6
93.0
464
464
694
2,199
2,174
3,380
CJM0302
CJM0304
CJM0306
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
30
30
30
3600
1800
1200
230/460V
230/460V
230/460V
286JM
286JM
326JM
33.20
34.30
37.50
93.0
93.6
93.0
507
507
784
2,559
2,559
4,113
CJM0402
CJM0404
AEHH8N-JM
AEHH8N-JM
40
40
3600
1800
230/460V
230/460V
324JM
324JM
44.20
46.30
94.1
94.1
694
694
3,317
3,295
CJM0502
CJM0504
AEHH8N-JM
AEHH8N-JM
50
50
3600
1800
230/460V
230/460V
326JM
326JM
54.70
56.90
94.1
94.5
784
784
4,215
4,157
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - OPTIM® JM
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY TEFC PUMP MOTOR
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B or C, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
NOTE:
TYPE: AEHH8N-JM
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
APPROX. WT.
LBS
LIST
PRICE
CJM00125
CJM00145
CJM00165
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
1
1
1
3600
1800
1200
575V
575V
575V
143JM
143JM
145JM
1.07
1.20
1.38
82.5
85.5
82.5
61
61
68
381
381
473
CJM1/525
CJM1/545
CJM1/565
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
1.5
1.5
1.5
3600
1800
1200
575V
575V
575V
143JM
145JM
182JM
1.60
1.66
2.02
84.0
86.5
87.5
61
68
106
432
431
517
CJM00225
CJM00245
CJM00265
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
2
2
2
3600
1800
1200
575V
575V
575V
145JM
145JM
184JM
2.02
2.22
2.40
86.5
86.5
88.5
68
68
126
465
461
583
CJM00325
CJM00345
CJM00365
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
3
3
3
3600
1800
1200
575V
575V
575V
182JM
182JM
213JM
2.82
2.99
3.22
88.5
89.5
89.5
106
106
186
524
520
818
CJM00525
CJM00545
CJM00565
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
5
5
5
3600
1800
1200
575V
575V
575V
184JM
184JM
215JM
4.58
4.90
4.99
88.5
89.5
91.0
126
126
213
623
586
1,008
CJM7/525
CJM7/545
CJM7/565
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
7.5
7.5
7.5
3600
1800
1200
575V
575V
575V
213JM
213JM
254JM
6.94
7.08
7.67
91.0
91.7
91.0
186
186
325
832
850
1,415
CJM01025
CJM01045
CJM01065
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
10
10
10
3600
1800
1200
575V
575V
575V
215JM
215JM
256JM
9.20
9.28
10.24
91.0
91.7
91.0
213
213
354
997
1,034
1,734
CJM01525
CJM01545
CJM01565
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
15
15
15
3600
1800
1200
575V
575V
575V
254JM
254JM
284JM
13.28
13.84
14.56
92.4
92.4
92.4
325
325
464
1,364
1,338
2,258
CJM02025
CJM02045
CJM02065
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
20
20
20
3600
1800
1200
575V
575V
575V
256JM
256JM
286JM
17.52
18.40
19.44
92.4
93.0
91.7
354
354
507
1,745
1,737
2,826
CJM02525
CJM02545
CJM02565
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
25
25
25
3600
1800
1200
575V
575V
575V
284JM
284JM
324JM
22.24
23.28
24.24
92.4
93.6
93.0
464
464
694
2,199
2,174
3,380
CJM03025
CJM03045
CJM03065
AEHH8N-JM
AEHH8N-JM
AEHH8N-JM
30
30
30
3600
1800
1200
575V
575V
575V
286JM
286JM
326JM
26.56
27.44
30.00
93.0
93.6
93.0
507
507
784
2,559
2,559
4,113
CJM04025
CJM04045
AEHH8N-JM
AEHH8N-JM
40
40
3600
1800
575V
575V
324JM
324JM
35.36
37.04
94.1
94.1
694
694
3,317
3,295
CJM05025
CJM05045
AEHH8N-JM
AEHH8N-JM
50
50
3600
1800
575V
575V
326JM
326JM
43.76
45.52
94.1
94.5
784
784
4,215
4,157
(1) Prices subject to change without notice.
(2) For VFD applcations please refer to page D-18.
Motor Products - OPTIM® JM
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 63
FEATURES
MODEL: OPTIM® VH VERTICAL HOLLOW SHAFT WPI
TYPE:
AMRCNH
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Pumps
• Irrigation
PRODUCT OVERVIEW
• 3-400HP
• 3600*, 1800 & 1200 RPM (*Up to 150 HP)
• WPI Enclosure / IP22 Design
• 60Hz, 230V/460V (Usable on 208V), 460V or 575V
• High Thrust Vertical Hollow Shaft with P-Base
• NEMA Premium Efficiency
DESIGN FEATURES
• 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power
• Class F Insulation
• Class B Temperature Rise
• Continuous Duty
• NEMA Design B
• 40˚C Ambient
• Max Elevation 3300ft
MECHANICAL FEATURES
• Guide Bearings: Oversized, Double Shielded Vacuum Degassed Ball Bearings Frames 210TP-280TP and Open Bearings with
Regreaseable Provisions Frames 320TP and Larger
• Thrust Bearings: Re-Greasable Angular Contact 210TP-280TP and Oil Lubricated Angular Contact with Site Glass 320TP and Larger
• Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Sealed Bearings
• Thrust Bearing Oil Requirements: Turbine Oil With a Viscosity of 150 S.S.U. at 100°F for 2P, 300 S.S.U. at 100°F for 4P & 6P Frames
320TP-400TP; 300 S.S.U. at 100°F for 440TP and Larger
• Dynamically Balanced Die-Cast Aluminum Rotor
• Cast Iron Frame, End Brackets, and Main Conduit Box
• Fabricated Steel Drip Cover
• 1045 Carbon Steel Hollow Shaft
• Number of Leads 230/460V: 9 Leads 3-5HP; 12 Leads 7.5-125HP; 6 Leads 150HP and Larger
• Number of Leads 575V: 6 Leads
• Solderless Lug Terminals on All Leads
• Grounding Terminal Inside Main Terminal Box
• Paint System: Phenolic Rust Proof Base with Lacquer Top Coat, Light Gray Munsell N5
• Stainless Steel Nameplate and Rodent Screens
• Metal Flinger at Flange Bracket End 320TP and Larger
• Phenolic Alkyd Resin Varnish and Spray Enamel Coat
• *HPE™ High Pulse Endurance Spike Resistant Wire
• Coupling and Gib Key Included (BX Dimension Required at Time of Order)
• Standard Non-Reverse Ratchet with Heavy Duty Stainless Steel Balls
• Space Heater Terminated in Main Terminal Box
• CCW Rotation when Viewed from Top
• Optional Steady Bushing
OTHER FEATURES
• CSA Certified & UL listed
• *Meets NEMA MG1 Part 31.4.4.2
• *Inverter Duty Speed Range: 450 RPM to Rated RPM, S.F.=1.0
• UL Listed (UL 1004-5) for Fire Pump Applications
* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per
NEMA MG1, Part 31.4.4.
A - 64
Motor Products - OPTIM® VH
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY WPI PUMP MOTOR
HIGH THRUST VERTICAL HOLLOW SHAFT
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
Effective 02-11-16
Supercedes All Previous
TYPE: AMRCNH
VOLTAGE: 230/460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
DOWN
THRUST LBS
APPROX.
WT. LBS
LIST
PRICE
VCN0036
AMRCNH
3
1200
230/460V
213TP
4.60
88.5
2950
*
2,496
VCN0056
AMRCNH
5
1200
230/460V
215TP
7.17
89.5
2950
*
2,617
VCN7/54
VCN7/56
AMRCNH
AMRCNH
8
8
1800
1200
230/460V
230/460V
213TP
254TP
9.53
10.1
91.0
90.2
2600
3850
*
*
2,462
3,255
VCN0102
VCN0104
VCN0106
AMRCNH
AMRCNH
AMRCNH
10
10
10
3600
1800
1200
230/460V
230/460V
230/460V
213TP
215TP
256TP
12.2
12.2
12.8
89.5
91.7
91.7
2000
2600
3850
*
*
*
2,487
2,605
3,434
VCN0152
VCN0154
VCN0156
AMRCNH
AMRCNH
AMRCNH
15
15
15
3600
1800
1200
230/460V
230/460V
230/460V
215TP
254TP
284TP
17.9
18.2
19.1
90.2
93.0
91.7
2000
3350
3850
*
*
*
2,645
3,106
3,979
VCN0202
VCN0204
VCN0206
AMRCNH
AMRCNH
AMRCNH
20
20
20
3600
1800
1200
230/460V
230/460V
230/460V
254TP
256TP
286TP
22.9
24.3
24.9
91.0
93.0
92.4
2700
3350
3850
*
*
*
3,025
3,347
4,349
VCN0252
VCN0254
VCN0256
AMRCNH
AMRCNH
AMRCNH
25
25
25
3600
1800
1200
230/460V
230/460V
230/460V
256TP
284TP
324TP
28.1
29.4
30.3
91.7
93.6
93.0
2700
3350
6000
*
*
*
3,289
4,167
6,697
VCN0302
VCN0304
VCN0306
AMRCNH
AMRCNH
AMRCNH
30
30
30
3600
1800
1200
230/460V
230/460V
230/460V
284TP
286TP
326TP
34.0
34.7
35.9
91.7
94.1
93.6
2700
3350
6000
*
*
*
3,955
4,365
7,116
VCN0402
VCN0404
VCN0406
AMRCNH
AMRCNH
AMRCNH
40
40
40
3600
1800
1200
230/460V
230/460V
230/460V
286TP
324TP
364TP
44.8
46.3
45.7
92.4
94.1
94.1
2700
5700
6600
*
*
*
4,162
6,335
8,537
VCN0502
VCN0504
VCN0506
AMRCNH
AMRCNH
AMRCNH
50
50
50
3600
1800
1200
230/460V
230/460V
230/460V
324TP
326TP
365TP
55.9
58.3
57.8
93.0
94.5
94.1
4600
5700
6600
*
*
*
6,576
6,658
9,087
VCN0602
VCN0604
VCN0606
AMRCNH
AMRCNH
AMRCNH
60
60
60
3600
1800
1200
230/460V
230/460V
230/460V
326TP
364TP
404TP
66.7
69.6
69.5
93.6
95.0
94.5
4600
6000
9000
*
*
*
6,826
8,069
12,299
VCN0752
VCN0754
VCN0756
AMRCNH
AMRCNH
AMRCNH
75
75
75
3600
1800
1200
230/460V
230/460V
230/460V
364TP
365TP
405TP
82.9
86.0
85.9
93.6
95.0
94.5
5000
6000
9000
*
*
*
7,886
8,352
12,887
VCN1002
VCN1004
VCN1006
AMRCNH
AMRCNH
AMRCNH
100
100
100
3600
1800
1200
230/460V
230/460V
230/460V
365TP
404TP
444TP
111
115
120
93.6
95.4
95.0
5000
7900
12000
*
*
1800
8,344
11,833
14,577
VCN1252
VCN1254
VCN1256
AMRCNH
AMRCNH
AMRCNH
125
125
125
3600
1800
1200
230/460V
230/460V
230/460V
404TP
405TP
445TP
138
145
150
94.1
95.4
95.0
5000
7900
11900
*
*
1840
11,759
12,283
15,022
* Please contact your local TWMI sales representative for more information.
NOTE:
(1)
(2)
(3)
(4)
(5)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated only (460V).
Please specify coupling diameter (BX dimension) at time of order (see page B-9).
For available accessories please refer to pages B-9 through B-11.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® VH
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 65
LIST PRICES
PREMIUM EFFICIENCY WPI PUMP MOTOR
HIGH THRUST VERTICAL HOLLOW SHAFT
NEMA Standard 3-Phase Motors
60Hz, 230V/460V (Usable on 208V) or 460V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
TYPE: AMRCNH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 460V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
460V
F/L
EFF.
DOWN
THRUST LBS
APPROX.
WT. LBS
LIST
PRICE
VCN1502
VCN1504
VCN1506
AMRCNH
AMRCNH
AMRCNH
150
150
150
3600
1800
1200
460V
460V
460V
405TP
444TP
445TP
165
170
178
94.1
95.8
95.4
5000
10700
11800
*
1830
1970
12,045
16,716
15,909
VCN2004
VCN2006
AMRCNH
AMRCNH
200
200
1800
1200
460V
460V
445TP
447TP
225
236
95.8
95.4
10700
14900
1980
2660
17,150
23,579
VCN2504
VCN2506
AMRCNH
AMRCNH
250
250
1800
1200
460V
460V
445TP20
447TP
283
295
95.8
95.4
13400
14700
2440
2980
21,847
25,608
VCN3004
AMRCNH
300
1800
460V
447TP
335
95.8
13400
2670
23,140
VCN3504
AMRCNH
350
1800
460V
447TP
388
95.8
13300
2800
23,927
VCN4004
AMRCNH
400
1800
460V
449TP
442
95.8
13200
3070
26,784
* Please contact your local TWMI sales representative for more information.
NOTE:
A - 66
(1)
(2)
(3)
(4)
(5)
Prices subject to change without notice.
Ratings over 125HP are single voltage rated only (460V).
Please specify coupling diameter (BX dimension) at time of order (see page B-9).
For available accessories please refer to pages B-9 through B-11.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® VH
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PREMIUM EFFICIENCY WPI PUMP MOTOR
HIGH THRUST VERTICAL HOLLOW SHAFT
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
TYPE: AMRCNH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
DOWN
THRUST LBS
APPROX.
WT. LBS
LIST
PRICE
VCN00365
AMRCNH
3
1200
575V
213TP
3.68
88.5
2950
*
2,496
VCN00565
AMRCNH
5
1200
575V
215TP
5.73
89.5
2950
*
2,617
VCN7/545
VCN7/565
AMRCNH
AMRCNH
8
8
1800
1200
575V
575V
213TP
254TP
7.62
8.09
91.0
90.2
2600
3850
*
*
2,462
3,255
VCN01025
VCN01045
VCN01065
AMRCNH
AMRCNH
AMRCNH
10
10
10
3600
1800
1200
575V
575V
575V
213TP
215TP
256TP
9.79
9.72
10.3
89.5
91.7
91.7
2000
2600
3850
*
*
*
2,487
2,605
3,434
VCN01525
VCN01545
VCN01565
AMRCNH
AMRCNH
AMRCNH
15
15
15
3600
1800
1200
575V
575V
575V
215TP
254TP
284TP
14.3
14.6
15.3
90.2
93.0
91.7
2000
3350
3850
*
*
*
2,645
3,106
3,979
VCN02025
VCN02045
VCN02065
AMRCNH
AMRCNH
AMRCNH
20
20
20
3600
1800
1200
575V
575V
575V
254TP
256TP
286TP
18.3
19.4
19.9
91.0
93.0
92.4
2700
3350
3850
*
*
*
3,025
3,347
4,349
VCN02525
VCN02545
VCN02565
AMRCNH
AMRCNH
AMRCNH
25
25
25
3600
1800
1200
575V
575V
575V
256TP
284TP
324TP
22.4
23.5
24.3
91.7
93.6
93.0
2700
3350
6000
*
*
*
3,289
4,167
6,697
VCN03025
VCN03045
VCN03065
AMRCNH
AMRCNH
AMRCNH
30
30
30
3600
1800
1200
575V
575V
575V
284TP
286TP
326TP
27.2
27.8
28.8
91.7
94.1
93.6
2700
3350
6000
*
*
*
3,955
4,365
7,116
VCN04025
VCN04045
VCN04065
AMRCNH
AMRCNH
AMRCNH
40
40
40
3600
1800
1200
575V
575V
575V
286TP
324TP
364TP
35.8
37.0
36.6
92.4
94.1
94.1
2700
5700
6600
*
*
*
4,162
6,335
8,537
VCN05025
VCN05045
VCN05065
AMRCNH
AMRCNH
AMRCNH
50
50
50
3600
1800
1200
575V
575V
575V
324TP
326TP
365TP
44.7
46.6
46.3
93.0
94.5
94.1
4600
5700
6600
*
*
*
6,576
6,658
9,087
VCN06025
VCN06045
VCN06065
AMRCNH
AMRCNH
AMRCNH
60
60
60
3600
1800
1200
575V
575V
575V
326TP
364TP
404TP
53.4
55.7
55.6
93.6
95.0
94.5
4600
6000
9000
*
*
*
6,826
8,069
12,299
VCN07525
VCN07545
VCN07565
AMRCNH
AMRCNH
AMRCNH
75
75
75
3600
1800
1200
575V
575V
575V
364TP
365TP
405TP
66.3
68.8
68.7
93.6
95.0
94.5
5000
6000
9000
*
*
*
7,886
8,352
12,887
VCN10025
VCN10045
VCN10065
AMRCNH
AMRCNH
AMRCNH
100
100
100
3600
1800
1200
575V
575V
575V
365TP
404TP
444TP
88.4
92.0
96.0
93.6
95.4
95.0
5000
7900
12000
*
*
1800
8,344
11,833
14,577
VCN12525
VCN12545
VCN12565
AMRCNH
AMRCNH
AMRCNH
125
125
125
3600
1800
1200
575V
575V
575V
404TP
405TP
445TP
110
116
120
94.1
95.4
95.0
5000
7900
11900
*
*
1840
11,759
12,283
15,022
* Please contact your local TWMI sales representative for more information.
NOTE:
(1)
(2)
(3)
(4)
Prices subject to change without notice.
Please specify coupling diameter (BX dimension) at time of order (see page B-9).
For available accessories please refer to pages B-9 through B-11.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® VH
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
A - 67
LIST PRICES
PREMIUM EFFICIENCY WPI PUMP MOTOR
HIGH THRUST VERTICAL HOLLOW SHAFT
NEMA Standard 3-Phase Motors
60Hz, 575V
NEMA Design B, Continuous Duty
Class F Insulation, 40°C Ambient, 1.15 S.F.
HPE™ Inverter Duty Wire
TYPE: AMRCNH
Effective 02-11-16
Supercedes All Previous
VOLTAGE: 575V
CATALOGUE NUMBER
TYPE
HP
RPM
VOLTAGE
FRAME
F.L. AMPS
575V
F/L
EFF.
DOWN
THRUST LBS
APPROX.
WT. LBS
LIST
PRICE
VCN15025
VCN15045
VCN15065
AMRCNH
AMRCNH
AMRCNH
150
150
150
3600
1800
1200
575V
575V
575V
405TP
444TP
445TP
132
136
142
94.1
95.8
95.4
5000
10700
11800
*
1830
1970
12,045
16,716
15,909
VCN20045
VCN20065
AMRCNH
AMRCNH
200
200
1800
1200
575V
575V
445TP
447TP
180
189
95.8
95.4
10700
14900
1980
2660
17,150
23,579
VCN25045
VCN25065
AMRCNH
AMRCNH
250
250
1800
1200
575V
575V
445TP20
447TP
226
236
95.8
95.4
13400
14700
2440
2980
21,847
25,608
VCN30045
AMRCNH
300
1800
575V
447TP
268
95.8
13400
2670
23,140
VCN35045
AMRCNH
350
1800
575V
447TP
310
95.8
13300
2800
23,927
VCN40045
AMRCNH
400
1800
575V
449TP
354
95.8
13200
3070
26,784
* Please contact your local TWMI sales representative for more information.
NOTE:
A - 68
(1)
(2)
(4)
(5)
Prices subject to change without notice.
Please specify coupling diameter (BX dimension) at time of order (see page B-9).
For available accessories please refer to pages B-9 through B-11.
For VFD applcations please refer to page D-18.
Motor Products - OPTIM® VH
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
C-FLANGE KITS
TEFC - CAST-IRON
FRAME
OPTIM® TEFC / GLOBAL XPE
CATALOGUE NUMBER
LIST PRICE
ADVANTAGE PLUS IEEE READY
CATALOGUE NUMBER
LIST PRICE
ADVANTAGE PLUS IEEE 841
CATALOGUE NUMBER
LIST PRICE
56
-
-
-
-
-
-
140T
CFE140T
87
CFHH140T
87
CFHB140T
87
180T
CFE180T
102
CFHH180T
102
CFHB180T
102
210T
CFE210T
145
CFHH210T
145
CFHB210T
145
250T
CFE250T
189
CFHH250T
189
CFHB250T
189
280TS
CFE280TS
319
CFHH280
319
CFHB280
319
280T
CFE280T
319
CFHH280
319
CFHB280
319
320TS
CFE320
377
CFHH320
377
CFHB320
377
320T
CFE320
377
CFHH320
377
CFHB320
377
360TS
CFE360TS
406
CFHH360TS
406
CFHB360TS
406
360T
CFE360T
406
CFHH360T
406
CFHB360T
406
400TS
CFE400TS
479
CFHH400TS
479
CFHB400TS
479
400T
CFE400T
479
CFHH400T
479
CFHB400T
479
444TS
CFE440TS
1,277
CFHH440TS
1,277
CFHB440TS
1,277
444T
CFE444/5T
1,277
CFHH444/5T
1,277
CFHB444/5T
1,277
445TS
CFE440TS
1,277
CFHH440TS
1,277
CFHB440TS
1,277
445T
CFE444/5T
1,277
CFHH444/5T
1,277
CFHB444/5T
1,277
447TS
CFE440TS
1,277
CFHH440TS
1,277
CFHB440TS
1,277
447T
CFE447/9T
1,277
CFHH447/9T
1,277
CFHB447/9T
1,277
449TS
CFE440TS
1,277
CFHH440TS
1,277
CFHB440TS
1,277
449T
CFE447/9T
1,277
CFHH447/9T
1,277
CFHB447/9T
1,277
5007A
CFE1698
1,698
-
-
-
-
5007B/C
CFE1698
1,698
-
-
-
-
5009A
CFE1698
1,698
CFHH5009A
1,698
CFHB5009A
1,698
5009B/C
CFE1698
1,698
CFHH5009B/C
1,698
CFHB5009B/C
1,698
5011A
CFE1698
1,698
CFHH5011A
1,698
CFHB5011A
1,698
5011B/C
CFE1698
1,698
CFHH5011B/C
1,698
CFHB5011B/C
1,698
5806B/C
CFE2758
2,758
-
-
-
-
5808A
CFE2758
2,758
-
-
-
-
5808B/C
CFE2758
2,758
CFHH5808B/C
2,758
CFHB5808B/C
2,758
5810A
CFE2758
2,758
-
-
-
-
5810B/C
CFE2758
2,758
CFHH5810B/C
2,758
CFHB5810B/C
2,758
6808A
CFE3048
3,048
-
-
-
-
6808B/C
CFE3048
3,048
-
-
-
-
6810B/C
CFE3048
3,048
-
-
-
-
NOTE:
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B-1
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
C-FLANGE KITS
ODP - CAST-IRON
OPTIM® ODP
FRAME
NOTE:
CATALOGUE NUMBER
56
-
140T
-
180T
-
210T
-
LIST PRICE
250T
CFDH250T
189
280TS
CFDH280TS
319
280T
CFDH280T
319
320TS
CFDH320
377
320T
CFDH320
377
360TS
CFDH360TS
406
360T
CFDH360T
406
400TS
CFDH400TS
479
400T
CFDH400T
479
444TS
CFDH444/5TS
1,277
444T
CFDH444/5T
1,277
445TS
CFDH444/5TS
1,277
445T
CFDH444/5T
1,277
447TS
CFDH447/9TS
1,277
447T
CFDH447/9T
1277
449TS
CFDH447/9TS
1,277
449T
CFDH447/9T
1,277
5009B/C
CFDH5009B/C
1,698
(1) Prices subject to change without notice.
TEFC - ROLLED STEEL
FRAME
NOTE:
B-2
FARM DUTY
ROLLED STEEL TEFC
CATALOGUE NUMBER
LIST PRICE
CATALOGUE NUMBER
LIST PRICE
56
CFS56
77
CFG5614
77
140T
CFS140T
87
CFG5614
77
180T
CFS180T
102
CFGP180T
102
210T
CFS210T
145
CFGP210T
145
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
C-FLANGE KITS
ODP - ROLLED STEEL
FRAME
NOTE:
ROLLED STEEL ODP
CATALOGUE NUMBER
LIST PRICE
56
CFDT5614
77
140T
CFDT5614
77
180T
CFDT180T
102
210T
CFDT210T
145
250T
CFDT250T
189
280TS
CFDT280
319
280T
CFDT280
319
(1) Prices subject to change without notice.
TEXP
FRAME
NOTE:
OPTIM® TEXP
CATALOGUE NUMBER
LIST PRICE
140T
CFXP140T
100
180T
CFXP180T
133
210T
CFXP210T
167
250T
CFXP250T
217
280TS
CFXP280TS
367
280T
CFXP280T
367
320TS
CFXP320
434
320T
CFXP320
434
360TS
CFXP360TS
467
360T
CFXP360T
467
400TS
CFXP400TS
917
400T
CFXP400T
917
444TS
CFXP440TS
1,469
444T
CFXP444/5T
1,469
445TS
CFXP440TS
1,469
445T
CFXP444/5T
1,469
(1) Prices subject to change without notice.
(2) Must be installed by a hazardous locations CSA-Qualified Repair Facility.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B-3
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
BLOWER KITS
NOTE:
B-4
FRAME
CATALOGUE NUMBER
LIST PRICE
140T
BLK140T
221
180T
BLK180T
315
210T
BLK210T
378
250T
BLK250T
551
280T
BLK280T
599
280TS
BLK280TS
599
320T
BLK320T
1,166
360T
BLK360T
1,370
400T
BLK400T
1,418
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
SLIDE BASES
FRAME
CATALOGUE NUMBER
LIST PRICE
FRAME
CATALOGUE NUMBER
LIST PRICE
56
SBS56
25
326T
SB326T
138
143T
SB143T
48
364T
SB364T
175
145T
SB145T
48
365T
SB365T
175
182T
SB182T
52
404T
SB404T
257
184T
SB184T
52
405T
SB405T
257
213T
SB213T
66
444T
SB444T
320
215T
SB215T
66
445T
SB445T
320
254T
SB254T
94
447T
SB447T
438
256T
SB256T
94
449T
SB449T
451
284T
SB284T
103
5007
SB5007
609
286T
SB286T
103
5009
SB5009
609
324T
SB324T
138
-
-
-
NOTE:
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B-5
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
LABYRINTH SEALS
INPRO/SEAL (VBXX)
SELECTION GUIDE
PRO-TECH SEAL
ADVANTAGE PLUS 841
BRG
OPTIM HE PLUS / GLOBAL
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
DE
NDE
DE
NDE
6205/6305
IS05
59
PT05
133
140T
140T
140T
140T
6206/6306
IS06
92
PT06
188
180T
180T/210T
180T
180T/210T
6207/6307
IS07
98
PT07
195
-
250T
-
250T
6208/6308
IS08
107
PT08
202
210T
-
210T
-
6209/6309
IS09
112
PT09
207
250T
-
250T
-
6210/6310
IS10
120
PT10
211
-
280T/280TS
-
280T
6211/6311
IS11
126
PT11
217
280T/280TS
-
280T/280TS
280TS
6212/6312
IS12
140
PT12
224
320T/320TS/360TS
320T/320TS/360TS
320T/320TS/360TS
320T/320TS/360TS
6213/6313
IS13
153
PT13
349
360T/400TS
360T/400T/400TS
360T/400TS
360T/400T/400TS
6214/6314
IS14
471
PT14
368
-
-
444/5TS/447/9TS
444/5TS/447/9TS
6314
IS14B
471
PT14B
373
444/5TS/447/9T
444/5TS/447/9T
-
-
6215/6315
IS15
507
PT15
376
-
-
5000A
5000A
6315
IS15B
507
PT15B
380
5000A
5000A
-
-
6216/6316
IS16
536
PT16
394
-
444/5T/447/9T
-
444/5T/447/9T
6217/6317
IS17
598
PT17
403
400T
-
400T
-
6218/6318
IS18
611
PT18
409
-
-
444/5T
-
6318
IS18B
611
PT18B
413
444/5T
-
-
-
6220/6320
IS20
681
PT20
447
-
-
447/9T
5000BC
6320
IS20B
681
PT20B
472
447/9T
5000BC
-
-
6222/6322
IS22
754
PT22
549
-
-
-
5800BC
6224/6324
IS24
822
PT24
602
-
-
5000BC
-
6322/6324
IS22/24B
754
PT22/24B
602
5000BC
5800BC/6800BC
-
-
6226/6326
IS26
894
PT26
673
-
-
5800BC/6800BC
-
6326
IS26B
894
PT26B
673
5800BC/6800BC
-
-
-
NOTE:
B-6
(1) Prices subject to change without notice.
(2) Inpro/Seals are also available in 303 Stainless Steel, Caplock & Vertical Shaft Up designs.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
SHAFT GROUNDING RINGS
AEGIS (SGR)
NOTE:
BRG
CATALOGUE NUMBER
LIST PRICE
56
SGR56
139
140T
SGR140
148
180T
SGR180
155
210T
SGR210
170
250T, 280TS
SGR2528
201
280T, 320TS, 360TS
SGR2836
264
320T, 400TS
SGR3240
295
360T, 440TS
SGR3644
326
5000A, 5800A, 6800A
SGR5068A
382
400T
SGR400
435
440T
SGR440
607
5000BC
SGR5000
877
5800BC, 6800BC
SGR5868
1,169
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B-7
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
LABYRINTH SEALS C/W SHAFT GROUNDING RINGS
INPRO/SEAL (MGS)
NOTE:
B-8
BRG
CATALOGUE NUMBER
LIST PRICE
6205/6305
IS05MGS
295
6206/6306
IS06MGS
348
6207/6307
IS07MGS
406
6208/6308
IS08MGS
465
6209/6309
IS09MGS
523
6210/6310
IS10MGS
580
6211/6311
IS11MGS
639
6212/6312
IS12MGS
697
6213/6313
IS13MGS
754
6214/6314
IS14MGS
777
6314
IS14MGSB
777
6215/6315
IS15MGS
1,013
6315
IS15MGSB
1,013
6216/6316
IS16MGS
1,073
6217/6317
IS17MGS
1,196
6218/6318
IS18MGS
1,225
6318
IS18MGSB
1,225
6220/6320
IS20MGS
1,364
6320
IS20MGSB
1,364
6222/6322
IS22MGS
1,507
6224/6324
IS24MGS
1,676
6322/6324
IS22/24MGSB
1,507
6226/6326
IS26MGS
1,788
6326
IS26MGSB
1,788
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
COUPLINGS (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)
FRAME
CATALOGUE
NUMBER
BX DIMENSION
LIST PRICE
FRAME
CATALOGUE
NUMBER
BX DIMENSION
LIST PRICE
210TP
CP210-0.751
0.751
205
444/5TP
CP444/5-1.188
1.188
1,703
210TP
CP210-0.876
0.876
205
444/5TP
CP444/5-1.251
1.251
1,703
210TP
CP210-0.938
0.938
205
444/5TP
CP444/5-1.438
1.438
1,703
210TP
CP210-1.001
1.001
205
444/5TP
CP444/5-1.501
1.501
1,703
250/280TP
CP2528-0.751
0.751
236
444/5TP
CP444/5-1.688
1.688
1,703
250/280TP
CP2528-0.876
0.876
236
444/5TP
CP444/5-1.751
1.751
1,703
250/280TP
CP2528-1.001
1.001
236
444/5TP
CP444/5-1.938
1.938
1,703
250/280TP
CP2528-1.188
1.188
236
445TP20 / 447/9TP
CP447/9-1.438
1.438
1,782
250/280TP
CP2528-1.251
1.251
236
445TP20 / 447/9TP
CP447/9-1.501
1.501
1,782
320/360TP
CP3236-1.001
1.001
252
445TP20 / 447/9TP
CP447/9-1.688
1.688
1,782
320/360TP
CP3236-1.188
1.188
252
445TP20 / 447/9TP
CP447/9-1.751
1.751
1,782
320/360TP
CP3236-1.251
1.251
252
445TP20 / 447/9TP
CP447/9-1.938
1.938
1,782
320/360TP
CP3236-1.438
1.438
252
445TP20 / 447/9TP
CP447/9-2.001
2.001
1,782
320/360TP
CP3236-1.501
1.501
252
445TP20 / 447/9TP
CP447/9-2.063
2.063
1,782
400TP
CP400-1.188
1.188
394
445TP20 / 447/9TP
CP447/9-2.126
2.126
1,782
400TP
CP400-1.251
1.251
394
445TP20 / 447/9TP
CP447/9-2.188
2.188
1,782
NOTE:
400TP
CP400-1.438
1.438
394
445TP20 / 447/9TP
CP447/9-2.251
2.251
1,782
400TP
CP400-1.501
1.501
394
445TP20 / 447/9TP
CP447/9-2.376
2.376
1,782
400TP
CP400-1.688
1.688
394
445TP20 / 447/9TP
CP447/9-2.438
2.438
1,782
400TP
CP400-1.751
1.751
394
445TP20 / 447/9TP
CP447/9-2.501
2.501
1,782
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B-9
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
STEADY BUSHING (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)
FRAME
CATALOGUE
NUMBER
BX DIMENSION
LIST PRICE
FRAME
CATALOGUE
NUMBER
BX DIMENSION
LIST PRICE
210TP
SB210-0.938
0.938
79
444/5TP
SB444/5-1.188
1.188
158
210/250TP
SB2125-0.751
0.751
79
444/5TP
SB444/5-1.251
1.251
158
210/250TP
SB2125-0.876
0.876
79
444/5TP
SB444/5-1.438
1.438
158
210/250TP
SB2125-1.001
1.001
79
444/5TP
SB444/5-1.501
1.501
158
250TP
SB250-1.188
1.188
79
444/5TP
SB444/5-1.688
1.688
158
250TP
SB250-1.251
1.251
79
444/5TP
SB444/5-1.751
1.751
158
280TP
SB280-0.751
0.751
95
444/5TP
SB444/5-1.938
1.938
158
280TP
SB280-0.876
0.876
95
445TP20 / 447/9TP
SB447/9-1.438
1.438
173
280TP
SB280-1.001
1.001
95
445TP20 / 447/9TP
SB447/9-1.501
1.501
173
280TP
SB280-1.188
1.188
95
445TP20 / 447/9TP
SB447/9-1.688
1.688
173
280TP
SB280-1.251
1.251
95
445TP20 / 447/9TP
SB447/9-1.751
1.751
173
320TP
SB320-1.001
1.001
110
445TP20 / 447/9TP
SB447/9-1.938
1.938
173
NOTE:
B - 10
320TP
SB320-1.188
1.188
110
445TP20 / 447/9TP
SB447/9-2.001
2.001
173
320TP
SB320-1.251
1.251
110
445TP20 / 447/9TP
SB447/9-2.063
2.063
173
320TP
SB320-1.438
1.438
110
445TP20 / 447/9TP
SB447/9-2.126
2.126
173
320TP
SB320-1.501
1.501
110
445TP20 / 447/9TP
SB447/9-2.188
2.188
173
360TP
SB360-1.001
1.001
126
445TP20 / 447/9TP
SB447/9-2.251
2.251
173
360TP
SB360-1.188
1.188
126
445TP20 / 447/9TP
SB447/9-2.376
2.376
173
360TP
SB360-1.251
1.251
126
445TP20 / 447/9TP
SB447/9-2.438
2.438
173
360TP
SB360-1.438
1.438
126
445TP20 / 447/9TP
SB447/9-2.501
2.501
173
360TP
SB360-1.501
1.501
126
400TP
SB400-1.188
1.188
142
400TP
SB400-1.251
1.251
142
400TP
SB400-1.438
1.438
142
400TP
SB400-1.501
1.501
142
400TP
SB400-1.688
1.688
142
400TP
SB400-1.751
1.751
142
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
PARTS & ACCESSORIES
Effective 02-11-16
Supercedes All Previous
ALTERNATE P-FLANGE KITS (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)
NOTE:
FRAME
CATALOGUE NUMBER
LIST PRICE
BASE DIM
AJ
AK
444/5TP
PBVH444/5-16.5
1,640
16.5
14.75
13.5
444/5TP
PBVH444/5-20
1,640
20
14.75
13.5
445TP20
PBVH445TP20-20
1,640
20
14.75
13.5
445TP20
PBVH445TP20-24.5
1,640
24.5
14.75
13.5
447/9TP
PBVH447/9-20
1,766
20
14.75
13.5
447/9TP
PBVH447/9-24.5
1,766
24.5
14.75
13.5
(1) Prices subject to change without notice.
NRR BALL RATCHETS (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)
NOTE:
FRAME
CATALOGUE NUMBER
LIST PRICE
210TP
NRR210TP
851
250TP
NRR250TP
946
280TP
NRR280TP
1,104
320TP
NRR320TP
1,482
360TP
NRR360TP
1,577
400TP
NRR400TP
1,892
444/5TP
NRR444/5TP
3,406
445TP20 / 447/9TP
NRR440TP
3,547
(1) Prices subject to change without notice.
Parts & Accessories
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B - 11
FACTORY MODIFICATIONS
Effective 02-11-16
Supercedes All Previous
MOTOR MODIFICATIONS
MOD.
CODE
MODIFICATION
SUMMARY
LIST PRICE
56
140
180
210
250
280
320
360
400
440
5000
5800
6800
-
-
C1A
C-FLANGE - ODP
-
155
195
264
332
489
570
643
802
1,709 2,323
C1B
C-FLANGE - TEFC
102
155
195
264
332
489
570
643
802
1,709 2,323 3,425 3,764
C2
1,773 2,407 3,509
C-FLANGE WITH INPRO/SEAL (ADV+)
-
161
207
282
350
514
602
679
852
*C3A
D-FLANGE - ODP
-
-
-
-
-
-
-
-
-
-
-
-
-
*C3B
D-FLANGE - TEFC
-
-
-
-
-
-
-
-
-
-
-
-
-
*C4
D-FLANGE WITH INPRO/SEAL (ADV+)
-
-
-
-
-
-
-
-
-
-
-
-
-
C5A
INPRO/SEAL DE
169
210
276
294
329
381
547
611
C5B
INPRO/SEAL NDE
180
222
290
317
333
396
581
650
C5C
SPECIAL INPRO/SEAL DE (ADV+ 841)
-
177
260
264
301
347
446
499
C5D
SPECIAL INPRO/SEAL NDE (ADV+ 841)
-
184
266
287
292
348
462
519
597
C5E
PROTECH SEAL DE (ADV+ 841)
-
223
288
321
345
380
468
632
738
907
1,204 1,313
-
C5F
PROTECH NDE (ADV+ 841)
-
230
295
316
341
382
484
652
729
848
1,120 1,281
-
C6
F2 CONVERSION
54
68
86
107
129
157
204
248
323
432
2,527 2,570 2,618
C7
SPACE HEATERS (CSA CERTIFIED)
-
327
361
402
436
477
511
582
696
C8
THERMISTER 1/PH
-
287
324
364
399
439
474
530
618
755
1,357 1,400 1,448
C9
KLIXONS 1/PH
-
314
349
389
424
464
499
555
646
780
1,395 1,438 1,486
C10A
AUXILIARY BOX
-
652
663
677
688
702
484
500
550
621
C10B
AUXILIARY BOX F2 SIDE
-
737
759
787
834
862
897
941
C11
INSULATED NDE BEARING
C12
STAINLESS STEEL HARDWARE
-
68
84
107
129
C13A
WINDING RTD 2/PH
-
C13B
WINDING RTD 1/PH
-
1,100 1,309 1,889 2,040 2,088
757
1,235 1,811 1,932 1,980
1,157 1,370 1,667 1,872
1,206 1,584 1,744
-
1,046 1,688 1,731 1,779
827
870
918
1,028 1,177 1,634 1,677 1,725
SEE BEARING TABLE
157
179
209
270
369
625
668
716
1,746 1,768 1,796 1,856 1,884 1,995 2,166 2,241 2,350 2,916 2,959 3,007
977
999
1,027 1,074 1,102 1,227 1,287 1,362 1,471 1,984 2,027 2,075
C14
BEARING RTD 1/BRG
-
-
-
-
C15A
RTD AUXILIARY BOX
-
571
582
596
1,972 2,027 2,077 2,148 2,250 2,387 2,863 2,906 2,954
C15B
RTD AUXILIARY BOX F2 SIDE
-
946
968
996
C16
REMOVE FEET
197
225
297
371
472
541
654
607
621
632
779
829
900
1,095 1,138 1,186
1,084 1,112 1,134 1,239 1,314 1,423 1,875 1,918 1,966
1,016 1,218 1,455
-
C17A
OVERSIZED TERMINAL BOX - STD
-
309
347
432
486
514
604
788
973
C17B
OVERSIZED TERMINAL BOX - TYPE II
-
-
-
-
-
-
-
-
-
2,896
957
C18
TERMINAL BLOCK MAIN TERMINAL BOX
-
323
347
373
513
527
613
707
850
971
-
C19
CONVERT BEARINGS: BALL TO ROLLER
SEE BEARING TABLE
C20
CONVERT BEARINGS: ROLLER TO BALL
SEE BEARING TABLE
-
-
1,130 1,495 1,727 1,932
1,000 1,048
-
-
* D-Flanges not available from stock, please contact TWMI for factory lead time.
NOTE:
B - 12
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Lead times vary depending on the modification requested.
All prices to be based on “Stock Product Modification Procedures #TWMI-M1”.
Auxiliary Boxes are always to be priced as separate mods.
Prices shown are TWMI’s list prices, standard motor multiplier applies for the motor being modified.
Please contact your TWMI representative for a discount when performing multiple modifications to one motor.
Please contact your TWMI representative for pricing on mods not listed.
Effective November 1, 2010 prices are subject to change without notice.
Refer to Factory Modification Descriptions for more accurate details on each modification.
All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification
Procedures #TWMI-M1”.
Factory Modifications
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FACTORY MODIFICATIONS
Effective 02-11-16
Supercedes All Previous
MOTOR MODIFICATIONS
LIST PRICE
MOD.
CODE
MODIFICATION
SUMMARY
56
140
180
210
250
280
320
C21A
CUSTOM SHAFT - MODIFY EXISTING SHAFT
565
616
654
712
772
843
949
C21B
CUSTOM SHAFT - REPLACE EXISTING SHAFT
C21C
STUB SHAFT FOR SHAFT MOUNTED
ENCODERS
372
400
422
484
540
614
681
793
914
C22
SPECIAL GREASE
222
275
336
364
488
516
640
734
809
918
C23
NAMEPLATE CHANGE
20
20
20
20
20
20
20
20
20
23
23
23
23
C24
ADDITIONAL NAMEPLATE - INFORMATION
PLATE
20
20
20
20
20
20
20
20
20
20
20
20
20
C25
GROUND PROVISION
93
107
118
132
179
193
204
273
323
394
561
604
652
C26A
BREATHER DRAIN PLUGS
106
134
168
202
238
266
288
332
407
516
998
C26B
DRAIN HOLES DE (NO THREADS/BREATHER
DRAINS)
50
64
75
89
100
114
125
141
191
262
391
434
482
C26C
DRAIN HOLES NDE (NO THREADS/
BREATHER DRAINS)
77
105
127
155
177
205
227
271
346
455
841
884
932
C27
TROPICALIZATION- FUNGUS/CORROSION
PROTECTION
95
134
206
234
309
337
409
453
580
689
C28
CHANGE ROTATION
-
-
-
-
-
-
-
-
-
-
829
872
920
C29
CHANGE COOLING FAN (FAN NOT INCL.)
66
80
104
130
154
180
204
248
334
444
636
679
727
C30
JACKING BOLTS
-
152
170
184
225
239
295
316
457
591
932
975
1,023
436
491
550
584
928
-
-
-
-
-
-
QUOTE
QUOTE
QUOTE
360
400
440
5000
5800
6800
1,053 1,293 1,532 2,170 2,213 2,261
1,418 1,446 1,695 1,950 2,199 2,909 3,840 5,021 5,573 6,546 17,409 18,361 20,227
1,068 1,727 1,770 1,818
C31A
DRIP COVER
241
255
270
289
379
C31B
DRIP COVER C/W VERTICAL LIFTING LUGS
820
709
770
834
947
C32
SUN-SHIELD
QUOTE
QUOTE
QUOTE
QUOTE
QUOTE
QUOTE
QUOTE
QUOTE
QUOTE
QUOTE
C33
VIBRATION TEST & REPORT AS PER IEEE841
170
184
195
209
297
311
384
400
593
664
C34
1,027 1,104 1,209 1,266 1,723
1,407 1,450 1,498
1,041 1,089
1,125 1,168 1,216
1,136 1,179 1,227
BALANCE ROTOR TO IEEE841 STANDARDS
372
400
445
496
563
625
681
771
880
C35A
SHAFT GROUNDING BRUSH (CARBON TYPE)
195
209
245
259
400
414
486
502
-
-
-
-
-
C35B
SHAFT GROUND RING
316
339
368
407
504
623
743
834
1054
1307
1763
2084
2132
C35C
SHAFT GROUND SEAL (ADV+)
-
358
422
543
612
740
873
957
1,418 1,669 2,005 2,262
C36A
SPECIAL PAINT - COLOR (STANDARD PAINT)
175
211
245
282
361
432
500
573
736
1,034 1,368 1,411 1,459
C36B
SPECIAL PAINT - EPOXY
175
211
245
282
361
432
500
573
736
1,034 1,368 1,411 1,459
C37
CONVERT TO 3 LEAD MOTOR
190
218
263
337
404
477
545
634
755
C38
EXTEND MAIN LEADS
281
321
388
450
529
614
931
C39
CHANGE BEARINGS TO ZZ TYPE
-
189
246
298
414
573
618
710
-
-
-
C40
DE-RATE HP
20
20
20
20
20
20
20
20
20
20
20
20
20
C41
RE-RATE TO 50HZ
20
20
20
20
20
20
20
20
20
20
20
20
20
C42
LOW TEMP -50°C
-
659
818
850
989
NOTE:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
1,068 2,977 3,020 3,068
909
1,066 1,187 1,341
1,095 1,533
-
1,523 1,566 1,614
-
-
-
1,063 1,228 1,373 1,875 2,635 3,584 3,813 3,861
Lead times vary depending on the modification requested.
All prices to be based on “Stock Product Modification Procedures #TWMI-M1”.
Auxiliary Boxes are always to be priced as separate mods.
Prices shown are TWMI’s list prices, standard motor multiplier applies for the motor being modified.
Please contact your TWMI representative for a discount when performing multiple modifications to one motor.
Please contact your TWMI representative for pricing on mods not listed.
Effective November 1, 2010 prices are subject to change without notice.
Refer to Factory Modification Descriptions for more accurate details on each modification.
All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification
Procedures #TWMI-M1”.
Factory Modifications
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B - 13
FACTORY MODIFICATIONS
Effective 02-11-16
Supercedes All Previous
MOTOR MODIFICATIONS
MOD.
CODE
MODIFICATION
SUMMARY
LIST PRICE
56
140
180
210
250
280
555
677
709
826
926
C43A
CONVERT IEEE READY TO IEEE 841
-
C43B
CONVERT STANDARD TEFC TO IEEE 841
-
C44
LOCKED DE BRG
C45
CLASS H INSULATION
C46
CONNECT MOTOR FOR WYE-DELTA
STARTING
482
496
507
748
986
C47
VERTICAL LIFTING LUGS
482
496
552
611
645
NOTE:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
320
360
400
440
5000
5800
6800
1,328 1,445 2,134 2,753 4,123 4,352
-
1,377 1,634 1,773 2,162 2,413 3,012 3,343 4,289 5,287 8,923 9,152
-
190
230
309
337
404
455
568
657
778
909
1,190 1,446 1,695 1,837 1,972 2,796 4,749 6,157 9,414 13,159
1,568 1,611 1,659
-
-
-
1,227 1,466 1,709 1,986 2,512 3,777 3,820 3,868
682
716
777
850
1,034
-
-
-
Lead times vary depending on the modification requested.
All prices to be based on “Stock Product Modification Procedures #TWMI-M1”.
Auxiliary Boxes are always to be priced as separate mods.
Prices shown are TWMI’s list prices, standard motor multiplier applies for the motor being modified.
Please contact your TWMI representative for a discount when performing multiple modifications to one motor.
Please contact your TWMI representative for pricing on mods not listed.
Effective November 1, 2010 prices are subject to change without notice.
Refer to Factory Modification Descriptions for more accurate details on each modification.
All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification
Procedures #TWMI-M1”.
HAZARDOUS LOCATION MODIFICATIONS
LIST PRICE
MOD.
CODE
MODIFICATION
SUMMARY
56
140
180
H1
CSA CERTIFIED DIVISION 1 SPACE HEATERS
-
941
974
H2
F2 CONVERSION XP
-
212
234
262
334
362
461
505
H3
INSTALL C-FLANGE XP
-
268
316
377
563
657
707
843
H4
NAMEPLATE CHANGE HAZLOC
-
57
57
57
57
57
107
107
107
HA
EXPLOSION PROOF ADDER
(WHEN APPROVED)
-
614
614
614
614
614
773
773
773
NOTE:
B - 14
210
250
280
320
360
400
440
5000
5800
6800
-
-
-
-
-
-
-
-
-
109
-
-
-
773
-
-
-
1,016 1,049 1,091 1,284 1,355 1,468 1,818
630
739
1,388 1,459
(1) All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification
Procedures #TWMI-M1”.
Factory Modifications
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FACTORY MODIFICATIONS
Effective 02-11-16
Supercedes All Previous
BEARING MODIFCATIONS
BEARING TABLES
C19 - CONVERT BEARINGS: BALL TO ROLLER
C20 - CONVERT BEARINGS: ROLLER TO BALL
BEARING CODE
LIST PRICE
BEARING CODE
LIST PRICE
6312 - NU312
1,227
NU312 - 6312
845
6313 - NU313
1,400
NU313 - 6313
952
6314 - NU614
1,711
NU314 - 6314
1,266
6315 - NU315
2,352
NU315 - 6315
1,780
6317 - NU317
2,050
NU317 - 6317
1,345
6318 - NU318
2,223
NU318 - 6318
1,584
6320 - NU320
2,989
NU320 - 6320
2,095
6324 - NU324
4,977
NU324 - 6324
4,527
6326 - NU326
6,409
NU326 - 6326
5,898
C11 - INSULATED NDE BEARING
NOTE:
BEARING CODE
LIST PRICE
BEARING CODE
LIST PRICE
6205C3/INS
TBA
6314C3/INS
2,688
6211C3/INS
TBA
6315C3/INS
3,544
6212C3/INS
3,110
6316C3/INS
3,017
6213C3/INS
TBA
6318C3/INS
3,290
6306C3/INS
TBA
6320C3/INS
3,659
6307C3/INS
TBA
6322C3/INS
4,977
6310C3/INS
2,118
6324C3/INS
5,161
6313C3/INS
2,669
6326C3/INS
5,726
(1) All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification
Procedures #TWMI-M1”.
(2) Insulated Bearings supplied by TECO - Air Freight From Germany included in price.
Factory Modifications
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B - 15
FACTORY MODIFICATION DESCRIPTIONS
Effective 02-11-16
Supercedes All Previous
MOTOR MODIFICATION DESCRIPTIONS
MOD.
CODE
MODIFICATION SUMMARY
DESCRIPTION
C1A
C-FLANGE - ODP
Remove DE bracket and install C-Flange on ODP motor: modification price includes the C-Flange.
C1B
C-FLANGE - TEFC
Remove DE bracket and install C-Flange on TEFC motor: modification price includes the C-Flange.
C2
C-FLANGE WITH INPRO/SEAL (ADV+)
Remove DE bracket and Inpro/Seal; install C-Flange with Inpro/Seal on TEFC motor: modification
price includes the C-Flange.
C3A
D-FLANGE - ODP
Remove DE bracket and install D-Flange on ODP motor: modification price includes the D-Flange.
C3B
D-FLANGE - TEFC
Remove DE bracket and install D-Flange on TEFC motor: modification price includes the D-Flange.
C4
D-FLANGE WITH INPRO/SEAL (ADV+)
Remove DE bracket and Inpro/Seal; install D-Flange with Inpro/Seal on TEFC motor: modification
price includes the D-Flange.
C5A
INPRO/SEAL DE
Remove DE bracket, machine shaft opening and install Inpro/Seal: modification price includes
Inpro/Seal.
C5B
INPRO/SEAL NDE
Remove NDE bracket, machine shaft opening and install Inpro/Seal: modification price includes
Inpro/Seal.
C5C
SPECIAL INPRO/SEAL DE (ADV+ 841)
Remove DE Inpro/Seal and install new special purpose Inpro/Seal. Use for vertical seal or special
seal: modification price includes Inpro/Seal.
C5D
SPECIAL INPRO/SEAL NDE (ADV+ 841)
Remove NDE Inpro/Seal and install new special purpose Inpro/Seal. Use for vertical seal or special
seal: modification price includes Inpro/Seal.
C5E
PROTECH SEAL DE (ADV+ 841)
Remove DE Inpro/Seal and install protech seal: modification price includes protech seal.
C5F
PROTECH NDE (ADV+ 841)
Remove NDE Inpro/Seal and install protech seal: modification price includes protech seal.
C6
F2 CONVERSION
Convert terminal box location from standard F1 to F2, or F2 to F1, depending on the product line.
on medium voltage motors, The auxiliary terminal boxes will be on the opposite side as the main
terminal box as standard. If the requirement is to have all terminal boxes on either the F1 or F2 side,
please specify.
C7
SPACE HEATERS (CSA CERTIFIED)
Install wire wound rubber space heater(s) with leads terminated in main terminal box; if auxiliary
terminal box is required see mod C10. Standard voltage is 115V; however other voltages are
available. Heaters are CSA certified for Class I, Division 2 areas.
C8
THERMISTER 1/PH
Install three PTC thermistors (155°c), one per phase, on the winding end turns with leads brought
out to main terminal box; if auxiliary terminal box is required see mod C10.
C9
KLIXONS 1/PH
Install three normally closed thermostats (140°c), one per phase connected in series, on the winding
end turns with leads brought out to the main terminal box; if auxiliary terminal box is required see
mod C10.
C10A
AUXILIARY BOX
Mount auxiliary terminal box on NDE side of the main terminal box. Includes box and terminal strip
with four terminals.
C10B
AUXILIARY BOX F2 SIDE
Mount auxiliary terminal box on F2 side of the motor. Includes box and terminal strip with four
terminals.
C11
INSULATED NDE BEARING
Remove standard NDE bearing and replace with an electrically insulating bearing to eliminate stray
electric currents.
C12
STAINLESS STEEL HARDWARE
Remove existing plated hardware and replace with stainless steel.
C13A
WINDING RTD 2/PH
Install six 100Ω platinum surface mount RTD’s, two per phase, on the winding end turns with leads
brought out to the main terminal box; if RTD auxiliary terminal box is required see mod C15.
C13B
WINDING RTD 1/PH
Install three 100Ω platinum surface mount RTD’s, one per phase, on the winding end turns with
leads brought out to the main terminal box; if RTD auxiliary terminal box is required see mod C15.
C14
BEARING RTD 1/BRG
Install two 100Ω platinum bearing RTD’s, one per bearing with leads brought out to the main
terminal box; if RTD auxiliary terminal box is required see mod C15.
C15A
RTD AUXILIARY BOX
Mount RTD auxiliary terminal box on DE side of the main terminal box. Includes box and two
terminal strips with 12 terminals each.
C15B
RTD AUXILIARY BOX F2 SIDE
Mount RTD auxiliary terminal box on F2 side of the motor. Includes box and two terminal strips with
12 terminals each.
B - 16
Factory Modification Descriptions
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FACTORY MODIFICATION DESCRIPTIONS
Effective 02-11-16
Supercedes All Previous
MOTOR MODIFICATION DESCRIPTIONS
MOD.
CODE
MODIFICATION SUMMARY
DESCRIPTION
REMOVE FEET
Remove feet off horizontal mount T-Frame motor to create a round body type motor. Vertical lifting
lugs can be added at additional cost.
C17A
OVERSIZED TERMINAL BOX - STD
Replace existing terminal box with an oversized main terminal box. Pricing is based on the terminal
box that is standard for the next larger frame size.
C17B
OVERSIZED TERMINAL BOX - TYPE II
Replace existing terminal box with an oversized nema Type II main terminal box.
C18
TERMINAL BLOCK MAIN TERMINAL BOX
Install IEC style terminal block in the main terminal box and connect for requested voltage.
C19
CONVERT BEARINGS: BALL TO ROLLER
Convert standard bearing on DE from ball bearing to roller bearing.
C20
CONVERT BEARINGS: ROLLER TO BALL
Convert standard bearing on DE from roller bearing to ball bearing, machine work is required allow
for thermal growth.
C21A
CUSTOM SHAFT - MODIFY EXISTING
SHAFT
Modify existing shaft to meet customer requirements. A drawing must be submittted and approved
by both TWMI and the customer. This mod includes TS shafts, shortened shafts, smaller diameter
shafts etc.
C21B
CUSTOM SHAFT - REPLACE EXISTING
SHAFT
Replace existing shaft to meet customer requirements. A drawing must be submittted and
approved by both TWMI and the customer. This mod includes 4140 shafts, double shafts, JM shafts
etc.
C21C
STUB SHAFT FOR SHAFT MOUNTED
ENCODERS
Modify NDE with stub shaft and provisions to mount encoder. (Encoder not included, contact TWMI
for pricing if required).
C22
SPECIAL GREASE
Remove standard grease from bearings, end brackets and inlet tubes. Purge and repack with
specified grease type.
C23
NAMEPLATE CHANGE
Add new nameplate displaying approved data changes such as new voltage and frequency, revised
HP and service factor, higher or lower ambient temperature, etc. Use this for adder for XP motors
when modifications are being performed in addition to the nameplate change (H4).
C24
ADDITIONAL NAMEPLATE INFORMATION PLATE
Add second data plate with customer part number, order number, or other data.
C25
GROUNDING PROVISION
Drill and tap the motor frame to accept ground lug. All motors have a grounding lug inside the
main lead box as a standard. Lug not included in price.
C26A
BREATHER DRAIN PLUGS
Install stainless steel breather drain plugs where required.
C26B
DRAIN HOLES DE (NO THREADS/
BREATHER DRAINS)
Drill drain holes in DE for vertical mounting. (No threads/breather drains)
C26C
DRAIN HOLES NDE (NO THREADS/
BREATHER DRAINS)
Drill drain holes in NDE for vertical mounting. (No threads/breather drains)
C27
TROPICALIZATION - FUNGUS/
CORROSION PROTECTION
Spray the internal windings, rotor and end brackets with a fungus proof anti-corrosion coating.
C28
CHANGE ROTATION
Replace unidirectional cooling fan to achieve opposite direction of rotation.
C29
CHANGE COOLING FAN (FAN NOT
INCLUDED)
Replace standard fan with non sparking fan, cast iron fan or other material requested to meet
customer’s requirements. Fan not included in price.
C30
JACKING BOLTS
Drill and tap two holes in the motor feet diagonally from one another to provide provisions for
jacking bolts.
C31A
DRIP COVER
Install fabricated steel drip cover on NDE for vertical motors.
C31B
DRIP COVER C/W VERTICAL LIFTING
LUGS
Install fabricated steel drip cover and lifting lugs on NDE for vertical motors.
C32
SUN-SHIELD
Install sun-shield over motor to protect from excessive heating caused by over exposure to the
sun, typically for use in desert climates. Sun-shield will be priced per motor, contact your TWMI
representative for more information.
C33
VIBRATION TEST & REPORT AS PER
IEEE841
Perform vibration test and send report with motor as outlined in IEEE841 standard.
C34
BALANCE ROTOR TO IEEE841
STANDARDS
Balance rotor to IEEE841 specifications.
C16
Factory Modification Descriptions
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B - 17
FACTORY MODIFICATION DESCRIPTIONS
Effective 02-11-16
Supercedes All Previous
MOTOR MODIFICATION DESCRIPTIONS
MOD.
CODE
MODIFICATION SUMMARY
DESCRIPTION
C35A
SHAFT GROUNDING BRUSH
(CARBON TYPE)
Install carbon brush type shaft grounding device.
C35B
SHAFT GROUND RING
Install shaft grounding ring on DE to reduce or eliminate shaft currents.
C35C
SHAFT GROUND SEAL (ADV+)
Install shaft grounding seal on DE to reduce or eliminate shaft currents.
C36A
SPECIAL PAINT - COLOR
(STANDARD PAINT)
Paint motor with standard type paint with customer specified color.
C36B
SPECIAL PAINT - EPOXY
Standard paint finish will be changed to Epoxy paint system (e.g. Advantage Plus Epoxy Paint).
C37
CONVERT TO 3 LEAD MOTOR
Re-connect motor to 3 leads.
C38
EXTEND MAIN LEADS
Extend existing leads to customer specified length. The splice will be made behind the terminal box
so it is not seen.
C39
CHANGE BEARINGS TO ZZ TYPE
Remove bearings and install ZZ type double sheilded bearings.
C40
DE-RATE HP
De-rate motor HP to lower value, second data plate will be installed showing de-rated motor data.
C41
RE-RATE TO 50HZ
Re-rate motor to 50Hz operation, second data plate will be installed showing re-rated motor data.
C42
LOW TEMP -50°C
Modifiy motor for low temperature operation down to -50°C. Includes spaceheaters terminated in
main box, low temp grease and new nameplate.
C43A
CONVERT IEEE READY TO IEEE 841
Convert Adv+ IEEE Ready motor to Adv+ IEEE 841 specs. Includes inpro seals, vibration test & report,
new nameplate & labor.
C43B
CONVERT STANDARD TEFC TO IEEE 841
Convert standard TEFC motor to Adv+ IEEE 841 specs. Includes inpro seals, paint, hardware,
vibration test & report, new nameplate & labor.
C44
LOCKED DE BRG
Lock DE bearing <.000" endplay.
C45
CLASS H INSULATION
Rewind motor with class H insulation.
C46
CONNECT MOTOR FOR WYE-DELTA
STARTING
Re-connect motor internally to allow for wye-delta starting. *Approval required
C47
VERTICAL LIFTING LUGS
Install vertical lifting lugs on horizontal motor.
HAZARDOUS LOCATION MODIFICATION DESCRIPTIONS
MOD.
CODE
MODIFICATION SUMMARY
DESCRIPTION
H1
CSA CERTIFIED DIVISION 1 SPACE
HEATERS
Install wire wound rubber space heater(s) that are CSA certified for division 1, with leads terminated
in main terminal box. Standard voltage is 115V; however other voltages are available. Please specify
voltage when ordering. All heaters are single phase.
H2
F2 CONVERSION XP
Convert terminal box location from standard F1 to F2 on TEXP motor.
H3
INSTALL C-FLANGE XP
Remove DE bracket and install c-flange on TEXP motor: modification price includes the c-flange &
a new nameplate.
H4
NAMEPLATE CHANGE HAZLOC
Add new nameplate displaying approved data changes such as new voltage and frequency, revised
HP and service factor, higher or lower ambient temperature, etc. This adder is to be used when no
other modifications are being done to the motor, otherwise use C23.
HA
EXPLOSION PROOF ADDER
(WHEN APPROVED)
Additional cost to perform standard modifications to XP motors. Due to CSA regulations only certain
modifications can be done on XP motors, contact your TWMI representative for more information.
B - 18
Factory Modification Descriptions
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FACTORY MODIFICATION REFERENCE
Effective 02-11-16
Supercedes All Previous
BEARING CROSS REFERENCE TABLE
FRAME
56
140T
180T
210T
250T
280T
280TS
320T
320TS
360T
360TS
400T
400TS
444/5T
444/5TS
447/9T
447/9TS
5000A
5000BC
5800A
5800BC
6800A
6800BC
450C
500C
560C
FRAME
56
140T
180T
210T
250T
280T
280TS
320T
320TS
360T
360TS
400T
400TS
444/5T
444/5TS
447/9T
447/9TS
5000A
5000BC
5800A
5800BC
6800A
6800BC
450C
500C
560C
RS TEFC
OPTIM® TEFC
ADVANTAGE PLUS
OPTIM® TEXP
DE
NDE
DE
NDE
DE
NDE
DE
NDE
6205ZZ
6206ZZC3
6208ZZC3
6204ZZ
6205ZZC3
6206ZZC3
6205ZZ
6306ZZ
6308ZZ
6309ZZ
6311ZZ
6211C3
6312
6312C3
6313
6312C3
6317
6313C3
6318
6314C3
6320
6314C3
6315C3
6324C3
6205ZZ
6306ZZ
6306ZZ
6307ZZ
6310ZZ
6211C3
6212
6212C3
6213
6212C3
6313
6313C3
6316
6314C3
6316
6314C3
6315C3
6320
6205ZC3
6306ZC3
6308ZC3
6309ZC3
6311ZC3
6311ZC3
6312ZC3
6312ZC3
6313ZC3
6312ZC3
6317C3
6313C3
6318C3
6314C3
6320C3
6314C3
6315C3
6324C3
6205ZC3
6306ZC3
6306ZC3
6307ZC3
6310ZC3
6310ZC3
6212ZC3
6212ZC3
6213ZC3
6212ZC3
6313ZC3
6313ZC3
6316C3
6314C3
6316C3
6314C3
6315C3
6320C3
6205ZZ
6306ZZ
6308ZZ
6309ZZ
6311ZZ
6211C3
6312
6312C3
6313
6312C3
6317
6313C3
NU318
6313C3
6205ZZ
6306ZZ
6306ZZ
6307ZZ
6310ZZ
6211C3
6212
6212C3
6213
6212C3
6313
6313C3
6318
6313C3
6326C3
6322
6326C3
6322C3
6326C3
6322
GLOBAL XPE
DE
6315C3
6324
6315C3
6326
6315C3
6326
6324
6326
6330
OPTIM® ODP
NDE
6315C3
6320
6315C3
6322
6315C3
6322
6322
6324/C3 VL2071
6326/C3 VL0241
MAX-HT
DE
NDE
NU324C3
6320
NU326C3
6322
ROLLED STEEL ODP
DE
NDE
DE
NDE
6205ZZ
6306ZZ
6308ZZ
6310ZZ
6311ZZ
6212C3
6213
6213C3
6314
6313C3
6317
6313C3
6318
6314C3
6320
6315C3
6324
6205ZZ
6306ZZ
6306ZZ
6309ZZ
6310ZZ
6211C3
6213
6213C3
6213
6213C3
6317
6313C3
6316
6314C3
6318
6315C3
6320
6205ZZ
6206ZZC3
6208ZZC3
6309ZZC3
6311ZZC3
6311ZZC3
6204ZZ
6205ZZC3
6206ZZC3
6208ZZC3
6211ZZC3
6211ZZC3
GLOBAL ODP
DE
NDE
6318
6314C3
6320
6315C3
6315C3
6324
6315C3
6326
6318
6314C3
6318
6315C3
6315C3
6320
6315C3
6322
6326
6322
Factory Modification Reference
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
B - 19
B - 20
Blank
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL:
FLUXMASTER 50 MICRO DRIVE
DESCRIPTION: A compact, low cost AC Drive that is easy to program and
ideal for OEM’s.
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Mixing
• Food Processing
• Fans
• AC Contactor Replacement
• Small Conveyors
• Pumps
FEATURES
• .25 to 1HP, 115V, 50/60Hz Single Phase Input
• .25 to 3HP, 230V, 50/60Hz Single Phase Input
• 2 and 3HP, 230V, 50/60Hz Three Phase Input
• 1 to 3HP, 460V, 50/60Hz Three Phase Input
• 0 to 200Hz Output Frequency Range
• 3 Digit LED Built-In Keypad
• Constant Torque Rated
• Pulse Width Modulation (PWM) Utilizing IGBT Technology
• Selectable Reference Input
• 4 Digital Inputs 2 Are Multifunction
• 1 Analog Output (0-10V)
• 1 Relay Class Digital Output
• 3 V/Hz Control Patterns
• 0 to 999 Seconds Programmable Acceleration and Deceleration Time
• Built-In Brake Transistor on Most Models
• 200% Instantaneous Over Current Capabilities
• 150% Over Current for One Minute
• Motor Overload Protection
• Fault History
• Torque Boost Function
• UL, cUL and CE Approved
Control Products - FLUXMASTER 50
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C-1
LIST PRICES
FLUXMASTER 50
Open Chassis (Panel Mount)
Micro AC Inverter
Simple Programming
Space Saving Design
150% Overload Rating for Demanding Applications
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
115V / 230V / 460V
115V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-1P2-C
0.25
1.4
5.20
2.84
4.65
2
223
FM50-1P5-C
0.5
2.3
5.20
2.84
4.65
2
238
FM50-101-C
1
4.2
5.20
2.84
4.65
2
270
230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-2P2-C
0.25
1.4
5.20
2.84
4.65
2
223
FM50-2P5-OC
0.5
2.3
5.20
2.84
4.65
2
238
FM50-201-OC
1
4.2
5.20
2.84
4.65
2
270
230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-202-C
2
7.5
5.63
4.65
6.77
5
325
FM50-203-C
3
10.5
5.63
4.65
6.77
5
415
460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-401-C
1
2.3
5.63
4.65
6.77
4
350
FM50-402-C
2
3.8
5.63
4.65
6.77
4
385
FM50-403-C
3
5.2
5.63
4.65
6.77
4
440
FLUXMASTER 50 PERIPHERALS
NOTE:
C-2
CATALOGUE NUMBER
DESCRIPTION
LIST PRICE
FM50-DIN-201
Din Rail Kit
15
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - FLUXMASTER 50
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
NEMA 4 &
NEMA 4 WITH OPERATOR DEVICES
MODEL:
FLUXMASTER 50 MICRO DRIVE
NEMA 4 & NEMA 4 with Operator Devices
DESCRIPTION: A compact, low cost AC Drive that is easy to program and
ideal for OEM’s.
FEATURES
Effective 02-11-16
Supercedes All Previous
NEMA 4
NEMA 4 WITH
OPERATOR DEVICES
APPLICATIONS
• Mixing
• Food Processing
• Fans
• Beverage
• Small Conveyors
• Pharmaceutical
FEATURES
NEMA 4 Enclosure (Indoor)
NEMA 4 with Operator Devices (Indoor)
• .5 to 1HP, 115V, 50/60Hz Single Phase Input
• .25 to 3 HP, 230V, 50/60Hz Single Phase Input
• .5 to 3HP, 230V, 50/60Hz Single Phase Input
• 2 and 3 HP, 230V, 50/60Hz Three Phase Input
• 2 and 3HP, 230V, 50/60Hz Three Phase Input
• 1 to 3 HP, 460V, 50/60Hz Three Phase Input
• 1 to 3HP, 460V, 50/60Hz Three Phase Input
• Fully Rated Disconnect Switch
• 0 to 200Hz Output Frequency Range
• Forward - Off - Reverse Selector Switch
• 3 Digit LED Built-In Keypad
• Built-In Potentiometer
• Constant Torque Rated
• 0 to 200 Hz Output Frequency Range
• Pulse Width Modulation (PWM) Utilizing IGBT Technology
• 3 Digit LED Built-In Keypad
• Selectable Reference Input
• Constant Torque Rated
• 4 Digital Inputs 2 Are Multifuction
• Pulse Width Modulation (PWM) Utilizing IGBT Technology
• 1 Analog Output (0-10V)
• Selectable Reference Input
• 1 Relay Class Digital Output
• 4 Digital Inputs 2 Are Multifuction
• 3 V/Hz Control Patterns
• 1 Analog Output (0-10V)
• 0 to 999 Seconds Programmable Acceleration and
Deceleration Time
• 0 to 999 Seconds Programmable Acceleration and
Deceleration Time
• Built-In Brake Transistor on Most Models
• 3 V/Hz Control Patterns
• 200% Instantaneous Over Current Capabilities
• 1 Relay Class Digital Output
• 150% Over Current for One Minute
• Built-In Brake Transistor on Most Models
• Motor Overload Protection
• 200% Instantaneous Over Current Capabilities
• Fault History
• 150% Over Current for One Minute
• Torque Boost Function
• Motor Overload Protection
• UL, cUL and CE Approved
• Fault History
• Torque Boost Function
• UL, cUL and CE approved
Control Products - FLUXMASTER 50 NEMA 4 & NEMA 4 WITH OPERATOR DEVICES
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C-3
NEMA 4
WITH DIGITAL KEYPAD
LIST PRICES
FLUXMASTER 50 NEMA 4 WITH DIGITAL KEYPAD
NEMA 4 (Indoors)
Micro AC Inverter
Simple Programming
150% Overload Rating For Demanding Applications
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
115V / 230V / 460V
115V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-1P5-N4
0.5
2.3
8.49
5.54
6.70
8
428
FM50-101-N4
1
4.2
8.49
5.54
6.70
8
455
230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-2P5-N4
0.5
2.3
8.49
5.54
6.70
8
435
FM50-201-N4
1
4.2
8.49
5.54
6.70
8
475
230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-202-N4
2
7.5
11.62
9.14
7.11
14
655
FM50-203-N4
3
10.5
11.62
9.14
7.11
14
730
460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT
NOTE:
C-4
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-401-N4
1
2.3
11.62
9.14
7.11
13
713
FM50-402-N4
2
3.8
11.62
9.14
7.11
14
795
FM50-403-N4
3
5.2
11.62
9.14
7.11
14
880
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - FLUXMASTER 50 NEMA 4 WITH DIGITAL KEYPAD
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
NEMA 4
WITH OPERATOR DEVICES
LIST PRICES
FLUXMASTER 50 NEMA 4 WITH OPERATOR DEVICES
NEMA 4 (Indoors)
Micro AC Inverter
Simple Programming
150% Overload Rating For Demanding Applications
Digital Keypad
Disconnect Switch, Speed Potentiometer and
Forward - Off - Reverse Selector Switch
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V / 460V
230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-2P2-N4FS
0.25
1.4
8.49
5.54
7.19
8
538
FM50-2P5-N4FS
0.5
2.3
8.49
5.54
7.19
8
550
FM50-201-N4FS
1
4.2
8.49
5.54
7.19
8
575
230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
FM50-202-N4FS
2
7.5
11.62
9.14
8.33
14
750
FM50-203-N4FS
3
10.5
11.62
9.14
8.33
14
840
APPROX. WT.
LBS
LIST
PRICE
460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT
NOTE:
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
DIMENSIONS
HEIGHT
WIDTH
DEPTH
FM50-401-N4FS
1
2.3
11.62
9.14
8.33
13
838
FM50-402-N4FS
2
3.8
11.62
9.14
8.33
14
903
FM50-403-N4FS
3
5.2
11.62
9.14
8.33
14
1,003
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - FLUXMASTER 50 NEMA 4 WITH OPERATOR DEVICE
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C-5
FEATURES
MODEL:
L510 MEDIUM DUTY MICRO DRIVE
DESCRIPTION: A compact, low cost and versatile AC Drive that is easy to
program and ideal for OEM’s.
APPLICATIONS
• Mixing
• AC Contactor Replacement
• Fans
• Pumps
• Small Conveyors
FEATURES
• Chassis Style Enclosure (IP 20)
• Sensorless Vector or V/Hz with Auto Torque Boost Feature
• 0.25 to 1HP, 115V, 50/60Hz, 1-Phase
• 0.25 to 3HP, 230V, 50/60Hz, 1-Phase
• 0.5 to 3HP, 230V, 50/60Hz, 3-Phase
• 1 to 3 HP, 460V, 50/60Hz, 3-Phase
• Extensive Diagnostic and Monitoring Capabilities
• Micro Drive with Din Rail Option
• PID Control
• 0 to 200Hz Speed Range
• 24VDC, 50mA External Sensor Supply Built-in
• 8 Preset Speeds
• Multi-function Analog Input/Output
• Built-in RS485 Modbus
• RJ45 Interface for PC and Copy Module
• cUL and CE Approved
C-6
Control Products - L510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
Effective 02-11-16
Supercedes All Previous
LIST PRICES
L510 MICRO DRIVE
Open Chassis
Micro AC Inverter
V/Hz and Sensorless Vector
PID Control
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
115V / 230V / 460V
115V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
CATALOGUE NUMBER
CONSTANT
TORQUE
HP
CONSTANT
TORQUE
AMPS
DIMENSIONS
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
L510-1P2-H1-U
.25
1.8
5.55
2.83
5.48
2
309
L510-1P5-H1-U
.50
2.6
5.55
2.83
5.48
2
317
L510-101-H1-U
1
4.3
5.67
4.65
5.80
3.5
342
230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT
CATALOGUE NUMBER
CONSTANT
TORQUE
HP
CONSTANT
TORQUE
AMPS
DIMENSIONS
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
L510-2P2-H1-U
.25
1.8
5.55
2.83
5.48
2
291
L510-2P5-H1-U
.50
2.6
5.55
2.83
5.48
2
306
L510-201-H1-U
1
4.3
5.55
2.83
5.48
2
313
L510-202-H1-U
2
7.5
5.67
4.65
5.80
3.5
430
L510-203-H1-U
3
10.5
5.67
4.65
5.80
3.5
515
230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT
CATALOGUE NUMBER
CONSTANT
TORQUE
HP
CONSTANT
TORQUE
AMPS
DIMENSIONS
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
L510-2P5-H3-U
.50
2.6
5.55
2.83
5.48
2
306
L510-201-H3-U
1
4.3
5.55
2.83
5.48
2
313
L510-202-H3-U
2
7.5
5.67
4.65
5.80
3.5
423
L510-203-H3-U
3
10.5
5.67
4.65
5.80
3.5
471
460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT
NOTE:
CATALOGUE NUMBER
CONSTANT
TORQUE
HP
CONSTANT
TORQUE
AMPS
DIMENSIONS
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
L510-401-H3-U
1
2.3
5.67
4.65
5.80
3.5
434
L510-402-H3-U
2
3.8
5.67
4.65
5.80
3.5
478
L510-403-H3-U
3
5.2
5.67
4.65
5.80
3.5
577
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - L510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C-7
N3
MODEL:
FEATURES
N3 COMPACT DRIVE
DESCRIPTION: A compact, low cost and versatile AC Drive that can
operate in constant torque, variable torque. V/Hz and
sensorless vector modes for maximum application flexibilty.
APPLICATIONS
• Fan and Pump Systems
• Centrifugal Applications
• Conveyors
• OEM Products
• Mixers
FEATURES
• 1 to 40HP, 230V, 50/60Hz Three Phase Input
• 1 to 75HP, 460V, 50/60Hz Three Phase Input
• 0 to 400Hz Output Frequency Range
• 4 Digit LED Built-In Keypad
• Constant Torque Rated
• Pulse Width Modulation (PWM) Utilizing IGBT Technology
• Programmable Reference Input
• 6 Digital Inputs
• 1 Analog Output
• 3 Programmable Digital Outputs
• 0 to 3600 Seconds Programmable Acceleration and Deceleration Time
• Built-In Brake Transistor Up to 20 HP
• 150% Over Current for One Minute
• Motor Overload Protection
• Fault History
• Operation Time
• Torque Boost Parameter
• PID Control with Sleep and Wakeup Mode
• Sensorless Vector or V/Hz Mode
• 8 Preset Speed Setting
• Communication Cards Available RS-485, RS-232
• Setup Software
• Options: Copy Unit
• Programming: Basic and Advanced
• 8 LED Lights for Operator Indication
• Autotuning Function
• “S” Curves for Acceleration and Deceleration
• DC Injection Braking
• Skip Frequencies
• 8 Step Programmable Acceleration and Deceleration
• 2 Programmable/Select Acceleration and Deceleration Ramps
• Built-In BACnet IP
• cUL and CE Approved
C-8
Control Products - N3
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
Effective 02-11-16
Supercedes All Previous
N3 NEMA 1
LIST PRICES
N3 NEMA 1
Compact AC Inverter
V/Hz and Sensorless Vector
PID Control with Sleep and Wakeup Mode
“S” Curves for Accel and Decel
Parameter Copy Unit Available
N3-Link Configuration Software
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V
230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT
NOTE:
DIMENSIONS (APPROX.)
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
N3-201-C
1
4.5
6.42
3.54
5.79
3
388
N3-202-C
2
7.5
6.42
3.54
5.79
3
465
N3-203-C
3
10.5
7.36
5.04
5.83
4
625
N3-205-C
5
17.5
7.36
5.04
5.83
5
703
N3-207-C
7.5
26
10.24
7.32
7.68
13
1,043
N3-210-C
10
35
10.24
7.32
7.68
13
1,180
N3-215-N1
15
48
14.20
10.43
9.74
27
1,778
N3-220-N1
20
64
14.20
10.43
9.74
27
2,020
N3-225-N1
25
80
14.20
10.43
9.74
29
2,675
N3-230-N1
30
96
25.50
10.73
12.00
67
3,610
N3-240-N1
40
130
25.50
10.73
12.00
67
4,788
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - N3 NEMA 1
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C-9
N3 NEMA 1 & PERIPHERALS
LIST PRICES
N3 NEMA 1 & PERIPHERALS
Compact AC Inverter
V/Hz and Sensorless Vector
PID Control with Sleep and Wakeup Mode
“S” Curves for Accel and Decel
Parameter Copy Unit Available
N3-Link Configuration Software
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
460V
460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT
DIMENSIONS (APPROX.)
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
N3-401-C
1
2.3
6.42
3.54
5.79
3
455
N3-402-C
2
3.8
6.42
3.54
5.79
3
518
N3-403-C
3
5.2
7.38
5.04
5.83
4
665
N3-405-C
5
8.8
7.38
5.04
5.83
4
768
N3-407-C
7.5
13
10.24
7.32
7.68
13
1,093
N3-410-C
10
17.5
10.24
7.32
7.68
13
1,180
N3-415-C
15
25
10.24
7.32
7.68
13
1,403
N3-420-N1
20
32
14.20
10.43
9.74
27
2,075
N3-425-N1
25
40
14.20
10.43
9.74
29
2,600
N3-430-N1
30
48
14.20
10.43
9.74
29
2,900
N3-440-N1
40
64
25.50
10.73
12.00
67
3,813
N3-450-N1
50
80
25.50
10.73
12.00
67
4,675
N3-460-N1
60
96
29.60
12.30
15.20
102
5,350
N3-475-N1
75
128
29.60
12.30
15.20
102
6,135
N3 PERIPHERALS
CATALOGUE NUMBER
DESCRIPTION
LIST PRICE
SIF-485
COMMUNICATIONS INTERFACE RS485
54
SIF-232
RS232 INTERFACE CARD WITH CABLE TO PC
45
SIF-MP
MEMORY PAK
27
SW3001
REMOTE WIRE FOR KEYPAD (1.0M)
94
SW3002
REMOTE WIRE FOR KEYPAD (2.0M)
98
SW3003
REMOTE WIRE FOR KEYPAD (3.0M)
103
SNA201
NEMA 1 BOX FOR FRAME 1***
27
SNA202
NEMA 1 BOX FOR FRAME 2***
29
SNA203
NEMA 1 BOX FOR FRAME 3***
38
*** FRAME 1
*** FRAME 2
*** FRAME 3
NOTE:
C - 10
201-C, 202-C, 401-C, 402-C
203-C, 205-C, 403-C, 405-C
207-C, 210-C, 407-C, 410-C, 415-C
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - N3 NEMA 1 & PERIPHERALS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
FEATURES
MODEL:
F510 FAN AND PUMP DRIVE
Effective 02-11-16
Supercedes All Previous
DESCRIPTION: A versatile AC Drive that is easily configured and handles
almost any fan, blower or centrifugal pump application.
APPLICATIONS
• Fans
• Centrifugal Pumps
• Blowers
• HVAC Industries
• Water and Wastewater Industries
• Irrigation
FEATURES
• Control Modes for V/F, Sensorless Vector
• Application Macros for Quick Start-up. Macros Available for: Fans, Pumps, HVAC
• Built-in PLC as Standard
• LCD Keypad
• PID Control with advanced diagnostics and sleep mode
• 5 to 150HP (Variable Torque), 230V, 50/60Hz, 3-Phase
• 5 to 250HP (Variable Torque), 460V, 50/60Hz, 3-Phase
• Conformal Coating on PC Boards
• Diagnostics Registers for Troubleshooting
• Flexible Input/ Output Configurations that Incorporate Normally Open or Normally Closed Signals
• 0 to 400Hz Speed Range
• Built-in RS485 Communications (Modbus, BACNet and Metasys are Standard Protocols)
• Enhanced Design for Smoother and Quieter Motor Operation
• Pulse Output and Pulse Follower
• PTC Input Available for Direct Thermal Protection of the Motor
• Thermal Management on the Heat Sink for Overtemperature Fault Avoidance
• Select Between Closed Loop Speed and Torque Control in Vector Mode
• Built-in Brake Transistor on Models F510-2005-C3 thru F510-2030-C3 also F510-4005-C3 thru F510-4040-C3
• Built-in DC Link Reactor on Models F510-2060-C3 thru F510-2150-C3 also F510-4100-C3 thru F510-4250-C3
• cUL and CE Approved
Control Products - F510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 11
LIST PRICES
F510 FAN & PUMP
A versatile AC Drive that is easily configured
and handles almost any fan, blower or
centrifugal pump application.
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V / 460V
230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT
CATALOGUE NUMBER
HP
VARIABLE TORQUE
DRIVE AMPS
F510-2005-C3-U
5
F510-2008-C3-U
DIMENSIONS
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
14.5
12.4
5.51
6.97
8.4
934
7.5
21.0
12.4
5.51
6.97
8.4
952
F510-2010-C3-U
10
30.0
11.81
8.27
8.46
13.6
1,353
F510-2015-C3-U
15
40.0
11.81
8.27
8.46
13.6
1,500
F510-2020-C3-U
20
56.0
14.17
10.43
8.86
22.0
1,882
F510-2025-C3-U
25
69.0
14.17
10.43
8.86
22.0
2,352
F510-2030-C3-U
30
79.0
14.17
10.43
8.86
22.0
2,786
F510-2040-C3-U
40
110.0
20.67
11.18
9.92
66.1
4,116
F510-2050-C3-U
50
138.0
20.67
11.18
9.92
66.1
4,822
F510-2060-C3-U*
60
169.0
22.83
13.54
11.81
89.3
6,865
F510-2075-C3-U*
75
200.0
22.83
13.54
11.81
89.3
7,542
F510-2100-C3-U*
100
250.0
31.10
18.08
12.78
162.8
9,879
F510-2125-C3-U*
125
312.0
31.10
18.08
12.78
162.8
12,348
F510-2150-C3-U*
150
400.0
39.37
27.16
16.14
405
24,696
460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT
CATALOGUE NUMBER
HP
VARIABLE TORQUE
DRIVE AMPS
F510-4005-C3-U
5
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
9.2
12.4
5.51
6.97
8.8
912
F510-4008-C3-U
7.5
11.1
12.4
5.51
6.97
8.8
1,004
F510-4010-C3-U
10
17.5
12.4
5.51
6.97
8.8
1,470
F510-4015-C3-U
15
23.0
11.81
8.27
8.46
13.6
1,529
F510-4020-C3-U
20
31.0
11.81
8.29
8.46
13.6
2,018
F510-4025-C3-U
25
38.0
14.17
10.43
8.86
22
2,375
F510-4030-C3-U
30
44.0
14.17
10.43
8.86
22
2,952
F510-4040-C3-U
40
58.0
14.17
10.43
8.86
22
3,176
F510-4050-C3-U
50
72.0
20.67
11.18
9.92
66.1
4,050
F510-4060-C3-U
60
88.0
20.67
11.18
9.92
66.1
5,057
F510-4075-C3-U
75
103.0
20.67
11.18
9.92
66.1
5,557
F510-4100-C3-U*
100
145.0
22.83
13.70
11.81
89.3
6,575
F510-4125-C3-U*
125
165.0
22.83
13.70
11.81
89.3
9,996
F510-4150-C3-U*
150
208.0
31.10
18.08
12.78
163.1
12,584
F510-4215-C3-U*
200
250.0
31.10
18.08
12.78
163.1
14,348
F510-4250-C3-U*
250
328.0
31.10
18.08
12.78
163.1
20,996
* Models Are Open Chassis, NEMA 1 Kits Available.
NOTE:
C - 12
DIMENSIONS
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - F510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PERIPHERALS
F510 FAN & PUMP PERIPHERALS
A versatile AC Drive that is easily configured
and handles almost any fan, blower or
centrifugal pump application.
Effective 02-11-16
Supercedes All Previous
F510 PERIPHERALS
CATALOGUE NUMBER
NOTE:
DESCRIPTION
LIST PRICE
JN5-CB-01M
EXTENSION WIRE (1M)
38
JN5-CB-02M
EXTENSION WIRE (2M)
50
JN5-CB-03M
EXTENSION WIRE (3M)
75
JN5-CB-05M
EXTENSION WIRE (5M)
100
JN5-CM-USB
USB CABLE TO CONNECT TO A PC
125
JN5-CU
COPY UNIT
190
JN5-NK-A06
F510 FRAME 6 NEMA 1 KIT (F510-2060-C3 AND A510-2075-C3), (A510-4100-C3 AND A510-4125-C3)
690
JN5-NK-A07
F510 FRAME 7 NEMA 1 KIT (A510-2100-C3 AND A510-2125-C3), (A510-4150-C3 TO A510-4250-C3)
940
JN5-NK-A08
F510 FRAME 8 NEMA 1 KIT (A510-2150-C3)
1,000
JN5-OP-F02
LCD OPERATOR
190
JN5-OP-F03
IP 20 LCD HOA OPERATOR
100
JN5-OP-A03
BLANK OPERATOR
100
JN5-CM-PDP
PROFIBUS COMMUNICATION INTERFACE MODULE (GATEWAY EXTERNAL)
500
JN5-CM-DNET
DEVICENET CARD (GATEWAY EXTERNAL)
300
JN5-CM-CAN
CANOPAN CARD (GATEWAY EXTERNAL)
300
JN5-IO-8DO
1 TO 8 DIGITAL OUTPUT CARD
225
JNEP-16-F
REMOTE ANALOG OPERATOR
170
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - F510 PERIPHERALS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 13
FEATURES
MODEL:
A510 HEAVY DUTY AC DRIVE
DESCRIPTION: A versatile AC Drive that can control todays demanding
motor driven applications. This highly flexible drive has
multiple control modes and a built-in PLC.
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Mixing
• Machine Tools
• Pumps (Centrifugal, Positive Displacement, Metering, etc.)
• Conveyors
• Fans
• Extrusion and Injection Molding
• Packaging Machines
• Compressors
• Winders / Unwinders
• Crushers / Grinders
• Crane / Hoist / Elevator
FEATURES
• Control Modes for V/F, V/F with PG Feedback, Sensorless Vector, and Closed Loop Vector
• Simple PLC Function Built-in
• Advanced Regenerative Load Handling Capability
• 1 to 100HP (CT), 230V, 50/60Hz, 3-Phase
• 1 to 150HP (CT), 460V, 50/60Hz, 3-Phase
• 1 to 200HP (CT) 575V, 50/60Hz, 3-Phase
• 15 to 250HP (CT) 690V, 50/60Hz, 3-Phase
• Conformal Coating on PC Boards
• LCD Keypad That is Remotely Mountable
• Flexible Input/Output Configurations That Accept Normally Open or Normally Closed Signals
• 0 to 400Hz Speed Range (0-1200Hz selectable)
• PID Control
• Diagnostics Registers for Troubleshooting
• Built-in RS485 Communications (Modbus)
• Enhanced Design for Smother and Quieter Motor Operation
• Pulse Output and Pulse Follower
• Select Between Closed Loop Speed and Torque Control in Vector Mode
• Built-in Brake Transistor on Models (A510-2001-C thru A510-2025-C3), (A510-4001-C3 thru A510-4030-C3) and (A510-5001-C3
thru A510-6030-C3)
• Built-in DC Link Reactor on Models (A510-2050-C3 thru A510-2100-C3), (A510-4075-C3 thru A510-4215-C3) and (A510-6075-C3
thru A510-6250-C3)
• cUL and CE Approved
C - 14
Control Products - A510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
A510 HEAVY DUTY AC DRIVE
A versatile AC Drive that can control todays demanding
motor driven applications. This highly flexible drive has
multiple control modes and a built-in PLC.
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V
230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
A510-2001-C-U
1
5.0
9.61
5.12
5.91
6
687
A510-2002-C-U
2
8.0
9.61
5.12
5.91
6
720
A510-2003-C-U
3
11.0
12.40
5.51
6.97
9
886
LIST
PRICE
230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT
DIMENSIONS
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
A510-2005-C3-U
5
17.5
12.40
5.51
6.97
9
930
A510-2008-C3-U
7.5
25.0
12.40
5.51
6.97
9
1,351
A510-2010-C3-U
10
33.0
11.80
8.27
8.46
14
1,462
A510-2015-C3-U
15
47.0
14.20
10.43
8.86
22
1,937
CATALOGUE NUMBER
A510-2020-C3-U
20
60.0
14.20
10.43
8.86
22
2,269
A510-2025-C3-U
25
73.0
14.20
10.43
8.86
22
2,801
A510-2030-C3-U
30
85.0
20.70
11.20
9.92
67
4,328
A510-2040-C3-U
40
115.0
20.70
11.20
9.92
67
5,424
A510-2050-C3-U*
50
145.0
22.80
13.54
11.81
90
6,863
A510-2060-C3-U*
60
180.0
22.80
13.54
11.81
90
8,025
A510-2075-C3-U*
75
215.0
31.10
18.10
12.80
163
9,741
A510-2100-C3-U*
100
283.0
31.10
18.10
12.80
163
12,176
* Models Are Open Chassis, NEMA 1 Kits Available.
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - A510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 15
LIST PRICES
A510 HEAVY DUTY AC DRIVE
A versatile AC Drive that can control todays demanding
motor driven applications. This highly flexible drive has
multiple control modes and a built-in PLC.
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
460V
460V 3-PHASE
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
A510-4001-C3-U
1
3.4
9.61
5.12
5.91
6
709
A510-4002-C3-U
2
4.2
9.61
5.12
5.91
6
742
A510-4003-C3-U
3
5.5
9.61
5.12
5.91
6
897
A510-4005-C3-U
5
9.2
12.40
5.51
6.97
9
997
A510-4008-C3-U
7.5
14.8
12.40
5.51
6.97
9
1,450
A510-4010-C3-U
10
18.0
11.80
8.27
8.46
14
1,556
A510-4015-C3-U
15
24.0
11.80
8.27
8.46
14
1,993
A510-4020-C3-U
20
31.0
11.80
8.27
8.46
14
2,380
A510-4025-C3-U
25
39.0
14.20
10.43
8.86
22
2,967
A510-4030-C3-U
30
45.0
14.20
10.43
8.86
22
3,155
A510-4040-C3-U
40
60.0
20.70
11.20
9.92
67
4,184
A510-4050-C3-U
50
75.0
20.70
11.20
9.92
67
5,048
A510-4060-C3-U
60
91.0
20.70
11.20
9.92
67
5,756
A510-4075-C3-U
75
118.0
20.70
11.20
9.92
67
6,309
A510-4100-C3-U*
100
150.0
22.80
13.70
11.81
90
9,851
A510-4125-C3-U*
125
180.0
22.80
13.70
11.81
90
12,508
A510-4150-C3-U*
150
216.0
31.10
18.10
12.80
164
14,500
A510-4215-C3-U*
200
295.0
31.10
18.10
12.80
164
19,038
* Models Are Open Chassis, NEMA 1 Kits Available.
NOTE:
C - 16
DIMENSIONS
CATALOGUE NUMBER
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - A510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
A510 HEAVY DUTY AC DRIVE
A versatile AC Drive that can control todays demanding
motor driven applications. This highly flexible drive has
multiple control modes and a built-in PLC.
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
575V
575V 3-PHASE INPUT / 575V 3-PHASE OUTPUT
DIMENSIONS
CATALOGUE NUMBER
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
A510-5001-C3-U
1
1.7
12.4
5.51
7.0
8.8
1,084
A510-5002-C3-U
2
3
12.4
5.51
7.0
8.8
1,176
A510-5003-C3-U
3
4.2
12.4
5.51
7.0
8.8
1,250
A510-5005-C3-U
5
6.6
11.9
8.30
8.5
13.6
1,323
A510-5008-C3-U
7.5
9.9
11.9
8.30
8.5
13.6
1,397
A510-5010-C3-U
10
11.4
11.9
8.30
8.5
13.6
1,470
A510-6020-C3-U
15
19
14.2
10.50
8.9
22.0
2,389
A510-6025-C3-U
20
22
14.2
10.50
8.9
22.0
3,069
A510-6030-C3-U
25
27
14.2
10.50
8.9
22.0
3,198
A510-6040-C3-U
30
34
20.7
11.20
10.0
66.1
4,043
A510-6050-C3-U
40
42
20.7
11.20
10.0
66.1
4,962
A510-6060-C3-U
50
54
20.7
11.20
10.0
66.1
6,064
A510-6075-C3-U*
60
62
22.9
13.60
11.9
89.1
6,799
A510-6100-C3-U*
75
86
22.9
13.60
11.9
89.1
8,574
A510-6125-C3-U*
100
99
22.9
13.60
11.9
89.1
11,907
A510-6150-C3-U*
125
131
22.9
13.60
11.9
89.1
13,690
A510-6215-C3-U*
150
163
31.2
18.10
12.8
162.8
19,295
A510-6250-C3-U*
200
192
31.2
18.10
12.8
162.8
21,500
* Models Are Open Chassis, NEMA 1 Kits Available.
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - A510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 17
LIST PRICES
A510 HEAVY DUTY AC DRIVE
A versatile AC Drive that can control todays demanding
motor driven applications. This highly flexible drive has
multiple control modes and a built-in PLC.
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
690V
690V 3-PHASE INPUT / 690V 3-PHASE OUTPUT
HP
CONSTANT TORQUE
DRIVE AMPS
CONSTANT TORQUE
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
A510-6015-C3-U
15
15
14.2
10.5
8.9
22
2,132
A510-6020-C3-U
20
19
14.2
10.5
8.9
22
2,389
A510-6025-C3-U
25
22
14.2
10.5
8.9
22
3,069
A510-6030-C3-U
30
27
14.2
10.5
8.9
22
3,198
A510-6040-C3-U
40
34
20.7
11.2
10.0
66.1
4,043
A510-6050-C3-U
50
42
20.7
11.2
10.0
66.1
4,962
A510-6060-C3-U
60
54
20.7
11.2
10.0
66.1
6,064
A510-6075-C3-U*
75
62
22.9
13.6
11.9
89.1
6,799
A510-6100-C3-U*
100
86
22.9
13.6
11.9
89.1
8,574
A510-6125-C3-U*
125
99
22.9
13.6
11.9
89.1
11,907
A510-6150-C3-U*
150
131
22.9
13.6
11.9
89.1
13,690
A510-6215-C3-U*
200
163
31.2
18.1
12.8
162.8
19,295
A510-6250-C3-U*
250
192
31.2
18.1
12.8
162.8
21,500
* Models Are Open Chassis, NEMA 1 Kits Available.
NOTE:
C - 18
DIMENSIONS
CATALOGUE NUMBER
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - A510
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
LIST PRICES
PERIPHERALS
A510 HEAVY DUTY AC DRIVE PERIPHERALS
A versatile AC Drive that can control todays demanding
motor driven applications. This highly flexible drive has
multiple control modes and a built-in PLC.
Effective 02-11-16
Supercedes All Previous
A510 PERIPHERALS
CATALOGUE NUMBER
NOTE:
DESCRIPTION
LIST PRICE
JN5-CB-01M
EXTENSION WIRE (1M)
38
JN5-CB-02M
EXTENSION WIRE (2M)
50
JN5-CB-03M
EXTENSION WIRE (3M)
75
JN5-CB-05M
EXTENSION WIRE (5M)
100
JN5-CM-USB
USB CABLE TO CONNECT TO A PC
125
JN5-CU
COPY UNIT
190
JN5-NK-A06
A510 FRAME 6 NEMA 1 KIT (A510-2050-C3 AND A510-2060-C3), (A510-4075-C3 AND A510-4100-C3),
(A510-6075-C3 TO A510-6125-C3)
690
JN5-NK-A07
A510 FRAME 7 NEMA 1 KIT (A510-2075-C3 AND A510-2100-C3), (A510-4125-C3 TO A510-4215-C3),
(A510-6150-C3 TO A510-6250-C3)
940
JN5-OP-A02
LCD OPERATOR
190
JN5-OP-A03
BLANK OPERATOR
100
JN5-PG-L
LINE DRIVER SPEED FEEDBACK CARD
190
JN5-PG-O
OPEN COLLECTOR SPEED FEEDBACK CARD
250
JN5-PG-PM
SYNCHRONOUS MOTOR LINE DRIVER SPEED FEEDBACK CARD
190
JN5-CM-PDP
PROFIBUS COMMUNICATION INTERFACE MODULE (GATEWAY EXTERNAL)
500
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - A510 PERIPHERALS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 19
SP2000
FEATURES
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Mixing
• Fans
• Pumps (Centrifugal, Positive Displacement, Metering etc.)
• Conveyors
• Crushers
• Mechanical Drive Upgrade / Replacement
• Process Lines
• Hammer Mill, Ball Mill
FEATURES
• Power Range; 5HP to 4000HP
• Wide Power Supply Voltage Range; 230-690Vac, 50/60Hz, 3-Phase
• Enclosure, IP00, IP20
• V/Hz, Sensorless Vector, Closed Loop Vector and Regenerative
• Complete Communications Offering
• 200% Torque Available
• 0-1000 Hz Speed Range
• 5 Languages; English, Italian, Spanish, Portuguese, German
• Start-Up Wizard Included
• Carrier Frequency 2.0 to 16Khz
• 4 Integrated Multi-Function Programmable Logic Blocks
• Programming and Monitoring Software Available
• 4 Separate Acceleration / Deceleration Ramps
• 3 Separate Analog Inputs
• 15 Multi-speed Setting
• PID with Sleep and Wake modes
• 3 Analog Outputs
• Built-In Timer Function
• Programmable Digital Outputs
• 3 Separate Motor Configurations
• 8 Digital Inputs
• Built-In Brake Chopper on Many Models
• 4 Line Display with 11 LED Indicators
• Fault History Log
• Keypad Copy Module
• Auto Tune Function
• S Curve Selection for Acceleration and Deceleration
• Skip Frequencies
• 3-Year Warranty
• cUL, CE, Gost, C-Tick Approved
C - 20
Control Products - SP2000
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
SP2000
SP2000 - OVERLOAD SELECTION CHART
SP2000 - OVERLOAD SELECTION CHART
APPLICATIONS
OVERLOAD
LGT
Agitator
STD
HVY
STG
X
Atomizer
X
Bottle Washer
X
APPLICATIONS
OVERLOAD
LGT
STD
Hydraulic Power Jack (Inj. Mould Machines)
Extruders
HVY
STG
X
X
X
Grinder
X
Centrifuge
X
Hydraulic Power Pack
X
Chipper
X
Mill
X
Ball Mill
X
Piston Compressor Loaded
X
Piston Compressor Unloaded
X
Hammer Mill
X
Screw Compressor Loaded
X
Roller Mill
X
Screw Compressor Unloaded
X
Conveyor Belt
Conveyor Roller
Mixer
X
X
Palletiser
X
X
Bore Pumps
X
Conveyor Screw
Crusher (Cone)
Planer
X
Crusher (Jaw)
Centrifugal Pumps
X
X
X
X
Positive Displacement Pumps
X
Crusher (Rotary)
X
Slurry Pumps
Crusher (Vertical Impact)
X
Pulper
Debarker
X
Rotary Table
X
Dryer
X
Sander
X
Dust Collector
X
X
Edger
X
X
X
X
Bandsaw
X
Circular Saw
X
X
Damped Axial Fan
X
Separator
Undamped Axial Fan
X
Vibrating Screen
X
Centrifugal Damped Fan
X
Shredder
X
Undamped Centrifugal Fan
X
Slicer
X
High Pressure Fan
X
Tumbler
X
Spinner
X
X
Elevators
X
Hoists & Cranes
X
X
Industrial Washers
Screw Injection Moulding Machines
X
X
Looms
X
Mechanical Presses
X
X
Axe Control
X
Drills
X
Mills
Forming Machines
X
X
Shears
X
X
X
X
Winding / Unwinding Machines
X
X
X
Drawplates
X
X
Control Products - SP2000 - OVERLOAD SELECTION CHART
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 21
SP2000 SINUS PENTA
LIST PRICES
SP2000 - SINUS PENTA
3 Year Warranty
Flexible I/O
Heat Sink Segregation
Conformal Coating on all boards
Full Metal Casing
Wide Range of Communication Modules
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
480V
480V 3-PHASE IP20/IP00
OVERLOAD CAPACITY
FRAME
SIZE
CATALOGUE NUMBER
HP
LIGHT
120%
HP
STANDARD
140%
HP
HEAVY
175%
HP
STRONG
200%
I-NOM
DIMENSIONS
(APPROX.)
I-MAX
HEIGHT WIDTH
APPROX.
WT. LBS
LIST
PRICE
DEPTH
S05
S05
S05
SP2000-0005-4T-BIK2
SP2000-0007-4T-BIK2
SP2000-0014-4T-BIK2
7.5
10
12.5
6
7.5
12.5
5
6
12.5
4
5
10
10.5
12.5
16.5
11.5
13.5
25
13.5
13.5
13.5
7
7
7
7
7
7
16
16
16
2,381
2,446
2,748
S12
S12
S12
S12
S12
SP2000-0016-4T-BIK2
SP2000-0020-4T-BIK2
SP2000-0025-4T-BIK2
SP2000-0030-4T-BIK2
SP2000-0036-4T-BIK2
20
25
30
30
50
15
20
25
30
40
15
20
25
30
40
12.5
15
20
25
35
27
30
41
41
60
30
36
48
56
72
16
16
16
16
16
8.5
8.5
8.5
8.5
8.5
9
9
9
9
9
28
28
28
28
28
3,038
3,241
3,683
3,819
4,498
S15
S15
SP2000-0040-4T-BIK2
SP2000-0049-4T-BIK2
60
65
50
60
40
50
35
40
72
80
80
96
18.5
18.5
9
9
13
13
50
50
5,402
5,874
S20
S20
S20
S20
SP2000-0060-4T-BIK2
SP2000-0067-4T-BIK2
SP2000-0074-4T-BIK2
SP2000-0086-4T-BIK2
75
90
100
125
75
90
95
100
60
70
75
90
50
55
60
75
88
103
120
135
112
118
144
155
24
24
24
24
11
11
11
11
13
13
13
13
80
80
80
80
6,674
7,100
7,786
8,435
S30
S30
S30
S30
SP2000-0113-4T-BIK2
SP2000-0129-4T-BIK2
SP2000-0150-4T-BIK2
SP2000-0162-4T-BIK2
150
170
180
200
125
150
180
200
100
125
150
180
88
100
125
150
180
195
215
240
200
215
270
290
29.5
29.5
29.5
29.5
12
12
12
12
16.5
16.5
16.5
16.5
112
112
112
112
11,783
14,569
14,569
14,847
S41
S41
S41
S41
SP2000-0180-4T-XIK0
SP2000-0202-4T-XIK0
SP2000-0217-4T-XIK0
SP2000-0260-4T-XIK0
270
300
340
380
250
300
340
380
220
250
300
350
165
200
220
270
300
345
375
425
340
420
460
560
35
35
35
35
20
20
20
20
16
16
16
16
267
267
267
267
20,171
21,299
23,230
24,374
*S51
*S51
*S51
SP2000-0313-4T-XIK0
SP2000-0367-4T-XIK0
SP2000-0402-4T-XIK0
430
570
610
430
510
610
350
430
550
300
340
430
480
550
680
600
680
850
35
35
35
23
23
23
16
16
16
311
311
311
29,409
33,517
35,284
*S60
*S60
SP2000-0457-4T-XIK0
SP2000-0524-4T-XIK0
610
680
610
680
510
610
450
510
720
800
880
960
52
52
35
35
21
21
573
573
55,999
58,953
*S65
*S65
*S65
SP2000-0598-4T-XIK0
SP2000-0748-4T-XIK0
SP2000-0831-4T-XIK0
760
860
1090
760
860
1090
680
760
860
550
680
760
900
1000
1200
1100
1300
1440
55
55
55
39
39
39
22
22
22
970
970
970
92,644
101,414
110,167
* Input and Output choke is required for these models.
I-NOM:
I-MAX:
Continuous rated current of the inverter
Maximum current produced by the inverter for 120 seconds every 20 minutes up to S30 and 60 seconds every 10 minutes for S41 and larger
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
C - 22
Control Products - SP2000
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
SP2000 SINUS PENTA
LIST PRICES
SP2000 - SINUS PENTA
3 Year Warranty
Flexible I/O
Heat Sink Segregation
Conformal Coating on all boards
Full Metal Casing
Wide Range of Communication Modules
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
575V
575V 3-PHASE IP20/IP00
OVERLOAD CAPACITY
FRAME
SIZE
CATALOGUE NUMBER
HP
LIGHT
120%
HP
STANDARD
140%
HP
HEAVY
175%
HP
STRONG
200%
I-NOM
DIMENSIONS
(APPROX.)
I-MAX
HEIGHT WIDTH
APPROX.
WT. LBS
LIST
PRICE
DEPTH
S12
S12
S12
S12
S12
SP2000-0003-5T-XA2K2
SP2000-0004-5T-XA2K2
SP2000-0006-5T-XA2K2
SP2000-0012-5T-XA2K2
SP2000-0018-5T-XA2K2
5.5
7.5
10
12.5
15
5.5
7.5
10
10
15
4
5.5
7.5
10
12.5
4
5.5
5.5
7.5
10
7
9
11
13
17
8.5
11
13.5
16
21
16
16
16
16
16
8.5
8.5
8.5
8.5
8.5
9
9
9
9
9
23
23
23
23
23
2,850
2,978
3,220
3,386
3,506
S14
S14
S14
S14
S14
SP2000-0019-5T-BA2K2
SP2000-0021-5T-BA2K2
SP2000-0022-5T-BA2K2
SP2000-0024-5T-BA2K2
SP2000-0032-5T-BA2K2
20
25
30
40
50
15
20
30
35
50
15
20
25
30
40
12.5
15
20
25
35
21
25
33
40
52
25
30
40
48
63
21
21
21
21
21
11
11
11
11
11
10
10
10
10
10
41
41
41
41
41
5,265
5,544
5,855
5,991
6,901
S22
S22
S22
S22
SP2000-0042-5T-BA2K2
SP2000-0051-5T-BA2K2
SP2000-0062-5T-BA2K2
SP2000-0069-5T-BA2K2
60
75
90
125
60
75
90
100
50
60
75
75
40
50
60
60
60
80
85
105
72
96
110
135
33
33
33
33
11
11
11
11
14
14
14
14
119
119
119
119
10,815
11,510
13,198
14,113
S32
S32
S32
S32
SP2000-0076-5T-BA2K2
SP2000-0088-5T-BA2K2
SP2000-0131-5T-BA2K2
SP2000-0164-5T-BA2K2
125
150
180
220
125
150
180
220
100
150
150
180
75
100
125
150
125
150
190
230
165
200
250
300
35
35
35
35
14.5
14.5
14.5
14.5
16
16
16
16
185
185
185
185
17,332
17,791
21,872
22,786
S42
S42
S42
S42
SP2000-0181-5T-XIK0
SP2000-0201-5T-XIK0
SP2000-0218-5T-XIK0
SP2000-0259-5T-XIK0
300
340
400
450
300
340
410
450
250
270
300
380
220
220
270
300
305
330
360
400
380
420
465
560
38
38
38
38
20
20
20
20
16
16
16
16
299
299
299
299
24,956
29,238
32,805
34,353
S52
S52
S52
S52
SP2000-0290-5T-XIK0
SP2000-0314-5T-XIK0
SP2000-0368-5T-XIK0
SP2000-0401-5T-XIK0
480
550
610
770
485
550
610
610
400
450
485
550
340
380
430
480
450
500
560
640
600
665
720
850
38
38
38
38
23
23
23
23
16
16
16.
16
353
353
353
353
49,944
54,652
57,780
67,608
*S65
*S65
*S65
*S65
SP2000-0457-5T-XIK0
SP2000-0524-5T-XIK0
SP2000-0598-5T-XIK0
SP2000-0748-5T-XIK0
860
970
1090
1230
770
860
970
1230
680
770
860
970
550
610
770
860
720
800
900
1000
880
960
1100
1300
55
55
55
55
39
39
39
39
22
22
22
22
970
970
970
970
102,504
112,152
117,458
123,030
*S70
SP2000-0831-5T-XIK0
1360
1360
1090
970
1200
1440
55
48
22
1213
143,414
* Input and Output choke is required for these models.
I-NOM:
I-MAX:
Continuous rated current of the inverter
Maximum current produced by the inverter for 60 seconds every 10 minutes
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - SP2000
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 23
SP2000 SINUS PENTA
LIST PRICES
SP2000 - SINUS PENTA
3 Year Warranty
Flexible I/O
Heat Sink Segregation
Conformal Coating on all boards
Full Metal Casing
Wide Range of Communication Modules
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
690V
690V 3-PHASE IP20/IP00
OVERLOAD CAPACITY
FRAME
SIZE
CATALOGUE NUMBER
HP
LIGHT
120%
HP
STANDARD
140%
HP
HEAVY
175%
HP
STRONG
200%
I-NOM
DIMENSIONS
(APPROX.)
I-MAX
HEIGHT WIDTH
APPROX.
WT. LBS
LIST
PRICE
DEPTH
S14
S14
S14
S14
S14
S14
S14
S14
S14
S14
SP2000-0003-6T-BA2K2
SP2000-0004-6T-BA2K2
SP2000-0006-6T-BA2K2
SP2000-0012-6T-BA2K2
SP2000-0018-6T-BA2K2
SP2000-0019-6T-BA2K2
SP2000-0021-6T-BA2K2
SP2000-0022-6T-BA2K2
SP2000-0024-6T-BA2K2
SP2000-0032-6T-BA2K2
7.5
10
12.5
15
20
25
30
40
50
60
5.5
7.5
10
12.5
15
20
25
30
40
50
5.5
5.5
10
10
15
15
20
30
30
50
4
5.5
7.5
10
12.5
15
15
25
30
40
7
9
11
13
17
21
25
33
40
52
8.5
11
13.5
16
21
25
30
40
48
63
21
21
21
21
21
21
21
21
21
21
11
11
11
11
11
11
11
11
11
11
10
10
10
10
10
10
10
10
10
10
41
41
41
41
41
41
41
41
41
41
4,397
4,493
4,590
4,686
4,783
5,265
5,544
5,855
5,991
6,901
S22
S22
S22
S22
SP2000-0042-6T-BA2K2
SP2000-0051-6T-BA2K2
SP2000-0062-6T-BA2K2
SP2000-0069-6T-BA2K2
75
100
100
125
60
75
100
125
50
75
75
100
40
60
75
75
60
80
85
105
72
96
110
135
33
33
33
33
11
11
11
11
14
14
14
14
119
119
119
119
10,815
11,510
13,198
14,113
S32
S32
S32
S32
SP2000-0076-6T-BA2K2
SP2000-0088-6T-BA2K2
SP2000-0131-6T-BA2K2
SP2000-0164-6T-BA2K2
150
180
220
300
150
180
220
270
125
150
220
250
100
125
150
180
125
150
190
230
165
200
250
300
35
35
35
35
14.5
14.5
14.5
14.5
16
16
16
16
185
185
185
185
17,332
17,791
21,872
22,786
S42
S42
S42
S42
SP2000-0181-6T-XIK0
SP2000-0201-6T-XIK0
SP2000-0218-6T-XIK0
SP2000-0259-6T-XIK0
340
430
485
550
340
430
430
550
300
340
430
485
270
300
340
430
305
330
360
400
380
420
465
560
38
38
38
38
20
20
20
20
16
16
16
16
299
299
299
299
24,956
29,238
32,805
34,353
S52
S52
S52
S52
SP2000-0290-6T-XIK0
SP2000-0314-6T-XIK0
SP2000-0368-6T-XIK0
SP2000-0401-6T-XIK0
610
680
770
860
610
610
680
860
550
610
680
770
480
510
550
680
450
500
560
640
600
665
720
850
38
38
38
38
23
23
23
23
16
16
16
16
353
353
353
353
49,944
54,652
57,780
88,787
*S65
*S65
*S65
*S65
SP2000-0457-6T-XIK0
SP2000-0524-6T-XIK0
SP2000-0598-6T-XIK0
SP2000-0748-6T-XIK0
970
1090
1230
1360
860
970
1230
1360
770
860
970
1230
680
770
860
1090
720
800
900
1000
880
960
1100
1300
55
55
55
55
39
39
39
39
22
22
22
22
970
970
970
970
102,504
112,152
117,458
123,030
*S70
SP2000-0831-6T-XIK0
1690
1500
1360
1230
1200
1440
55
48
22
1213
143,414
* Input and Output choke is required for these models.
I-NOM:
I-MAX:
Continuous rated current of the inverter
Maximum current produced by the inverter for 60 seconds every 10 minutes
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
C - 24
Control Products - SP2000
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
SP2000 SINUS PENTA PERIPHERALS
SP2000 - SINUS PENTA PERIPHERALS
LIST PRICES
Effective 02-11-16
Supercedes All Previous
SP2000 - SINUS PENTA PERIPHERALS
CATALOGUE NUMBER
NOTE:
DESCRIPTION
LIST PRICE
ZZ0101660
SINUS PENTA Keypad
199
ZZ0095700
SINUS PENTA remote keypad kit (includes 5m cable and door mounting)
135
ZZ0095699
SINUS PENTA remote keypad kit (includes 3m cable and door mounting)
120
ZZ0095210
KIT heatsink segregation for S05 Frame Size
131
ZZ0121920
KIT heatsink segregation for S12 Frame Size
144
ZZ0124930
KIT heatsink segregation for S14 Frame Size
225
ZZ0124931
KIT heatsink segregation for S22 Frame Size
375
ZZ0124932
KIT heatsink segregation for S32 Frame Size
375
ZZ0123901
KIT heatsink segregation for S41 Frame Size
330
ZZ0123902
KIT heatsink segregation for S42 Frame Size
330
ZZ0123903
KIT heatsink segregation for S51 Frame Size
330
ZZ0123904
KIT heatsink segregation for S52 Frame Size
330
SPCBS05
Conduit Box NEMA 1 for SINUS PENTA S05
190
SPCBS12
Conduit Box NEMA 1 for SINUS PENTA S12
190
SPCBS14
Conduit Box NEMA 1 for SINUS PENTA S14
210
SPCBS15
Conduit Box NEMA 1 for SINUS PENTA S15
210
SPCBS20
Conduit Box NEMA 1 for SINUS PENTA S20
210
SPCBS22
Conduit Box NEMA 1 for SINUS PENTA S22
270
SPCBS30
Conduit Box NEMA 1 for SINUS PENTA S30
270
SPCBS32
Conduit Box NEMA 1 for SINUS PENTA S32
300
SPCBS42
Conduit Box NEMA 1 for SINUS PENTA S41 & S42
400
SPCBS52
Conduit Box NEMA 1 for SINUS PENTA S52
600
ZZ0095834
Encoder card Multifunction ES836 for SINUS PENTA (Slot A)
181
ZZ0101830
ES860 SINcos card for SINUS PENTA (Slot A)
383
ZZ0101860
ES861 Resolver/Encoder card with Encoder repeated, (3) digital Input/Output (slot C)
741
ZZ0101814
ES847 (8) Digital Input, (6) Transistor Output, (4) PT100 Inputs up to 260ºC, (1) Analog Voltage Input,
(1) Analog Current Input 0-20mA, (slot C)
674
ZZ0101840
ES870 (8) Digital Input, (6) Output relays also for Multi-Pump Application (slot C)
344
ZZ4590010
SW Multipumps control SINUS PENTA
N/C
ZZ0101790
ES914 +24Vdc Supply for SINUS PENTA control
593
ZZ0095620
ES848 Supplier 100W -24Vdc -IP00, Input 300-800Vdc
393
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - SP2000 PERIPHERALS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 25
SP2000 SINUS PENTA PERIPHERALS
LIST PRICES
SP2000 - SINUS PENTA PERIPHERALS
Effective 02-11-16
Supercedes All Previous
SP2000 - SINUS PENTA COMMUNICATION PERIPHERALS
NOTE:
C - 26
CATALOGUE NUMBER
DESCRIPTION
LIST PRICE
PC1604662
Multi End Cable, Sinus Penta, D Connector to RS485 Three Wire (used with WW1420032)
243
WW1420032
USB to RS485 Terminals, (used with PC1604662)
440
SW300007J
SW REMOTE DRIVE ES Ve. 2.30 + Instruction Manual
68
ZZ0095850
ES822 Insulated card RS232 and/or RS485 for SINUS PENTA (This Card Must Be Installed on
the Inverter and It is Suggested for ModBBus Networks) (Slot B)
132
ZZ0101820
ES851 Data Logger - RS-232 (Slot B)
778
ZZ4600013
KIT REMOTE DRIVE for PC (Cables, SW, USB/485 converter, instruction manual
484
ZZ4600030
KIT "ANY-BUS COMMUNICATOR" Converting card Modbus/Profibus DP/Device NET/canbus for
32 drives connection, complete with cables & programming SW
2,494
ZZ4600045
Profibus DP Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
1,252
ZZ4600042
PROFIdrive Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
1,784
ZZ4600055
Devicenet Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
1,713
ZZ4600060
Interbus Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
1,767
ZZ4600070
CANOpen Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
1,814
ZZ4600080
ControlNet Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
2,505
ZZ4600085
Lonworks Card for SINUS PENTA (Kit Hardware and Software) (Slot B)
2,031
ZZ4600100
Ethernet+IT Card for SINS PENTA (Kit Hardware and Software) (Slot B)
2,065
ZZ0102402
BacNet RS485 + ES919 (Slot B)
1,037
ZZ0102404
BacNet Ethernet + ES919 (Slot B)
1,037
ZZ0102406
Metasys N2 + ES919 (Slot B)
745
ZZR0988A0
120/240V Digital Input Card
1,750
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - SP2000 PERIPHERALS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
VMX-SERIES
MODEL:
FEATURES
VMX-SERIES COMPACT SOFT STARTER
DESCRIPTION: VMX Series Low Voltage Soft Starters; The control and
protection you expect in an innovative soft starter design.
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Pumps
• Compressor
• Conveyors
• Chillers
• Blowers
• Fans
FEATURES
• Standard Duty (500% O/L for 20 Sec) & Heavy Duty (500% O/L for 60 sec) Ratings Available
• 9 to 1250A Current Ratings
• Chassis Style or Configured Style Available
• Multiple Ramps to Start Any Load
• Built-In Deceleration Control, Dual ramp, Kick Start and Jog Modes
• Start & Run Protection
• Real Time Thermal Modelling
• Phase Loss Protection
• Electronic Shear Pin
• Built-In Motor Protection
• Short Circuit Protection
• Phase Current Imbalance/Loss protection
• Complete with Bypass Contactor
• Pump Flex Deceleration
• 3 programmable Output Contacts
• Built in RS485 Communications
• Fault History
• Narrow width for MCC Mounting
• Remote Keypad Mounting Option Available
• Units operate on 230, 460 or 600 volts
• 1 Year Warranty
• UL, cUL and CE Approved
Control Products - VMX-SERIES
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 27
VMX-SERIES
LIST PRICES
VMX-SERIES LOW VOLTAGE SOFT-STARTER
Current Ramp or Voltage Ramp, with Current Limit
Complete with Decel Control, Dual Ramp, Kick Start and Jog Modes
Integral up to Speed Bypass Contactor
PTC Thermisor Input
RS-485 Modbus - RTU Communications
120 Volts AC Control
24V DC Dry Contact Inputs, No External DC Power Supply Required
Chassis Mount
Effective 02-11-16
Supercedes All Previous
230V / HP
460V / HP
VOLTAGE:
230V / 460V / 575V
575V / HP
CATALOGUE NUMBER
ADJUSTABLE RANGE
(AMPS)
HD
SD
HD
SD
HD
SD
LIST
PRICE
VMX-18-BP
9-18
5
5
10
10
10
15
2,365
VMX-28-BP
14-28
7.5
7.5
15
20
20
25
2,365
VMX-39-BP
19-39
10
10
25
25
30
30
2,485
VMX-48-BP
24-48
15
15
30
30
30
40
2,485
VMX-62-BP
31-62
20
20
40
40
50
50
2,512
VMX-78-BP
39-78
25
25
50
60
60
60
2,615
VMX-92-BP
46-92
30
30
60
60
75
75
3,102
VMX-112-BP
56-112
30
40
75
75
75
100
3,417
VMX-150-BP
75-150
50
50
100
100
75
125
4,500
VMX-160-BP
80-160
50
60
100
125
75
150
4,812
VMX-210-BP
105-210
60
75
150
150
150
200
6,945
VMX-275-BP
138-275
75
100
150
200
150
200
8,247
VMX-361-BP
181-361
125
125
250
300
300
350
8,900
VMX-450-BP
225-450
150
150
300
350
300
450
9,985
VMX-550-BP
275-550
200
200
400
450
500
500
12,607
VMX-600-BP
300-600
200
200
450
500
600
600
12,835
VMX-862-BP
431-862
300
300
500
600
600
700
18,252
VMX-900-BP
450-900
300
350
600
700
600
900
20,160
SD - Standard Duty 500% - 20 seconds 1.0 S.F. with shunt rated bypass
HD - Heavy Duty 500% - 60 seconds 1.15 S.F. with fully rated bypass
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
(3) Model VMX-210-BP and above utilize an external by-pass contactor (included with softstarter)
DIMENSIONS AND SHIPPING WEIGHTS
CATALOGUE NUMBER
HEIGHT INCHES (mm)
VMX-18-BP thru VMX-48-BP
8.85 (225)
VMX-62-BP thru VMX-112-BP
14 (355.6)
VMX-150-BP thru VMX-160-BP
19 (482.6)
VMX-210-BP
VMX-275-BP
C - 28
WIDTH INCHES (mm)
DEPTH INCHES (mm)
13 (5.9)
8 (203)
6.65 (169)
29.3 (744.2)
VMX-550-BP thru VMX-600-BP
29.5 (749.3)
VMX-862-BP thru VMX-900-BP
44.25 (1124)
VMX-1006-BP thru VMX-1250-BP
50.77 (1289.6)
23 (10.4)
33 (15)
130 (59)
28.1 (713.7)
VMX-361-BP thru VMX-450-BP
APPROX. WT. LBS (kg)
12.5 (317.5)
9.1 (231)
140 (63.5)
145 (65.8)
165 (74.8)
25.5 (647.7)
Control Products - VMX-SERIES
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
11.86 (301.3)
325 (147)
13.28 (337.3)
400 (181)
VMX-STARTERS
LIST PRICES
VMX STARTERS COMPLETE IN NEMA 1 AND NEMA 12
Panel does not include Control Transformer (120Vac Must be fed Externally).
List pricing includes the VMX and the enclosure.
Items on this page are not stocked in TECO-Westinghouse warehouses,
however, are available for quick shipment from the factory.
Please contact your TWMI representative for availability.
To choose the model number refer to page C-35.
Effective 02-11-16
Supercedes All Previous
NEMA 1 ENCLOSURE
VOLTAGE:
230V / 460V / 575V
NEMA 12 ENCLOSURE
DIMENSIONS
CATALOGUE
NUMBER
HEIGHT
WIDTH
DEPTH
VMX-18-BP-N
15
10
VMX-28-BP-N
15
VMX-39-BP-N
DIMENSIONS
LIST PRICE
CATALOGUE
NUMBER
HEIGHT
WIDTH
DEPTH
8
2,745
VMX-18-BP-E
24
16
8
3,790
10
8
2,745
VMX-28-BP-E
24
16
8
3,790
15
10
8
2,865
VMX-39-BP-E
24
16
8
3,910
VMX-48-BP-N
15
10
8
2,865
VMX-48-BP-E
24
16
8
3,910
VMX-62-BP-N
20
10
8
3,115
VMX-62-BP-E
24
16
8
3,937
VMX-78-BP-N
20
10
8
3,220
VMX-78-BP-E
24
16
8
4,040
VMX-92-BP-N
20
10
8
3,705
VMX-92-BP-E
24
16
8
4,527
VMX-112-BP-N
20
10
8
4,022
VMX-112-BP-E
24
16
8
4,845
VMX-150-BP-N
28
10
8
5,255
VMX-150-BP-E
36
24
8
6,007
VMX-160-BP-N
28
10
8
5,567
VMX-160-BP-E
36
24
8
6,317
VMX-210-BP-N
48
24
12
7,942
VMX-210-BP-E
48
24
12
8,842
LIST PRICE
VMX-275-BP-N
48
24
12
9,260
VMX-275-BP-E
48
24
12
10,145
VMX-361-BP-N
48
24
12
9,920
VMX-361-BP-E
48
24
12
10,797
VMX-450-BP-N
60
24
12
11,160
VMX-450-BP-E
60
24
12
12,180
VMX-550-BP-N
60
24
12
13,816
VMX-550-BP-E
60
24
12
14,802
VMX-600-BP-N
60
24
12
14,045
VMX-600-BP-E
60
24
12
15,030
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
CABLE ASSEMBLY FOR REMOTE MOUNTING KEYPAD
CATALOGUE NUMBER
DESCRIPTION
CABLE LENGTH
APPLICABLE MODEL
LIST PRICE
VMX-KP12-KIT2-1
Remote Display Kit
1m Cable
VMX-18 to VMX-48
400
VMX-KP12-KIT2-2
Remote Display Kit
2m Cable
VMX-18 to VMX-48
410
VMX-KP12-KIT2-3
Remote Display Kit
3m Cable
VMX-18 to VMX-48
420
VMX-KP12-KIT-1
Remote Display Kit
1m Cable
VMX-62 and Above
400
VMX-KP12-KIT-2
Remote Display Kit
2m Cable
VMX-62 and Above
410
VMX-KP12-KIT-3
Remote Display Kit
3m Cable
VMX-62 and Above
420
Control Products - VMX-SERIES ENCLOSURES
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 29
VMX-SERIES CONFIGURED
MODEL:
VMX-SERIES COMPACT
SOFT STARTER - CONFIGURED
DESCRIPTION: VMX Series Low Voltage Soft Starters; The control and
protection you expect in an innovative soft starter design.
FEATURES
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Pumps
• Compressor
• Conveyors
• Chillers
• Blowers
• Fans
FEATURES
• Standard Duty (500% O/L for 20 Sec) & Heavy Duty (500% O/L for 60 Sec) Ratings Available
• 9 to 1250A Current Ratings
• Multiple Ramps to Start Any Load
• Built-In Deceleration Control, Dual ramp, Kick Start and Jog Modes
• Start & Run Protection
• Real Time Thermal Modelling
• Phase Loss Protection
• Electronic Shear Pin
• Motor Duty Cycle Protection
• Short Circuit Protection
• Phase Current Imbalance/Loss protection
• Built in Circuit Breaker
• Nema 4/12 Enclosure
• Advanced Motor Protection
• Control Transformer Included
• Door Mounted Keypad and Pilot Devices:
- Digital Keypad
- Start/Stop Button
- Local / Off / Remote Switch
- Motor Run Pilot Light
- Power On Pilot Light
- Start Fault Pilot Light
- E-Stop Fault Pilot Light
- External Interlock Pilot Light
• 1 Year Warranty
• UL, cUL and CE Approved
C - 30
Control Products - VMX-SERIES CONFIGURED
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
DUTY
VMX-SERIES HEAVY
CONFIGURED
LIST PRICES
VMX - SERIES LOW VOLTAGE SOFT-STARTER NEMA 4/12
CONFIGURED SOFT-STARTERS - HEAVY DUTY
WITH CIRCUIT BREAKER
Standard VMX Series Features
HD - Heavy Duty 500% - 60 Seconds 1.15 S.F. with Line Rated Bypass
Built-In Disconnect with Door-Mounted Lockable Operator Handle
NEMA 4/12 Enclosure
Integral Line-Start (ATL) Rated Bypass Contactor - D.O.L. Rated
Advanced Motor Protection
Control Power Transformer
Door Mounted Keypad and Pilot Devices:
- Digital Keypad
- Power On Pilot Light
- Start/Stop Button
- Start Fault Pilot Light
- Local / Off / Remote Switch
- E-Stop Fault Pilot Light
- Motor Run Pilot Light
- External Interlock Pilot Light
CATALOGUE NUMBER
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V / 460V / 575V
LINE AND CONTROL VOLTAGES:
1 = 208V, 120V Ctrl, 50/60Hz
2 = 230V, 120V Ctrl, 50/60Hz
3 = 380V, 220V Ctrl, 50/60Hz
4 = 460V, 120V Ctrl, 50/60Hz
5 = 575V, 120V Ctrl, 50/60Hz
6 = 415V, 220V Ctrl, 50/60Hz
7 = 220V, 220V Ctrl, 50/60Hz
NOMINAL MOTOR HP RATING
MAXIMUM AMP
RATING
208V
230V
460V
575V
LIST
PRICE
VMX-H-21-FS*
21
7.5
7.5
15
15
8,520
VMX-H-27-FS*
27
10
10
25
20
8,725
VMX-H-40-FS*
40
10
15
30
25
8,830
VMX-H-45-CB*
45
15
20
40
30
9,350
VMX-H-55-CB*
55
20
25
50
40
9,870
VMX-H-68-CB*
68
25
30
60
50
10,175
VMX-H-96-CB*
96
30
30
75
60
12,055
VMX-H-125-CB*
125
40
50
100
75
12,735
VMX-H-156-BP*
156
60
60
150
100
14,750
VMX-H-220-CB*
220
60
75
150
150
18,205
VMX-H-248-CB*
248
100
125
250
200
19,365
VMX-H-400-CB*
400
125
150
300
300
23,815
VMX-H-480-CB*
480
150
200
400
500
32,305
VMX-H-600-CB*
600
200
200
500
600
39,675
* Specify line and control voltage.
VMX CONFIGURED STARTER OPTIONS
NOTE:
CATALOGUE NUMBER
DESCRIPTION
LIST PRICE
Option AA
Dual ramp option, includes 2-position switch
193
Option B
Jog option, includes run/jog switch
241
Option H
Enclosure heater with thermostat
802
Option SA
Surge suppressor
802
Option OL
Additional overload relay for backup in X-line mode
481
Option RX
RX Series motor protection/metering relay (door mounted)
1,043
(1) Items on this page are not stocked in TECO-Westinghouse warehouses, however, are available for quick shipment from the factory.
Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - VMX-SERIES HEAVY DUTY CONFIGURED
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 31
DUTY
VMX-SERIES STANDARD
CONFIGURED
LIST PRICES
VMX - SERIES LOW VOLTAGE SOFT-STARTER NEMA 4/12
CONFIGURED SOFT-STARTERS - STANDARD DUTY
WITH CIRCUIT BREAKER
Standard VMX Series Features
SD - Standard Duty 500% - 20 Seconds 1.00 S.F. with a Shunt Rated Bypass
Built-In Disconnect with Door-Mounted Lockable Operator Handle
NEMA 4/12 Enclosure
Advanced Motor Protection
Control Power Transformer
Door Mounted Keypad and Pilot Devices:
- Digital Keypad
- Power On Pilot Light
- Start/Stop Button
- Start Fault Pilot Light
- Local / Off / Remote Switch
- E-Stop Fault Pilot Light
- Motor Run Pilot Light
- External Interlock Pilot Light
CATALOGUE NUMBER
MAXIMUM AMP
RATING
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V / 460V / 575V
LINE AND CONTROL VOLTAGES:
1 = 208V, 120V Ctrl, 50/60Hz
2 = 230V, 120V Ctrl, 50/60Hz
3 = 380V, 220V Ctrl, 50/60Hz
4 = 460V, 120V Ctrl, 50/60Hz
5 = 575V, 120V Ctrl, 50/60Hz
6 = 415V, 220V Ctrl, 50/60Hz
7 = 220V, 220V Ctrl, 50/60Hz
NOMINAL MOTOR HP RATING
208V
230V
460V
575V
LIST
PRICE
VMX-S-18-FS*
18
5
5
10
15
7,420
VMX-S-28-FS*
28
7.5
7.5
20
25
7,420
VMX-S-39-FS*
39
10
10
25
30
7,550
VMX-S-48-FS*
48
10
15
30
40
7,600
VMX-S-62-CB*
62
15
20
40
60
7,630
VMX-S-78-CB*
78
20
25
50
75
8,935
VMX-S-92-CB*
92
25
30
60
75
9,970
VMX-S-112-CB*
112
30
40
75
100
11,010
VMX-S-150-CB*
150
40
50
100
125
12,260
VMX-S-160-CB*
160
50
60
125
150
13,295
VMX-S-210-CB*
210
60
75
150
200
14,960
VMX-S-275-CB*
275
75
100
200
250
17,555
VMX-S-305-CB*
305
100
125
250
300
18,905
VMX-S-361-CB*
361
125
125
300
350
20,150
VMX-S-450-CB*
450
150
150
350
400
20,735
VMX-S-550-CB*
550
150
200
450
500
33,030
VMX-S-600-CB*
600
200
200
500
600
38,120
VMX-S-862-CB*
862
250
300
600
700
42,065
* Specify line and control voltage.
VMX CONFIGURED STARTER OPTIONS
NOTE:
C - 32
CATALOGUE NUMBER
DESCRIPTION
LIST PRICE
Option AA
Dual ramp option, includes 2-position switch
193
Option B
Jog option, includes run/jog switch
241
Option H
Enclosure heater with thermostat
802
Option SA
Surge suppressor
802
Option OL
Additional overload relay for backup in X-line mode
481
Option RX
RX Series motor protection/metering relay (door mounted)
1,043
(1) Items on this page are not stocked in TECO-Westinghouse warehouses, however, are available for quick shipment from the factory.
Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - VMX-SERIES STANDARD DUTY CONFIGURED
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
MVC-PLUS
MODEL:
FEATURES
MVC-PLUS MEDIUM VOLTAGE SOFT-STARTER
Effective 02-11-16
Supercedes All Previous
DESCRIPTION: Advanced Motor Control Protection and Monitoring in a
Reliable Field Proven Soft Starter.
APPLICATIONS
• Pump Systems
• Gas Compression
• Conveyor Systems
• No Load Motor Test Stands
• Aggregate Crushers
• ID Fans & Blowers
FEATURES
• Available Voltage Class: 2300V, 3300V, 4160V, 6000/7200V, 11kV-15kV
• Units Available Up to 10,000 HP at 7.2kV (1500 amps)
• Units Available Up to 20,000 HP at 15kV (800 amps)
• 2,300V-7,200V (60kV BIL) / 11,000-15,000V (110kV BIL)
• Programmable Keypad/Operator with 2 Lines x 20 Character w, Backlit Display
• Up to 12 RTD Inputs Available
• Rugged Full Pulse Gate Firing Circuit
• Custom Packaged Systems Available Including Cascading
• Low Voltage Optically Isolated from Medium Voltage
• 500% current limit for 60 seconds
• Fully Rated Disconnect Switch
• Voltage Ramps with Current Limit
• Pump-Flex Feature Controls Water Hammer
• Built in RS-485 Communication
• Other Communication Protocols Available
• Free Software for Start up and Monitoring
• DV/DT Transient Voltage Protection
• Fully rated Line and Bypass Contactor
• Digital Control Unit on the Low Voltage Door
• Volts, Amps and Power reading for Measurement and Protection
• Motor and Starter Protection:
- Phase Imbalance
- Short Circuit Detection
- Over / Under Voltage
- Starter Over-Temp
- Starts Per Hour Lockout
- Phase Reversal
- Over / Under Current
- Shorted SCR
- Coast Down Lockout
- Time Between Starts
• NEMA 12 Enclosure Standard (3R Enclosure Optional)
• 3 Year Warranty with Factory Start-Up
• UL, cUL and CE Approved
Control Products - MVC-PLUS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 33
MVC-PLUS
LIST PRICES
MVC-PLUS MEDIUM VOLTAGE SOFT-STARTER
Load-break Disconnect Switch with Door Safety Interlock
Main Isolation Vacuum Contactor
Fully Rated Bypass Contactor
Heavy Duty SCR Stacks with Ring Transformer Isolation
Fiber Optically Isolated Low Voltage Compartment
8 Programmable Relay Outputs for Control Flexibility
2 Programmable Analog Outputs (0-10vdc or 4-20ma)
RS-485 Communications (Modbus RTU)
NEMA 12 Gasketed Enclosure
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
2300V / 4160V /
6600V / 11000V /
13800V
2300V
CATALOGUE NUMBER
MAX AMPS
HP
LIST PRICE
MVC4-23100-E-SWG
100
350
61,347
MVC4-23200-E-SWG
200
700
61,630
MVC4-23400-E-SWG
400
1400
62,215
MVC4-23600-E-SWG
630
2700
105,500
HP
LIST PRICE
4160V
CATALOGUE NUMBER
MAX AMPS
MVC4-41100-E-SWG
100
600
76,447
MVC4-41200-E-SWG
200
1250
78,260
MVC4-41400-E-SWG
400
2500
85,207
MVC4-41600-E-SWG
630
4000
167,300
MVC4-411000-E-SWG
1000
7200
406,100
HP
LIST PRICE
6600V
CATALOGUE NUMBER
MAX AMPS
MVC4-66100-E-SWG
100
1000
76,070
MVC4-66200-E-SWG
200
2000
98,930
MVC4-66400-E-SWG
400
4000
106,367
MVC4-66600-E-SWG
630
7400
190,700
11000V
CATALOGUE NUMBER
MAX AMPS
HP
LIST PRICE
MVC4-110200-E-SWG
200
3400
398,300
MVC4-110400-E-SWG
400
6700
430,255
MVC4-110600-E-SWG
630
10,600
561,200
13800V
NOTE:
C - 34
CATALOGUE NUMBER
MAX AMPS
HP
LIST PRICE
MVC4-138100-E-SWG
100
2100
430,255
MVC4-138200-E-SWG
200
4200
466,700
MVC4-138400-E-SWG
400
8500
527,400
MVC4-138600-E-SWG
600
12500
813,400
MVC4-1381000-E-SWG
1000
21000
1,137,900
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
(3) Size units based on motor amps including service factor.
Control Products - MVC-PLUS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
MV SOFT STARTER
DIMENSIONS
LIST PRICES
MV SOFT STARTER DIMENSIONS
Effective 02-11-16
Supercedes All Previous
DIMENSIONS
VOLTAGE
CATALOGUE NUMBER
HEIGHT
WIDTH
DEPTH
92
36
30
93
81
44
92
36
30
MVC4-23100-E-SWG
2300
MVC4-23200-E-SWG
MVC4-23400-E-SWG
MVC4-23600-E-SWG
MVC4-41100-E-SWG
MVC4-41200-E-SWG
4160
MVC4-41400-E-SWG
MVC4-41600-E-SWG
92
72
30
MVC4-411000-E-SWG
92
81
44
92
42
30
92
117
30
95
126
44
95
126
44
95
120
80
MVC4-66100-E-SWG
6600
MVC4-66200-E-SWG
MVC4-66400-E-SWG
MVC4-66600-E-SWG
MVC4-110200-E-SWG
11000V
MVC4-110400-E-SWG
MVC4-110600-E-SWG
MVC4-138100-E-SWG
MVC4-138200-E-SWG
13800V
MVC4-138400-E-SWG
MVC4-138600-E-SWG
MVC4-1381000-E-SWG
MV - ACROSS THE LINE STARTER
MEDIUM VOLTAGE ACROSS THE LINE STARTER
CATALOGUE NUMBER
VOLTAGE
MVC4-23200-E-DOL
MVC4-23400-E-DOL
2300
MVC4-23600-E-DOL
AMPS
HP
200
700
400
1400
600
2100
DIMENSIONS
HEIGHT
WIDTH
DEPTH
92
36
30
92
72
30
LIST PRICE
39,072
42,470
76,447
MEDIUM VOLTAGE ACROSS THE LINE STARTER
CATALOGUE NUMBER
VOLTAGE
MVC4-41200-E-DOL
MVC4-41400-E-DOL
MVC4-41600-E-DOL
NOTE:
(1)
(2)
(3)
(4)
(5)
4160
AMPS
HP
200
1250
400
2500
600
3800
DIMENSIONS
HEIGHT
WIDTH
DEPTH
92
36
30
92
72
30
LIST PRICE
49,265
56,062
98,532
Max Amperage must be lower than Motor Full load current x Motor Service Factor.
Motor Current and Service Factor must be supplied on order for Fuse and CT selection.
Estimate assumes motor power factor = 0.8 or better, Motor Efficiency is 0.95 or better and S.F. = 1.15.
Prices subject to change without notice.
F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - MV - ACROSS THE LINE STARTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 35
MTE REACTORS
MODEL:
MTE REACTORS
DESCRIPTION: RL Line/Load Reactors Solve Line and Load Power
Quality Problems
APPLICATIONS
• Harmonic Compensation
• Output of Drive System
• Input of Drive System
FEATURES
• 1 to 1,500 Amp Current range
• 208V to 690V, 50/60Hz, 3-Phase
• Available for use on Single Phase Input
• Epoxy Impregnated
• High Saturation Current Rating
• For use on VFD Systems with Switching Frequencies up to 20kHz
• 150% O/L Rated
• Protects Motors from Long lead Lengths
• Reduce Output Voltage dV/dT
• Virtually Eliminate Nuisance Tripping
• Extended Semiconductor Life
• Transient Protection Options Available
• Reduce Motor Temperature
• Reduce Motor Audible Noise
• Available in Chassis Style, NEMA 1 and NEMA 3R
• UL, cUL, CSA and CE Approved
C - 36
FEATURES
Control Products - MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
Effective 02-11-16
Supercedes All Previous
208V-3% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
208V 3-PHASE 3% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00802
1
RL-00801
VOLTAGE:
208V-3%
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
8
4.8
6
3
8
217
CAB-8
158
1.5
8
4.8
6
3
7
193
CAB-8
158
RL-01201
2
12
5
6
3.3
9
228
CAB-8
158
RL-01801
3
18
5.3
6
3.2
9
298
CAB-8
158
RL-02501
5
25
5.8
7.2
3.5
11
312
CAB-13V
210
RL-03501
7.5
35
5.8
7.2
4
14
352
CAB-13V
210
RL-04501
10
45
7.4
9
4.7
23
463
CAB-13V
210
RL-05501
15
55
7.3
9
5.3
24
587
CAB-13V
210
RL-08001
20
80
7.2
9
6.3
25
598
CAB-13V
210
RL-10001
25
100
7.3
9
6.5
29
766
CAB-13V
210
RL-13001
30
130
7
9
4.66
29
848
CAB-13V
210
RL-13001
40
130
7
9
4.66
29
848
CAB-13V
210
RL-16001
50
160
7.2
9
6.8
41
1,078
CAB-13V
210
RL-20001B14
60
200
7.5
9
7.3
38
1,135
CAB-13V
210
RL-25001B14
75
250
7.5
9
9
47
1,455
CAB-13V
210
RL-32001B14
100
320
9
10.8
8.3
80
2,141
CAB-17V
569
RL-50001B14
125
500
9
10.8
10.5
93
2,364
CAB-17V
569
RL-50001B14
150
500
9
10.8
10.5
93
2,364
CAB-17V
569
RL-60001
200
600
11.5
14.4
10
120
3,776
CAB-26C
1,673
RL-75001
250
750
11.5
14.4
11
140
4,842
CAB-26C
1,673
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 208V-3% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 37
208V-5% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
208V 3-PHASE 5% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00802
1
RL-00802
RL-01202
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
8
4.8
6
3
8
217
CAB-8
158
1.5
8
4.8
6
3
8
217
CAB-8
158
2
12
5
6
3.3
10
242
CAB-8
158
RL-01802
3
18
5.3
6
3.5
12
305
CAB-8
158
RL-02502
5
25
5.8
7.2
3.5
14
352
CAB-13V
210
RL-03502
7.5
35
5.8
7.2
4
16
370
CAB-13V
210
RL-05502
10
55
7
9
5.3
27
640
CAB-13V
210
RL-08002
15
80
7.2
9
6.5
33
853
CAB-13V
210
RL-10002
20
100
7.3
9
6.8
37
841
CAB-13V
210
RL-08001
25
80
7.2
9
6.3
25
598
CAB-13V
210
RL-10001
30
100
7.3
9
6.5
29
766
CAB-13V
210
RL-13001
40
130
7
9
4.66
29
848
CAB-13V
210
RL-16001
50
160
7.2
9
6.8
41
1,078
CAB-13V
210
RL-20002B14
60
200
7.5
9
8.3
54
1,668
CAB-13V
210
RL-25002B14
75
250
8.5
10.8
9
80
2,120
CAB-17V
569
RL-32001B14
100
320
9
10.8
8.3
80
2,141
CAB-17V
569
RL-50002
125
500
11.5
14.4
11.5
118
4,379
CAB-26C
569
RL-60002
150
600
11.25
14.4
12
175
4,894
CAB-26C
1,673
RL-60001
200
600
11.5
14.4
10
120
3,776
CAB-26C
1,673
RL-75002
250
750
11.5
14.4
12.5
190
6,100
CAB-26C
1,673
NOTE:
C - 38
VOLTAGE:
208V-5%
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 208V-5% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
240V-3% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
240V 3-PHASE 3% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00401
1
RL-00801
VOLTAGE:
240V-3%
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
4
4.1
4.4
2.8
4
184
CAB-8
158
1.5
8
4.8
6
3
7
193
CAB-8
158
RL-00801
2
8
4.8
6
3
7
193
CAB-8
158
RL-01201
3
12
5
6
3.3
9
228
CAB-8
158
RL-01801
5
18
5.3
6
3.2
9
298
CAB-8
158
RL-02501
7.5
25
5.8
7.2
3.5
11
312
CAB-13V
210
RL-03501
10
35
5.8
7.2
4
14
352
CAB-13V
210
RL-04501
15
45
7.4
9
4.7
23
463
CAB-13V
210
RL-08001
20
80
7.2
9
6.3
25
598
CAB-13V
210
RL-10001
25
100
7.3
9
6.5
29
766
CAB-13V
210
RL-10001
30
100
7.3
9
6.5
29
766
CAB-13V
210
RL-13001
40
130
7
9
4.66
29
848
CAB-13V
210
RL-13001
50
130
7
9
4.66
29
848
CAB-13V
210
RL-16001
60
160
7.2
9
6.8
41
1,078
CAB-13V
210
RL-20001B14
75
200
7.5
9
7.3
38
1,135
CAB-13V
210
RL-25001B14
100
250
7.5
9
9
47
1,455
CAB-13V
210
RL-32001B14
125
320
9
10.8
8.3
80
2,141
CAB-17V
569
RL-40001B14
150
400
10
10.8
10
84
2,357
CAB-17V
569
RL-50001B14
200
500
9
10.8
10.5
93
2,364
CAB-17V
569
RL-60001
250
600
11.5
14.4
10
120
3,776
CAB-26C
1,673
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 240V-3% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 39
240V-5% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
240V 3-PHASE 5% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00803
1
RL-00802
RL-00802
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
8
4.8
6
3.4
11
263
CAB-8
158
1.5
8
4.8
6
3
8
217
CAB-8
158
2
8
4.8
6
3
8
217
CAB-8
158
RL-01202
3
12
5
6
3.3
10
242
CAB-8
158
RL-01802
5
18
5.3
6
3.5
12
305
CAB-8
158
RL-03502
7.5
35
5.8
7.2
4
16
370
CAB-13V
210
RL-03502
10
35
5.8
7.2
4
16
370
CAB-13V
210
RL-05502
15
55
7
9
5.3
27
640
CAB-13V
210
RL-08002
20
80
7.2
9
6.5
33
853
CAB-13V
210
RL-10002
25
100
7.3
9
6.8
37
841
CAB-13V
210
RL-10002
30
100
7.3
9
6.8
37
841
CAB-13V
210
RL-13002
40
130
7.2
9
6.8
43
1,116
CAB-13V
210
RL-13001
50
130
7
9
4.66
29
848
CAB-13V
210
RL-16002
60
160
8.3
10.8
6
50
1,602
CAB-13V
210
RL-20002B14
75
200
7.5
9
8.3
54
1,668
CAB-13V
210
RL-25002B14
100
250
8.5
10.8
9
80
2,120
CAB-17V
569
RL-32002B14
125
320
9
10.8
10
102
2,449
CAB-17V
569
RL-40002B14
150
400
11.25
15
11.5
118
3,932
CAB-17V
569
RL-50002
200
500
11.5
14.4
11.5
118
4,379
CAB-26C
1,673
RL-60002
250
600
11.25
14.4
12
175
4,894
CAB-26C
1,673
NOTE:
C - 40
VOLTAGE:
240V-5%
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 240V-5% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
480V-3% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
480V 3-PHASE 3% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00201
1
RL-00402
VOLTAGE:
480V-3%
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
2
4.1
4.4
2.8
4
182
CAB-8
158
1.5
4
4.1
4.4
2.8
4
189
CAB-8
158
RL-00402
2
4
4.1
4.4
2.8
4
189
CAB-8
158
RL-00803
3
8
4.8
6
3.4
11
263
CAB-8
158
RL-00802
5
8
4.8
6
3
8
217
CAB-8
158
RL-01202
7.5
12
5
6
3.3
10
242
CAB-8
158
RL-01802
10
18
5.3
6
3.5
12
305
CAB-8
158
RL-02502
15
25
5.8
7.2
3.5
14
352
CAB-13V
210
RL-03502
20
35
5.8
7.2
4
16
370
CAB-13V
210
RL-03502
25
35
5.8
7.2
4
16
370
CAB-13V
210
RL-04502
30
45
7.4
9
4.7
28
555
CAB-13V
210
RL-05502
40
55
7
9
5.3
27
640
CAB-13V
210
RL-08002
50
80
7.2
9
6.5
33
853
CAB-13V
210
RL-08002
60
80
7.2
9
6.5
33
853
CAB-13V
210
RL-10002
75
100
7.3
9
6.8
37
841
CAB-13V
210
RL-13002
100
130
7.2
9
6.8
43
1,116
CAB-13V
210
RL-16002
125
160
8.3
10.8
6
50
1,602
CAB-13V
210
RL-20002B14
150
200
7.5
9
8.3
54
1,668
CAB-13V
210
RL-25002B14
200
250
8.5
10.8
9
80
2,120
CAB-17V
569
RL-32002B14
250
320
9
10.8
10
102
2,449
CAB-17V
569
RL-40002B14
300
400
11.25
15
11.5
118
3,932
CAB-17V
569
RL-50002
350
500
11.5
14.4
11.5
118
4,379
CAB-26C
1,673
RL-50002
400
500
11.5
14.4
11.5
118
4,379
CAB-26C
1,673
RL-60002
500
600
11.25
14.4
12
175
4,894
CAB-26C
1,673
RL-75002
600
750
11.5
14.4
12.5
190
6,100
CAB-26C
1,673
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 480V-3% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 41
480V-5% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
480V 3-PHASE 5% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00202
1
RL-00404
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
2
4.1
4.4
2.8
4
191
CAB-8
158
1.5
4
4.1
4.4
3.4
6
226
CAB-8
158
RL-00404
2
4
4.1
4.4
3.4
6
226
CAB-8
158
RL-00804
3
8
4.8
6
3.4
13
303
CAB-8
158
RL-00803
5
8
4.8
6
3.4
11
263
CAB-8
158
RL-01203
7.5
12
5
6
3.9
18
347
CAB-8
158
RL-01803
10
18
6.1
8.1
4
16
403
CAB-13V
210
RL-02503
15
25
5.8
7.2
4.3
20
459
CAB-13V
210
RL-03503
20
35
7.4
9
4.7
30
562
CAB-13V
210
RL-03503
25
35
7.4
9
4.7
30
562
CAB-13V
210
RL-04503
30
45
7.3
9
5.3
39
710
CAB-13V
210
RL-05503
40
55
7
9
6
41
845
CAB-13V
210
RL-08003
50
80
8.5
10.8
6.8
61
1,489
CAB-13V
210
RL-08003
60
80
8.5
10.8
6.8
61
1,489
CAB-13V
210
RL-10003
75
100
8.25
10.8
6.16
74
1,684
CAB-13V
210
RL-13003
100
130
8.5
11
6.16
64
1,696
CAB-13V
210
RL-16003
125
160
8.5
11.5
9
67
1,875
CAB-13V
210
RL-20003B14
150
200
8.3
10.8
10
100
2,448
CAB-13V
210
RL-25003B14
200
250
11.2
14.4
10.3
125
3,815
CAB-17V
569
RL-32003B14
250
320
11.25
14.4
10.5
160
4,121
CAB-17V
569
RL-40003B14
300
400
11.25
14.4
12.5
149
4,563
CAB-17V
569
RL-50003
350
500
11.5
14.4
13.3
210
5,190
CAB-26C
1,673
RL-50003
400
500
11.5
14.4
13.3
210
5,190
CAB-26C
1,673
RL-60003
500
600
11.25
14.4
15
270
6,608
CAB-26C
1,673
RL-75003
600
750
14.5
14.4
14
265
8,530
CAB-26C
1,673
NOTE:
C - 42
VOLTAGE:
480V-5%
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 480V-5% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
600V-3% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
600V 3-PHASE 3% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00202
1
RL-00201
VOLTAGE:
600V-3%
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
2
4.1
4.4
2.8
4
191
CAB-8
158
1.5
2
4.1
4.4
2.8
4
182
CAB-8
158
RL-00403
2
4
4.1
4.4
3.4
5
198
CAB-8
158
RL-00402
3
4
4.1
4.4
2.8
4
189
CAB-8
158
RL-00803
5
8
4.8
6
3.4
11
263
CAB-8
158
RL-01202
7.5
12
5
6
3.3
10
242
CAB-8
158
RL-01202
10
12
5
6
3.3
10
242
CAB-8
158
RL-01802
15
18
5.3
6
3.5
12
305
CAB-8
158
RL-02502
20
25
5.8
7.2
3.5
14
352
CAB-13V
210
RL-02502
25
25
5.8
7.2
3.5
14
352
CAB-13V
210
RL-03502
30
35
5.8
7.2
4
16
370
CAB-13V
210
RL-04502
40
45
7.4
9
4.7
28
555
CAB-13V
210
RL-05502
50
55
7
9
5.3
27
640
CAB-13V
210
RL-08002
60
80
7.2
9
6.5
33
853
CAB-13V
210
RL-08002
75
80
7.2
9
6.5
33
853
CAB-13V
210
RL-10002
100
100
7.3
9
6.8
37
841
CAB-13V
210
RL-13002
125
130
7.2
9
6.8
43
1,116
CAB-13V
210
RL-16002
150
160
8.3
10.8
6
50
1,602
CAB-13V
210
RL-20002B14
200
200
7.5
9
8.3
54
1,668
CAB-13V
210
RL-25002B14
250
250
8.5
10.8
9
80
2,120
CAB-17V
569
RL-32002B14
300
320
9
10.8
10
102
2,449
CAB-17V
569
RL-40002B14
350
400
11.25
15
11.5
118
3,932
CAB-17V
569
RL-40002B14
400
400
11.25
15
11.5
118
3,932
CAB-17V
569
RL-50002
500
500
11.5
14.4
11.5
118
4,379
CAB-26C
1,673
RL-60002
600
600
11.25
14.4
12
175
4,894
CAB-26C
1,673
RL-75002
700
750
11.5
14.4
12.5
190
6,100
CAB-26C
1,673
NOTE:
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 600V-3% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 43
600V-4% MTE REACTORS
LIST PRICES
LINE & LOAD REACTORS: CHASSIS 3-PHASE
Effective 02-11-16
Supercedes All Previous
600V 3-PHASE 4% IMPEDANCE
CATALOGUE NUMBER
HP
RATING
AMPS
RL-00203
1
RL-00202
OPTIONAL
DIMENSIONS (APPROX.)
HEIGHT
WIDTH
DEPTH
APPROX. WT.
LBS
LIST
PRICE
NEMA 1
ENCLOSURE
LIST
PRICE
2
4.1
4.4
2.8
4
219
CAB-8
158
1.5
2
4.1
4.4
2.8
4
191
CAB-8
158
RL-00404
2
4
4.1
4.4
3.4
6
226
CAB-8
158
RL-00404
3
4
4.1
4.4
3.4
6
226
CAB-8
158
RL-00804
5
8
4.8
6
3.4
13
303
CAB-8
158
RL-01203
7.5
12
5
6
3.9
18
347
CAB-8
158
RL-01203
10
12
5
6
3.9
18
347
CAB-8
158
RL-01803
15
18
6.1
8.1
4
16
403
CAB-13V
210
RL-02503
20
25
5.8
7.2
4.3
20
459
CAB-13V
210
RL-02503
25
25
5.8
7.2
4.3
20
459
CAB-13V
210
RL-03503
30
35
7.4
9
4.7
30
562
CAB-13V
210
RL-04503
40
45
7.3
9
5.3
39
710
CAB-13V
210
RL-05503
50
55
7
9
6
41
845
CAB-13V
210
RL-08003
60
80
8.5
10.8
6.8
61
1,489
CAB-13V
210
RL-08003
75
80
8.5
10.8
6.8
61
1,489
CAB-13V
210
RL-10003
100
100
8.25
10.8
6.16
74
1,684
CAB-13V
210
RL-13003
125
130
8.5
11
6.16
64
1,696
CAB-13V
210
RL-16003
150
160
8.5
11.5
9
67
1,875
CAB-13V
210
RL-20003B14
200
200
8.3
10.8
10
100
2,448
CAB-13V
210
RL-25003B14
250
250
11.2
14.4
10.3
125
3,815
CAB-17V
569
RL-32003B14
300
320
11.25
14.4
10.5
160
4,121
CAB-17V
569
RL-40003B14
350
400
11.25
14.4
12.5
149
4,563
CAB-17V
569
RL-40003B14
400
400
11.25
`14.4
12.5
149
4,563
CAB-17V
569
RL-50003
500
500
11.5
14.4
13.3
210
5,190
CAB-26C
1,673
RL-60003
600
600
11.25
14.4
15
270
6,608
CAB-26C
1,673
RL-75003
700
750
14.5
14.4
14
265
8,530
CAB-26C
1,673
NOTE:
C - 44
VOLTAGE:
600V-4%
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - 600V-4% MTE REACTORS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
MTE SERIES
MODEL:
FEATURES
MTE SERIES D dV/dT FILTERS
DESCRIPTION: Designed to protect AC Motors from the destructive effects
of peak voltages facilitated by long cable runs between the
inverter and motor.
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Submersible Pumps
• Process Automation Lines
• HVAC Equipment
FEATURES
• 3 to 600 Amp Range (0.5 to 600HP)
• 480V to 600V, 50/60 Hz, 3-Phase
• Max. Motor Peak Voltage Spec. (150% of DC Bus Voltage) at 1000 Feet
• For use on VFD Systems with Switching Frequencies 2kHz to 5kHz
• Protects Motors from Long lead Lengths and Standing Wave Phenomenon
• Reduce Output Voltage dV/dT
• Available in Chassis Style, NEMA 1 and NEMA 3R
• 1 Year Warranty
• cUL, CE Approved
Control Products - MTE SERIES dV/dT FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 45
MTE SERIES
LIST PRICES
dV/dT FILTERS
Protects Motors from Effects of Peak Voltages Caused by Long Cable Runs
Select Filters Based on the Current Rating of the Motor
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
480V
SERIES A dV/dT FILTER, 480VAC, 60 Hz
OPEN CHASSIS
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE NUMBER
LIST PRICE
CATALOGUE NUMBER
LIST PRICE
CATALOGUE NUMBER
LIST PRICE
1 to 1.5
3
DVSP0003E
710
DVSG0003E
1,115
DVSW0003E
1,625
2
4
DVSP0004E
725
DVSG0004E
1,130
DVSW0004E
1,635
3
7
DVSP0007E
760
DVSG0007E
1,170
DVSW0007E
1,665
5
9
DVSP0009E
790
DVSG0009E
1,205
DVSW0009E
1,700
7.5
12
DVSP0012E
830
DVSG0012E
1,255
DVSW0012E
1,775
10
17
DVSP0017E
910
DVSG0017E
1,340
DVSW0017E
1,810
15
22
DVSP0022E
980
DVSG0022E
1,405
DVSW0022E
1,965
20
27
DVSP0027E
1,050
DVSG0027E
1,480
DVSW0027E
2,085
25
35
DVSP0035E
1,140
DVSG0035E
1,580
DVSW0035E
2,155
30
45
DVSP0045E
1,255
DVSG0045E
1,710
DVSW0045E
2,225
40
55
DVSP0055E
1,355
DVSG0055E
1,830
DVSW0055E
3,105
50
65
DVSP0065E
1,480
DVSG0065E
1,975
DVSW0065E
3,165
60
80
DVSP0080E
1,650
DVSG0080E
2,165
DVSW0080E
3,340
75
110
DVSP0110E
2,060
DVSG0110E
2,625
DVSW0110E
3,995
100
130
DVSP0130E
2,420
DVSG0130E
3,250
DVSW0130E
4,655
125
160
DVSP0160E
2,690
DVSG0160E
3,580
DVSW0160E
4,745
150
200
DVSP0200E
2,860
DVSG0200E
3,835
DVSW0200E
4,830
200
250
DVSP0250E
3,205
DVSG0250E
4,220
DVSW0250E
5,050
250
305
DVSP0305E
3,445
DVSG0305E
4,630
DVSW0305E
5,095
300
365
DVSP0365E
3,855
DVSG0365E
5,165
DVSW0365E
6,485
350
415
DVSP0415E
4,115
DVSG0415E
5,420
DVSW0415E
6,935
450
515
DVSP0515E
4,910
DVSG0515E
6,395
DVSW0515E
7,180
500
600
DVSP0600E
5,100
DVSG0600E
6,755
DVSW0600E
7,365
NOTE:
C - 46
(1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - MTE SERIES dV/dT FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
MTE SERIES
LIST PRICES
dV/dT FILTERS
Protects Motors from Effects of Peak Voltages Caused by Long Cable Runs
Select Filters Based on the Current Rating of the Motor
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
600V
SERIES A dV/dT FILTER, 600VAC, 60 Hz
OPEN CHASSIS
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE NUMBER
LIST PRICE
CATALOGUE NUMBER
LIST PRICE
CATALOGUE NUMBER
LIST PRICE
1 to 2
3
DVSP0003E
710
DVSG0003E
1,115
DVSW0003E
1,625
3
4
DVSP0004E
725
DVSG0004E
1,130
DVSW0004E
1,635
5
7
DVSP0007E
760
DVSG0007E
1,170
DVSW0007E
1,665
7.5
9
DVSP0009E
790
DVSG0009E
1,205
DVSW0009E
1,700
10
12
DVSP0012E
830
DVSG0012E
1,255
DVSW0012E
1,775
15
17
DVSP0017E
910
DVSG0017E
1,340
DVSW0017E
1,810
20
22
DVSP0022E
980
DVSG0022E
1,405
DVSW0022E
1,965
25
27
DVSP0027E
1,050
DVSG0027E
1,480
DVSW0027E
2,085
30
35
DVSP0035E
1,140
DVSG0035E
1,580
DVSW0035E
2,155
40
45
DVSP0045E
1,255
DVSG0045E
1,710
DVSW0045E
2,225
50
55
DVSP0055E
1,355
DVSG0055E
1,830
DVSW0055E
3,105
60
65
DVSP0065E
1,480
DVSG0065E
1,975
DVSW0065E
3,165
75
80
DVSP0080E
1,650
DVSG0080E
2,165
DVSW0080E
3,340
100
110
DVSP0110E
2,060
DVSG0110E
2,625
DVSW0110E
3,995
125
130
DVSP0130E
2,420
DVSG0130E
3,250
DVSW0130E
4,655
150
160
DVSP0160E
2,690
DVSG0160E
3,580
DVSW0160E
4,745
200
200
DVSP0200E
2,860
DVSG0200E
3,835
DVSW0200E
4,830
250
250
DVSP0250E
3,205
DVSG0250E
4,220
DVSW0250E
5,050
300
305
DVSP0305E
3,445
DVSG0305E
4,630
DVSW0305E
5,095
350
365
DVSP0365E
3,855
DVSG0365E
5,165
DVSW0365E
6,485
450
415
DVSP0415E
4,115
DVSG0415E
5,420
DVSW0415E
6,935
500
515
DVSP0515E
4,910
DVSG0515E
6,395
DVSW0515E
7,180
550
515
DVSP0515E
4,910
DVSG0515E
6,395
DVSW0515E
7,180
600
600
DVSP0600E
5,100
DVSG0600E
6,755
DVSW0600E
7,365
NOTE:
(1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - MTE SERIES dV/dT FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 47
MTE SINE WAVE FILTERS
MODEL:
MTE SINE WAVE FILTERS
DESCRIPTION: MTE Sine Wave Filters transform the output of a Variable
Frequency Drive to a near perfect sinusoidal wave form.
APPLICATIONS
• Long Cable Runs
• VFD Feeding a Step Up Transformer
• Multi Motor Applications
• Reduced Motor Noise
FEATURES
• 2 to 700 Amp Current Range
• 230, 480 & 600V, 50/60Hz, 3-Phase
• For Use on VFD Systems with Switching Frequencies from 2kHz to 8kHz
• 100% Rated RMS Current & Intermittent Current of 150% for 1 Minute
• Protects Motors from Long Lead Lengths
• Reduce Motor Temperature
• Reduce Motor Audible Noise
• Available in Chassis Style, NEMA 1 and NEMA 3R
• cUL and CE Approved
C - 48
FEATURES
Control Products - MTE SINE WAVE FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
Effective 02-11-16
Supercedes All Previous
MTE SINE WAVE FILTERS
LIST PRICES
SINE WAVE FILTERS
Designed to provide a pure sine wave output when driven from a VFD
Select filters based on the current rating of the motor
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
230V
SINE WAVE FILTERS 230VAC 60Hz
OPEN CHASSIS
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
0.75 - 1
5
SWAP0005A
1,419
SWAGA0005A
1,637
SWAWA0005A
2,427
2
9
SWAP0009A
1,613
SWAGA0009A
1,896
SWAWA0009A
2,678
3
12
SWAP0012A
1,643
SWAGA0012A
1,926
SWAWA0012A
2,708
5
17
SWAP0017A
1,672
SWAGA0017A
1,953
SWAWA0017A
2,736
7.5
22
SWAP0022A
1,720
SWAGB0022A
2,643
SWAWB0022A
3,262
NOTE:
10
30
SWAP0030A
1,908
SWAGB0030A
2,829
SWAWB0030A
3,448
15
45
SWAP0045A
2,199
SWAGB0045A
3,082
SWAWB0045A
3,701
20
55
SWAP0055A
2,299
SWAGB0055A
3,182
SWAWB0055A
3,801
25
70
SWAP0070A
2,610
SWAGC0070A
4,523
SWAWC0070A
4,860
30
85
SWAP0085A
2,977
SWAGC0085A
4,948
SWAWC0085A
5,286
40
110
SWAP0110A
4,188
SWAGC0110A
5,749
SWAWC0110A
6,086
50
135
SWAP0135A
4,311
SWAGC0135A
5,847
SWAWC0135A
6,184
60
160
SWAP0160A
5,111
SWAGC0160A
6,866
SWAWC0160A
7,204
75
200
SWAP0200A
5,264
SWAGC0200A
8,392
SWAWC0200A
8,731
100
250
SWAP0250A
6,732
SWAGD0250A
10,985
SWAWD0250A
11,450
125
320
SWAP0320A
8,969
SWAGD0320A
12,946
SWAWD0320A
13,412
(1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - MTE SINE WAVE FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 49
MTE SINE WAVE FILTERS
LIST PRICES
SINE WAVE FILTERS
Designed to provide a pure sine wave output when driven from a VFD
Select filters based on the current rating of the motor
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
460V
SINE WAVE FILTERS 460VAC 60Hz
OPEN CHASSIS
NOTE:
C - 50
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
1.5
3
SWGM0003D
1,517
SWGG0003D
1,774
SWGW0003D
2,245
3
5
SWGM0005D
1,573
SWGG0005D
1,838
SWGW0005D
2,321
4
7
SWGM0007D
1,627
SWGG0007D
1,903
SWGW0007D
2,396
5.5
9
SWGM0009D
1,683
SWGG0009D
1,967
SWGW0009D
2,472
7.5
12
SWGM0012D
1,766
SWGG0012D
2,064
SWGW0012D
2,584
10
17
SWGM0017D
1,903
SWGG0017D
2,225
SWGW0017D
2,774
15
22
SWGM0022D
2,040
SWGG0022D
2,387
SWGW0022D
2,962
20
27
SWGM0027D
2,177
SWGG0027D
2,548
SWGW0027D
3,150
25
35
SWGM0035D
2,398
SWGG0035D
2,806
SWGW0035D
3,451
30
45
SWGM0045D
2,674
SWGG0045D
3,128
SWGW0045D
3,827
40
55
SWGM0055D
2,950
SWGG0055D
3,451
SWGW0055D
4,205
50
65
SWGM0065D
3,224
SWGG0065D
3,773
SWGW0065D
4,581
60
80
SWGM0080D
3,638
SWGG0080D
4,256
SWGW0080D
5,147
75
110
SWGM0110D
4,732
SWGG0110D
6,306
SWGW0110D
6,731
100
130
SWGM0130D
5,462
SWGG0130D
7,200
SWGW0130D
7,618
125
160
SWGM0160D
6,556
SWGG0160D
8,542
SWGW0160D
8,950
150
200
SWGM0200D
8,017
SWGG0200D
10,332
SWGW0200D
10,724
200
250
SWGM0250D
9,841
SWGG0250D
12,568
SWGW0250D
12,943
250
305
SWGM0305D
11,848
SWGG0305D
15,028
SWGW0305D
15,384
300
365
SWGM0365D
14,039
SWGG0365D
17,711
SWGW0365D
18,045
350
415
SWGM0415D
15,863
SWGG0415D
19,949
SWGW0415D
20,264
450
515
SWGM0515D
19,512
SWGG0515D
24,421
SWGW0515D
24,701
500
600
SWGM0600D
22,614
SWGG0600D
28,223
SWGW0600D
28,473
600
720
SWGM0720D
26,993
SWGG0720D
33,591
SWGW0720D
33,797
(1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - MTE SINE WAVE FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
MTE SINE WAVE FILTERS
SINE WAVE FILTERS
LIST PRICES
Designed to provide a pure sine wave output when driven from a VFD
Select filters based on the current rating of the motor
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
600V
SINE WAVE FILTERS 600VAC 60Hz
OPEN CHASSIS
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
1.5
2
SWAP0002E
1,256
SWAGA0002E
1,497
SWAWA0002E
2,194
2
3
SWAP0003E
1,386
SWAGA0003E
1,627
SWAWA0003E
2,324
3
5
SWAP0005E
1,677
SWAGA0005E
1,924
SWAWA0005E
2,359
5
7
SWAP0007E
1,808
SWAGA0007E
2,068
SWAWA0007E
2,502
7.5
9
SWAP0009E
1,833
SWAGA0009E
2,094
SWAWA0009E
2,523
10
12
SWAP0012E
1,860
SWAGA0012E
2,124
SWAWA0012E
2,570
15
17
SWAP0017E
2,033
SWAGB0017E
2,404
SWAWB0017E
2,823
20
22
SWAP0022E
2,310
SWAGB0022E
2,515
SWAWB0022E
2,972
25
27
SWAP0027E
2,387
SWAGB0027E
2,603
SWAWB0027E
3,114
30
35
SWAP0035E
2,671
SWAGB0035E
2,878
SWAWB0035E
3,212
40
45
SWAP0045E
2,686
SWAGB0045E
2,886
SWAWB0045E
3,275
50
55
SWAP0055E
3,255
SWAGC0055E
4,150
SWAWB0055E
4,463
60
65
SWAP0065E
3,611
SWAGC0065E
4,366
SWAWB0065E
4,679
75
80
SWAP0080E
4,805
SWAGC0080E
5,847
SWAWC0080E
6,159
100
110
SWAP0110E
5,669
SWAGC0110E
6,825
SWAWC0110E
7,114
125
130
SWAP0130E
6,477
SWAGC0130E
10,235
SWAWC0130E
10,532
150
160
SWAP0160E
6,853
SWAGC0160E
10,897
SWAWC0160E
11,194
200
200
SWAP0200E
7,799
SWAGD0200E
11,733
SWAWD0200E
12,031
250
250
SWAP0250E
8,365
SWAGD0250E
13,342
SWAWD0250E
13,342
300
305
SWAP0305E
12,643
SWAGD0305E
17,224
SWAWD0305E
16,204
350
365
SWAP0365E
13,904
SWAGD0365E
17,483
SWAWD0365E
17,285
400
415
SWAP0415E
19,481
SWAGD0415E
23,041
SWAWD0415E
23,560
450-500
515
SWAP0515E
21,865
SWAGD0515E
27,871
SWAWD0515E
28,355
600
600
SWAP0600E
28,192
SWAGE0600E
33,666
SWAWE0600E
34,047
700
720
SWAP0720E
33,199
SWAGE0720E
39,203
SWAWE0720E
39,584
NOTE:
(1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
(2) Prices subject to change without notice.
(3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - MTE SINE WAVE FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 51
MTE MATRIX
MODEL:
MTE MATRIX FILTERS
DESCRIPTION: MTE Matrix Filters meet the most stringent IEEE-519
requirements (5% THID) of removing current distortion on
virtually any kind of six pulse rectifier.
APPLICATIONS
• Any VFD Loads
• Induction Heating Equipment
• Fans and Pumps
• Water Treatment Facilities
• Hospitals and Critical Applications
FEATURES
• 6 to 786 Amp Current Range
• 480 & 600V, 50/60Hz, 3-Phase
• Capacitor Options & More
• Epoxy Impregnated
• High Saturation Current Rating
• Performance Guarantee to Meet IEEE 519
• Generator Compatible
• Available in Open Style, NEMA 1 or NEMA 3R
• No System Analysis Required to Select and Apply Matrix Filters
• cUL and CE Approved
C - 52
FEATURES
Control Products - MTE MATRIX FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
Effective 02-11-16
Supercedes All Previous
MTE MATRIX
LIST PRICES
MTE MATRIX FILTERS
For use with 6 pulse Variable Frequency Drives to mitigate
harmonics to less than 5% THID at full load current
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
480V
MTE SERIES D MATRIX HARMONIC FILTERS 480VAC 60Hz
OPEN CHASSIS
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
5
8
MAPP0008D
2,425
MAPG0008D
3,975
MAPW0008D
4,470
10
14
MAPP0014D
2,830
MAPG0014D
4,350
MAPW0014D
4,840
15
21
MAPP0021D
3,295
MAPG0021D
4,895
MAPW0021D
5,400
20
27
MAPP0027D
3,710
MAPG0027D
5,360
MAPW0027D
5,865
25
34
MAPP0034D
4,120
MAPG0034D
5,815
MAPW0034D
6,335
30
44
MAPP0044D
4,535
MAPG0044D
6,160
MAPW0044D
6,800
40
52
MAPP0052D
5,255
MAPG0052D
7,060
MAPW0052D
7,585
50
66
MAPP0066D
6,065
MAPG0066D
7,965
MAPW0066D
8,500
60
83
MAPP0083D
6,870
MAPG0083D
8,870
MAPW0083D
9,415
75
103
MAPP0103D
7,680
MAPG0103D
9,820
MAPW0103D
10,385
100
128
MAPP0128D
10,105
MAPG0128D
12,485
MAPW0128D
13,075
125
165
MAPP0165D
11,225
MAPG0165D
13,840
MAPW0165D
14,465
150
208
MAPP0208D
12,125
MAPG0208D
14,980
MAPW0208D
15,630
200
240
MAPP0240D
12,720
MAPG0240D
16,050
MAPW0240D
16,760
250
320
MAPP0320D
18,060
MAPG0320D
23,765
MAPW0320D
24,480
300
403
MAPP0403D
21,000
MAPG0403D
26,710
MAPW0403D
27,420
400
482
MAPP0482D
24,335
MAPG0482D
30,045
MAPW0482D
30,755
500
636
MAPP0636D
32,835
MAPG0636D
39,775
MAPW0636D
40,865
600
786
MAPP0786D
38,780
MAPG0786D
46,805
MAPW0786D
48,015
700
850
MAPP0850D
44,725
MAPG0850D
52,805
MAPW0850D
55,165
900
1000
MAPP1000D
56,610
MAPG1000D
66,595
MAPW1000D
68,140
1000
1200
MAPP1200D
62,555
MAPG1200D
73,490
MAPW1200D
75,155
NOTE:
(1)
(2)
(3)
(4)
Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
Prices subject to change without notice.
F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Capacitor Contactor (-002) option is available, please contact your TWMI representative for a price and delivery.
Control Products - MTE MATRIX FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 53
MTE MATRIX
LIST PRICES
MTE MATRIX FILTERS
For use with 6 pulse Variable Frequency Drives to mitigate
harmonics to less than 5% THID at full load current
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
600V
MTE SERIES D MATRIX HARMONIC FILTERS 600VAC 60Hz
OPEN CHASSIS
NOTE:
C - 54
NEMA 1
NEMA 3R
HP
AMPS
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
CATALOGUE
NUMBER
LIST
PRICE
5
6
MAPP0006E
2,660
MAPG0006E
4,165
MAPW0006E
4,655
10
11
MAPP0011E
3,070
MAPG0011E
4,680
MAPW0011E
5,075
15
21
MAPP0021E
3,610
MAPG0021E
5,210
MAPW0021E
5,715
25
27
MAPP0027E
4,275
MAPG0027E
5,970
MAPW0027E
6,490
30
34
MAPP0034E
4,585
MAPG0034E
6,330
MAPW0034E
6,850
40
44
MAPP0044E
5,600
MAPG0044E
7,300
MAPW0044E
7,975
50
52
MAPP0052E
6,300
MAPG0052E
8,205
MAPW0052E
8,740
60
66
MAPP0066E
7,110
MAPG0066E
9,105
MAPW0066E
9,655
75
83
MAPP0083E
8,320
MAPG0083E
10,460
MAPW0083E
11,025
100
103
MAPP0103E
10,345
MAPG0103E
12,720
MAPW0103E
13,315
125
128
MAPP0128E
11,430
MAPG0128E
14,045
MAPW0128E
14,665
150
165
MAPP0165E
12,855
MAPG0165E
15,705
MAPW0165E
16,360
200
208
MAPP0208E
14,765
MAPG0208E
18,090
MAPW0208E
18,805
250
240
MAPP0240E
18,000
MAPG0240E
21,805
MAPW0240E
24,420
300
320
MAPP0320E
21,415
MAPG0320E
25,695
MAPW0320E
27,830
400
403
MAPP0403E
26,305
MAPG0403E
31,535
MAPW0403E
32,725
500
482
MAPP0482E
32,825
MAPG0482E
39,005
MAPW0482E
40,075
600
636
MAPP0636E
38,530
MAPG0636E
46,550
MAPW0636E
47,760
800
786
MAPP0786E
48,440
MAPG0786E
58,595
MAPW0786E
60,045
(1)
(2)
(3)
(4)
Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability.
Prices subject to change without notice.
F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Capacitor Contactor (-002) option is available, please contact your TWMI representative for a price and delivery.
Control Products - MTE MATRIX FILTERS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
SG2
PROGRAMMABLE
LOGIC RELAYS
MODEL:
SG2 PROGRAMMABLE LOGIC RELAYS
FEATURES
DESCRIPTION: SG2 PLR offers a solid alternative to using mechanical
relays and timers / OP10 HMI Can be used with SG2 as well
as TECO VFD’s.
Effective 02-11-16
Supercedes All Previous
APPLICATIONS
• Panel Upgrades
• OEM Favorite
FEATURES
• SG2 Available in Blind or with HMI Built-In
• 24VDC or 85 to 240Vac
• Built-In Modbus Available on Specific Models
• FREE Software Available
• Expansion Modules Available
• Software Allows Ladder Logic Programming or Function Block Programming
• Offline Simultation
• Online Monitoring
• HMI Can Be Used with SG2 and TECO VFD's
• HMI Offers 4.3 Monochrome Graphic Panel 192 x 64 Pixels
• UL, cUL, CE Approved
Control Products - SG2 PROGRAMMABLE LOGIC RELAYS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 55
SG2
PROGRAMMABLE
LOGIC RELAYS
LIST PRICES
SG2 PROGRAMMABLE LOGIC RELAYS
Simple yet powerful, dependable yet affordable
The SG2 PLR Includes the needed features at the industry’s lowest price
Effective 02-11-16
Supercedes All Previous
VOLTAGE:
24V to 240V
SG2 PROGRAMMABLE LOGIC RELAYS
DISCRETE / DIGITAL
ANALOG
COMMS
DISPLAY
KEYPAD
MAX I/O
LIST
PRICE
0
Prog RS232
4 x 12 Char.
8 key
34
175
2
0
Prog RS232
4 x 12 Char.
8 key
36
155
2
0
Prog RS232
-
-
36
132
CATALOGUE
NUMBER
CONTROL
POWER
INPUTS
OUTPUTS
INPUTS
OUTPUTS
SG2-10HR-A
85-240 VAC
6
4
0
SG2-12HR-D
24 VDC
6
4
SG2-12KR-D
24 VDC
6
4
SG2-20HR-A
85-240 VAC
12
8
0
0
Prog RS232
4 x 12 Char.
8 key
44
252
SG2-20VR-D
24 VDC
8+4
8
4
0
RS-232/RS-485
4 x 12 Char.
8 key
44
245
SG2-8ER-D
24 VDC
4
4
0
0
N/A
N/A
N/A
N/A
100
SG2-8ER-A
85-240 VAC
4
4
0
0
N/A
N/A
N/A
N/A
122
SG2-4AI
24 VDC
0
0
4
0
N/A
N/A
N/A
N/A
195
SG2-2AO
24 VDC
0
0
0
2
N/A
N/A
N/A
N/A
195
SG2-4PT
24 VDC
0
0
4-(PT100)
0
N/A
N/A
N/A
N/A
245
SG2-EN01
24 VDC
0
0
0
0
ETHERNET/232
N/A
N/A
N/A
735
SG2-MODBUS
24VDC
0
0
0
0
RS-485
N/A
N/A
N/A
245
SG2 OPTIONAL HARDWARE
CATALOGUE NUMBER
DESCRIPTION
LIST PRICE
NOTE:
C - 56
SG2-PL01
SG2 Programming Cable, RS-232 to SG2-Programming Connector
40
SG2-ULINK
SG2 Programming Cable, USB to SG2-Programming Connector
82
SG2-SW-EDM
SG2 Programming software on CD ROM. Also available as free download from Internet.
0
SG2-PM05
SG2 Memory Cartridge.
20
SG2-10PS-24
Power Supply 24 Volt Output
100
OP10
HMI Screen RS232, RS485 MODBUS
252
OP10-PL01
Programming cable for OP10 HMI
25
(1) Prices subject to change without notice.
(2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.
Control Products - SG2 PROGRAMMABLE LOGIC RELAYS
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
CUSTOMER SERVICE
FIELD SERVICE AND START-UP ASSISTANCE
Effective 02-11-16
Supercedes All Previous
ACTIVITY
RATE (CND $)
DESCRIPTION
Basic Rate
$120.00/Hr
Up to 8 hours a day, Monday - Friday, 7:00am - 6:00pm
Standard Overtime:
Extended weekdays and Saturdays.
$180.00/Hr
Weekday overtime and all hours prior to 7:00am or beyond
6:00pm and all Saturday time. Total time not to exceed 12
hours in any 24-hour period.
Special Overtime:
Sundays, Holidays and in excess of
8 hours on Saturdays.
$240.00/Hr
All Sunday and Holiday work and all time in excess of 8 hours
on Saturdays. Total time not to exceed 12 hours in any 24hour period.
$1.05/KM
Auto mileage charges cover the use of company or personal
vehicles. Driving time is included in actual total time en-route
from office to job site area.
Cost plus 15%
Transportation expense at cost based on round trip fares for
personnel and equipment. Time involves actual total time enroute from office to the job site area.
Same as
Service Time
Rate
Holdover and standby time (waiting or on call) is considered
service time and rendered at prevailing service rates. This
rate will be charged to retain a technician in the service job
site area in lieu of his/her incurring additional expense by
returning to his/her headquarters.
Auto travel (round trip)
Transportation and Living
Expenses
Hold over and Standby time
If an authorized TECO-Westinghouse service representative performs a certified Controls start-up per the above field service rates, the 12 month
standard warranty will be extended to 24 months from date of start-up, or 27 months from date of purchase, whichever is less.
NOTE:
(1) Prices subject to change without notice.
(2) Travel time will be rendered the same as Service Time Rates.
(3) Parts and materials supplied in connection with Field Service work will be priced in accordance with the Company’s published Conditions of
Sale and pricing policy.
(4) Any Equipment Rental in connection with Field Service work will be billed at cost.
(5) Any duties, visas or custom charges in connection with Field Service work will be billed at cost.
(6) Any credit for warranty materials will be identified on the TWMI Service Report Form, which should be acknowledged by the customer’s
signature each day.
(7) All rates are subject to appropriate taxes.
Control Products - FIELD SERVICE AND START-UP ASSISTANCE
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
C - 57
C - 58
Blank
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
ENCLOSURES
There are two broad enclosure classifications:
OPEN and TOTALLY ENCLOSED. Each is divided into a number of
specific types. The primary types are as follows:
OPEN
TOTALLY ENCLOSED
Drip-proof
Non-ventilated
Fan-cooled
Explosion-proof
Externally ventilated
Heat exchanger
Splashproof
Weather-protected
Only those most frequently used will be discussed here.
Drip-proof Enclosures
The NEMA definition for this type of enclosure is “a drip-proof
machine is an open machine in which the ventilating openings
are so constructed that successful operation is not interfered with
when drops of liquid or solid particles strike or enter the enclosure
at any angle from 0 to 15 degrees downward from the vertical.” In
the drip-proof motor, the cooling air is drawn into the motor from
the outside and comes into direct contact with the winding, rotor,
and all other internal parts of the motor. Therefore, the internal
motor parts must be able to withstand any contaminants present
in the atmosphere in which the motor is located.
The open drip-proof motor is designed to be an economical
choice for most indoor applications where reasonably clean
environments exist. As the name implies, this motor is adequately
protected so that water dripping from overhead will not be drawn
into the motor. The open drip-proof (ODP) should not, however,
be used on applications where washdown with hoses is apt to
occur or when driving rain, fog or snow will occur.
Totally Enclosed
A totally enclosed motor is designed to prevent the free
exchange of air between the inside and the outside of the motor
housing, but not sufficiently tight to be termed airtight. When
the motor is equipped with an integral fan that blows air over
the exterior surface of the frame, the motor is classed as being
TOTALLY ENCLOSED FAN-COOLED (TEFC). Without an externalcooling fan, the motor is classed as being TOTALLY ENCLOSED
NON-VENTILATED (TENV).
Breather / Drains
To prevent against damaging amounts of water, every standard
TEFC motor is supplied with one or two drain holes in the lowest
point of the motor frame. This hole can easily be closed with a
tapped pipe plug. Advantage Plus and Optim® TEXP motors are
supplied with automatic Breather/Drains as standard equipment.
Such breathers allow the motor to drain any condensed moisture
without allowing contaminants to be sucked into the motor
during operation. Breather/Drains can be installed in any TECOWestinghouse motor on frame sizes 140T or larger. Breather
drains can also be installed or relocated to accommodate vertical
mounting on any TECO-Westinghouse motor with the exception
of Optim® TEXP due to restrictions with the certifications.
Space Heaters
Space heaters can also be installed inside the motor enclosure to
heat the inside air and maintain an internal temperature above
the ambient dew point. This assures that cooling air will not
condense and produce moisture inside the motor. Space heaters
available for motors are the wrap-around type. Space heaters are
rated for operation on 120V or 240V, 60 Hz, single phase power
and are installed in the stator winding end-turns. Space heater
leads can be terminated in the main conduit box or auxiliary box
located off the main conduit box.
Rotating Shaft Seal
Special protection is provided at the point where the motor
shaft passes through the bearing housing in the form of an
external flinger. This flinger keeps water, dust and other foreign
matter out of the motor that might enter the motor along the
shaft. All motors are furnished with a rotating neoprene flinger
or machined metal labyrinth seal. INPRO/SEALS™ are optional
for Advantage Plus Motors. TEXP motors are furnished with shaft
seals approved for hazardous locations as defined by CSA.
Sealed Leads
Additional protection against moisture is provided by a neoprene
seal through which each motor lead wire is brought out of the
motor frame to the terminal box. This is a standard feature for all
TECO-Westinghouse motors.
Totally Enclosed Fan Cooled
Cooling of TEFC motors takes place due to a continuous flow of
air over the outside surface of the motor. The motor’s surface
is usually ribbed to obtain additional surface area for heat
dissipation. The airflow is produced by a fan that is mounted on
the shaft at the front of the motor. In order to provide power
to drive this fan, the motor shaft is extended through the front
of the motor and a suitable fan is mounted on this stub shaft.
For protection and direction control of the airflow, a fan cover
is installed over the fan. Fan covers are either fabricated with
pressed steel or for severe duty applications constructed of
cast-iron.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D-1
INDUCTION MOTOR REFERENCE GUIDE
ENCLOSURES
Explosion Proof Design
Externally Ventilated Motors
The Standard explosion proof motor is to be used in
all hazardous atmospheres listed under the following
classifications:
Occasionally, an external cooling system is used. This is
necessary in case the motor’s own fan will not provide sufficient
cooling; such as on certain duty-cycle applications, planer
drives, certain slow speed motors, etc. In other cases, the motor
may be located in an extremely dirty atmosphere where it is
desirable to connect the motor’s air intake to a source of clean
air by means of a duct. In either case, the air discharge can
either be into the room directly from the motor, or it can be
carried away from the motor through a pipe.
Class I, Group D, gasoline, naptha, alcohols, acetone, lacquer
solvent vapors and natural gas
Class II, Group E, metal dust including magnesium and
aluminum or their commercial alloys
Class II, Group F, carbon black, coal or coke dust
Class II, Group G, flour, starch or grain dust
Note: Under Class 1 only, there are two divisions which allow
some latitude on motor selection:
Generally, Class I, Division 1, locations are those in which the
atmosphere is or may be hazardous under normal operating
conditions. Included are the locations which can become
hazardous during normal maintenance. An explosion-proof
motor is mandatory for Division 1 locations.
Class I, Division 2, refers to locations where the atmosphere may
become hazardous only under abnormal or unusual conditions
(breaking of a pipe, for example). In general, motors in standard
enclosures can be installed in Division 2 locations if the motor
has no normally sparking parts. Thus, open or standard totally
enclosed squirrel cage motors are acceptable, but motors with
open slip rings or commutators (wound rotor, synchronous or
DC) are not allowed unless the commutator or slip rings are in
an explosion-proof enclosure. Optim® TEFC and Advantage Plus
motors are approved for Class I, Division 2, Group B, C and D
environments.
Explosion proof motors bear a label that is certified by
Underwriters’ Laboratories and CSA. This label can be applied
only by a motor manufacturer, such as TECO-Westinghouse,
whose facilities are under the constant supervision of
Underwriters’ Laboratories and CSA. Once a motor is
disassembled in the field, the label no longer applies, unless
the work is performed in a plant approved by Underwriters’
Laboratories or CSA.
Motors with motor-mounted, separately driven blowers are
usually called “force ventilated.”
Motors ventilated from an external source are called “pipe
ventilated.” In this case, the air pressure can be supplied by an
external blower, or an oversize fan can be used in the motor
itself to draw air through the intake duct and force it through
the motor.
Enclosures Summarized
Drip-proof, for installation:
In non-hazardous atmospheres not containing abrasive or
conducting dusts, high concentrations of chemical or oil
vapors and/or where hosing down or severe splashing is not
encountered.
Totally Enclosed Fan Cooled, for installation:
In non-hazardous atmospheres containing abrasive or
conducting dusts, high concentrations of chemical or oil vapors
and/or where hosing down or severe splashing is encountered.
Totally Enclosed Explosion Proof, for installation:
In hazardous atmospheres as defined by CANADIAN
ELECTRICAL CODE (CEC) section 18.
A Word of Caution
It is the user’s responsibility to specify the atmosphere in the
plant in which motors are to be applied. The user normally
receives a classification from their insurance company as to
the type of motor enclosure to be used where a hazardous
atmosphere exists. If the user asks for recommendations, ask
him to get a classification from his insurance company.
D-2
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
ENCLOSURES
MECHANICAL CONSIDERATIONS
Frame Size
Motor Mounting
Motor frame dimensions have been standardized with a
uniform frame size numbering system developed by NEMA.
The current standardized frames for integral horsepower
induction motors range from 143T to 449T. These standards
cover most motors in the range of 1 through 250 Horsepower.
Installation Requirements
The factors to consider in connection with the mounting
requirements of the specific installation are:
First, how is the motor to be mounted?
The numbers used to designate frame sizes have specific
meanings based on the physical size of the motor. The first two
digits are related to the motor shaft height and the remaining
digit or digits relate to the length of the motor.
There are two main categories:
1)
2)
The shaft height of horizontal motors can be calculated by
dividing the first two digits of frame size by 4.
Second, in what position is the motor to be mounted?
For example, a 256T frame motor would have a shaft height
(“D”) dimension of 25/4 = 6.25 inches. Similarly, a 444T frame
motor would have a shaft height of 44/4 = 11 inches.
The possibilities include shaft:
Horizontal
Vertical
At an angle
The third digit of the frame size is related to the length of the
motor. There is no general rule of thumb that can be easily
applied to determine the length of the motor.
Third, is other equipment to be mounted on the motor?
It is important to note that when standard foot mounted motors
have frame sizes that differ only in the third digit, the shaft
diameters, shaft lengths and distance from the end of the shaft
to the bolt holes in the feet on the shaft end of the motor will
be the same. It is the motor length or distance from the drive
end bolt-down holes to the “front” bolt-down holes that will
vary.
Frame Suffix Letters
When a motor is provided with special mounting dimensions,
flanges or special shaft features, this is indicated by adding a
suffix letter to its frame number.
FOR EXAMPLE:
A 254TS frame motor indicates that the motor has a shaft extension length and diameter different from that of a 254T frame
motor.
The standard suffix letters and their meanings are as follows:
C .................... “C” flange mounting
D .................... “D” flange mounting
E ..................... Special shaft for elevator motors
K..................... (prefix on DC motors) – longer than standard
overall length, but still has standard mounting
dimensions
P & PH.......... Vertical P or PH flange mounting
T ..................... Standard shaft for belted service
TS .................. Standard short shaft for coupled service
V .................... Vertical mounting
X .................... Wound rotor crane and hoist motors with double
shaft extension – sometimes used as a prefix to
denote a very special frame such as explosion-proof
Y..................... Special mounting dimensions
Z .................... Special shaft extension
Some type of base that will accommodate standard
motor feet.
Installation in such a way that a special mounting
flange is required on the motor.
This may include:
Pumps
Brakes
Gears
Zero-speed switches
Tachometers
Fourth, where is the conduit box to be located on the motor
frame to best meet the needs of the installation’s wiring
arrangement?
Two points must be checked:
1)
2)
The position of the conduit box on the motor frame.
The position of the conduit opening.
Conduit Box Location
The standard location for the conduit box is on the right-hand
side when facing the “front” of the motor.
Definitions of “Front”
There is still some confusion regarding which end of a motor
is its “front.” Since this is a frequently used term, it is important
that everyone is consistent.
NEMA defines the “front” of a motor as the end opposite the
shaft extension. (“When a motor has a flange, the flanged end
is always considered to be the “rear”).
The reason for this is that most motors are mounted with the
shaft extension more or less hidden from view. Thus, the “front”
is the end you normally see.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D-3
INDUCTION MOTOR REFERENCE GUIDE
MECHANICAL CONSIDERATIONS
Foot Mounting
P-Flange
Most of the mounting problems encountered can be solved
with one of the assembly combinations of a standard foot
mounted motor. A thorough understanding of the basic
components and how they can be positioned will result in a
greater use of standard motors.
The primary application of this flange is on such equipment as
pumps and agitators where the motor is usually mounted in a
vertical position on top of the equipment.
The Frame includes the mounting feet and forms the
foundation for the complete assembly. It can be positioned
with the feet in any plane . . . top, bottom or side.
When a horizontal motor is to be mounted in the vertical
position special considerations must be made to ensure proper
operation and motor life. The considerations are dependent on
the motor shaft orientation.
Vertical Mounting
The Conduit Box can be located on either side of the frame.
1. Shaft Down:
F-1 = Conduit box on right-hand side of frame when facing
“front” of motor.
F-2 = Conduit box on left-hand side of frame when facing
“front” of motor.
-
The conduit opening can be placed in any one of four positions
by rotating the conduit box on its axis in 90º steps.
-
Drain holes/breathers must be relocated to the lowest
part of the motor and the original holes plugged. (Except
TEXP Motors)
Drip cover should be installed for outdoor applications,
or if motor is exposed to overhead/spraying moisture
*NDE bearing must be locked with a shaft locknut
5000 frames and larger.
C-Flange motors to be mounted on a pump must have
the DE BRG locked. The only axial movement will be the
internal clearance of the bearing.
A standard motor can be adapted to any of these standard
mounting methods. TECO-Westinghouse will provide motors
configured as ordered, either F-1 or F-2. Price adders may apply.
-
Angle Mounting
* Motor shall not be subject to additional axial loading
from driven equipment.
Where the application requires the shaft to be at an angle to
the horizontal, special attention must be paid to the motor
bearings.
2. Shaft Up:
-
Grease-lubricated ball bearings are suitable for operation at
any angle. However, motors equipped with sleeve bearings or
slipring induction motors are limited to angle mounting that
does not exceed 10º from the horizontal.
Flange Mounting
There are three basic types of flange mountings; each are
designed to meet different installation requirements.
C-Flange
This type of flange is used with close-coupled pumps and
similar applications where the mounting holes in the flange
are threaded to receive bolts from the pump. Normally the “C”
flange is used where a pump or similar item is to be overhung
on the motor, which then must have feet.
D-Flange
When the motor is to be built-in as part of the machine,
such as on machine tools, the “D” flange is usually selected.
The mounting holes in this flange are not threaded. Bolts
protrude through the flange from motor side. Normally, “D”
flange motors are supplied without feet, since the “D” flange
is generally used to mount the motor on the driven machine.
The motor is lined up with the driven machine by tightening
the bolts to press the machined surface and ring of the flange
against corresponding surfaces.
D-4
-
Drain holes/breathers must be relocated to the lowest
part of the motor and the original holes plugged. (Except
TEXP Motors)
If an inpro/seal is to be used it should be suitable for
vertical use with no expulsion port.
Coupling Methods
Direct Drives
Statistics show that only about one out of five machines operate
at the same speed as its driving motor. When the motor is
directly connected to the load, the application considerations
are different than when some intermediate means is used to
increase or decrease the speed.
Direct coupling of the motor to the load is practical if the load
is to run at a standard motor speed. For these applications,
specify “short shaft for coupled service.”
Belted Drives
Gear-chain-drives and belt-drives are most commonly used to
obtain speed reduction between motor and driven machine. In
applying these drives to standard motors, two factors must be
checked:
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
1.
2.
Effect on motor bearings.
Effect on motor shaft.
INDUCTION MOTOR REFERENCE GUIDE
MECHANICAL CONSIDERATIONS
Each of these drives will impose some strain on the bearings
and shaft of the motor. The amount of strain in each case
establishes the practical maximum values of horsepower and
speed. The maximum values shown in Figure 7 have been
established by NEMA to assure good bearing life and guard
against excessive shaft stress in the application of V-belt drives
to NEMA standardized frames.
Motor
Frame
Synchronous
Speed, RPM
Max.
HP
256T
3600
25
445T
1800
200
445T
1200
125
445T
900
100
Figure 7. Maximum Horsepower V-Belt Drives Recommended by NEMA
for NEMA Standardized Frames
Non-Standard Belt Applications
A user may want to use a belt drive on a motor outside of the
sizes listed in Figure 7. In such a situation, send all available
information on the application to TECO-Westinghouse. This
must include the following information:
1. Belt type (A, B, C, D, or E) and size
2. Number of belts
3. Sheave dimensions (pitch diameter, also face width
and weight)
4. Direction of belt pull (whether up, down, or some
other angle)
5. Centre Distance
There are several things that TWMI can do depending on the
application:
1. In some cases, the standard motor may be suitable.
2. Engineers may be able to suggest some slight change in
user’s drive details to permit the use of a standard motor.
Belt Tension
All belt drives should include a means for adjusting belt tension.
This may be a sliding base, slide rails or other device. The
natural tendency of most operators is to run the belts too tight
regardless of whether “V” belts or flat belts are being used. A
good rule to remember is this – a belt that never slips is usually
too tight. A properly applied belt will always slip slightly when
starting under load. Tight belts shorten bearing life, and may
cause vibration and shaft breakage.
Under certain conditions of excessive shaft stress, the shaft may
rupture before the bearing fails.
This type of failure is usually encountered when a motor is
applied to a belted load which exceeds the NEMA standard for
its particular rating (See figure 7).
Bearings
Ball Bearings
All anti-friction bearings are rated on the basis of the fatigue life
of the material. The “life” of a bearing is defined as the number
of revolutions completed (or hours at some given speed) before
the first evidence of fatigue develops.
This point is difficult to predict for an individual bearing.
Therefore, statistical distribution is employed to predict bearing
life on the basis of the performance of a group of bearings.
The “minimum” life of a group of identical ball bearings is
defined as the number of revolutions (or hours) that 90% of the
group of bearings will complete or exceed before the first
evidence of fatigue develops. The “average” life is 5 times the
minimum life.
Both of these factors are based on bearings running at their
rated load. For loads above or below this point, bearing life
varies inversely with the cube of the load:
Loada
Loadb
3
=
Lifeb
Lifea
Failure of ball bearings may be caused by:
1. Rough races caused by dirt …one reason why doubleshielded sealed bearings are used is to minimize the
possibility of introducing dirt into the bearings.
2. Metal flaking or cracking from balls or races … caused by
overloading.
3. Worn or broken retainer … caused by faulty lubrication or
misalignment. We provide adequate lubrication and guard
against misalignment by properly machining the parts.
4. Bearing jammed by hardened grease … result of high
temperature or contamination.
Using Speed-Torque Curves
A great deal can be learned about torque from speed-torque
curves. A typical speed-torque for an AC squirrel-cage motor is
shown on the following page. Such a curve tells what kind of
jobs a specific motor can handle.
This speed-torque curve is typical for a whole family of motors,
but for this discussion assume it is for a 10HP, 1200 RPM AC
squirrel-cage motor. Full-load torque is listed as 45 lb-ft (1).
In analyzing the solid-line motor curve, start at (2). This is the
starting torque point which is one of the critical selection
factors. The value is 150% of full-load torque, which of course,
is 67-1/2 lb-ft for this specific motor.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D-5
INDUCTION MOTOR REFERENCE GUIDE
MECHANICAL CONSIDERATIONS
Now, moving up the curve, you see that the torque drops off a
bit as the motor picks up speed, until about 20% synchronous
speed is reached. At this point, the torque starts to increase and
continues doing so until about 75% speed is reached (3). The
motor has now reached the maximum, or breakdown, torque.
The abscissa shows this point to be at 200% of full-load torque,
which, when converted, equals 90 lb-ft. The speed is 900 RPM.
It is fairly obvious that as long as the torque curve of the driven
machine stays to the left of the motor speed-torque curve up
to the full-load point, the motor will be able to handle the job.
However, should any portion of the driven machine torque
curve fall to the right of the motor speed-torque curve, then a
different motor must be selected.
FOR EXAMPLE:
This is another critical selection factor, particularly where
fluctuating loads are involved. No point in the duty cycle can
exceed this torque value. If it does, it will stall the motor.
From here on, as the motor approaches synchronous speed, the
torque decreases. At (4) the motor has reached full-load torque
and is operating at full-load speed which is 1160 RPM. As would
be expected, it is at this point that the rated horsepower is
established.
The difference between the synchronous speed of the stator’s
rotating magnetic field and the speed of the rotor is termed
“slip.” With this motor, the slip is 40 RPM, or 3-1/3 percent.
The dotted line, labeled (5), is the speed-torque curve for a
loaded ball mill. The complete curve falls within the operating
area of the motor.
The dash line, labeled (6), is the speed-torque curve for a loaded
rolling mill. Here you see that the required starting torque falls
beyond the capacity of this motor. Therefore, a different motor
will have to be used.
The motor speed-torque curve shown here is that of a NEMA
design B motor. As you know, there is a number of other NEMA
designs for polyphase squirrel-cage motors, ... namely: A, C, D
and F. Each design develops a different set of characteristics.
Each design is intended for a different use.
SPEED-TORQUE CURVE - NEMA B
D-6
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
MECHANICAL CONSIDERATIONS
Environment
Shock and Vibration mechanically abuse the complete motor
causing breakage of mounting feet, frames, shafts and brackets,
fatigue terminal connections, damage bearings and produce
mechanical wear on insulation.
The Environment Check List itemizes the problem areas. If the
motor is exposed to any of these conditions, provisions must be
made to protect the complete motor or its parts.
Corrosive Agents eat away at insulation and exposed metal
parts (air-gap surfaces, bearings, and shaft)… eventually cause
malfunction of these parts.
An understanding of the reasons for examining each of
these problems will help determine which type of insulation
is needed.
Abrasive Agents erode protective coatings as well as exposed
surfaces, causing breakdown of insulation, score critical bearing
surfaces.
Environment Check List
Ambient Temperature
Higher than 40ºC (104º F)
Lower than -40ºC (-40º F)
Altitude
Above 3300 feet above sea level
Mechanical Abuse
Shock
Vibration
Contaminants
Corrosive Agents
Chemicals
Abrasive Agents
Dust
Filings
Sand
Blanketing Agents
Dust
Lint
Snow
Moisture
High humidity
Water
Form
Solid
Liquid
Gas
Method of Movement
Suspended in air
Falling from above
Force directed
Blanketing Agents deposit unwanted coatings on critical parts,
clog air vents and passages and reduce heat dissipation. This
points up the need for frequent inspection when the motor is
located in contaminated atmospheres because current overload
protection or ammeters on the control panel do not detect
overheating of the motor caused by obstructed ventilation.
Moisture collects on critical parts, causes shorting of electrical
components and corrodes exposed metal parts.
High Ambient Temperature
Since total temperature at the hottest spot and the insulation
temperature capability are the governing factors, there are two
approaches that can be taken.
1. Use a higher class of insulation i.e. Class H in place of Class F.
This would allow an extra 25ºC to be utilized to offset the
elevated ambient temperature. For example, a motor
designed for a Class F insulation system but built with
Class H insulation could theoretically operate satisfactorily
in an ambient temperature of 65ºC instead of 40ºC. Consult
your local TWMI representative for individual evaluation.
PLEASE NOTE:
At elevated ambient temperatures, the type of bearings and the
bearing lubricant would also have to be carefully analyzed.
2. Utilize the same insulation system but increase the motor
frame size. This approach will lower the motors operating
temperature rise thus making part of the temperature rise
capability available to withstand the elevated ambient
temperature. This is equivalent to oversizing the motor
horsepower.
High Ambient Temperature primarily affects the insulation. It
causes deterioration and accelerated aging. It also can reduce
the viscosity of the greases in the bearings to the point where
its lubrication value is impaired.
Low Ambient Temperature primarily affects lubrication. It can
increase the viscosity of the grease in the bearings to the point
where its lubrication value is impaired, especially during startup.
Extreme low temperatures can cause materials to become
brittle and prone to failure such as shaft breaks or cracked stator
housings.
High Altitude where the thinner air has less cooling ability,
causes excessive temperature rise in the motor.
Low Ambient Temperature
1. -41ºC to -50ºC (-41ºF to -58º F). Low temperature grease
rated to minimum -50ºC must be used to ensure adequate
lubrication during startup and operation. Space Heaters
are strongly recommended, especially for interment duty
applications.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D-7
INDUCTION MOTOR REFERENCE GUIDE
MECHANICAL CONSIDERATIONS
2. Below -50ºC (-58º F). Special consideration to the frame and
shaft material must be made. Ductile cast iron will be used
to increase tensile and yield strength, 4140 steel will be
used for the shaft material. Appropriately rated low
temperature grease must be used to ensure adequate
lubrication during startup and operation. Space Heaters
are strongly recommended, especially for interment
duty applications. Consult your local TWMI representative
for individual evaluation.
Other Reasons for Using Higher Insulation Classes
Occasionally it is desirable to use a higher class of insulation in
order to put more horsepower into a particular frame size or to
give the motor more capability to safely accelerate high inertia
loads.
High Elevation
An additional factor that affects the motor’s ability to dissipate
heat is the density of the surrounding air. With higher air
density, more heat can be transferred. Generally the density of
air at a specific location is very constant, but air density does
vary with elevation; thus, when motors are installed at locations
where the elevation is substantially above sea level,
consideration must be given to this factor.
Standard motors will operate successfully within their
normal temperature rating at elevations up to 1000 meters
(3300 ft) above sea level. When motors are to be operated
above this altitude, the motor design should be checked for its
suitability at the required elevation. Contact your local TWMI
Representative for evaluation. When required, motor design can
be modified to make them suitable for high elevation operation.
ALTITUDE
(FEET)
HP
DERATING
FACTOR
3,300 – 5,000
0.97
5,001 – 6,600
0.94
6,601 – 8,300
0.90
8,301 – 9,900
0.86
9,901 – 11,500
0.82
MOTOR DESIGNS
Horsepower Formula
There are four conditions that define a motor’s performance
characteristics:
Horsepower
Torque
Speed
Temperature Rise
D-8
MOTOR DESIGNS
Each is a value unto itself, but each combines with the others to
produce a total result. A basic understanding of these values,
individually and collectively, is necessary before any real
proficiency in the application of motors can be attained.
Horsepower is the term used to define the rated size or power
capability of the motor and is expressed:
HP = (Torque x RPM) / 5250
From this formula it is easy to see the relationship between
Torque, Speed and Horsepower. Due to the fact that motors
are rotating machines, the force the motor produces to do work
is expressed as Torque (discussed in detail later). Keeping this
Horsepower formula in mind, Torque can be expressed as:
Torque = (5250 x HP) /RPM
It is this relationship between Horsepower, Torque and Speed
that must be understood before you can safely evaluate the
proper motor for any given application. Most motor applications
have very specific load requirements which require certain
Torque, Horsepower and Speed. The sales engineer can evaluate
what size motor or what Horsepower motor will produce the
Torque required to drive the load at specified speeds. For
example, using the same Horsepower formula, the motor’s
Speed (RPM) can be expressed as:
RPM = (5250 x HP) / Torque
If you need to know how much Torque a 200 Horsepower, 1784
RPM (4 Pole) motor can produce at full load (normal rated
conditions) you would perform this calculation:
Torque = (5250 x 200HP) / 1784 RPM
Torque = 588 lb-ft
To illustrate the relationship of Speed and Torque further, we
will use the same 200HP rating but change the speed to 1185
RPM (6 Pole):
Torque = (5250 x 200HP) / 1185 RPM
Torque = 886 lb-ft
In this example it is easy to see that a slower 6 Pole motor can
produce significantly more torque that a faster 4 Pole motor of
the same Horsepower rating.
Now lets consider a customer that requires a motor that can
produce 875 Lb-ft of Torque but at a Speed of 3600 RPM (2
Pole). We know from the previous example that a 200HP motor
running at 1200 RPM (6 Pole) speed can produce 886 Lb-ft of
Torque but, what size or Horsepower motor will produce this
Torque at the faster speed of 3600 RPM?
HP = (886 lb-ft x 3600 RPM) / 5250
HP = 607.5 HP
This is a substantially larger and more expensive motor than the
200HP motor.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
MOTOR DESIGNS
Torque Terminology
Torque and force are sort of blood brothers. The term “Force”
is used when dealing in linear motion, and the term “Torque”
when dealing in rotary motion.
Torque is a product of force (pounds) times radius (feet). Thus
the value is expressed in “pound-feet” which indicates “X” the
number of pounds at a one-foot radius (or any combination of
radius and force whose product equals “X”).
Torque is used two ways. In the case of a piece of machinery,
torque indicates the rotational force required to drive the
machine. In the case of a motor, torque indicates the rotational
force that the motor can produce.
The typical AC induction motor speed-torque curve shown
below illustrates some of the various types of torque with which
you will be dealing.
The next term, “pull-up torque” (also called “minimum
torque”) is shown at (2). This is the minimum torque developed
in the “cusp” area just above starting torque. It should be noted
that many motors do not develop this cusp characteristic.
“Breakdown torque” is the maximum torque that the motor
can develop without stalling. This is shown by the arrow at (3)
as being the maximum value reached by the torque curve. This
characteristic is sometimes called “pull-out torque”.
“Full-load torque” is the torque that the motor develops in
producing rated horsepower at rated full-load speed, as shown
at (4). You might think of this as “rated torque”.
“Accelerating torque” is the “plus” torque developed by the
motor that is beyond the torque required by the load at any
given speed. It is shown by the shaded area between the
motor-torque curve and the load-torque curve at (5).
“Starting Torque” is the torque developed at the instant the
motor is started. In essence, the rotor is stationary, but only for a
moment. The arrow at (1) shows starting torque. Starting torque
is also called “locked-rotor torque” or “breakaway torque”.
TORQUE TERMINOLOGY
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D-9
INDUCTION MOTOR REFERENCE GUIDE
MOTOR DESIGNS
NEMA Designs A, B, C
It is important to understand the characteristics of each of these
NEMA designs. In most cases you will use the standard NEMA B
design. However, there will be times when an A, C, D or F design
will handle the job better.
About the best way to become familiar with these
characteristics is to analyze the speed-torque curves for each of
the NEMA designs.
The graph shown below shows the speed-torque curves for
NEMA designs A, B and C. Curve B is dotted because it was
discussed on the previous page. Curve A is dotted because its
characteristics are much like those of curve B. As you will note,
design A has a slightly higher breakdown torque than design B.
Designs A and B are similar in basic characteristics. The
difference lies in the fact that starting currents for design B
motors are limited by NEMA standards. There is no limitation on
starting current for design A.
Breakdown torque, on the other hand, is lower than that for
either A or B. Although there is no definite point for breakdown
torque, its value is established at about 190% (10HP example –
85 1/2 lb-ft).
Full-load torque is the same as that for both A and B.
The curve (1) is the same loaded rolling mill speed-torque
curve shown below . Here you see that a design C motor can
handle this load because of its higher starting torque. In
keeping with the basic speed-torque rule, all parts of the load
curve fall to the left of the motor curve.
NEMA C motors have a double-deck rotor in which the upper
deck consists of a small, high-resistance winding. This upper
deck would be subject to severe heating during prolonged
accelerations. For this reason, design C motors should not be
used on applications requiring frequent accelerations or
involving high inertia loads. The best feature of this design is
its high starting and accelerating torque.
As shown by the solid-line curve, a NEMA design C motor
has a higher starting torque than either the A or B design. This
torque is about 225% which, in the case of the 10HP example,
is 101 lb-ft.
SPEED-TORQUE CURVE - NEMA C
D - 10
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
MOTOR DESIGNS
NEMA Design D
In order to average out the load, a heavy flywheel is used to
store energy from the motor during 343º of travel, and to give
up this energy during the 17º working portion of the cycle.
The solid-line curve in the following figure shows the
characteristic of a NEMA design D motor. This design produces
a very high starting torque (1) which is approximately 275% of
full-load torque. However, it has no true breakdown torque, as
evidenced by the fact that torque continues to decrease all the
way up the speed ladder.
Energy is removed from the flywheel by deceleration…. 10%
slowdown is a typical value. In the example, the average
horsepower required is 40. Consider what will happen in one
case where a 40HP, NEMA B motor is used; and in the other case
where a 40HP, NEMA D is used.
Another somewhat unusual characteristic of this motor is its
high slip at full-load torque (2). The particular curve is that of a
design D motor having a slip of 10%. However, design D motors
with other values of slip are made. Two different designs have
been standardized…one is the 5 to 8% slip motor, and the other
is the 8 to 13% slip motor. Special designs can be made with slip
values up to as much as 20%.
The characteristics of this design are useful in meeting the
needs of two broad application categories. First, the high
starting torque equips this motor to handle hard-to-start loads,
particularly of the pulsating type. Second, the sloping speedtorque curve fits this motor for application where it is desirable
to have the motor slow down during periods of peak load so
that flywheel energy of the load can be released. Typical
applications include press brakes and punch presses. As soon
as the peak load has passed, the motor brings the flywheel
back up to speed in preparation for the next peak.
At point (3) on the accompanying graph, the NEMA B motor
is running at 90% of synchronous speed (10% slowdown) and
165% of full-load torque (65% overload). However, note that
the NEMA D motor is running at just about full load (at 10%
slowdown).
Actually, a NEMA B motor would never let the flywheel slow
down to 90% synchronous speed, because of the great increase
in torque. The NEMA B motor will try to force the flywheel to
run at a much higher speed, thus overloading the motor and
preventing the flywheel from giving up a large portion of the
usable kinetic energy it has stored.
The advantage then, of the high-slip NEMA D motor is its ability
to “roll with the punches” on flywheel applications.
FOR EXAMPLE:
A 120-ton, 6 inch stroke straight press is being used to punch
1/2 inch thick discs. The stroke length and the thickness of the
metal being cut indicate that this press is doing the work only
17º of flywheel.
SPEED-TORQUE CURVE - NEMA D
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 11
INDUCTION MOTOR REFERENCE GUIDE
MOTOR DESIGNS
NEMA Design F
The speed-torque curve of a NEMA design F motor shows that
this motor has a very low starting torque and only a moderate
breakdown torque. However, this motor has one desirable
characteristic…a low inrush current is required for starting.
It is understandable why the applications of design F are
limited. In general, these motors are used only for easy-to-start
loads where low starting currents are required and low torque
are acceptable. Because of its limited overload capacity, this
motor must be matched to the load very carefully. Typical
applications include fans and centrifugal pumps.
SPEED-TORQUE CURVE - NEMA F
D - 12
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
POWER SUPPLY
Comparison of NEMA Design Characteristics
In many large cities where 120/208 volt networks are employed,
commercial and small industrial loads are usually 200 volt, 3
phase, 60 Hz. All Optim® motors up to 125 Horsepower are
usable on 208 volt networks however, motor torque, current
and efficiencies will be greatly effected.
The foregoing discussion of speed-torque curves emphasizes
the fact that the five basic NEMA designs vary from one another
to two important points…
STARTING TORQUE and BREAKDOWN TORQUE. An over-all
picture of the relationship of these values is shown below.
Motors for 2300V/4160V can be furnished on motor frames
444T and larger. Usually, because of the cost of starting
equipment for this higher voltage, 2300V/4160V motors are
rarely used below 150 Horsepower. Global Series motors rated
for 2300V/4160V are available from 100 to 1250 Horsepower
(Contact your local TECO-Westinghouse Representative for more
information).
How NEMA Speed-Torque Characteristics Are Classified
NEMA DESIGN A
Starting Torque NORMAL - Starting Current NORMAL
Breakdown Torque HIGH – Full-load slip LOW
Locked Rotor kVA Code Letter
When AC motors are started with full voltage applied
(across-the-line starting), they draw line currents substantially
greater than their full load running current. The magnitude of
the “Inrush Current” is a function of motor Horsepower and the
design characteristics of the motor. In order to define the inrush
characteristics and present them in a simplified form, a series
of code letters have been established. These code letters group
motors depending on the range of inrush values and express
the inrush current in terms of kVA (Kilovolt Amperes).
NEMA DESIGN B
Starting Torque NORMAL – Starting Current LOW
Breakdown Torque MEDIUM – Full-load slip LOW
NEMA DESIGN C
Starting Torque HIGH – Starting Current LOW
Breakdown Torque NORMAL – Full-load Slip LOW
By using the kVA basis, a single letter can be used to define both
the low voltage and high voltage inrush values on dual voltage
motors.
NEMA DESIGN D
Starting Torque VERY HIGH – Starting Current LOW
Full-Load Slip HIGH
The code letter designations and their values appear in the
following table:
NEMA DESIGN F
kVA/HORSEPOWER CODES
Starting Torque LOW – Starting Current VERY LOW
Breakdown Torque VERY LOW
CODE
Full Load Current
As the torque on a motor increases, the line current (amperage)
increases. The electrical wiring and controls providing power to
the motor must be adequately sized to handle the maximum
sustained current that the motor requires when it is fully loaded.
Thus, the electrician installing the motor must use the
nameplate “Full Load Current” data to correctly size the power
supply wiring and starter for the motor. In addition, once the
motor has been put into service, line amperage can be utilized
to determine if the motor is being overloaded. It is important
to note that the motors line current and operating temperature
will increase when it is subjected to either undervoltage or
overvoltage.
Voltage
In most industrial plants the power supply usually found for the
average size polyphase motor is 460 or 575 volts, 3 phase, 60 Hz
and the majority of T-Frame motors sold fall in this voltage and
frequency class.
kVA/HP
MID-VALUE
A
0.00 – 3.14
1.6
B
3.15 – 3.54
3.3
C
3.55 – 3.99
3.8
D
4.00 – 4.49
4.3
E
4.50 – 4.99
4.7
F
5.00 – 5.59
5.3
G
5.60 – 6.29
5.9
H
6.30 – 7.09
6.7
J
7.10 – 7.99
7.5
K
8.00 – 8.99
8.5
L
9.00 – 9.99
9.5
M
10.00 – 11.19
10.6
N
11.20 – 12.49
11.8
P
12.50 – 13.99
13.2
R
14.00 – 15.99
15.0
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 13
INDUCTION MOTOR REFERENCE GUIDE
POWER SUPPLY
60 Hz. Therefore, a motor rated 100HP at 60 Hz is normally
rated for 83HP when operated on 50 Hz power. The
conservative design of many TECO-Westinghouse motors
allows for 50 Hz operation without HP de-rating. Contact
your local TECO-Westinghouse representative for more
details.
To determine the across the line starting inrush amperes from
the code letter designation, the code letter value, horsepower,
and rated operating voltage are inserted in the following
equation.
Locked Rotor Amps =
((code letter value) x HP x 577)
Rated Voltage
• Torque, current and efficiency values will also be different
for motors when operated on 50 Hz power. Contact your
local TECO-Westinghouse representative for these values
when using a motor with 50 Hz power.
The simplified equations will give approximate results.
200 Volts:
230 Volts:
460 Volts:
575 Volts:
L R A = Code letter value x HP x 2.9
L R A = Code letter value x HP x 2.5
L R A = Code letter value x HP x 1.25
L R A = Code letter value x HP x 1.00
The Performance data table gives the kVA/HP code letter for
each rating. Generally, standard motors of 15HP or larger, will
have code letters for G, or lower, 10HP and smaller will have
code letters of H, or higher.
Rated Frequency and Number of Phases
This indicates the frequency for which the motor is designed
in Hertz (cycles per second). Hertz is normally abbreviated Hz.
60 Hertz power is utilized throughout the United States and
Canada. 60 Hertz is also in a few foreign countries where there
has been a strong American influence, however, 50 Hertz is the
dominant system frequency in the majority of foreign countries.
When motors are supplied for export shipments, it is vitally
important to double check the required voltage and frequency.
In most industrial and commercial installations, the power
systems, and consequently the induction motors, will either be
single phase or three phase. The simplicity of the 3 phase
induction motor makes it the natural choice for all requirements
where 3 phase power is available. Single phase motors may be
used on fractional horsepower requirements (less than 1HP) and
in applications such as agricultural installations where 3 phase
power is not available.
Service Factor
A horsepower rating does not necessarily indicate a motor’s
maximum capacity. This is where “service factor” enters the
picture. Service factor is a multiplier that indicates how much
the motor may be safely overloaded.
The service factor is applied simply by multiplying it times the
rated horsepower. The result is the maximum horsepower at
which the motor may be operated.
It is important to remember that the value obtained by applying
a service factor is valid only if usual service conditions, rated
voltage and rated frequency are maintained. Also, it should be
noted that the resultant overloaded state will increase the
temperature rise and may affect the motor’s efficiency, power
factor and speed. The resulted increase in temperature rise can
drastically reduce motor life, for every 10°C increase in motor
temperature the expected life of the motor winding is cut in
half.
Example of how service factor is applied:
SQUIRREL-CAGE, TEFC, 40ºC
10
X 1.15
11.5
50 Cycle Motors
CHANGE IN TORQUE AND SPEED (1800 RPM Motor)
While it is best to have a motor specifically designed for 50 Hz
power systems, it is possible to use 60 Hz rated motors with 50
Hz power supply provided the following conditions are satisfied:
• In order for the motor to operate safely within thermal
limits and generate sufficient output, it is important that
balanced frequency and voltage power is supplied to the
motor. Therefore, a motor designed for 460 volt, 60 Hz, is
normally operated on the following voltage for 50 Hz
power:
60 Hz / 460 V = 50 Hz / Preferred Voltage
Preferred Voltage = (50 Hz x 460 V) / 60 Hz
Preferred Voltage = 383 V or 380 volts
• The rated performance of a motor will change when
operated on 50 Hz power. Horsepower output will be
approximately 50 Hz / 60 Hz = 83% of its rated value at
D - 14
rated horsepower
service factor
overloaded capacity (HP)
30.1 x 1745
5250
35 x 1728
5250
= 10 HP
= 111/2 HP
Actually, a service factor is an indication of a motor’s safe
internal operating temperature. When a horsepower rating is
established for a specific motor design and size, it is based on
two factors: (1) the total power that the motor can produce,
and (2) the amount of internal heat that the motor insulation
can withstand.
The internal heat factor usually dictates a rating below the
motor’s momentary power output capacity. In addition, a
margin of safety is often applied to the internal heat factor. It
is this margin of safety that makes the service factor possible.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
MOTOR EFFICIENCY
Motor Efficiency
Payback Analysis
A perfect motor would be a motor that could convert electrical
power to mechanical power with 100% efficiency. Expressed
mathematically, the perfect motor would convert 746 watts
of electrical power to one horsepower of mechanical output
power.
Competitor Motor’s Yearly Energy Cost
Real motors are not able to achieve this ideal goal, however, the
larger a motor becomes, the closer it will come to approaching
100% efficiency. In most cases the efficiency of a motor is
approximately constant, when operated at 1/2 or more of its full
load torque rating.
The motor’s losses or energy that is not converted into
mechanical power turns into heat within the motor frame.
This heat must be transferred out of the motor via the cooling
medium (see the section on Enclosures for more detail).
A motor’s efficiency is expressed as:
Efficiency =
74.6 KW
0.94 Eff.
X
24 Hours
Day
X
340 Days
Year
X
$0.06 per KW Hour
X
340 Days
Year
X
$0.06 per KW Hour
TWMI Motor’s Yearly Energy Cost
$38,609
=
74.6 KW
X
0.946 Eff.
24 Hours
Day
Savings
COMPETITOR
$38,855 Yearly Energy Cost
$2,718 Motor Price
TWMI
-$38,609 Yearly Energy Cost
-$3,087 Motor Price
SAVINGS
$246.00 Per Year
$369
Pay Back Period
In this example, a high quality, energy efficient Optim® motor
that costs a full 12% more than the competition’s is in the long
run a much less expensive motor to own and operate.
1
( Efficiency
)
–1
Premium Efficiency motors are specifically designed for low
losses and to be highly efficient. This is important to industrial
plants which operate large numbers of electrical motors which
utilize great amounts of electrical power. Although Premium
Efficiency motors are more expensive than the average motor,
they pay for themselves over long periods of time with the
money saved on utility bills. The following page provides
an example of how TECO-Westinghouse Premium Efficiency
Optim® TEFC motors can save the customer money.
STARTING METHODS
Starting Methods for Squirrel Cage Motors
All of our AC motors are designed and built to withstand
full-voltage starting.
However, there may be conditions which would dictate the use
of reduced voltage starting. They are:
1. kVA inrush limitations imposed by the power company
2. Mechanical shock to driven equipment
3. Excessive voltage drip and its effect on adjacent equipment
TECO-Westinghouse Motors (Canada) Inc.
Energy Saving Example
This example compares two 100HP, 1800 RPM, 460 Volt, TEFC,
1.15 Service Factor Motors.
Required Information:
Efficiency of Competition’s Motor
94.0%
Efficiency of TWMI’s Motor
94.6%
Price of Competition’s Motor
$2,718.00
Price of TWMI’s Optim® TEFC Motor
$3,087.00
Energy Cost per Kilowatt (KW) Hour
$0.06
Days of Motor Operation Per Year
340
Hours of Motor Operation per Day
24
Kilowatt (KW) Rating of Motors (0.746 x HP)
=
1.5 Payback Years = $369 Price Difference
$246 Energy Cost Difference
Output KW
(Output KW + Losses)
Losses = Output x
$38,855
In many countries, the star-delta system of starting is employed.
Here, the control first connects the motor windings in star for
starting and after the motor is up to speed, connects the
winding delta for running. By starting with the windings
connected star, the inrush is reduced by 57% of what it would
be had the motor been started delta connected. The starting
torque and pullout torque are reduced to 34% of the normal
values so that this method of starting is limited mostly to
machines started unloaded.
When reduced voltage starting is desired for squirrel cage
motors having normal windings, there are three types of
controls:
1. Auto-transformer
2. Resistor
3. Reactor
74.6
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 15
INDUCTION MOTOR REFERENCE GUIDE
STARTING METHODS
Auto-Transformer
An auto-transformer starter is essentially a transformer with
a step-down tap plus a switching device that connects the
motor to the transformer for starting and directly to the line for
running. The transformer taps are normally supplied for values
of 50%, 65% or 80% of the line voltage. Starting torque varies
as the square of motor terminal voltage. The values for the three
standard taps are as follows:
Auto-transformer Tap
% Line Voltage
Starting Current
% Normal
Starting Torque
% Normal
50%
25%
25%
65%
42%
42%
80%
64%
64%
Resistor
This method utilizes a resistor in series with each phase of
the motor, to reduce line current for starting. The resistors
are short-circuited when full speed is reached. If a high value
resistor is short-circuited in increments, it is possible to increase
the line current gradually until a value is reached that is
adequate to start the load.
The table at the top lists typical values of voltage, current and
torque obtained with some of the most common methods of
reduced-voltage starting.
As indicated, the values shown in this table are the percent of
the corresponding value that would be obtained if full-voltage
starting were used. Take the case of the auto-transformer. If an
80% voltage starting current, and the starting torque would be
64% of the full-voltage starting torque.
For the moment, the main consideration is the last column….
percent of full-voltage torque. This shows that with resistor,
reactor or auto-transformer starting, the starting torque varies
as the square of the motor terminal voltage. With part-winding
starting, the starting torque varies directly as the portion of the
winding that is used for starting. With star-delta starting, the
starting torque is always 33% of the full-voltage starting torque.
The resulting starting-torque values, based on the data in the
table, are plotted on the speed-torque curve at the bottom
of the page. The full-voltage curve is that of a NEMA design B
motor. Other NEMA designs would, of course, produce other
reduced-voltage curves. It should be remembered that the
reduced-voltage curves apply only during the starting period.
As soon as full voltage is applied, the motor characteristics then
revert to the full-voltage values.
Reactor
Reactor starting is not as common as resistor or autotransformer starting, but there are occasions when it can be
used to good advantage. The method is very similar to the
resistor method, except that series reactors are used instead
of resistors. Short-circuiting the reactor for running is similar
although step short-circuiting is not generally feasible. This
method of starting is more commonly used with higher voltage
motors 2300 volts and above.
Reactors are also used as inductive devices to filter unwanted
harmonics and voltage spikes generated by variable frequency
drives.
Effect of Reduced Voltage Starting
The starting torques discussed so far are those values obtained
when full voltage (across-the-line) starting is used. However,
there are cases where the current required for full-voltage
starting cannot be permitted, and thus reduced-voltage starting
must be used to limit the starting current. In as much as torque
varies as the square of the applied voltage, the values of starting
torque will decrease when reduced-voltage starting is used. An
indication of the result is shown on the following page.
D - 16
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
STARTING METHODS
REDUCED - VOLTAGE SPEED - TORQUE CURVES
Voltage
RESISTOR
REACTOR
PART WINDING
AUTO TRANSFORMER
STAR-DELTA
80%
80%
80%
57%
PERCENTAGE OF FULL VOLTAGE
Current
Torque
80%
80%
65%
64%
57%
64%
64%
100%
64%
33%
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 17
INDUCTION MOTOR REFERENCE GUIDE
VFD DRIVEN MOTOR APPLICATIONS
Variable Speed Applications
Motor Insulation System & Supply Voltage
A variable frequency drive allows a customer to change the
motor’s operating speed by changing the frequency (Hz) of the
power supplied to the motor. While this is convenient for the
customer, it causes several problems for the motor and special
consideration must be given to the motor’s ability to operate on
various frequencies.
The motor insulation system for VFD approved TECOWestinghouse motors is based on and exceeds NEMA
Standards. As defined in NEMA MG-1 Part 31.4.4.2 the insulation
system must be capable of withstanding voltage spikes of 3.1
x rated line-to-line voltage for motors rated ≤600V and 2.04
x rated line-to-line voltage for motors rated >600V with a rise
time of ≥ 0.1μs. TECO-Westinghouse motors rated ≤600V have
been designed to withstand voltage spikes up to 2000V with a
rise time of ≥ 0.1μs.
• Motors operated below their approved turn down ratio do
not move enough air to adequately cool the motor. This will
cause the motor to run hot and decrease the motor’s life.
• Motors operated above 60Hz will experience decreased
torque output. Additionally, care must be taken to ensure
the motor, and all mechanical devices driven by the motor,
are able to withstand these higher RPMs. Please contact
your TECO-Westinghouse representative for the maximum
safe operating RPM of your motor.
Effects of Harmonics on Induction Motors
Power supplied by (PWM) variable frequency drives contain
harmonic content in the electrical waveforms they generate at
various frequencies. The harmonic content and non-sinusoidal
waveforms generated by the drive can cause the following
problems:
• High harmonics in the waveform increase the motor’s
“hot-spot” causing the motor to run hotter than it would
under normal conditions.
• Voltage spikes at the motor terminals resulting from
harmonics & reflective wave can exceed the rated peak
voltage of the motor winding. The magnitude of the voltage
spike and rise time is a function of the inverter switching
speed (carrier frequency).
• Harmonic frequencies generated by the VFD could excite
resonance in the motor frame resulting in increased noise
and vibration levels.
Voltage spikes and rise time should be measured at the motor
terminals and should not exceed the above given values.
Cable Length & Type
Cable length and type connecting the motor and drive have
a significant influence on the peak voltages occurring at the
motor terminals.
Cable Length
The following conditions should be met when installing
TECO-Westinghouse motors on an inverter:
VOLTAGE
CLASS
NO
FILTERS
LOAD REACTOR
AT VFD
RECOMMENDED
DV/DT FILTER
RECOMMENDED
SINE-WAVE
FILTER
RECOMMENDED
≤480V (LV)
<100 ft.
100 1000 ft.
1001 2000 ft.
2001 3000 ft.
>480V 690V (LV)
<35 ft.
36 - 300 ft.
301 2000 ft.
2001 3000 ft.
Note: Extended cable lengths and greater motor protection
can also be realized through the use of solid state surge
protection devices. Some configurations may yield a greater
cable length protection then those specified.
• Corona effect causing partial discharge on the motor
windings leading to insulation breakdown.
Although filters may not be required at some cable lengths,
they are always recommended to better protect both the motor
and VFD.
• Capacitive discharge from the motor shaft to ground causing
pitting of the bearings leading to bearing failure.
Please contact TECO-Westinghouse for application specific
recommendations.
Cable Type
VFD approved shielded cable is recommended to minimize
the effects of reflected wave, provide a proper grounding path
attributing to a balanced and low reference potential and
reduce the commode mode voltage.
D - 18
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
VFD DRIVEN MOTOR APPLICATIONS
Motor Shaft Voltages & Bearing Currents
VFD Carrier Frequency Settings
Shaft voltages and resulting circulating currents caused by
magnetic dissymmetry’s in the construction of larger motors,
typically 5000 frames and larger, can be increased by the
effects of high frequency components present in the voltage
supplied by PWM inverters. The path of these induced currents
is through the bearings and motor frame and can be prevented
by insulating one of the bearings, preferably the non-drive end
bearing, to avoid creating a loop through the driven equipment.
High switching frequencies increase the rate of current
discharge through the bearings and increase the rate of
insulation breakdown in the motor windings. The carrier
frequency should be set between 2 kHz and 5 kHz.
Common mode voltages imposed on the rotor by capacitive
coupling between the rotor and stator can result in discharge
through one or both bearings to ground; therefore insulating
both bearings is required to prevent current flow. Shaft
grounding brushes may also be used to divert current around
the bearings and to prevent the current from damaging the
driven equipment.
VFD Application in Hazardous Locations
Motors operated on VFD power in hazardous areas require
special consideration; please contact TWMI for filtration
and bearing protection options suitable for use in these
applications.
Electrical discharge through the bearings causes an electric
discharge machining (EDM) effect, resulting in pitting of the
bearing’s rolling elements and raceways. Eventually this will lead
to bearing failure and leaves a distinct pattern in the bearing
race called “fluting”.
The following conditions should be met when installing TECOWestinghouse motors on a VFD:
FRAME
SIZE
SHAFT GROUND
BRUSH / RING
INSULATED
NDE BEARING
INSULATED
DE BEARING
≤ 400T
440T
Recommended
-
-
Recommended
Recommended
-
≥ 5000
Recommended
Recommended
Recommended
Note: It is not advisable to use shaft ground brushes on both
ends as this will provide a path for circulating currents.
An alternate method of reducing damaging shaft currents is
with the use of dV/dt or Sine-wave filters on the output of
the VFD.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 19
INDUCTION MOTOR REFERENCE GUIDE
INSULATION
Insulation Types and Temperature Rise
2. Phase Insulation:
The various coils in a motor are connected together in the
three phases. The coils in one phase must be insulated from
the coils in another phase. TECO-Westinghouse uses a sheet
of either Dacron Glass Cloth or DMD (Dacron Mylar Dacron)
between the coils of the different phases.
Functions of Motor Insulation
Motor insulation has two basic functions:
1. It separates the various electrical components from one
another.
3. Ground Insulation:
The winding must be insulated from the stator iron in the
motor. An insulation barrier (slot liner) of DMD (Dacron Mylar
Dacron) is placed in the slot.
2. It protects itself and the electrical components from attack
of contaminants and other destructive forces.
To best perform these functions, five specialized elements are
used, which together constitute the INSULATION SYSTEM. The
following are typical in an AC motor:
4. Slot Wedges:
The wedges are made of DMD and hold the conductors
firmly in the slot.
1. TURN-TO-TURN INSULATION between separate wires in each
coil. (Usually enamel on random-wound coils of smaller
motors – tape on “form-wound” coils or larger motors).
5. Varnish:
The complete winding is given a non hydroscopic
polyester varnish immersion and oven cure to bond the
above materials together as well as the individual turns in
the coil. This gives a good protective seal against moisture
and contaminants. All motors receive two immersions and
oven cure cycles. The bake-cycle is from 3 to 17 hours
depending on the size.
2. PHASE-TO-PHASE GROUND INSULATION between adjacent
coils in different phase groups. (A separate sheet material on
smaller motors – not required on form-wound coils because
the tape also performs this function).
3. PHASE-TO-GROUND INSULATION between windings as a
whole and the “ground” or metal parts of the motor. (A sheet
material, such as the liner used in stator slots, provides both
dielectric and mechanical protection.)
4. SLOT WEDGE to hold conductors firmly in the slot.
5. IMPREGNATION to bind all other components together
and fill in the air spaces. (A total impregnation, applied in
a fluid form and hardened, provides protection against
contaminants).
CROSS SECTION OF STATOR COILS AND INSULATION
Insulation Types and Temperature Rise
One of the most critical items relating to the life of any type of
electrical equipment ranging from television sets to giant power
generators is the maximum temperature that occurs at the
hottest point within the unit and the length of time that the
high temperature is allowed to exist.
To draw an analogy: The aging process in human beings is to a
large extent determined by years and stress. Accidents, natural
disasters, diseases and other illnesses can intervene to shorten
an individual’s life expectancy in the same way that lack of
proper maintenance, overloads, moisture, chemical fumes, low
and high voltages can shorten motor life.
Similarly, basic motor insulation life, when not complicated by
these factors, is determined by time (age) and temperature
(stress).
The maximum allowable safe operating temperature occurring
at the hottest spot within a motor is determined by:
1. The temperature of the air surrounding the motor. This is
the ambient temperature.
2. The heat created within the motor due to its operation at a
fully loaded condition. This is the temperature rise.
3. The thermal capability of all the insulation materials used
within the motor. For simplicity these materials have been
broken into classes A, B, F and H.
1. Turn-to-Turn Insulation:
A coil consists of a number of turns of round copper magnet
wire. These turns of wire are insulated from each other using
a 200ºC rated polyester enamel.
D - 20
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
INSULATION
Service Factor
The four basic insulation classes and their IEEE ratings are as
follows:
CLASS
HOT-SPOT TEMPERATURES
A
B
F
H
105ºC
130ºC
155ºC
180ºC
Service Factor is a percentage multiplier applied to the
nameplate horsepower to obtain the continuous overload
capacity of the motor.
Thus, a standard TEFC 10HP, Class F insulated motor could carry
continuously 1.15 x 10HP or 11.5HP.
It is important to remember that the value obtained by applying
a service factor is valid only if usual service conditions, rated
voltage, 40ºC ambient, and rated frequency are maintained.
Also, it should be noted that the resulting overload state will
increase the temperature rise and may affect the motor’s
efficiency, power factor and speed.
These four classes have been standardized by NEMA.
Most AC motors now use Class F insulation, but in the past,
Class B has been the most common. IEEE (Institute of Electrical
and Engineering and Electronics Engineers) definitions for these
four classes are as follows:
Some motors are rated at their maximum temperature and
therefore their service factor is given as 1.0.
CLASS A: Materials or combinations of materials such as
cotton, silk and paper when suitably impregnated or
coated, or when immersed in a dielectric liquid such
as oil. Other materials or combinations of materials
may be included in this class if by experience or
accepted tests the total system can be shown to be
capable of operation at 105ºC.
CLASS B: Materials or combinations of materials such as mica,
glass fiber, polyesters and aramid laminates, etc.,
with suitable bonding substances. Other materials or
combinations of materials, not necessarily inorganic,
may be included in this class if by experience or
accepted tests the total system can be shown to be
capable of operation at 130ºC.
CLASS F: Materials or combinations of materials such as mica,
glass fiber, polyesters and aramid laminates, etc.,
with suitable bonding substances. Other materials or
combinations of materials, not necessarily inorganic,
may be included in this class if by experience or
accepted tests the total system can be shown to
be capable of operation at 155ºC. All TECOWestinghouse motors use Class F insulationas
standard.
CLASS
20,000 HR. LIFE TEMPERATURE
A
B
F
H
105ºC
130ºC
155ºC
180ºC
WHERE DOES THIS TEMPERATURE COME FROM?
Basically the temperature build-up comes from two
fundamental components and an allowance factor.
The three ingredients are:
1. The ambient or room temperature.
2. The temperature rise that occurs due to the heat generated
by the mechanical and electrical losses within the motor.
3. Finally, due to the fact that the standardized motor
temperature measurement method (change in winding
resistance) measures the average temperature of the
complete windings rather than the hottest spot (the point
of highest thermal stress) an allowance factor called the
“hot spot allowance” must be added.
CLASS H: Materials or combinations of materials such as
silicone elastomer, mica, glass fiber, polyester’s and
aramid laminates, etc., with suitable bonding
substances such as appropriate silicone resins. Other
materials or combinations of materials may be
included in this class if by experience or accepted
tests the total system can be shown to be capable of
operation at 180ºC.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 21
INDUCTION MOTOR REFERENCE GUIDE
INSULATION
FIELD SERVICE
With referece to Class B insulated, Class B temperature rise,
T-frame, 1.0 Service Factor, totally enclosed motor operating at a
rated horsepower and rated voltage, these ingredients work out
as follows:
1. Ambient Temperature
2. Temperature Rise (maximum allowable)
3. Hot Spot Allowance
CLASS B
40ºC (104ºF)
80ºC (176ºF)
10ºC (50ºF)
CLASS F
40°C (104°F)
105°C (221°F)
10°C (50°F)
Total Temperature max (Hottest spot)
130ºC (266ºF)
155ºC (311ºF)
For service factored motors running at the service factor full
load – i.e. 115% of rated load, the ingredients are as follows:
1. Ambient Temperature
2. Maximum Temperature Rise
3. Hot Spot Allowance
40ºC
90ºC
10ºC
140ºC
Since 140ºC is 10ºC above the 130ºC Class B rating, you could
expect the motor’s thermal life to be cut in half if it runs
continuously at the 15% overload conditions.
However, TECO-Westinghouse motors have Class F insulation
systems as illustrated above. Therefore, the hottest allowable
temperature is 155ºC, well above the 140ºC temperature rise
generated by the motor running at 1.15 service factor. A motor’s
service factor capability should only be used when short term
overloads are expected or when the motor is to be used in an
environment where the ambient temperature contribution to
the total temperature is know to be less than 40ºC.
If motors are operated at rated load rather than service factor
load, the temperature rise will be less than 80ºC so minimum
normal life, or more, can be expected.
A. EXCESSIVE VIBRATION
One of the most frequent complaints of motor troubles in the
field is excessive vibration. The maximum vibration amplitudes
often occur on the motor, and the user will conclude that the
motor is the source of the trouble. Sometimes this is correct, but
in the majority of such instances, the cure does not involve the
motor.
Vibration is detrimental to all rotating equipment and should
be minimized. In recognition of this requirement, NEMA has
adopted standards for “maximum allowable” vibration (NEMA
MG 1-1998, 7.8) and the conditions under which it should be
determined. TECO-Westinghouse’s commercial test limits for
vibration will not exceed the maximum specified by NEMA.
It should be understood that a rotating motor or any rotating
machinery always has some vibration. The best balancing
methods can never attain perfect balance. An idle machine
exhibits no vibration. When the motor is energized the
vibration appears.
Before the motor is removed and sent to a repair shop the user
should examine the entire machine and eliminate all possible
external contributing factors.
When a motor is applied to an installation it becomes part of a
system consisting of one or more drivers (motors), the driven
equipment (one or more units), the foundations(s) and the
mechanisms by which the components are interconnected,
(coupling, belts, etc.). Any one of these components can be the
cause of, or contribute to, excessive system vibration.
The most common causes of “excessive vibration” are:
1. “Resonant” foundation or structure
2. Poor alignment (cold and/or hot)
3. Loose “hold down bolts” securing the apparatus to its
mounting
4. Unbalance in the motor, coupling(s), driven equipment (etc.)
FIELD SERVICE
Motor – Field Service
All TECO-Westinghouse Motors have been designed for long
reliable service. However, any man-made product manufactured
in such large quantities and installed under such a variety of
conditions is likely to occasionally develop real or imaginary
difficulties.
In cases where excessive vibration is occurring, the
recommended steps for isolating the trouble involves the
study of both amplitude and frequency of vibration as follows:
The more common user complaints can be combined under the
following seven headings.
Step 1: During operation, measure the actual vibration
amplitudes with suitable instrumentation (such as an
IRD Vibration Analyzer, Davey Vibrometer, etc.) at the
motor bearing housings in the vertical, horizontal, and
axial directions.
A.
B.
C.
D.
E.
F.
D - 22
Excessive vibration
Noisy
High Current
Running Hot
Bearing Failed
Motor Burned Out
1 – RESONANT FOUNDATION
Step 2: Measure the vibration amplitude of the foundation
structure during operation to determine background
vibration (if the foundation is shaking due to a resonant
condition, or to vibration being fed in from an external
source, this vibration will affect the magnitude of
vibration which appears on the motor.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
FIELD SERVICE
If the vibration frequency of the foundation is low (less than
50%) compared to the operating speed of the motor the
movement of the foundation will tend to be in phase with
the movement of the motor. Therefore, the total vibration
amplitude appearing on the motor will be the sum of the
motor vibration plus foundation vibration.
If the vibration frequency of the foundation is high (more than
150%) of the operating speed the movement of the foundation
will tend to be opposite (approaches 180ºC out of phase) in
direction to the movement of the motor, and the vibration
amplitude which appears on the motors will be the difference
between the motor and foundation vibrations alone. (This
condition is extremely rare and is almost always due to a source
external to the motor and supporting structure.)
If the foundation frequency lies within the range of 50% and
150% of operating frequency the phase relationship between
motor and foundation amplitudes becomes complex and a
meaningful determination requires the use of a vibration meter
with a filter to measure the amplitude and phase of each
frequency component. Such measurements and analysis are
usually required only to identify an elusive source of external
vibration.
Step 3: Determine the natural frequency of vibration of the
rotating system at rest. Vibration at the natural
frequency can usually be induced by “bumping” the
motor at the same location and in the same plane
where the maximum vibration was measured in Step 1.
If the natural frequency is close (in the range of 1/2 to 2/3) to
the operating frequency of a multiple of operating frequency
(called a harmonic) it must be changed to avoid resonance. This
can best be accomplished by reinforcing and stiffening the
system foundation.
Vibration may occur in the supporting structure if there is
insufficient mass built into the foundation. The foundation
structure is usually concrete or steel or a combination of the
two.
A concrete structure may have its mass or weight increased
by adding to its size or thickness by building a frame around
and pouring in more concrete. If this is not desirable another
remedy is to add to the mass and at the same time improve the
resonance characteristics by pouring lead into a hole in the
base. For instance, drill a hole in the concrete about 2” in
diameter and 15” to 20” deep and fill with molten lead. The hold
can be at a convenient location in the base and at an angle or
vertical horizontal.
2 - POOR ALIGNMENT
Step 4: Check and correct system alignment both cold and
hot (at system operating temperatures). For machines
with operating speeds below 2000 RPM parallelism and
angularity of the component shafts and couplings
should be within .002 inches for machines with
operating speed of 2000 RPM or higher the parallelism
and angularity should be within .001 inches.
3 - LOOSE HOLD DOWN BOLTS
Step 5: If the natural frequency is well above the operating
frequency (150% of operating speed or more) and
not a harmonic, look elsewhere – check the system
components to make certain that they are properly
shimmed, leveled and firmly tied down to the
foundation structure.
4 - UNBALANCE IN MOTOR
Step 6: While the motor coupling is broken, energize the motor
and measure the vibration amplitude as in Step 1.
NOTE: Assuming that resonance is not present the uncoupled
motor should exhibit vibration amplitudes within the limitation
of NEMA standards. It is not uncommon for a motor to show a
slight increase (less than 0.001 inch increase in vibration
amplitude when it is sitting on a steel bedplate over what it
demonstrated when it was checked for balance per NEMA Std.
MG-1-12.07 because steel is not as “dead” as the flexible pads
specified by NEMA. However, the presence of vibration
amplitudes appreciably in excess (.001 inch or more) of these
standards indicates an unbalance attributable to the motor
and/or the coupling half.
Step 7: If the motor balance as demonstrated in Step 6 is
satisfactory, the driven equipment and/or its supporting
structure are most probably the source of system vibration.
B. EXCESSIVE NOISE
Complaints of excessive noise in TECO-Westinghouse motors are
rare. The important distinction which must be made is whether
the reported noise indicates an abnormal condition requiring
corrective action to preclude serious damage. The types of
unusual noises which may indicate rapidly progressive damage
are:
1. “Squeals” and associated noises which indicate a loss of
clearance between rotating parts. Noises of this origin must
be investigated and removed immediately. Typical causes
are shifted blowers rubbing on air shields, shafts rubbing on
bearing caps, etc.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 23
INDUCTION MOTOR REFERENCE GUIDE
FIELD SERVICE
2. “Rumbles” and associated noises which indicate a bad
anti-friction bearing. Continued operation may result in
complete failure and drop the rotor onto the stator.
3. Heavy magnetic noises, which indicate misconnection, short
circuit, single phasing, etc. Continued operation may result
incomplete failure and drop the rotor onto the stator.
A difficult complaint to handle is one where an apparently
perfectly good motor is unsatisfactory to one or more persons
because of the noise produced. In such instances it is wise to
keep the following facts in mind when deciding on a course of
action:
1. NEMA Standard MG-1-1998 paragraph 14.3.5 recognized
that “Operation where low noise levels are required” is an
unusual service condition; requiring consultation with
manufacturer during negotiations.
2. TECO-Westinghouse does not guarantee noise levels unless
they are specifically negotiated and incorporated into the
customer’s purchase order and are accepted by the
Company.
3. Noise apparently coming from a motor depends completely
on the generated noise level present in the area from other
sources. Consider how the kitchen refrigerator can be heard
at night when the house is quiet, but is rarely noticed during
the day when normal house noises mask it.
4. Noise associated with a motor may seem to emanate from
the motor, but may really come from “sounding boards”
which become excited by the forces which the motor and
driven equipment place upon their foundations. Providing
firmer foundations or isolation mounting devices often
reduce noise from these sources.
5. Cavities of all kinds, such as ventilator ducts to or from the
motor, small rooms, various shaped nooks and crannies, all
may be excited like organ pipes by normal motor vibratory
forces, and may amplify normal motor noise.
C. HIGH CURRENT
Unusually high currents drawn by an alternating current motor
normally come to the user’s attention through the action of the
overload protection associated with the starter. Commonly, this
protection takes the form of calibrated “heaters” in the leads
to the motor which respond to line amperes and operate bimetalic strips (when overheated) to open the line contactor and
shut down the motor.
Applied voltage higher than the nameplate rating will increase
the current in the motor appreciable until saturation of the
magnetic materials is reached at which point the current
increases very rapidly and the motor will burn out. NEMA
Standards state that induction motors “shall operate
successfully” with a voltage variation of ±10% of nameplate
voltage with rated frequency but that “operating performance
within these voltage variations will not necessarily be in
accordance with the standards established for operation at
rated voltage”. The saturation point must be above rated
voltage plus 10% to provide acceptable performance. However,
it is entirely possible to experience saturation with say a 440 volt
motor being operated on a distribution system supplying say
500 volts at the motor terminals. The saturation point is a
function of the amount of magnetic steel used, the electrical
characteristics of the steel, and the winding design. Any and/or
all of these can be altered to provide optimum performance for
any specified voltage condition, but if the applied voltage is not
precisely controlled, performance will vary from the motor. At
the point where actual voltage exceeds ±10% of rated voltage,
performance will suffer markedly and very possible be entirely
unsatisfactory.
To repeat, high current can be the direct result of high
voltage. Nameplate full load current is stated for rated voltage
conditions and will vary with applied voltage until the magnetic
circuit becomes saturated, at which point current will increase
tremendously. Nameplate voltage at the motor terminals
provides optimum performance.
Higher than expected current may occur for another reason
which is often overlooked. This is true with low speed motors
such as are frequently used for direct connection to low speed
pumps.
At the time when the system designer calculates the plant
circuits, the motor starting equipment and the size of the wires
to the motor he will often refer to standard tables to determine
the full load amperes of the motor. These standard tables apply
to motors of commonly used speeds down to 1200 RPM or
possible 900 RPM. The tables overlook the fact that a motor with
speeds below these values usually has a very low power factor
which results in a considerably higher motor current. The true
higher current figure will be stamped on the motor nameplate
but by the time the motor is received by the user it is probable
that the starter and its circuits will have been installed on the
basis of the lower current shown in the standard tables.
Wherever a slow speed drive is concerned be sure to check the
motor manufacturer for the accurate current value and ask for a
reply in writing so there will be no misunderstanding.
It is assumed that ambient conditions, heater ratings and
horsepower demands of the driven equipment have all been
reconfirmed and found to be satisfactory. Further investigation
reveals that the motor is drawing current appreciable above
the nameplate data at rated load as measured by a calibrated
ammeter. Before condemning the motor make an accurate
check of line voltage at the motor terminals.
D - 24
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
FIELD SERVICE
D. RUNNING HOT
First determine that the machine is actually running over
temperature. Just placing a hand on the machine is not
sufficient to actually decide a machine is exceeding allowable
temperature rise.
It should be remembered that modern standard motors for
any given horsepower rating are smaller and they use Class F
insulation. NEMA standards for Class F insulation allow a total
temperature of 155ºC. Thermometers can be placed on the
frame for measuring the temperature.
The following checks can be made to determine the possible
reasons for a machine running hot:
Check 1 – Is the machine getting enough cool air? The
amount of ventilation should be enough if;
a. The shaft blower is present and clean.
b. The external blower motor is operating (in the case of
external forced air cooling)
c. The shaft or external blower is rotating in the correct
direction.
d. There are no restrictions – air is getting in and out of the
machine.
e. The air is not recirculating from the outlet into the inlet –
Check inlet temperature which should not be more than 5ºC
above ambient.
f. The measurement of inlet and outlet temperature indicates
the temperature rise is normal.
g. The quantity of air is sufficient – check for missing air shield
or improperly fitted air shield. The air shield should be about
1/4” from the vanes and lined up with the vanes.
h. The speed is incorrect – check motor speed with nameplate
rating at full load.
Check 2 – Is the loading on the machine correct? To
determine this:
a. Check the duty cycle – is it continuous or is it being started
and stopped too frequently.
b. Check supply voltage – incorrect voltage causes excessive
full load current and the losses go way up.
c. Check supply frequency (NEMA allows ±5% from normal if
normal voltage is maintained).
d. Check for unbalanced phase-to-phase voltage.
e. Check load voltage and current.
Check 3 – Uncouple motor and take no load readings in each
phase of the voltage, current and watts to determine if they are
normal.
Check 4 – (In places where a number of SCR drives are being
used, check harmonic content of voltage source). SCR drives
put harmonics back in the line and result in negative torques to
the machine which cause heating.
Check 5 – Check the bearings because defective bearings
can increase the load on the motor and in small motors may
become a large percentage of the load and result in overloading
and increased temperature.
CONCLUSION: If all of the above check okay, the application
could be wrong – too small a motor.
E. BEARING FAILURES
One of the most frequent troubles which occurs on motors in
the field is bearing malfunction or failure. Most bearing failures
can be attributed to one of the following cases:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Inadequate, excessive or unsuitable lubrication
Misalignment
Overload
Incorrect of faulty fitting
Damage during installation
Vibration while the bearing is not rotating
Corrosion
Passage of electric current through the bearing
Defective or incorrect bearings
1 – LUBRICATION
(See also - Lubrication Guidelines page D-29)
Perhaps the most common cause of bearing failures is improper
lubrication. If the supply of lubricant is inadequate the bearing
will run dry with consequent overheating and failure. If the
bearing overheats to the point where is loses clearance it will
fail almost immediately. The bearing is usually burned and
severely damaged by this type of failure. If it does not lose
clearance the material in the races and rollers will be damaged.
After a short time particles of material will flake away causing
the bearing to become rough and noisy.
Only a small amount of lubricant is required in a bearing at any
one time, but a small amount of fresh lubricant must be fed
into the bearing to replenish that which is depleted by working
and by oxidation. This action takes place in our motors which
are equipped with unshielded ball bearings. A clearance area
around the edge of the inner bearing cap admits sufficient new
grease while protecting the bearing against the addition of too
much grease.
Too much lubricant can be as destructive as too little. As soon
as a ball or roller bearing begins to rotate, any excess lubricant
is pushed to the side of the ball or roller path. If the bearing
cannot purge itself in this manner, it will churn the lubricant
generating high temperature and pressure. Rapid overheating
of the bearing will result, often causing it lose clearance and/or
to reach temperature where the material loses its temper or the
lubricant itself burns.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 25
INDUCTION MOTOR REFERENCE GUIDE
FIELD SERVICE
When re-lubricating ball bearings, it is recommended that the
motor be stopped and the outlet plug be removed. Add
lubricant with hand lever gun.
The use of the proper type of lubricant is also very important.
In the case of oil it must be viscous enough so that the film of
lubricant will not break down under load, but at the same time
not viscous enough to produce high frictional loads. Grease
must be still enough not to drain out of the bearing reservoir,
but soft enough to settle against the bearing and be fed into it.
As a general rule it is not advisable to intermix different
lubricants. The constituents of different lubricants may not be
compatible and intermixing may cause them to quickly break
down and lose their lubricating qualities.
There are many varieties of lubricants available, most of them
intended for a particular use. There is no such thing as an all
purpose lubricant. The motor manufacturer and/or lubricant
manufacturer should be consulted whenever there is any
question as to whether a lubricant is suitable for a particular
application.
2 - MISALIGNMENT
It is obvious that a misalignment between the motor shaft and
the load shaft will bring about an early failure of the bearing.
With each revolution this misalignment will impose heavy
pressure followed by a relaxing of what pressure on many of the
internal parts of the bearing. At operating speeds this change
from plus to minus excessive pressure will occur so quickly and
frequently as to act like a riveting hammer on the surface of the
balls and races. This will either crack the balls or race or at least
flake off pieces from the surface.
3 - OVERLOAD
As a rule of thumb the life expectancy of a ball bearing is
inversely proportional to the cube of the load. Therefore, an
overall increase in load can cause a relatively large decrease
in bearing life. The material in the bearing races is actually
deformed when the ball or roller passes over it. Eventually the
material will suffer fatigue failure, and pitting and flaking of
material will occur in the ball track.
Heavy radial loads on a bearing may result from misalignment,
or from a belted application where the belts are too tight.
Severe thrust loads can usually be traced to the equipment
which the motor is driving. On belted applications the smaller
the diameter of the sheaves the greater will be the radial loads
imposed on the motor shaft and bearings. If multiple belts (such
as V-belts) are used, the fewer the number of belts, the more
they must be tightened to transmit a given horsepower without
slipping.
D - 26
There are specific recommendations published by NEMA and by
most belt drive manufacturers for minimum sheave diameters,
minimum number of belts of a given size and type, etc.,
required to transmit standard horsepower at various speeds.
Also the belt drive manufacturers publish specific instruction on
how to adjust their drives for proper belt tension.
To evaluate whether or not a particular belt drive is suitable for
use with a given motor the following information is required:
1.
2.
3.
4.
5.
Manufacturer of the belt drive.
Diameter of both drive and driven sheaves.
Center distance between sheaves.
Face width of the sheaves.
Number and type of belts used (for standard V-belts,
type A, B, C, D, or E; for super V-belts, 3V, 5V, 8V, etc).
6. Location of the drive sheave on the motor shaft.
7. Direction of belt pull, relative to the motor.
8. Nameplate data for the motor if this information is not
already known.
It is usually not possible to tell whether the belts were too tight
after a failure has occurred. However, if there are other motors
with similar drives at the same site it might be worthwhile to
check them. If the belts on the other motors are overly tight the
chances are they were on the failed motor also.
4 – FAULTY FITS
There are four important areas where the fit between the
bearing and the other motor parts must be within prescribed
limits to prevent faulty operation.
1. The fit of the bearing inner race on the shaft.
2. The fit of the bearing outer race on the shaft.
3. The internal clearances in the bearing itself between the
balls and races.
4. The overall fit of the rotating assembly made up of the rotor,
shaft, and bearings in the stationary assembly made up of
the frame and brackets.
1. The bearing race which rotates relative to the load has a
tendency to spin if it is not restrained. The friction between
the race and the shaft (or housing, as the case may be) can
generate enough heat to cause the bearing to fail, some
times in a matter of hours.
In the vast majority of motors the shaft rotates and the
inner race of the bearing is assembled on the shaft with an
interference fit. On smaller frame sizes this fit will vary from
.001 inches to .0012 inches. On larger motors the fit can vary
from .003 inches to .0015 inches. There are some special
purpose motors where the fit may be as much as .0018 inches,
but they will seldom be encountered.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
INDUCTION MOTOR REFERENCE GUIDE
FIELD SERVICE
2. For ease of assembly the bearing race which is stationary
relative to the load is assembled into its housing (or onto the
shaft, as the case may be) with a loose fit. It should not be
too loose however or this will tend to rotate at a slow rate in
its housing. On smaller frame sizes the fit of the race in its
housing can vary from .001 inches to .0013 inches. On
some special purpose motors the fit may be as high as .0035
inches.
3. The internal clearance in a bearing is very important because
the loss of this clearance will cause a bearing to bind and fail
almost immediately. Usually the shaft and inner race of the
bearing will attain a higher temperature than the outer race
and therefore will expand more. The outer race, however,
may be somewhat constrained by its housing, causing the
clearances in the bearing to be reduced from their original
value, when the motor reaches operating temperatures.
To reduce the possibility of a bearing losing internal clearance
during operation the bearings used in TECO-Westinghouse
industrial motors have larger internal clearances than do
standard “off the shelf” bearing of the same type and size.
Care should be exercised to insure that a bearing with the
proper fit is used whenever a replacement is made in the field.
4. Improper fits caused by incorrect dimensions, or out of
round or distorted shaft and housing fits can all cause
premature bearing
failures.
5 – INSTALLATION DAMAGE
Damage during installation is usually the result of carelessness
or ignorance. Such practices as pressing a bearing on a shaft by
pushing on the outer race or allowing the bearing to take the
thrust when a coupling is pressed on to a shaft can “brinell” the
bearing races. Bearing and couplings are installed at the factory
by preheating them and shrinking them into place, thereby
reducing the possibility of installation damage. Preheating is
usually done in a hot oil bath heated to a temperature
somewhat below the flash point of oil.
7 – CORROSION
Corrosion resulting from moisture getting into the bearings, or
from prolonged storage in an area of high humidity will cause a
premature bearing failure. The rust will cause the balls and races
to become rough and pitted. Most users will exercise care to
prevent water from getting into bearings while a motor is in
use. However, few of them take adequate measures to protect
the bearings during prolongs storage of the motors. The motors
should be kept warm and dry and the rotating element turned
over periodically to maintain film of lubricant on the bearing
surfaces.
8 – ELECTRIC CURRENT
Bearing failures due to passage of electric current through
the bearings or to defective or faulty material in the bearings
are very rare. It will suffice to point out that such failures have
occurred and the service of an experienced motor or bearing
engineer are usually required to diagnose this type of trouble
and to recommend remedial action.
CONCLUSION:
The foregoing discussion demonstrates the importance of
having the correct bearing, properly fitted and installed, and
correctly applied, to insure long trouble free operation. Each of
the causes of bearing malfunction can leave distinctive marks
and wear patterns which are quite revealing to the eye of the
experienced bearing engineer. Unfortunately, when a failure
does occur, the bearing is usually so badly damaged that these
signs are obliterated. For this reason, examination of a bearing
with incipient failure is usually much more revealing than
examination of a bearing which has sustained severe damage.
6 – VIBRATION BRINELLING
If a motor equipped with ball or roller bearing is subjected
to vibration over a prolonged period of time while it is not
operating the movement can wear indention’s in the races
where the balls or rollers are touching. This type of damage has
occurred where motors are transported over long distances
and the rotating assembly has not been restrained to prevent
movement. One of the reasons for installing a pre-loading
spring in one end of a motor is to prevent this type of damage.
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 27
INDUCTION MOTOR REFERENCE GUIDE
FIELD SERVICE
F. MOTOR BURNED OUT
A motor winding might burn out for many reasons each having
a more or less typical appearance as follows.
CASE 1: In a three phase motor a winding “burn out” due to a
defect in workmanship or material would appear as a
very localized burned spot in the failed winding and
could be easily recognized. It might be a short circuit
between the turns of wire in the coil or between the
phases or even to the iron of the stator through
ruptured insulation.
CASE 2: On the other hand, when there is a complete “roast
out” of the whole winding, all three phases of the
winding would be blackened uniformly. This would not
be due to a defect but it would be due to the failure of
the control system to shut off the power to an
overburdened motor. This overload might result from
some material being caught in the machine.
CASE 3: A single phase failure would be due to the loss of
one phase from the power supply. This could be the
result of:
• One fuse opened.
• One contactor of the starter opened (burned off or
poor contact).
• One line of the incoming power line opened.
• One connection in the conduit box opened.
Assuming that the motor has started and is properly running
under load from a three phase circuit – if one of the above
situations occurs the motor will then operate on only one
phase. This phase will pull more current in order to try to carry
the entire three phase load and in doing so will exceed its
capacity.
Normally the overload protection in the starter should
disconnect the motor but if it does not then the motor will
continue to run and the working phase will become hotter and
hotter until eventually the winding burns out.
Examination of the incoming circuitry will usually prove that
one of the four reasons listed above can be blamed for the open
circuit which caused the single phase failure. Obviously the
motor manufacturer is exonerated.
D - 28
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
USEFUL INFORMATION
• The front end of the motor is the end opposite the shaft
extension.
• The location of the conduit box should always be referred to
with reference to the front end of the motor.
• Direction of rotation, i.e., clockwise (CW) or counter
clockwise (CCW) is always when facing the front end of
the motor.
• Starting torque is the turning effort that the motor can exert
at standstill with voltage applied. It is expressed in percent
of full load strength.
• Inrush is a measure of current (or kVA) drawn from the line
at standstill when voltage is applied. Also called starting
current or kVA, it usually runs 5 to 6 times full load
nameplate values for the conventional NEMA Design B or C
motors when full voltage is applied.
INDUCTION MOTOR REFERENCE GUIDE
RE-LUBRICATION GUIDELINES
1.
Frame 143T-256T: Double shielded and pre-lubricated ball-bearing motors without grease fittings and don’t need re-lubrication,
except on Advantage Plus products which have re-greasable features.
2.
Frames 280TS, 320 and larger: Motors having grease fittings and grease discharge devices at brackets. It is necessary to re-lubricate
anti-friction bearing motors periodically, depending on size and type of service. See Table 1 to provide maximum bearing life.
Excessive or too frequent lubrication may damage the motor.
* Motors are shipped with grease for initial running however it is a good idea to add grease when the motor is first put into service,
follow table 1 for the recommended amount.
GREASE TYPE:
Mobil Polyrex EM (unless otherwise specified).
GREASE QUANTITY:
The amount of grease to add per replenishment is dependent on the size of the bearing. The following table
(Table 1) will provide two different quantities; “G” will provide the quantity required to re-lubricate the bearing
sufficiently for the interval time found in Table 2; while the second quantity “Full Qty” is the amount required
to completely fill the bearing with new grease forcing the old grease out the exit tube. Adding the “Full Qty”
amount is time consuming and requires ideal conditions; old dried up grease can potentially block the exit
tube leading to over greased bearings and other undesirable results. For general applications the “G” quantity
is sufficient, less time consuming and has lower risk of over greased bearings. The “G” amount is based on the
formula G=DxBx0.005 and is widely used in our industry.
Table 1
2 SERIES
3 SERIES
BEARING NUMBER
d
(mm)
D
(mm)
B
(mm)
G
(grams)
Full Quantity
(grams)
BEARING NUMBER
d
(mm)
D
(mm)
B
(mm)
G
(grams)
Full Quantity
(grams)
NU205/6205
NU206/6206
NU207/6207
NU208/6208
NU209/6209
NU210/6210
NU211/6211
NU212/6212
NU213/6213
NU214/6214
NU215/6215
NU216/6216
NU217/6217
NU218/6218
NU219/6219
NU220/6220
NU221/6221
NU222/6222
NU224/6224
NU226/6226
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
120
130
52
62
72
80
85
90
100
110
120
125
130
140
150
160
170
180
190
200
215
230
15
16
17
18
19
20
21
22
23
24
25
26
28
30
32
34
36
38
40
40
4
5
6
7
8
9
11
12
14
15
16
18
21
24
27
31
34
38
43
46
15
15
15
20
25
30
35
40
50
50
60
60
80
80
90
100
110
120
120
140
NU305/6305
NU306/6306
NU307/6307
NU308/6308
NU309/6309
NU310/6310
NU311/6311
NU312/6312
NU313/6313
NU314/6314
NU315/6315
NU316/6316
NU317/6317
NU318/6318
NU319/6319
NU320/6320
NU321/6321
NU322/6322
NU324/6324
NU326/6326
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
120
130
62
72
80
90
100
110
120
130
140
150
160
170
180
190
200
215
225
240
260
280
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
50
55
58
5
7
8
10
13
15
17
20
23
26
30
33
37
41
45
51
55
60
72
81
17
25
25
30
35
40
50
60
80
80
100
100
120
120
140
160
190
220
270
300
PROCEDURE:
•
•
•
•
Clean grease zerk and grease gun tip.
Remove exit tube plug to allow old grease to drain.
Add grease slowly with motor running, adding amount determined in Table 1.
Allow one hour for old grease to run out, then reinstall exit tube plug.
*
make sure grease gun is calibrated (one pump of gun should be approximately one gram of grease)
d = Bore (mm)
D = OD (mm)
B = Width (mm)
G = Grease Quantity (g)
G = D * B * 0.005
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 29
INDUCTION MOTOR REFERENCE GUIDE
RE-LUBRICATION GUIDELINES
INTERVALS:
Lubrication intervals are dependent on temperature, environment, rotational speed and load conditions; therefore it is
difficult to be precise about replenishment intervals. However, for common applications the periods shown in Table 2
may be used as a guide. For smaller bearings not listed in Table 2 use the maximum interval shown for rated speed.
Table 2
BEARING NUMBER
6210
12
13
14
15
16
17
18
20
22
24
26
28
30
32
34
36
38
600 RPM
BEARING NUMBER
NU214
15
16
17
18
20
22
24
26
28
30
32
34
36
38
40
44
48
600 RPM
BEARING NUMBER
22220
22
24
26
28
30
32
34
36
38
40
44
48
600 RPM
720 RPM
750 RPM
900 RPM
1000 RPM
1200 RPM
1500 RPM
1800 RPM
62XX
63XX
72XX
73XX
3600 RPM
2000 Hours
1000 Hours
720 Hours
2000 Hours
3000 Hours
1500 Hours
2000 Hours
1000 Hours
500 Hours
1500 Hours
2000 Hours
720 RPM
750 RPM
900 RPM
1000 Hours
1000 RPM
1200 RPM
NU2XX
NU3XX
1500 RPM
1800 RPM
2000 Hours
1500 Hours
3000 Hours
1000 Hours
2000 Hours
500 Hours
2000 Hours
1000 Hours
2000 Hours
1000 Hours
1000 Hours
720 RPM
750 RPM
900 RPM
1000 RPM
222XX
223XX
D - 30
3000 RPM
1200 RPM
500 Hours
1000 Hours
300 Hours
500 Hours
500 Hours
300 Hours
300 Hours
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
1500 RPM
1800 RPM
300 Hours
INDUCTION MOTOR REFERENCE GUIDE
USEFUL FORMULAS
kW
=
HP x .746
Torque in lb-ft
=
HP x 5250
RPM
Motor Synchronous Speed in RPM
=
120 x Hz
Number of Poles
Three Phase Full-Load Amp
=
Rated Motor kVA
=
HP (.746)
Efficiency x Power Factor
kW Loss
=
HP (.746) (1.0 – Efficiency)
Efficiency
Wk2 Referred to Motor Shaft Speed
=
Machine RPM
[Driven Machine Wk (DrivenMotor
) ] + Gear Wk
RPM
Accelerating Time
=
.462 (Wk2 of Motor and Load) RPM2
Motor rated kW x 106 x per-unit Effective Accelerating Torque
kVA Inrush
=
Percent Inrush x rate kVA
Approximate Voltage Drop (%)
=
Motor kVA Inrush x Transformer Impedance (normally 5% to 7%)
Transformer kVA
Stored Kinetic Energy in kW-sec
=
2.31 x (total Wk2) x RPM2 x 10-7
Inertia Constant (H) in Seconds
=
Stored Kinetic Energy in kW Seconds
HP (.746)
FL Amps
=
HP x 746
Eff. x PF x √3 x E
FL Amps
=
HP x 746
Eff. x PF x E
kVA Input
=
E x I x √3
1000
kVA Input
=
E x I
1000
kW Input
=
kVA Input x P.F.
HP Output
=
kW Input x Eff.
746
HP Output
=
Torque x RPM
5250
Power Factor
=
kW Input
kVA Input
HP x .746
Efficiency
Power Factor
1.732 x E x
x
100
100
2
2
2 at Motor Speed
for 3 Phase Motors
for Single Phase Motors
for 3 Phase Motors
for Single Phase Motors
Note: E is voltage, I is current, PF is power factor, Eff. is efficiency
Induction Motor Reference Guide
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
D - 31
NOTES
Notes
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
CONTACT INFORMATION
TWMI CANADA WIDE CONTACT INFORMATION
Have a question or comment for us? Maybe you need some technical or sales assistance? Feel free to call the location nearest you.
LOCATION
CONTACT INFO
CALGARY
TECO-Westinghouse Motors (Canada) Inc.
9128 - 52 Street S.E.
Calgary, Alberta T2C 5A9
24 HR Emergency Ph: (403) 473-5057
Phone: (403) 640 -2063
Fax: (403) 640-2075
CAMBRIDGE
TECO-Westinghouse Motors (Canada) Inc.
1165 Franklin Blvd., Unit A - C
Cambridge, Ontario N1R 8E1
24 HR Emergency Ph: (519) 498-1806
Phone: (519) 624-1616
Fax: (519) 624-1557
Toll Free: 800-268-4770
LOCATION
CONTACT INFO
EDMONTON
TECO-Westinghouse Motors (Canada) Inc.
18060 - 109 Avenue
Edmonton, Alberta T5S 2K2
Phone: (780) 444-8933
Fax: (780) 486-4575
24 HR Emergency Ph: (780) 994-8964
Toll Free: 800-661-4023
Fax Toll Free: 888-873-8964
LACHINE
TECO-Westinghouse Motors (Canada) Inc.
1810 - 55 Avenue
Lachine, Quebec H8T 3J5
Phone: 1-800-268-4770
24 HR Emergency Pager: (514) 242-3179
Toll Free Ph: 1-800-268-4770
Toll Free Fax: 866-309-8964
TWMI CANADA 24 HOUR EMERGENCY PAGING SERVICE
Troubles happen at the worst of times. No worries, TWMI’s highly trained staff is here to help you out. If you have an emergency, feel
free to contact us and let us help you to get back up and running as quick as possible.
Our technicians are on call 24 hours a day to provide service and solutions to your technical needs.
NOTE:
LOCATION
EMERGENCY PAGING NUMBER
EDMONTON & NORTHERN ALBERTA SERVICE
(780) 994-8964
CALGARY & SOUTHERN ALBERTA SERVICE
(403) 473-5057
ONTARIO SERVICE
(519) 498-1806
QUEBEC SERVICE
(514) 242-3179
(1) $150 After Hour Charge Monday - Sunday
(2) $225 After Hour Charge All Statutory Holidays
(3) Rates are based upon 2 hour Call-out
Contact Information
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
Contact
NOTES
Notes
For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023
WEST
1-800-661-4023
tecowestinghouse.ca
EAST
1-800-268-4770
Download