Sentry technical hotline +44 (0)1268 563720 Time Delay Switches Consumer Unit Cable Kits 291 circuit protection Accessories ONE Module Mid-Trip Off PUSH LEVER UP TO SWITCH ON RCBO TEST BUTTON • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected. Pantone Black This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice. TEST BUTTON On MCB RCD Pantone 102 Pantone Blue?? PUSH LEVER UP TO SWITCH ON Pantone 355 WARNING SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on". Pantone 485 ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320 C Busbar Shield Warning Label (Factory fitted) Ref: Ono: Our Ref: Date: Version: Size: B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit. RCD If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720. 1 2 3 4 5 6 9 10 11 12 13 14 18 19 20 21 22 17 7 8 15 16 23 24 RCD PROTECTED CIRCUITS RCD PROTECTED CIRCUITS RCD PROTECTED CIRCUITS TEST QUARTERLY TEST QUARTERLY TEST QUARTERLY 2 12 13 14 22 23 24 3 4 5 6 17 18 7 8 9 10 19 20 21 RCD TIME DELAYED 1 11 MAIN CIRCUIT NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 E Additional Information Label ADDITIONAL INFORMATION A RESETTING INSTRUCTION LABEL SWITCH F Circuit ID Labels 5544s 5562s (Cut as required) 15 U1 16 U2 U3 H Main Switches Warning Labels ON SOCKETS BASEMENT SOCKETS SECOND FLOOR SOCKETS LIGHTS BASEMENT LIGHTS GROUND FLOOR LIGHTS FIRST FLOOR LIGHTS SECOND FLOOR LIGHTS OUTSIDE LIGHTS RING CIRCUIT BASEMENT SOCKETS GROUND FLOOR RING CIRCUIT GROUND FLOOR SOCKETS FIRST FLOOR RING CIRCUIT FIRST FLOOR RING CIRCUIT SECOND FLOOR RING CIRCUIT KITCHEN RING CIRCUIT WATER HEATER WATER HEATER CENTRAL HEATING STORAGE STORAGE HEATER HEATER SHOWER SHOWER FREEZER FRIDGE COOKER COMPUTER SMOKE ALARM CLEAN EARTH SMOKE ALARM SOCKETS KITCHEN SOCKETS GARAGE SOCKETS LIGHTS GARAGE LIGHTS SECURITY OUT ALARM BUILDING WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER OFF MK SENTRY CONSUMER UNIT ON IMPORTANT ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3 TO BS EN 60439-3 220-250V 50Hz a.c. 220-250V 50Hz a.c. SECURITY ALARM RATED CURRENT MUST NOT EXCEED 63A MAX RATED CURRENT MUST NOT EXCEED 100A MAX DOOR BELL 4 module unit WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER 8, 12, 16 & 21 module units G Individual Circuit Labels K5563s This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved. K5597s 5650s K5545sMAG K8041s K5511s K5593s K5565s 5650s DELAY RANGE 1 - 7 MINUTES (APPROX) K5563s Split-load Kit Consists of 3 cables (2 neutral and 1 live) for use when assembling a split load arrangement. K5565s Suitable for installation in Sentry Consumer Units and two or four module enclosures. Offers time delay control for complete circuits of either tungsten or fluorescent lighting with any number of standard push switches. It can also be used to control fans in bathrooms without a window. Delay setting can be overridden by setting to ‘Perm-on’ mode, or by fitting a remote overriding switch. Switch has a switching capacity of 16A Resistive loads (upf) Fluorescent lamps uncompensated Series compensated 1300W Parallel compensated 480W CFLS 100W Max. Maximum of 9 units can be connected Incandescent lamps 2000W Neon glow lamp load (locating lamp for Push Switch) 50mA max VOLTAGE RATING: 230V 50Hz DIMENSIONS: 84 x 18 x 70mm CABLE CAPACITY: 1 x 4mm2or 2 x 1.5mm2 Multi-incomer Kit Consists of a blue flexible cable with pre-fitted terminal for the neutral return from switch or RCD to second or third neutral bar. KAX26s 5562s Extension Terminal For use when assembling a consumer unit as a distribution board. Enables direct connection of cables to the neutral bar. Consists of a 25mm2 capacity terminal with clamp screw. K8041s 5544s MCB Blank – GREY Designed to fill unused modules in Sentry Consumer Units and small enclosures. DIN-rail mounted. K5545sMAG Cover mounted blank For filling spaces in the ‘K’ series Sentry consumer unit cover, where there are unused modules. 17th Edition cable kit for switch and twin RCD arrangement Locking Device For use when locking a Sentry MCB, RCBO, RCD or switch disconnector in either the on or off position. K5511s K5567s K5593s K5590s K5568s A&D cable kit for switch plus triple RCD arrangement K5563s For use when assembling split-load arrangement. K5565s For use when assembling a consumer unit in a multi-incomer arrangement with separate supply to each incomer. These kits must be used to ensure compliance with BS EN 60439-3 BARREL LOCK AND KEY KIT Suitable for securing ‘K’ series Sentry Consumer Unit lids. Busbar 11 module. Busbar 20 module. KAX26s Busbar cover Suitable for insulating the busbars K5511s and K5590s 20 module. K5599s K5597s Consumer unit labels Additional printed and blank labels, for identifying devices and circuits on Dual & Triple RCD boards K5599s Consumer unit labels Additional printed and blank labels, for identifying devices and circuits on single RCD boards.