Sentry - Electrocomponents

advertisement
Sentry
technical hotline +44 (0)1268 563720
Time
Delay
Switches
Consumer
Unit Cable Kits
291
circuit protection
Accessories
ONE Module
Mid-Trip
Off
PUSH LEVER
UP TO
SWITCH ON
RCBO
TEST
BUTTON
• Reset the lever to the off position, if necessary.
• Push the lever up, to switch on.
• If the RCD trips again, switch off
all MCB's & switch on the RCD.
• Switch each MCB on, one at a time.
the RCD will switch off when the
faulty circuit is reconnected.
Pantone
Black
This installation, or part of it, is
protected by a device which
automatically switches off the supply
if an earth fault develops.
Test quarterly by pressing the button
marked 'T' or 'Test'. The device
should switch off the supply and
should then be switched on to restore
the supply.
If the device does not switch off the
supply when the button is pressed,
seek expert advice.
TEST BUTTON
On
MCB
RCD
Pantone
102
Pantone
Blue??
PUSH LEVER
UP TO
SWITCH ON
Pantone
355
WARNING
SENTRY CONSUMER UNIT - LABEL SHEET
Please leave any unused labels with the consumer
RESETTING INSTRUCTIONS
If a device switches 'OFF' in the event
of a fault, take the following action:
MCB / RCBO
• Check each appliance connected to
that device and remove if faulty.
• Push the lever up, to switch on.
• Under fault detection the MCB will trip to a
mid-"trip" position.
Reset MCB by switching "off", then "on".
Reset RCBO by switching to "on".
Pantone
485
ENSURE ALL TERMINAL
SCREWS ARE FULLY
TIGHTENED BEFORE
FITTING FRONT COVER
MK Electrics
22852
F641
25.03.08
v. 2
228.6 x 320
C Busbar Shield Warning Label
(Factory fitted)
Ref:
Ono:
Our Ref:
Date:
Version:
Size:
B RCD 'TEST' Label
Fit to prominent position on or near
Consumer Unit.
RCD
If any device still switches off (or if the RCD cannot be switched
on with all MCB's switched off) then call a qualified electrician,
or for general guidance, MK Technical Services on 01268 563720.
1
2
3
4
5
6
9
10
11
12
13
14
18
19
20
21
22
17
7
8
15
16
23
24
RCD
PROTECTED
CIRCUITS
RCD
PROTECTED
CIRCUITS
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
TEST QUARTERLY
TEST QUARTERLY
2
12
13
14
22
23
24
3
4
5
6
17
18
7
8
9
10
19
20
21
RCD
TIME DELAYED
1
11
MAIN
CIRCUIT
NUMBER
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E Additional Information Label
ADDITIONAL INFORMATION
A RESETTING INSTRUCTION LABEL
SWITCH
F Circuit ID Labels
5544s
5562s
(Cut as required)
15
U1
16
U2
U3
H Main Switches Warning Labels
ON
SOCKETS
BASEMENT
SOCKETS
SECOND
FLOOR
SOCKETS
LIGHTS
BASEMENT
LIGHTS
GROUND
FLOOR
LIGHTS
FIRST
FLOOR
LIGHTS
SECOND
FLOOR
LIGHTS
OUTSIDE
LIGHTS
RING
CIRCUIT
BASEMENT
SOCKETS
GROUND
FLOOR
RING
CIRCUIT
GROUND
FLOOR
SOCKETS
FIRST
FLOOR
RING
CIRCUIT
FIRST
FLOOR
RING
CIRCUIT
SECOND
FLOOR
RING
CIRCUIT
KITCHEN
RING
CIRCUIT
WATER
HEATER
WATER
HEATER
CENTRAL
HEATING
STORAGE STORAGE
HEATER
HEATER
SHOWER
SHOWER
FREEZER
FRIDGE
COOKER
COMPUTER
SMOKE
ALARM
CLEAN
EARTH
SMOKE
ALARM
SOCKETS
KITCHEN
SOCKETS
GARAGE
SOCKETS
LIGHTS
GARAGE
LIGHTS
SECURITY
OUT
ALARM
BUILDING
WARNING
DISCONNECT THE
MAINS SUPPLY
BEFORE REMOVING
THIS COVER
OFF
MK SENTRY
CONSUMER UNIT
ON
IMPORTANT
ALL MAIN SWITCHES
MUST BE SWITCHED
OFF TO COMPLETELY
DISCONNECT THE UNIT
FROM THE SUPPLY
OFF
MK SENTRY
CONSUMER UNIT
TO BS EN 60439-3
TO BS EN 60439-3
220-250V 50Hz a.c.
220-250V 50Hz a.c.
SECURITY
ALARM
RATED CURRENT
MUST NOT EXCEED
63A MAX
RATED CURRENT
MUST NOT EXCEED
100A MAX
DOOR
BELL
4 module unit
WARNING
DISCONNECT THE
MAINS SUPPLY
BEFORE REMOVING
THIS COVER
8, 12, 16 & 21 module units
G Individual Circuit Labels
K5563s
This proof has been printed on a low resolution colour proofer. Colours may vary from final print.
Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.
K5597s
5650s
K5545sMAG
K8041s
K5511s
K5593s
K5565s
5650s
DELAY RANGE
1 - 7 MINUTES (APPROX)
K5563s
Split-load Kit
Consists of 3 cables (2 neutral and 1
live) for use when assembling a split
load arrangement.
K5565s
Suitable for installation in Sentry
Consumer Units and two or four
module enclosures. Offers time delay
control for complete circuits of either
tungsten or fluorescent lighting
with any number of standard push
switches. It can also be used to
control fans in bathrooms without a
window. Delay setting can be overridden by setting to ‘Perm-on’ mode,
or by fitting a remote overriding
switch. Switch has a switching
capacity of 16A Resistive loads (upf)
Fluorescent lamps uncompensated
Series compensated 1300W
Parallel compensated 480W
CFLS 100W Max. Maximum of 9 units
can be connected
Incandescent lamps 2000W
Neon glow lamp load (locating lamp
for Push Switch) 50mA max
VOLTAGE RATING: 230V 50Hz
DIMENSIONS: 84 x 18 x 70mm
CABLE CAPACITY: 1 x 4mm2or 2 x
1.5mm2
Multi-incomer Kit
Consists of a blue flexible cable with
pre-fitted terminal for the neutral return
from switch or RCD to second or third
neutral bar.
KAX26s
5562s
Extension
Terminal
For use when assembling
a consumer unit as a
distribution board. Enables
direct connection of cables
to the neutral bar. Consists of
a 25mm2 capacity terminal
with clamp screw.
K8041s
5544s
MCB Blank – GREY
Designed to fill unused
modules in Sentry
Consumer Units and small
enclosures. DIN-rail
mounted.
K5545sMAG
Cover mounted blank
For filling spaces in the ‘K’ series
Sentry consumer unit cover, where
there are unused modules.
17th Edition cable kit for switch and
twin RCD arrangement
Locking Device
For use when locking a
Sentry MCB, RCBO, RCD or
switch disconnector in either
the on or off position.
K5511s
K5567s
K5593s
K5590s
K5568s
A&D cable kit for switch plus
triple RCD arrangement
K5563s
For use when assembling split-load
arrangement.
K5565s
For use when assembling a consumer unit in
a multi-incomer arrangement with separate
supply to each incomer.
These kits must be used to ensure
compliance with BS EN 60439-3
BARREL LOCK AND KEY KIT
Suitable for securing ‘K’ series
Sentry Consumer Unit lids.
Busbar
11 module.
Busbar
20 module.
KAX26s
Busbar cover
Suitable for insulating the busbars
K5511s and K5590s 20 module.
K5599s
K5597s
Consumer unit labels
Additional printed and blank labels,
for identifying devices and circuits on
Dual & Triple RCD boards
K5599s
Consumer unit labels
Additional printed and blank labels,
for identifying devices and circuits on
single RCD boards.
Download