EBNV.E10279 - Conduit Fittings for Use in Hazardous Locations Page 1 of 4

EBNV.E10279

Conduit Fittings for Use in Hazardous Locations

Page Bottom

Conduit Fittings for Use in Hazardous Locations

See General Information for Conduit Fittings for Use in Hazardous Locations

COOPER CROUSE-HINDS

WOLF & 7TH NORTH ST

PO BOX 4999

SYRACUSE, NY 13221 USA

Class I, Groups A, B, C and D; Class II, Groups E, F and G; Class III.

E10279

Conduit adapters , Cat Nos. REA12, -23, -34, may be followed by NQA-1, for use with 3/4, 1, 1-1/4 in. conduit sizes.

Conduit unions , Types UNF, UNY, Cat. No. UNF or UNY105, -205, -215, -305, -315, -325 with or without suffix SA or NQA-1, conduit sizes 1/2,

3/4, 1 in.

Conduit fittings for sealing , for use only with manufacturer's sealing compound "Chico A" :

Type EYS for horizontal or vertical mounting, Cat. Nos. EYS11, -21, -31, -116, -216, -316 with or without suffix S752, S753, SA or NQA-1, conduit sizes 1/2, 3/4, 1 in.

Cat. Nos. EYS-41, -51, -61, -71, -81, -416, -516, -616, -716, -816, may be followed by NQA-1, conduit sizes 1-1/4, 1-1/2, 2, 2-1/2, 3 in.

Type EYS, for vertical mounting, Cat. Nos. EYS-1, -2, -3, -16, -26, -36, with or without suffix SA, conduit sizes 1/2, 3/4, 1 in.

Conduit union box connectors, 90 degree , Type UNL, Cat. Nos. UNL-105, -125, -205, -215, with or without suffix SA or NQA-1, conduit sizes

1/2, 3/4 in.

Flexible connection fittings , Series EC, Type ECGJH; followed by -1 or -2, followed by 4 to 36 incl.; followed by S516; followed by -1; maybe followed by S371 or NQA-1, conduit sizes 1/2, 3/4 in.

Series EC, Types ECLK, ECK, ECL; followed by -1 or -2; followed by 4 through 36 incl.; followed by S516; may be followed S371 or NQA-1, conduit sizes 1/2 and 3/4 in.

Series EC, Type ECGJH; followed by 1 or 2; followed by 4 through 36 incl.; followed by S516, may be followed by NQA-1, conduit sizes 1/2 and 3/4 in.

Series EC, Types ECGJH, ECLK, conduit sizes 1/2, 3/4 in., with flexible lengths of 4 through 36 in. incl. Inside radius of bends should be not less than 10 in. for the 1/2 in. size, 12 in. for the 3/4 in. size.

Conduit elbows, (45-deg and 90-deg bend) , Series EL, Cat. Nos. EL-1, -2, -19, -29,-195, -196, -295, -296, with or without suffix SA; Cat No.

EL-3, -39, -395, -396, may be followed by SA or NQA-1, conduit sizes 1/2, 3/4, 1 in.

Conduit reducers , Cat. Nos. RE-21, -31, -32, -41, -42, -43, -51, -52, -53, -54 may be followed by BR, SA or NQA-1, conduit sizes 1/2 to 1-1/4 in.; Cat. Nos. REC-21, -21SA, -31, -31SA, may be followed by NQA-1, conduit sizes 1/2 to 1 in.

Cat. Nos. RE61, -62, -63, -64, -65, -73, -74, -75, -76, -83, -84, -85, -86, -87, -96, -97, -98, -106, -107, -108, -109 may be followed by -SA, -

SBZ, or NQA-1, conduit sizes 1/2 to 4 in.

Conduit sealing fitting modification kit , "Chico SpeedSeal II" compound for use only with Cat. Nos. EYS, EYD, sized 1/2 in. to 4 in.

Conduit T-Fittings , Cat. Nos. ET followed by 218, 228 or 328, may be followed by NQA-1, side conduit size 1/2 in., 3/4 in. and 3/4 in. respectively.

Upper conduit size 3/4 in., 3/4 in. and 1 in. respectively. mhtml:file://C:\Users\FB2E4\Documents\Charlie saved\Technical\UL Listings\EBNV_E...

11/15/2012

EBNV.E10279 - Conduit Fittings for Use in Hazardous Locations Page 2 of 4

Class I, Groups B, C and D; Class II, Groups E, F and G; Class III.

Conduit fittings for sealing, for use only with manufacturer's sealing compound "Chico A" , Types EYD, EYDX, for vertical mounting only;

Types EYS, EYSX, for horizontal or vertical mounting.

Cat. Nos. EYD-91, -101 may be followed by suffix S752, S753 or NQA-1, conduit sizes 3-1/2, 4 in.

Cat. Nos. EYS-1, -2, -3, -16, -26, -36 with or without suffix SA, SBZ or NQA-1, conduit sizes 1/2, 3/4, 1 in.

Cat. Nos. EYS-11, -21, -31, -116, -216, -316 with or without suffix S752, -S753, -SA, -SBZ, or NQA-1, conduit sizes 1/2, 3/4, 1 in.

Cat. Nos. EYD-11, -21, -31, -41, -51, -61, -71, -81, -91, -101, -116, -216, -316, -416, -516, -616, -716, -816, -916, -1016, may be followed by

NQA-1, conduit sizes 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2, 4 in.

Cat. Nos. EYDX, EYSX followed by -11, -21, -31, -41, -51, -61, with or without suffix 6, -S752, -S753, conduit sizes 1/2 to 1-1/2 incl.

Sealing cover , Model GUA062-GB and Series GUA bodies for use with manufacturers sealing compound "Chico SpeedSeal".

Conduit unions , Types UNF, UNY, Cat. Nos. UNF, UNY followed by 105, 205, 215, 305, 315, 325, with or without suffix BR, SBZ or NQA-1, conduit sizes 1/2, 3/4, 1 in.

Types UNF, UNY, Cat. No. UNF or UNY-406, -506, -606, -706, -806, -905, -1005 may be followed by SA, SBZ or NQA-1, conduit sizes 1-1/4, 1-1/2,

2, 3, 3-1/2, 4 in.

Conduit union box connectors, 90 degrees , Type UNL, Cat. Nos. UNL-105, -125, -205, -215 with or without suffix BR, SBZ or NQA-1, conduit sizes 1/2, 3/4 in.

Conduit fittings for draining or venting , Type ECD, Cat. Nos. ECD-16, -17, ECD16/17, may be followed by NQA-1, conduit size 1/2 in.

Conduit fittings for draining or venting , Types ECD1-N4B, ECD1-N4D, may be followed by NQA-1, conduit size 1/2 in.

Class I, Groups C and D; Class II, Groups E, F and G; Class III.

Conduit fittings for sealing , for use only with manufacturer's sealing compound, "Chico A":

Type EZS, Cat. Nos. EZS-1 to -8 incl., -16, -26, -36, -46, -56, -66, -76, -86, may be followed by NQA-1, conduit sizes 1/2 to 6 in. incl.

Type EYDX, for vertical mounting only, Cat. No. EYDX followed by -1, -2, -3, -4, -5, -6, -7, -8, with or without suffix -6, -S752, -S753 , -SA or -

NQA-1, conduit sizes 1/2 to 1-1/2 incl.

Type EYS, for vertical and horizontal mounting (face up only), Cat. Nos. EYS-4 to -12 incl., -46, -56, -66, -76, -86, -96, -012, -014, -106, -0126 with or without suffix S752, S753, SA, SBZ or NQA-1, conduit sizes 1-1/4 to 5 in. incl.

Types EYS-014, -0146 with or without suffix S752, S753 or SBZ, conduit size 6 in.

Type EYS (90-deg bend), for vertical mounting, Cat. No. EYS-29, may be followed by NQA-1, conduit size 3/4 in.

Type EYSX, for vertical and horizontal mounting, Cat. No. EYSX followed by -1, -2, -3, -4, -5, -6, -7, -8, with or without suffix -6, -S752, -S753, -

SA or NQA-1, conduit sizes 1/2 to 1-1/2 incl.

Type EZD, for vertical mounting, Cat. Nos. EZD-10, -20, -30, -40, -50, -60 with or without suffix SA or NQA-1, conduit sizes 1/2 to 2 in. incl., with integral drain fittings, Cat. Nos. EZD-111, -211, -311, -411, -511, -611 with or without suffix SA or NQA-1, conduit sizes 1/2 to 2 in. incl.

Sealing hubs , for use with "Chico A" sealing compound:

Cat. Nos. ES31, -32, -53, -64, -65, may be followed by NQA-1, conduit sizes 1/2, 3/4, 1, 1-1/4, 1-1/2 in. For vertical mounting only in the bottom of an enclosure.

Conduit sealing fitting modification kit , chico SpeedSeal compound for use only with Cat. Nos. EYS, EYD sizes 1/2 to 2 in.

Sealing hubs , for use with TSC epoxy sealing compound:

Cat. Nos. ES-31, -32, -53, -64, -65, -76, -108, -01210, -014012, may be followed by NQA-1, conduit sizes 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 3, 4, 5.

Conduit elbows (45-deg and 90-deg bend) , Series EL, Cat. No. EL-4, -5, -6, -7, -8, -9, -10, -49, -59, -69, -79, -495, -496 with or without suffix SA or NQA-1, conduit sizes 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2, 4 in.

Conduit fittings for draining or venting , Type ECD, Cat. Nos. ECD-11, -13, may be followed by NQA-1, conduit size 1/2 in. mhtml:file://C:\Users\FB2E4\Documents\Charlie saved\Technical\UL Listings\EBNV_E...

11/15/2012

EBNV.E10279 - Conduit Fittings for Use in Hazardous Locations Page 3 of 4

Type ECDE, Cat. No. ECDE-15, may be followed by NQA-1, conduit size 1/2 in.

Short-radius capped elbows (90-deg bend) , Cat. Nos. LBY-15, -25, -35, -45, -55 with or without suffix SA, SBZ or NQA-1, conduit sizes 1/2,

3/4, 1, 1-1/4, 1-1/2 in.

Conduit unions , Types UNF, UNY, Cat. Nos. UNF or UNY-405, -505, -605, -705, -805, with or without suffix SA, SBZ or NQA-1, conduit sizes 1-

1/4 to 3 in. incl.

Flexible connection fittings , Series EC, Type ECGJH; followed by -3, -4, -5 or -6; followed by 4 through 36 incl.; followed by S516; followed by -

1; may be followed by S371 or NQA-1, conduit size, 1, 1-1/4, 1-1/2, 2 in.

Series EC, Types ECLK, ECK and ECL; followed by -3; followed by 4 through 36 incl.; followed by S516; may be followed by S371 or NQA-1, conduit size 1 in.

Series EC, Type ECGJH; followed by 3, 4, 5 or 6; followed by 4 through 36 incl.; followed by S516, may be followed by NQA-1, conduit sizes 1, 1-

1/4, 1-1/2 and 2 in.

Series EC, Types ECGJH, ECK, ECLK, conduit size, 1, 1-1/4, 1-1/2 in., with flexible length 4 to 36 in. incl. Inside radius of bend should be not less than 14 in. for the 1, 1-1/4 in. sizes.

Conduit expansion unions , Cat. No. UNF, UNFL, UNY, UNYL-17, -27 or -37, may be followed by NQA-1, conduit sizes 1/2 to 1 in.

Sealing covers , Models GUA -042, -062, -072, -092 and Series GUA bodies for use with manufacturers sealing compound "Chico SpeedSeal".

Class I, Groups C and D; Class II, Groups F and G; Class III.

Conduit fittings for draining and venting , Type ECD, Cat. Nos. ECD-15, -18, may be followed by NQA-1, conduit size 1/2 in.

Conduit fittings for sealing , for use only with Manufacturer's " sealing compound" Chico A":

Type EYD for vertical mounting and provided with drain fitting Cat. Nos. EYD-1 to -9 incl., -16, -26, -36, -46, -56, -66, -76, -86, -96, conduit sizes

1/2 to 3-1/2 in. incl., with or without suffix BR, BZ, SA, SBZ or NQA-1; Cat. Nos. EYD-10, -106, may be followed by NQA-1, conduit size 4 in.

Class I, Groups C and D; Class II, Groups E, F and G.

Conduit reducers , Cat. Nos. RE01210, -01412 may be followed by -SA, -SBZ or NQA-1, conduit sizes 5 to 6 in. incl.

Cat. Nos. REC32, -32SA, -42, -42SA, -43, -43SA, -52, -52SA, -53, -53SA, -54, -54SA, -75, -86, -86SA, -97, -108, -602, -602SA, -603, -603SA, -

604, -604SA, -605, -605SA, -01210, may be followed by NQA-1, conduit sizes 3/4 to 5 in.

Class I, Groups C and D; Class II, Groups F and G.

Cord connectors , Cat. Nos. EBY2672, -2682, -26102, rated 20 amp, 480 v, conduit sizes.

.Class I, Groups B, C and D; Class II, Groups F and G ; Class III.

Cord connectors , Cat. Nos. EBY2672, -2682, -26102, rated 20 amp, 480 V followed by GB, conduit size.

Class I, Group D; Class II, Group E, F and; Class III. .

Universal type box connector conduit union , Type UNA, 1, 2, 3, 16, 26, 36, may be followed by NQA-1, conduit sizes 1/2 to 1 in.

Sealing hub , for use with "Chico A" sealing compound:

Cat. Nos. ES76, -108, -01210, -014012, may be followed by NQA-1, conduit sizes 3, 4, 5 in. For vertical mounting only in the bottom of an enclosure.

Last Updated on 2011-07-15

Questions? Print this page Notice of Disclaimer Page Top

© 2012 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up

Service. Always look for the Mark on the product. mhtml:file://C:\Users\FB2E4\Documents\Charlie saved\Technical\UL Listings\EBNV_E...

11/15/2012

EBNV.E10279 - Conduit Fittings for Use in Hazardous Locations Page 4 of 4

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide

Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC". mhtml:file://C:\Users\FB2E4\Documents\Charlie saved\Technical\UL Listings\EBNV_E...

11/15/2012

Download