CHILLEDWATERCASSETTEFANCOIL CWC ChilledWaterCassetteFanCoil Unsurpassedflexibilityandquality Thechilledwatercassetteisdesignedtooptimiseenergyefficiencyandairdistributionperformance.Itcombinesunsurpassed flexibilityandqualitywithquietoperationandeffectivecontrol. Improvedcomfort TheCWCchilledwatercassetteprovidesaversatilesolution forawiderangeofcommercial,retailandleisure applicationswheremaintainingcomfortabletemperature controloftheenvironmentisessential.Withadiverse choiceofoptionsintermsofheating,coolingandairflow, theoptimummodelcanbeselected. Unobtrusivedesign Aneat,compactunit,thecassetteisbothsmartand unobtrusive.Thesmallersizedmodelmeasuresjust 600mmsquareandwillfitintothespaceofastandard ceilingtile.Theelegantairinletgrilleblendsaestheticallywith anyroomdecor.ThelowprofileCWCislightandeasyto install.Thesmallchassisfitsnearlywithstandardceilingtiles andissimpletoinstallwhereveritisneeded. Evenairdistributionthroughouttheroom Thespecialdesignofthediffuserensuresrapidblendingof thesupplyandroomair.Conditionedairisdirectedalong theceilingthenevenlydistributedthroughouttheroom. Returnairentersthecassetteunitthroughalargegrille.Itis thencleanedbyaneasilyremovable,washablesynthetic filter,treatedandrecirculated. Serviceability Allthekeycomponents(motor,fans,drainpump)are accessiblefromthebottombysimplyremovingthegrille. Thesecomponentscanberemovedwithoutdisturbingthe othercomponentsoranysurroundingceilingtiles. ChilledWaterCassetteFanCoil Benefits -Lowenergyconsumption -Improvedcomfort -Unobtrusivedesign -Evenairdistribution -Quietoperation -Highserviceability -Suitableforvariousheatingsources Variousheatsources Thechilledwatercassetteisavailableinthreeversions: Chilledwatercoolingonly Chilledwatercoolingwithelectricheating Chilledwatercoolingwithhotwaterheating Allunitshaveconnectionsforfreshairductsthatconsiderablyimproveindoorquality. Applications Thechilledwatercassetteoffersamodernsolutionforawidevarietyofsmallandmediumsizedcommercialandresidentialapplications.Itisideallysuitedforlargeoffices,shops, restaurantsandbars,hotelreceptions,meetingrooms,banks,laboratories,showrooms,etc. Quietoperation TheCWCisavailableinsixsizessuitableforawiderangeofapplications,withairflowsfrom 100to443l/s.Theunitsofferanultra-low-noisesolutionforapplicationswherealownoise levelisthemostimportantselectioncriteria. Leadingreferences: BTSports Cineworld JohnLewis Partnership SuperdryStores UniversityofBristol CWCcontrol Controls Basiccontrol Withthisoptionathree-speedswitchissuppliedinaseparatecontrolsboxwitha‘flyinglead’ toallowelectricalconnectionstobemadetothechilledwatercassetteunitonsite.Controlof thecoolingand/orheatingcoilsistobeprovidedbyothers.Thisoptionisnotavailablewith electricheating. Advancedcontrol ThisoptionprovidesaconfigurableJohnsonTUC03terminalunitcontrollerwhichisdesigned specificallytoprovidedirectdigitalcontroloftheunitfanspeedsandthecoolingand/or heatingcoils.Communicationoptionsareavailabletoenablethecontrollertobeintegrated intoanN2OpenorBACnet®networkofabuildingautomationsystem. Suppliedasstandardwiththisoptionare: Unitcontrollersuppliedinaseparatecontrolsboxwitha‘flyinglead’toallowcontrollerto beconnectedtothechilledwatercassetteunitonsite. 4-wayvalvesandactuatorsforfittingandwiringonsite. Wallmountedtemperaturesensor,typeTM-2140-0000 Whenitispreferabletouseadifferentmeasuringdevice,toofferadegreeofcontrolforthe roomoccupiertosetandadjust,thefollowingoptionsareavailable(allsensorsaresupplied separately): Description Wallmountedsensoronly Wallmountedsensorandadjuster Wallsensor,adjusterandfan speedcontrol Wallsensor,adjusterandfan speedcontrolwithLCDdisplay TM-2140-0000 TM-2160-0005 Itemcode TM-2140-0000 TM-2160-0005 TM-2160-0007 Localfanspeed adjustment No No 3-speedfanoverride Adjustable temp.dial No ±3°C ±3°C RS-1180-0007 3-speedfanoverride ±3°C TM-2160-0007 RS-1180-0007 CWCpossibilities&specifications Asuitablesolutionforeverysituation Possibilities: Designedtofitwithintypicalsuspendedceilinggrid Sixmodelsizes AC&ECfanmotoroptions Twophysicalsizes-nominally600mmx600mmor 900mmx900mmand300mmdeep Twocontroloptions:basicandadvanced Undertypicaloperatingconditionsupto4kWsensible cooling,11kWwaterheatingor3kWelectricheating Fourwayairdistribution,viapurposedesignedgrille Fittedwithcondensateliftpumpandwashablefilter Accesstoallcomponentsfromunderneath Heatsource: Electric Water:coolingonlyorcooling/heating(twoorfour-pipe) Freshairinletoption Thefreshairflowmustbelessthan10%ofthetotalairflowtoavoidoperatingproblemsandexcessivenoise.Thefreshairis notconditionedbytheCWCunit. Supplyofconditionedairducttoanadjacentroom Thisoptionallowssupplyofasmallamountofconditionedairtoaroomlocatedclosetothecassettethroughanairduct (customer-supplied).Ifthisoptionisused,theoutletgrillecorrespondingtotheductpositionmustbeclosed,usingtheairsupply outletobstructionkitavailable.Thekitcannotbeusedinunitsequippedwithelectricheater.Ductlengthsshouldbeminimal. Drainpump Thehighperformanceautonomouscondensatedrainpumpisencasedinaspecialsound-insulatingmaterialforimprovedfast andquietcondensateremoval. Controlbox Allunitsareequippedwithacontrolboxcontainingtheterminalblocks.Theboxispositionedontheoutsideoftheunit.The additionalbasicoradvancedcontrolsboxissuppliedloose. Filter Thestandardfilterfortherangehasapleatedfiltersurface,resultingina87%largersurfacethanaconventionalfilter.Theair flowperunitareaislower,resultinginlowerpressuredropandreducednoiselevel.Furthermoretheaverageintervalbetween filtercleaningisthreetimeslongerthanstandardfilters.ThefiltermaterialispolypropyleneandthegradeisEU1. CWCtechnicaldata CWCelectric&waterunits Coolingonly ModelType/Code Speed-Motortype Speed-Motortype AirVolume TotalCooling SensibleCooling LPHWHeating NoiseRating PowerInput-AC* PowerInput-EC* Current-AC* Current-EC* Grillesize Weight CWC-004-2P* *=AC *=EC l/s kW kW kW NR W W A A mm kg 100/125/183 0.94/1.09/1.53 0.88/1.02/1.42 18/23/33 58 23 0,27 0,19 18 CWC-008-2P* CWC-010-2P* CWC-012-2P* CWC-016-2P* (*addsuffixforACorECtypemotorsasrequired) 1/2/3 2v/6v/10v 89/140/204 134/173/249 147/199/271 139/229/321 1.34/2.09/2.95 1.95/2.52/3.45 2.35/3.19/4.42 2.58/3.85/5.13 1.05/1.63/2.31 1.55/2.00/2.74 1.92/2.60/3.56 1.97/3.01/4.04 n/a 18/30/38 28/34/43 20/26/33 23/32/39 54 94 63 85 33 57 25 46 0,24 0,41 0.30 0,46 0,27 0,46 0,23 0.40 720x720 960x960 20 20 42 45 CWC-020-2P* 166/299/443 2.91/4.75/6.33 2.22/3.68/4.90 26/38/45 123 115 0,63 0,89 45 Coolingonlywithelectricalheating ModelType/Code ElectricHeating CurrentInput CWC-004-2PE* kW A CWC-008-2PE* CWC-010-2PE* CWC-012-2PE* CWC-016-2PE* (*addsuffixforACorECtypemotorsasrequired) 2,5 2,5 3 3 9,4 9,4 11,3 11,3 1,5 5,9 CWC-020-2PE* 3 11,3 (Onlyavailablewhencombinedwithadvancedcontrolpackage) Heating&Cooling ModelType/Code Speed-Motortype Speed-Motortype AirVolume TotalCooling SensibleCooling LPHWHeating NoiseRating PowerInput-AC* PowerInput-EC* Current-AC* Current-EC* Grillesize Weight CWC-004-4P* *=AC *=EC l/s kW kW kW NR W W A A mm kg 100/125/183 1.01/1.14/1.54 0.93/1.08/1.45 1.24/1.44/1.90 18/23/33 58 23 0,27 0,19 18 CWC-008-4P* CWC-010-4P* CWC-016-4P* CWC-020-4P* (*addsuffixforACorECtypemotorsasrequired) 1/2/3 2v/6v/10v 89/140/204 134/173/249 139/229/321 166/299/443 1.40/1.88/2.49 1.51/2.02/2.61 1.84/3.41/4.66 2.41/4.85/5.73 1.10/1.51/2.02 1.37/1.78/2.33 1.59/2.78/3.79 2.01/3.83/4.66 3.60/5.10/6.37 5.00/5.80/6/80 6.00/8.90/11.50 7.30/11.50/16.00 19/31/40 28/34/43 23/32/39 26/38/45 54 94 85 123 32 57 46 115 0,24 0,41 0,46 0,63 0,29 0,46 0.40 0,89 720x720 960x960 20 20 45 45 -Chilledwatercoolingbasedon7/12°C,withairentry23°Cdb/17°Cwb -LPHWheatingbasedon70/60°C,withairentry20°C -NRvaluesbasedonanhypotheticalsoundattenutaionfortheroomof-9dB(A) CWCdimensionalsketch CWCelectric&water CWC004/008/010 CWC012/016/020 A 569 822 B 298 302 C 400 620 D 720 960 E 515 812 F 550 595 G 40 40 H 40 74 Heatingandcoolingconnections Thecoolingandheatingcoilsareintegrated(factory-mounted)intheunit. Thesmallersizedunitshave3/4"diametercoolingpipeconnectionsand1/2"diameter heatingpipeconnections. Thelargersizedunitshave1"diametercoolingpipeconnectionsand3/4"diameter heatingpipeconnections. BiddleAirSystemsLimited St.Mary’sRoad,Nuneaton WarwickshireCV115AU T+44(0)2476384233 Esales@biddle-air.co.uk Iwww.biddle-air.co.uk