DUAL-TEC™ WALL-MOUNT™ Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D28A/L to D60A/L 1-Stage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC™ Wall Mount™ Air Conditioners with -48VDC Blower Motor and DC Voltage Free Cooling Economizer are designed for maximum indoor cooling at the most efficient operating cost for year-round operation in the demanding equipment shelter environment. The DUAL-TEC™ units operate on both AC and -48VDC positive ground power under normal power supply conditions. If there is loss of AC power supply (shore &/or back-up generator) the DUAL-TEC™ will continue to operate as free-cooling or ventilation system using the shelter’s DC power. The DUAL-TEC™ indoor blower and economizer operate from -48VDC and no inverter is required. The DUAL-TEC™ units will supply up to 100% of rated cooling airflow in free cooling mode with the ability to exhaust the same amount through the unit itself without any additional relief openings in the shelter. DUAL-TEC™ Special Features Brushless -48VDC Indoor Blower Motor: 100% Free Cooling Unit Ventilator: DC Polarity Monitor: PLC Logic Board: Features low sound levels and soft-start capabilities. Soft start function helps to ensure DC power levels will not decrease on start up, and brushless design ensures low DC power noise. The motor is self-adjusting to provide the proper airflow rate without user adjustment or wiring changes. Includes diagnostics and protects critical DC components against reverse polarity and out-of-range DC power. Range is 40-60 VDC. Remote Monitoring: All units are equipped with a full-flow free cooling ventilator. The ventilator uses DC power for operation in conjunction with the -48VDC Indoor Blower during AC power loss. Modulating air intake allows precision temperature control inside the structure while maximizing energy savings. All units are equipped with a PLC Logic Board for advanced unit operation and alarm capability. The PLC Logic Board allows for “orphan mode” unit operation if communication with the LC controller is lost Bard DUAL-TEC™ Bard-Link™ web interface with use of LC Controller Standard Engineered Features — All Models Copper Tube / Aluminum Fin Coils: Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Evaporator coil constructed with hydrophilic fin stock that seals fin surface against aluminum oxide formation, is resistant to mold and mildew growth (tested to ASTM D3273, no growth) and reduces beading of condensate on the fin surface. Optional phenolic-coated coils are also available. Extreme Outdoor Temperature Rating: PTCR Motor Starting Device: Standard on 1-phase models, increases compressor motor starting torque 2-3 times. Optional factory or field installed hard start kit available, replaces PTCR device. Galvanized 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03. D36A/L & D42A/L units are rated up to 131°F outdoor ambient temperature Foil Faced Insulation: operation. Standard on all units. Air Conditioner Compressor: Scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. R-410A Refrigerant: Designed with R-410A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements. • • • • Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Liquid Line Filter Drier: Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory installed for all 2½ through 5 ton models. Two-Inch, MERV 8 Air Filters: Are standard equipment. All models include tight-sealing U-channel filter bracket to minimize air bypass around the filter. Built-In Circuit Breakers: HACR-type circuit breakers are standard for AC power supply, and DC rated circuit breaker used for -48VDC power circuit. Used with LC Series Controller High & Low Pressure Switches are Auto-Reset: Standard on all units. Built-in lock-out circuit resets from the shelter BardLink™ Controller. Provides commercial quality protection to the compressor. Refrigerant Sight Glass: Standard on all units. Standard on all units. Protects system Low Ambient Control: against moisture. Modulating LAC standard on all models. Screw-on fitting design for ease of 24V Transformer: service. 75VA with circuit breaker Complies with efficiency requirements of ASHRAE/IESNA 90.1-2013. Certified to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Fourth Edition. Commercial Product - Not intended for Residential application. Form No. S3521-516 SupersedesS3521-116 Page 1 of 10 Capacity and Efficiency Ratings — 1-Stage Compressors MODELS Cooling Capacity BTUH EER D28A D28L D36A D36L D42A D42L D48A D48L D60A D60L 28,600 36,000 41,500 47,000 57,000 11.5 11.5 11.0 10.5 10.0 Capacity is certified in accordance with ANSI/ARI Standard 390-2003. Rating conditions are 95°F (35°C) outdoor and 80°F DB/67°F WB (26.5°C / 19.5°C WB) return air. EER = Energy Efficiency Ratio (BTU / Watt Efficiency) is certified in accordance with ANSI/ARI Standard 390-2003. Includes DC watts for blower motor. Ratings are with no outside air. Performance will be affected by altitude. Electrical Ratings — 1-Stage Compressor Models MODELS Electrical Rating – 60 Hz Operating Voltage Range DC Electrical Rating Operating Voltage Range D28A2PA D28L2PA D28A2PB D28L2PB D36A2PA D36L2PA D36A2PB D36L2PB D42A2PA D42L2PA D42A2PB D42L2PB D48A2PA D48L2PA D48A2PB D48L2PB D60A2PA D60L2PA D60A2PB D60L2PB 230/208-1 230/208-3 230/208-1 230/208-3 230/208-1 230/208-3 230/208-1 230/208-3 230/208-1 230/208-3 253-197 253-197 253-197 253-197 253-197 -48VDC -48VDC -48VDC -48VDC -48VDC 40 - 60 VDC 40 - 60 VDC 40 - 60 VDC 40 - 60 VDC 40 - 60 VDC Compressor Voltage Rated Load Amps Branch Circuit Selection Current Lock Rotor Amps 230/208-1 230/208-3 230/208-1 230/208-3 230/208-1 230/208-3 230/208-1 230/208-3 230/208-1 230/208-3 8.3 / 9.3 5.4 / 6.1 11.6 / 12.9 7.4 / 8.2 15.1 / 16.7 11.5 / 12.6 16.3 / 18.2 10.1 / 11.5 21.0 / 23.8 13.9 / 15.8 12.9 8.4 16.7 10.5 18 13.5 21.8 13.8 26.3 15.8 64 58 79 73 112 88 117 83.1 134 110 Fan Motor Fan Motor – HP Volts Full Load Amps Fan – CFM 1/3 230/208-60-1 2.5 2400 1/3 230/208-60-1 2.5 2900 1/3 230/208-60-1 2.5 3300 1/3 230/208-60-1 2.5 3400 1/3 230/208-60-1 2.5 3400 3/4 -48VDC 14.0 3/4 -48VDC 14.0 3/4 -48VDC 14.0 3/4 -48VDC 14.0 3/4 -48VDC 14.0 550 565 565 630 635 DC Blower Motor Blower Motor – HP Volts Blower Motor – Full Load Amps Shipping Weight (Lbs.) Neg. 48VDC positive ground. Unit Charge Rates UNIT Std. Unit - Lbs. Dehum. Units - Lbs. D28A2P/D28L2P - DUAL-TEC™ -48VDC Right & Left Hand Free Cooling 6.3125 N/A D36A2P/D36L2P - DUAL-TEC™ -48VDC Right & Left Hand Free Cooling 9.375 N/A D42A2P/D42L2P - DUAL-TEC™ -48VDC Right & Left Hand Free Cooling 11.875 N/A D48A2P/D48L2P - DUAL-TEC™ -48VDC Right & Left Hand Free Cooling 12.00 N/A D60A2P/D60L2P - DUAL-TEC™ -48VDC Right & Left Hand Free Cooling 11.4375 N/A DC Free Cooling Unit Ventilator DC Powered Free Cooling Ventilator: The DUAL-TEC™ free cooling ventilator allows for cooling operation when outdoor temperature conditions are acceptable outside the building structure. By using a modulating motor controlled by the PLC Logic Board, the ventilator allows for filtered outdoor air to enter the structure and provide cooling with minimal energy usage. The ventilator has the following features: • Defaults to temperature only, with optional humidity sensing. • Exhaust air passage maintain a slight positive indoor air pressure. • Easily serviceable, modulating DC powered vent motor. • Large air intake passages for increased efficiency. • Advanced blade sealing for minimal air infiltration when closed. • Intake air filter. • Advanced PLC algorithmic operation. • Outdoor air temperature and enthalpy sensor. • Return air temperature sensor. Form No. S3521-516 SupersedesS3521-116 Page 2 of 10 SUMMARY ELECTRICAL RATINGS 1-Stage Compressor Models AC Power Circuit DC Positive Ground Power Circuit Rated Volts, Hertz & Phase Minimum Circuit Ampacity Maximum External Fuse or Ckt. Brkr. D28A2PA05 / D28L2PA05 208/230-60-1 26 30 10 15.6 20 12 D28A2PB06 / D28L2PB06 208/230-60-3 18 20 12 15.6 20 12 D36A2PA05 / D36L2PA05 208/230-60-1 26 40 8 15.6 20 12 D36A2PB06 / D36L2PB06 208/230-60-3 18 25 10 15.6 20 12 D42A2PA05 / D42L2PA05 208/230-60-1 26 40 8 15.6 20 12 D42A2PB06 / D42L2PB06 208/230-60-3 20 25 10 15.6 20 12 D48A2PA05 / D48L2PA05 208/230-60-1 30 50 8 15.6 20 12 D48A2PB06 / D48L2PB06 208/230-60-3 20 30 10 15.6 20 12 D60A2PA05 / D60L2PA05 208/230-60-1 36 60 6 15.6 20 12 D60A2PB06 / D60L2PB06 208/230-60-3 23 35 8 15.6 20 12 MODEL Field Power Wire Size Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Field Power Wire Size These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes. Outdoor Sound Ratings — Cooling Mode DISTANCE FROM HVAC UNIT dBA 10 Feet 20 Feet 30 Feet 63.5 57.6 56.1 1. Values recorded in Bard Manufacturing Company, Inc. Sound Lab Facility. 2. Actual field results may vary with local conditions that can affect ambient background levels. Cooling Application Data - Outdoor Temperature Model D28A/L D36A/L D42A/L D48A/L D60A/L Return Air (DB/WB) Cooling Capacity Total Cooling 75/62 Sensible Cooling Total Cooling 80/67 Sensible Cooling Total Cooling 85/72 Sensible Cooling Total Cooling 75/62 Sensible Cooling Total Cooling 80/67 Sensible Cooling Total Cooling 85/72 Sensible Cooling Total Cooling 75/62 Sensible Cooling Total Cooling 80/67 Sensible Cooling Total Cooling 85/72 Sensible Cooling Total Cooling 75/62 Sensible Cooling Total Cooling 80/67 Sensible Cooling Total Cooling 85/72 Sensible Cooling Total Cooling 75/62 Sensible Cooling Total Cooling 80/67 Sensible Cooling Total Cooling 85/72 Sensible Cooling 75°F 80°F 85°F 90°F 95°F 100°F 105°F 120°F 125°F 32,600 26,100 34,800 25,300 41,500 25,900 37,500 27,200 40,000 26,400 47,700 27,100 45,900 33,700 49,000 32,700 58,400 33,500 54,400 42,100 58,100 40,800 69,200 41,800 63,000 47,400 67,200 46,000 80,100 47,100 30,300 25,300 33,000 24,800 38,600 25,200 35,800 27,100 39,000 26,500 45,600 26,900 43,200 33,000 47,000 32,300 55,000 32,800 50,500 40,700 55,000 39,900 64,300 40,500 59,200 45,600 64,500 44,700 75,400 45,400 28,400 24,500 31,500 24,200 36,200 24,300 34,300 26,700 38,100 26,400 43,800 26,500 40,700 32,300 45,200 32,000 51,900 32,200 47,000 39,400 52,200 39,000 60,000 39,200 55,800 43,900 62,000 43,500 71,200 43,700 26,600 23,700 30,000 23,700 33,900 23,600 32,800 26,300 37,100 26,300 41,900 26,100 38,300 31,500 43,300 31,500 48,900 31,300 43,800 38,200 49,500 38,200 55,900 38,000 52,700 42,400 59,500 42,400 67,200 42,100 24,900 23,000 28,600 23,200 31,800 22,800 31,400 25,900 36,000 26,100 40,000 25,600 36,200 30,700 41,500 31,000 46,100 30,400 40,900 37,100 47,000 37,400 52,200 36,700 49,600 40,900 57,000 41,300 63,300 40,500 23,500 22,400 27,400 22,800 30,000 22,100 30,100 25,400 35,000 25,800 38,300 25,000 34,200 30,000 39,800 30,500 43,600 29,500 38,400 36,000 44,700 36,600 48,900 35,400 47,000 39,500 54,700 40,200 59,800 38,900 22,300 21,300 20,500 19,700 21,900 21,200 20,800 20,300 26,300 25,400 24,600 23,800 22,400 21,900 21,600 21,200 28,400 27,100 25,900 24,800 21,400 20,600 19,900 19,200 28,700 27,400 26,100 24,900 24,800 24,100 23,400 22,600 33,800 32,600 31,400 30,100 25,400 24,900 24,300 23,600 36,500 34,700 33,000 31,300 24,200 23,400 22,400 21,300 32,300 30,500 28,900 27,300 29,200 28,300 27,400 26,500 38,100 36,400 34,700 33,100 29,900 29,200 28,500 27,700 41,100 38,700 36,500 34,400 28,500 27,400 26,300 25,000 36,100 34,100 32,200 30,600 34,900 34,000 33,000 32,100 42,600 40,600 38,700 37,100 35,800 35,100 34,300 33,600 45,900 43,200 40,700 38,600 34,100 32,900 31,600 30,400 44,400 42,000 39,900 37,900 38,100 36,900 35,700 34,600 52,400 50,100 48,000 45,900 39,100 38,100 37,100 36,200 56,500 53,300 50,400 47,700 37,300 35,700 34,200 32,700 Capacity Multiplier Factors % of Rated Airflow -10 Rated Total BTUH 0.975 1.0 Sensible BTUH 0.950 1.0 19,200 19,900 23,300 20,900 24,000 18,500 23,600 21,700 28,700 22,800 29,500 20,200 25,900 25,500 31,500 26,800 32,400 23,700 29,200 31,400 35,600 33,000 36,600 29,200 36,000 33,500 43,800 35,300 45,100 31,200 Below 65°F (18.3C), unit requires a factory or field installed low ambient control. Return air temperature. 110°F 115°F +10 1.02 1.05 Form No. S3521-516 SupersedesS3521-116 Page 3 of 10 Indoor Blower Performance Free Cooling CFM below 40° Rated Full Load Cooling CFM Electric Heat Airflow 1800 800 1050 1800 1800 800 1100 1800 0.50 1800 950 1250 1800 0.20 0.50 1800 1100 1600 1800 0.20 0.50 1800 1100 1600 1800 MODEL Rated ESP MAX ESP Free Cooling CFM above 40° D28A/D28L 0.15 0.50 D36A/D36L 0.15 0.50 D42A/D42L 0.20 D48A/D48L D60A/D60L Free Cooling Logic Control derives at this decision point, and switches the indoor motor speed. The damper actuator will then adjust to still yield a 55°F supply air temperature. On single-stage models, this only occurs if you have a thermostat/controller with "Y2" cooling stage connected. Factory Built-In Electric Heat Tables KW Amps BTUH Model Voltage Phase 240 208 240 208 240 208 -A05 240/208 1 5.00 3.75 20.8 18.0 17,065 12,799 -B06 240/208 3 6.00 4.50 14.4 12.5 20,478 15,359 LC2000 Dimensions and Weight 3/4" K.O. TYP. 1 1/2" K.O. TYP. The LC2000-200 Controller must be used with the DUAL-TEC™ Series Wall Mount LC Controller Weight: 28 lbs. 16 1/8" 6 1/16" 12" Part Number MIS-3650 Included with LC2000 Description 8301-055 EMI Ferrite Filter (1 needed for each unit connection to Controller) 2 8301-059 TEC-EYE (Service Tool), 5 ft. communication cable 1 8403-079 Remote Temperature and Humidity Sensor with 35' wire 1 8301-058 Remote Temperature Sensor (2 additional sensors may be used) with 35' wire 8301-060 Smoke Detector Optional 8301-061 Hydrogen Detector Optional Addtional Temperature Sensors may be added, but not additional Temperature/Humidity Sensors. Form No. S3521-516 SupersedesS3521-116 Page 4 of 10 Optional DUAL-TEC™ Unit Connectivity with LC2000 Controller DUAL-TEC™ Connectivity Features: The DUAL-TEC™ free cooling unit is made to work in conjunction with the LC2000 Series Controller. Up to two (2) DUAL-TEC™ units can be connected to the LC2000 controller using 2-wire twisted pair with drain. Each unit and the LC2000 controller contains an advanced PLC logic board for communication. The DUAL-TEC™ unit and LC2000 Controller have the following connectivity features: • When used with the LC2000 controller, humidity levels inside the shelter can be monitored and outdoor air intake through the free unit cooling ventilator is closed when humidity levels are unacceptable. • The DUAL TEC unit supply sensor allows temperature monitoring of conditioned and outdoor air entering the structure. By using the supply air temperature measured, the unit is able to supply cooling within the structure without extreme temperature variations. • The DUAL TEC unit outdoor temperature sensor allows free cooling operation when outdoor ambient temperatures permit operation. DUAL-TEC™ Unit #2 (Not required for operation) DUAL-TEC™ Unit #1 LC Controller Climate Controlled Zone Primary Indoor Temperature and Humidity Sensor Hydrogen Detector, Normally Closed Contacts Optional Indoor Temp. Sensor #1 Fire/Smoke Detector, Normally Closed Contacts This illustration demonstrates connection of DUAL-TEC™ units and the LC2000 controller with optional sensors and equipment. Optional Indoor Temp. Sensor #2 Remote Access Computer Form No. S3521-516 SupersedesS3521-116 Page 5 of 10 DUAL-TEC™ Unit in Orphan Mode DUAL-TEC™ Orphan Mode Features: The DUAL-TEC™ free cooling unit is made to function in “orphan mode” if connection to the LC controller is lost due to a severed connection wire or other system failure. When in orphan mode, the DUAL-TEC™ unit will continue to provide cooling to the structure until the connection can be restored. By using a return air temperature sensor measuring structure air temperature and a supply air temperature sensor to measure air provided to the structure, the unit is able to provide cooling. Orphan mode temperature set points are contained inside the DUAL-TEC™ PLC logic board. When connection of the DUAL-TEC™ unit is restored, the unit temperature set points will revert back to the temperature set points programmed into the LC controller. DUAL-TEC™ Unit running in Orphan Mode Supply Temp. Sensor Leaving air Return Temp. Sensor Entering air “UNIT OFFLINE” alarm message LC Controller Signal Lost! Indoor Sensor not used until connection restored. Climate Controlled Zone This illustration demonstrates Orphan Mode unit operation. If connection to the LC controller is lost for any reason, the unit will continue to operate using the return air sensor and supply air temperature sensors in the unit. Form No. S3521-516 SupersedesS3521-116 Page 6 of 10 DUAL-TEC™ Unit in -48VDC Free Cooling Mode DUAL-TEC™ -48VDC only Features: The DUAL-TEC™ free cooling unit is made to function in “-48VDC Free Cooling Mode” if conditions outside the shelter are acceptable for cooling. The DUAL-TEC™ unit will attempt to maintain the set points programmed into the LC controller by bringing outside air into the shelter through the unit ventilator. By running the indoor blower and maintaining a consistent supply temperature by modulating the vent damper blade using -48VDC power supplied, the unit is able to provide cooling. Compressor operation is used to cool the shelter in conjunction with the -48VDC indoor blower and vent if outdoor air intake is inadequate to provide structure cooling. If outdoor ambient conditions reach a point that is unacceptable for cooling the structure, the vent damper blade closes, and the unit runs in “compressor only” cooling mode. DUAL-TEC™ Unit running in -48 Free Cooling Mode Blower Operation Available Leaving air Vent Operation Available Outdoor Air Intake LC Controller Climate Controlled Zone LC Controller Communicates with the DUAL TEC unit. Compressor Cooling Operation Not Used unless LC controller set points are not achievable or outside conditions are unacceptable for vent operation. Indoor Temperature Sensors used. Hydrogen Alarm Operational Fire/Smoke Alarm Operational Ethernet Connection Operational This illustration demonstrates -48VDC unit operation. The DUAL-TEC™ unit is able to bring outdoor air into the structure using the indoor blower and the free cooling ventilator. The LC controller is operational during -48VDC operation along with alarm functionality. Form No. S3521-516 SupersedesS3521-116 Page 7 of 10 TEC-EYE™ DIAGNOSTIC TOOL FOR USE WITH DUAL-TEC™ UNITS TEC-EYE™ Features: TEC-EYETM Connection to DUAL-TEC™ Unit PLC Logic Board The DUAL-TEC™ free cooling unit contains a PLC logic board located inside the unit control panel. The TEC-EYE™ tool, included with the LC2000 controller, allows for diagnostics and unit set point settings to be completed at the unit. This allows the user to complete various tasks outside where the units are located, and access to the inside controller is not needed for many tasks. Using an RJ11 modular phone connection and the cord provided with the TEC-EYE™, the service technician or contractor can run testing procedures or verify unit installation. Magnets on the back of the TEC-EYE™ allow for temporary mounting to the side of the DUAL-TEC™ unit while these tasks are being completed. Modular Phone Connector for TEC-EYETM Hand-Held Diagnostic Tool TEC-EYE™ Diagnostic Tool Part #8301-059 TEC-EYE™ Display UP KEY ALARM KEY MENU KEY ENTER KEY ESCAPE KEY ALARM KEY Allows viewing of active alarms Silences audible alarms Resets active alarms DOWN KEY UP KEY Steps to next screen in the display menu Changes (increases) the value of a modifiable field MENU KEY Allows entry to Main Menu ENTER KEY Accepts current value of a modifiable field Advances cursor ESCAPE KEY Returns to previous menu level Cancels a changed entry DOWN KEY Steps back to previous screen in the display menu Changes (decreases) the value of a modifiable field DUAL-TEC™ UNIT ALARMS Alarm Features: The DUAL-TEC™ free cooling unit is capable of sending and storing various unit alarms and contains the following alarm features: • Low Refrigerant Pressure Alarm • High Refrigerant Pressure Alarm • Landline/Shore/Prime Power Outage • Dirty Air Filter Alarm • DC Free Cooling Damper Fails to Open Alarm • DC Free Cooling Damper Fails to Close Alarm • Communication Failed Alarm • Supply Air Temperature Sensor Failed Alarm • Outdoor Temperature Sensor Failed Alarm • Outdoor Humidity Sensor Failed Alarm • Return Air Temperature Sensor Failed Alarm NOTE: See D-Series and LC2000 Installation Manual for Network, LC Controller and Shelter Alarms. Form No. S3521-516 SupersedesS3521-116 Page 8 of 10 Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal) Model Width Depth Height (W) (D) (H) Supply A B Return C B E F G I J K L M N O P Q R S T D28A/L D36A/L 42.075 22.432 84.875 9.88 29.88 15.88 29.88 43.88 13.56 31.66 30.00 32.68 26.94 34.69 32.43 3.37 43.00 23.88 10.00 1.44 16.00 1.88 D42A/L D48A/L 42.075 22.432 93.000 9.88 29.88 15.88 29.88 43.88 13.56 37.00 30.00 40.81 35.06 42.81 40.56 3.37 43.00 31.00 10.00 1.44 16.00 10.00 D60A/L All dimensions are in inches. Dimensional drawings are not to scale. D**A RIGHT HAND UNIT DT HEATER ACCESS PANEL W BUILT IN RAIN HOOD 4° PITCH 2.13 ELECTRIC HEAT A C. BREAKER/ DISCONNECT ACCESS PANEL (LOCKABLE) VENT HOOD DOOR VENTILIATION AIR F E O Side Wall Mounting Brackets (Built In) D SUPPLY AIR OPENING Top Rain Flashing Shipping Location I 7" Condenser Air Outlet S B S H Optional Electrical Entrances C LOW VOLTAGE ELECTRICAL ENTRANCE K J Cond. Air Inlet HIGH VOLTAGE ELECTRICAL ENTRANCE L S RETURN AIR OPENING VENT HOOD G R M S S P T FRONT VIEW SIDE VIEW DRAIN N Q Units ship fully assembled with Economizer Vent Hood installed. BACK VIEW BOTTOM INSTALLATION BRACKET BUILT IN RAIN HOOD 4° PITCH W D**L LEFT HAND UNIT DT 2.13 D VENT HOOD DOOR H G Condenser Air Outlet BACK VIEW I C. BREAKER/ DISCONNECT ACCESS PANEL (LOCKABLE) Top Rain Flashing Shipping Location 7" Optional Electrical Entrances J K Cond. Air Inlet Outdoor recommended minimum clearances for service and proper airflow: Left Side 20 inches; Right Side 20 inches; Front Clearance to a solid barrier 15 feet Indoor recommended minimum clearances to unit return is 24 inches. Supply must be able to freely distribute conditioned air through the structure for proper unit operation. S S RETURN AIR OPENING S L M HIGH VOLTAGE ELECTRICAL ENTRANCE SIDE VIEW S B VENT HOOD LOW VOLTAGE ELECTRICAL ENTRANCE R SUPPLY AIR OPENING ELECTRIC HEAT C DRAIN E O Side Wall Mounting Brackets (Built In) A VENTILIATION AIR F HEATER ACCESS PANEL S P T N Q BACK VIEW BOTTOM INSTALLATION BRACKET MIS-3618 A Form No. S3521-516 SupersedesS3521-116 Page 9 of 10 Air Conditioning Wall-Mount Model Nomenclature 1-Stage Compressor Models D 36 A 2 P A MODEL SERIES CAPACITY | 28 - 2.3 Ton 36 - 3 Ton 42 - 3½ Ton 48 - 4 Ton 60 - 5 Ton 4 P X X KW 05 - 5KW (1 Phase) 06 - 6KW (3 Phase) REVISIONS COLOR OPTIONS X-Beige 1-White 4 - Buckeye Gray A-Right Hand L - Left Hand PLC CONTROLLER 05 VOLTS & PHASE A-230/208-60-1 B-230/208-60-3 -48VDC Free Cooling Unit X J CONTROL MODULES J = HPS, LPS, CCM, LAC, Alarm Contacts, Start Assist (1-Phase only) C = "J" Module plus Comp. CCH SPECIAL FEATURES FILTER OPTIONS P -2" Pleated (MERV 8) M -2" Pleated (MERV 11) COIL OPTIONS X-Standard 3 - Phenolic Coated Evaporator and Condenser for coastal or other severe duty environments. DUAL-TEC™ Standard Controls High Pressure Switch: Required Safety Device that also provides protection to the compressor system when system refrigerant pressure is above an acceptable level. Auto Reset, 650 psig. Output to compressor control module. Low Pressure Switch: Provides protection to the compressor when refrigerant pressure falls below an acceptable level. Auto Reset, cut out at 40 psig. Output to compressor control module. Low Ambient Control: Modulating control that removes power from the condenser fan to allow for unit compressor cooling operation at outdoor ambient temperatures below 65°F. Factory set for system performance. Screw-on connection for easy servicing. Output to condenser fan motor. Compressor Control Module: Compressor protection device that has a 30-second to 5-minute timer. This module features a delay-on-make for initial startup for a minimum of 2 minutes plus 10% of the timer setting. There is no delay during routine operation. Allows one automatic retry after high pressure switch activation, then goes into hard lockout mode. Output to PLC logic board. Start Assist (Single Phase Models Only): PTCR motor starting device increases compressor motor torque 2-3 times. Supply Air Sensor: 10K Thermistor measures supply air temperature, output to PLC logic board. Return Air Sensor: 10K Thermistor measures return air temperature, output to PLC logic board. Evaporator Coil Sensor: 10K Thermistor prevents coil freezing due to low return air temperature. Output to PLC logic board. Outdoor Temperature & Enthalpy Sensor: 10K Temperature sensor and 4-20mA humidity transmitter, output to PLC logic board (PLC defaults to temperature only). Phase Monitor (3-Phase Models Only): Prevents 3-phase compressor operation to protect the compressor if the device senses incorrect phasing. LED indicator light. Filter Switch: Adjustable switch to indicate the unit air filter needs to be replaced. Output to PLC logic board. DUAL-TEC™ Optional Controls Compressor Crankcase Heater: 2-wire heater that prevents refrigerant migration and mixing with crankcase oil when the unit is off, prevents condensation of refrigerant in the crankcase of the compressor, and keeps refrigerant at a temperature higher than the coldest part of the system. Recommended for Canada and cold climate compressor operation. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Form No. S3521-516 SupersedesS3521-116 Page 10 of 10 Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S3521 May, 2016 Supersedes: S3521-116