2620T/2635T Recording Thermometers Hydra Series II-based precision thermometer system for calibration applications NIST traceable and DKD certified calibration covers the Hydra Series II and probe as a system Hydra Logger Software included 18 additional measuring channels for thermocouple, dc and ac voltage, frequency, and 2-wire Ohms measurement 2635T The Fluke 2635T and 2620T Recording Thermometers are precision multi-channel temperature recording and logging instruments that deliver up to 0.1°C accuracy (3 sigma, one year accuracy specification*) for temperature monitoring and calibration applications. Based on Fluke’s 20 channel Hydra Series Ordering Information 2620T: Recording thermometer with Probe and Hydra Logger Software 2635T: Recording thermometer with Probe, Hydra Logger Software, and 256K PC memory card 2600A-101: EXTRA SPRT probe, 100 Ohm PT, Probe with soft case only 2600A-904: TrendLink Software II data loggers, these units are matched with a precision SPRT probe (RTD) on channel one and calibrated as a system for maximum accuracy and precision. Calibrations are NIST traceable and DKD certified. Each unit is delivered with current calibration data, ready for use. Hydra Logger Software is also included with each unit for support of basic data collection and easy instrument configuration. Optional TrendLink for Fluke trending software is also available for electronic chart recording display an analysis. In addition to being a precision thermometer, both models are capable of measuring up to 18 additional channels of thermocouple, dc and ac volts, frequency, and 2-wire Ohms. A total for 10 RTD probes can be connected and recorded at one time. Summary Specifications* 2620T/2635T Recording Thermometers Temp Probe Uncertainty -196°C 0°C 100°C 200°C 300°C 400°C ± 0.003 ± 0.005 ± 0.005 ± 0.005 ± 0.006 ± 0.006 2635A Uncertainty ITS 90 ± 0.05 ± 0.09 ± 0.10 ± 0.12 ± 0.14 ± 0.16 2635T Uncertainty (rss method) ± 0.05 ± 0.09 ± 0.10 ± 0.12 ± 0.14 ± 0.16 2620A Uncertainty IPTS68 ± 0.13 ± 0.09 ± 0.12 ± 0.18 ± 0.24 ± 0.35 2630T Uncertainty (rss method) ± 0.13 ± 0.09 ± 0.12 ± 0.18 ± 0.24 ± 0.35 * All specifications are based on three standard deviations from nominal value (3 sigma). Actual measured point values are often 10 times better than published specifications. * For detailed specifications, contact your Fluke representative or visit the Fluke web site at www.fluke.com. RECORDING THERMOMETERS Elveveien 28, 3262 Larvik Tlf. 33 16 57 00 - Faks 33 16 57 01 post@instrutek.no - www.instrutek.no