903-131 C ZM PRO SM

advertisement
ZoneMaster PRO SM
200kA to 340kA power surge protection for total
facility protection
O
Outdoor Rated Enclosure NEMA 3R/4
standard
O
Large block MOV & SAD Hybrid protection
technology
O
Thermal and short circuit protection plus
fused disconnect as standard
O
Surge counter and power filter
O
Integrated fused disconnect
O
Patented technology
The ZoneMaster PRO SM Series of products is
designed for the optimum control of surges.
Using combinations of SAD and Large Block
MOV modules, the unit provides exceptional
protection
performance
for
sensitive
equipment. The ZoneMaster PRO SM provides
multiple levels of redundancy with the SAD
primary stage, backed by high current capacity
of the MOV stage.
The ZoneMaster PRO SM Series has the
option of line to neutral protection only. This
option is required by radio manufacturers who
specify that there will be no neutral to ground
connections or components after the shelter
(or building) neutral-ground bond point.
In addtion, multiple SAD modules are available
for critical sites. The ZoneMaster PRO 200
SSM model comes with two (SS) SAD modules
for extremely critical sites providing the lowest
let-through voltage possible.
Each module has a patented dual fusing design
that provides both thermal and overcurrent
protection at the module level. Dual circuits in
each module ensures redundancy and
continued protection in the event of a surge
that exceeds the module’s capacity.
The integrated fused disconnect is a standard
item in all ZoneMaster PRO products. This
provides an extra safety feature for the
servicing of the unit and complies with NEC
requirements, thereby elevating the kAIC
rating of the unit.
remote installation and includes a test switch
function and a switch to silence the audible
alarm.
An standard power filter is available which
eliminates a broad range of load or line
generated high frequency noise. This UL 1283
Listed filter module has a noise attenuation of
75dB at 100KHz-100MHz and will attenuate
6kV transients down to a mere 200V without
the support of other surge components.
ZoneMaster PRO units are tested as per
ANSI/IEEE C62.41 and C62.45.
The multi-mode surge counter actually counts
the number of times a surge current is
discharged when a transient is suppressed;
many competitive products count only voltage
impulses. These counters show the number of
transient
voltages
exceeding
the
manufacturer’s set limits and can even be used
to identify which phase has received the most
surges - an industry first.
Remote monitoring is facilitated by the optional
audio/visual alarm annunciator panel which
offers clear indication of the status of
the ZoneMaster PRO unit and a
flexibility not offered by built-in
products. This panel can
be mounted either
adjacent to the
ZoneMaster
PRO or in a
AC Power
Protection
Specification
All figures typical at 77°F (25°C) unless otherwise stated
Maximum continuous operating voltage
25% above nominal
Surge current capacity
SM versions
12kA SAD/200kA MOV
SMM versions 12kA SAD/340kA MOV
SSM versions 24kA SAD/200kA MOV
Ambient temperature limits
–40°F to +185°F (–40°C to +85°C) - working
Humidity
95% RH (non-condensing)
Enclosure
NEMA 1 (standard)
Terminals
2 AWG (32mm2)
Mounting
Surface mount by 0.31” (8mm) diameter holes
or optional flush mount available
Indication
MOV modules:
Continuous visual status monitoring
Green LED Lit = Full protection
Red LED Lit = Reduced (Standby) OR no
protection
SAD modules:
Green LED on
Protection present
Green LED off
Module failure
Remote contacts
NO/NC 125Vac, 2A rated
Weight
25.4 lbs approx.
Dimensions
Enclosure: See figure 1
Modules: 1.25” x 5.3” x 2.5”
(32mm x 135mm x 64mm)
ZoneMaster PLUS
Model
Maximum
surge current
(Im
max) (kA)
Working
voltage
(V)
Let-through voltage
@3kA
@10kA (In
n)
(V)
(V)
Phase types
PLUS 340 SMMN
19400XC1
19401XC1
19402XC1
340
340
340
120/240 split
120/208
120/240
310
310
310
356
356
356
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire Delta
PLUS 200 SMN
19200XC1
19201XC1
19202XC1
200
200
200
120/240 split
120/208
120/240
312
312
312
356
356
356
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire Delta
PLUS 200 SSMN
19600XC1
200
120/240 split
310
356
Split phase 3 wire
PLUS 200 /SSM
(L-N protection only)
19800XC1
19801XC1
19802XC1
200
200
200
120/240 split
120/208
120/240
290
290
290
356
356
356
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire Delta
Tested as per ANSI/IEEE C62.41 and ANSI/IEEE C62.45, Uoc=6kV
KEY: SAD/MOV models
S = SAD (Silicone Avalanche Diode), M = (Metal Oxide Varistor), N = Neutral module
e.g. Models with (SSM) have 2 SADs per phase and 1 MOV per phase. Models with (SMN) have 1 SAD per phase, 1
MOV per phase and 1 Neutral module. Models with (SMMN) has 1 SAD per phase, 2 MOVs per phase and 1 Neutral
module.
Power filter standard
Maximum continuous operating voltage
400Vac rated (L-N)
Let-through voltage
200V (@ 3kA 8/20µs)
Maximum attenuation (typical)
75dB maximum (100kHZ to 100MHz)
Remote monitoring unit option
Indication
Green LED on Protection present
Red LED on
Fault indication
Audible alarm Fault indication
Connectors
Screw terminal
Terminals
14 AWG (2mm2)
Surge counter standard
LCD display
Counts 0 to 99,000
Data storage
40 years without power
Count threshold
100A or 250A settings surge current
Modes of measurement
Counts surges in normal mode (L-N all
phases) or common mode (L-G, N-G)
Figure 1 Dimensions
Note: In accordance with our policy of continuous
improvement, we reserve the right to change the product’s
specification without notice.
Cooper Crouse-Hinds MTL Inc. (formerly Atlantic Scientific Corporation)
4300 Fortune Place, Suite A ³ W. Melbourne, FL 32904 USA
Tel: +1 800-544-4737, +1 321-725-8000 Fax: +1 321-727-0736
E-mail: sales@atlanticscientific.com, WWW: www.atlanticscientific.com
All figures typical at 77°F (25°C) unless otherwise stated
903-131 Rev C ZM Pro SM 13/APR/11
To order specify Model number as per specification table above
Add suffix A for remote monitoring unit