CONFIGURABLE SAFETY RELAYS MSI-i/R, MSI-ix/Rx The cycle control function of the configurable MSI Safety Relays allows efficient semi-automatic processes Special features z Single or double-cycle operation with 30 s / 30 min time monitoring z Light Curtain cycle control and constant rear area monitoring (MSI-ix/Rx) z Additional E-STOP control device or Safety Switch can be connected z z z z z z (MSI-ix/Rx) Relay switching cycle counting for preventive maintenance (MSI-ix/Rx) Potential-free safety-related switching outputs Contact load rating, 5 A Plug-in connection terminals and output modules Interface for PC-supported diagnostics and easy start-up Housing width, 35 mm With manual feeding-in at a machine it saves time if the safety sensor system gives a start command to the machine directly after the work piece has been fed in, i.e. without additional button actuation. This semi-automatic process, which is frequently required with the use of presses, can be enabled with the cycle control function of the configurable MSI-I Safety Relay. The device, type 4 in accordance with IEC/ EN 61496-1, acts as the link between the opto-electronic protective devices and the machine control system; it enables an efficient production with higher ergonomics – both in the single-cycle process (one protective field penetration/release) and in the double-cycle process. The connection of an additional type 4 or type 2 protective device for the rear area monitoring is also possible. Compared with the MSI-i, the extended MSI-ix/Rx variant enables the connection of up to four opto-electronic protective devices and an E-STOP control device or a Safety Switch. Typical areas of application z Interface module for Light Curtain cycle control z Mechanical and hydraulic presses z Cycle control and rear area monitoring on press brakes TNT 35 p. 478 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net Safety Switches MSI-i/R, MSI-ix/Rx Type 4 Safety Command Devices On request On request Up to 4 (depending on the category of the upstream protective device) Safety Relays 0 24 V DC, ±20 % 22 to 64 ms depending on safety sensor MSI-i/R: 2 relay outputs (NO) MSI-ix/Rx: 3 relay outputs (2 NO, 1 NC) Relay output (NO) Features Functions MSI-ix/Rx 2 4 1 2 z z z z z z z z z z z z z z BG geprüft Further information z Ordering information z Electrical connection z Technical data z Dimensional drawings z Accessories ordering information Page 460 460 461 463 Glossary Max. number of type 2 AOPDs or E-STOP control devices (category 2) Max. number of type 4 AOPDs or E-STOP control devices (category 4) Start/restart interlock (RES), optionally with/without Static contactor monitoring (EDM) Dynamic contactor monitoring (EDM) Cross circuit monitoring PC diagnostics interface Cycle control (single and double cycle) 30 s time monitoring for cycle operation Relay switching cycle counter for preventive maintenance System error signal output Secondary switching device (SSD) – output MSI-i/R Accessories Configurable Safety Relays 0...+55°C -25...+70°C 35 mm x 99 mm x 113.6 mm 456 Product Finder Type in accordance with IEC/EN 61496-1 (Annex A) SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 Performance Level (PL) in accordance with EN ISO 13849-1 Category in accordance with EN ISO 13849 Stop category in accordance with IEC/EN 60204-1 Supply voltage Response time Safety-related switching outputs (OSSDs) Secondary switching device (SSD), only MSI-ix/Rx Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D) Safety Locking Devices Important technical data, overview z z z www.leuze.com/interfaces/ 459 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net CONFIGURABLE SAFETY RELAYS Ordering information MSI-i/R, MSI-ix/Rx Included in delivery: Connecting and operating instructions Functions: Cycle control, start/restart interlock, contactor monitoring, PC diagnostics interface MSI-i/R, MSI-ix/Rx Art. no. Article Description Safety-related switching outputs (OSSDs) 549902 MSI-i/R Configurable MSI Safety Relay, cycle control 2 relay outputs 549903 MSI-ix/Rx Configurable MSI Safety Relay, cycle control, extended functions 3 relay outputs Electrical connection, MSI-i/R connection example + 24V + 24V 2 3 4 1 2 3 1 -K4 2 1 L+ -W1 1 4 -W2 1 2 3 4 5 L- 6 1 -K3 2 7 8 Test S2 20 AOPDs MSI-i / R Diagn. State 9 21 13 19 14 11 2 10 1 EDM S1 23 Reset T2 22 FE (via DIN rail) T1 24 Select 15 Clear + 24V 4 S1-S2 0V 5 -A3 RS232 SOLID-4E / SD4R-E 6 0V 5 OSSD1 4 OSSD2 3 EDM 2 RES active 1 FE 0V SOLID-4E / SD4T 3 -A2 FE 4 Start Restart +24V 2 n.c. +24V 1 Test -A1 R - Output State 7 6 Var. B -W1 3 SH -W2 7 S -K3 A1 -K4 Var. A A1 A2 1 A2 2 -K3 -K4 -K3 -K4 L- 0V PE L+ 0V PE Configurable MSI-i/R Safety Relay with SOLID-4 Safety Light Curtain Please observe the operating instructions of the components! 460 We reserve the right to make changes • 15-02_MSI-I_IX.fm © 2010 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net Safety Switches MSI-i/R, MSI-ix/Rx nop = 4,800 nop = 28,800 On request On request nop = 86,400 On request With DC1 (ohmic load) With AC1 (ohmic load) Number of cycles until 10 % of the components have With DC13 (inductive load) On request a failure to danger (B10d) With AC15 (inductive load) Low load (20% nominal load) Category in accordance with EN ISO 13849 Up to 4 (depending on the category of the upstream protective device) Stop category in accordance with IEC/EN 60204-1 0 Supply voltage 24 V DC, ±20 % Restart delay time Safety class Protection rating Ambient temperature, operation Ambient temperature, storage Relative humidity Dimensions (W x H x D) Mounting Connection system Current consumption Safety-related switching outputs (OSSDs) Secondary switching device (SSD), only MSI-ix/Rx Switching voltage, switching current (for OSSDs) Test outputs T1 and T2 100 ms II IP 20 0...+55°C -25...+70°C Max. 93 % 35 mm x 99 mm x 113.6 mm on 35 mm DIN rail Plug-in, encoded screw terminals up to 2.5 mm2 Approx. 200 mA without external load MSI-i/R: 2 relay outputs (NO) MSI-ix/Rx: 3 relay outputs (2 NO, 1 NC) Relay output (NO) 60 V DC, 250 V AC, 5 A maximum, 20 mA minimum Glossary Response time 22 ms with connection of type 4 AOPD with transistor output 64 ms with connection of type 4 AOPD with relay output 64 ms with connection of type 2 AOPD 64 ms with connection of Safety Switches (electro-mechanical) Safety Command Devices On request Safety Relays On request Configurable Safety Relays On request Accessories Type 4 Product Finder General system data Type in accordance with IEC/EN 61496-1 (Annex A) SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 Performance Level (PL) in accordance with EN ISO 13849-1 Service life (TM ) in accordance with EN ISO 13849-1 Probability of a failure to danger per hour (PFHd) in accordance with the average number of annual nop activations (for the calculation formula, see EN ISO 13849-1:2008, chapter C.4.2 and C.4.3) Safety Locking Devices Technical data Test interval, 200 ms Test pulse width delayed, 24 ms each Response time, type 2 AOPD on test request, 2...18 ms Selecting cycle modes Operating mode key switch or jumper for constant operating mode Cycle deletion NC contact for 24 V DC in machine cycle With connection of type 4 AOPD with relay output, min. 60 ms break time With connection of type 2 AOPD, min. 60 ms break time www.leuze.com/interfaces/ We reserve the right to make changes • 15-02_MSI-I_IX.fm © 2010 Leuze electronic GmbH + Co. KG 461 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net CONFIGURABLE SAFETY RELAYS Technical data Control inputs Start/restart interlock (RES) Contactor monitoring (EDM) Signal outputs OSSD status AOPDs status Start/restart function status (RES) Additional signal outputs MSI-ix/Rx MSI error Pre-selected switching cycles reached Connectable safety sensors Safety sensors (AOPDs) Safety Switch/E-STOP control device Potential-free NO contact (button or key switch) Feedback of positive-guided contacts of sequential contactors pnp transistor output pnp transistor output pnp transistor output Push-pull transistor output Push-pull transistor output MSI-i/R: 1 Type or type 3 AOPD or up to 2 type 2 AOPDs MSI-ix/Rx: Up to 2 type 4 or type 3AOPDs or up to 4 type 2 AOPDs MSI-i/R: Up to 2 Safety Switches in accordance with EN 1088 and E-STOP command device in accordance with EN ISO 13850 MSI-ix/Rx: Up to 4 Safety Switches in accordance with EN 1088 and E-STOP command device in accordance with EN ISO 13850 Please note the additional information in the connecting and operating instructions and at www.leuze.com/interfaces. 462 We reserve the right to make changes • 15-02_MSI-I_IX.fm © 2010 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net Safety Switches MSI-i/R, MSI-ix/Rx Safety Locking Devices Dimensional drawings Configurable MSI-i/R and MSI-ix/Rx Safety Relays 13 16 1 4 2 5 3 6 13 16 Warn. Diagn. State S3 & S4 State S1 & S2 Locked Locked Fault MSI Rx Output 7 10 14 15 17 18 8 11 Diagn. Fault Fault 19 22 20 21 23 24 7 10 8 11 35 S1 & S2 MSI ROutput MSI- ix 9 12 14 15 17 18 Safety Relays 3 6 Fault MSI- i 9 12 19 22 20 21 23 24 35 Configurable Safety Relays 2 5 99.0 1 4 Safety Command Devices 111 113.6 Dimensions in mm Accessories Our 3D CAD models can be found under: www.leuze.com/3d-cad-models. Accessories ordering information Product Finder Glossary See page 456. www.leuze.com/interfaces/ We reserve the right to make changes • 15-02_MSI-I_IX.fm © 2010 Leuze electronic GmbH + Co. KG 463 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net