RC-7608
Module Lengths
T5/T5HO lamp versions
Row Configurations
Verge wall systems are available in nominal 4ft
and 8ft modules. Exact overall module lengths are
shown to the right (without endcaps).
4ft
The tables below indicates how nominal 4ft and 8ft modules can be combined to create continuous rows
of various lengths. Modules can be combined in any order.
3' 10-1/2"
8ft
7' 9"
Note:T5/T5HO and T8 lamp versions are different lengths. See Table A for T5/T5HO versions and Table B for T8
lamp versions.
Table A: T5/T5HO lamp versions
Indicates overall nominal length of module.
Module lengths do not include endcaps.
Endcap dimensions are shown below.
T8 lamp versions
Nominal
Row Length
4ft
4' 0"
4'
8ft
4'
8'-1/2"
20'
Overall row lengths do not include endcaps.
Add two endcaps to the overall length
of each row.
8'
1x
1x
11' 7-1/2"
12'
2x
15' 6"
16'
1x
2x
19' 4-1/2"
20'
3x
23' 3"
24'
1x
3x
27' 1-1/2"
28'
4x
31' 0"
32'
4x
34' 10-1/2"
36'
5x
38' 9"
40'
1x
44'
• Variable wall mount brackets can be positioned
within 2”-4” of fixture end or joint.
1x
5x
42' 7-1/2"
44'
6x
46' 6"
48'
6x
50' 4-1/2"
52'
7x
54' 3"
56'
1x
7x
58' 1-1/2"
60'
8x
62' 0"
64'
1x
8x
65' 10-1/2"
68'
9x
69' 9"
72'
9x
73' 7-1/2"
76'
10x
77' 6"
80'
10x
81' 4-1/2"
84'
11x
85' 3"
88'
48'
52'
• Maximum distance between mounts is 48”
1x
56'
60'
64'
68'
72'
76'
1x
80'
84'
88'
!
1x
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2013 Philips Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
ledalite.com
Number
of Modules
Required
4'
4'
40'
Mount Spacing
endcaps)
3' 10-1/2"
32'
36'
Nominal
Row Length
7' 9"
24'
28'
Installed Row
Length
( not including
1x
16'
2-3/16"
8'
1x
8'
12'
Endcaps
Number
of Modules
Required
Table B: T8 lamp versions
8'
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
Installed Row
Length
( not including
endcaps)
4' 0"
1x
8'-1/2"
1x
12'-1/2"
2x
16' 1"
2x
20' 1"
3x
24' 1-1/2"
3x
28' 1-1/2"
4x
32' 2"
4x
36' 2"
5x
40' 2-1/2"
5x
44' 2-1/2"
6x
48' 3"
6x
52' 3"
7x
56' 3-1/2"
7x
60' 3-1/2"
8x
64' 4"
8x
68' 4"
9x
72' 4-1/2"
9x
76' 4-1/2"
10x
80' 5"
10x
84' 5"
11x
88' 5-1/2"
Page 1
RC_Wall_76.pdf
0313
Verge
Wall
Row Configurations
RC-7608
Power Feed
Emergency Circuit (EM), Night Light (NL) and Battery Pack (BP) placement in rows
Power for the entire row can be placed at either end or any joint. See examples below.
Placement of EM/NL/BP modules is variable throughout a row. See examples below of EM/NL/BP installed in 20ft rows.
= Power mount
Example A
4'
8'
EM/NL/BP
= Non-power mount
Example A
4'
8'
IMPORTANT: Whenever longer
rows are made up of both 4' and
8' modules, EM/NL/BP sections
will always be installed in 8'
modules. If specific site restrictions
require EM/NL/BP sections to
be installed in 4' sections, please
contact the factory.
8'
-ORExample B
4'
8'
NOTE: Each row will be supplied standard
with a power mount and a 4 conductor
power cord*.
18/4 conductor AWM power
cord:
Example C
4'
8'
EM/NL/BP
Example B
8'
8'
EM/NL/BP
Example C
8'
8'
Max. 10 amps
Max. 600V
Good for 2 circuit feeds or
a 1 circuit feed with a NL/BP
hot lead.
4'
-OR-
4'
Power feeds for rows installed with Night Light (NL) or Battery Pack (BP)
Every NL/BP module will be supplied with an additional 4 conductor power cord and power mount to enable variable
power locations, as shown in the examples below.
For NL and BP installation, power can be installed adjacent to normal power or in a separate location.
Emergency Circuit (EM), Night Light (NL) or Battery Pack (BP)
Option
Modules are available with optional EM/NL circuit or BP. EM/NL/BP each power one 4ft end
section of a module. EM/NL/BP sections will always be installed on the right side (when facing wall).
See examples A and B below.
Example A 2 power drops
8'
8'
8'
= Power mount, normal
-ORExample B 1 power drop
4ft module
NL/BP
4'
= Power mount, NL/BP
NL/BP
4'
8'
8'
= Non-power mount
8'
EM/NL/BP
Power feeds for rows installed with Emergency Circuit (EM)
Every EM module will be supplied with an additional 4 conductor power cord and power mount to enable
variable power locations, as shown in the example below.
8ft module
For EM installation, in all instances, code restrictions require two separate power drops, one for normal power and
one for EM power. EM power must be installed adjacent to the EM module. See example A below.
EM/NL/BP
Example A 2 power drops
= Power mount, normal
EM
4'
8'
8'
Thru-wiring for EM circuit is not permitted.
!
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2013 Philips Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
ledalite.com
8'
= Power mount, EM
= Non-power mount
Page 2
RC_Wall_76.pdf
0313
Download