Verge Row Configurations Suspended Module Lengths Verge suspended systems are available in nominal 4ft and 8ft modules. Exact overall module lengths are shown to the right (without endcaps). RC-7606 Row Configurations 4ft 4'-3/16" Indicates overall nominal length of module. Module lengths do not include endcaps. Endcap dimensions are shown below. 8ft The table below indicates how nominal 4ft and 8ft modules can be combined to create continuous rows of various lengths. Modules can be combined in any order. 8'-3/8" Nominal Row Length Endcaps Number of Modules Required 4' 2-3/16" 4' Overall row lengths do not include endcaps. Add two endcaps to the overall length of each row. 1x 8' 12' 1x 16' 20' Mount Spacing 24' For on-grid T-bar ceiling installations, mounts attach directly to Tee. For non-accessible ceilings and off-grid T-bar installations, the graphic below indicates mount spacing for typical row lengths. Mounting options are also available for a wide variety of other ceiling types. See Suspended Mounting Options document for more detailed information. 28' 1x 1x 32' 36' 1x 40' 44' 3' 11" 4ft 8ft 7' 11-3/16" 12ft Indicates mounting location 7' 11-3/16" 20ft 24ft 28ft 32ft 52' 1x 56' 4'-3/16" 60' 8'-3/8" 7' 11-3/16" 16ft 1x 48' 7' 11-3/16" 4'-3/16" 1x 64' 68' 8'-3/8" 7' 11-3/16" 8'-3/8" 8'-3/8" 7' 11-3/16" 8'-3/8" 8'-3/8" 7' 11-3/16" 8'-3/8" 8'-3/8" 1x 72' 76' 1x 80' 4'-3/16" 8'-3/8" 84' 1x 88' 92' 1x 96' 100' ! ATTENTION: Install in accordance with national and local building and electrical codes. © 2013 Philips Ledalite Phone: 604.888.6811 Fax: 800.665.5332 ledalite.com 8' 1x Installed Row Length ( not including endcaps) 4'-3/16" 1x 8'-3/8" 1x 12'-9/16" 2x 16'-3/4" 2x 20'-15/16" 3x 24' 1-1/8" 3x 28' 1-5/16" 4x 32' 1-1/2" 4x 36' 1-11/16" 5x 40' 1-7/8" 5x 44' 2-1/16" 6x 48' 2-1/4" 6x 52' 2-7/16" 7x 56' 2-5/8" 7x 60' 2-13/16" 8x 64' 3" 8x 68' 3-3/16" 9x 72' 3-3/8" 9x 76' 3-9/16" 10x 80' 3-3/4" 10x 84' 3-15/16" 11x 88' 4-1/8" 11x 92' 4-5/16" 12x 96' 4-1/2" 12x 100' 4-11/16" Page 1 RC_Suspended_76.pdf 0313 Verge Suspended Row Configurations RC-7606 Power Feed Emergency Circuit (EM), Night Light (NL) and Battery Pack (BP) placement in rows Power for the entire row can be placed at either end or any joint. See examples below. Placement of EM/NL/BP modules is variable throughout a row. See examples below of EM/NL/BP installed in 20ft rows. = Power mount Example A 4' 8' EM/NL/BP = Non-power mount Example A 4' 8' IMPORTANT: Whenever longer rows are made up of both 4' and 8' modules, EM/NL/BP sections will always be installed in 8' modules. If specific site restrictions require EM/NL/BP sections to be installed in 4' sections, please contact the factory. 8' -ORExample B 4' 8' NOTE: Each row will be supplied standard with a power mount and a 4 conductor power cord*. 18/4 conductor AWM power cord: Example C 8' Max. 600V Good for 2 circuit feeds or a 1 circuit feed with a NL/BP hot lead. Emergency Circuit (EM), Night Light (NL) or Battery Pack (BP) Option Modules are available with optional EM/NL circuit or BP. EM/NL/BP each power one 4ft end section of a module. To vary placement in a row, modules installed with EM/NL/BP can be reversed 180º as shown below in the 4ft and 8ft modules. 8' EM/NL/BP Example C 8' 8' 4' Power feeds for rows installed with Night Light (NL) or Battery Pack (BP) Every NL/BP module will be supplied with an additional 4 conductor power cord and power mount to enable variable power locations, as shown in the examples below. For NL and BP installation, power can be installed adjacent to normal power or in a separate location. See examples A and B below. Example A 2 power drops NL/BP 4' 8' 8' 8' = Power mount, normal -ORExample B 1 power drop 4ft module 4' -OR- Max. 10 amps 4' 8' EM/NL/BP Example B = Power mount, NL/BP NL/BP 4' 8' 8' = Non-power mount 8' EM/NL/BP Power feeds for rows installed with Emergency Circuit (EM) Every EM module will be supplied with an additional 4 conductor power cord and power mount to enable variable power locations, as shown in the example below. 8ft module -OREM/NL/BP EM/NL/BP For EM installation, in all instances, code restrictions require two separate power drops, one for normal power and one for EM power. EM power must be installed adjacent to the EM module. See example A below. Example A 2 power drops = Power mount, normal EM 4' 8' 8' Thru-wiring for EM circuit is not permitted. ! ATTENTION: Install in accordance with national and local building and electrical codes. © 2013 Philips Ledalite Phone: 604.888.6811 Fax: 800.665.5332 ledalite.com 8' = Power mount, EM = Non-power mount Page 2 RC_Suspended_76.pdf 0313