SERIES M - Auxiliary minicontactors Auxiliary minicontactors (Ith = 16A) Control circuit : alternating current – Control circuit: Alternating current up to 600V Direct current up to 250V – Terminal numbering in accordance with EN 50011 – Fixing system for rapid and simple mounting by claming onto standard 35mm DIN rail (EN 50022) – Screw and push-on terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 – Printed circuit version – Facility to mount instant or timed auxiliary contact blocks and voltage suppressor blocks – Degree of protection IP20 in accordance with IEC 144 – Conform to IEC 947 Number of Utilisation category contacts AC15 Terminal type Contacts acc. to EN 50011 Pack Weight MCRA040AT ◆ MCRA031AT ◆ MCRA022AT ◆ MCRA013AT ◆ MCRA004AT ◆ MCRA040AF ◆ MCRA031AF ◆ MCRA022AF ◆ MCRA013AF ◆ MCRA004AF ◆ MCRA040AI ◆ MCRA031AI ◆ MCRA022AI ◆ MCRA013AI ◆ MCRA004AI ◆ 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 0.170 0.170 0.170 0.170 0.170 0.165 0.165 0.165 0.165 0.165 0.163 0.163 0.163 0.163 0.163 MB0A ◆ 10 0.030 MCRC040AT ◆ MCRC031AT ◆ MCRC022AT ◆ MCRC040AF ◆ MCRC031AF ◆ MCRC022AF ◆ MCRC040AI ◆ MCRC031AI ◆ MCRC022AI ◆ 10 10 10 10 10 10 10 10 10 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 MB0C ◆ 10 0.080 DC13 •3 V 110 220/240 380/400 415 440 500 660/690 4 Cat. no. (3) A 6 6 4 4 3 2.5 1.5 V 24 48 110 220 A 5 3.5 1.2 0.6 •4 Screw 40E 31E 22E 13E 04E 40E 31E 22E 13E 04E 40E 31E 22E 13E 04E Faston 2x2.8 isulated (1) (2) Printed circuit MCRA022ATN •1 •2 4 3 2 1 0 4 3 2 1 0 4 3 2 1 0 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 Spare coil (3) Control circuit: direct current (for DC-interface minicontactors, see J.5) 4 110 220/240 380/400 415 440 500 660/690 MCRA031AFN 6 6 4 4 3 2.5 1.5 24 48 110 220 5 3.5 1.2 0.6 Screw 40E 31E 22E 40E 31E 22E 40E 31E 22E Faston 2x2.8 insulated (1)(2) Printed circuit 4 3 2 4 3 2 4 3 2 0 1 2 0 1 2 0 1 2 Spare coil (3) Available coil voltages MCRA022AID Alternating current (V) ◆ A B C 50Hz 60Hz D E 24 6 12 24 F G H 42 48 J K M 110 115 127 32 48 60 110 120 N S T 220 260 240 208 240 220 277 U W Y 380 415 500 400 440 380 440 480 600 Alternating current (V) Bifrequency coil (4) MCRC031ATD ◆ 1 50/60Hz 24 42 110-115 120 220 230 240 440 2 3 4 5 6 7 8 Direct current (V) ◆ A B DC 6 12 32 24 36 42 48 60 72 110 120 125 220 240 250 C D E F G H I J K L N R S (1) Terminal with wire 1.5 mm2: Ie = 16A with wire 1 mm2: Ie = 10A Insulated terminal type B2.8x0.8 with wire 1 mm2: Ie = 8A to DIN 46247 (2) Faston terminal 1 x 6.3 on request (replace the letter F by H in the catalogue number) (3) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit (4) Voltage operating limits of dual-frequency coils for uninterrupted duty (ED = 100%), temperature = 40°C max. at 60 Hz: 0.85 to 1.1 x Us at 50 Hz: 0.80 to 1.1 x Us Technical specifications, see J.12 Dimensions, see J.20 SERIES M - Auxiliary minicontactors Auxiliary minicontactors interfaces (Ith = 16A) Control circuit: direct current 24V/1.2W (1) – Terminal numbering in accordance with EN 50011 – Fixing system for rapid and simple mounting by claming onto standard 35mm DIN rail (EN 50022) – Screw terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 – Facility to mount timer block and voltage suppressor block – Possibility to add two auxiliary contacts, in 2W version, either frontal or lateral blocks (2) – Degree of protection IP20 in accordance with IEC 144 Number of Utilisation contacts category Control voltage: 24V. Operating limits from 19 to 30V (0.8 to 1.25 x Us) AC15 4 V 110 220/240 380/400 415 440 500 Terminal type Contacts acc. to EN 50011 Pack Weight DC13 A 6 6 4 4 3 2.5 V 24 48 110 220 A 5 3.5 1.2 0.6 Screw •3 •1 •4 •2 40E 4 0 MCRI040ATD 10 0.225 31E 3 1 MCRI031ATD 10 0.225 22E 2 2 MCRI022ATD 10 0.225 MB0ID 10 0.030 Spare coil MCRI040ATD Cat. no. Control circuit: direct current 24V/2W (2) Control voltage: 24V. Operating voltage limits from 17 to 30V (0.7 to 1.25 x Us) 4 Spare coil 110 220/240 380/400 415 440 500 6 6 4 4 3 2.5 24 48 110 220 5 3.5 1.2 0.6 Screw 40E 4 0 MCRK040ATD 10 0.225 31E 3 1 MCRK031ATD 10 0.225 22E 2 2 MCRK022ATD 10 0.225 MB0KD 10 0.030 (1) No possibility of adding instantaneous auxiliary contact blocks. (2) Facility to mount an instantaneous auxiliary contact block of two contacts (MARN2...) or two instantaneous auxiliary contact blocks of one contact (MARL1...). Technical specifications, see J.12 Dimensions, see J.20 SERIES M - Auxiliary minicontactors Instantaneous auxiliary contacts blocks (Ith = 10A) – Terminal numbering in accordance with EN 50005 and EN 50011 – Screw and push-on terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 – Degree of protection IP20 in accordance with IEC 144 – Combinations of front/side mounted auxiliary contact blocks: see pages J.18 and J.19 Front mounting Terminal Number of Combination with type contacts MCRA040AT◆ (40E) (1) according to EN 50011 Screw MARN220AT Faston 2x2.8 insulated (2) MARN440AT 2 2 2 4 4 4 4 4 4 4 4 4 4 •4 •2 2 1 0 4 3 2 1 0 4 3 2 1 0 0 1 2 0 1 2 3 4 0 1 2 3 4 MARN220AT MARN211AT MARN202AT MARN440AT MARN431AT MARN422AT MARN413AT MARN404AT MARF440AF MARF431AF MARF422AF MARF413AF MARF404AF 10 10 10 10 10 10 10 10 10 10 10 10 10 0.025 0.025 0.025 0.040 0.040 0.040 0.040 0.040 0.035 0.035 0.035 0.035 0.035 50E – 50E – 50E – 10 01 10 01 10 01 1 0 1 0 1 0 0 1 0 1 0 1 MARL110AT MARL101AT MARL110AF MARL101AF MARL110AI MARL101AI 10 10 10 10 10 10 0.013 0.013 0.009 0.009 0.008 0.008 – One or two additional blocks, when 9 or 10 contacts are required (combination possible with the front mounting block) – One or two additional blocks on both sides, to cover up to 8 contacts (combination only possible with lateral blocks) Screw 1 1 Faston insul. 1 1 2x2.8 (2) Printed 1 circuit 1 MARL110AI •1 Pack Weight One or two blocks to cover combinations of 5 or 6 contacts without increasing the height of the basic unit. 1 1 Faston insul. 1 1 2x2.8 (2) Printed 1 circuit 1 MARL110AF 20 11 02 40 31 22 13 04 40 31 22 13 04 •3 Cat. no. Lateral mounting Screw MARL110AT 60E 51E 42E 80E 71E 62E 53E 44E 80E 71E 62E 53E 44E Contacts according to EN 50005 (black marking) 10 01 10 01 10 01 (1) Combinations in accordance with IT 553 on request. (2) Terminal with wire 1 mm2: Ie = 10A Insulated terminal type B 2.8x0.8 with wire 1 mm2: Ie = 8A 1 0 1 0 1 0 0 1 0 1 0 1 MARL110ATS MARL101ATS MARL110AFS MARL101AFS MARL110AIS MARL101AIS 10 10 10 10 10 10 0.013 0.013 0.009 0.009 0.008 0.008 SERIES M - Auxiliary minicontactors Accessories MREBC10AC2 Electronic timer block Lateral or frontal fixing on the contactor Time Function 0.5 - 60 sec. Delay ON 0.2 - 24 sec. Delay ON MVB0R Cat. no. Pack Weight For use with Ue MRC..MC0..MC1 MRC..MC0..MC1 24 to 250V AC/DC MREBC10AC2 10 0.040 24 to 250V AC/DC MREBC20AC2 10 0.040 Timer fitment For fixing onto 35mm DIN-rail (EN 50022) For use with MREBC10AC2, MREBC20AC2 MP0AAE2 Cat. no. MVB0R Pack Weight 10 0.005 Cat. no. Pack Weight Voltage suppressor block Connection and (plug-in) fixing onto front of the contactor MMH0 Type Control For use with Ue R/C AC Diode DC MCRA..., MC0A..., MC1A... 12 to 60V 50/60 Hz MP0AAE1 110 to 240V 50/60 Hz MP0AAE2 MP0CAE3 MCRC..., MC0C..., MC1C... 6 to 250V DC 10 0.010 10 0.010 10 0.010 Mechanical interlock Kit comprising mechanical interlock and contactor jointing parts For use with Cat. no. Pack Weight MCR..., MC0..., MC1... MMH0 10 0.002 Cat. no. EAT260 SPR Pack Weight 1 0.050 1 0.001 Identification Sheets of labels (10 sheets of 260 labels each) Labeling plate base Plug-in labeling plate bases (50 pieces in one pack) SERIES M - Auxiliary minicontactors - Technical data General Maximum number of contacts (MCR...) Rated thermal current (Ith) θ ≤ 60° (1) Rated operational voltage (Ue) acc. IEC 947.1 Insulation voltage (Ui) acc. IEC 947.1 Mounting positions 4 16A 660V 750V Conformity to standards IEC 947-1 IEC 947-5 BS 4794 EN 50002 NFC 63-140 CENELEC HD 420 CSA C22.2/14 EN 50005 VDE 0660 UL 508 NFC 63-110 EN 50011 SEMKO SETI DEMKO Lloyd’s Register (2) Bureau Veritas (2) RINA With the same pick-up and drop-out voltage With the same rated power Approvals UL CSA NEMKO – 7% of connection voltage + 4% of disconnection voltage With the same rated power Ambient conditions Storage temperature Operation temperature Altitude up to 3,000 m Altitude from 3,000 to 4,000 m Altitude from 4,000 to 5,000 m Terminal capacity – 55°C tot + 80°C – 40°C tot + 60°C Nominal values 90 % Ie 80 % Ue 80 % Ie 75 % Ue Terminal with M 3.5 screw (with pozidrive head and safety flange) Solid wire Flexible wire without terminal Flexible wire with terminal with cap Climatic resistance (IEC 68-2) Continuous tests 40 / 125 / 56 Cold (72 h) – Temperature – 40°C Dry heat (96 u) – Temperature + 125°C – Relative humidity < 50 % Humid heat (56 days) – Temperature + 40°C – Relative humidity 95 % Cyclical tests (6 cycles) Humid heat First half-cycle (12 h) – Low temperature – Relative humidity Second half-cycle (12 h) – Low temperature – Relative humidity Fast-on terminal 2.8 2 insulated terminals + 25°C 93 % + 55°C 95 % Shock resistance (IEC 68-2-27) Continuously closed (at 0.8 Us) Continuously opened (no voltage) Admissible acceleration Impulse duration Admissible acceleration Impulse duration 25 g 11 ms 20 g 11 ms Vibration resistance (IEC 68-2-6) Continuously closed (at 0.8 Us) Continuously opened (no voltage) Admissible acceleration 15 g Sweep between 10 - 200Hz Admissible acceleration 5g Sweep between 10 - 200 Hz (1) Terminal with wire 1.5 mm2 Ith = 16A / terminal with wire 1 mm2 Ith = 10A. Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ith = 8A acc. to DIN 46247 (2) In process Terminal for printed circuit (Ø of PCB hole) Ring terminal cap Fork terminal cap (mm2) (mm2) (mm2) (mm2) Tightening torque 0.8 Nm - 7 Lb-in 0.75 to 2 x 2 w. 0.75 to 2.5 x 2 w. 0.75 to 2.5 x 1 w. 0.75 to 1 x 2 w. (mm2) 1 x 2 w. 1.8 mm 7.8 mm 6.5 mm SERIES M - Auxiliary minicontactors - Technical data Control circuit Rated insulation voltage (Ui) (V) Standard voltages (Us) 50Hz (V) 60Hz (V) DC (V) Voltage (1) Operating limits xUs Drop-out xUs Consumption Pick-up (VA) Seal (VA) DC (W) Power factor Pick-up (cos ϕ) Seal (cos ϕ) Power dissipation (W) Opening and closing times Values between ± %Us % Making time at excitation NO (ms) Making time at desexcitation NC (ms) Breaking time at excitation NC (ms) Breaking time at desexcitation NO (ms) Values at Us Making time at excitation NO (ms) Making time at desexcitation NC (ms) Breaking time at excitation NC (ms) Breaking time at desexcitation NO (ms) Maximum time without voltage (ms) (without effecting the closed magnetic circuit) Mechanical endurance monofrequency #106 ops. dual-frequency #106 ops. DC #106 ops. Mamimum rate (no load) monofrequency # ops./h bifrequency # ops./h DC # ops./h MCRA... MCRC... MCRI... MCRK... 750 750 750 750 24 to 500 6 to 600 – – – 6 to 250 – – 24 – – 24 0.8 to 1.1 0.35 to 0.55 0.8 to 1.1 0.2 to 0.4 0.8 to 1.25 0.2 to 0.3 0.7 to 1.25 0.2 to 0.35 26 4 – – – 3 – – 1.2 – – 2 0.8 0.35 1.4 – – 3 – – 1.2 – – 2 80 to 110 6 to 13 8 to 16 5 to 11 6 to 13 80 to 110 22 to 36 9 to 12 18 to 27 5 to 7 80 to 125 30 to 70 9 to 16 20 to 45 5 to 9 70 to 125 20 to 50 9 to 16 18 to 35 5 to 9 7 to 12 8 to 16 6 to 10 6 to 13 3 24 to 27 9 to 11 20 to 26 5 to 8 3 25 to 45 9 to 16 25 to 35 5 to 9 3 25 to 40 9 to 16 20 to 30 5 to 9 3 15 10 – – – 10 – – 10 – – 10 9000 3600 – – – 9000 – – 9000 – – 9000 (1) Keeping the magnetic circuit open, coils are intrinsically protected against burning with voltage under closing values SERIES M - Auxiliary minicontactors - Dimensional drawings Three- and four-pole contactors Instantaneous auxiliary contact blocks J 20 MARN . . AT MCRA . . . AT ◆ MCRC . . . AT ◆ MCRI . . . ATD MCRK . . . ATD MARL1 . . AT, MARL1 . . ATS (1) AC-control (2) DC-control MARF4 . . AF MC0A . . . AF ◆ MC1A . . . AF ◆ MC0C . . . AF ◆ MC1C . . . AF ◆ MCRA . . . AI ◆ MCRC . . . AI ◆ Electronic timer block MREBC . 0AC2 MARL1 . . AF MARL1 . . AFS (1) AC-control (2) DC-control MARL1 . . AI MARL1 . . AIS Voltage suppressor block (1) Frontal mounting (2) Lateral mounting MP0A . AE . MP0C . AE3 (1) AC-control (2) DC-control