• Floating plates are positively locked in place during mold open and mold closing movements, eliminating mold crashes due to plates floating out of position
• Provide mold designers with a high degree of confidence that floating plates will be where they should be throughout the life of the mold
• Molders can run their molds with the assurance that plates will be positively, precisely positioned each and every time the mold opens and closes - allowing molders to confidently run molds faster
• Standard design simplifies mold design, while improving design flexibility
• Designed and engineered to hold large forces while mounted on the side of the mold - saving space in the interior of the mold
• Simple design reduces machining - saving machining time & effort
• Standardized components simplifies mold maintenance
• Eliminates springs & associated play in plates, and reduces mold maintenance
• Standard sizes to accommodate most mold base sizes and stroke lengths
• (4) sizes of Housings with (2) Housing lengths each; (3) Puller Bar lengths
• Puller Bars & Housing may be shortened by the mold maker as desired
• Stroke may be with or without delay
NEW
FAX: 800-845-3807
PHONE: 800-265-4885
WINDSOR: PHONE 519-737-6743 FAX 519-737-6744
External Latch Lock
Type SA
Catalog Number
SA(w1)-(L1)-(D1) x1 w2 L2 x2 W3 L3 X3 W4 D4 X4 D5 X5 W6 L6 X6 L7 L9 Stroke 1 w1 L1 DI
SA55-130-00 130 00
SA55-130-15
SA55-130-25
SA55-160-00
10.5
55
25
00
SA55-160-15
SA55-160-25 25
SA65-150-00 150 00
SA65-150-18
SA65-150-32
25 38.2 35 16.3 40 16 25 26 4 10 M8 10 16.4 15.4 17 12 65
32
00
SA65-200-18
SA65-200-32 32
SA80-200-00 200 00
SA80-200-25
SA80-200-50
30 49.2 42 19 52 20 30 32 5 12 M10 12 20.4 16.4 20 14 80
50
00
SA80-250-25
SA80-250-50 50
SA95-250-00 250 00
SA95-250-30
SA95-250-55
36 62.2 54 24 66 27 38 40 6 15 M12 14 25.4 23 25 16 95
55
00
SA95-300-30
SA95-300-55 55
EXAMPLE without delayed stroke sequence
External Latch Lock
Type SA
EXAMPLE with delayed stroke sequence
SA..PU is a shock absorber, buffer damper.
DI
Sz
Maximum delayed stroke.
Switching zone, Stroke 2 starts slightly before the end of Stroke1.
Backlash The segments need some clearance/
TF
LF play to allow the locking/unlocking sequence. (Built in the product/ design.)
Traction force (always try to keep the lowest possible force at release sequence).
Locking force (maximum locking force after Stroke 1).
W1
(2 pcs)
55
65
80
95
Intended TF max LF max mold size (Traction Force) (Locking Force)
246 x 246
396 x 396
646 x 646
796 x 796
20 kN
35 kN
50 kN
80 kN
1.5 kN
2.0 kN
3.0 kN
4.0 kN
Sz Backlash
2.0
2.3
2.7
3.2
0.25
0.25
0.30
0.35
INSTALLATION EXAMPLE
w1 w3 x3 w4 d4 x4 d5 x5 R w10 d10 L10 M1
55 34 23 22 4 10 M6 7 5 42 6 43.35
65 40 25 26 4 10 M8 10 5 50 8 47.25
80 52 30 32 5 12 M10 12 6 62 8 56.3
95 66 38 40 6 15 M12 14 7 76 10 M8
i. Please make sure the assembly surfaces are parallel, on the same level (clear up to max 0,2mm is allowed) and perpendicular to the guide holes.
ii. Position the housing (SA..- ...HS), drill the holes and cut the length if needed.
iii. Position the puller bar (SA..- ...PB), drill the holes and cut the length if needed.
INSTALLATION EXAMPLE without delayed stroke
INSTALLATION EXAMPLE with delayed stroke
NOTE!
Puller bar (SA..- ‐..PB) can only be inserted into Latch Lock
(SA..- ‐..LL) when the
Latch Lock are in correct position.