SPECIFICATIONS ABBREVIATIONS LEGEND TELEPHONE OUTLET AT 18" AFF EK DATA OUTLET AT 18" AFF DATA / PHONE OUTLET AT 18" AFF CABLE TV OUTLET AT 18" AFF TV S SINGLE POLE SWITCH AT 48" AFF S3 3-WAY SWITCH AT 48" AFF SD DIMMER SWITCH AT 48" AFF SM MOTION SENSOR SWITCH (MANUAL ON / AUTOMATIC OFF) AT 48" AFF ERIC KNUTSON architect 2231 H STREET SACRAMENTO,CA 95816 SINGLE OUTLET AT 18" AFF DUPLEX OUTLET AT 18" AFF GFI 925-324-0587 eric@knutsonarchitecture.com www.knutsonarchitecture.com DUPLEX OUTLET, GROUND FAULT INTERRUPTER AT MIN 18" AFF DUPLEX OUTLET MOUNTED ABOVE BASE CABINET DOUBLE DUPLEX OUTLET AT 18" AFF R RANGE OUTLET AT 18" AFF WP OUTLET WITH WATER-PROOF COVER AT 18" AFF v h n FLOOR OUTLET CEILING MOUNTED OUTLET ELECTRICAL PANEL TIMER CLOCK MOTOR CONNECTION DISCONNECT SWITCH SHEETNOTE TAG LED EXIT LIGHT AND EM LIGHT COMBO WITH BATTERY BACKUP LIGHT FIXTURE TAG BUILDING STANDARD STROBE/HORN BUILDING STANDARD STROBE FIRE ALARM MANUAL PULL STATION EMERGENCY LIGHT W/ BATTERY BACK UP GENERAL NOTE: WALL MOUNTED ELECTRICAL SWITCHES AND OUTLETS SHALL BE LOCATED NO MORE THAN 48INCH TO THE TOP OF BOX, NOR LESS THAN 15INCH TO THE BOTTOM OF BOX ABOVE FINISHED FLOOR. DATE: ISSUE: 1 02.13.14 REVISIONS 2 02.24.14 BID SET 3 06.01.12 PERMIT SET SPECIFICATIONS, ABBREVIATIONS AND LEGEND DATE: 150 8TH STREET SAN FRANCISCO, CA 94103 PH. (415) 512-7141 FAX (415) 512-7120 SCALE: DRAWN: E0.10 EK ERIC KNUTSON architect 2231 H STREET SACRAMENTO,CA 95816 925-324-0587 eric@knutsonarchitecture.com www.knutsonarchitecture.com v h n DATE: ISSUE: 1 02.13.14 REVISIONS 2 02.24.14 BID SET 3 06.01.12 PERMIT SET LIGHTING TITLE 24 PART I DATE: 150 8TH STREET SAN FRANCISCO, CA 94103 PH. (415) 512-7141 FAX (415) 512-7120 SCALE: DRAWN: E0.20 EK ERIC KNUTSON architect 2231 H STREET SACRAMENTO,CA 95816 925-324-0587 eric@knutsonarchitecture.com www.knutsonarchitecture.com v h n DATE: ISSUE: 1 02.13.14 REVISIONS 2 02.24.14 BID SET 3 06.01.12 PERMIT SET LIGHTING TITLE 24 PART II DATE: 150 8TH STREET SAN FRANCISCO, CA 94103 PH. (415) 512-7141 FAX (415) 512-7120 SCALE: DRAWN: E0.21 5.33 6.67 TABLE 48 X 30 TABLE 48 X 30 TABLE 48 X 30 TABLE 48 X 30 TABLE 48 X 30 EK ERIC KNUTSON architect 2231 H STREET SACRAMENTO,CA 95816 TABLE 36 X 36 TABLE 36 X 36 TABLE 36 X 36 925-324-0587 eric@knutsonarchitecture.com www.knutsonarchitecture.com TABLE 48 X 30 TABLE 42 X 30 TABLE 42 X 30 31 RICE RICE TABLE 48 X 30 PLATES TABLE 48 X 30 TABLE 48 X 30 v TABLE 48 X 30 28 25 h n GRINDER 33 FLR. DRAIN GRINDER 24 18 12 ESPRESSO MACHINE 37 48 X 18 48 X 18 48 X 18 48 X 18 CONV. OVEN 13 30 TABLE 42 X 30 1 TABLE 42 X 30 3 2 29 4 WALK IN COOLER WALK IN FREEZER H/W FLR. DRAIN U/C FRIDGE 48 X 18 JUICER 27 48 X 18 26 TABLE 48 X 30 5 BLNDR 7 48 X 18 48 X 18 48 X 18 BLNDR 32 DOUGH MIXER 41 POS 6 U/C ICE MACHINE 23 21 17 D/W TABLE 48 X 30 32 22 16 ICE CREAM FREEZER POS 14 15 12 +12" 8 40 40 FLR. DRAIN 11 39 PASS THROUGH 9 38 35 +12" 10 36 FLR. DRAIN JUICER SLICER 9 37 OFFICE 8 SHEETNOTES 1. CIRCUIT NUMBERS ARE SCHEMATIC AND SHOW THE DESIGN INTENTION AND LOAD BALANCE REQUIREMENTS. CONTRACTOR SHALL INDICATE ACTUAL CIRCUITS USED ON AS-BUILT DRAWINGS AND PANEL DIRECTORY. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ELECTRICAL CHARACTERISTICS AND ADDITIONAL REQUIREMENTS FOR ALL THE ELECTRICAL FOOD SERVICE EQUIPMENT, INCLUDING OUTLET, PLUGS AND ANY EXTERNAL OR INTERNAL WIRING AND COMPLY AS REQUIRED. SEE ALL FOOD SERVICE DESIGN CONSULTANT'S DRAWINGS FOR EQUIPMENT SCHEDULE AND REQUIREMENTS. J 5. ALL 125V, SINGLE PHASE 15 AND 20 AMPERE RECEPTACLES INSTALLED WITHIN FOOD PREP. AND SERVICE AREA SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL. ~ (N) PANEL"H" 7 8 (N) PANEL"A" GREASE TRAP STORAGE (N) TELE/DATA PANEL BY OTHERS ADD. DR. AS REQ'D 20 ~ FLR. DRAIN FLR. SINK- TYP. +12" 3. THE MOUNTING HEIGHT FOR ALL ELECTRICAL DEVICES SHALL BE VERIFIED WITH OWNER BY CONTRACTOR. 4. CONTRACTOR SHALL VERIFY NEMA CONFIGURATION FOR ALL EQUIPMENT OUTLETS PRIOR TO INSTALLATION. FURNISH AND INSTALL RECEPTACLE AND/OR J-BOX TO MATCH EQUIPMENT CONNECTION. ELECT. SUB PANEL +12" RICE +12" 1 2 3 4 3 5 6 6. CONTRACTOR TO VERIFY THE LOCATION OF ALL MECHANICAL/PLUMBING EQUIPMENT FROM MECHANICAL/PLUMBING DRAWINGS PRIOR TO INSTALLING ELECTRICAL CONNECTION FOR MECHANICAL/PLUMBING EQUIPMENT. 7. FURNISH AND INSTALL PHONE/DATA OUTLET AND 1/2 CONDUIT TO TELE/COM TERMINAL IN OFFICE. WIRING AND TERMINATION BY OTHER. 8. FURNISH AND INSTALL BACKBOX AND CONDUIT TO BUILDING EXISTING FIRE ALARM PANEL FOR FIRE ALARM DEVICES. 9. FIRE ALARM SYSTEM IS DESIGN BUILD BY FIRE ALARM CONTRACTOR. FA CONTRACTOR TO PROVIDE AND SUBMIT ALL CALCULATION. SHOP DRAWINGS REQUIRED BY THE SAN FRANCISCO FIRE INSPECTION DEPARTMENT. DATE: ISSUE: 1 02.13.14 REVISIONS 2 02.24.14 BID SET 3 06.01.12 PERMIT SET 1 POWER AND SIGNAL PLAN - GROUNG FLOOR SCALE: 1/8" = 1' 0" ELECTRICAL PLAN GROUND FLOOR DATE: NON-INFRINGEMENT STATEMENT THE SCOPE OF TENANT IMPROVEMENT WORK AS SHOWN ON THIS PLAN SHALL NOT INFRINGE ON THE EXISTING SMOKE CONTROL AND LIFE SAFETY SYSTEM. 150 8TH STREET SAN FRANCISCO, CA 94103 PH. (415) 512-7141 FAX (415) 512-7120 SCALE: DRAWN: E1.00 EK ERIC KNUTSON architect 2231 H STREET SACRAMENTO,CA 95816 925-324-0587 eric@knutsonarchitecture.com www.knutsonarchitecture.com v 1 h n POWER AND SIGNAL PLAN - SECOND FLOOR SCALE: 1/8" = 1' 0" DATE: ISSUE: 1 02.13.14 REVISIONS 2 02.24.14 BID SET 3 06.01.12 PERMIT SET ELECTRICAL PLAN SECOND FLOOR DATE: NON-INFRINGEMENT STATEMENT THE SCOPE OF TENANT IMPROVEMENT WORK AS SHOWN ON THIS PLAN SHALL NOT INFRINGE ON THE EXISTING SMOKE CONTROL AND LIFE SAFETY SYSTEM. 150 8TH STREET SAN FRANCISCO, CA 94103 PH. (415) 512-7141 FAX (415) 512-7120 SCALE: DRAWN: E1.10 EK LIGHTING/ ELECTRICAL LEGEND 5.33 NOTE: ROUGH ELECTRICAL BY LANDLORD INCLUDING BUT NOT LIMITED TO TRANSFORMER, PANEL, BREAKERS, J-BOXES, SWITCH BOXES, CONDUIT RUNS & WIRE PULLS FINISH ELECTRICAL INCLUDING BUT NOT LIMITED TO OUTLETS, LIGHTING FIXTURES & LIGHTING CONTROLS BY TENANT 6.67 3 OS D SINGLE POLE SWITCH DIMMER SWITCH ERIC KNUTSON architect 2231 DUPLEX RECEPTACLE STREET SACRAMENTO,CA 95816 OCCUPANCY SENSOR SWITCH LEVITON ODS15-1DW- WHITE SINGLE 3-WAY SWITCH H 925-324-0587 eric@knutsonarchitecture.com www.knutsonarchitecture.com SPECIAL PURPOSE RECEPTACLE 220 V COFFEE GRINDERS- VERIFY NEMA CONFIGURATION 3 F A SURFACE MOUNT UTILITY 23 W CFL BULBED FIXTURE T.B.D. B RECESSED CEILING FIXTURE5" ELCO EL5LVICA W/ MR16 BULB 25W MAX. OR EQIV. C MONOPOINT PENDANT 23 W CFL BULBED FIXTURE TRACK/ RAIL SYSTEM T.B.D. C MONOPOINT LED PENDANT 5 W BULBED FIXTURE TRACK/ RAIL SYSTEM T.B.D. D C F WALL MOUNTED LENSED FLUORESCENT, DOWNLIGHT 1 LAMP 32 WATT T8, 4'-0" LENGTH DAMP LOCATION, LENSED NULITE DWM-2-32-TB-UNV-IS-N-WH-DL G1 B C FLUSH CEILING GRID- MOUNTED FLUORESCENT 3 LAMP, 2' X 4', 86 W G3 CEILING HUNG LENSED FLUORESCENT 1 LAMP 28T5, 4'-0" LENGTH, LENSED NULITE DH2-28T5-UNV-IS-N-LAC-LV1, 32 W G4 C C C 1 C J 2 n EXIT SIGN- BY LANDLORD LITHONIA EDGE LIT ON CLEAR ACRYLIC W/ WHITE END CAPS AND MOUNTING BRACKETS TO BE LIGHTED AT ALL TIMES OF OCCUPATION C C h LED PENDANT 12 W BULBED FIXTURE TRACK/ RAIL SYSTEM T.B.D. E B v UNDERCOUNTER HALO STRIP/ UNIT LIGHTING JS LED 12 V JE-OO4W04 B OVER- CANOPY HALO STRIP/ UNIT LIGHTING 21" 13 W CONTINUOUS T5 MINI WARM WHITE BI-PIN FLOURESENT TUBES EXHAUST FAN CEILING MOUNTED B C JUNCTION BOX CEILING MOUNTED K TRANSFORMER CEILING MOUNTED WAC LM-EN12-300M 12V 300W BN B C C J C C B G3 A B B C C A G1 SHEETNOTES B G3 B G3 1. CIRCUIT NUMBERS ARE SCHEMATIC AND SHOW THE DESIGN INTENTION AND LOAD BALANCE REQUIREMENTS. CONTRACTOR SHALL INDICATE ACTUAL CIRCUITS USED ON AS-BUILD DRAWINGS AND PANEL DIRECTORY. G1 G3 C G3 C 3. FURNISH AND INSTALL EMERGENCY LIGHTS AND EXIT LIGHTS WITH BACKUP BATTERY TO ILLUMINATE FOR AT LEAST 90 MINUTES IN CASE OF POWER FAILURE. 4. FURNISH AND INSTALL NEW WALL MOUNTED BUILDING STANDARD OCCUPANCY SENSOR WITH INTEGRATED SWITCH. C C 2. FURNISH AND INSTALL NEW LIGHTING FIXTURE AND CONNECT TO CIRCUIT IN THE AREA AS INDICATED. A 5 B C B C A G3 G3 G3 G3 5. FURNISH AND INSTALL NEW WALL MOUNTED BUILDING STANDARD DIMMER SWITCH. FIXTURES SHALL BE DIMMABLE TYPE. D OS OS C B 4 DATE: ISSUE: A 1 02.13.14 REVISIONS B G4 2 02.24.14 BID SET G4 3 06.01.12 PERMIT SET (N) PANEL"A" F LIGHTING PLAN DATE: NON-INFRINGEMENT STATEMENT THE SCOPE OF TENANT IMPROVEMENT WORK AS SHOWN ON THIS PLAN SHALL NOT INFRINGE ON THE EXISTING SMOKE CONTROL AND LIFE SAFETY SYSTEM. 150 8TH STREET SAN FRANCISCO, CA 94103 PH. (415) 512-7141 FAX (415) 512-7120 SCALE: DRAWN: E2.00