PBR and Standard Permit Emission Limits Impacts Analysis Not Required if Total Emissions Less Than Limit of PBR Level 1 (180 day post construction registration) Limit of PBR Level 1 (90 day post construction registration) Limit of PBR Level 2 (preconstruction registration) Limit of Standard Permit (preconstruction registration) NOx 9 lb/hr 9 25 lb/hr tpy 25 100 lb/hr tpy 50 250 lb/hr tpy 53 250 lb/hr tpy H2S 0.025 lb/hr 0.5 2.2 lb/hr tpy 2 4.5 lb/hr tpy 6 9 lb/hr tpy 6 15 lb/hr tpy SO2 0.42 lb/hr 5.4 10 lb/hr tpy 8 15 lb/hr tpy 12 25 lb/hr tpy 12 50 lb/hr tpy CO impacts analysis never required lb/hr 11.4 50 lb/hr tpy 22.8 100 lb/hr tpy 57 250 lb/hr tpy 57 250 lb/hr tpy impacts analysis never required - 0.5 tpy 1 tpy 2 tpy not specified, dictated by benzene, toluene, xylene 25 5 lb/hr tpy 50 10 lb/hr tpy 75 25 lb/hr tpy 200 250 lb/hr tpy impacts analysis never required - 0.9 lb/hr 1.5 lb/hr 2 lb/hr 3 10 lb/hr tpy PM2.5and10 Total VOC formaldehyde 4 tpy benzene 0.013 lb/hr 0.8 1.2 lb/hr tpy 1.8 2.5 lb/hr tpy 2.25 3.5 lb/hr tpy 20 10 lb/hr tpy toluene 0.146 lb/hr 3.1 lb/hr 6 lb/hr 7 lb/hr 35 10 lb/hr tpy xylene 0.08 lb/hr 1.7 4 lb/hr 19 10 lb/hr tpy lb/hr 3 lb/hr Note 1: To explain the information on this chart - xylene is taken as an example. The first column shows that if total site-wide xylene emissions are less than 0.08 lb/hr, no impacts analysis is required to be performed. The next four columns show the xlylene emission limits for each authorization level - Level 1 (180 day post construction registration), Level 1 (90 day post construction registration), Level 2 (preconstruction registration), and Standard Permit (preconstruction registration). If total site-wide xylene emissions are less than 1.7 lb/hr, then xylene emissions fall within the limit of PBR Level 1 (180 day post construction registration). If total site-wide xylene emissions are equal to or greater than 1.7 lb/hr and less than 3 lb/hr, then xylene emissions fall within the limits of PBR Level 1 (90 day post construction registration). If total site-wide xylene emissions are equal to or greater than 3 lb/hr and less than 4 lb/hr, then xylene emissions fall within the limit of PBR Level 2 (preconstruction registration). If total site-wide xylene emissions are equal to or greater than 4 lb/hr and less than 19 lb/hr, then xylene emissions fall within the limit of the Standard Permit (preconstruction registration). Note 2: The site is required to use the highest level of authorization applicable based on the levels the pollutant emissions fall into. For example, if xylene emissions are 1.5 lb/hr, which is below the limits of PBR Level 1 (180 day post construction registration), but NOx emissions are 30 lb/hr, which is greater than the limits of PBR Level 1 (180 day post construction registration), but below the limits of PBR Level 2 (preconstruction registration), then the site must be authorized under PBR Level 2 (preconstruction registration), assuming none of the other pollutant emissions exceed the limits of this level.