: ANT ELECTRONIC CO., LTD NINGBO,CHINA Tel: 86

advertisement
8. Guarantee
The guarantee is 18 months. In guarantee period, ANT repair or change the
damaged goods for the original buyer..
The buyer offers the damaged evidence and ANT offer the new one or new
components after checking the fault.
ANT do not have responsibility to the damaging caused by improper using,
accident or negligence.
ANT ELECTRONIC CO., LTD
NINGBO,CHINA
Tel: 86-0574-87164103
Fax::
86-0574-87150953
Http: www.ant-china.com
Email: ant@ant-china.com
888@ant@ant-china.com
ANT Electronic Co., Ltd possesses the copyright
1
5. System configuration and accessories
Beam number: 154
21.5
1
1
10
10
Cable strip 10cm
Bolt, nut, washer
Power supply
10
420
240
7. Size and installation
420
One transmitter shielded after 120s
detected absent.
3. Installation
4
2000
10
1
6.Redundancy
Output voltage: 2X12V
Rated power: 5W
Relay: 1A, 125VAC/2A,30VDC
Operating tem.: -20℃~85℃
Size: 154X50X31mm
5-
2000
√
Manual
Guarantee
Adhesive disk
Cable clip R
21.5
4
420
2.2 Power supply
5-
310
5.4 Optional accessories
310
Voltage: 12VDC
Power: ≤5W
Response time: 61ms
Highest beam: 1860mm
Lowest beam: 25mm
Protection distance: 0~5m
Allow error: Alternative LED
Protection grade: IP 65(moisture proof)
CSN515
420
5.3
2.1 Detector
Input voltage:
AC65~285V
AC/DC16~65V
Model
5.2 Sensor number: 32 pairs
420
2. Technical parameter
5.1 System type
420
The system include the emitter and receiver, power supply box, flexible cables.
When the power is turned on, there will generate infrared screen between two
doors. If any ray of infrared is blocked by any object or person, the doors stops
closing immediately and open to protect people.
240
1. Principle
Controller
3.1 Installation
Put the detector on the door edge, 10mm away from the bottom.
Mark the fixing holes on the door edge.
Move away the detector and drill 4mm holes on the edge.
Fix the detector with fixers in accessory bag.
Connect two cables with power supply: model 368.
9.3
9.3
Picture 1
3.2 Sectional view(Pic 1)
3.3 Installation figure(Pic 2)
Caution
4. Fault detection and solution
INDICATOR
Green
Green
Caution
Cable
4.1 Mode 368 power supply
PROBLEM
SOLUTION
Green LED is No power supply
not lighted
Green LED is The beam is blocked or problems with the detector
lighted
Orange Orange LED is System is normal
lighted
Avoid strongly bending
or twisting the cables.
Detector
Compulsory
Door
Compulsory The power to the controller
is the same with the lighting
power in car.
Installation drawing
Picture 2
Light
No light
System is normal
12 5
138
Picture 3
2
3
4
2-φ
Single ray is blocked
T RA VELL ING C ABLE I NP U T
functionof the system.
Light
Flash
RELAY OUTPUT
N C NO CO M
The ray is blocked,The buzzer gets into alarm condition after
15 sencond' continuous blocking
Please ground the control
box with good conductive
!
earth wire to improve the
Caution light resistance and the
S TA TU S
The signal of emitter and receiver is open/The zero line is open
AC 65~285V
Wrong connection
POWER INPUT
SOLUTION
N
Both are not
lighted
Flash
No light
Both are
lighted
L
INDICATOR PROBLEM
50
4.2 Receiver
Download