Mobile 24 Dehumidifiers 25 Heat pump water heater Hot

advertisement
Mobile
24
Dehumidifiers
25
Heat pump water heater
Hot Water 190C
Hot Water 300A
26
27
Heat exchanger
29
23
Mobile
TMCZ 105 F
Cooling, heating effect and dehumidification.
Cooling capacity: 3.0 kW.
LED display.
4 air ventilation speeds (during cooling).
Timer function for on delay (in hours).
Timer function for off delay (in hours).
Sleep feature for night-time function.
Infrared remote control.
Window slide kit.
Dual condensate drain modes.
Extendable corrugated pipe with inner recovery.
Model
Power supply
Nominal capacity in cooling mode
Rated power input for cooling
Rated energy efficiency index
Energy efficiency class in cooling mode
Energy consumption for equipments with single duct cooling function
Nominal capacity in heating mode
Rated power input for heating
Coefficient of nominal efficiency
Energy efficiency class in heating mode
Energy consumption for equipments with single duct heating function
Sound power level
Sound pressure level
Refrigerant
Global warming potential
Dimensions
Net weight
Dehumidifying capacity
Air flow
Air exhaust flexible pipe
24
TMCZ 105 F
Prated for cooling
PEER
QSD
Prated for heating
PCOP
QSD
LWA
GWP
(WxHxD)
Ph-V-Hz
kW
kW
EERd
kWh/h
kW
kW
COPd
kWh/h
dB(A)
dB(A)
Type
kgCO2 eq.
mm
kg
L/h
m3/h
mm (Ø)
mm (Length)
1-220~240-50
3,00
1,20
2,60
A
1,10
3,00
1,00
3,10
A++
0,80
62
52
R410A
1975
300x778x505
28
4,6
400
150
210~1400
Dehumidifiers
DT16-A1 - DT80-A1
Residential dehumidifying (16 L/day).
R134A refrigerant.
LED display.
2 air ventilation speeds.
Timer function for on delay (in hours).
Timer function for off delay (in hours).
Digital hygrostat for detecting and controlling humidity.
Possibility of setting desired humidity level.
2.50 L tank.
Possibility of continuous drainage.
DT16-A1
Large capacity dehumidification (80 L/day).
R410A refrigerant.
LED display.
2 air ventilation speeds.
Timer function for on delay (in hours).
Timer function for off delay (in hours).
Digital hygrostat for detecting and controlling humidity.
Possibility of setting desired humidity level.
9.00 L tank.
Possibility of continuous drainage.
DT80-A1
Model
Power supply
Nominal capacity of dehumdifying
Control
Type of defrost
Defrosting
Humidity detection and control
Consumption
Sound pressure level
Air flow
Current intensity
Capacity of the tank supplied
Range of use
Refrigerant
Dimensions
Net weight
(30° C RH80%)
(WxHxD)
Ph-V-Hz
lt/day
W/h
dB(A)
m3/h
A
L
°C
Type
mm
kg
DT16-A1
DT80-A1
1-220~240-50
16
Electronic
Fan
Automatic
Digital hygrostat
410
42
126
1,80
2,50
5° ~ 35°
R134A
365x490x215
13,2
1-220~240-50
80
Electronic
Fan
Automatic
Digital hygrostat
1100
48
135
5,00
9,00
5° ~ 35°
R410A
300x625x505
21
25
Heat pump water heater
TWMI 190C
65° C max temperature of domestic hot water.
Actual COP 3.50.
Wide range of operating ambient temperatures: 5° ~ 43° C.
Speed of reaching heating capacity with cold start: 260 minutes (with incoming
water temperature of 15° C, outgoing water temperature of 45° C and ambient
temperature of 15° C).
Minimum tank dispersions: -2.2° C in 24 hours with ambient temperature 15° C and
average temperature of the tank of 43° C.
Anti-legionella function: 70° C (activating the electrical resistor).
Customisable programming: timer for time bands, very useful in case of reduced
rates at night.
Model
TWMI 190 C
Operating Mode
Operating Range
Power supply
Total Tank Capacity
Electric Heater
Noise level
Dimensions (DxH)
Weight
Refrigerant Gas (Type/Quantity)
Hydraulic pipeline
COP*
COP DHW**
Tank Dispersion 24/h (43°C Average temp.)
Full Heating Capacity (Inlet Temp. 15°C / Output temp. 45°C)
Max. hot water available during rapid tank emptying
Full Heating Capacity Power consumption
Hourly Absorption
Heat Pump
+5°C~+43°C
220~240V-1ph-50Hz
190
1,00
48
ø568x1580
101
R134A/0,80
DN20
3,50
2,76
2,2° C
260
157 (min. 40,4° C)
2,0
0,42
L
kW
dB(A)
mm
kg
kg
mm
W/W
W/W
°C
min.
L
kWh
kWh
* (Air 15/12 °C - Water 15/45 °C); ** (EN 16147 tapping cycle “L”).
Maximum temperature of hot water produced: with 65° C max compressor for 5°~43° C outside. With 70° C max electrical resistance for -30°~43° C outside.
HYDRAULIC CONNECTIONS DIAGRAM
Domestic hot
water appliances
Condensate drain
Safety
valve
Vent valve
Hot water
outlet
Recirculation
Cold water inlet
Tank
discharge
26
Water supply
TWMI 300A
Domestic hot water from 45° C to 60° C only when the heat pump is operating.
Actual COP 3.41
Wide range of operating ambient temperatures: 7°~ 43° C.
Speed of reaching heating capacity with cold start: 203 minutes with incoming
water temperature of 15° C, outgoing water temperature of 45° C and ambient
temperature of 15° C.
Minimum tank dispersions: -1.8° C in 24 hours with ambient temperature 15° C and
average temperature of the tank 43° C.
Anti-legionella function: the built-in DHWT-IHA kit is programmed to activate a
periodic weekly cycle that brings the water temperature to 70° C (through the use of
the electrical resistor).
Customisable programming: timer for time bands, very useful in case of reduced
rates at night.
Defrost function: all the units are equipped with automatic defrost valves.
Integrated heat exchanger for additional solar system.
Model
Operating Mode
Operating Range
Power supply
Total Tank Capacity
Electric Heater
Noise level
Dimensions (DxH)
Weight
Refrigerant Gas (Type/Quantity)
Hydraulic pipeline
COP*
COP DHW**
Tank Dispersion 24/h (Average temp. 43° C)
Full Heating Capacity (Inlet Temp. 15° C / Output temp. 45° C)
Max. hot water available during rapid tank emptying
Full Heating Capacity Power consumption
Hourly Absorption
Built-in heat exchanger
TWMI 300 A
Heat Pump
-7° C~+43° C
220~240V-1ph-50Hz
300
1,50
46,6
ø650x1920
123
R134A/1,20
DN20
3,41
2,98
1,8° C
203
293 (min. 40,1° C)
2,90
0,88
0,7
L
kW
dB(A)
mm
kg
kg
mm
W/W
W/W
°C
min.
Lt
kWh
kWh
m3
* (Air 15/12 °C - Water 15/45 °C); ** (EN 16147 tapping cycle “L”).
Maximum temperature of hot water produced: with 60° C max compressor for 7°~43° C outside, 55° C max for 2°~7° C outside, 50° C max for -2°~2° C outside, 45° C
max for -7°~-2° C outside. With 60° C max electrical resistance; 70° C for anti-legionella cycle.
4 METHODS OF INSTALLATION
30Pa static pressure allows ducts up to 10 metres (max 5 bends) for conveying cold water to the outside, or inside of
rooms to be cooled during summer time.
air intake
air outlet
This connection
allows the
introduction of fresh
air into the room
AIR OUTLET
WITH DUCTING
air intake
air
outlet
AIR INTAKE
WITH DUCTING
air outlet
air intake
air
outlet
AIR INTAKE AND
OUTLET WITH DUCTING
air intake
WITHOUT
DUCTING
This connection
allows the
introduction of fresh
air into the room
27
TWMI 300A
HYDRAULIC CONNECTIONS DIAGRAM
l
So
ar
e
th
Domestic hot water
appliances
rm
al
l
co
or
ct
le
s
Condensate drain
Safety
valve
Hot water
outlet
Magnesium
anode
Vent valve
Solar thermal temperature
sensor
Recirculation
Pump
Built-in heat exchanger outlet
Built-in heat exchanger inlet
Tank
discharge
28
Cold water inlet
Water supply
Heat exchanger
ETIN 201~1001 - ETIS 1501~380V
8 power levels: 200~2000 m3/h.
Compact size and ultra lightweight.
Low acoustic impact: only 27 dB(A) for 200 m3/h model.
Wired remote control supplied standard.
ETIN 201~1001
The ventilation units with heat recovery are suited for use in
bars, offices, gyms, changing rooms and all spaces where
it is necessary to circulate the air due to the presence of
polluting or toxic substances.
The units consist of two centrifugal fans: one introduces
clean air filtered from outside and one expels the stale air
from the inside.
The two air flows go through one blade heat exchanger
in which part of the heat is recovered. The indoor air heats
or cools the outdoor air that is introduced without coming
into contact with it.
Indoor
ETIS 1501~2001 380V
Outdoor
Fresh air
Air expelled
outdoors
Dividing
septum
Separator
Outdoor
fresh air
Stale air intake
Model
Power supply
Power input
Input Rated Current
Air flow
Available Static Pressure
Enthalpy exch. Efficiency (winter)(*)
Enthalpy exch. Efficiency (summer) (*)
Body size
(DxHxW)
Flange
diameter/depth
Net
Max Noise level 1,5 m
Max Noise level 2,5 m
Ph-V-Hz
W
A
m3/h
Pa
%
%
mm
mm
kg
dB(A)
dB(A)
(*) Following ENV 308 rule
Outdoor air
WINTER
Heating
Indoor air
ETIN 201
ETIN 301
20
0,5
200
40
0,56
300
75
55
666x264x655
22
27
20
DB
-5°C
20°C
744x270x599
ø144/100
23
30
23
Relative humidity
80%
50%
ETIN 401
ETIN 501
1-220~240-50
80
120
1
1
400
500
80
744x270x804
30
32
25
824x270x904
ø194/100
35,5
35
28
ETIN 801
ETIN 1001
360
2
800
2,4
1000
100
60
ETIS 1501
ETIS 2001
3-380~415-50
900
1100
3,2
3,6
1500
2000
160
170
50
1116x388x884 1116x388x1134 1500x540x1200 1550x540x1400
ø242/100
370x350/50
57,5
59
160
175
39
40
51
53
32
33
44
46
(*) Following ENV 308 rule
Outdoor air
SUMMER
Cooling
Indoor air
DB
32°C
26°C
Relative humidity
50%
50%
29
30