Strip Fixture Retrofit Pre-Assembled (PA) Kit.qxd

advertisement
Retrofit
Strip Fixture Pre-Assembled (PA) Kit
Series
Features
Pre-Wired and Assembled Brackets, Ballasts,
Luminaire Disconnects and Accessories
Available in a Range of Lamp, Ballast and Accessory
Configurations
Accepts ESI reflectors for Tool Free Installation and
Removal
Fits Most Strip Fixtures (4.25” or 5.00” channel widths)
Technical Data
Socket Bars: 0.028” pre-painted cold-rolled
steel. Prepunched for lampholders and wire
passageway. Tabs on socket bars securely
mount the reflector in the correct position
relative to the lamps. Note: ESI’s optional
uni-bracket is pictured in the diagrams.
Reflector: The reflector can be ordered with an
85% reflective anodized finish, a 95% reflective
enhanced or film finish, or a 92% reflective white
enamel. The substrate is 0.020” high quality aluminum. The reflector profile is optimized using
computer analysis and manufactured using state
of the art CNC equipment. A protective premask
is applied to all reflective surfaces prior to manufacture.
Installation: For retrofit, the existing ballast covers, ballast and socket bars are removed. With the new ballast
and optional accessories installed, the ESI socket bars
are attached to the existing channel with self-tapping
screws. The reflector is positioned between the socket
bars and attached with quarter-turn fasteners.
**NEW** Versa-Form Socket-Bar Set
(4.25” or 5.00” Variable)
Reflector Profiles
12” Refl. Profile (12S)*
8” Refl. Profile(8S)*
10.000”
6” Refl. Profile (6S)*
7.625”
12” Asymmetric (12A)*
5.125”
9.500”
5.000”
4.25”
*Dimensions subject to change. Available in a 1Lamp and 2Lamp Cross-section
Highlights
Save Time and $ on Installation
Easy to Install
Helps Eliminate Errors
Helps Assure Consistent Installation
Allows the Use of More Complex
and Value-added Technology
Meets or Exceeds
1598 Standard
Energy Solutions International
Retrofit
Strip Fixture Pre-Assembled (PA) Kit
Series
Options (this is a sampling of the options available, consult factory if you require options that are not listed)
Ballast
UNV(H,N,L)
DLU
Instant Start, High Efficiency Electronic Ballasts (High Ballast Factor, Normal Ballast Factor, Low
Ballast Factor)
Programmed Start, High Efficiency Electronic Ballasts (High Ballast Factor, Normal Ballast Factor,
Low Ballast Factor)
Daylight Harvesting Universal Voltage Ballast
Other
DS
ESTS
LC2R
Dual-Switching Wiring
Electronic Switch Allowing Multiple Ballast Control w/ one Wall Switch
Wireless Fixture Control Node (Switching, Dimming)
PS(H,N,L)
Sample Specification
The kit shall consist of socket bars (solid 0.028" min thickness, cold rolled steel pre-punched for lampholders)
with pre-installed and pre-wired fluorescent lampholders appropriate to included and pre-wired ballast(s), luminaire disconnect(s) and accessories. Also included shall be a hardware pack which contains self-tapping screws,
clips and related hardware required to mount and secure kit components to the existing fixture housing.
Ordering Information
Part Number = Fixture Size + Lamp Type + # Lamps + Style + Ballast + Options + Packaging
(Example K-1802VKTWUNVH-PA = 1’x8’ Retrofit Kit for two T8 lamps, prewired and assembled with a high lumen ballast)
Size
Lamp Type
# Lamps
Style
Ballast
Options
Packaging
K-14 - 1’ x 4’
0 - T8
2
VKTW
UNVH
See Section Above
BX - Individually Boxed
K-18 - 1’ x 8’
1 - T5
4
2 - T5HO
UNVN
PA - Pre-assembled*
UNVL
* Pre-wired, bulk packed ballast
and socket bar assemblies with
electrical disconnect
PSN
(OPTIONAL REFLECTOR) Part Number = Reflector Size + Material + Design
Size
R-14 - 1’ x 4’
Material
Design
EA - Enhanced Alum
6S - Small Profile
WR - White Enamel
8S - Standard Profile
12S - Wide Profile
12A - Asymmetric Profile
(888) 308-9197
Energy Solutions International
Download