jps nicheless led lights

advertisement
JPS NICHELESS LED LIGHTS
WORKBOOK
IMPORTANT SAFETY INSTRUCTIONS
The information contained in this technical guide is intended for Zodiac trained service personnel only.
Electrical installation and repairs should only be performed by a certified electrician or Zodiac trained
professional. and must comply with all national electric codes (NEC, Canadian, etc.). state and local law,
ordinances, codes and regulations.
If you have not received training, do not attempt any of the electrical repairs presented in this document.
Contact Zodiac Pool Stsyems, Inc. at 1-800-822-7933 for assistance.
Read and follow all instructions carefully.
When servicing equipment, basic safety precautions should always be followed including those listed
below.
!
WARNING
Failure to heed the following warnings could result in property
damage, permanent injury or death.
TO REDUCE THE RISK OF ELECTRICAL SHOCK:
• Disconnect main power to pool equipment area prior to any service or repairs.
• Keep all electrical equipment at least 10 feet (3m) from inside wall of pool or spa.
• Connect equipment only to a receptacle (cord models) or circuit (hardwired) protected by a
ground fault circuit interrupter (GFCI).
• Use only copper conductors and supply wires suitable for the specific device.
• Replace damaged power cord(s) immediately and use only identical replacement parts.
• Do not bury power cord(s). Position cord(s) to minimize abuse from lawn mowers, hedge
trimmers and other equipment.
• Do not install or service equipment if precipitation is present or imminent.
TO REDUCE EQUIPMENT WATER PRESSURE HAZARD:
• Always turn pump off to release pressure prior to removing or installing in-line equipment.
•To avoid equipment damage, do not exceed water pressure (psi) specifications for
the device.
To reduce the risk of injury, do not permit children to operate, handle or play on equipment.
3
Zodiac® Pool Systems, Inc.
1-800-822-7933
Regional Extension_________________
www.ZodiacPoolSystems.com
Zodiac Academy
zodiac.academy@zodiac.com
www.trainyu.com/zodiac
Instructor: __________________________________________________ ext. _______
Sales person: ________________________________________________ ext. _______
Service Manager: ____________________________________________ ext. _______
Notes:
4
TABLE
OFOFCONTENTS
TABLE
CONTENTS
Models and Features
6-7
Installation
8 - 17
Operation/Syncing
18 - 22
Troubleshooting and Repair
23 - 27
5
MODELS & FEATURES
Underwater Light Models
JPS Watercolors
White ONLY
(YELLOW)
Color and White Only
Jandy® Pro Series
(WHITE)
SAVI Emulation
(BLUE)
Intellibrite Emulation
(RED)
P-Series
(ORANGE)
H-Series
SAVI®
Color Only
S-Series
UCL Emulation
JPS SKU numbering system
JLU4C9W100
Jandy® LED
Usage*
• U = Underwater • A = Accessory
• O = Outdoor
• B = Bubbler
Color
• 4C = RGBW WaterColors (Multi-color)
• W = White only
Max Wattage
• 9 = 9W Max
• 20 = 20W Max
• 30 = 30W Max
6
Cord Length
• 50 = 50 feet
• 100 = 100 feet
• 150 = 150 feet
*Note: Accessory and Outdoor
usages not currently available
Bubblers
White Only Lights
Color Lights
Conversion
Guide
MODELS & FEATURES
DISCONTINUED AUGUST 1st,
2015
AVAILABLE AUGUST 1st, 2015
DISCONTINUED AUGUST 1st, 2015
First Generation
Nicheless Lights
New JPS Second Generation Nicheless
Lights
RGBW
SAVI J/S/P/H-SERIES
RGB
JLUC10-50
JLUC10-100
JLUC10-150
N/A
N/A
N/A
N/A
N/A
N/A
JLUW10-50
JLUW10-100
JLUW10-150
JLUW15-50
JLUW15-100
JLUW15-150
N/A
N/A
N/A
N/A
N/A
N/A
N/A
JLU4C9W50
Ja ndy LED Underwa ter Li ght,
JLU4C9W100
RGBW Wa tercol ors 9W
JLU4C9W150
JLU4C20W50
Ja ndy LED Underwa ter Li ght,
JLU4C20W100 RGBW Wa tercol ors 20W
JLU4C20W150
JLU4C30W50
Ja ndy LED Underwa ter Li ght,
JLU4C30W100 RGBW Wa tercol ors 30W
JLU4C30W150
JLUW9W50
Ja ndy LED Underwa ter Li ght,
JLUW9W100
Whi te Onl y 9W
JLUW9W150
JLUW20W50
Ja ndy LED Underwa ter Li ght,
JLUW20W100
Whi te Onl y 20W
JLUW20W150
JLUW30W50
Ja ndy LED Underwa ter Li ght,
JLUW30W100
Whi te Onl y 30W
JLUW30W150
JLB4C20W100 Ja ndy LED Li ghted Bubbl er,
JLB4C20W150 RGBW Wa tercol ors 20W
JLBW20W100 Ja ndy LED Li ghted Bubbl er,
Whi te Onl y 20W
JLBW20W150
MINI-MELODY50-J/S/P/H
MINI-MELODY100-J/S/P/H
MINI-MELODY150-J/S/P/H
SAVI-MELODY50-J/S/P/H
SAVI-MELODY100-J/S/P/H
SAVI-MELODY150-J/S/P/H
SAVI-SOL50-J/S/P/H
SAVI-SOL100-J/S/P/H
SAVI-SOL150-J/S/P/H
MINI-MB50
MINI-MB100
MINI-MB150
MB-50
MB-100
MB-150
MBPRO-50
MBPRO-100
MBPRO-150
BUB-XMEL100
BUB-XMEL150
BUB-XMB100
BUB-XMB150
AVAILABLE AUGUST 1st, 2015
S-SERIES
Blue Label
SAVMIN50S
SAVMIN100S
SAVMIN150S
SAVMEL50S
SAVMEL100S
SAVMEL150S
SAVSOL50S
SAVSOL100S
SAVSOL150S
New SAVI (RGBW)
P-SERIES
Red Label
SAVMIN50P
SAVMIN100P
SAVMIN150P
SAVMEL50P
SAVMEL100P
SAVMEL150P
SAVSOL50P
SAVSOL100P
SAVSOL150P
H-SERIES
Orange Label
SAVMIN50H
SAVMIN100H
SAVMIN150H
SAVMEL50H
SAVMEL100H
SAVMEL150H
SAVSOL50H
SAVSOL100H
SAVSOL150H
OnlY Available under JPS
OnlY Available under JPS
OnlY Available under JPS
SAVBUB100S
SAVBUB150S
SAVBUB100P
SAVBUB150P
SAVBUB100H
SAVBUB150H
OnlY Available under JPS
Features
UNDERWATER LIGHT FEATURES
•
•
•
•
•
•
•
•
4" Minimum Water Depth
Fits Standard 1-1/2" Wall Fittings
No Niche. No Grounding. No Bonding.
180° Beam for Complete Coverage
No Removal During Liner Changes
Flush Mounts
Accepts Designer Series Lenses
Field Interchangeable, Upgradeable &
Replaceable Cartridges.
7
INSTALLATION
-WARNINGThese underwater swimming pool lights MUST BE installed by a licensed or
certified electrician or a qualified pool professional in accordance with the
National Electric Code® (NEC®) or the Canadian Electric Code (CEC), CSA C22.1.
All applicable local installation codes and ordinances must also be adhered to.
Improper installation will create an electrical hazard which could result in death
or serious injury to pool users, installers or others due to electrical shock.
ALWAYS DISCONNECT THE POWER TO THE POOL LIGHT(S) BEFORE SERVICING.
-WARNINGBefore installing this product, read and follow all warning notices and
instructions in this Guide. Failure to follow warnings and instructions can result
in severe injury, death or property damage. For more information contact
company at numbers contained within Guide.
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
8
INSTALLATION
LED Light Installation
LED LIGHT INSTRUCTION INCLUDE ALL
THE FOLLOWING PRODUCTS:
JPS RGBW COLOR
JPS WHITE
SAVMIN RGBW COLOR
SAVMEL RGBW COLOR
SAVSOL RGBW COLOR
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
9
INSTALLATION
LED
Installation
JPS Light
COLOR
LIGHT INFO
•
•
•
•
•
•
•
•
Low Voltage
Uses UL listed Class 2 12VAC Transformer
Cords vary in length
Most lights are serviceable
No bonding required
No niche required
Replaceable light cartridge
Multiple lenses for different affects
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
10
INSTALLATION
JPS WHITE
INFO
JPS
COLORLIGHT
LIGHT
INFO
ITEM
JLU4C9W50
JLU4C9W100
UP TO A
MAXIMUM OF:
MINIMUM
PIPE LENGTH
9 WATTS
3"
20 WATTS
9"
30 WATTS
14"
JLU4C9W150
JLU4C20W50
JLU4C20W100
JLU4C20W150
JLU4C30W50
JLU4C30W100
JLU4C30W150
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
11
INSTALLATION
JPS WHITE LIGHT INFO
ITEM
UP TO A
MAXIMUM OF:
MINIMUM
PIPE LENGTH
JLUWC9W50
JLUWC9W100
JLUWC9W150
9 WATTS
3"
JLUWC20W50
JLUWC20W100
JLUWC20W150
20 WATTS
9"
30 WATTS
14"
JLU4W30W50
JLU4W30W100
JLU4W30W150
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
12
INSTALLATION
Preparing for Installation Diagram
12 VAC Class 2 Transformer
or
Junction Box
48" min.
Check AHJ for other j-box requirements
8“ minimum to maximum
water level
MAX POSSIBLE WATER LINE
(Top of copping)
4“ min to top of lens
Rigid 1” Rigid Electrical Conduit.
Sweep elbows only, no 90° elbows.
TYPICAL WATER LINE
(Mid Tile Line)
1.5” pipe through bond beam and a
minimum length for each style light.
(See Light Info charts)
NOTE: Vertical installations such as bench and walk-out locations will use ALL of the same clearance requirements.
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
13
Preparing for Installation Diagram
INSTALLATION
NEC 680.26(B)(4)
Low-voltage lighting systems with
nonmetallic forming shells shall not
require bonding.
Rigid 1” electrical conduit
4“ min to top of lens
1.5” pipe through bond beam
(See chart for required lengths)
1.5” Female
Threaded Wall Fitting
Note: Use rubber gaskets as appropriate for
Redundant Seal Technology. Gaskets help
ensure conduit is not a potential leak path.
Lens Key
14
Using the supplied Lens Key, thread the light into the wall fitting until it is snug. It is
recommended to supply the home owner with at least 1 key upon job completion
INSTALLATION
CAUTION
Jandy® Pro Series Nicheless Underwater LED Lights are low voltage fixtures. Improper wire
gauge or wire length can effect the performance of these products. Refer to your Owner's
Manual for complete sizing details.
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which could result in serious injury or
death. A Ground Fault Circuit Interrupter (GFCI) must be provided for 120 Volt
transformers. The conductors on the load side of the GFCI circuit shall not occupy conduit,
boxes, or enclosures containing other conductors unless the additional conductors are also
protected by a GFCI. Refer to local codes for complete details.
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which could result in serious injury or
death. The Jandy Pro Series Nicheless LED Lights are only available for 12-volt AC power.
For supply connection, use only an isolating low voltage power supply with ungrounded
output, evaluated and listed by a NRTL for swimming pool use.
IMPORTANT NOTE:
All fixtures must be tied into the same transformer, circuit or switch for synchronization to occur. The use of Solid
Core over Stranded wire and terminating Bus Bars is strongly recommended.
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
15
INSTALLATION
Wiring to an switch/timeclock
The Jandy® Pro Series Nicheless LED Lights can be wired to a switch
to manually operate the lights.
16
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
INSTALLATION
Wiring to an AquaLink® controller
To ensure maximum safety, use only a Class 2 transformer that can supply 12-14
Volts AC to power all 12-Volt lights. The transformer must be listed or certified by
a Nationally Recognized Testing Laboratory (NRTL) for the intended use.
NEC ® 680.23(A)(2)
Transformers and power supplies are required to be
specifically listed for swimming pool use. Unless marked
otherwise, swimming pool and spa transformers are not
suitable for connection to a conduit that extends directly
to an underwater pool light forming shell. Swimming
pool and spa transformers are not permitted to be used
outdoors unless marked "For Outdoor Use" or in an
equivalent manner that signifies that they have been
found acceptable for outdoor use. NEC 110.3(B) defines
the requirements on the installation and use of listed
electrical equipment.
Jandy®Pro Series color lights are NOT DIMMABLE and are NOT COMPATIBLE with dimmer switches or dimmer relays.
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
17
OPERATION
OPERATION
LIGHT SYNCHRONIZATION (RGBW series lights)
1. Turn ON the light(s) (Light will display previously selected color).
2. Reset the light(s).
• Turn the lights OFF for 5 seconds
• Turn the lights back on (ALL the lights should return to
Alpine White, otherwise repeat).
3. To select a color mode, turn the lights OFF for 1 to 3 seconds then
back ON. Repeat this sequence until desired color is reached.
4. The lights have an internal memory and if left on for more then 7
seconds will retain the select color.
NOTE:
All fixtures must be tied into the same transformer,
circuit or switch for synchronization to occur.
LIGHT SYNCHRONIZATION with RS Rev. T
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
18
SYNCING
COLOR MODE SEQUENCE
Color Mode
NOTE
To synchronize colors on multiple Jandy® Pro Series Nicheless
Underwater LED Light systems wired to separate switches,
perform the above actions on all of their switches
simultaneously. All Jandy Pro Series Nicheless Underwater
LED Lights will synchronize automatically if activated by the
same switch. No other accessories are required.
1
Alpine White
2
Sky Blue
3
Cobalt Blue
4
Caribbean Blue
5
Spring Green
6
Emerald Green
7
Emerald Rose
8
Magenta
9
Violet
10
Slow Color Splash
11
Fast Color Splash
12
America the Beautiful
13
Fat Tuesday
14
Disco Tech
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
19
SYNCING
LED Syncing Setup
With the RS Revision T or newer, any Jandy LED will
automatically synchronize the shows if there are lights
installed on different transformers , assigned to different
Auxiliary’s, and are setup as “JL” in the system setup.
LED Syncing
Turn on one of the lights the any of the shows.
NOTE:
At anytime you can change the color or show of any one light Auxiliary by
selecting the Aux you want to change and selecting a different color or show.
20
SYNCING
LED Syncing
Turn on the next light and select the same show.
During the light sync all
selected lights are reset and
automatically turned off
and on until the chosen
show is selected.
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
21
SYNCING
LED Syncing
Repeat as needed. (ie: fountains, extra zones, separate spa etc…)
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
22
TROUBLESHOOTING
In-field Light Identification
Dot Color Indicates
RGBW Series
= Jandy® Pro Series (JPS)
(YELLOW)
= SAVI (S–Series)
(BLUE)
= SAVI (H–Series)
(ORANGE)
= SAVI (P–Series)
(RED)
No dot indicates the light is JPS white series
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
23
TROUBLESHOOTING
Troubleshooting Guide
Symptom
All lights fail to illuminate
One or more lights are
dim, blinking or not
working
Colored lights out of synch
Possible Cause
Solution
Lights are not receiving
power
Check 120VAC power supply into
transformer. Check for 12VAC output
at transformer. Check or reset GFCI.
Make sure 120 volts has not been
used in the installation - damage is
assured and is NON WARRANTY.
Poor connection or
improper wire gauge
Improper voltage supply or
poor connection to the light
Separate each light and independently
wire 12V to the single light only.
Repeat this process on each light. If
junction box is being used, check for
proper connection of light cord. Verify
that the correct wire gauge is being
used between the transformer and
junction box.
Verify that proper wire connections
are being achieved for the lights that
are out of synch. Reset all the lights to
white by turning lights OFF for five (5)
seconds, then turning ON
32
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
24
T/S and Repair
Troubleshooting, Wiring
Confirm Proper Voltage
& Wire Gauge.
Check for proper
secondary voltage.
Confirm the
secondary is 12 to 14
VAC. (Check the wiring
label on the transformer
to confirm expected
secondary voltage).
Confirm Wires are stripped back
completely and all connections are
solid & tight. Check for corrosion.
Note: If a junction box is used after the transformer, the voltage should be checked at that location also.
NOTES:
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
25
T/S and Repair
Light Cartridge Replacement
Light Cartridge Replacement
1. Remove the eight screws from the lens using a T8 Torx driver
or the torques tool provided. Pull off the lens, remove and
discard the o-ring.
2. Using the extraction tool , thread into the extraction hole in
the face of the light cartridge and gentle pull to remove the
cartridge from the housing body.
3. Insert the replacement cartridge to the
housing. Align the end circuit board tab the
receiving slot and press into place.
Extraction tool
Be sure to do repairs in a dry area. ie: Drain the water below the light or pull the light to deck. Do not attempt repairs in the pool/spa.
Light Cartridge Replacement
4. Clean the leans and reapply silicon to
the outer edge of the lens along the
screw holes.
5. Press the lens into place, then tighten
the screws in the shown wagon
wheel pattern.
2
8
3
5
6
4
7
1
6. Reset the fixture into the wall
fitting and restore power.
26
Before securing to the wall fitting, slowly submerse in water, checking for any air bubbles - quickly remove from
water if bubbles appear as it indicates the seal is not water tight, retighten the screws and test for bubbles again.
T/S and Repair
Light Cartridge Inspection
Signs when the light has been accidentally hooked up to high voltage or if there has
been a large power surge or lightning strike.
New/Good
Damaged
Winterization
• The water level should be lowered to
approximately 12 inches below the pool
lights.
• Make certain that the water is drained
out of the wall housing. Consult a Local
Swimming Pool Professional for proper
winterization.
• Minimum safeguard requires dropping
the water level 2”-4” below the light.
• At NO TIME should there be water
removed from the pool without checking
ground water tables.
27
Download