!!! DANGER !!! WARNING !!!

advertisement
Installation / Operation Instruction
Model KA-1801 / 1803 / 1804 / 1805 / 1806
Light Fittings
!!! DANGER !!! WARNING !!!
Use A LICENSED ELECTRICIAN AND CHECK WITH LOCAL AND
NATIONAL CODES
Inspection glass lamps for areas where there is no risk of explosion.
The lamp housing and its attachments can be hot!
Caution! Do not touch!
Keep away from flammable substances!
The bulb can be hot!
Caution! Do not touch!
Keep away from flammable substances!
The sight glass and its attachments can be hot!
Caution! Do not touch!
Keep away from flammable substances!
Lamp components are live!
Caution! Electric shock!
Disconnect lamp from power supply prior to disassembly!
1. Assembly instruction
Attention! Take note of the correct connection voltage. The connection voltages
depend on the capacity of the bulb used and vice versa (see Table 1).
The lamp may only be operated in a manner that ensures that the temperature of the
lamp housing does not exceed 110°F!
2. Maintenance instructions
2.1 Replacing the bulb
Installation / Operation Instruction
Model KA-1801 / 1803 / 1804 / 1805 / 1806
Light Fittings
Ensure that the lamp and the components connected to it, e.g. the inspection glass,
are not hot.
o Unscrew the connection (1) between the cable plug on the lamp and the cable
socket on the connecting cable.
o Disconnect the cable socket from the cable plug.
o Unscrew the base of the lamp (2) by hand. If the base cannot be unscrewed
by hand, use a belt tension wrench to fix the top and base and then loosen.
o Remove old bulb and insert new bulb in the lamp holder.
Attention! Only use bulbs with the appropriate voltage and capacity for the
lamp (see Table 1).
Attention! Do not touch the bulb directly.
o Coat the o-ring of the lamp base with food-grade grease. Screw the base of
the lamp to the top by hand.
o Connect cable plug with the lamp socket and screw both together.
2.2 Changing the lamp o-ring seal
Ensure that the lamp and the components connected to it, e.g. the inspection glass,
are not hot.
o Unscrew the connection (1) between the cable plug on the lamp and the cable
socket on the connecting cable.
o Disconnect the cable socket from the cable plug.
o Unscrew the base of the lamp (2) by hand. If the base cannot be unscrewed
by hand, use a belt tension wrench to fix the top and base and then loosen.
o Remove old o-ring (3) and fit a new one.
Attention! Only use original spare parts!
o Coat the o-ring of the lamp base with food-grade fat. Screw the base of the
lamp to the top by hand.
o Connect cable plug with the lamp socket and screw both together.
Installation / Operation Instruction
Model KA-1801 / 1803 / 1804 / 1805 / 1806
Light Fittings
3. Technical data
Type
Capacity at 12 V
Capacity at 24 V
5W
10W
20W
1805
x
x
x
Table 1: Bulb capacity as a function of
the connection voltage and the lamp
type
Fig. 2: Boring template for type 1806
Fig. 1: Lamp circuit diagram with 3-pin
connection cable used (type 18041806).
Fig.
3: Lamp spare parts
Fig. 4: Lamp circuit diagram with 3-pin
connection cable used (type 1803).
Typ
Cable
Cable
1
2
1805
Brown
Black
Table 2: Colours of the connection cable
Pos.
Description
P/N.
4
Bulb 20 W-24V
410 001
3
Sealing
230 006
Table 3: Spare Parts