" STAINLESS STEEL SCREWS (4 REQUIRED) 7" MIN. HAND HOLE COVER NEOPRENE GASKET SIGNAL HEAD TERMINAL MAST ARM 2’-0" MIN. TO 2’-6" MAX. BLOCK OR APPROVED EQUIVALENT FRONT VIEW GROUNDING LUG 1 0" CASTINGS, INC. SIDE VIEW BLOCK MIN. ENGINEERED TERMINAL TUNNEL 1 ’-6" VISOR TOP VIEW SIGNAL HEAD BRACKET TYPICAL HANDHOLE AND TERMINAL COMPARTMENT DETAILS ATTACHMENT DETAIL NOT TO SCALE NOT TO SCALE REVISIONS DATE BY DESCRIPTION DATE Collier County Traffic Operations BY DESCRIPTION 2885 South Horseshoe Drive Naples, Florida 34104 Phone: (239) 774-8192 Fax: (239) 213-5868 SHEET COLLIER COUNTY GROWTH MANAGEMENT DIVISION MAST ARM DETAILS NO. TSP-15 NOTE: CONDUIT REQUIREMENTS FOR A 1-WAY MAST ARM INSTALLATION. REFER TO CONSTRUCTION NOTES FOR CONDUIT REQUIREMENTS FOR A 2-WAY MAST ARM INSTALLATION. CONSTRUCTION NOTES: PULL BOX NUMBER 3 PULL BOX NUMBER 2 PULL BOX NUMBER 1 (TYPE "B") (TYPE "B") (TYPE "B") 1. PULL BOX NUMBER 1 (TYPE "B") SHALL CONTAIN CABLES FOR VEHICLE SIGNAL INDICATIONS, PEDESTRIAN SIGNAL 6" APRON 12" APRON 6" APRON INDICATIONS, STREET LIGHTING, AND ILLUMINATED SIGNAGE, 12" APRON AS NEEDED. FINAL GRADE 2. PULL BOX NUMBER 2 (TYPE "B") SHALL CONTAIN CABLES FOR VEHICLE VIDEO DETECTION, EMERGENCY VEHICLE DETECTION, AND ITS CCTV CAMERA, AS NEEDED. 3. PULL BOX NUMBER 3 (TYPE "B") SHALL CONTAIN CABLES FOR PEDESTRIAN DETECTION AS NEEDED. 4. A 2-WAY MAST ARM INSTALLATION SHALL REQUIRE 1 ADDITIONAL 2" CONDUIT IN PULL BOX NUMBER 1. 3. GROUND WIRE SHALL BE #6 STRANDED. 4. ALL SEPERATELY GROUNDED ELEMENTS AT AN INTERSECTION SHALL BE BONDED TOGETHER TO FORM AN INTERSECTION 20 LF 3" PVC SCHEDULE 40 CONDUIT (30" DEPTH). INCH GROUNDING NETWORK. 2" PVC SCHEDULE DIAMETER COPPER 40 CONDUIT CLAD GROUND ROD (30" DEPTH). CONTINUOUS OR ARRAY. TYPICAL MAST ARM PULL BOX AND CONDUIT DETAIL NOT TO SCALE REVISIONS DATE BY DESCRIPTION DATE Collier County Traffic Operations BY DESCRIPTION 2885 South Horseshoe Drive Naples, Florida 34104 Phone: (239) 774-8192 Fax: (239) 213-5868 SHEET COLLIER COUNTY GROWTH MANAGEMENT DIVISION MAST ARM DETAILS NO. TSP-16 TWO NO. 8 AWG CONDUCTORS TO ROADWAY LUMINAIRE MAST ARM IF REQUIRED, SEE PLANS VEHICLE LEFT TURN TRAFFIC SIGNAL INDICATIONS VEHICLE THROUGH TRAFFIC SIGNAL INDICATIONS VEHICLE THROUGH IMSA 19-1 9 CONDUCTOR IMSA 19-1 7 CONDUCTOR CABLE TO VEHICLE LEFT HANDHOLE TRAFFIC SIGNAL INDICATIONS VEHICLE RIGHT TURN CABLE TO VEHICLE TURN TRAFFIC SIGNAL INDICATIONS IF ROADWAY TRAFFIC SIGNAL INDICATIONS THROUGH TRAFFIC LUMINAIRE IMSA 19-1 7 CONDUCTOR SIGNAL INDICATIONS STREET NAME SIGN IS REQUIRED CABLE TO VEHICLE LOAD SIDE THROUGH TRAFFIC IMSA 19-1 9 CONDUCTOR 5 CONDUCTOR CABLE SIGNAL INDICATIONS CABLE TO VEHICLE RIGHT TO ILLUMINATED TURN TRAFFIC SIGNAL STREET NAME SIGN RED INDICATIONS ORANGE GREEN IMSA 19-1 7 CONDUCTOR GENERAL NOTES CABLE FROM VEHICLE WHITE (NEUTRAL) THROUGH INDICATIONS (SPARES) LINE SIDE 3 RED ORANGE 4 GREEN GREEN BUS BAR. 3. ALL ELECTRICAL CONNECTIONS IN THE SIGNAL POLE BASE, CONTROLLER IMSA 19-1 7 CONDUCTOR CABLE FROM VEHICLE 2 WHITE (NEUTRAL) WHITE (NEUTRAL) SIGNAL POLE 2. TERMINATE SPARE CONDUCTORS IN CONTROLLER ASSEMBLY TO GROUND RED 5 ORANGE 1. INDIVIDUALLY CAP SPARES CONDUCTORS IN SIGNAL HEAD. CABINET AND SIGNAL HEADS SHALL BE MADE WITH "BURNDY HYLUG" OR APPROVED EQUAL. THROUGH INDICATIONS 4. LUMINAIRE ELECTRICAL CONDUCTORS TO BE INSTALLED IN TRAFFIC SIGNAL 1 BLACK (SPARE) POLES AND FROM THE CONTROLLER TO EACH TRAFFIC SIGNAL POLE, SHALL (SPARES) BE STRANDED COPPER TYPE THHN OR THWN 600 VOLT. AN ALTERNATE 8 RED/BLACK RED 10 ORANGE/BLACK ORANGE 9 GREEN/BLACK GREEN 7 WHITE/BLACK WHITE (NEUTRAL) TYPE OF INSULATION MAY BE USED IF APPROVED BY THE RESIDENT ENGINEER PRIOR TO INSTALLATION. IMSA 19-1 15 CONDUCTOR CABLE IMSA 19-1 9 CONDUCTOR CABLE FROM VEHICLE MINIMUM TO CONTROLLER RIGHT TURN INDICATIONS A NUMBER 6 AWG STRANDED COPPER WIRE SHALL BE CONNECTED FROM THE GROUND ROD TO THE GROUNDING LUG AT THE BASE OF THE POLE. ASSEMBLY 6 BLUE (SPARE) 5. EACH TRAFFIC SIGNAL POLE SHALL BE GROUNDED TO A GROUND ROD. ALL SEPERATELY GROUNDED ELEMENTS AT AN INTERSECTION SHALL BE (SPARES) BONDED TOGETHER TO FORM AN INTERSECTION GROUNDING NETWORK. 13 RED/WHITE RED 15 BLUE/WHITE ORANGE PEDESTRIAN 6. EACH TURNING MOVEMENT SIGNAL HEAD SHALL HAVE A NINE CONDUCTOR 14 GREEN/WHITE GREEN SIGNAL CABLE. EACH THROUGH MOVEMENT SIGNAL INDICATION SHALL IMSA 19-1 9 CONDUCTOR CABLE FROM VEHICLE 12 BLACK/WHITE WHITE (NEUTRAL) LEFT TURN INDICATIONS SIGNAL INDICATION PEDESTRIAN HAVE A SEVEN CONDUCTOR CABLE. EACH PEDESTRIAN MOVEMENT SIGNAL SIGNAL INDICATION SHALL HAVE A FIVE CONDUCTOR CABLE. EACH PEDESTRIAN INDICATION BUTTON SHALL HAVE A TWO CONDUCTOR SHIELDED CABLE. EACH ILLUMINATED L.E.D. STREET NAME SIGN SHALL HAVE A FIVE CONDUCTOR 11 BLUE/BLACK (SPARE) (SPARES) CABLE. 1 BLACK (SPARE) RED (DON’T WALK) RED TRAFFIC SIGNAL ELECTRIC CABLE SEQUENCE GREEN (WALK) RED (DON’T WALK) 1 ASSEMBLY 9 GREEN/BLACK GREEN (WALK) IMSA 19-1 5 CONDUCTOR CABLE 7 WHITE/BLACK (NEUTRAL) WHITE (NEUTRAL) WHITE 3 RED 4 GREEN 5 ORANGE 6 BLUE 7 WHITE/BLACK 8 RED/BLACK 9 GREEN/BLACK BLACK BLACK IMSA 19-1 5 CONDUCTOR CABLE 2 WHITE (NEUTRAL) WHITE (NEUTRAL) TO CONTROLLER ASSEMBLY RED (SPARE) WHITE (NEUTRAL) WHITE (NEUTRAL) BLACK BLACK 1/C NO. 10 AWG FROM LUMINAIRE NO.8 AWG TO CONTROLLER ASSEMBLY 5 CONDUCTOR CABLE TO CABLE TO PEDESTRIAN PEDESTRIAN SIGNAL SIGNAL INDICATION INDICATION IMSA 50-2 SHIELDED IMSA 19-1 5 CONDUCTOR CABLE FROM ILLUMINATED SIGN PANEL RED (SPARE) 5 CONDUCTOR FROM PEDESTRIAN INDICATION (SPARES) 6 BLUE (SPARE) BLACK 21C (SPARES) 8 RED/BLACK 15C 5 ORANGE (SPARE) MINIMUM TO CONTROLLER BASE / TRACER COLOR 18C 9 CONDUCTOR CABLE CONDUCTOR NUMBER 9C FROM PEDESTRIAN INDICATION 5C WHITE (NEUTRAL 2C 2 WHITE (NEUTRAL) IMSA 19-1 12C CABLE SIZE IMSA 19-1 5 CONDUCTOR CABLE 7C 3 4 GREEN 10 ORANGE/BLACK 11 BLUE/BLACK 12 BLACK/WHITE 13 RED/WHITE 14 GREEN/WHITE 15 BLUE/WHITE 16 BLACK/RED 17 WHITE/RED 18 ORANGE/RED 19 BLUE/RED 20 RED/GREEN 21 ORANGE/GREEN CABLE TO PUSH BUTTONS 1/C NO. 10 AWG FROM LUMINAIRE NO.8 AWG TO CONTROLLER ASSEMBLY SEE "TERMINAL STRIP DETAIL" TO EARTH GROUND BOND TO SIGNAL POLE GROUND LUG BLACK WHITE (NEUTRAL) CONTINUOUS FROM CONTROLLER ASSEMBLY TO PEDESTRIAN PUSH BUTTON IMSA 50-2 SHIELDED CABLE IMSA 50-2 SHIELDED CABLE TO CONTROLLER ASSEMBLY FROM PEDESTRIAN PUSH BUTTON SHEILD WHITE (NEUTRAL) BLACK WHITE (NEUTRAL) SHEILD IMSA 50-2 SHIELDED CABLE IMSA 50-2 SHIELDED CABLE TO CONTROLLER ASSEMBLY FROM PEDESTRIAN PUSH BUTTON BLACK HANDHOLE THIS SHEET " GROUNDING LUG WHITE (NEUTRAL) BLACK SIGNAL POLE WIRING TERMINAL STRIP DETAIL NOT TO SCALE TYPICAL MAST ARM WIRING DETAIL NOT TO SCALE NOT TO SCALE REVISIONS DATE BY DESCRIPTION DATE Collier County Traffic Operations BY DESCRIPTION 2885 South Horseshoe Drive Naples, Florida 34104 Phone: (239) 774-8192 Fax: (239) 213-5868 SHEET COLLIER COUNTY GROWTH MANAGEMENT DIVISION MAST ARM DETAILS NO. TSP-17