" STAINLESS STEEL SCREWS
(4 REQUIRED)
7"
MIN.
HAND HOLE COVER
NEOPRENE GASKET
SIGNAL
HEAD
TERMINAL
MAST ARM
2’-0" MIN. TO 2’-6" MAX.
BLOCK
OR APPROVED
EQUIVALENT
FRONT VIEW
GROUNDING LUG
1
0"
CASTINGS, INC.
SIDE VIEW
BLOCK
MIN.
ENGINEERED
TERMINAL
TUNNEL
1
’-6"
VISOR
TOP VIEW
SIGNAL HEAD BRACKET
TYPICAL HANDHOLE AND
TERMINAL COMPARTMENT DETAILS
ATTACHMENT DETAIL
NOT TO SCALE
NOT TO SCALE
REVISIONS
DATE
BY
DESCRIPTION
DATE
Collier County Traffic Operations
BY
DESCRIPTION
2885 South Horseshoe Drive
Naples, Florida 34104
Phone: (239) 774-8192
Fax: (239) 213-5868
SHEET
COLLIER COUNTY
GROWTH MANAGEMENT DIVISION
MAST ARM
DETAILS
NO.
TSP-15
NOTE:
CONDUIT REQUIREMENTS FOR A 1-WAY MAST
ARM INSTALLATION. REFER TO CONSTRUCTION
NOTES FOR CONDUIT REQUIREMENTS FOR
A 2-WAY MAST ARM INSTALLATION.
CONSTRUCTION NOTES:
PULL BOX NUMBER 3
PULL BOX NUMBER 2
PULL BOX NUMBER 1
(TYPE "B")
(TYPE "B")
(TYPE "B")
1. PULL BOX NUMBER 1 (TYPE "B") SHALL CONTAIN CABLES
FOR VEHICLE SIGNAL INDICATIONS, PEDESTRIAN SIGNAL
6" APRON
12" APRON
6" APRON
INDICATIONS, STREET LIGHTING, AND ILLUMINATED SIGNAGE,
12" APRON
AS NEEDED.
FINAL GRADE
2. PULL BOX NUMBER 2 (TYPE "B") SHALL CONTAIN CABLES
FOR VEHICLE VIDEO DETECTION, EMERGENCY VEHICLE
DETECTION, AND ITS CCTV CAMERA, AS NEEDED.
3. PULL BOX NUMBER 3 (TYPE "B") SHALL CONTAIN CABLES
FOR PEDESTRIAN DETECTION AS NEEDED.
4. A 2-WAY MAST ARM INSTALLATION SHALL REQUIRE 1
ADDITIONAL 2" CONDUIT IN PULL BOX NUMBER 1.
3. GROUND WIRE SHALL BE #6 STRANDED.
4. ALL SEPERATELY GROUNDED ELEMENTS AT AN INTERSECTION
SHALL BE BONDED TOGETHER TO FORM AN INTERSECTION
20 LF
3" PVC SCHEDULE
40 CONDUIT
(30" DEPTH).
INCH
GROUNDING NETWORK.
2" PVC SCHEDULE
DIAMETER COPPER
40 CONDUIT
CLAD GROUND ROD
(30" DEPTH).
CONTINUOUS OR
ARRAY.
TYPICAL MAST ARM
PULL BOX AND CONDUIT DETAIL
NOT TO SCALE
REVISIONS
DATE
BY
DESCRIPTION
DATE
Collier County Traffic Operations
BY
DESCRIPTION
2885 South Horseshoe Drive
Naples, Florida 34104
Phone: (239) 774-8192
Fax: (239) 213-5868
SHEET
COLLIER COUNTY
GROWTH MANAGEMENT DIVISION
MAST ARM
DETAILS
NO.
TSP-16
TWO NO. 8 AWG CONDUCTORS
TO ROADWAY LUMINAIRE
MAST ARM
IF REQUIRED, SEE PLANS
VEHICLE LEFT TURN
TRAFFIC SIGNAL INDICATIONS
VEHICLE THROUGH
TRAFFIC SIGNAL INDICATIONS
VEHICLE THROUGH
IMSA 19-1 9 CONDUCTOR
IMSA 19-1 7 CONDUCTOR
CABLE TO VEHICLE LEFT
HANDHOLE
TRAFFIC SIGNAL INDICATIONS
VEHICLE RIGHT TURN
CABLE TO VEHICLE
TURN TRAFFIC SIGNAL
INDICATIONS
IF ROADWAY
TRAFFIC SIGNAL INDICATIONS
THROUGH TRAFFIC
LUMINAIRE
IMSA 19-1 7 CONDUCTOR
SIGNAL INDICATIONS
STREET NAME SIGN
IS REQUIRED
CABLE TO VEHICLE
LOAD SIDE
THROUGH TRAFFIC
IMSA 19-1 9 CONDUCTOR
5 CONDUCTOR CABLE
SIGNAL INDICATIONS
CABLE TO VEHICLE RIGHT
TO ILLUMINATED
TURN TRAFFIC SIGNAL
STREET NAME SIGN
RED
INDICATIONS
ORANGE
GREEN
IMSA 19-1 7 CONDUCTOR
GENERAL NOTES
CABLE FROM VEHICLE
WHITE (NEUTRAL)
THROUGH INDICATIONS
(SPARES)
LINE SIDE
3
RED
ORANGE
4 GREEN
GREEN
BUS BAR.
3. ALL ELECTRICAL CONNECTIONS IN THE SIGNAL POLE BASE, CONTROLLER
IMSA 19-1 7 CONDUCTOR
CABLE FROM VEHICLE
2 WHITE (NEUTRAL)
WHITE (NEUTRAL)
SIGNAL POLE
2. TERMINATE SPARE CONDUCTORS IN CONTROLLER ASSEMBLY TO GROUND
RED
5 ORANGE
1. INDIVIDUALLY CAP SPARES CONDUCTORS IN SIGNAL HEAD.
CABINET AND SIGNAL HEADS SHALL BE MADE WITH "BURNDY HYLUG" OR
APPROVED EQUAL.
THROUGH INDICATIONS
4. LUMINAIRE ELECTRICAL CONDUCTORS TO BE INSTALLED IN TRAFFIC SIGNAL
1 BLACK (SPARE)
POLES AND FROM THE CONTROLLER TO EACH TRAFFIC SIGNAL POLE, SHALL
(SPARES)
BE STRANDED COPPER TYPE THHN OR THWN 600 VOLT. AN ALTERNATE
8 RED/BLACK
RED
10 ORANGE/BLACK
ORANGE
9 GREEN/BLACK
GREEN
7 WHITE/BLACK
WHITE (NEUTRAL)
TYPE OF INSULATION MAY BE USED IF APPROVED BY THE RESIDENT
ENGINEER PRIOR TO INSTALLATION.
IMSA 19-1
15 CONDUCTOR CABLE
IMSA 19-1 9 CONDUCTOR
CABLE FROM VEHICLE
MINIMUM
TO CONTROLLER
RIGHT TURN INDICATIONS
A NUMBER 6 AWG STRANDED COPPER WIRE SHALL BE CONNECTED FROM
THE GROUND ROD TO THE GROUNDING LUG AT THE BASE OF THE POLE.
ASSEMBLY
6 BLUE (SPARE)
5. EACH TRAFFIC SIGNAL POLE SHALL BE GROUNDED TO A GROUND ROD.
ALL SEPERATELY GROUNDED ELEMENTS AT AN INTERSECTION SHALL BE
(SPARES)
BONDED TOGETHER TO FORM AN INTERSECTION GROUNDING NETWORK.
13 RED/WHITE
RED
15 BLUE/WHITE
ORANGE
PEDESTRIAN
6. EACH TURNING MOVEMENT SIGNAL HEAD SHALL HAVE A NINE CONDUCTOR
14 GREEN/WHITE
GREEN
SIGNAL CABLE. EACH THROUGH MOVEMENT SIGNAL INDICATION SHALL
IMSA 19-1 9 CONDUCTOR
CABLE FROM VEHICLE
12 BLACK/WHITE
WHITE (NEUTRAL)
LEFT TURN INDICATIONS
SIGNAL
INDICATION
PEDESTRIAN
HAVE A SEVEN CONDUCTOR CABLE. EACH PEDESTRIAN MOVEMENT SIGNAL
SIGNAL
INDICATION SHALL HAVE A FIVE CONDUCTOR CABLE. EACH PEDESTRIAN
INDICATION
BUTTON SHALL HAVE A TWO CONDUCTOR SHIELDED CABLE. EACH
ILLUMINATED L.E.D. STREET NAME SIGN SHALL HAVE A FIVE CONDUCTOR
11 BLUE/BLACK (SPARE)
(SPARES)
CABLE.
1 BLACK (SPARE)
RED (DON’T WALK)
RED
TRAFFIC SIGNAL ELECTRIC CABLE SEQUENCE
GREEN (WALK)
RED (DON’T WALK)
1
ASSEMBLY
9 GREEN/BLACK
GREEN (WALK)
IMSA 19-1 5 CONDUCTOR CABLE
7 WHITE/BLACK (NEUTRAL)
WHITE (NEUTRAL)
WHITE
3
RED
4
GREEN
5
ORANGE
6
BLUE
7
WHITE/BLACK
8
RED/BLACK
9
GREEN/BLACK
BLACK
BLACK
IMSA 19-1 5 CONDUCTOR CABLE
2
WHITE (NEUTRAL)
WHITE (NEUTRAL)
TO CONTROLLER ASSEMBLY
RED (SPARE)
WHITE (NEUTRAL)
WHITE (NEUTRAL)
BLACK
BLACK
1/C NO. 10 AWG FROM LUMINAIRE
NO.8 AWG TO CONTROLLER ASSEMBLY
5 CONDUCTOR
CABLE TO
CABLE TO
PEDESTRIAN
PEDESTRIAN
SIGNAL
SIGNAL
INDICATION
INDICATION
IMSA 50-2 SHIELDED
IMSA 19-1 5 CONDUCTOR CABLE
FROM ILLUMINATED SIGN PANEL
RED (SPARE)
5 CONDUCTOR
FROM PEDESTRIAN INDICATION
(SPARES)
6 BLUE (SPARE)
BLACK
21C
(SPARES)
8 RED/BLACK
15C
5 ORANGE (SPARE)
MINIMUM
TO CONTROLLER
BASE / TRACER
COLOR
18C
9 CONDUCTOR CABLE
CONDUCTOR
NUMBER
9C
FROM PEDESTRIAN INDICATION
5C
WHITE (NEUTRAL
2C
2 WHITE (NEUTRAL)
IMSA 19-1
12C
CABLE SIZE
IMSA 19-1 5 CONDUCTOR CABLE
7C
3
4 GREEN
10
ORANGE/BLACK
11
BLUE/BLACK
12
BLACK/WHITE
13
RED/WHITE
14
GREEN/WHITE
15
BLUE/WHITE
16
BLACK/RED
17
WHITE/RED
18
ORANGE/RED
19
BLUE/RED
20
RED/GREEN
21
ORANGE/GREEN
CABLE TO PUSH BUTTONS
1/C NO. 10 AWG FROM LUMINAIRE
NO.8 AWG TO CONTROLLER ASSEMBLY
SEE "TERMINAL
STRIP DETAIL"
TO EARTH GROUND
BOND TO SIGNAL POLE GROUND LUG
BLACK
WHITE (NEUTRAL)
CONTINUOUS FROM CONTROLLER ASSEMBLY TO PEDESTRIAN PUSH BUTTON
IMSA 50-2 SHIELDED CABLE
IMSA 50-2 SHIELDED CABLE
TO CONTROLLER ASSEMBLY
FROM PEDESTRIAN PUSH BUTTON
SHEILD
WHITE (NEUTRAL)
BLACK
WHITE (NEUTRAL)
SHEILD
IMSA 50-2 SHIELDED CABLE
IMSA 50-2 SHIELDED CABLE
TO CONTROLLER ASSEMBLY
FROM PEDESTRIAN PUSH BUTTON
BLACK
HANDHOLE
THIS SHEET
" GROUNDING LUG
WHITE (NEUTRAL)
BLACK
SIGNAL POLE
WIRING
TERMINAL STRIP
DETAIL
NOT TO SCALE
TYPICAL MAST ARM WIRING DETAIL
NOT TO SCALE
NOT TO SCALE
REVISIONS
DATE
BY
DESCRIPTION
DATE
Collier County Traffic Operations
BY
DESCRIPTION
2885 South Horseshoe Drive
Naples, Florida 34104
Phone: (239) 774-8192
Fax: (239) 213-5868
SHEET
COLLIER COUNTY
GROWTH MANAGEMENT DIVISION
MAST ARM
DETAILS
NO.
TSP-17