Dimensional Details Fleet Wall Hung Boilers Boiler General Dimensions and Clearance 150 540 540 150 Gland holes 21mm dia. x 2 Electric - 490 D 45 B 35 20 900 min. clearance C (Flue dia.) 560 crs 134 Return - 120 Safety valve - 195 Plan View Flow - 270 Condense - 345 Gas - 470 View on Underside 134 Note… Terminals can be cut to length (from elbow connection end) to suit the application. 300 min. 15 50 40 540 440 410 50 B When shortening terminals or terminal extensions, the outer section only should be cut first. This will allow access to the inner section, which, for a correct fit into the next concentric pipe fitting, must be cut so that it is 10 cm longer than the outer section. 8 holes 12 dia. 930 Wall mounting plate Plate centreline notched Boiler outline shown hatched Wall Mounting Arrangment 540 A Front View Side Flue Exit Side View Rear Flue Exit All dimensions in mm Dimensions (mm) Reference Model F40W F50W F60W F70W F85W F100W F125W F150W Casing depth A 470 570 Flue depth B 380 480 Flue diameter C 80/125 100/150 Electrical connections D 350 450 9 Dimensional Details Fleet Wall Hung Boiler Pipe Kits & Flue Headers Low Loss Headers Single Boiler Arrangement A.A.V. 180 Nom. Secondary return 190 Nom. 380 Nom. Primary flow Primary return 560 Nom Secondary flow 665 Nom. 30 540 300 Min 147 150 760 Nom. 165 O/D Pocket for temperature sensors x 2 507 A.A.V. Internal transfer pipe 1500 Nom. 1405 Nom. 560 Nom. 370 Nom. 180 Nom. 380 Nom. 190 Nom. 560 Secondary returns Primary flow Primary return 950 Nom. . Pocket for temperature sensors x 2 Rp ½” Socket (flow & return) 1330 Nom. Secondary flows 1140 Nom. 1740 Min 165 O/D 507 All dimensions in mm All dimensions in mm Two Boiler Arrangement E 85 419 560 crs H 550 max 600 Min 1530 300 F G (Nominal) Horizontal plane Header axis 1830 Nom. 1740 Nom. 1740 . . Header at 3° fall to horizontal. (29 mm drop between adjacent boiler terminal connections). Flow Rp ½” Socket (flow & return) 1120 128 225 190 Nom. 22mm SRV relief pipe (option) 380 Nom. Condense Return (option) 524 Nom. Gas All dimensions in mm 10 Dimensional Details Fleet Wall Hung Boiler Pipe Kits & Flue Headers Pipe Kit and Low Loss Header Connection Sizes Three Boiler Arrangement DN65 – PN16 Return 2090 DN65 – PN16 Gas Condense 85 R2" Horizontal plane 40 mm Header axis Dimensions (mm) 560 crs F G H F40W to F100W 470 233 368 150 F125W to F150W 570 304 319 200 . E Sensor Spool Kit 550 max 29 G (nominal) Header at 3° fall to horizontal. (29 mm drop between adjacent boiler terminal connections). Boiler Flue Dimensions Models H 419 300 1740 Nom. Flow 600 Min. All Models Sensor Pocket ½" BSP Rp ½” Socket (flow & return) DN65 1680 120 All dimensions in mm 2650 300 300 85 Horizontal plane 419 29 560 crs H 550 max 600 Min. Four Boiler Arrangement G (nominal) Header axis Header at 3° fall to horizontal. (29 mm drop between adjacent boiler terminal connections). 1740 . B23 open flue header vertical terminal with air inlet filter and 90° ellbow. Note...On two, three and four boiler arrangements, standard length vertical terminals are supplied for each boiler. These must be cut to length to maintain the recommended 3° fall in the main horizontal header, falling away from the main flue riser. The first terminal (for the boiler nearest to the main flue riser) does not need to be cut, but each terminal thereafter should be cut 29mm shorter than the previous terminal to achieve the recommended 3° fall. Rp ½” Socket (flow & return) 2240 All dimensions in mm 11