Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
Eaton's Cooper
Controls Business
We offer a broad portfolio of lighting control solutions
for diverse spaces, including advanced metering
systems, occupancy sensors, theatrical lighting controls,
architectural dimming controls and more. Eaton's Cooper
Controls business combines the best products from
innovative companies to provide lighting control solutions
that are high-quality and easy to use, with a low cost
of ownership.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-2
TABLE OF CONTENTS
LIGHTING CONTROL PANELS - STAND ALONE
LiteKeeper 32
Page 23-4
LiteKeeper 16
Page 23-4
LiteKeeper 8
Page 23-5
OCCUPANCY SENSORS - CEILING SENSORS
LiteKeeper 4
Page 23-5
MicroSet Dual Tech
Page 23-6
MicroSet Ultrasonic
Page 23-6
Designer Series
Ultrasonic
Page 23-7
MicroSet PIR
Page 23-7
OCCUPANCY SENSORS - CEILING SENSORS - SWITCHPACKS
OCCUPANCY SENSORS - WALL SWITCHES - NEOSWITCH
Extreme Temperature
PIR
Page 23-8
Heavy Duty
Switchpack
Page 23-9
Dual Relay
Switchpack
Page 23-9
Dual Tech, Dual Relay
No Neutral
Page 23-10
Dual Tech, Dual Relay
with Neutral
Page 23-10
Dual Tech No Neutral
Page 23-11
Dual Tech with
Neutral
Page 23-11
Dual Tech 347V
Page 23-11
Dual Tech RR7
Page 23-12
Dual Tech Low
Voltage
Page 23-12
PIR Wall Switch
Page 23-13
PIR, Dual Relay 347V
Page 23-13
PIR 347V
Page 23-13
PIR RR7
Page 23-14
PIR 347V
Page 23-16
Ultrasonic Wall
Switch 120/277V
Page 23-16
PIR, Dual Relay
Page 23-12
OCCUPANCY SENSORS - WALL SWITCHES
Vacancy with Night
Light
Page 23-14
PIR, Dual Level
120/277V
Page 23-15
PIR Wall Switch
120/277V
Page 23-15
PIR, Dual Level 347V
Page 23-15
COOPER CONTROLS
PIR Low Voltage
Page 23-14
23-3
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
30"
[762mm]
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, UL916 Listed, UL924 with RIM, California Title 24
LITEKEEPER 32
6-1/4" [159mm]
ORDERING INFORMATION
SAMPLE NUMBER: LK32-120/277-S2-L3-M1-T0-HVB1
Product Family
Voltage
Number of SRCs
Number of LRCs
Number of MRCs
Number of TPRCs
Number of High Voltage Barriers
LK32=LiteKeeper 32
120/277
120/347
220/230
S0=0 Standard Relay Card
S1=1 Standard Relay Card
S2=2 Standard Relay Cards
S3=3 Standard Relay Cards
S4=4 Standard Relay Cards
L0=0 Latching Relay Card
L1=1 Latching Relay Card
L2=2 Latching Relay Cards
L3=3 Latching Relay Cards
L4=4 Latching Relay Cards
M0=0 Modular Relay Card
M1=1 Modular Relay Card
M2=2 Modular Relay Cards
M3=3 Modular Relay Cards
M4=4 Modular Relay Cards
T0=0 Two Pole Relay Card
T1=1 Two Pole Relay Card
T2=2 Two Pole Relay Cards
T3=3 Two Pole Relay Cards
T4=4 Two Pole Relay Cards
HVB0=0 High Voltage Barrier
HVB1=1 High Voltage Barrier
HVB2=2 High Voltage Barriers
HVB3=3 High Voltage Barriers
LIGHTING CONTROL PANELS - STAND ALONE
15" [381mm]
FEATURES
rCapable of mixed load voltages (120/277/347 VAC)
r Capable of mixed sources (normal and emergency power)
r Manual and programmable control of each relay via a simple keypad
r4-line LCD display
r Normally open, latched and two pole parallel relays available
r Flush mount kit and voltage separation barrier available
rNEMA 1 enclosure
15" [381mm]
FEATURES
r Capable of mixed load voltages (120/277/347 VAC)
rCapable of mixed sources (normal and emergency power)
r Manual and programmable control of each relay via a simple keypad
r 4-line LCD display
rNormally open, latched and two pole parallel relays available
r Flush mount kit and voltage separation barrier available
r NEMA 1 enclosure
18"
[457mm]
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, UL916 Listed, UL924 with RIM, California Title 24
6-1/4" [159mm]
LITEKEEPER 16
ORDERING INFORMATION
SAMPLE NUMBER: LK16-120/277-S1-L1-M0-T0-HVB1
Product Family
Voltage
Number of SRCs
Number of LRCs
Number of MRCs
Number of TPRCs
Number of High Voltage Barriers
LK16=LiteKeeper 16
120/277
120/347
220/230
S0=0 Standard Relay Card
S1=1 Standard Relay Card
S2=2 Standard Relay Cards
L0=0 Latching Relay Card
L1=1 Latching Relay Card
L2=2 Latching Relay Cards
M0=0 Modular Relay Card
M1=1 Modular Relay Card
M2=2 Modular Relay Cards
T0=0 Two Pole Relay Card
T1=1 Two Pole Relay Card
T2=2 Two Pole Relay Cards
HVB0=0 High Voltage Barrier
HVB1=1 High Voltage Barrier
COOPER CONTROLS
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-4
LIGHTING CONTROL PANELS - STAND ALONE
9-1/2" [241mm]
FEATURES
r Manual and programmable control of each relay via a simple keypad
r 2-line LCD display
r Normally open, latched and two pole parallel relays available
r Uses parallel relay cards
r Eight relays and eight low voltage input connections
r Time schedules with astronomic clock
r Flush mount kit available
r NEMA 1 enclosure
14"
[356mm]
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, UL916 Listed, California Title 24
LK8
5" [127mm]
LK8-LRC/LK8-MRC/LK8-TPRC
7" [177mm]
LITEKEEPER 8
ORDERING INFORMATION
SAMPLE NUMBER: LK8-LRC
Product Family
Options
LK8=LiteKeeper 8
347=Canada 347 VAC Transformer with LRC
LRC=Latching Relay Card
MRC=Modular Relay Card
TPRC=Two Pole Relay Card
14" [356mm]
FEATURES
r Manual and programmable control of each relay via a simple keypad
r 2-line LCD display
r Normally open relays
r Relays built onto control board
r Four - 20A relays and four low voltage input connections
r Time schedules with astronomic clock
r Prioritization and masking switch inputs, time schedules and remotes
r NEMA 1 enclosure
9-1/2"
[241mm]
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, UL916 Listed, California Title 24
LITEKEEPER 4
ORDERING INFORMATION
SAMPLE NUMBER: LK4-120NO
Input Voltage
Relay Type
LK4=LiteKeeper 4
120=120V
277=277V
NO=Normally Open
COOPER CONTROLS
Product Family
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
23-5
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
3-1/4" [83mm]
Hot
Line Neutral
Black
Red
Blue
** Hot
White
Blue
** Hot
White
Blue
Hot
Line Neutral
Load 1
Blue
Black
Red
Blue
Switchpack
Load 2
Blue
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Switchpack
Classroom - energy saver
option/dual level operation.
Optional Greengate AML switch
For manual on or off capability.
Yellow
Brown
Orange (normally open)
Gray (common)
Purple (normally closed)
COMPLIANCES: UL Listed, California Title 24
Blue
Red
Black
**Use black lead for 120 VAC. Use orange lead for
277 VAC. Cap unused lead.
MICROSET DUAL
TECH
ORDERING INFORMATION
SAMPLE NUMBER: OMC-DT-2000-R
Catalog Number
Recommended Room Size
Field of View
Features
OMC-DT-2000-R
700 - 2,000 square feet
Two-Way (360°)
With BAS Relay
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL Listed, California Title 24
Hot
Load
Blue
**Hot
Neutral
White
Line
Blue
Black
Blue
Red
FEATURES
r No adjustment necessary at installation
rContinuous, real-time, self-adjusting sensitivity and time delay
rComplete no-gap coverage
r Ideal for spaces needing sensitivity to minor motion detection
rManual ON/OFF feature when wired to a momentary pushbutton
rNEMA WD7 Guide robotic method
OCCUPANCY SENSORS - CEILING SENSORS
FEATURES
rExclusive Energy Saver mode
rComplete no-gap coverage
r Self-adjustable delay of 10 minutes to 30 minutes
rBAS compatible
rManual ON/OFF feature when wired to a momentary pushbutton
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
To Additional
Switchpacks
(Max. of 10)
Brown
Greengate
AML Switch
Switchpack
*manual Off Switch
(Optional)
To additional Sensors
(Max. of 5 per Switchpack)
Orange (N/O Closed Upon Motion)
Gray (Common)
Purple (N/C Closed Upon No Motion)
**Use black lead for 120 V/AC. Use orange lead
for 277 V/AC. Cap unused lead.
MICROSET
ULTRASONIC
ORDERING INFORMATIO
A
N
SAMPLE NUMBER: OMC-U-0501
Catalog Number
Recommended Room Size
Field of View
OMC-U-0501
Up to 500 square feet
One-Way (180°)
OMC-U-0501-R
Up to 500 square feet
One-Way (180°)
OMC-U-1001
500 - 1,000 square feet
One-Way (180°)
OMC-U-1001-R
500 - 1,000 square feet
One-Way (180°)
OMC-U-2000
1,000 - 2,000 square feet
Two-Way (360°)
OMC-U-2000-R
1,000 - 2,000 square feet
Two-Way (360°)
Features
With BAS Relay
With BAS Relay
With BAS Relay
COOPER CONTROLS
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-6
Line
Load
Blue
**Hot
White
Neutral
Blue
Black
Blue
Red
OCCUPANCY SENSORS - CEILING SENSORS
Hot
FEATURES
r Ultrasonic technology
r Complete no-gap coverage
r Ideal for spaces needing increased sensitivity to minor motion
r Adjustable sensitivity and time delay
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL Listed, California Title 24
*manual Off Switch
(Optional)
Switchpack
To additional Sensors
(Max. of 5 per Switchpack)
To Additional
Switchpacks
(Max. of 10)
Orange (N/O Closed Upon Motion)
Gray (Common)
Purple (N/C Closed Upon No Motion)
DESIGNER SERIES
ULTRASONIC
**Use black lead for 120 V/AC. Use orange lead
for 277 V/AC. Cap unused lead.
ORDERING INFORMATIO
A
N
SAMPLE NUMBER: ODC-U-0501
Catalog Number
Recommended Room Size
Field of View
ODC-U-0501
Up to 500 square feet
One-Way (180°)
ODC-U-0501-R
Up to 500 square feet
One-Way (180°)
ODC-U-1001
500 - 1,000 square feet
One-Way (180°)
ODC-U-1001-R
500 - 1,000 square feet
One-Way (180°)
ODC-U-2000
1,000 - 2,000 square feet
T
Two-W
ay (360°)
ODC-U-2000-R
1,000 - 2,000 square feet
Two-W
T
ay (360°)
ODC-U-0051-H
50 linear feet
One-Way (180°)
ODC-U-0051-H-R
50 linear feet
One-Way (180°)
ODC-U-0100-H
100 linear feet
T
Two-W
ay (360°)
ODC-U-0100-H-R
100 linear feet
T
Two-W
ay (360°)
Features
With BAS Relay
With BAS Relay
With BAS Relay
Hallways
With BAS Relay
With BAS Relay
Load
Blue
Red
Blue
* Manual-off Switch (optional)
Switchpack
Optional Greengate aml switch
For manual on or off capability
Black
Red
Blue
Yellow (daylight control)
Brown
Orange (normally open)
Gray (common)
Purple (normally closed)
COMPLIANCES: UL/cUL Listed, California Title 24
MICROSET PIR
*Use only one manual-off option.
**Use black lead for 120VAC. Use orange lead
for 277 VAC. Cap unused lead.
ORDERING INFORMATION
SAMPLE NUMBER: OMC-P-1200-R
Catalog Number
Recommended Room Size
Mounting
Features
OMC-P-1200-R
1,200 square feet
Surface Mounted
With BAS Relay and Daylight Sensor
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
23-7
Blue
** Hot
Neutral
Black
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COOPER CONTROLS
* Manual-off Switch (optional)
Hot
Line
White
FEATURES
r Passive Infrared technology
r No adjustments necessary at installation
r Continuous, real-time, self-adjusting sensitivity and time delay
r DIP Switch override allows time delay to be locked at 30 minutes
r Manual ON/OFF feature when wired to momentary pushbutton
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
Hot
Blue
**Hot
*Manual
Off Switch
(optional)
Load
Red
Blue
Black
Blue
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL Listed, California Title 24
*Use only one
Manual Off
Switch option
Neutral
White
Line
*Manual Off
Switch (optional)
To additional
Switchpacks
(max. of 10)
Switchpack
To additional sensors
(Max. of 5 per
switchpack)
Orange (normally open)
Grey (common)
Purple (normally closed)
**Use black lead for 120 VAC. Use orange lead
for 277 VAC. Cap unused lead.
EXTREME
TEMPERATURE PIR
ORDERING INFORMATION
SAMPLE NUMBER: OXC-P-1500-R
Catalog Number
Recommended Room Size
Field of View
Features
OXC-P-1500-R
Up to 1,500 square feet
Two-Way (360°)
With BAS Relay and Daylight Sensor
OCCUPANCY SENSORS - CEILING SENSORS
FEATURES
r UL listed for damp locations
rStable sensitivity at temperatures from -40°F to 125°F (-40°C to 52°C)
rBuilt-in photocell
r BAS compatible
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
COOPER CONTROLS
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-8
Hot
Blue
Neutral
Use black lead for
120 VAC. Use orange
lead for 277 VAC
cap unused lead
White
Line
Red
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL Listed, CSA Listed, California Title 24
Black
Blue
Blue
OCCUPANCY SENSORS - CEILING SENSORS - SWITCHPACKS
Hot
FEATURES
r Replaces separate transformers and relays
r Zero-crossing circuit provides increased durability
r Capable of switching up to 20 amps
r Suitable for plenum use
r Rated for ballast, tungsten and motor loads
Load A
Load B
Ceiling Sensor
A/B Switching
HEAVY DUTY
SWITCHPACK
ORDERING INFORMATION
SAMPLE NUMBER: SP20-MV
Catalog Number
Ratings
Ballast
Tungsten
Motor (HP)
Output
SP20-MV
120/277 VAC
20A
15A, 120V
1HP-120V, 2HP-250V
15 VDC, 125mA
Hot
FEATURES
r Used where two circuits need to be controlled at the same point
r Replaces separate transformers and relays
r Zero-crossing circuit provides increased durability
r Capable of switching up to 20 amps
r Suitable for plenum installations
r Rated for ballast, tungsten and motor loads
Line
Neutral
*Use black lead for 120VAC
Use orange lead for 277VAC
Red
Blue
Yellow
Black
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Red
Blue
Black
COMPLIANCES: UL Listed, CSA Listed, California Title 24
Hot**
White
Blue
Blue
Red
Red
DUAL RELAY
SWITCHPACK
ORDERING INFORMATION
SAMPLE NUMBER: SPD20-MV-NO
Ratings
Ballast
Tungsten
Motor (HP)
Output
SPD20-MV-NO
120/277 VAC
20A, 120 VAC
20A, 277 VAC
15A, 120 VAC
1HP-120V, 2HP-250V
24 VDC, 125mA
COOPER CONTROLS
Catalog Number
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
23-9
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
*Optional Manual Off
(Toggle Switches)
Load 1
Load 2
120/277 VAC
Black
Blue
Red
Red
Green
Load 2
Load 1
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Neutral
DUAL TECH,
DUAL RELAY NO
NEUTRAL
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-DMV
Catalog Number
Ratings
Coverage
Voltage
ONW-D-1001-DMV
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277 VAC, 50/60 Hz
120/277 VAC
Blue
Red
Green
Load 2
Load 1
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Black
Red
Neutral
White
FEATURES
rUltrasonic and Passive Infrared technologies
r Dual relay provides control of two separate loads
rNo minimum load required
r1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
rSelectable built-in light level sensor
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
OCCUPANCY SENSORS - WALL SWITCHES - NEOSWITCH
FEATURES
rUltrasonic and Passive Infrared technologies
r Dual relay provides control of two separate loads
r No neutral required; no minimum load required
r1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
r100% recycled packaging
DUAL TECH,
DUAL RELAY WITH
NEUTRAL
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-DMV-N
Catalog Number
Ratings
Coverage
Voltage
ONW-D-1001-DMV-N
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277 VAC, 50/60 Hz
COOPER CONTROLS
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-10
OCCUPANCY SENSORS - WALL SWITCHES - NEOSWITCH
FEATURES
r Ultrasonic and Passive Infrared technologies
r No neutral required
r No minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
120/277 VAC
Blue
Black
Green
Load
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Neutral
DUAL TECH NO
NEUTRAL
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-MV
Catalog Number
Ratings
Coverage
Voltage
ONW-D-1001-MV
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277 VAC, 50/60 Hz
FEATURES
r Ultrasonic and Passive Infrared technologies
r No minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
120/277 VAC Black
Blue
Green
White
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
DUAL TECH WITH
NEUTRAL
Load
Ground
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Neutral
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-MV-N
Catalog Number
Ratings
Coverage
Voltage
ONW-D-1001-MV-N
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277 VAC, 50/60 Hz
COOPER CONTROLS
FEATURES
r Ultrasonic and Passive Infrared technologies
r No neutral required
r No minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
347 VAC
Black
Blue
Green
Load
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
DUAL TECH 347V
Neutral
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-347
Catalog Number
Ratings
Coverage
Voltage
ONW-D-1001-347
Incandescent: 0-1500W at 347V; Fluorescent: 0-1500W at 347V, Maximum Load/Relay
180°, 1000 square feet
347 VAC, 50/60 Hz
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
23-11
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
Neutral
Relay
Blue
Red
Black
24 VAC
Orange (N.O.)
Gray (common)
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Load
Hot
Purple (N.C.)
White
Red
To
Additional
Relays
Black
Use only approved relays: GE RR7 type maximum
of four or sierra 1070-B type maximum of two.
DUAL TECH RR7
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-RR7
Catalog Number
Ratings
Coverage
ONW-D-1001-RR7
24 VAC input with Isolated Form C Relay (Half Wave Rectified)
180°, 1000 square feet
Red (10-30VDC)
Orange (N.O.)
Blue (Control)
Gray (Common)
Purple (N.C.)
Red
Blue
Black
Black (Common)
Line
Hot
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Hot
White
Blue
Blue
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Neutral
FEATURES
r Ultrasonic and Passive Infrared technologies
rLow voltage unit
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
rSelectable built-in light level sensor
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
r Tracking/HVAC mode
r100% recycled packaging
OCCUPANCY SENSORS - WALL SWITCHES - NEOSWITCH
FEATURES
r Ultrasonic and Passive Infrared technologies
rLow voltage unit interfaces directly with GE RR7 relay systems
r1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
rSelectable built-in light level sensor
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
r Tracking/HVAC mode
r100% recycled packaging
Load
DUAL TECH LOW
VOLTAGE
ORDERING INFORMATION
SAMPLE NUMBER: ONW-D-1001-SP
Catalog Number
Ratings
Coverage
ONW-D-1001-SP
10-30 VDC input with Isolated Form C Relay
180°, 1000 square feet
FEATURES
r Passive Infrared technology
r Dual relay provides control of two separate loads
rNo minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
rSelectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
120/277 VAC
Black
Blue
Red
Red
Green
Load 2
Load 1
Ground
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Neutral
PIR, DUAL RELAY
ORDERING INFORMATION
SAMPLE NUMBER: ONW-P-1001-DMV
Catalog Number
Ratings
Coverage
Voltage
ONW-P-1001-DMV
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277VAC, 50/60 Hz
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-12
COOPER CONTROLS
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
OCCUPANCY SENSORS - WALL SWITCHES - NEOSWITCH
FEATURES
r Passive Infrared technology
r No minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
120/277 VAC
Black
Blue
Green
Load
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Neutral
PIR WALL SWITCH
ORDERING INFORMATION
SAMPLE NUMBER: ONW-P-1001-MV
Catalog Number
Ratings
Coverage
Voltage
ONW-P-1001-MV
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277 VAC, 50/60 Hz
FEATURES
r Passive Infrared technology
r Dual relay provides control of two separate loads
r No minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
347 VAC
Black
Blue
Red
Red
Green
Load 2
Load 1
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Neutral
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
PIR, DUAL RELAY
347V
ORDERING INFORMATION
SAMPLE NUMBER: ONW-P-1001-D347
Catalog Number
Ratings
Coverage
Voltage
ONW-P-1001-D347
Incandescent: 0-1500W at 347V; Fluorescent: 0-1500W at 347V, Maximum Load/Relay
180°, 1000 square feet
347 VAC, 50/60 Hz
FEATURES
r Passive Infrared technology
r No minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
347 VAC
Black
Blue
Green
Load
COOPER CONTROLS
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Ground
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Neutral
PIR 347V
ORDERING INFORMATION
SAMPLE NUMBER: ONW-P-1001-347
Catalog Number
Ratings
Coverage
Voltage
ONW-P-1001-347
Incandescent: 0-1500W at 347V; Fluorescent: 0-1500W at 347V, Maximum Load/Relay
180°, 1000 square feet
347 VAC, 50/60 Hz
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
23-13
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
Neutral
Load
Hot
Relay
Blue
Red
Black
24 VAC
Orange (N.O.)
Gray (common)
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
OCCUPANCY SENSORS - WALL SWITCHES - NEOSWITCH
FEATURES
rPassive Infrared technology
rLow voltage unit interfaces directly with GE RR7 relay systems
r 1000 square feet of coverage
rAir-gap switch ensures no leakage current to load
rSelectable built-in light level sensor
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
rTracking/HVAC mode
r100% recycled packaging
Purple (N.C.)
White
Red
To
Additional
Relays
Black
Use only approved relays: GE RR7 type maximum
of four or sierra 1070-B type maximum of two.
PIR RR7
ORDERING INFORMATION
SAMPLE NUMBER: ONW-P-1001-RR7
Catalog Number
Ratings
Coverage
ONW-P-1001-RR7
24 VAC input with Isolated Form C Relay (Half Wave Rectified)
180°, 1000 square feet
Red (10-30VDC)
Orange (N.O.)
Blue (Control)
Purple (N.C.)
Red
Black
Black (Common)
Blue
Gray (Common)
Line
Hot
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
Hot
White
Blue
Blue
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Neutral
FEATURES
r Passive Infrared technology
r Low voltage unit
r1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
r Selectable built-in light level sensor
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
r Tracking/HVAC mode
r 100% recycled packaging
PIR LOW VOLTAGE
Load
ORDERING INFORMATION
SAMPLE NUMBER: ONW-P-1001-SP
Catalog Number
Ratings
Coverage
ONW-P-1001-SP
10-30 VDC input with Isolated Form C Relay
180°, 1000 square feet
FEATURES
r Passive Infrared technology
r Amber LED night light illuminates when overhead lights are OFF
rNo minimum load required
r 1000 square feet of coverage
r Air-gap switch ensures no leakage current to load
rNEMA WD7 Guide robotic method utilized to verify coverage patterns
r 100% recycled packaging
120/277 VAC
Black
Green
Blue
White
Load
Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
Neutral
VACANCY WITH
NIGHT LIGHT
ORDERING INFORMATION
SAMPLE NUMBER: VNLW-P-1001-MV-N
Catalog Number
Ratings
Coverage
Voltage
VNLW-P-1001-MV-N
Incandescent: 0-800W at 120V; Fluorescent: 0-1200W at 120V; Fluorescent: 0-2700W at 277V, Maximum Load/Relay
180°, 1000 square feet
120/277 VAC, 50/60 Hz
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
23-14
COOPER CONTROLS
COMPLIANCES: UL/cUL Listed, California Title 24, RoHS Compliant
OCCUPANCY SENSORS - WALL SWITCHES
120 VAC or 277 VAC
FEATURES
r Passive Infrared technology
r 120 and 277V in the same unit
r Dual relay provides control of two separate loads
r Exclusive Energy Saver mode
r Zero-crossing technology maximizes relay life and ensures longevity
r No minimum load required
r Air-gap switch ensures no leakage current to load
r Manual OFF pushbutton can be used in either mode
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
Black
Red
Red
Blue
Green
Green/Yellow
Load 1
Switchleg
Load 2
Switchleg
Bare Wire Ground
Load 2
Load 1
**
277 VAC Ground
120 VAC Ground
Load 1 Neutral
Load 2 Neutral
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
**Use the appropiate ground for the voltage
connected to black wire. Use one ground lead
only, cap unused lead.
COMPLIANCES: UL/cUL Listed, California Title 24
PIR, DUAL LEVEL
120/277V
ORDERING INFORMATION
SAMPLE NUMBER: OSW-P-0451-DMV
Catalog Number
Ratings
Coverage
Shut-off Delay
OSW-P-0451-DMV
Incandescent: 0-800W at 120V; Fluorescent: 0-800W at 120V; Fluorescent: 0-1200W at 277V, Maximum Load/Relay
180°, 450 square feet
Adjustable 15 sec. - 30 min.
120 VAC or 277 VAC
FEATURES
r Passive Infrared technology
r 120 and 277V in the same unit
r Zero-crossing technology maximizes relay life and ensures longevity
r No minimum load required
r Air-gap switch ensures no leakage current to load
r Manual OFF pushbutton can be used in either mode
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
Black
Blue
Green
Green/Yellow
Bare Wire
Ground
Load
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, California Title 24
277 VAC Ground
120 VAC Ground
Neutral
PIR WALL SWITCH
120/277V
**Use one ground lead only, cap unused lead.
ORDERING INFORMATION
SAMPLE NUMBER: OSW-P-0451-MV
Catalog Number
Ratings
Coverage
Shut-off Delay
OSW-P-0451-MV
Incandescent: 0-800W at 120V; Fluorescent: 0-800W at 120V; Fluorescent: 0-1200W at 277V, Maximum Load/Relay
180°, 450 square feet
Adjustable 15 sec. - 30 min.
COOPER CONTROLS
FEATURES
r Passive Infrared technology
r 347 VAC
r Dual relay provides control of two separate loads
r Exclusive Energy Saver mode
r Zero-crossing technology maximizes relay life and ensures longevity
r No minimum load required
r Air-gap switch ensures no leakage current to load
r Manual OFF pushbutton can be used in either mode
r NEMA WD7 Guide robotic method utilized to verify coverage patterns
347 VAC
Bare Wire Ground
Black
Red
Red
Blue
Green
Load 1
Switchleg
Load 2
Switchleg
Load 1
347 VAC Ground
Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.
COMPLIANCES: UL/cUL Listed, CSA Listed
Load 1 Neutral
Load 2 Neutral
PIR, DUAL LEVEL
347V
ORDERING INFORMATION
SAMPLE NUMBER: OSW-P-0451-D347
Catalog Number
Ratings
Coverage
Shut-off Delay
OSW-P-0451-D347
Fluorescent: 0-600W at 347V, Maximum Load/Relay
180°, 450 square feet
Adjustable 15 sec. - 30 min.
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.
23-15
Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com
Load 2
Bur
naby
39352ndAvenue
Bur
naby
,BCV5C3W9
T
el
:6042924800
Cr
anbr
ook
Uni
tA#800I
ndus
t
r
i
alRoad.#2
Cr
anbr
ook,BCV1C4C9
T
el
:2504894591
Daws
onCr
eek
110197t
hAvenue
Daws
onCr
eek,BCV1G1N5
T
el
:2507824896
Langl
ey
#101-20550DuncanWay
Langl
ey
,BCV3A7A3
T
el
:6045331275
Kaml
oops
B983Camos
unCr
es
cent
Kaml
oops
,BCV2C6G1
T
el
:2503743191
For
tNel
s
on
POBox3266-501648t
hAvenue
For
tNel
s
on,BCV0C1R0
T
el
:2502338570
Ri
chmond
12360Vi
cker
sWay
Ri
chmond,BCV6V1H9
T
el
:6042731981
Pent
i
ct
on
401OkanaganAvenue
Pent
i
ct
on,BCV2A3K1
T
el
:2504924032
Ki
t
i
mat
622Commer
ci
alAvenue
Ki
t
i
mat
,BCV8C2C5
T
el
:2506323774
Sur
r
ey
1305580t
hAvenue
Sur
r
ey
,BCV3W 3B1
T
el
:6045967111
Ver
non
520324t
hSt
r
eet
Ver
non,BCV1T8X7
T
el
:2505452191
Pr
i
nceGeor
ge
2255S.Qui
nnSt
r
eet
Pr
i
nceGeor
ge,BCV2N2X4
T
el
:2505630575
Wi
l
l
i
amsLake
527S.MacKenz
i
eAvenue
Wi
l
l
i
amsLake,BCV2G1C8
T
el
:2503927795
T
er
r
ace
5000Pohl
eAvenue
T
er
r
ace,BCV8G4S8
T
el
:2506356379
Campbel
lRi
ver
1030B-9t
hAvenue
Campbel
lRi
ver
,BCV9W 4C2
T
el
:2502879265
Cour
t
enay
2615Mor
ayPl
ace
Cour
t
enay
,BCV9N8A9
T
el
:2503340338
Duncan
5286Pol
keyRoad
Duncan,BCV9L6W3
T
el
:2507483377
Uni
t9,722368Avenue,
Edmont
on,Al
ber
t
a T6B3T6
Pr
oces
s
,Aut
omat
i
on&
Cont
r
ol
sGr
oup
T
el
:7785459916
Pr
oj
ect
sGr
oup
T
el
:6045967111
Dat
aCommuni
cat
i
onsGr
oup
T
el
:7785459916
Li
ght
i
ngSpeci
al
i
s
t
T
el
:7785459916
Par
ks
vi
l
l
e
#105-425E.St
anf
or
dAvenue
Par
ks
vi
l
l
e,BCV9P2N4
T
el
:2509541797
HeadOf
f
i
ce
1929525t
hAvenue
Sur
r
ey
,BCV3Z3X1
T
el
:7785459916
Fax:7785453099
T
ol
lFr
ee:18884677626
Download