TECHNICAL BULLETIN EYE Cera Arc® CERAMIC METAL HALIDE CMTP270/BUD/941/PS ANSI CODE: Use with Proprietary Electronic Ballast only ML270/O* Product Code: 55161 • High initial and maintained lumens • Long Life • Superior lamp to lamp color consistency FEATURES: • High Color Rendering • TCLP Compliant • Energy Saving Design PERFORMANCE DATA Mean lumens at 11 hours/start Rated average life Warm-up time (90%lumens) Correlated color temperature CIE Chromaticity Color rendering index (CRI) Operating position 29000 lm 26100** See Note #1 lm hr <6 4100° min °K 0.378, 0.385 Ra:92 R9:40 X,Y RELATIVE ENERGY % Initial lumens 100 80 60 40 20 0 Base Up, Base Down Time to re-start (max) <10 380 430 480 530 580 630 680 730 780 min WAVE LENGTH(nm) ELECTRICAL CHARACTERISTICS LUMEN MAINTENANCE W Nominal lamp voltage 125 V Nominal lamp current 2.2 ARMS Proprietary Electronic PHYSICAL DESCRIPTION Effective arc length 20(0.79) mm (in) Maximum overall length 214(8.43) mm (in) Light center length 127(5.0) mm (in) Bulb diameter 46(1.81) mm (in) 3° max Maximum base temperature 210 (410) °C (°F) Maximum bulb temperature 400 (752) °C (°F) Base to bulb eccentricity Bulb designation Bulb material T14.5 Borosilicate (hard glass) Arc tube material PCA Bulb finish Clear Base designation EX39 FIXTURE REQUIREMENTS O-Rated - Open Fixture 100% % INITIAL LUMENS 270 80% 60% 40% 20% 0% 0% 20% 40% 60% 80% 100% 80% 100% % RATED LIFE LAMP MORTALITY % LAMPS STILL BURNING Nominal lamp wattage Ballast requirements SPECTRAL DISTRIBUTION 100% 80% 60% 40% 20% 0% 0% 20% 40% 60% Note #1: % RATED LIFE Rated Average Life is 24,000 hrs or 2,000 Starts adhering to the following conditions: a) Minimum ON time = 15 minutes b) Minimum OFF time = 15 minutes c) Maximum Dimming = 30% (70% Full Power) after initial 15 min ON time d) Lamps can be dimmed up to 65% of lifetime, but with the affect of reduced lumen maintenance * At the time of this release ANSI does not yet have electronic ballast standards for this lamp wattage. However, all reported lamp performance data is in agreement with the Manufacturer’s expectations for this lamp design. ** Limited testing is not sufficient at this time to accurately predict Mean Lumens, Lumen Depreciation or Lamp Mortality. The information provided is based on existing lamp types of similar design. OSHAS 18001:2007 Certified ISO 17025:2005 Accredited ISO 9001:2008 Certified ISO 14001:2004 Certified Address: 9150 Hendricks Rd., Mentor, OH 44060 Phone: 888-66-LAMPS Fax: 800-811-735 E-Mail: sales@eyelighting.com Phone: (440) 350-7000 Fax: (440) 350-7001 www.eyelighting.com EQS-N-52-78-55161 9FEB16 Rev:3 TECHNICAL BULLETIN EYE Cera Arc® CERAMIC METAL HALIDE CMTP270/BUD/941/PS WARNING This lamp can cause serious skin burn and eye inflammation from short-wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. ! RISK OF ELECTRIC SHOCK •Turn power off before inspection, installation or removal •Protect lamp from direct contact with liquids to avoid breakage from thermal shock RISK OF FIRE •Keep combustible materials away from lamp during operation UNEXPECTED LAMP RUPTURE MAY CAUSE INJURY, FIRE, OR PROPERTY DAMAGE •Do not exceed rated ballast voltage •Do not use lamp if outer glass is scratched or broken. •Do not use beyond rated life •Do not turn on lamp until fully installed •Use only with a fixture and ballast rated for this product •Turn lamp off at least once a week for 15 minutes •Electrically insulate any metal to glass support in fixture CAUTION EXCESSIVE FORCE DURING LAMP INSTALLATION •Do not use excessive force when installing lamp as glass jacket may shatter and cause injury •Use packaging sleeve to hold lamp during installation to prevent over-tightening in socket RISK OF BURN •Allow lamp to cool before handling. Dispose of lamp in a closed container. ! LAMP OPERATING INSTRUCTIONS This is a discharge lamp and requires some time to restart and come up to full brightness after a power interruption. If power supply dips or is interrupted, lamps may extinguish and not restart. If this occurs, keep the power OFF for 15 minutes to allow lamp to cool down before restriking. Otherwise, damage to the arc tube may occur resulting in shortened lamp life or reduced lumen output. R Conforms to: USA: 21CFR1040.30 Hg Canada: ANSI 136.1-2000 Lamp contains Mercury. Manage in Accord with Disposal Laws See : www.lamprecycle.org or 1-888-665-2677 OSHAS 18001:2007 Certified ISO 17025:2005 Accredited ISO 9001:2008 Certified ISO 14001:2004 Certified Address: 9150 Hendricks Rd., Mentor, OH 44060 Phone: 888-66-LAMPS Fax: 800-811-735 E-Mail: sales@eyelighting.com Phone: (440) 350-7000 Fax: (440) 350-7001 www.eyelighting.com EQS-N-52-78-55161 9FEB16