Lighting Performance Checklist: Football Prior to being approved for a televised event, facility must submit this checklist at least 4 months before the event to: Dr. Kurt Patberg (commissioner@ssacsports.com), Phone 770/447/5700. Inspection must be completed by a qualified lighting technician using a light meter calibrated within the last 12 months. Press "TAB" to navigate to cells to enter your data. Average footcandles and uniformity values automatically calculate when you enter the light readings at each point on the field. Date of Inspection: College / University Name: College / University Contact: Telephone: Facility Name: Facility Address: Inspected by: Email: Instructions - Horizontal Footcandle Readings: Complete for all field surveys. Grid field as shown on the field drawing below starting at 0,0. Readings are taken in the middle of each square with light meter held 36 inches above ground, pointing up. Number of grid points will vary depending on field size & layout. To obtain average footcandle value: 1. Record light level readings within each square 2. Total all readings, divide by number of grid readings taken To obtain uniformity ratio: 1. Divide highest (maximum) light level reading by the lowest (minimum) light level reading 30' x 30' grid City, State, Zip: Horizontal Footcandle & Field Survey Results: Average footcandles: Uniformity: Quantity of poles: :1 (mark approximate locations with an X just outside the field perimeter on the layout below) Total # luminaires: # luminaires operational: Lamp wattage: System voltage(if available): Date lighting system installed: Lighting Manufacturer: Date of last group relamp: Annual hours of operation: Light meter brand: Model #: Calibration Date: Include facility photographs that may be helpful for camera or temporary lighting equipment locations, such as end zones, press box, inside and outside facility, and overhead shot(s) if available. Field Orientation: © 2010 Southern States Athletic Conference (Please indicate field orientation in cells around diagram below.) Facility Name: Press Box Camera Vertical Footcandle Readings: Complete only if televised levels apply. Readings are taken in the middle of each square with light meter held 36 inches above the ground, pointing towards center line camera. End Line Camera Vertical Footcandle Readings: Complete only if televised levels apply. Readings are taken in the middle of each square with light meter held 36 inches above the ground, pointing towards end line camera location. Adapted from NCAA Best Lighting Practices and used with permission. © 2010 Southern States Athletic Conference Press Box Camera Vertical Footcandle Results: Average footcandles: Uniformity: :1 End Line Camera Vertical Footcandle Results: Average footcandles: Uniformity: :1