IP 65 (NEMA Type 4) Enclosure Gasket Installation

Installing the Gasket

Instructions

IP 65 (NEMA Type 4) Enclosure

Gasket Installation

This publication will guide you through the steps needed to install a gasket on IP 65 (NEMA Type 4) enclosures. Installation of the gasket allows additional protection for your enclosure. Two kits are available for the following:

• A1-A3 Frame Enclosures

• A4-B1 Frame Enclosures

Each kit consists of three (3) gasket sections.

!

ATTENTION: To avoid a shock hazard, assure that all power to the drive has been removed before proceeding.

Refer to Figure 1 for component identification and locations.

1. Remove and lock-out all incoming power to the drive.

2. Remove the enclosure door by pulling the two (2) hinge pins out.

3. Locate the Top Gasket and check for proper fit. The gasket should rest against the top enclosure flange and the gasket tab should touch the left enclosure flange. Remove the protective backing from the gasket and press in place.

4. Locate the Right Gasket. Check for proper fit by placing the gasket against the right enclosure flange. The top edge will meet with the Top Gasket. Remove the protective backing from the gasket and press in place.

5. Locate the Bottom Gasket and check for proper fit. The right end of the gasket should touch the Right Gasket. The top of the gasket must rest against the enclosure flange. Remove the protective backing from the gasket and press in place.

6. Replace enclosure door - installation is complete.

2 IP 65 (NEMA Type 4) Enclosure Gasket Installation

Figure 1

Gasket Installation

Enclosure Flange

Gasket Tab

Door Hinge & Pin

(2 Places)

Top Gasket

Right Gasket

Bottom Gasket

Publication 1336 PLUS-5.74 – March, 1999 P/N 193645 (01)

Copyright 1999 Rockwell International Corporation. All rights reserved. Printed in USA.