200130 Dual Pressure flexiTIM Module and 200132 Pressure

advertisement
Specifications and Ordering Information
200130 Dual Pressure flexiTIM Module
and 200132 Pressure Transducer
Description
The Dual Pressure flexiTIM™ module interfaces two individual pressure
transducers to the Trendmaster 2000 System and is intended for nondynamic pressure applications.
The flexiTIM™ module, and cable, interfaces with pressure transducers using
a four-pin, locking bayonet connection. Intended transducers for interface are
standard, millivolt output type devices having an output sensitivity of 10
mV/V. This flexibility allows measurement of a wide range of pressures over
a variety of operating conditions. A standard transducer is offered for use
with the flexiTIM™ module for convenience.
Specifications
All specifications are at 25°C (77°F) unless otherwise specified.
Operation outside the specified limits will result in false or inaccurate readings.
200130 Dual
Pressure flexiTIM
Electrical
For Reference Only – See Document #141576
Full Scale Range:
The Trendmaster full scale pressure range is set by the
pressure transducer. The transducer's full scale range is
entered into the Trendmaster software.
Accuracy:
±8.5% of the transducer's full scale rating (transducer's
accuracy not included).
Transducer Excitation
Voltage:
4.98 Vdc ±65 mVdc.
Maximum Transducer
Supply Current:
2.5 mA ABS MAX available over temperature.
Transducer OK
Range:
1 V to 3 Vdc bias from transducer (nominal).
Resolution:
0.025% of transducer's full scale rating.
Transducer:
Bridge type meeting stated requirements.
Page 1 of 6
Installed without barriers
per drawing 136926
Environmental Limits
Operating
Temperature:
-40°C to +100°C (-40°F to +212°F).
Humidity:
100% Condensing on exposed surfaces.
100% Non-condensing on surfaces inside
conduit.
Class I, Div 2, Groups A, B, C & D
T4, Ta = 100°C
CENELEC:
4
Installed with intrinsically
safe zener barriers per
drawing 136925
Housing
Materials:
Powder-Coated Aluminum.
200131 Cables
Weight:
554 grams (20 oz) not including conduit body
Dimensions:
See diagram
Enclosure
Type:
Ex nA IIC, Class I, Zone 2
T4, Ta = 100°C
II 1 G
EEx ia IIC T4, Ta = 100°C
LCIE 99 ATEX 6001X
Mechanical
Operating
Temperature:
Minimum Bend
Radius:
-20°C to +100° C (-4°F to +212°F).
25.4 mm (1 in).
Construction:
Four conductor (22 AWG) with foil
shield and drain wire (100% coverage),
yellow PVC outer jacket.
Connectors:
Screw-on, five-pin, keyed connector on
the flexiTIM end and a PT06F8-4S (or
equivalent) on the transducer end. The
environmental boot should be installed
over the transducer’s connector and
body.
Electromagnetic Compatibility
Radiated Emissions:
EN 55022 (1994). Class A.
Electrostatic Discharge:
EN 61000-4-2 (1995), Criteria A.
Radiated Susceptibility:
EN 61000-4-3 (1997) (ENV 50140 :
1993), Criteria A.
Conducted Susceptibility:
ENV 50141 (1993), Criteria A.
Electrical Fast Transient:
EN 61000-4-4 (1995), Criteria A.
200132 Pressure Transducer
Surge Capability:
ENV 50142 (1994), Criteria A.
30, 50, 100, 300, and 500.
Magnetic Field:
EN 61000-4-8 (1994), Criteria A.
Pressure Ranges
PSI SG:
Sensitivity:
10 mV/V ±1%.
Hazardous Area Approvals
Absolute Accuracy:
CSA:
Installed with intrinsically
safe zener barriers per
drawing 136925
± 4% over compensated temperature
range.
Class I, Div 1 Groups A, B, C & D
Class II, Div 1 Groups E, F & G
Class III, Div 1
Excitation:
5-10 VDC (nominal).
Input Resistance:
> 2 K Ω.
Ex ia IIC; T4, Ta = 100°C
Class I, Zone 0
Output Resistance:
< 6 K Ω.
Operating
Temperature:
-54°C to +121°C (-65°F to +250°F).
For Reference Only – See Document #141576
Page 2 of 6
Compensated
Temperature:
+10°C to +93°C (+50°F to +200°F).
Connector:
MS3113H8-4P, 4-position male or
equivalent:
Transducer Cables
A = + Excitation
B = + Out
C = - Out
D = - Excitation
Proof Pressure:
2X Full Pressure Scale.
Burst Pressure:
3X Full Pressure Scale
Pressure Fitting:
1/4 - 18 NPT male.
Case Material:
316 Stainless Steel.
Insulation resistance:
> 50 M @ 50 VDC.
200131-05
0.5 metre (1.6 feet) cable.
200131-10
1 metre (3.3 feet) cable.
200131-15
1.5 metres (4.9 feet) cable.
200131-20
2 metres (6.6 feet) cable.
200131-40
4 metres (13.1 feet) cable.
200131-60
6 metres (19.7 feet) cable.
200131-90
9 metres (29.53 feet) cable
Pressure Transducer
200132-030
0-30 PSI SG
Ordering Information
200132-050
0-50 PSI SG
200130 Dual Pressure flexiTIM module
(all conduit bodies have 1-inch hubs).
200132-100
0-100 PSI SG
200130-AXX-BXX
200132-300
0-300 PSI SG
A: Conduit body style
-00
No conduit body
200132-500
0-500 PSI SG
-01
Appleton Style C body, Malleable Iron
-02
Appleton Style E body, Malleable Iron
-03
Appleton Style C body, Aluminum
-04
-05
Accessories
126709-04
Trendmaster 2000 Installation Guide
(flexiTIM™ installation guide is included)
Appleton Style E body, Aluminum
137230-01
flexiTIM™ installation Guide
Weatherproof housing mount
01620085
Extra terminal plugs for SPA line
connection. 3 terminal plugs provided
with each flexiTIMTM module.
-00
CSA, Class 1 DIV 2, no barriers
03814231
-01
CSA approvals installed with barriers
Compression fitting for 1-inch conduit
body hubs. Seals for cables when
installing flexiTIMTM modules without
conduit.
-02
CENELEC approvals installed with
barriers
04500006
Dow Corning 4, Electrical Insulating
Compound (5.3 Oz)
B: Approvals
 2001 Bently Nevada LLC
 used in this document are registered marks of Bently Nevada LLC
For Reference Only – See Document #141576
Page 3 of 6
Dimensional diagrams
134.6 (5.30)
122.9 (4.84)
CHANNEL B
R
CHANNEL A
106.5 (4.19)
46.0
(1.81)
Top
Powder Coated
Aluminum Housing
1/2-20 5 Pole
Female Receptacle
50.8
(2.00)
Side
*Allow 127 mm(5 in) for total Height
with connector and cable bend.
Gasket
2
16
8
4
64
32
128
EXAMPLE
CH A=12
CH B=13
SHIELD
RED
PWR
BLACK
COM
WHITE
SIG-
GREEN
SIG+
S
R
B
W
G
IN/OUT
S
R
B
W
G
IN/OUT
S R B WG
OFF
S
S R B WG
ON
S R B WG
CHANNEL A ADDRESS
ADD NUMBERS BELOW "ON" SWITCHES
CHANNEL B ADDRESS = CHANNEL A + 1
63.3 *
(2.49)
S
R
B
W
G
IN/OUT
Bottom
All dimensions are in millimeters (inches)
Figure 1: Dimensional diagram and wiring connection details
For Reference Only – See Document #141576
Page 4 of 6
Style C Conduit Body
Style E Conduit Body
Figure 2: Conduit Body Styles provided with the flexiTIM™ modules
Transducers
Transducer cables
with environmental boots
TM
FlexiTIM Module
Conduit body
Rigid conduit
SPA Line
Figure 3: Installed Pressure flexiTIM™ module
For Reference Only – See Document #141576
Page 5 of 6
MS3113H8-4P,
4-position male or equivalent:
A = + Excitation
B = + Out
A
D
C = - Out
D = - Excitation
C
B
1.00 [25.4]
0.85 [21.59]
29.21 [1.15]
22.00 [0.87]
6.86 [0.27]
1/4-18 NPT
Figure 4: Pressure Transducers
For Reference Only – See Document #141576
Page 6 of 6
A
D
B
C