D-01-07-02 - Dyna Power

advertisement
DYNA-POWER LUBRICATION
TECHNICAL BULLETIN D-01-07-02
Model: DP25-2000
Serial Number: 0012105
DYNA-POWER LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
fax: (708)389-9619
H-L
DP 25 CENTRAL STATION
Grizzly
A division of
Dyna-Power Engineers,Inc.
15330 Greenwood Ave
South Holland, IL 60473
JUNE 2003
TABLE OF CONTENTS:
I. Overview / General
Page No.
A. Ordering Information
1
B. Specifications
1
C. Operation
2
D. Overall Dimensions
2
II. Central Station Packages
A. DP25(E)-2000
3
B. DP25(E)-2010
3
C. DP25(E)-2001
4
D. DP25(E)-2011
4
E. DP25(E)-2100
5
F. DP25(E)-2101
5
G. DP25(E)-2111
6
III. Basic Installation
6-7
IV. Component Detail
A. Reservoir
8
B. Pump
9-11
C. Gear Reducer
11
D. Mounting Base
12
E. Hydraulic Reversing Valve
13-14
F. Electrical Reversing Valve
15
G. Timer
16-17
H. Mechanical Shut-Off
18
FOR CUSTOMER SERVICE & APPLICATION HELP:
Dyna-Power Engineers
15330 Greenwood Ave.
South Holland, IL 60473
ph: (708) 333-9300 fax: (708) 333-7092
1
DP 25 CENTRAL STATION
Overview:
General Specifications:
The Grizzly central station is a perfect midsize automatic lubricating station for heavy
industrial applications. The Grizzly is best
applied in single or dual systems that do
not exceed 100’ header length or exceed
150 lubrication points. The following bulletin
contains information pertaining to parts,
dimensional data, and ordering information
for the main system only. For information on
secondary parts and accessories, please
see their respective technical bulletins.
Pump Description:
Type: Motor driven, twin piston (uses
20:1 external gear reducer)
Capacity per Stroke: .06 cu.in.
Capacity per Minute: 5.13 cu.in.
Discharge Pressure: 3000 psi.
Reservoir Description:
Grease: 50 lbs. capacity
Material: Steel
Model: DP25-2000
Serial Number: 0012105
DYNA-POWER LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
fax: (708)389-9619
Motor Description:
1/3 h.p. @ 1750 rpm, 230/460VAC60HZ-3 phase. (Single phase available and DC motors available)
H-L
Reversing Valve:
DRV32-SL (std), DRV31-SL(pre-1999),
RVE1-DS1 (pre-2000), RVE2-DS1 (std)
Ordering Information
Station Packages
Part Number
Uses a hydraulically Uses an electrically Does not use a revoperated reversing operated reversing ersing valve.(For
sinlge line systems)
valve.
valve.
Standard System- Includes reversing valve, motor, and
low level switch in addition to reservoir, pump, gear reducer,
cover, bases, and requisite piping and fittings
Std.System w/Motor Starter- Includes above standard
system with main fuse disconnect switch, motor starter with
overload relay, control transformer 230/460VAC (primary),
115VAC (secondary) in a NEMA 12 enclosure.
DP25-2000 DP25E-2000 DP25S-2000
DP25-2010 DP25E-2010 DP25S-2010
Std.System w/Timer- Includes above standard system with
a timer and indicator lights which display:“Timing”,“Pumping”, DP25-2001 DP25E-2001 DP25S-2001
and “Fault. Also included is a reset/manual push button.
Std.System w/Timer and Motor Starter- Includes above
standard system, motor starter package, and timer package.
(see above packages for descriptions.)
DP25-2011 DP25E-2011 DP25S-2011
Std.System w/Bulk-Fill- Includes above standard system
with high-force solenoid shut-off valve (SVE2-SS1), mechanical shut-off valve, high-low level switch, pre-installed high
pressure hoses, and terminal box w/ seal-in relay (115VAC).
DP25-2100 DP25E-2100 DP25S-2100
Std.System w/Bulk-Fill and Timer - Includes above
standard system with the above bulk-fill and timer packages.
DP25-2101 DP25E-2101 DP25S-2101
Std.System Complete- Includes above standard system with
motor starter package, timer package, and bulk-fill package. DP25-2111 DP25E-2111 DP25S-2111
(see above packages for descriptions).
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
2
DP 25 CENTRAL STATION
Reservoir
Gear
Reducer
Relief
Line
Motor
Pressure
Setting
20
00
10
00
1500
30
00
500
2500
LL LL
LL
H-L
Cycle
Switch
Pump
Supply Line
Discharge Lines 1 & 2
Operation
The Grizzly pumping station consists of a twin piston pump, 20:1 gear reducer, 50lbs. steel reservoir with follower plate and indicator stem, reversing valve, and 1/3 h.p. motor in a NEMA 56 TEFC
frame.
The standard system begins when power is applied to the motor which, in turn, activates the pump.
In a dual line system, one line is pressurized by the pump while the second line relieves lubricant
back to the reservoir. During subsequent lubrication cycles, the pressurized line is relieved and
the relief line is pressurized. This alternate action is controlled by the reversing valve. The reversing valve, via a switch, sends the cycle information to the control (if applicable) which can be used
to set the cycle time. And it is the time set for the lubrication cycle, together with the measuring
valve settings that will determine the amount of lubricant that goes to each bearing.
Overall Dimensions
35.75
49.25 max
12.60
14.17
*All dimensions are in inches unless indicated
otherwise.
Model: DP25-2000
Serial Number: 0012105
DYNA-POWER LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
fax: (708)389-9619
H-L
3.54
19.69
26.77
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
3
DP 25 CENTRAL STATION
Standard Station Packages
Model: DP25(E)-2000 - Standard System
7
Item
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
LL LL
Motor
6
1
P25-JB
Juntion Box
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
12*
1
MG2-00-1002-1
Adapter
12
13*
1
DRV32-SL
Reversing Valve
13
14
1
P25-2300-1
Mounting Base
14
15
3
P080-6-8
Elbow
16
1
P115-6-8
Fitting
8
1
2
3
4
Model: DP25-2000
Serial Number: 0012105
er: 0012105
DYNA-POWER LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
LUBRICATION
fax: (708)389-9619
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
5
9
10
6
11
psi
kPa
H-L
16
15
* The following parts are not used for (E) electric reversing valve packages.
Model: DP25(E)-2010 - Standard System w/
Motor Starter / Disconnect Switch
Item
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
Motor
6
1
P25-JB
Juntion Box
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
9
12*
1
MG2-00-1002-1
Adapter
10
13*
1
DRV32-SL
Reversing Valve
14
1
P25-2300-1
Mounting Base
15
3
P080-6-8
Elbow
16
1
P115-6-8
Fitting
17
1
P25-2350-1
Mounting Frame
18
1
CC02-1001-1
M.S./D.S. Cabinet
Includes main fuse disconnect switch, motor starter with overload relay,
control transformer (230/460VAC-primary, 115VAC-secondary) in a NEMA
12 enclosure.
1
7
17
8
18
Model: DP25-2000
Serial Number: 0012105
DYNA-POWER LUBRICATION
er: 0012105
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
fax: (708)389-9619
LUBRICATION
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
5
11
H-L
12
13
14
6
4
3
2 16 15
* The following parts are not used for (E) electric reversing valve packages.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
4
Standard Station Packages
Item
Model: DP25(E)-2001 - Standard System w/Timer
Timer indicator lights display “Timing”, Pumping”, and “Fault”. Also included
is a manual/reset button.
1
7
8
17
PUMPING
TIMING
FAULT
POWER ON
18
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
Motor
6
1
--
Not Used
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
Model: DP25-2000
Serial Number: 0012105
er: 0012105
MANUAL
RESET
DYNA-POWER LUBRICATION
LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
ph: (708)389-7200
fax: (708)389-9619
5
9
12*
1
MG2-00-1002-1
Adapter
10
13*
1
DRV32-SL
Reversing Valve
11
14
1
P25-2300-1
Mounting Base
15
3
P080-6-8
Elbow
16
1
P115-6-8
Fitting
17
1
P25-2360-1
Mounting Frame
18
1
CC1-102-01T
Timer
12
H-L
13
14
4
3
2 16 15
* The following parts are not used for (E) electric reversing valve packages.
Model: DP25(E)-2011 - Standard System w/Timer and
Motor Starter / Disconnect Switch
1
7
Item
8
17
TIMING
PUMPING
FAULT
POWER ON
18
Model: DP25-2000
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
Motor
6
1
--
Not Used
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
Serial Number: 0012105
er: 0012105
DYNA-POWER LUBRICATION
LUBRICATION
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
fax: (708)389-9619
MANUAL
RESET
9
5
10
H-L
4
3
2 16 15
* The following parts are not used for (E) electric reversing valve packages.
12*
1
MG2-00-1002-1
Adapter
11
13*
1
DRV32-SL
Reversing Valve
12
14
1
P25-2300-1
Mounting Base
13
15
3
P080-6-8
Elbow
14
16
1
P115-6-8
Fitting
17
1
P25-2370-1
Mounting Frame
18
1
CC1-103-01T
Timer
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
5
Standard Station Packages
Item
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
Motor
6
1
CC1-101-01B
Junction Box
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
12*
1
MG2-00-1002-1
Adapter
13*
1
DRV32-SL
Reversing Valve
14
1
P25-2300-1
Mounting Base
15
3
P080-6-8
Elbow
13
16
1
P115-6-8
Fitting
14
17
1
DPLC7937-AC
Mech’l Shut-Off
18
1
MG-00-9001-1
Hose Assembly
* The following parts are not used for (E) electric reversing valve packages.
19
1
LSD4C1203
Switch
Model: DP25(E)-2101 - Standard System w/Bulk-Fill
and Timer
Item
Model: DP25(E)-2100 - Standard System w/Bulk-Fill
19
7
1
17
8
2
18
3
4
Model: DP25-2000
Serial Number: 0012105
er: 0012105
DYNA-POWER LUBRICATION
LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
fax: (708)389-9619
5
9
6
10
11
psi
kPa
12
H-L
16 15
18
1
19
7
8
17
TIMING
PUMPING
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
Motor
6
1
--
Not Used
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
FAULT
POWER ON
20
Model: DP25-2000
Serial Number: 0012105
er: 0012105
MANUAL
RESET
12*
1
MG2-00-1002-1
Adapter
9
13*
1
DRV32-SL
Reversing Valve
10
14
1
P25-2300-1
Mounting Base
11
15
3
P080-6-8
Elbow
12
16
1
P115-6-8
Fitting
13
17
1
P25-2360-1
Mounting Frame
14
18
1
LSD4C1203
Switch
19
1
DPLC7937-AC
Mech’l Shut-Off
20
1
CC1-102-01T
Timer
DYNA-POWER LUBRICATION
LUBRICATION
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
ph: (708)389-7200
fax: (708)389-9619
5
H-L
4
3
2 16 15
* The following parts are not used for (E) electric reversing valve packages.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
6
Standard Station Packages
Item
Model: DP25(E)-2111 - Standard System Complete
Consists of the standard system, motor starter/disconnect switch package, timer
package and bulk-fill package.
18
19
1
7
8
17
TIMING
PUMPING
Qty.
Part No.
Description
1
1
P25-1200-1
Reservoir ASM
2
1
P25-1181-1
Gear Reducer
3
1
DP25-CG
Coulping Guard
4
1
DP25-C100
Coupling
5
1
0620-3534
Motor
6
1
--
Not Used
7
1
DP25-143-1
Switch Cam
8
1
LSD4C2200
Low Level Switch
9
1
P25-1601-100
Pump ASM
10
1
P25-1650-1
Adapter Block
11*
1
D902D
Pressure Gauge
12*
1
MG2-00-1002-1
Adapter
13*
1
DRV32-SL
Reversing Valve
FAULT
POWER ON
20
Model: DP25-2000
Serial Number: 0012105
er: 0012105
DYNA-POWER LUBRICATION
LUBRICATION
-Power Engineers,Inc.
South Homan Ave.
Blue Island IL 60406
fax: (708)389-9619
A Div. of Dyna-Power Engineers,Inc.
12809 South Homan Ave.
Blue Island IL 60406
ph: (708)389-7200
fax: (708)389-9619
MANUAL
RESET
9
5
10
H-L
4
3
2 16 15
* The following parts are not used for (E) electric reversing valve packages.
14
1
P25-2300-1
Mounting Base
11
15
3
P080-6-8
Elbow
12
16
1
P115-6-8
Fitting
13
17
1
P25-2370-1
Mounting Frame
14
18
1
LSD4C1203
Switch
19
1
DPLC7937-AC
Mech’l Shut-Off
20
1
CC1-103-01T
Timer
Basic Installation
PRESSURE ADJUSTMENT
Fig.A
LIMIT SWITCH
(LSD4C1203)
The central station should be securely mounted on the floor or stable platform.
See page 7 for mounting dimenions.
psi
kPa
Pre-fill header and supply lines.
Air Bleed
Screw
Electrical connection to the motor may be necessary depending on the model.
In hydraulically reversed stations, connect discharge lines 1 & 2 using 3/8”
compression fittings. Then, using an appropriately sized screw driver, turn
the air bleed screw 1/4 turn counter-clockwise. After all the trapped air has
escaped, tighten the air bleed screw--turing the screw 1/4 clockwise. Now
wire the limit switch to the proper control. Then, using an appropriately
sized wrench, loosen the nut just below the pressure adjustment. Turn the
pressure adjustment to either raise or lower the pressure. Turning the pressure adjustment clockwise increases the pressure and turning it counterclowise decreases the pressure. After pressure has been adjusted, tighten
the lock nut. See Fig.A. DO NOT ADJUST WHILE SYSTEM IS UNDER
PRESSURE!
DISCHARGE PORT
(3/8”N.P.T.)
B
A
In electrically reversed stations, connect discharge lines 1 & 2 using 3/8”
compression fittings to ports A and B. See fig.B. Wire the reversing valve
to proper control, noting the wiring diagram found on page 15.
Fig.B
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
7
Standard Station Packages
Model: (E) Electrical Reversing Valve
1
H-L
2
3
3
Supply Line
Relief Line
3
Discharge Line
#1
Item
Qty.
Part No.
Description
1
1
RVE2-115
Reversing Valve
2
1
VE!-63
Subplate
3
4
P115-6-8
Fitting
3
Discharge Line
#2
Systems with electrical reversing valves do not rely on system
pressure to alternate between discharge lines directly. Pressure
switches should be purchased separately and wired to the main
control / timer.
PLC or remote operation is required.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
8
Reservoir Detail
9 10
8
7
Item
Qty
Part No.
1
1
DP25-140-1
Body
2
1
DP25-141-1
Cover
3
1
DP25-950-A
Oil Seal
4
1
DG1401
Plug
5
2
DP25-906-A
Screw
6
1
DP-142-1
Follower Rod
7
1
DP25-143-1
Switch Cam
8
2
DP25-907-A
Set Screw
9
1
DP25-909-A
Vent Screw
10
1
DP25-951
Ball
11
-
12
2
DP25-961-A
Hex Nut
13
1
DP25-142-A
Follower Plate
14
6
DP25-952-A
Bolt
15
1
DP25-143-A
Packing
16
6
DG3020
Lock Washer
17
6
DP25-962-A
Nut
18
1
DP25-144-A
Gasket
19
6
DP25-963-A
Bolt
20
6
DP25-970-A
Lock Washer
21
3
DG3022
Lock Washer
14
22
3
DP25-963-A
Hex Nut
16
23
1
LSD4C2200
Limit Switch
24
1
DP25-145-A
Plate
24
25
-
-
Not Used
15
26
-
-
Not Used
13
27
-
-
Not Used
28
-
-
Not Used
29
-
-
Not Used
30
3
DG2102
Bolt
31
1
MF-2910-1
Elbow
4
3
5
23
22
21
30
2
1
31
6
12
17
18
19
20
-
Description
Not Used
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
9
Pump Detail / Parts Breakdown
(Part Number: P25-1601-100)
The P25-1601-100 is a twin piston pump.
The motor, coupled to the crank shaft
rotates the eccenter, which in turn, alternatively
moves the pistons in and out of their respective
cylinders. This action draws the lubricant from
the reservoir and pushes it through the the
discharge ports. Back flow of lubricrant is
prevented by way of a check valve assembly
located in front of the cylinder.
1
Check Assembly
P/N: MP-5001-A
29
10 9 8 7 6 5
4
3
14
2
12
13
11
15
16
17
18
19
20
21
22
28
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
10
DP 25 CENTRAL STATION
Pump Detail / Parts Breakdown
26
27
H-L
23
Item
Qty.
Part No.
24 25
Description
Item
Qty.
Part No.
Description
1
2
DP25-203-A
Piston
18
1
DP25-946-A
Washer
2
2
DP25-440-A
O-Ring
19
1
DP25-169-A
Filter Screen
3
2
DP25-441-A
O-Ring
20
1
DP25-947-A
Washer
4
2
DP25-125-A
Cylinder
21
1
DP25-155-A
Plug
5-10
2
MP-5001-A
Check ASM
22
4
DG1501
Plug
11
2
DP25-930-A
Cover
23
1
DP25-984-A
Set Screw
12
4
DP25-944-A
Screw
24
1
DP25-156-A
Eccenter
13
4
DP25-945-A
Washer
25
1
DP25-954-A
Gasket
14
2
DP25-960-A
Shim
26
1
DP25-961-A
Plug
15
1
QHP4
Coupling (Check)
27
1
DP25-948-A
Washer
16
1
P010-4
Nipple
28
1
DP25-157-A
Housing
17
1
MP1102-A
Adapter
29
1
DP25-158-A
Yoke
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
11
Pump Dimensional Detail
8.35
C shaft
4.21
H-L
base
3.27
0.71
0.59
4.57
5.75
4.76
Gear Reducer Dimensional Detail - (P/N:P25-1181-1)
163.5mm
4- 12mm
154mm
150mm
88mm
0.984
0.709
12 mm
4 mm
13.5 mm
0m
79mm
m
16
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
12
DP 25 CENTRAL STATION
Mounting Base
(Part Number: P25-2300-1)
2- M6 Tap
0.8
1.0
4- 0.59
4- 0.43
12.6
4.57
2.36
3.27
19.69
3.5
26.8
1.2
1.2
1.0
2.0
4-
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
13
Parts Description
DRV32 - Hydraulic Reversing Valve
43
3.23
27 28
37 39
35
2.75
3.54
7.36
34
1.37
31
32
1.69
1.57
1.61
.55
1.65
5.74
.15
.39
2.28
3.14
3.93
7.95
Mounting bracket (p/n: RV0482)
2.95-3.38
36
29 30
7.08
4.71
0.4
0.4
0.4
3.54
.70
1.83
3.93
3.14
.98
2.16
44 45
46
47
.39
48 49
1.49
2.87
7.08
7.87
4.56
1.69
9/32 dia. 8 places
7.87
5.74
.98
13 gage
1.17
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
14
Parts Description
DRV32 - Hydraulic Reversing Valve
3
4
2
5
1 26 25 13 12
6
7
11
8
10
9
16
15
17
18
19
38
18
20 21
40
22
14 41 42 23
Item
Qty
Part No.
Description
Item
Qty.
Part No.
Description
1
1
RV0480
Body
26
9
DG3003
Washer
2
1
RV0467
Spring Holder
27
6
DG2001
Hex Screw
3
1
RV0474
Adj. Screw
28
6
DG3004
Lock Washer
4
1
RV0475
Lock Nut
29
4
DG2002
Hex Screw
5
1
RV0473
Spring
30
4
DG3005
Lock Washer
6
1
RV0476
Spring Shoe
31
1
RV0481
Cover Plate
7
1
RV0477
Link
32
1
DG4005
O-Ring
8
1
RV0478
Side Block
33
1
LSD4C 1203
Limit Switch
9
2
RV0472
Pilot Piston
34
2
DG2003
Screw
10
2
RV0471
Pilot Piston Plug
35
2
DG9004
Hex Nut
11
2
DG3001
Washer
36
1
RV0200
Bracket
12
1
DG4001
O-Ring
37
1
RV800124
Air Vent Screw
13
1
DG4002
O-Ring
38
1
RV800263
Hex Plug
14
1
RV0470
Main Piston
39
1
DG9005
Steel Ball
15
1
RV800264
Packing Gland
40
1
RV0479
Slipper Plate
16
2
DG3002
Washer
41
3
DG1002
Plug
17
1
RV800265
Screw
42
3
DG3006
Washer
18
1
RV800251
Switch Cam Rod
43
1
D902D
Pressure Gauge
19
1
DG9001
Switch Cam
44
1
RV0482
Bracket
20
1
DG4003
O-Ring
45
4
DG2004
Bolt
21
1
DG4004
Back-up Ring
46
4
DG3006
Washer
22
1
DG9002
Spring Pin
47
4
DG9007
Hex Nut
23
1
DG9003
Roll Pin
48
4
DG2001
Hex Screw
24
----
-----------
Not Used
49
4
DG3004
Lock Washer
25
9
DG1001
Plug
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
15
Parts Description
RVE2 - Electric Reversing Valve
RVE2-115
ELECTRICAL SPECIFICATIONS
RVE2
Model
Solenoid Voltage
115 V-AC
Coil Model
3.60
2.68
D-3BH-C1/C3
Applied Voltage
AC110
AC120
Frequency (HZ)
60
60
Starting Current (A)
4.6
5.0
Holding Current (A)
0.86
1.0
Holding Power (W)
34
42
4.29
1.42
2.76
4.71
4.71
9.43
Permissible Voltage
Range (V)
80 - 120
VE1-63
1 1/2
P
7/8
1 1/2
Wiring Diagram
1/2” NPT
2 5/8
3/8
Ground Terminal
3/8
Solenoid B Terminal
Indicating Light
1 15/16
Solenoid A Terminal
B
1 15/16
SOL B
A
11/16
SOL A
4 1/8
4 1/2
11/16
5/8
4 PLACES 13/32
4 PLACES
Common Jumper
3
1 1/2
7/8
Common Terminal
Ground Terminal
T
1/2” NPT
NOTE:
AC Coils are rated for both 50/60 Hz
(rewiring not required).
!
Do NOT supply electrical power to
the AC coils unless the coil is mounted
on the valve.
!
Do NOT exceed voltage specifications
shown here.
Electrical power should be maintained
on non-detented valves. Detent only
maintains start-up position of the valve.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
16
DP 25 CENTRAL STATION
Parts Description
Lube Guardian
Operator Interface Buttons
Change Preset:
Pressing this
button will bring up the “Preset
Screen”.
TIMING
PUMPING
FAULT
Data Field
Move Right
Message
Change Preset
Message: Pressing this button will
return the user back to the message
screen that is currently active.
Text Field
POWER ON
CHG
PRE
MSG
STAT
OPT
CLR
ENT
LUBETIME
FAULTIME
# CYCLES
0015
0008
0001
CHG
PRE
MSG
STAT
OPT
CLR
ENT
MANUAL
RESET
Move Left
Decrease
Increase
Enter
POWER ON
LUBETIME 0015 MIN
FAULTIME 0008 MIN
TOTAL CYCLES 0002
CHG
PRE
MSG
STAT
OPT
CLR
ENT
This default screen is displayed
when the system is powered up.
The ‘Lube Time’, ‘Faultime’, and
‘Total Cycles’ is displayed but the
the timer is not activated unless
the ‘Auto’ contact is closed or
jumpered.
Timing Message Screen
TIMING
LUBETIME 0015 MIN
ELPSTIME 0008 MIN
TOTAL CYCLES0002
POWER ON
LUBETIME 0015 MIN
FAULTIME 0008 MIN
TOTAL CYCLES 0002
CHG
PRE
MSG
STAT
OPT
CHG
PRE
MSG
CHG
PRE
MSG
OPT
STAT
OPT
CLR
ENT
CLR
ENT
This screen will display if the ‘Auto’
contact is closed or jumpered. The
preset ‘Lube Time’, the ‘Elapsed
Time’, and the preset number of
‘Cycles’ are indicated.
CLR
ENT
During normal operation, the operator
interface will display the power-up or
timing screen. Presets can not be
changed while the operator interface
is in this mode.
To Change Presets:
CHG
PRE
Press the
key to go to the
the ‘Change Preset’ screen. (In
order to change a particular setting,
the blinking cursor must be aligned
witt the desired preset menu line).
1
Timing Screen
TIMING
LUBETIME 0015 MIN
ELPSTIME 0008 MIN
TOTAL CYCLES0002
Pumping Message Screen
STAT
Preset Instructions
Power-up Default Screen
Increase /Decrease: These buttons
increase or decrease the values in
the data fields on the “Change
Preset” screen. Each push of the
button will either increase or decrease
the value by one. Larger changes in
values may made faster by use of
the left / right arrow keys.
Enter: Press this button to move the
cursor from the text field over to the
data field and back.
Operational Message Screens
Power-up Message Screen
Move Right /Left: These buttons
move the cursor either right or left
in the data field.
PUMP RUNNING
FAULTIME0001 MIN
# CYCLES CMP0001
This screen will display when the
‘Lube Time’ has expired and the
pump is activated. The ‘Faultime’
indicates the amount of fault time
that has elapsed. ‘# Cycles Cmpl’
indicates the number of cycles the
system has completed during the
current lubrication cycle.
Preset Screen
CHG
PRE
MSG
STAT
OPT
CLR
ENT
LUBETIME 0015
FAULTIME 0008
# CYCLES 0001
CHG
PRE
MSG
STAT
OPT
CLR
ENT
2 Press the
key to scroll the menu
up. Press this key until the cursor is at
the menu line to be changed.
5 To return to the default meassage screen
first press the
key to return the cursor
back to the left field and then
3 Press the
in the data field).
6 Press the
key. You should now be
back at the default message screen.
ENT
key. (The cursor is now
ENT
MSG
4 Press the
or the
key to adjust the numeric preset value up or down.
Once all the desired presets have been
made, return to the default message screen.
Instructions follow.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
DP 25 CENTRAL STATION
17
Parts Description
Lube Guardian contd.
Preset Instructions Contd.
Terms:
‘Lubetime’ is the interval between lubrication cycles.
‘Faultime’ is the time allowed for the system to reverse before it faults.
‘#Cycles’ sets the number of cycles of the reversing
valve during a pumping operation.
Fault Screens
Time-Out Fault Screen
FAULT TIMER
TIME-OUT
CHECK FOR LEAK
IN LINE #1 OR #2
Bulk Fill Alarm Screen
CHG
PRE
MSG
STAT
OPT
CLR
ENT
This screen will display when the
lube cycle (from one reversal to the
next) was not completed within the
set fault time. Check for the following:
- Broken pipes or leaking measuring valves.
ALARM
BULK FILL FAULT
Motor Overload Alarm Screen
CHG
PRE
MSG
STAT
OPT
CLR
ENT
This screen will display when the
low level switch on the grease reservoir does not change state (from
the N.C. position at low level to the
N.O. position after the bulk fill begins
refilling the reservoir).
- Reservoir level.
Check the bulk fill air pump and the
bulk fill solenoid valve.
- The motor and motor overload.
To reset the system, press the “Manual / Reset” push button.
To reset the system, press the “Manual / Reset” push button.
MOTOR
OVERLOAD
TRIP
CHG
PRE
MSG
STAT
OPT
CLR
ENT
This screen will display when a motor
overload occurs and the overload relay
trips. Check for the following:
- Binding in the pump and gear
reducer.
- Motor windings for shorts (single
phasing)
To reset the system, press the “Manual / Reset” push button.
Motor Starter Failure Alarm
MOTOR STARTER
DID NOT PULL IN
CHECK STARTER
COIL
CHG
PRE
MSG
STAT
OPT
CLR
ENT
This screen will display when the
motor starter does not pull in and
the feedback contact does not close.
Check for the following:
- PLC output Y06 and PLC input
X02.
- Motor starter coil for burn out.
To reset the system, press the “Manual / Reset” push button.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092
18
DP 25 CENTRAL STATION
Parts Description
DPLC7937-AC - Mechanical Shut-Off Valve
The mechanical shut-off valve is intended to be used as an
emergency shut-off of the grease bulk fill in the event that
the bulk-fill solenoid fails to shut-off the grease flow into the
reservoir.
4 1/2”
An optional microswitch (not shown) can be used for fault
indication.
DYNA-POWER LUBRICATION SOUTH HOLLAND IL PH:708.333.9300 FAX:708.333.7092