DIRECTIONAL MULTI-TAPS The signals from any (4) polarity DBS dish are required for multiple switches at multiple locations. SDMST416 SOLUTION SDMST412 Model SD MST416, SD MST412, SD MST409 and SD MST406 multiple input taps directionally couple a portion of trunk signals to feed single or groups of DBS switches. SDMST409 RELATED CONSIDERATIONS Amplifiers are required to increase the signal level from the dish to feed the taps. Model LAL204A-T includes automatic gain control for a constant input to the taps. The tap values are 16 dB, 12 dB, 9 dB and 6 dB. Model SD MST416 tap output is 16 dB less than the input SDMST406 DESCRIPTION SD MST4XX (4) INPUT TAPS S I T U AT I O N (4) coax, 54 to 2150 MHz DBS directional couplers. DC passive OUTPUT to INPUT. DC blocking at the tap port. F E AT U R E S SAT1 SAT2 SAT3 SAT4 • CATV / Ka/Ku bandwidth ........................... 5 to 2150 MHz • High Isolation adjacent input ............................... >40 dB ROOF • DC passing .............................................. Output to Input IN 1 IN 2 IN 3 IN 4 DC POL LOCK • DC blocking ......................................................... Tap Port OUT 1 OUT 2 OUT 3 OUT 4 • Die Cast case ............... (2) 10 AWG Green Ground screws DC PS DC SEQ409 -36/-42 dBm A P P L I C AT I O N N O T E S Model LAL204A amplifiers may be spaced at (5) floor increments when used with model SD MST416, SD MST412, SD MST409 and SD MST406 tap per floor. IN 1 FLOOR 5 IN 2 IN 3 IN 4 DC LAL204A OUT 1 OUT 2 OUT 3 OUT 4 PS 12 1000 DC -26/-20 dBm IN 1 IN 2 IN 3 IN 4 MST416 S 6 OUT 1 OUT 2 OUT 3 OUT 4 -42/-36 DBS Switch TO RECEIVERS 1 2 3 4 DBS Switch TO RECEIVERS 1 2 3 4 -28/-24 dBm The trunk level is indicated on the left and the tap level output is indicated on the right. The levels are at 250 MHz / 2150 MHz to indicate slope. IN 1 4 IN 2 IN 3 IN 4 MST412 S 2 OUT 1 OUT 2 OUT 3 OUT 4 -29/-27 dBm IN 1 3 IN 2 IN 3 IN 4 MST409 S 09 9 OUT 1 OUT 2 OUT 3 OUT 4 Automatic gain simplifies the design and the installation knowing that the amplifier output is -20 dBm when the LED lights are Green. -40/-36 -38/-36 -32/-34 dBm 2 IN 1 IN 2 IN 3 OUT 1 OUT 2 OUT 3 OUT 4 1 TO RECEIVERS 1 2 3 4 DBS Switch TO RECEIVERS 1 2 3 4 DBS Switch IN 4 MST406 S 06 6 DBS Switch -38/-40 TO RECEIVERS 1 2 3 4 DBS Switch TO RECEIVERS 1 2 3 4 DBS Switch TO RECEIVERS 1 2 3 4 DBS Switch TO RECEIVERS 1 2 3 4 COMMERCIAL / RETAIL Revised Feb 27 2014 Contact: Sonora Design Associates t 805.644.8913 t www.sonoradesign.com t info@sonoradesign.com SDMST4xx TAP SPECIFICATION 2 (4) Input Trunk Directional Coupler (TAP) 5 to 2150 MHz, 6 dB, 9 dB, 12 dB and 16 dB tap values Model Number Unit SD MST606 6 dB MDU Tap SD MST409 9 dB MDU Tap System Impedance ohm 75 Operating Frequency Range MHz Number of Input Ports Each (4) SCTE Indoor F , 1 inch spacing Each (4) SCTE Indoor F , 1 inch spacing Number of Output Ports dB > 40 dB Input / Output Return Loss dB > 12 (min) TAP Return Loss dB > 10 (min) Output Port to Tap Isolation dB 6 dB Tap 9 dB Tap Input to Tap Port Tap to Input Return Path 5 - 40 MHz Input to Output Port Input to Tap Port Tap to Input Return Path 5 - 40 MHz Input to Output Port 16 dB Tap 12 dB Tap Input to Tap Port Tap to Input Return Path 5 - 40 MHz Input to Output Port Input to Tap Port Tap to Input Return Path 5 - 40 MHz Environmental Requirements Operating Temperature range SD MST416 16 dB MDU Tap 5 to 2150 Isolation between ports DC Voltage Loss Output to Input DC Power Passing Output to Input only Insertion Loss (min & max over frequency & temperature range) Input to Output Port SD MST412 12 dB MDU Tap > 20 VDC 0.5 max mA 1000 (max.), Power passes from Trunk Output to Input dB Min ( 54 MHz) 3.5 ( 250 MHz) 3.5 Typical 5.0 Max (2150 MHz) 5.5 dB 6.8 6.8 6.7 7.2 dB 7.0 dB 2.0 2.0 3.5 4.0 dB 9.0 9.0 9.5 10.5 dB 9.5 dB 1.5 1.6 2.7 3.0 dB 11.8 11.8 12.5 13.2 dB 13.2 dB 0.8 0.9 1.2 2.0 dB 16.0 16.3 16.5 17.2 dB 17.2 Indoor or Lock Box (Note unit shall not be exposed to direct outdoor elements) ºC Humidity -40 to + 65 Shall survive 95% relative humidity over operating temperature Ground Screws Each 2 Green Screw Ground Points, per NEC 2008 version code 250.126, 10 gauge copper Mounting Tabs Inch (2) @ 6.25 center to center Dimensions L x W x H Inch 3.5 x 6.75 x 0.9 Weight Master Carton Quantity lb 0.9 Each 24 Revised Feb 27 2014 Contact: Sonora Design Associates t 805.644.8913 t www.sonoradesign.com t info@sonoradesign.com