Effective: March 2002 Alarm Signals Installation Data 75-008.A NOTE: All mounting plates and backboxes must be ordered separately. Select largest backbox shown in mounting options where possible to provide additional room for easy installation. (A) DBB BACKBOX Standard deep steel backbox provided with knockouts for interior surface mounting, concealed conduit mounting or semi-flush applications. It is painted to match the signal. (B) ISP SURFACE EXTENDER Use indoors. 51/4 sq. MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 AWG #12 8 8 8 8 4 5/32 3 45/64 29/32 3 45/64 25/32 4 5/32 (C) BB BACKBOX (D) SBB BACKBOX Standard steel backbox with knockouts for interior surface mounting, concealed conduit mounting or semi-flush applications. For surface mounting. MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 AWG #12 AWG #18 AWG #16 AWG #14 AWG #12 4 4 4 4 8 8 8 8 (E) WBB WEATHER RESISTANT BACKBOX Sturdy die cast housing, threaded conduit hole and knockout for outdoor applications. MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 AWG #12 4 4 4 4 (F) SFP SEMI-FLUSH PLATE Stamped aluminum surface wall plate which mounts behind the basic unit and serves to cover recessed backboxes in semi-flush mounting applications. (G) AP ADAPTER PLATE Stamped aluminum adapter plate designed for applications where semi-flush installation cannot be used. The plate can be mounted to standard octagon or round backboxes, single or double gang boxes or plastic rings. The backbox and basic unit are then fastened to the plate. This type mounting is referred to as a concealed conduit installation. (H) IOB BACKBOX For surface mounting. 6 5/16 3 3/8 6 #8-32 TAP (4) HOLES 3 3/8 MAXIMUM NUMBER OF CONDUCTORS (I) 4” SQUARE, DEEP, FLUSH (BO) AWG #18 AWG #16 AWG #14 AWG #12 8 8 8 8 (J) FSB1 FLUSH STROBE BACKBOX AND RP RETROFIT PLATE Special steel backbox with knockouts. FSB1 Flush Strobe box to be used with RP. MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 AWG #12 8 8 8 8 (L) 4” SQUARE, DEEP W/EXTENSION RING, FLUSH (BO) (K) DOUBLE-GANG, FLUSH (BO) 2-1/8” Deep 1-1/2” Deep 2-1/8”DEEP MAXIMUM NUMBER OF CONDUCTORS DEPTH AWG #18 AWG #16 AWG #14 AWG #12 4 4 4 4 MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 2-1/8" 8 8 8 AWG #12 8 1-1/2" 8 8 8 4 (N) SBL-2 SURFACE BACKBOX (M) SHBB SURFACE BACKBOX 1-11/16” 11/16” 6-7/64” 1.562 REF 3-3/8” KNOCKOUTS FOR 1/2” CONDUIT (EACH SIDE) 10-15/16” 3-3/8” (P) 4” SQUARE, FLUSH (BO) (O) SINGLE GANG, FLUSH (BO) 1-1/2” Deep 2” Deep MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 AWG #12 AWG #18 AWG #16 AWG #14 AWG #12 4 4 4 4 4 4 4 4 (R) WPSBB-R For surface mounting. (Q) DOUBLE-GANG, SURFACE (BO) For surface mounting. 4-3/4” 1-11/16” 1-3/4” 5-21/32” 3-3/8” TOP 4-3/4” 2-19/32” 5-3/16” MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS AWG #18 AWG #16 AWG #14 AWG #12 4 4 4 4 AWG #18 AWG #16 AWG #14 AWG #12 8 8 8 8 ORDERING INFORMATION M o d el N u mb er P a rt N u m b e r Ap p licatio n D escrip tio n D esig n atio n IOB-R 75-000000-001 MT, MT-WP, RSSWP Indoor/Outdoor Surface Backbox H ISP-R 75-000000-002 ET, ET70, MT Indoor Surface Plate B RP-R 75-000000-003 RSS, RSSP, 43T, MB, E70, ET70, MT, NS Retrofi t Plate (for use wi th i nstalled FSB1Box) J SBB-R 75-000000-004 RSS, RSSP, 43T, MB, E70, E90, ET70, MT, NS Surface Backbox D SFP-R 75-000000-005 RSS, RSSP, 43T, MB, E70, ET70, MT NS Semi -Flush Plate F BB-R 75-000000-006 RSS, RSSP, 43T, MB, NS Standard Indoor Backbox C AP-R 75-000000-007 43T, MB Concealed Condui t Plate G WBB-R 75-000000-008 43T, MB, RSSWP, MTWP, MT12/24 Weatherproof Backbox E DBB-R 75-000000-009 RSS, RSSP, 43T, MB, MT, NS Deep Indoor Backbox A SBL2-R 75-000000-012 RSS, RSSP, 43T, MB Surface Backbox N SHBB-R 75-000000-013 RSS, RSSP, 43T, MB, NS Surface Backbox M WPSBB 75-000000-014 RSSWP Weatherproof Backbox R Fenwal is a registered trademark of Kidde-Fenwal Inc. TM R Protection Systems KIDDE-FENWAL, INC. 400 MAIN STREET, ASHLAND, MA 01721 TEL: (508)881-2000 FAX: (508) 881-8920 www.fenwalfire.com This literature is provided for informational purposes only. KIDDE-FENWAL,INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 75-008.A 03/02 ©2002 Kidde-Fenwal, Inc. Printed in U.S.A.