Kesintisiz güç kaynakları teknik bilgilerini içeren PDF dosyasına

advertisement
RM-N SERIES (30-250 KVA)
KG
ÝRÝÞ GÜ Ç FAK
K
Ü
YÜ
T
ÖR
SE
TO
HI
GH
R
0.99
PO W
ON
FA
ER IN P UT
C
- LI N E V E R Ý M
INE
OD
I L G A R A N Ti
WARRAN
36
G
2Y
TY
2Y
U L A R D E SI
N
M
M
ÜL ER TASARI
M
OD
EN
E F FI CI
EA R
ON
-L
CY
%96
UPS, for the ones who seek for
zero risk. High-powered
modular UPS systems designed
for the loads without the
possibility of being turned-off.
These products, using the
latest means of power
electronic technology are
definitely unmatched.
Sýfýr risk isteyenlere özel UPS.
Kapatýlma ihtimali olmayan
yükler için tasarlanmýþ yüksek
güçlü modüler UPS sistemleri.
Güç elektroniði teknolojisinin
son imkanlarýný kullanan bu
ürünler kesinlikle rakipsiz.
RM-N SERIES (30-250 KVA)
TECHNICAL SPECIFICATIONS
MODEL
RM CABINET
RM-N Type
Cabinets
Size (WxYxH) mm
Maximum Power connector
Empty cabinet weight kg
RM 50
50 kVA
150 kVA
250 kVA
730x1650x780
910x1975x780
730x1975x780
250
TBA
190
Color
MODEL
RM-N
Modules
Front face: Black RAL9007 + Side covers: Graffiti gray
DPA MD 30-50 kVA
RM 30N
RM 40N
RM 50N
Output power - visible
30 kVA
40 kVA
50 kVA
Output power-active
24 kW
32 kW
40 kW
24 kVA/24kW
32 kVA/32kW
40 kVA/40kW
Output power (power factor=1)
Size (WxDxH) mm
Weight (UPS module) kg
663x225x720
50
57
Nominal input Voltage
3x380V/220V +N, 3x400V/230V +N, 3x415V/240V +N
Input Voltage Tolerance
3x306/177V - 3x464/264V range <100% load
3x280/162V - 3x464/264V range, 80% load
3x160/138V - 3x364/264V in the range of 60% load
35 - 70 Hz
Input Frequency
Input power factor
PF=0.99 (100% load)
Starting current
Limited to a soft start. (Max. In)
Input THDI
THD <3% (100% load)
Max input power (full load-full)
25 kW
33.7 kW
41.7 kW
Max input power (full load-empty)
28.2 kW
38 kW
45.8 kW
30-50
40-50
Number of battery (12V)
40-50
Max. battery charge current
10A standard (10A optional)
Battery Charge
Battery
IU (DIN 41773)
Standard (temperature sensor optional)
Temperature control
Battery test
Automatic and periodic (adjustable)
Battery Type
Output current
Output
Maintenance-free VRLA or NiCd
35 A
46.5 A
58 A
Output Voltage
3x380V/220V +N, 3x400V/230V +N, 3x415V/240V +N
Output Voltage Stability
Static <± 1%
Dynamic (loading from 0 to 100% or 100% to 0) <± 4%
Output Voltage pollution
The network was synchronized with <± 2%
(By-pass case) or <± 4%
Free work <± 4%
By-pass operation
Nominal input voltage <± 4%, or to phase 190-260V
100%
Permissible unbalanced load
125% load for 10 minutes - 150% load 60 seconds
Inverter overload operation
Inverter study 2xIn 250 ms - 10 ms 10xIn case of by-pass
Output short circuit current capacity of
3:1
Crest factor
Noise level (100%-50% load)
General
60
Front: RAL9007
Color
Input
RM 250
RM 150
55/51 dBA
63/53 dBA
Operating temperature
0 - 40 °C
Batteries for the ambient temperature
20 - 25 °C
Storage temperature
-25 - 70 °C
A low ambient temperature
Battery storage period
Maximum 6 months
Maximum operating altitude
<1000 m (Sea level)
Maximum 95% (natural environment)
Humidity
Rear section min. 20 cm (for the effective operation of the fans)
Placement
Input and input wiring
Efficiency AC-AC
Productivity economic mode
Below and ahead of
96%
95%
98%
37