Multi-Story Fittings

advertisement
Cast Iron Multi-Story
BR-CI-MS
APPLICATION GUIDE AND DIMENSIONAL CATALOG
Cast Iron Fitting Products for Multi-Story Applications
Revit® Drawings Available at www.charlottepipe.com
(Updated October 20, 2015)
© 2012-2015 Charlotte Pipe and Foundry Company
Multi-Story Fittings
TABLE OF CONTENTS............................................................................................................. PAGE
Anatomy of a Starter Fitting............................................................................................................. 3
Multi-Story Hubless Typical Installations.........................................................................................4-8
Multi-Story Hubless Fittings......................................................................................................... 9-11
Multi-Story Hubless Extended Fittings........................................................................................ 12-13
Multi-Story Hubless Fixture Fittings........................................................................................... 14-25
Multi-Story Hubless Starter Fittings...........................................................................................25-37
Hubless Application Index................................................................................................................ 38
EZS 700 and EZS 800 Minimum Space Requirements..................................................................... 39
Multi-Story Service Typical Installation............................................................................................40
Multi-Story Tapped Service Fittings............................................................................................ 41-42
Multi-Story Service Fixture Fittings............................................................................................43-48
Multi-Story Service Starter Fittings............................................................................................49-54
Service Weight Application Index..................................................................................................... 55
Minimum Space Requirements for Multi-Story Service Starter Fittings............................................. 56
Limited Warranty............................................................................................................................ 57
Download our Tech Tools App for
dimensional info, tech calculators
and more on your mobile device.
All detail drawings included in this manual can be downloaded as DWG or PDF documents at www.charlottepipe.com.
2
Multi-Story Fittings
Thank you for your interest in Charlotte Pipe and Foundry Starter Fittings. Charlotte Pipe and
Foundry offers both Hubless and Service fittings for multi-story applications. Our fittings have been
designed in cooperation with generations of commercial contractors to make commercial DWV installations more efficient.
Used in combination with thoughtful plumbing design, Starter Fittings will reduce the total number
of fittings in an installation. They reduce the number of joints, minimize the complexity of distributing
fittings on a job site, fit better within confined plumbing walls, and improve the overall quality of a job.
This maximizes profitability for the installing contractor. Another user-friendly feature of our Starter
Fittings is the ability to custom order vent and inlet positions to fit building needs.
Charlotte Pipe products are proudly manufactured in the USA. Please contact Charlotte Pipe with
any questions on the application of these fittings, comments or recommendations.
The Anatomy of a Starter Fitting
1 Fixture Fitting
+
Hubless Coupling
+
2 Sanitary Tee
+
Hubless Coupling
+
3Wye
+
Hubless Coupling
+
4Pipe
Equals
Revit® Drawings Available at www.charlottepipe.com
Charlotte Pipe and “You can't beat the system” are registered trademarks of Charlotte Pipe and Foundry Company.
3
Multi-Story Fittings
Multi-Story Hubless Fittings
TYPICAL HIGH-RISE BUILDING INSTALLATION
EZS 800 STACKED PERSPECTIVE
2” HUBLESS CAST IRON
PIPE VENT LINE
4” HUBLESS CAST IRON
PIPE DRAIN LINE
2” HUBLESS CAST IRON
FINISHED FLOOR
P-TRAP
(TYPICAL)
CONTRACTOR SHALL USE
PART NO. EZS 800R
2” HUBLESS CAST IRON
PIPE VENT LINE
CONTRACTOR SHALL USE
PART NO. EZS 7L
4” HUBLESS CAST IRON
PIPE DRAIN LINE
2” HUBLESS CAST IRON
FINISHED FLOOR
P-TRAP
(TYPICAL)
CONTRACTOR SHALL USE
PART NO. EZS 800R
2” HUBLESS CAST IRON
PIPE VENT LINE
CONTRACTOR SHALL USE
PART NO. EZS 7L
4” HUBLESS CAST IRON
PIPE DRAIN LINE
2” HUBLESS CAST IRON
FINISHED FLOOR
P-TRAP
(TYPICAL)
CONTRACTOR SHALL USE
PART NO. EZS 800R
All products manufactured by Charlotte Pipe and Foundry Company are proudly made in the U.S.A.
4
Multi-Story Fittings
Typical Installations
EZS 700D
DOUBLE FLOOR MOUNT BACK OUTLET APPLICATION
EZS 700R
WALL MOUNT BACK OUTLET APPLICATION
5
Multi-Story Fittings
Typical Installations
EZS 800D
DOUBLE FLOOR MOUNT BACK OUTLET APPLICATION
6
EZS 800R
WALL MOUNT BACK OUTLET APPLICATION
Multi-Story Fittings
Typical Installations
EZS 800D
DOUBLE WALL MOUNT BACK OUTLET APPLICATION
7
Multi-Story Fittings
Typical Installations
EZS 800L
FLOOR MOUNT BACK OUTLET APPLICATION
8
EZS 800R
FLOOR MOUNT BACK OUTLET APPLICATION
Multi-Story Fittings
Multi-Story Hubless Fittings
EZS 2” Vent Cross-Over
For use with EZS 50 through 800 Series Fittings
PART NO. EZS 7L
2” Vent Cross-Over
with Left Hand Inlet
PART NO. EZS 7
2” Vent Cross-Over, Plain
(No Outlets)
*U.P.C. No.
611942
04429
Size
2 x 183⁄8
A
47⁄8
C
93⁄16
F
Weight
183⁄8
8.1
PART NO. EZS 7D
2” Vent Cross-Over, Double
*U.P.C. No.
611942Size
04431 2 x 18 ⁄8
3
*U.P.C. No.
611942 Size
04430 2 x 183⁄8
A
47⁄8
B C
4 ⁄8 6 ⁄2 9 ⁄16
7
1
3
F
Weight
183⁄8 8.2
PART NO. EZS 7R
2” Vent Cross-Over
with Right Hand Inlet
(2 Inlets)
*U.P.C. No.
611942 Size
ABC
FWeight
61⁄2 93⁄16 183⁄8
A B C
47⁄8 61⁄2 93⁄16
FWeight
183⁄8
8.4
8.0
HOW TO DETERMINE RIGHT or LEFT HAND CROSS-OVER
With the vented end toward you, hold the fitting so that
you are looking into its length with the curved
side up. If the vent is on your left side, it is a
Left Hand fitting. If the vent is on your right
side, it is a Right Hand fitting.
(Right Hand Cross-Over Illustrated)
04432 2 x 183⁄8
Note: VENT CROSS-OVER
for use with EZS-50 through 800 Series fittings.
Specify Right, Left, Plain or Double.
Note: Our crossovers are designed for use with EZS
starter fittings, that is for the vent and stack centerline
to be 61 ⁄2”
9
Multi-Story Fittings
EZS 7R 2” Vent Cross-Over
VENT STACK
WALL HUNG LAVATORY
WALL HUNG LAVATORY
FINISHED FACE
OF WALL
WASTE STACK
CONTRACTOR SHALL USE
PART NO. EZS 7R
2” VENT CROSS-OVER WITH
RIGHT HAND INLET
FLOOR MOUNTED
BACK OUTLET TOILET
FLOOR MOUNTED
BACK OUTLET TOILET
CONTRACTOR SHALL USE
PART NO. EZS 38
CONTRACTOR SHALL USE
PART NO. EZS 800D
TUB
TUB
2” VENT CROSS-OVER FITTING RIGHT HAND
CONTRACTOR SHALL USE
PART NO. EZS 7R
2” VENT CROSS-OVER WITH
RIGHT HAND INLET
VENT STACK
RY
TO
VA
LA
RY
TO
VA
LA
WASTE STACK
T
ILE
TO
ILE
TO
T
B
TU
B
TU
2” VENT CROSS-OVER FITTING RIGHT HAND RISER DIAGRAM
10
Multi-Story Fittings
PART NO. EZS 9
P-Trap with 11⁄2” Tapped Side Inlet
Size
H
2
F
PART NO. EZS 38
Vented Tub Wye
Weight
53⁄1671⁄26.2
Size
G
PART NO. EZS 10
P-Trap with 2” Side Inlet
Size C
D
H
F Weight
2 91⁄251⁄4 159.4
2 2451⁄4291⁄213.7
PART NO. EZS 38L
Vented Tub Wye
Left Hand
J Weight
21 ⁄167 ⁄23 ⁄166.4
3
1
1
Size G
H
F Weight
29 ⁄23 ⁄4 1510.0
1
PART NO. EZS 13
45° Vented Tub Wye
Size E
F
G
3
PART NO. EZS 38R
Vented Tub Wye
Right Hand
Weight
2 1251 ⁄4153 ⁄410.1
Size G
H
F Weight
29 ⁄23 ⁄4159.0
1
3
11
Multi-Story Fittings
Multi-Story Hubless Extended Fittings
PART NO. EZS 14
Extended Short Sweep
Size
2 x 18
2 x 24
2 x 34
E
F
PART NO. EZS 16
2” x 24” Two-Way Sanitary Tee
Weight
61⁄2 188.0
61⁄2 2411.0
61⁄2 3413.9
PART NO. EZS 15
Extended Combination
Size
12
2 x 24
2 x 36
E
F
G Weight
63⁄16253⁄82412.0
63⁄1636 343⁄415.4
Size E
H
1
2 x 18
2 x 24
F Weight
4 ⁄24 ⁄2187.8
41⁄241⁄2 2410.4
1
PART NO. EZS 17
2” x 227⁄8” Extended Tapped Sanitary Tee
Size
H
F
Weight
2 x 1 ⁄2 x 22 ⁄83 ⁄422 ⁄89.6
2 x 2 x 227⁄833⁄4227⁄89.2
1
7
1
7
Multi-Story Fittings
PART NO. EZS 18
2” x 22 ⁄ ” Extended Tapped Sanitary Cross
PART NO. EZS 28
Sanitary Tapped Cross
7 8
Size
H
F
Weight
2 x 11⁄2 x 227⁄831⁄4227⁄810.0
2 x 2 x 227⁄833⁄4227⁄811.9
Size
PART NO. EZS 27
Sanitary Tapped Tee
2 x 11⁄2 x 31
2 x 2 x 31
F
Weight
E
13 16
F
3
G
1
H
Weight
1
111⁄43112.6
111⁄43113.6
PART NO. NH 27
Tapped Double Wye
Size
Weight
2 x 1 ⁄22 ⁄ 9 ⁄44 ⁄23 ⁄44.8
1
H
F
111⁄4 3115.0
111⁄4 3115.0
PART NO. EZS 35B
Double Vertical Sanitary Tapped Tee
Size
Size
H
2 x 11⁄2 x 31
2 x 2 x 31
D
F
Testing with or use of compressed air or gas in Cast Iron
pipe or fittings can result in explosive failures and cause
severe injury or death.
Weight
2 x 11⁄251⁄1665 ⁄85.6
• NEVER test with or transport/store
compressed air or gas in Cast Iron pipe
or fittings.
• NEVER test Cast Iron pipe or fittings
with compressed air or gas.
• ONLY use Cast Iron pipe and fittings
for drain, waste and vent or sanitary
sewer applications.
13
Multi-Story Fittings
Multi-Story Hubless Fixture Fittings
PART NO. NH 502
4” No Hub Prison Fitting with 2” Top Vent
(Designed for use above the floor; Baffle helps prevent passage of contraband between cells.)
Part No.
NH 502
NH 502
NH 502
NH 502
14
Size
4 Less Tap
4 With Tap
4x3 Less Tap
4x3 With Tap
UPC# 611942-
A
00639
00640
11119
11120
8
8
8
8
C
F
5 ⁄4 12
51⁄4 12
51⁄4 12
51⁄4 12
1
G
Weight
820.3
820.8
823.4
823.4
Multi-Story Fittings
PART NO. NH 502
Detail Drawing
4” No Hub Prison Fitting with 2” Top Vent and 2” 45° Tap Service for Two Cells at 45° Angle
15
Multi-Story Fittings
PART NO. EZS 6*
Figure Six
PART NO. EZS 8*
Figure Eight
(Double, Left Hand or Right Hand; Designed for use
below the floor; Double fitting has a baffle)
(Double, Left Hand or Right Hand; Designed for use
below the floor; Double fitting has a baffle)
(Photos Show Double)
(Photos Show Left Hand)
Part No.
Size
C
D
E
1
9
1
F
H
Weight
EZS 6D** 3x2
EZS 6D** 4x2
4 ⁄87 ⁄165 ⁄16113 ⁄1613.0
N
41⁄29 61⁄213 423.1
N
EZS 6L
EZS 6L
3x2
4x2
41⁄879⁄1651⁄161137⁄1611.4
N
1
1
4 ⁄29 6 ⁄213 418.0
N
EZS 6R
EZS 6R
3x2
4x2
4 ⁄87 ⁄165 ⁄16113 ⁄1611.4
N
41⁄29 61⁄213 418.0
N
1
9
1
7
7
*When ordering please specify Double, Left or Right.
** Double fitting has a baffle.
N = non-stock item – contact customer service for availability.
16
Part No.
Size
C
D
E
1
9
1
F
H
Weight
EZS 8D**3x2
4 ⁄87 ⁄165 ⁄16113 ⁄1613.0
N
EZS 8L 3x2
EZS 8L 4x2
41⁄879⁄1651⁄161137⁄1612.5
N
41⁄29 61⁄213 419.8
N
EZS 8R 3x2
EZS 8R 4x2
41⁄879⁄1651⁄161137⁄1612.5
N
1
1
4 ⁄29 6 ⁄213 419.8
N
7
*When ordering please specify Double, Left or Right.
** Double fitting has a baffle.
Multi-Story Fittings
PART NO. EZS 6D
Detail Drawing
4x2 Vented Closet Tee - Right Hand with 2” Top Vent
5-1/2”
MIN.
FINISHED FACE
OF WALL
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 4” WASTE PIPING
(ALSO AVAILABLE FOR 3” STACK SIZE)
INTEGRAL 2” VENT STACK FITTING
OPPOSITE SIDE
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
CLOSET FLANGE
FINISHED FLOOR
10-1/2” CONTRACTOR SHALL USE
CLOSET FLANGE
PART NO. EZS 6D
NO-HUB STARTER FITTING
DOUBLE FITTING RIGHT HAND UNDER-SLAB - LEFT SIDE ELEVATION
VERTICLE CONFIGURATION
17
Multi-Story Fittings
PART NO. EZS 8D
Detail Drawing
3x2 Double Figure 8 Fitting with 2” Vent
5-1/2”
MIN.
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 2” VENT PIPING
FINISHED FACE
OF WALL
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
FINISHED FLOOR
CLOSET FLANGE
CLOSET FLANGE
INTEGRAL 2” VENT
STACK FITTING
10-1/2”
CONTRACTOR SHALL USE
PART NO. EZS 8D
NO-HUB STARTER FITTING
9”
DOUBLE FITTING UNDER-SLAB - LEFT SIDE ELEVATION
HORIZONTAL CONFIGURATION
18
Multi-Story Fittings
PART NO. EZS 8L
Detail Drawing
Vented Closet Tee - Left Hand with 2” Side Inlet
5-1/2”
MIN.
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 4” WASTE PIPING
FINISHED FACE
OF WALL
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
FINISHED FLOOR
CONTRACTOR SHALL USE
13” PART NO. EZS 8L
NO-HUB STARTER FITTING
CLOSET FLANGE
INTEGRAL 2” INLET LEFT SIDE
SINGLE FITTING LEFT HAND UNDER-SLAB - LEFT SIDE ELEVATION
19
Multi-Story Fittings
PART NO. EZS 50
10” Closet Fittings with 2” Inlet
PART NO. EZS 51
10” Closet Fittings with 2” Inlet and 2” Side Inlet
(Double, Left Hand or Right Hand; Designed for use
below the floor; Fitting does not have a baffle)
(Double, Left Hand or Right Hand; Designed for use
below the floor; Fitting does not have a baffle)
(Photos Show Left Hand)
(Photos Show Left Hand)
UPC#
Part No.
Size
611942-
EZS 50D
EZS 50L
EZS 50R
20
4
4
4
A
B
C
D
F
Weight
04484 10 ⁄46 ⁄23 ⁄4 44 ⁄215.0
04476 103⁄461⁄233⁄4 441⁄212.3
04477 103⁄461⁄233⁄4 441⁄212.2
3
1
3
1
UPC#
Part No.
Size 611942-
EZS
A
B
C
D
E
F
Weight
51D 4 04424 10 ⁄46 ⁄2349 ⁄24 ⁄215.0
EZS 51L 4 04425 103⁄461⁄23491⁄241⁄212.8
EZS 51R 4 04473 103⁄461⁄23491⁄241⁄212.6
3
1
1
1
Multi-Story Fittings
PART NO. NH 457
Vented Closet Tee with 2” Top Vent
PART NO. NH 463
Vented Closet Cross with 2” Top Vent
(Left Hand or Right Hand; Designed for use below the floor;
Fitting does not require a baffle)
(Designed for use below the floor; Fitting has a baffle)
(Photos Show Left Hand)
(Gray Area
Indicates Baffle)
Size
B C D E F G
Wt.
4x4x2x4(L) 41⁄451⁄433⁄44101⁄233⁄412.1
4x4x2x4(R) 41⁄451⁄433⁄44101⁄233⁄411.6
Size
4x4x2x4x4
B C D EF G
Wt
41⁄451⁄433⁄44101⁄233⁄415.0
Double fittings are equipped with Baffles to
prevent blowback on back-to-back installations
of back-outlet toilets.
21
Multi-Story Fittings
PART NO. NH 463
Detail Drawing - 4x4x2x4x4 Vented Closet Cross with 2” Top Vent
5-1/2”
MIN.
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 4” WASTE PIPING
FINISHED FACE
OF WALL
INTEGRAL 2” VENT STACK FITTING
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
10-1/2”
FINISHED FLOOR
CONTRACTOR SHALL USE
PART NO. NH 463
NO-HUB STARTER FITTING
CLOSET FLANGE
CLOSET FLANGE
CLOSET BEND PER
REQUIREMENTS
CLOSET BEND PER
REQUIREMENTS
DOUBLE FITTING UNDER-SLAB - LEFT SIDE ELEVATION
PART NO. NH 463
Baffle Detail Drawing - 4x4x2x4x4 Vented Closet Cross with 2” Top Vent
INTEGRAL 2” VENT STACK FITTING
INTEGRAL
BAFFLE
FLOW
SOLID BAFFLE INTEGRALLY CAST
IN CENTER OF FITTING
FLOW
FLOW
BAFFLE ON DOUBLE FITTING
FOR BACK TO BACK WATER
CLOSET INSTALLATIONS.
LEFT SIDE SECTION
22
10-1/2”
CONTRACTOR SHALL USE
PART NO. NH 463
NO-HUB STARTER FITTING
FRONT OR BACK SIDE ELEVATION
Multi-Story Fittings
PART NO. NH 458
Vented Closet Tee with 2” Top Vent and 2” Side Inlet
(Left Hand or Right Hand; Designed for use below the floor; Fitting does not require a baffle)
(Photos Show Left Hand)
Size
A B C D EF
G Wt.
4x4x2x2x4(L) 81⁄841⁄4 51⁄471⁄2 4 101⁄2 33⁄4 12.3
4x4x2x2x4(R) 81⁄841⁄4 51⁄471⁄2 4 101⁄2 33⁄4 12.2
ORDERING EZS CLOSET FITTINGS
SERIES 50, 100, 400, 700,800
These No-Hub closet fittings can be ordered with Left hand, Right hand or Double closet inlets, and with 2” sanitary inlets at various heights
on either side of the fitting. They can be ordered with an additional inlet (see illustrations) by adding a “1” after the first digit of the Series
Number, i.e. 51, 110, 210, etc.
To order, show the above information as follows:
EZS
Enter Series
Number here
00 or 10
M
Enter L (Left),
R (Right) or
D (Double) here
B
Enter height of
sanitary Inlet “M”
or 0 if not required
Enter height of
sanitary Inlet “B”
or 0 if not required
Example: If you were ordering a Left hand Series 100 fitting with one sanitary inlet at 13” on the “B” side of the fitting, you would write
EZS 100
L M 0 B 13
or with the extra inlet,
EZS 110
L M 0 B 13
M & B dimensions must be measured from the bottom of the fitting.
23
Multi-Story Fittings
PART NO. NH 458
Detail Drawing
4x4x2x2x4 Vented Closet Tee/Left Hand with 2” Top Vent and 2” Side Inlet
5-1/2”
MIN.
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 4” WASTE PIPING
FINISHED FACE
OF WALL
INTEGRAL 2” VENT STACK FITTING
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
10-1/2”
CONTRACTOR SHALL USE
PART NO. NH 458
NO-HUB STARTER FITTING
FINISHED FLOOR
CLOSET FLANGE
CLOSET BEND PER REQUIREMENTS
INTEGRAL 2” INLET LEFT SIDE
SINGLE FITTING LEFT HAND UNDER-SLAB - LEFT SIDE ELEVATION
24
Multi-Story Fittings
Multi-Story Hubless Starter Fittings
PART NO. NH 464
Vented Closet Cross with 2” Top Vent
and 2” Side Inlet
PART NO. EZS 100*
16” Closet Fittings with 2” Inlets
(Designed for use below the floor; Fitting has a baffle)
(Double, Left Hand or Right Hand;
Designed for use below the floor)
(Photos Show Left Hand)
(Gray Area
Indicates Baffle)
Size
A B C DEF
G Wt.
4x4x2x2x4x4 8 ⁄84 ⁄4 5 ⁄47 ⁄2 4 10 ⁄2 33⁄4 15.6
1
1
1
1
1
M & B dimensions must be
measured from the bottom
of the fitting.
Part No.
Size
A
B
C
D
E
1
1
1
M Weight
EZS 100D4x16 16 ⁄454 ⁄26 ⁄25 ⁄2 522.0
N
3
HOW TO DETERMINE RIGHT or LEFT HAND
CLOSET FITTING
To determine if whether a closet fitting is a
right hand or left hand configuration, stand
the fitting up with the closet inlet facing you.
If the opening is on your left, it is a Left Hand
fitting. If the opening is on your right, it is a Right
Hand fitting. Right Hand and Left Hand configurations do not
apply for Double fittings.
(Right Hand Closet Fitting Illustrated)
EZS 100L4x16163⁄4541⁄261⁄251⁄2 520.0
N
EZS 100R4x16 163⁄4541⁄261⁄251⁄2 521.1
N
*When ordering please specify Double, Left or Right.
N = non-stock item – contact customer service for availability.
25
Multi-Story Fittings
PART NO. EZS 400*
30” Closet Fittings with 2” Inlet
(Double, Left Hand or Right Hand; Designed for use in the floor)
(Photos Show
Left Hand)
Part No.Size
AB CD EM
Weight
4x30
4x30
4x30
4x30
4x30
4x30
4x30
4x30
4x30
4x30
4x30
30
30
30
30
30
30
30
30
30
30
30
0 41 ⁄261 ⁄251 ⁄2034.0N
6 ⁄241⁄261⁄251⁄2034.2N
12 41⁄261⁄251⁄2037.8N
261⁄241⁄261⁄251⁄2034.3N
0 41⁄261⁄251⁄2434.0N
261⁄241⁄261⁄251⁄2434.0N
0 41⁄261⁄251⁄261⁄233.1 N
61⁄241⁄261⁄251⁄261⁄234.0 N
261⁄241⁄261⁄251⁄261⁄236.8 N
0 41⁄261⁄251⁄21231.0N
261⁄241⁄261⁄251⁄21230.0N
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
EZS 400R 4x30
30
30
30
30
30
30
30
30
30
30
30
0 41⁄261⁄251⁄2032.9N
6 ⁄241⁄261⁄251⁄2034.5N
12 41⁄261⁄251⁄2037.1N
261⁄241⁄261⁄251⁄2033.8N
0 41⁄261⁄251⁄2434.0N
261⁄241⁄261⁄251⁄2428.9N
0 41⁄261⁄251⁄261⁄233.9 N
61⁄241⁄261⁄251⁄261⁄235.4 N
261⁄241⁄261⁄251⁄261⁄235.4 N
0 41⁄261⁄251⁄21231.0N
261⁄241⁄261⁄251⁄21228.5N
EZS 400D 4x30
EZS 400D 4x30
EZS 400D 4x30
EZS 400D 4x30
EZS 400D 4x30
EZS 400D 4x30
EZS 400D 4x30
EZS 400D 4x30
30 0 41⁄261⁄251⁄2029.3N
30 61⁄241⁄261⁄251⁄2036.4N
30 12 41⁄261⁄251⁄2039.6N
30 0 41⁄261⁄251⁄2438.0N
30 0 41⁄261⁄251⁄261⁄235.6 N
30 261⁄241⁄261⁄251⁄261⁄238.9 N
30 0 41⁄261⁄251⁄21235.7N
30 261⁄241⁄261⁄251⁄21238.0N
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
EZS 400L
1
1
*When ordering please specify Double, Left or Right.
M & B dimensions must be
measured from the bottom
of the fitting.
N = non-stock item – contact customer service for availability.
26
Multi-Story Fittings
PART NO. EZS 400D
Detail Drawing
4x30 Closet Fitting Double - M Inlet 0 B Inlet 61⁄2”
5-1/2”
MIN.
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 4” WASTE PIPING
FINISHED FACE
OF WALL
INTEGRAL 2” VENT STACK FITTING
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
FINISHED FLOOR
SLAB
30”
SLAB
CLOSET FLANGE
CLOSET BEND
PER REQUIREMENTS
CONTRACTOR SHALL USE
PART NO. EZS 400D 4x30
CLOSET FITTING DOUBLE M INLET 0
B INLET 6-1/2”
CLOSET FLANGE
CLOSET BEND PER REQUIREMENTS
INTEGRAL 2” INLET RIGHT SIDE
DOUBLE FITTING IN-SLAB - LEFT SIDE ELEVATION
27
Multi-Story Fittings
PART NO. EZS 700
Threaded Starter Fitting with or without 2” No-Hub Inlets
(Double, Left Hand or Right Hand; Designed for use above the floor with back-outlet water closets; Double starter fittings have a baffle)
(Photo Shows Left Hand)
(Photo Shows Left
Hand, Top View)
FLOOR/CEILING
(Photo Shows Double, Top View)
A & B Dimensions must be
measured from the top
of the fitting.
Part No. Size ABCDE
Weight
EZS 700D** 4x28
EZS 700D** 4x28
EZS 700D** 4x28
0
0
51⁄22861⁄240.0
1
0
8 ⁄251⁄22861⁄242.0
231⁄281⁄251⁄22861⁄242.0
EZS 700L
EZS 700L
EZS 700L
EZS 700L
4x28
0
0 51⁄22861⁄234.6
4x28
0 81⁄251⁄22861⁄235.7
4x28 14 81⁄251⁄22861⁄236.3
4x28 231⁄281⁄251⁄22861⁄232.0
EZS 700R
EZS 700R
EZS 700R
EZS 700R
4x28
4x28
4x28
4x28
0
0 51⁄22861⁄230.0
0
81⁄251⁄22861⁄234.0
14 81⁄251⁄22861⁄235.3
231⁄281⁄251⁄22861⁄232.0
**Double starter fitting has a baffle.
28
Multi-Story Fittings
PART NO. EZS 700R
Detail Drawing
4x28 Threaded Right Hand - A Inlet 0; B Inlet 0
with EZS 23 Trim Package
29
Multi-Story Fittings
PART NO. EZS 700D
Detail Drawing
4x28 Threaded Double - A Inlet 0; B Inlet 81⁄2”
with EZS 22 Support Frame and EZS 24 Trim Package
30
Multi-Story Fittings
PART NO. EZS 800
Threaded Starter Fitting with or without 2” No-Hub Inlets
(Double, Left Hand or Right Hand; Designed for use above the floor with back-outlet water closets; Double starter fittings have a baffle)
(Photo Shows Right Hand)
(Photo Shows Right
Hand, Top View)
FLOOR/CEILING
(Photo Shows Double, Top View)
A & B Dimensions must be
measured from the top
of the fitting.
Part No.
Size
A
B
C
D
E
Weight
EZS 800D** 4x28
EZS 800D** 4x28
16
16
0
5 ⁄2286 ⁄242.0
81⁄251⁄22861⁄242.0
EZS 800L
EZS 800L
4x28
4x28
16
16
0 51⁄22861⁄235.4
81⁄251⁄22861⁄236.3
EZS 800R
EZS 800R
4x28
4x28
16
16
0 51⁄22861⁄235.6
81⁄251⁄22861⁄235.3
1
1
**Double starter fitting has a baffle.
Note: “O” dimension denotes the absence of the designated inlet.
31
Multi-Story Fittings
PART NO. EZS 800L
Detail Drawing
4x28 Threaded Left Hand - A Inlet 16; B Inlet 0
with EZS 22 Support Frame and EZS 24 Trim Package
32
Multi-Story Fittings
PART NO. EZS 800D
Detail Drawing
4x28 Threaded Double - A Inlet 16; B Inlet 0
with EZS 23 Trim Package
33
Multi-Story Fittings
PART NO. EZS 710
No-Hub Starter Fitting with or without 2” No-Hub Inlets
PART NO. EZS 810
No-Hub Starter Fitting with or without 2” No-Hub Inlets
(Double, Left Hand or Right Hand; Designed for use above the
floor with back-outlet water closets; Double starter
fittings have a baffle)
(Double, Left Hand or Right Hand; Designed for use above the
floor with back-outlet water closets; Double starter
fittings have a baffle)
(Photo Shows Left Hand)
(Photo Shows Left
Hand, Top View)
(Photo Shows Left Hand)
(Photo Shows Double, Top View)
(Photo Shows Double, Top View)
FLOOR/CEILING
FLOOR/CEILING
A & B Dimensions must be
measured from the top
of the fitting.
A & B Dimensions must be
measured from the top
of the fitting.
Part No.
Size
EZS 710D** 4x28
EZS 710D** 4x28
EZS 710D** 4x28
A
B
C
D
E
Weight
0
0
5 ⁄2 284 43.0
0
81⁄251⁄2 284 43.0
231⁄281⁄251⁄2 284 43.0
1
EZS 710L
EZS 710L
EZS 710L
EZS 710L
4x28
0
0 5 ⁄2 284 36.6
4x28
0
81⁄251⁄2 284 36.6
4x28 14 81⁄251⁄2 284 36.6
4x28 231⁄281⁄251⁄2 284 36.6
EZS 710R
EZS 710R
EZS 710R
EZS 710R
4x28
0
0
51⁄2 284 36.6
4x28
0
81⁄251⁄2 284 36.6
4x28 14 81⁄251⁄2 284 36.6
4x28 231⁄281⁄251⁄2 284 36.6
1
**Double starter fitting has a baffle.
34
(Photo Shows Left
Hand, Top View)
Part No.
Size
EZS 810D** 4x28
EZS 810D** 4x28
A
16
16
B
C
D
E
Weight
0
5 ⁄2286 ⁄243.0
81⁄251⁄22861⁄243.0
1
1
EZS 810L
EZS 810L
4x28 16 0 51⁄22861⁄236.6
4x28 16 81⁄251⁄22861⁄236.6
EZS 810R
EZS 810R
4x28
4x28
16
16
0
51⁄22861⁄236.6
1
8 ⁄251⁄22861⁄236.6
**Double starter fitting has a baffle.
Note: “O” dimension denotes the absence of the designated inlet.
Multi-Story Fittings
PART NO. EZS 22
Trim Package, Support Frame Assembly
(Weight capacity for the EZS 22 Support Frame is 500 pounds maximum.)
1—FRAME
1—LEFT LEG
1—RIGHT LEG
1—SUPPORT LEG (used for single only)
5—1⁄2 ” x 11⁄4 ” BOLTS
5—1⁄2 ” FLAT WASHERS
(Illustration Shows Front of Frame)
(Illustration Shows Side of Frame)
(Illustration Shows Front of Frame)
(Illustration Shows
Front View)
EZS 22 Extended Leg
(Left or Right)
(Illustration Shows
Side View)
EZS 22 Support Leg
(Illustration Shows
Side View)
35
Multi-Story Fittings
PART NO. EZS 24
Trim Package, Wall-Hung Back-Outlet Assembly
(To be used with PART NO. EZS 22 Support Frame Assembly)
1—4” PVC Sch. 80 NIPPLE with TEST CAP
1—BOWL GASKET
4—5⁄8 ” x 12” RODS
4—5⁄8 ” CHROME CAP NUTS
8—5⁄8 ” JAM NUTS
4—5⁄8 ” FLAT WASHERS
4—5⁄8 ” FIBER WASHERS
3—3⁄8 ” x 11⁄2 ” BOLTS FOR FACEPLATE
3—3⁄8 ” FLAT WASHERS
4—5⁄8 ” STAR WASHERS
EZS 22 and EZS 24 Installation Instructions
Exploded View of Support
Assembly Hardware
1.Identify
the major components of the EZS 24 Trim
Package and EZS 22 Support Frame.
2.Secure EZS 22 Support Frame to installed starter fitting
using 3⁄8” x 1 ½” bolts and 3⁄8” flat washers.
3.Secure right and left legs to the EZS 22 faceplate using
½” x 1 ¼” bolts and ½” flat washers in position shown
to the right.
4.Adjust assembly to the desired height.
Level and align
the assembly.
5.Secure
the feet of the EZS 22 Support Frame to the
floor using the ½” x 1 ¼” bolts supplied.
6.Secure
support leg. For double starter fittings, the
support leg is not required.
7.Secure
⁄8” x 12” EZS 24 thread rods to faceplate
according to EZS 22 faceplate.
5
8.Install EZS 24 threaded nipple to the EZS 700 or EZS
800 fitting.
36
EZS 22 and EZS 24 Assemblies Illustrated
Multi-Story Fittings
PART NO. EZS 23
Trim Package, Floor-Mounted Back-Outlet Assembly
(Note: Not to be used with PART NO. EZS 22 Support Frame Assembly)
1—4” PVC Sch. 80 NIPPLE with TEST CAP
1—BOWL GASKET
2—5⁄16 ” x 12” RODS
2—5⁄16 ” HEX NUTS
2—5⁄16 ” FLAT WASHERS
2—5⁄16 ” CAP NUTS
PART NO. EZS 800D
Typical Installation
NH 28
EZS 7L
EZS 16
NH 4
Long
Vent
NH 34
18
42
EZS 14
EZS 38
EZS 800D
NH 12
EZS 9
37
Multi-Story Fittings
Hubless Application Index
Fixture Type
CPF Fitting
Support Frame
(If Applicable)
Wall Hung, Back Outlet
EZS 700
EZS 22
EZS 800
EZS 22
Starter Fitting is designed to be
installed with inlet above floor level
Floor Mounted, Back Outlet
EZS 700
EZS 710
Starter Fitting is designed to be
installed with inlet above floor level
EZS 800
EZS 810
Floor Mounted, Bottom Outlet
EZS 6
EZS 8
Starter Fitting is designed to be
EZS
50
installed with inlet either in or
EZS 51
below floor level
EZS 100
EZS 400
EZS 457
EZS 458
EZS 463
EZS 464
38
Trim Package
(If Applicable)
EZS 24
EZS 24
EZS 23
EZS 23
EZS 23
EZS 23
Multi-Story Fittings
Minimum Space Requirements for EZS 700 and EZS 800 Starter Fittings installed with
EZS 22 Support Frame and EZS 24 Trim Package.
(Note: EZS 22 Support Frame Assembly is not compatible with EZS 23 Trim Package.)
EZS 700 and EZS 800 Double Starter Fittings
EZS 700 and EZS 800 Left and Right Starter Fittings
7 3 /4”
11”
Part No.
Size
A
B
C
D
E
Weight
EZS 700D 4x28 0
0 51⁄2 2861⁄240.0
EZS 700D 4x28 0 81⁄251⁄2 2861⁄242.0
EZS 700D 4x28 231⁄281⁄251⁄2 2861⁄242.0
EZS 800D 4x28
EZS 800D 4x28
16
16
0 51⁄2 2861⁄242.0
81⁄251⁄2 2861⁄242.0
Part No.
Size
A
B
C
D
E
Weight
EZS 700L
EZS 700L
EZS 700L
EZS 700L
4x28 0
0 51⁄2 2861⁄234.6
4x28 0 81⁄251⁄2 2861⁄235.7
4x28 14 81⁄251⁄2 2861⁄236.3
4x28 231⁄281⁄251⁄2 2861⁄232.0
EZS 700R
EZS 700R
EZS 700R
EZS 700R
4x28 0
0 51⁄2 2861⁄230.0
4x28 0 81⁄251⁄2 2861⁄234.0
4x28 14 81⁄251⁄2 2861⁄235.3
4x28 231⁄281⁄251⁄2 2861⁄232.0
EZS 800L 4x28
EZS 800L 4x28
16
16
0 51⁄2 2861⁄235.4
81⁄251⁄2 2861⁄236.3
EZS 800R 4x28
EZS 800R 4x28
16
16
0 51⁄2 2861⁄235.6
81⁄251⁄2 2861⁄235.3
39
Multi-Story Fittings
Multi-Story Service Fittings
Typical installation shows single back-outlet water closet and double-sink applications.
MULTI-STORY INSTALLATION
➀ SV 1739 Left Hand Vented Closet Tee
with 2” 45° Taps
➁ SV 1801 2x2x2 Tapped Harp Fitting
③ SV 83 5x2 Straight Tapped Tee
④ 5x10 SV Single Hub Pipe
➄ 4x10 SV Single Hub Pipe
SV 206 4x4x18 Tapped Closet Bend
with Southern Code Brass Plug
MULTI-STORY INSTALLATION
➀ SV 581 4x2x2 Double Sink Stack — 1770
➁ SV 83 3x2 Straight Tapped Tee
③ 3x10 Single Hub Pipe
④ 4x10 Single Hub Pipe
All products manufactured by Charlotte
Pipe and Foundry Company are proudly
made in the U.S.A.
40
Multi-Story Fittings
Multi-Story Tapped Service Fittings
PART NO. SV 83
Straight Tapped Tee
Size
E’
G
PART NO. SV 89
Long Sanitary Tapped Tee
X
Weight
2 x 11⁄22 61⁄48 5.5
2 x 2
2
61⁄48 6.0
3 x 11⁄221⁄27 9 7.4
3 x 2
21⁄27 9 8.5
4 x 2
3
7
9
12.3
4 x 3
4
8
11
14.0
4 x 4
3
7
9
15.0
5 x 2
31⁄27 9 13.5
5 x 4
31⁄281⁄21217.9
6 x 4
41⁄49 1324.4
PART NO. SV 84
Sanitary Tapped Tee
Size
2 x 2 x 18
E’
G
X
Weight
3 ⁄166 ⁄418 8.8
1
1
PART NO. SV 91
Sanitary Tapped Cross
Size
E’
G
X
2 x 11⁄2213⁄1661⁄4
2 x 2
31⁄1661⁄4
3 x 2
39⁄167
4 x 2
41⁄167
Weight
86.4
86.7
9 9.0
911.6
PART NO. SV 206
Tapped Closet Bend with
Southern Code Brass Plug
Size
E’
G
X
Weight
2 x 11⁄2213⁄1661⁄4 86.0
2 x 2
31⁄1661⁄4 85.8
3 x 11⁄235⁄167 9 8.0
3 x 2
39⁄167 9 8.1
4 x 11⁄2313⁄167 9 10.3
4 x 2
41⁄16
7
9
11.7
4 x 3
41⁄16 8 1113.6
Size
31⁄2 x 4 x 4 x 18
A
18
BWeight
4
17.4
41
Multi-Story Fittings
PART NO. SV 985
Tapped Bath Vent Wye
PART NO. SV 566
Tapped Long Sweep Tee
Size
A
2 x 2
B
C
D
Weight
51⁄231⁄8455⁄86.2
PART NO. SV 982
Tapped By-Pass Vent Fitting
(Side View)
Size
2 x 2
(Top View)
Size
2 x 2
42
A
18
B
10
C
D
E
F
Weight
61⁄231⁄23 51⁄411.3
A
B
C
D
Weight
41⁄165 31⁄421⁄28.4
HOW TO DETERMINE RIGHT or LEFT HAND
CLOSET FITTING
To determine if whether a closet fitting is a
right hand or left hand configuration, stand
the fitting up with the closet inlet facing you.
If the opening is on your left, it is a Left Hand
fitting. If the opening is on your right, it is a Right
Hand fitting. Right Hand and Left Hand configurations do not
apply for Double fittings.
(Right Hand Closet Fitting Illustrated)
Multi-Story Fittings
Multi-Story Service Fixture Fittings
PART NO. SV 458
Vented Closet Tee with 2” Top Vent
and 2” Extended Side Inlet
PART NO. SV 459D
Vented Closet Cross with 2” Top Vent
and 2” Extended Side Inlet
(Right Hand or Left Hand; Designed for use below the floor;
Fitting does not require a baffle)
(Designed for use below the floor;
Fitting does not have a baffle)
(Photo Shows Right Hand)
Size
4x4x2x2x4 RH
4x4x2x2x4 LH
(Photo Shows Right Hand,
Top View)
A B
11
11
C
D
EWeight
41⁄253⁄1649⁄1643⁄1637.0
41⁄253⁄1649⁄1643⁄1637.8
PART NO. SV 460
Vented Closet Tee with 2” Top Vent
(Right Hand or Left Hand; Designed for use below the floor;
Fitting does not require a baffle)
(Photo Shows Left Hand)
Size
4 x 4 x 2 x 4 RH
4 x 4 x 2 x 4 LH
4 x 4 x 2 x 2 x 4
A B
11
CWeight
61⁄443⁄447.0
PART NO. SV 463D
Vented Closet Cross with 2” Top Vent
and 2” Extended Side Inlet
(Designed for use below the floor;
Fitting does not have a baffle)
(Photo Shows Left Hand,
Top View)
A B
11
11
Size
C Weight
4 ⁄25 ⁄1635.0
41⁄253⁄1635.0
1
3
Size
4 x 4 x 2
A
11
B
C
Weight
6 ⁄44 ⁄443.8
1
3
43
Multi-Story Fittings
PART NO. SV 581
Double Sink Stack-1770
PART NO. SV 581
Double Sink Stack-1770
(Designed for use above the floor)
(Designed for use above the floor)
3x2x2
4x2x2
(Photo Shows Top View)
Size
3 x 2 x 2
44
A
B
(Photo Shows Top View)
Weight
Size
123⁄441⁄265⁄841⁄253⁄418.0
C
D
E
4 x 2 x 2
A
B
C
D
Weight
121⁄2 571⁄241⁄221.4
Multi-Story Fittings
PART NO. SV 581
Double Sink Stack Fitting
(Designed for use above the floor)
4x2x2
WASTE STACK
DISPOSAL
VENT
SINK VENT
VENT STACK
COUNTERTOP
DOUBLE BOWL
SINK
CONTRACTOR SHALL USE
PART NO. SV 900 GASKET
OR OPTIONAL LEAD & OAKUM
P-TRAP
(TYPICAL)
IN WALL WASTE
CONTRACTOR SHALL USE
PART NO. SV 581
DISPOSAL
FINISHED FLOOR
DOUBLE SINK STACK FITTING - FRONT ELEVATION
45
Multi-Story Fittings
PART NO. SV 1739R
Right Hand Vented Closet
Tee with 2” 45° Taps
PART NO. SV 1739L
Left Hand Vented Closet
Tee with 2” 45° Taps
(Designed for use above the floor)
(Designed for use above the floor)
(Photo Shows Top View)
(Photo Shows Top View)
2” Tap
Size
AB CD E F GWeight
4 x 2 x 4 x 2 18 63⁄4 81⁄4 45⁄8 35⁄8 41⁄2 23⁄451.1
46
Size
2” Tap
AB CD E F GWeight
4 x 2 x 4 x 2 18 63⁄4 81⁄4 45⁄8 35⁄8 41⁄2 23⁄451.0
Multi-Story Fittings
PART NO. SV 1739D
Vented Closet Cross
with 2” 45° Taps
PART NO. SV 1801
2x2x2
Tapped Harp Fitting
(Designed for use above the floor)
2” Tap
(Photo Shows
Top View)
2” Tap
2” Tap
2” Tap
Size
AB CD E F GWeight
4 x 2 x 4 x 2 18 63⁄4 81⁄4 45⁄8 35⁄8 41⁄2 23⁄457.5
Size
2 x 2 x 2
A
B
C
Weight
117⁄162 35⁄815.5
47
Multi-Story Fittings
PART NO. SV 1739L with SV 1801
SV 1739L Left Hand Vented Closet Tee with SV 1801 Harp Fitting
Use with Floor Mounted Bottom Outlet Water Closet
CONTRACTOR SHALL USE
PART NO. SV 83
CONTRACTOR SHALL USE
PART NO. SV 1801
4” SV CAST
IRON PIPE
VENT LINE
LAVATORY
2” THREADED
COPPER OR
STEEL PIPE
4” SV CAST IRON
PIPE DRAIN LINE
TUB
FINISHED
FLOOR
CONTRACTOR SHALL USE PART NO. SV 206
TAPPED CLOSET BEND WITH SOUTHERN
CODE BRASS PLUG
CONTRACTOR SHALL USE
PART NO. SV 1739L VENTED
CLOSET TEE WITH 2” 45° TAPS
FRONT ELEVATION
48
P-TRAP
(TYPICAL)
Multi-Story Fittings
Multi-Story Service Starter Fittings
PART NO. SV 973R
Right Hand Starter Fitting with 4” Tap and
2” Tapped “A” Side Inlet
PART NO. SV 973L
Left Hand Starter Fitting with 4” Tap and
2” Tapped “A” Side Inlet
(Designed for use above the floor
with back-outlet water closets)
(Designed for use above the floor
with back-outlet water closets)
(Photo Shows Top View)
(Photo Shows Top View)
INLET
A
6 1⁄2
9 1⁄2
INLET
A
6 1⁄2
9 1⁄2
NOTES:
1. Single Vertical
R.H. Offset Back
Outlet Starter Fitting
2.4”Stack with 2”Vent
& Inlets
3. Face Plate Package
Not Included
Size Inlet
A
B
C
D
E
NOTES:
1. Single Vertical
L.H. Offset Back
Outlet Starter Fitting
2.4”Stack with 2”Vent
& Inlets
3. Face Plate Package
Not Included
F
X
Weight
4 61⁄2 See Chart 61⁄24 41⁄16442534.8
4 91⁄2 See Chart 61⁄24 41⁄16442534.4
Size
Inlet
A
BCD EFXWeight
4 61⁄2 See Chart 61⁄244 442539.2
4 91⁄2 See Chart 61⁄244 442539.0
49
Multi-Story Fittings
PART NO. SV 974R
Right Hand Starter Fitting with 4” Hub and
2” Tapped “A” Side Inlet
PART NO. SV 974L
Left Hand Starter Fitting with 4” Hub and
2” Tapped “A” Side Inlet
(Designed for use above or in the floor
with back-outlet or bottom-outlet water closets)
(Designed for use above or in the floor
with back-outlet or bottom-outlet water closets)
(Photo Shows Top View)
(Photo Shows Top View)
INLET
A
6 1⁄2
Size
ABC DE
FX
Weight
4 with A inlets 61⁄261⁄261⁄241⁄164 425 39.2
50
INLET
A
6 1⁄2
Size
ABC DE
FX
Weight
4 with A inlets 61⁄261⁄261⁄2 4 441⁄1625 39.7
Multi-Story Fittings
PART NO. SV 974R
Right Hand Starter Fitting with 4” Hub and
2” Tapped “A” and “B” Side Inlets
PART NO. SV 974L
Left Hand Starter Fitting with 4” Hub and
2” Tapped “A” and “B” Side Inlets
(Designed for use above or in the floor
with back-outlet or bottom-outlet water closets)
(Designed for use above or in the floor
with back-outlet or bottom-outlet water closets)
FLOOR/CEILING
Size
4 with A & B inlets
FLOOR/CEILING
NOTES:
1. Single Vertical
R.H. Offset
Floor Starter
Fitting
2.4” Stack with
2” Vent & Inlets
3. Face Plate
Package Not
Included
NOTES:
1. Single Vertical
R.H. Offset
Floor Starter
Fitting
2.4” Stack with
2” Vent & Inlets
3. Face Plate
Package Not
Included
INLET
A B
61⁄218
INLET
A B
61⁄218
A B C
D XWeight
61⁄218 61⁄261⁄2 2546.2
Size
4 with A & B inlets
A B C
D XWeight
61⁄218 61⁄261⁄22543.7
51
Multi-Story Fittings
PART NO. SV 974R with SV 900 CHARLOTTE SEAL GASKET
14-1/2”
MIN.
FINISHED FACE
OF WALL
HIDDEN LINE INDICATES
EXTENSION OF 4” WASTE PIPING
FINISHED FACE
OF WALL
INTEGRAL 2” VENT STACK FITTING
CONTRACTOR SHALL USE
PART NO. SV 900 GASKET
FLOOR MOUNTED
BOTTOM OUTLET
TOILET FIXTURE
FINISHED FLOOR
25”
CONTRACTOR SHALL USE
PART NO. SV 974R
HUB STARTER FITTING
FLANGE
4” PIPE
5/16” THREADED ROD - (TAP IN FITTING)
INTEGRAL 2” THREADED INLET (BOTH SIDES)
RIGHT HAND FITTING - LEFT SIDE ELEVATION
52
Multi-Story Fittings
PART NO. SV 975
Double Starter Fitting with 4” Tap and
2” Tapped “A” Side Inlets
(Designed for use above the floor with back-outlet
water closets; Fitting has a baffle)
Cast Iron pipe and fittings are only intended for DWV
(drain, waste and vent) non-pressure applications. Using
cast iron pipe and fittings in pressure applications could
result in explosive failures, causing serious injury or death
or property damage.
(Gray Area
Indicates Baffle)
(Photo Shows Top View)
Testing with or use of compressed air or gas in Cast Iron
pipe or fittings can result in explosive failures and cause
severe injury or death.
• NEVER test with or transport/store
compressed air or gas in Cast Iron pipe
or fittings.
• NEVER test Cast Iron pipe or fittings
with compressed air or gas.
• ONLY use Cast Iron pipe and fittings
for drain, waste and vent or sanitary
sewer applications.
Unsecured piping can fall and cause serious injury. Always
properly support and secure piping to help prevent injury.
Always wear protective clothing, including hard hats,
during installation.
INLET
A
9 1⁄2
Size
4
A
B
C
D
E
F
X
Weight
9 ⁄26 ⁄24444 ⁄162542.5
1
1
1
53
Multi-Story Fittings
PART NO. SV 976
Double Starter Fitting with 4” Hub and
2” Tapped “A” Side Inlet
PART NO. SV 976
Double Starter Fitting with 4” Hub and
2” Tapped “A” and “B” Side Inlets
(Designed for use above or in the floor with back-outlet or
bottom-outlet water closets; Fitting has a baffle)
(Designed for use above or in the floor with back-outlet or
bottom-outlet water closets; Fitting has a baffle)
(Gray Area
Indicates Baffle)
(Photo Shows Top View)
(Gray Area
Indicates Baffle)
INLET
A B
61⁄218
INLET
A
6 1⁄2
Size
A B C D E F
XWeight
4 with A inlets 61⁄261⁄261⁄24 4 41⁄162550.8
54
Size
A B C D E XWeight
4 with A & B inlets 61⁄21861⁄261⁄241⁄1625 56.6
Multi-Story Fittings
Service Weight Application Index
Fixture Type
CPF Fitting
Wall Hung, Back Outlet
Starter Fitting is designed to be
installed with inlet above floor level
Floor Mounted, Back Outlet
Starter Fitting is designed to be
installed with inlet above floor level
Floor Mounted, Bottom Outlet
Starter Fitting is designed to be
installed with inlet either in or below floor level
SV 973
SV 975
Support Frame
(If Applicable)
Trim Package
(If Applicable)
EZS 22
EZS 22
EZS 24
EZS 24
SV 974
SV 976
SV 581
SV 1739
SV 458
SV 459D
SV 460
SV 463D
SV 1739
55
Multi-Story Fittings
Minimum Space Requirements for Multi-Story Service Starter Fittings
Tapped Service Fitting Illustrations Shown with EZS 22 Support Frame and EZS 24 Trim Package
11”
16”
PART NO. SV 973R Right Hand Starter Fitting with 4” Tap
PART NO. SV 975 Double Starter Fitting with 4” Tap
Size Inlet
Size
A
B
C
D
E
F
X
Weight
4 6 ⁄2 See Chart 6 ⁄24 4 ⁄16442534.8
4 91⁄2 See Chart 61⁄24 41⁄16442534.4
1
1
1
4
A
A
1
C
D
E
F
X
Weight
1
13 1 /2”
PART NO. SV 973L Left Hand Starter Fitting with 4” Tap
Size
Inlet
B
9 ⁄26 ⁄24444 ⁄162542.5
1
BCD EFXWeight
4 61⁄2 See Chart 61⁄244 442539.2
4 91⁄2 See Chart 61⁄244 442539.0
21”
PART NO. SV 974R*
Right Hand Starter Fitting with 4” Hub and A Inlets
Size
ABC DE
FX
Weight
4 with A inlets 61⁄261⁄261⁄241⁄164 425 39.2
PART NO. SV 974L
Left Hand Starter Fitting with 4” Hub and A Inlets
PART NO. SV 976*
Double Starter Fitting with 4” Hub and A & B Inlets
PART NO. SV 974R
Right Hand Starter Fitting with 4” Hub and A & B Inlets
Size
A B C D E XWeight
4 with A & B inlets 61⁄21861⁄261⁄241⁄1625 56.6
PART NO. SV 976
Double Starter Fitting with 4” Hub and A Inlet
Size
A B C D E F
1
1
XWeight
1
*Above the floor installation for floor-mounted, back-outlet
fixtures shown. Fitting can also be installed in the floor for floormounted, bottom-outlet water closets.
56
ABC DE
FX
Weight
Size
4 with A & B inlets
4 with A inlets 6 ⁄26 ⁄26 ⁄24 4 4 ⁄162550.8
1
Size
4 with A inlets 61⁄261⁄261⁄2 4 441⁄1625 39.7
A B C
D XWeight
61⁄218 61⁄261⁄2 2546.2
PART NO. SV 974L
Left Hand Starter Fitting with 4” Hub and A & B Inlets
Size
4 with A & B inlets
A B C
D XWeight
61⁄218 61⁄261⁄22543.7
Multi-Story Fittings
Limited Warranty
Charlotte Pipe and Foundry Company® (Charlotte Pipe®)
Products are warranted to be free from manufacturing defects
and to conform to currently applicable ASTM standards for a
period of five (5) years from date of delivery. Buyer’s remedy
for breach of this warranty is limited to replacement of, or
credit for, the defective product. This warranty excludes any
expense for removal or reinstallation of any defective product
and any other incidental, consequential, or punitive damages.
This limited warranty is the only warranty made by seller
and is expressly in lieu of all other warranties, express
and implied, including any warranties of merchantability
and fitness for a particular purpose. No statement, conduct
or description by Charlotte Pipe or its representative, in
addition to or beyond this Limited Warranty, shall constitute
a warranty. This Limited Warranty may only be modified in
writing signed by an officer of Charlotte Pipe.
7) The Products fail due to the freezing of water in the
Products.
8) The Products fail due to contact with chemical agents,
fire stopping materials, thread sealant, plasticized vinyl
products, or other aggressive chemical agents that are
not compatible.
9) Pipe outlets, sound attenuation systems or other devices
are permanently attached to the surface of Charlotte®
PVC, ABS or CPVC products with solvent cement or
adhesive glue.
This Limited Warranty will not apply if:
Charlotte Pipe products are manufactured to the applicable
ASTM or CISPI standard. Charlotte Pipe and Foundry
cannot accept responsibility for the performance, dimensional
accuracy, or compatibility of pipe, fittings, gaskets, or
couplings not manufactured or sold by Charlotte Pipe and
Foundry.
1) The Products are used for purposes other than their
intended purpose as defined by local plumbing and building
codes, and the applicable ASTM standard.
Any Charlotte Pipe products alleged to be defective must be
made available to Charlotte Pipe at the following address for
verification, inspection and determination of cause:
2) The Products are not installed in good and workmanlike
manner consistent with normal industry standards;
installed in compliance with the latest instructions
published by Charlotte Pipe and good plumbing practices;
and installed in conformance with all applicable plumbing,
fire and building code requirements.
Charlotte Pipe and Foundry Company
Attention: Technical Services
2109 Randolph Road
Charlotte, North Carolina 28207
3) This limited warranty does not apply when the products
of Charlotte Pipe are used with the products of other
manufacturers that do not meet the applicable ASTM or
CISPI standards or that are not marked in a manner to
indicate the entity that manufactured them.
4) In hubless cast iron installations, this warranty will not
apply if products are joined with unshielded hubless
couplings. Charlotte Pipe requires that its hubless cast
iron pipe and fittings be joined only with shielded hubless
couplings manufactured in accordance with CISPI 310,
ASTM C 1277 and certified by NSF® International or
with Heavy Duty Couplings meeting ASTM C 1540.
5) The Products fail due to defects or deficiencies in design,
engineering, or installation of the piping system of which
they are a part.
6) The Products have been the subject of modification;
misuse; misapplication; improper maintenance or repair;
damage caused by the fault or negligence of anyone other
than Charlotte Pipe; or any other act or event beyond the
control of Charlotte Pipe.
Purchaser must obtain a return materials authorization
and instructions for return shipment to Charlotte Pipe of any
product claimed defective or shipped in error.Any Charlotte
Pipe product proved to be defective in manufacture will be
replaced F.O.B. point of original delivery, or credit will be
issued, at the discretion of Charlotte Pipe.
4/24/15
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC / Cast Iron pipe or fittings can result in explosive
failures and cause severe injury or death.
• NEVER test with or transport/store
compressed air or gas in PVC / ABS /
CPVC / Cast Iron pipe or fittings.
• NEVER test PVC / ABS / CPVC / Cast
Iron pipe or fittings with compressed
air or gas, or air over water boosters.
• ONLY use PVC / ABS / CPVC / Cast Iron
pipe or fittings for water or approved
chemicals.
• Refer to warnings on PPFA’s website
and ASTM D 1785.
Charlotte and Charlotte Pipe are registered trademarks of Charlotte Pipe and Foundry Company.
PO Box 35430
Charlotte, NC 28235 USA 704/348-6450 800/572-4199
www.charlottepipe.com
FAX 800/553-1605
57
Multi-Story Fittings
Notes
58
Multi-Story Fittings
Notes
59
PO BOX 35430
CHARLOTTE
NORTH CAROLINA 28235
PHONE
(704) 348-6450
(800) 438-6091
FAX
(800) 553-1605
LITERATURE BY FAX (800) 745-9382
WWW.CHARLOTTEPIPE.COM
All products manufactured by
Charlotte Pipe and Foundry Company
are proudly made in the U.S.A.
Download