HORIZONTAL DUCT EVAPORATOR COIL CE3A Features The CE3A coil is available in 6 sizes, 2 through 5 ton. The CE3A was specially developed for use with remote condensing units. Optimum refrigerant-to-air heat transfer is built into the design through a tight bond between mechanically expanded 3/8-in. grooved copper tubing and aluminum fins. All model sizes use the Check-Flo-Rater metering device. Casing is fully insulated to minimize losses. All units have sweat connections from the coil. Inside the casing, the coil sets in a coated drain pan which has 3/4-in. connections. AIRFLOW A91037 Form No. PDS CE3A.24.1B MODEL NUMBER NOMENCLATURE C E A 3 A 018 018, 1-1/2 Ton 024, 2 Ton 030, 2-1/2 Ton Etc. C—Coil A—Cap Tube, Uncased, A-Coil B—Cap Tube, Cased, A-Coil C—Piston, Uncased, A-Coil D—Piston, Cased, A-Coil E—Piston, Cased, Slab F—Mobile Home, Uncased, A-Coil A—Standard C—Compact W—Wide DENT LAB OR MANUFACTUR ER TY FE FOR P U B LI C A SA EQ RI CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. NING ITIO ND ST G AIR CO Y YING WITH PL OM Y TE ® IN T IFIED O ARI A RT S C CE UNIT AR EN AN EP Major Series change OR AT IN D 3—Horizontal 5—Upflow/Downflow UIP M E NT STA NDARD 21 0 5/8" (16) TYP. "A" "E" TYP. "B" 12" (305) SIDE SERVICE CLEARANCE AIRFLOW SUCTION LINE SWEAT CONNECTION "D" TYP. "C" 3/8" (10) O. D. FLARE LIQUID LINE CONNECTION 0'-1 5/8" (41) 0'-2 9/16" (65) + + + + 0'-4 9/16" (116) 3/4" (19) N. P. T. DRAIN CONNECTION (FEMALE) NOTES: 1. Dimensions in parentheses are in millimeters. 1/4" 0'-1 (32) A91054 DIMENSIONS A B UNIT SERIES in. mm in. CE3AXA024 A 24 610 9-3/4 CE3AXA030 CE3AXA036 CE3AXA042 CE3AXA048 CE3AXA060 A A A A A 24 28-3/4 28-3/4 28-5/16 36-1/8 610 730 730 719 918 9-3/4 9-3/4 9-3/4 11-5/8 11-5/8 C mm 248 248 248 248 295 295 —2— in. 25-1/8 25-1/8 25-1/8 25-1/8 26-1/2 26-1/2 D mm 638 in. 638 21 21 21 20-7/8 20-7/8 638 638 673 673 21 E mm 533 in. 16 mm 406 533 16 406 533 533 530 530 23 23 23 33-3/4 584 584 857 857 SPECIFICATIONS COIL MODEL CE3A024 CE3A030 CE3A036 AIR QUANTITY (Cfm) Nominal 800 1000 1200 600–900 750–1200 900–1300 Metering Device Piston Number 59 67 70 Condensate Drains 2 2 2 R-22 R-22 R-22 46 49 55 CE3A042 CE3A048 CE3A060 Range COIL DATA AND REFRIGERANT Refrigerant Approximate Shipping Weight (lb) COIL MODEL AIR QUANTITY (Cfm) Nominal 1400 1600 2000 1050–1500 1200–1600 1600–2100 Metering Device Piston Number 78 84 90 Condensate Drains 2 2 2 R-22 R-22 R-22 58 65 72 Range COIL DATA AND REFRIGERANT Refrigerant Approximate Shipping Weight (lb) GROSS CAPACITIES (4-22)—1000 BTUH COIL REFRIGERANT TEMPERATURE (°F) 30 40 45 50 55 Evap Air—Entering Wet-Bulb Temp (°F) COIL CE3A Cfm BF 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 A024 600 0.09 800 0.11 1000 0.14 42 20 50 23 55 26 35 21 41 26 46 29 28 23 34 28 38 32 38 18 45 21 50 24 31 19 36 23 40 27 24 20 28 25 32 29 33 16 39 19 44 22 26 17 31 21 34 24 19 18 23 23 27 26 28 14 33 17 37 19 20 15 24 19 27 22 16 16 19 19 23 23 22 12 26 14 29 16 15 13 17 16 20 18 13 13 16 16 19 19 A030 750 0.08 1000 0.11 1250 0.13 51 24 59 28 64 31 42 26 49 31 54 35 35 28 41 34 45 39 47 22 54 26 59 29 38 24 44 29 48 33 30 26 35 31 39 36 41 20 48 23 53 26 32 21 38 26 42 30 24 23 29 28 33 33 35 17 41 21 45 24 26 19 30 23 34 27 20 20 26 25 29 29 28 15 33 18 36 21 19 16 23 20 25 23 17 17 20 20 24 24 A036 900 0.09 1200 0.12 1500 0.14 64 30 76 36 85 40 52 32 62 39 70 45 42 34 50 41 56 48 57 27 68 32 76 36 45 29 54 35 61 41 35 30 42 37 48 44 50 24 59 29 67 33 38 25 45 31 51 36 28 27 34 33 39 39 42 21 49 25 55 29 30 22 36 27 40 32 23 23 28 28 33 33 32 17 38 21 43 25 21 18 25 23 29 27 19 19 23 23 27 37 A042 1050 0.08 1400 0.11 1750 0.13 71 34 83 39 92 44 59 36 69 44 77 50 47 39 56 47 63 55 64 30 75 36 84 41 51 33 61 40 68 46 40 35 48 43 54 50 57 27 66 32 74 37 43 29 51 36 57 42 33 31 39 38 45 45 47 24 56 29 62 33 34 26 40 32 45 37 27 27 33 33 39 39 37 20 44 24 49 28 25 22 29 27 33 32 22 22 127 27 32 32 A048 1200 0.14 1600 0.17 2000 0.20 72 34 82 39 90 43 59 37 68 44 75 50 47 40 55 48 61 55 64 31 74 36 81 40 51 34 59 40 66 46 40 36 47 44 52 50 56 27 65 32 72 36 43 30 50 36 55 42 32 32 39 39 45 45 47 24 54 28 60 32 33 26 39 32 43 37 27 27 33 33 38 38 36 20 42 24 46 28 24 22 28 27 32 32 23 23 27 27 32 32 A060 1600 0.19 2000 0.22 2400 0.24 91 42 101 48 110 52 74 46 83 53 91 59 59 49 67 57 73 64 81 38 90 43 98 47 64 42 72 48 78 53 50 45 56 52 61 58 70 34 78 38 84 42 53 37 59 43 65 48 40 39 46 46 51 51 57 29 64 33 70 37 41 32 46 37 50 42 34 34 39 39 43 43 44 25 48 28 52 31 29 27 33 31 36 36 28 28 32 32 36 36 Sensible Heat Capacities (1000 Btuh) shown in italics. BF—Bypass Factor CFM—Indoor Evaporator Air NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. Fan motor heat has not been deducted. 3. SHC is based on 80°F db temperature of air entering the evaporator coil. Below 80°F db, subtract (corr factor x cfm) from SHC. Above 80°F db, add (corr factor x cfm) to SHC. 4. All data points are based on 10 degrees superheat leaving coil, and use of TXV for expansion device. —3— ENTERING AIR DRY BULB TEMPERATURE (°F) BYPASS FACTOR 0.10 0.20 0.30 79 78 81 82 0.98 0.87 0.76 1.96 1.74 1.53 77 76 75 83 84 84 Correction Factor 2.94 3.92 4.91 2.62 3.49 4.36 2.29 3.05 3.82 Under 75 Over 85 Use formula shown below COIL STATIC PRESSURE DROP (In. wc) MODEL CE3A AIR QUANTITY (CFM) 600 700 800 900 0.23 0.15 0.28 0.19 0.34 0.23 A024 WET DRY 0.18 0.12 700 800 900 1000 1100 1200 A030 WET DRY 0.14 0.09 0.17 0.11 0.21 0.14 0.25 0.16 0.29 0.19 0.33 0.22 900 1000 1100 1200 1300 A036 WET DRY 0.19 0.13 0.22 0.14 0.25 0.17 0.30 0.19 0.33 0.22 1000 1100 1200 1300 1400 1500 A042 WET DRY 0.16 0.12 0.19 0.14 0.22 0.16 0.25 0.18 0.28 0.20 0.31 0.22 1200 1300 1400 1500 1600 A048 WET DRY 0.22 0.15 0.25 0.18 0.28 0.20 0.30 0.22 0.34 0.24 1600 1700 1800 1900 2000 2100 A060 WET DRY 0.22 0.14 0.24 0.16 0.26 0.17 0.28 0.19 0.30 0.21 0.33 0.23 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS © 1992 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231 Catalog No. 92-32CE-3A1B PRINTED IN U.S.A. 8-92