Product group data DIL00AM General Standards and specifications IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated DC operated Operations × 106 10 Operations 106 10 × Operating frequency, mechanical AC operated Operations/h 7000 DC operated Operations/h 9000 Maximum operating frequency Operating frequency See Page 5/6 Damp heat, constant, to IEC 60068-2-3/Damp heat, cyclical, to IEC 60068-2-30 Climatic proofing Ambient temperature Open °C -25/50 enclosed °C -25/40 Mounting position See Page 10 Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 20 ms Main contacts Make contact g 10 Make contact g 10 Break contact g 6 Auxiliary contacts Degree of protection IP20 Protection against direct contact from the front when actuated by a perpendicular test finger (IEC 536) Finger and back-of-hand proof Weight AC operated kg 0,32 DC operated kg 0,5 Terminal capacity Main cable Solid mm2 1 × (0.75 – 4) 2 × (0.75 – 4) Flexible with ferrule mm2 1 × (0.75 – 4) 2 × (0.75 – 4) Solid or stranded AWG 18 – 10 Terminal screw M3.5 Nm 1.2 Solid mm2 1 × (0.75 – 4) 2 × (0.75 – 4) Flexible with ferrule mm2 1 × (0.75 – 2.5) 2 × (0.75 – 2.5) Solid or stranded AWG 18 – 12 Tightening torque Terminal capacity Control circuit cables Terminal screw M3.5 Tightening torque Nm 1.2 Size 2 Size 2 V AC 8000 Tool Main cable Pozidriv screwdriver Control circuit cables Pozidriv screwdriver Main conducting paths Rated impulse withstand voltage Uimp Overvoltage category/pollution degree III/3 Rated insulation voltage AC Rated operational voltage Ui V AC 690 Ue V AC 690 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 440 between the contacts V AC 440 A 200 220/230 V A 130 380/400 V A 120 500 V AC A 120 660/690 V A 100 Making capacity (cos to IEC/EN 60947) Breaking capacity Component lifespan AC-3 component lifespan See Page 8 AC-4 component lifespan See Page 9 AC-1 component lifespan See Page 7 Short-circuit rating Short-circuit protection Maximum fuse Type “2” coordination 400 V gG/gL 500 V A 20 gG/gL 500 V A 25 at 40 °C A 22 at 50 °C A 20 at 55 °C A 19 A 16 open A 50 Enclosed A 40 Type “1” coordination 400 V AC AC-1 duty conv. therm. current 3-pole 50 – 60 Hz open Enclosed Conventional thermal current, 1-pole AC-3 duty Rated operational current AC-3 open, 50 – 60 Hz, 3-pole 220/230 V Ie A 12 240 V Ie A 12 380/400 V Ie A 12 415 V Ie A 12 440V Ie A 12 500 V Ie A 12 660/690 V Ie A 9 220/230 V P kW 3 240V P kW 3,5 380/400 V P kW 5,5 415 V P kW 6,1 440 V P kW 6,4 500 V P kW 7,5 660/690 V P kW 7,5 220/230 V Ie A 8,7 240 V Ie A 8,7 380/400 V Ie A 8,5 415 V Ie A 8,5 Motor rating AC-4 duty Rated operational current AC-4 open, 50 – 60 Hz, 3-pole 440 V Ie A 8,5 500 V Ie A 9 660/690 V Ie A 6,7 220/230 V P kW 2,2 240 V P kW 2,5 380/400 V P kW 4 415 V P kW 4,2 440 V P kW 4,4 500 V P kW 5,5 660/690 V P kW 5,5 Motor rating Condensor operation Individual compensation, rated operational current Ie of three-phase capacitors open 525 V A 6 690 V A 7 525 V A 6 690 V A 7 enclosed Max. inrush current peak Component lifespan mA × Ie <30 Operations × 106 0,1 Operations/h 200 DC Operations Switching DC current See Pages 5/6 Rated operational current, open DC-1 operation 60 V A 20 110 V A 20 220 V A 15 440 V A 3 60 V A 20 110 V A 20 220 V A 8 60 V A 16 110 V A 16 Current heat loss (3-pole) at Ith W 2,3 Current heat losses (3-pole) at Ie to AC-3/400 V W 0,8 DC-3 operation DC-5 operation Current heat loss (3-pole) Magnet systems Voltage tolerance AC operated × Uc 0,8 – 1,1 DC operated × Uc 0,85 – 1,1 Power consumption of the coil at cold coil and 1.0 × Uc Pick-up AC VA 67 Pick-up AC W 52 Single-voltage coil 50 Hz, sealing VA 8,5 Single-voltage coil 50 Hz, sealing W 2,5 Dual-voltage coil 50 Hz, 60 Hz, sealing VA 8,6 Dual-voltage coil 50 Hz, 60 Hz, sealing W 2,5 Dual-frequency coil 50/60 Hz at 50 Hz Sealing VA 10 Dual-frequency coil 50/60 Hz at 50 Hz Sealing W 3 Dual-frequency coil 50/60 Hz at 60 Hz Sealing VA 8,5 Dual-frequency coil 50/60 Hz at 60 Hz Sealing W 2,5 Pick-up DC W 9,5 Sealing DC W 9,5 Duty factor % DF 100 Switching times at 100 % Uc (approximate values) Main contacts AC operated Closing delay ms 14 – 22 Opening delay ms 5 – 14 ms 13 – 21 ms 10 DC operated Reversing contactors Changeover time at 100 % Uc Arcing time Lifespan, mechanical of the coil 50/60 Hz at 50 Hz Mechanical lifespan at 50 Hz approx. 30 % less than listed under General technical data Notes See Page 10 Dimensions See Page 10 © 2003 by Moeller GmbH 06/084 Moeller HPL0211-2002 Engineering notes DIL contactors Determination of the maximum number of operations per hour in relation to rating and utilization category (approximate values), at 400 V PN = Max. motor rating (kW) of the relevant contactor Ops./h = Maximum number of switching operations per hour Type Ops./h 9000 Contactors 6000 DILE(E)M DIL00M(-G) DIL00AM(-G) DIL0M(-G) DIL0AM(-G) DIL1M(-G) DIL1AM(-G) DIL2M(-G) DIL2AM(-G) 5000 4000 3000 a 2000 b 1500 Tripping characteristic AC-1 AC-3 AC-2 AC-4 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 1000 800 c 600 500 400 300 200 150 100 0 10 20 30 40 50 60 70 80 90 100 % N [kW] Determination of the maximum number of operations per hour in relation to rating and utilization category (approximate values), at 400 V PN = Max. motor rating (kW) of the relevant contactor Ops./h = Maximum number of switching operations per hour Type Ops./h 4000 a b c 3000 2000 1500 d 1000 e DIL3M80 DIL3AM85 DIL4M115 DIL4AM145 DILM185 DILM225 DILM250 DILM300 DILM400 DILM500 DILM580 DILM650 DILM750 DILM820 800 600 f 500 g 400 h 300 200 i 150 100 50 0 10 20 30 40 50 60 70 80 90 100 % PN [kW] Tripping characteristic AC-1-1 AC-3 AC-4 2 2 2 2 2 2 2 3 3 3 3 3 3 3 1 1 3 3 1 1 1 2 2 2 4 4 4 4 5 5 6 6 8 8 8 9 9 9 7 7 7 7 06/085 Moeller HPL0211-2002 Engineering notes DIL contactors Switching DC DILEEM to DILM820 Without overload relay 60 V DC 60 V DC With overload relay 60V DC 1-pole Contactors – – – – conductor can be installed by the customer as required 2-pole DILEM4 DIL00M4 DILP160 to DILP800 1-pole 2-pole 06/082 Moeller HPL0211-2002 Tripping characteristics DIL contactors Switching duty for non-motor loads, 3-pole, 4-pole Operating characteristics Non-inductive or slightly inductive loads Electrical characteristics Make: 1 rated current Break: 1 rated current Typical applications Electric heaters Breaking cuzrrent A Contactors Utilization category 100 % AC-1 AC-1/400 V 850 DILM580-820 700 550 DILM300-500 400 DILM185-250 300 200 DIL4 AM145 DIL4 M115 DIL3(A)M80/85 DIL2(A)M DIL2M DIL1AM DIL1M DIL0AM DIL0M 160 100 70 50 40 30 DIL00AM DIL00M DILEM 20 10 7 5 4 3 maximum conventional thermal current I th for enclosed type 2 1 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 Component lifespan (Millions of operations) Breaking current A AC-1/400V 850 800 700 630 500 DILP800 DILP630 DILP500 315 250 200 DILP315 DILP250 160 DILP160 100 70 50 30 20 10 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 Component lifespan (Millions of operations) 06/080 Moeller HPL0211-2002 Rated output of three-phase motors 50–60 HZ kW 30 22 18.5 15 11 Rated operational current Ie 50 – 60 Hz Normal switching duty Squirrel-cage motors Operating characteristics Starting: from rest Stopping: after attaining full running speed Electrical characteristics Make: up to 6 rated motor current Break: up to 1 rated motor current Utilization category 100 % AC-3 Typical applications Compressors Lifts Mixers Pumps Escalators Agitators Fans Conveyor belts Centrifuges Valves Bucket elevators Air-conditioning systems Drives in general in manufacturing and processing machines AC-3/400 V A 58 DIL2AM 43 DIL2M 36 DIL1AM 30 DIL1M 23 DIL0AM 7.5 16 DIL0M DIL00BM 5.5 12 DIL00AM 4 8.8 DIL00M DILEM 3 6.5 DILEEM 2.2 5 1.5 3.5 1.1 2.5 0.8 2 0.55 1.6 DIL00BM DILE(E)M-G DIL00M DILE(E)M 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 0.75 1 2 3 4 5 6 8 10 Component lifespan (millions of operations) AC-3/400 V A 820 750 DILM820 DILM750 650 580 DILM650 DILM580 500 400 300 DILM500 DILM400 DILM300 250 225 DILM250 DILM225 90 185 DILM185 75 142 DIL4AM145 55 104 DIL4M115 45 85 DIL3AM85 37 72 DIL3M80 30 58 kW 450 400 355 315 250 200 160 132 110 Rated operational current Ie 50–60 Hz Rated output of three-phase motors 50–60 HZ Contactors Tripping characteristics DIL contactors 22 43 18.5 36 15 30 11 7.5 23 16 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 0.75 1 2 3 4 5 6 8 10 Component lifespan (millions of operations) Moeller HPL0211-2002 06/081 Tripping characteristics DIL contactors kW 22 18.5 15 11 7.5 5.5 Rated operational current Ie 50 – 60 Hz Rated output of three-phase motors 50–60 HZ Extreme switching duty Squirrel-cage motors Operating characteristics Inching, plugging, reversing Electrical characteristics Make: up to 6 rated motor current Break: up to 6 rated motor current Utilization category 100 % AC-4 4 Contactors Typical applications Printing presses Wire-drawing machines Centrifuges Special drives for manufacturing and processing machines AC-4/400 V A 43 DIL2AM 36 DIL2M 30 DIL1AM 23 DIL1M 16 DIL0AM 12 DIL0M 8.8 DIL00AM 3 6.5 DIL00M DILEM 2.2 5 DILEEM 1.5 3.5 1.1 2.5 0.8 2 0.55 1.6 0.37 1.2 0.25 0.8 0.02 0.03 0.04 0.06 0.1 0.01 0.2 0.3 0.4 0.6 1 2 3 4 5 6 8 10 Rated output of three-phase motors 50–60 HZ kW 355 315 280 250 200 160 132 Rated operational current Ie 50–60 Hz Component lifespan (millions of operations) AC-4/400 V A 656 DILM820 576 512 456 360 DILM750 DILM650 DILM580 DILM500 296 DILM400 240 DILM300 110 200 DILM250 90 75 164 140 DILM225 DILM185 55 104 DIL4AM145 45 37 85 72 DIL4M115 DIL3AM85 DIL3M80 30 58 22 18.5 43 36 15 30 11 23 7.5 16 5.5 12 4 8.8 3 6.5 2.2 5 1.5 3.5 0.01 0.02 0.03 0.04 0.06 0.1 0.2 0.3 0.4 0.6 1 2 3 4 5 6 8 10 Component lifespan (millions of operations) From DILM3M80 upwards mechanical shock resistance, half-sinusoidal shock; 10 ms The following applies for the solid main conductor cross-sections: Maximum of one size difference admissible when using 2 conductors The following applies for flat main conductor cross-sections: From DILM185, fix with flat conductor clamps or cable terminal blocks The following applies for the short-circuit rating and fusing of the main: See the "Fuses" transparent overlay for time/current characteristics (please enquire). The following applies to the voltage tolerance of the DC operated magnet system as well as the magnet system switching times with 100 % DC actuated main circuit. Smoothed DC or three-phase current bridge rectifier; at least two-pulse bridge rectifier following values apply with the max. permissible ambient temperature: AC voltage AC-1 duty, conv. therm. current, enclosed AC-1 duty 1-pole, open AC-1 duty 1-pole, enclosed AC-3 duty, rated operational current, open AC-4 duty, rated operational current, open The following applies to magnet system switching times with 100 % AC operated reversing contactors Changeover time at 100 % Uc. DIL00(A)M can be reversed at 660/690 V with a zero-current pause 25 ms The following applies to magnet system, voltage tolerance, AC operated, pick-up voltages. With 50/60 Hz coil: 0.85 – 1.1 Mounting Position