Technical Information Cable Structure Data VDE standard 0295 specifies that only the maximum single wire diameter and the corresponding highest-permissible electrical resistance have to be determined for each cable cross-section. Cables Made of Uninsulated or Tin-Plated Copper Wires Number of Wires x Wire Diameter [mm] VDE 0295 Conductor Single wire Stranded Cross-Section Class 1 Class 2 [mm²] FinelyStranded* Class 5 Extra Finely-Stranded* Class 6 0.10 14 x0.10 26 x 0.07 50 x 0.05 0.14 18 x 0.10 36 x 0.07 72 x 0.05 0.25 14 x 0.15 32 x 01.0 65 x 0.07 128 x 0.05 7 x 0.25 19 x 0.15 43 x 0.10 88 x 0.07 180 x 0.05 0.34 7 x 0.30 16x 0.20 28 x 0.15 63 x 0.10 129 x 0.07 258 x 0.05 0.75 1 x 1.00 7 x 0.37 24 x 0.20 42 x 0.15 95 x 0.10 196 x 0.07 384 x 0.05 1.00 1 x 1.13 7 x 0.43 32 x 0.20 56 x 0.15 127 x 0.10 258 x 0.07 512 x 0.05 1.50 1 x 1.38 7 x 0.52 30 x 0.25 84 x 0.15 191 x 0.10 385 x 0.07 768 x 0.05 2.50 1 x 1.78 7 x 0.67 50 x 0.25 140 x 015 320 x 0.10 651 x 0.07 1281 x 0.05 4.00 1 x 2.26 7 x 0.85 56 x 0.30 224 x 0.15 512 x 0.10 1036 x 0.07 6.00 1 x 2.77 7 x 1.05 84 x 0.30 192 x 0.20 765 x 0.10 1561 x 0.07 10.00 1 x 3.57 7 x 1.35 80 x 0.40 320 x 0.20 1275 x 0.10 Accessories, Connectors, Cordsets, Splitters 1 x 0.80 Accessories 0.50 10 10 * The number of wires in finely and extra finely-stranded cable structures are preferred values. Shield Connection The type of shield connection is primarily decided by the nature of the expected interference. 1 To suppress electrical fields, the shield must be grounded (1) at one end. However, interference caused by a magnetic alternating field can only be suppressed if the shield is connected at both ends (2). A ground loop, including all its known disadvantages, is created when a shield is connected at both ends. The useful signal is particularly susceptible to noise on the reference voltage. Triaxial cables (4) combat this effect. The internal shield is connected at one end, whereas the external shield is connected at both ends. 2 Interference of this nature when a cable shield is connected at both ends is often reduced by also connecting one end of the shield to the reference potential via a capacitor (3). This breaks the ground loop, at least for direct currents and low-frequency currents. 3 4 Refer to General Notes Relating to Product Information Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0001 fa-info@us.pepperl-fuchs.com Germany: +49 621 776-4411 fa-info@de.pepperl-fuchs.com Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com .1 1063