CEILING PLAN GENERAL NOTES CEILING PLAN LEGEND N

advertisement
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
150
1"=50'
100
50
0
100
200
300
1"=100'
CEILING PLAN
GENERAL NOTES
A.
B.
CEILING PLAN LEGEND
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
WHERE NO FINISH CEILING IS INDICATED, THE ROOM/SPACE
SHALL BE EXPOSED TO THE STRUCTURE ABOVE. REFER TO
ROOM FINISH SCHEDULE FOR FINISHING REQUIREMENTS.
1HR FIRE RESISTANCE RATED BARRIER
2HR FIRE RESISTANCE RATED BARRIER
COORDINATE FINAL SIZE AND FINAL LOCATION OF ALL
ACCESS PANELS WITH TRADE REQUIRING SAME.
CUBICLE CURTAIN TRACK, SEE SHT A5-51
C. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER
CEILING SPACE EQUIPMENT SUPPORTING DEVICES.
I.V. TRACK, SEE SHT A5-51
D. FOR PARTITION TYPES, SEE SHEET A5-71 AND A5-72.
E.
SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND NIGHT
LIGHT LOCATIONS
F.
CEILING GRID LAYOUT - SYSTEM TO BE CENTERED IN ROOM,
IN BOTH DIRECTIONS, UNO. CEILING GRID AREAS DIVIDED BY
SOFFITS/DOORS TO BE ALIGNED. WORKPOINT MARKERS /
DIMENSIONS SHALL SUPERCEDE, WHERE PROVIDED. ASSUME
WORKPOINT STARTER PANELS TO BE FULL SIZE OR 6",
UNLESS DIMENSIONED.
C.H.
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
C.J.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
G. NO CEILING PANEL TO BE CUT TO LESS THAN 6" WIDTH,
TYPICAL AT CONDITIONS WHERE CEILING PANELS EXCEED
2'-0" TRIM 2' X 4' CEILING PANELS AS REQ'D TO FIT.
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
H. COORDINATE THE LOCATION OF ESCUTCHEON PLATES AT
CEILING PANEL PENETRATIONS WITH ELECTRICAL AND
MECHANICAL TRADES.
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
I.
SPRINKLER HEADS TO BE LOCATED IN THE CENTER OF
CEILING PANELS, UNO.
J.
PAINT ALL VISIBLE, EXPOSED CONSTRUCTION ABOVE
CEILINGS INCLUDING BUT NOT LIMITED TO MECH & ELEC
ITEMS. SEE NOTES ON A6-1x SERIES DWGS FOR EXTENT.
RETURN AIR DIFFUSER
FIELD VERIFY LOCATIONS OF SOFFIT & CEILING CONTROL
JOINTS WITH THE A/E REP.
LINEAR DIFFUSER
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
311 Mack Avenue
Detroit, Michigan 48201
SUPPLY AIR DIFFUSER
B-2
B-1
K.
1
L.
A5-05
REFER TO AQ-XX SERIES DRAWINGS FOR ADDITIONAL INFO
ON CEILING MOUNTED EQUIPMENT.
CLG MTD MED GAS
SEE DETAIL 8/A5-52
M. PATCH AND REPAIR EXISTING CEILING PANELS AND GRID
WHERE WALLS ARE REMOVED.
2.2
CLG MTD POWER
SEE DETAIL 9/A5-52
N. CONTRACTOR SHALL MAINTAIN THE FIRE RATING INTEGRITY
OF ALL EXISTING PARTITIONS INDICATED AS FIRE
RESISTANCE RATED. ADVISE THE ARCHITECT OF ANY PREEXISTING BREACHES DISCOVERED IN COURSE OF WORK.
C.J.
DOWN LIGHT FIXTURE
FLUORESCENT FIXTURE
O. GYPSUM BD CEILINGS & SOFFITS TO BE CONSTRUCTED W/
5/8" THK GYPSUM BOARD, AS INDICATED ON TYP DETAILS
OF SHT A5-51, TO COORD WITH LT FIXTURE REQUIREMENTS.
5
A4-501
3
P/R 5
11030E
8' - 6"
C.H.
CONSULT
11017
SHELLED
P/R AREA
11030-0
SEC/FIRE
COMMAND
11003
9' - 0"
C.H.
A.5
C.J.
C.J.
C.J.
SUPPLEMENTAL
GRID @ SPLIT PANEL
CEILING CJ'S
CLARIFIED IN
C.J.
PRE-AWARD
RFI 083 RESPONSE
C.J.
15' - 4"
C.H.
15' - 4"
C.H.
9' - 0"
C.H.
9' - 0"
C.H.
7' - 2"
C.H.
9' - 0"
C.H.
S INTER P/R
11030
A.4
9' - 0"
C.H.
7' - 2"
C.H.
REFER TO DWG A9-31
FOR ALT. #3 FIT-OUT
TYP POCKET
DET E/A5-51
9' - 4"
C.H.
12' - 0"
C.H.
PUB TLT
11016
8' - 0"
C.H.
62'-0"
2
A5-04
TYP POCKET
DET 'E'/A5-51
13'-4"
13'-4"
VESTIBULE
11001
8' - 6"
C.H.
C.J.
OVERHEAD EXAM
LIGHT REFER TO
DETAILS
RECEPTION
11010
10' - 0"
C.H.
13'-4"
15' - 6"
C.H.
D.E.F.S.
CONTROL
JOINT, TYP.
COMPOSITE
METAL PANEL
15' - 4"
C.H.
18' - 10 1/2"
C.H.
12' - 0"
C.H.
PROCEDURE
1
11026
18' - 10 1/2"
C.H.
SCRUB 8
11082
C.J.
1'-0"
SKYLIGHT, TYP. OF 2
(ALUM. FRAMING
SYSTEM 'E')
18' - 10 1/2"
C.H.
15' - 6"
C.H.
B.7
ACCESS
DOOR
17' - 10 1/2"
C.H.
12' - 0"
C.H.
ELEC
11021
SCRUB 9
11083
COMPOSITE METAL PANEL
ACCESS
DOOR
6
A5-27
TYP.
12'-0"
SCRUB 7
11081
8' - 6"
C.H.
1'-0"
16' - 10 1/2"
C.H.
C.J.
COMM
11020
18' - 10 1/2"
C.H.
B.6
1'-0" TYP.
8' - 6"
C.H.
8' - 6"
C.H.
18' - 10 1/2"
C.H.
1
7' - 2"
C.H.
8' - 6"
C.H.
REFER TO DWG A9-51
FOR ALT. #5 FIT-OUT
11' - 0"
C.H.
SHELLED
CATH LAB 3
11074-0
COMPOSITE
METAL PANEL
FUTURE
CATH LAB
4/5
11025
COMPOSITE METAL
PANEL JOINT TYP.
5'-8 1/2"
2
A5-52
REFER TO DWG A9-41
FOR ALT. #4 FIT-OUT
8'-0"
18' - 10 1/2"
C.H.
CLG POCKET
13'-4"
13'-4"
C.3
1'-0"
16' - 10 1/2"
C.H.
C.J.
1'-0"
10' - 8"
C.H.
1'-0"
CONTROL
11069B
CATH LAB 2
11069
C
A5-04
CLG POCKET
3'-0"
8' - 6"
C.H.
STF TLT
11060
CLEAN
SUPPLY
11059
C.J.
CORRIDOR
110Z5
8' - 6"
C.H.
16' - 10 1/2"
C.H.
C.J.
17' - 10 1/2"
C.H.
1'-0"
B.2
C.J.
HSKG
11031
INVENT
COORD
11058
TYP POCKET
DET 'E'/A5-51
B
TYP.
12'-0"
15' - 6"
C.H.
RETAIL
COFFEE
11012
1'-0"
6
A5-27
TECH
WORKROOM
11011
A.9
1'-0"
9' - 0"
C.H.
C.J.
3'-0"
SOILED
UTILITY
11034
CONT. SOFFIT
VENT, TYP.
3'-0"
A5-52
13'-4"
16' - 10 1/2"
C.H.
5
9' - 0"
C.H.
13'-4"
8'-0"
P/R 6
11030F
PUB TLT
11015
VALET
11002
12'-0"
P/R 7
11030G
GREETER
11004
0
4'-0"
8' - 6"
C.H.
10' - 2"
C.H.
10' - 0"
C.H.
4'-0"
8' - 6"
C.H.
CAMERA
A
12'-0"
8' - 6"
C.H.
JUNCTION BOX IN CEILING
1'-0"
8' - 0"
C.H.
10' - 2"
C.H.
16' - 10 1/2"
C.H.
12' - 0"
C.H.
NURSE CALL DOME LIGHT
TYP POCKET
DET E/A5-51
A4-05
15' - 4"
C.H.
10' - 0"
C.H.
SPEAKER (GRILLE)
3'-0"
10' - 0"
C.H.
S
1'-0"
10' - 0"
C.H.
22'-0"
10' - 0"
C.H.
10' - 0"
C.H.
EQ.
SMOKE DETECTORS
13'-4"
13'-4"
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
NOTE:
COMPOSITE METAL PANEL JOINTS
ALIGN WITH D.E.F.S. CONTROL
JOINTS, U.O.N.
13'-4"
15' - 6"
C.H.
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
14
CEILING CJ'S CLARIFIED IN
PRE-AWARD RFI 083 RESPONSE
C.J.
C.J.
A5-72
EQUIP
11069A
Issue
Progress Set 2
Construction Issue 10
Scope Review Set
Construction Issue 12
Construction Issue 13
1'-0"
EQ.
S
4
15' - 4"
C.H.
1'-11 1/2"
10' - 0"
C.H.
EQ.
2'-0"
22'-0"
5'-8"
10' - 0"
C.H.
EQ.
7'-11 1/2"
EQ.
A5-52
22'-0"
Date
12/21/11
05/30/12
06/27/12
07/18/12
08/08/12
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
D
D.1
8' - 6"
C.H.
4
A4-501
Copyright © 2011
2008
D.4
D.5
6
5
4
3
2
1.8
1.5
1.2
1.1
1
A
FIRST FLOOR REFLECTED CEILING PLAN - AREA A
N
0
1
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
2011-10001-000
M.J.Bednarczyk
K.Doyle
E.G.Essique
Title
First Floor
Reflected Ceiling
Plan - Area A
N
SCALE: 1/8" = 1'-0"
3"=1'0"
8/29/2013 11:17:55
AM
Project No.
Drawn
Checked
Approved
KEYPLAN
Sheet No.
AR-1A
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
150
1"=50'
100
50
0
100
200
300
1"=100'
CEILING PLAN
GENERAL NOTES
2
A4-12
A.
WHERE NO FINISH CEILING IS INDICATED, THE ROOM/SPACE
SHALL BE EXPOSED TO THE STRUCTURE ABOVE. REFER TO
ROOM FINISH SCHEDULE FOR FINISHING REQUIREMENTS.
B.
COORDINATE FINAL SIZE AND FINAL LOCATION OF ALL
ACCESS PANELS WITH TRADE REQUIRING SAME.
A
11
A4-04
C. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER
CEILING SPACE EQUIPMENT SUPPORTING DEVICES.
WATER
METER RM
B1002
D. FOR PARTITION TYPES, SEE SHEET A5-71 AND A5-72.
E.
SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND NIGHT
LIGHT LOCATIONS
F.
CEILING GRID LAYOUT - SYSTEM TO BE CENTERED IN ROOM,
IN BOTH DIRECTIONS, UNO. CEILING GRID AREAS DIVIDED BY
SOFFITS/DOORS TO BE ALIGNED. WORKPOINT MARKERS /
DIMENSIONS SHALL SUPERCEDE, WHERE PROVIDED. ASSUME
WORKPOINT STARTER PANELS TO BE FULL SIZE OR 6",
UNLESS DIMENSIONED.
A.3
SHAFT #8
A.6
G. NO CEILING PANEL TO BE CUT TO LESS THAN 6" WIDTH,
TYPICAL AT CONDITIONS WHERE CEILING PANELS EXCEED
2'-0" TRIM 2' X 4' CEILING PANELS AS REQ'D TO FIT.
A.7
H. COORDINATE THE LOCATION OF ESCUTCHEON PLATES AT
CEILING PANEL PENETRATIONS WITH ELECTRICAL AND
MECHANICAL TRADES.
12.4
12.1
11.9
11.4
11.3
SPRINKLER HEADS TO BE LOCATED IN THE CENTER OF
CEILING PANELS, UNO.
J.
PAINT ALL VISIBLE, EXPOSED CONSTRUCTION ABOVE
CEILINGS INCLUDING BUT NOT LIMITED TO MECH & ELEC
ITEMS. SEE NOTES ON A6-1x SERIES DWGS FOR EXTENT.
K.
FIELD VERIFY LOCATIONS OF SOFFIT & CEILING CONTROL
JOINTS WITH THE A/E REP.
L.
REFER TO AQ-XX SERIES DRAWINGS FOR ADDITIONAL INFO
ON CEILING MOUNTED EQUIPMENT.
11
BASEMENT REFLECTED CEILING PLAN
2
A2-02
I.
SCALE: 1/8" = 1'-0"
M. PATCH AND REPAIR EXISTING CEILING PANELS AND GRID
WHERE WALLS ARE REMOVED.
N. CONTRACTOR SHALL MAINTAIN THE FIRE RATING INTEGRITY
OF ALL EXISTING PARTITIONS INDICATED AS FIRE
RESISTANCE RATED. ADVISE THE ARCHITECT OF ANY PREEXISTING BREACHES DISCOVERED IN COURSE OF WORK.
2
A5-01
O. GYPSUM BD CEILINGS & SOFFITS TO BE CONSTRUCTED W/
5/8" THK GYPSUM BOARD, AS INDICATED ON TYP DETAILS
OF SHT A5-51, TO COORD WITH LT FIXTURE REQUIREMENTS.
3
EQ.
A5-52
21'-10 1/2"
EQ.
EQ.
8'-0"
1
A4-501
12' - 0"
C.H.
12' - 0"
C.H.
A.3
N ELEV 2
FUTURE
110V6
N ELEV 4
PUBLIC
110V8
N ELEV 3
SERVICE
110V7
SHAFT #8
.
A5-04
OFFICE
11046
OFFICE
11045
8' - 6"
C.H.
8' - 6"
C.H.
P/R 16
11040H
8' - 6"
C.H.
P/R 15
11040G
8' - 6"
C.H.
P/R 14
11040F
8' - 6"
C.H.
P/R 13
11040E
10' - 0"
C.H.
P/R 12
11040D
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
P/R 11
11040C
P/R 10
11040B
P/R 9
11040A
1HR FIRE RESISTANCE RATED BARRIER
2HR FIRE RESISTANCE RATED BARRIER
CUBICLE CURTAIN TRACK, SEE SHT A5-51
8' - 6"
C.H.
NOURISH
11041
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
P/R 8
11030H
P/R 7
11030G
P/R 6
11030F
P/R 5
11030E
I.V. TRACK, SEE SHT A5-51
C.H.
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
C.J.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
5
NW ELEV
LOBBY
110Z10
S
REWORK EX
CLG AS REQ'D
BY WALL WORK
A5-51
9' - 6"
C.H.
11.3
7' - 0"
C.H.
7' - 10"
C.H.
OFFICE
11047
8' - 6"
C.H.
B.1
OFFICE
11048
8' - 6"
C.H.
P/R 24
11040N
8' - 6"
C.H.
8' - 6"
C.H.
P/R 23
11040M
P/R 22
11040L
NURSE
STATION
11043
PAT TLT
11044
7' - 2"
C.H.
8' - 6"
C.H.
8' - 0"
C.H.
8' - 6"
C.H.
CORRIDOR
110Z7
SOILED
UTILITY
11053
SCRUB 1
11075
S
8' - 0"
C.H.
7' - 2"
C.H.
7' - 0"
C.H.
8' - 6"
C.H.
9' - 1"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
CONTROL
11061B
SCRUB 3
11077
LOCKERS
G713
97
C.4
CATH LAB
LARGE
11064
EP LAB 2
11062
SCRUB 5
11079
APRON
11057
SCRUB 6
11080
8' - 6"
C.H.
CONTROL
11065B
8' - 6"
C.H.
SWING LAB
1A
11066
CATH LAB 1
11065
9' - 6"
C.H.
9' - 4"
C.H.
8' - 6"
C.H.
SWING LAB
1B
11067
CONTROL
11068
12.5
12.4
12.2
12.1
DOWN LIGHT FIXTURE
S
SMOKE DETECTORS
S
SPEAKER (GRILLE)
CONTROL
11069B
NURSE CALL DOME LIGHT
CATH LAB 2
11069
JUNCTION BOX IN CEILING
10' - 8"
C.H.
CAMERA
9' - 6 3/8"
C.H.
9' - 6 3/8"
C.H.
9' - 4"
C.H.
EQUIP
11062C
11.9
SCRUB 7
11081
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
8' - 0"
8' - 0"
C.H.
C.H.
G715
CLG MTD POWER
SEE DETAIL 9/A5-52
8' - 6"
C.H.
C
8' - 6"
C.H.
8' - 6"
C.H.
WORKROOM
11063
OFFICE
REWORK EX
CLG AS REQ'D
BY WALL WORK
INVENT
COORD
11058
FLUORESCENT FIXTURE
CONTROL
11064B
9' - 9"
C.H.
EP LAB 1
11061
CLG MTD MED GAS
SEE DETAIL 8/A5-52
7' - 2"
C.H.
8' - 6"
C.H.
2" CEILING EXP. JT.
TYPE 'CA-2'
DEVELOP
TRANSITION
SOFFIT FROM
REMAINING WALL
8' - 6"
C.H.
8' - 0"
C.H.
CONTROL
DESK
11056
8' - 6"
C.H.
8' - 6"
C.H.
CONTROL
11062B
LINEAR DIFFUSER
SCRUB 4
11078
STF TLT
11055
SCRUB 2
11076
CHANGE IN
CLG PLANE
@ GRID LINE
CR
EX
C.H.
7'-0"
7' - 6"
C.H.
RETURN AIR DIFFUSER
5'-8 1/2"
G719
HSKG
11054
SUPPLY AIR DIFFUSER
7' - 2"
C.H.
8' - 0"
C.H.
8' - 6"
C.H.
STF TLT
11052
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
SOILED
UTILITY
11034
PAT TLT
11036
NURSE
STATION
11037
CORRIDOR
110Z5
PACS
READING
11085
FELLOWS
11084
P/R 21 ISO
11040K
CLEAN
SUPPLY
11035
MEDS
11042
SATELLITE
PHARMACY
11049
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
B
8' - 6"
C.H.
9' - 0"
C.H.
S
WOMEN
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
9' - 0"
C.H.
EX
C.H.
7'-10"
EX
C.H.
7'-10"
S INTER P/R
11030
A5-51
S
7' - 10"
C.H.
VC
5
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
14
8' - 6"
C.H.
A5-72
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
9' - 6 3/8"
C.H.
9' - 4"
C.H.
9' - 6"
C.H.
STORAGE
8' - 6"
C.H.
G714
8' - 6"
C.H.
EQUIP
11061A
8' - 6"
C.H.
EQUIP
11061A
8' - 6"
C.H.
EQUIP
11064A
EQUIP
11062A
EQUIP
11064A
8' - 6"
C.H.
EQUIP
11065A
9' - 6 3/8"
C.H.
D
EQUIP
11069A
8' - 6"
C.H.
EQUIP
11066A
8' - 6"
C.H.
1
A4-502
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
8' - 6"
C.H.
3
A4-502
4
A4-502
2
A4-502
D.4
11.4
11
10
9
8
7
Copyright © 2011
2008
6
B
Project No.
Drawn
Checked
Approved
2011-10001-000
M.J.Bednarczyk
K.Doyle
E.G.Essique
Title
First Floor
Reflected Ceiling
Plan - Area B
FIRST FLOOR REFLECTED CEILING PLAN - AREA B
SCALE: 1/8" = 1'-0"
N
3"=1'0"
8/29/2013 11:18:20
AM
0
1
Issue
Progress Set 2
Scope Review Set
Construction Issue 12
Construction Issue 15
Construction Issue 18
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
A.7
N INTER P/R
11040
9' - 6"
C.H.
Date
12/21/11
06/27/12
07/18/12
01/23/13
05/24/13
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
9' - 0"
C.H.
TV
EX BRUSH
BLDG
N ELEV 1
PATIENT
110V5
A.6
4
8' - 6"
C.H.
8' - 6"
C.H.
10' - 0"
C.H.
7'-11 1/2"
8' - 0"
C.H.
N STAIR
110X5 8' - 0"
C.H.
10' - 0"
C.H.
NE ELEV
LOBBY
110Z9
10' - 0"
C.H.
311 Mack Avenue
Detroit, Michigan 48201
CEILING PLAN LEGEND
A
10' - 0"
C.H.
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
KEYPLAN
Sheet No.
AR-1B
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
1"=50'
150
100
50
0
100
200
300
1"=100'
CEILING PLAN
GENERAL NOTES
A.
WHERE NO FINISH CEILING IS INDICATED, THE ROOM/SPACE
SHALL BE EXPOSED TO THE STRUCTURE ABOVE. REFER TO
ROOM FINISH SCHEDULE FOR FINISHING REQUIREMENTS.
B.
COORDINATE FINAL SIZE AND FINAL LOCATION OF ALL
ACCESS PANELS WITH TRADE REQUIRING SAME.
C. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER
CEILING SPACE EQUIPMENT SUPPORTING DEVICES.
D. FOR PARTITION TYPES, SEE SHEET A5-71 AND A5-72.
E.
SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND NIGHT
LIGHT LOCATIONS
F.
CEILING GRID LAYOUT - SYSTEM TO BE CENTERED IN ROOM,
IN BOTH DIRECTIONS, UNO. CEILING GRID AREAS DIVIDED BY
SOFFITS/DOORS TO BE ALIGNED. WORKPOINT MARKERS /
DIMENSIONS SHALL SUPERCEDE, WHERE PROVIDED. ASSUME
WORKPOINT STARTER PANELS TO BE FULL SIZE OR 6",
UNLESS DIMENSIONED.
G. NO CEILING PANEL TO BE CUT TO LESS THAN 6" WIDTH,
TYPICAL AT CONDITIONS WHERE CEILING PANELS EXCEED
2'-0" TRIM 2' X 4' CEILING PANELS AS REQ'D TO FIT.
H. COORDINATE THE LOCATION OF ESCUTCHEON PLATES AT
CEILING PANEL PENETRATIONS WITH ELECTRICAL AND
MECHANICAL TRADES.
1
B-2
A5-05
B-1
2.2
I.
SPRINKLER HEADS TO BE LOCATED IN THE CENTER OF
CEILING PANELS, UNO.
J.
PAINT ALL VISIBLE, EXPOSED CONSTRUCTION ABOVE
CEILINGS INCLUDING BUT NOT LIMITED TO MECH & ELEC
ITEMS. SEE NOTES ON A6-1x SERIES DWGS FOR EXTENT.
K.
FIELD VERIFY LOCATIONS OF SOFFIT & CEILING CONTROL
JOINTS WITH THE A/E REP.
L.
REFER TO AQ-XX SERIES DRAWINGS FOR ADDITIONAL INFO
ON CEILING MOUNTED EQUIPMENT.
M. PATCH AND REPAIR EXISTING CEILING PANELS AND GRID
WHERE WALLS ARE REMOVED.
3
N. CONTRACTOR SHALL MAINTAIN THE FIRE RATING INTEGRITY
OF ALL EXISTING PARTITIONS INDICATED AS FIRE
RESISTANCE RATED. ADVISE THE ARCHITECT OF ANY PREEXISTING BREACHES DISCOVERED IN COURSE OF WORK.
EXPANSION JOINT 'PB-4',
3 FACES OF GYP BD ENCLOSURE, EACH SIDE
A5-52
O. GYPSUM BD CEILINGS & SOFFITS TO BE CONSTRUCTED W/
5/8" THK GYPSUM BOARD, AS INDICATED ON TYP DETAILS
OF SHT A5-51, TO COORD WITH LT FIXTURE REQUIREMENTS.
A
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
CORRIDOR/WTG
210Z1
CEILING CJ'S CLARIFIED IN
PRE-AWARD RFI 083 RESPONSE
CORRIDOR/WTG
210Z1
MALE
GOWNED
WTG
21036
7' - 2"
C.H.
9' - 0"
C.H.
ECHO 3
21044C
EQUIPMENT
21040B
9' - 0"
C.H.
9' - 0"
C.H.
8' - 6"
C.H.
5
8' - 6"
C.H.
A5-51
PASSAGE
21044
ECHO 2
21044A
PASSAGE
21040
ECHO 1
21040C
FEMALE
GOWNED
WTG
21037
9' - 0"
C.H.
TECH
WORKROOM
21040A
CHNG
21035
CHNG
21034
C.J.
ALIGN W/ 1ST
FLOOR JT
7' - 2"
C.H.
CHNG
21033
PUB TLT
21016
A5-51
8' - 6"
C.H.
9' - 0"
C.H.
EKG
21038
STRESS
ECHO 3
21045
STRESS
ECHO 2
21043
PAT TLT
21032
8' - 6"
C.H.
I.V. TRACK, SEE SHT A5-51
A.9
8' - 6"
C.H.
C.H.
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
C.J.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
B
CLG MTD
CAMERA, TYP
8' - 6"
C.H.
A4-301
22
C.J.
ALIGN W/ 1ST
FLOOR JT
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
B.2
CONSULT
21012
RETAIL
PHARMACY
21013
9' - 0"
C.H.
PAT SHWR
21031
VENIPUNCTURE
2
21061
CUBICLE CURTAIN TRACK, SEE SHT A5-51
A5-52
7' - 2"
C.H. 8' - 0"
C.H.
8' - 0"
C.H.
STRESS
ECHO 1
21042
VENIPUNCTURE
1
21060
2HR FIRE RESISTANCE RATED BARRIER
5
8' - 6"
C.H.
EKG
WORKROOM
21041
9' - 0"
C.H.
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
1HR FIRE RESISTANCE RATED BARRIER
8'-0"
8' - 6"
C.H.
5
8' - 6"
C.H.
LOCATE PENDANT
FIXT'S IN CENTER
OF 3RD FLOOR CLG
TILE (ABOVE), TYP
OPEN TO
BELOW
.
CONNECTED
LOBBY UPPER
210Z3
HSKG
21011
A.5
10' - 6"
C.H.
10' - 6"
C.H.
RECEPTION
21010
CORRIDOR
210Z4
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
?
?
SHAFT #3
.
CORRIDOR
210Z5
C.J.
7' - 2"
C.H.
B.6
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
B.7
SUPPLY AIR DIFFUSER
C.J.
4
RETURN AIR DIFFUSER
A5-51
9' - 0"
C.H.
PHYS
READING
21063
9' - 0"
C.H.
STF TLT
21025P
OFFICE
21013B
8' - 0"
C.H.
LINEAR DIFFUSER
C.J.
CLG MTD MED GAS
SEE DETAIL 8/A5-52
C
TREADMILL
1
21074
8' - 6"
C.H.
CORRIDOR
210Z7
9' - 0"
C.H.
9' - 0"
C.H.
HOT LAB
21062
9' - 0"
C.H.
STRESS
READING
21064
8' - 0"
C.H.
7' - 2"
C.H.
SHAFT #2
.
PROF
ALLOW
21025N
9' - 0"
C.H.
10' - 0"
C.H.
DOWN LIGHT FIXTURE
10' - 0"
C.H.
8' - 0"
C.H.
8' - 0"
C.H.
CLG MTD POWER
SEE DETAIL 9/A5-52
CEILING CJ'S CLARIFIED IN
PRE-AWARD RFI 083 RESPONSE
RECEPT
21025A
9' - 0"
C.H.
WORKROOM
21025B
STF TLT
21025R
PROF
ALLOW
21025Q
Issue
Progress Set 2
Scope Review Set
Construction Issue 12
Construction Issue 15
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
PUB TLT
21015
8' - 6"
C.H.
Date
12/21/11
06/27/12
07/18/12
01/23/13
A.4
STF
LOUNGE
21013A
8'-0"
10' - 6"
C.H.
311 Mack Avenue
Detroit, Michigan 48201
CEILING PLAN LEGEND
C.J.
WORKROOM
21044B
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
C.3
FLUORESCENT FIXTURE
C.J.
CONF
21025C
9' - 0"
C.H.
S ELEV
LOBBY
210Z2
S
SMOKE DETECTORS
S
SPEAKER (GRILLE)
NURSE CALL DOME LIGHT
NM
EQUIPMENT
21069
2
8' - 6"
C.H.
INJECTED
WTG
21065
JUNCTION BOX IN CEILING
A5-52
8' - 6"
C.H.
CAMERA
SEC
21025E
STF TLT
21068
8' - 6"
C.H.
DIRECTOR
21025M
DIRECTOR
21066
DIRECTOR
21025L
5
8' - 6"
C.H.
8' - 6"
C.H.
DIRECTOR
21025K
8' - 6"
C.H.
DIRECTOR
21025J
8' - 6"
C.H.
DIRECTOR
21025H
VICE
PRESIDENT
21025F
DIRECTOR
21025G
D
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
D.1
5
ROLLER SHADES (EA WINDOW, THIS AREA), SEE 12/A5-65
A5-51
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
9' - 0" PRESIDENT
21025D
C.H.
8' - 6"
C.H.
C.J.
INJECTED
TLT
21067
8' - 6"
C.H.
9' - 0"
C.H.
C.J.
8' - 6"
C.H.
A5-51
4
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
A2-01
3
A2-01
D.4
D.5
Copyright © 2011
2008
1
A2-02
6
5
4
3
2
1.8
1.5
1.2
1.1
1
A
SECOND FLOOR REFELECTED CEILING PLAN - AREA A
Project No.
Drawn
Checked
Approved
2011-10001-000
M.J.Bednarczyk
K.Doyle
E.G.Essique
Title
Second Floor
Reflected Ceiling
Plan - Area A
SCALE: 1/8" = 1'-0"
N
3"=1'0"
8/29/2013 11:18:40
AM
0
1
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
KEYPLAN
Sheet No.
AR-2A
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
150
1"=50'
100
50
0
100
200
300
1"=100'
CEILING PLAN
GENERAL NOTES
A.
WHERE NO FINISH CEILING IS INDICATED, THE ROOM/SPACE
SHALL BE EXPOSED TO THE STRUCTURE ABOVE. REFER TO
ROOM FINISH SCHEDULE FOR FINISHING REQUIREMENTS.
B.
COORDINATE FINAL SIZE AND FINAL LOCATION OF ALL
ACCESS PANELS WITH TRADE REQUIRING SAME.
C. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER
CEILING SPACE EQUIPMENT SUPPORTING DEVICES.
D. FOR PARTITION TYPES, SEE SHEET A5-71 AND A5-72.
E.
SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND NIGHT
LIGHT LOCATIONS
F.
CEILING GRID LAYOUT - SYSTEM TO BE CENTERED IN ROOM,
IN BOTH DIRECTIONS, UNO. CEILING GRID AREAS DIVIDED BY
SOFFITS/DOORS TO BE ALIGNED. WORKPOINT MARKERS /
DIMENSIONS SHALL SUPERCEDE, WHERE PROVIDED. ASSUME
WORKPOINT STARTER PANELS TO BE FULL SIZE OR 6",
UNLESS DIMENSIONED.
G. NO CEILING PANEL TO BE CUT TO LESS THAN 6" WIDTH,
TYPICAL AT CONDITIONS WHERE CEILING PANELS EXCEED
2'-0" TRIM 2' X 4' CEILING PANELS AS REQ'D TO FIT.
H. COORDINATE THE LOCATION OF ESCUTCHEON PLATES AT
CEILING PANEL PENETRATIONS WITH ELECTRICAL AND
MECHANICAL TRADES.
REFER TO DWG AP-1.5 FOR RCP PLAN
OF CONNECTOR LEVEL (BELOW)
A5-52
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
A.3
P/R 5
21052E
P/R 4
21052D
P/R 3
21052C
P/R 2
21052B
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
9' - 6"
C.H.
7' - 2"
C.H.
7' - 2"
C.H.
A5-04
8' - 6"
C.H.
9' - 0"
C.H.
9' - 0"
C.H.
ECHO 4
21045B
PASSAGE
21044
ECHO 3
21044C
2721
CLEAN
SUPPLY
21055
P/R 8
21052H
ECHO 2
21044A
ROLLER SHADE (EA WINDOW, THIS AREA), SEE 12/A5-65
VIP PATIENT RM 01
2706
4
A2-02
3
A5-04
ISOLATION
PATIENT ROOM
C.4
2707
9' - 0"
C.H.
P/R 9
21052J
P/R 10
21052K
9' - 0"
C.H.
CORRIDOR
210Z8
NURSE
STATION
21054
8' - 6"
C.H.
12.2
12.1
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
C.J.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
ECHO 1
21040C
B
9' - 0"
C.H.
9' - 0"
C.H.
8' - 0"
C.H.
8' - 6"
C.H.
TEE 2
21049
STRESS
ECHO 4
21045A
SOILED
SCOPE/UTILITY
21047
STRESS
ECHO 3
21045
STRESS
ECHO 2
21043
CORRIDOR
210Z5
8' - 6"
C.H.
SHAFT #1
.
4
FEMALE
PHYS
LOCKERS
21095
8' - 6"
C.H.
7' - 2"
C.H.
9' - 0"
C.H.
9' - 0"
C.H.
9' - 0"
C.H.
TREADMILL
3
21076
TREADMILL
2
21075
TREADMILL
1
21074
9' - 0"
C.H.
CLG MTD POWER
SEE DETAIL 9/A5-52
9' - 0"
C.H.
DOWN LIGHT FIXTURE
FLUORESCENT FIXTURE
8' - 6"
C.H.
CORRIDOR
210Z7
9' - 0"
C.H.
HOT LAB
21062
FUTURE
SPECT / CT
21080
S
SPEAKER (GRILLE)
NURSE CALL DOME LIGHT
9' - 0"
C.H.
8' - 0"
C.H.
GAMMA
CAMERA 1
21077
GAMMA
CAMERA 2
21079
SMOKE DETECTORS
JUNCTION BOX IN CEILING
MEDS
21073
STF TLT
21098
S
8' - 6"
C.H.
7' - 2"
C.H.
8' - 6"
C.H.
MALE PHYS
LOCKERS
21096
8' - 0"
C.H.
NM OFFICE
21072
STRESS
READING
21064
CAMERA
NM
EQUIPMENT
21069
8' - 0"
C.H.
11.9
9' - 0"
C.H.
8' - 6"
C.H.
STAFF
LOUNGE
21090
SIM/TRAINING
21094
9' - 0"
C.H.
COMM
21050
8' - 0"
C.H.
9' - 0"
C.H.
9' - 0"
C.H.
8' - 0"
C.H.
C
A5-51
9' - 0"
C.H.
CLG MTD MED GAS
SEE DETAIL 8/A5-52
HSKG
21081
ELEC
21051
9' - 0" PHYS
C.H. LOUNGE
21093
RETURN AIR DIFFUSER
VENIPUNCTURE
2
21061
LINEAR DIFFUSER
FEMALE STF
LOCKERS
21099
8' - 6"
C.H.
8' - 6"
C.H.
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
STRESS
ECHO 1
21042
VENIPUNCTURE
1
21060
7' - 2" 8' - 0"
C.H.
C.H.
STF TLT
21091
7' - 2"
C.H.
STF TLT
21092
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
9' - 0"
C.H.
SUPPLY AIR DIFFUSER
P/R 11
21052L
8' - 0"
C.H.
12.5
12.4
C.H.
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
8' - 6"
C.H.
B.8
9' - 0"
C.H.
8' - 6"
C.H.
CLEAN
SCOPE
21047A
STAFF BATHROOM
2707A
1HR FIRE RESISTANCE RATED BARRIER
I.V. TRACK, SEE SHT A5-51
A5-51
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
6" CEILING EXP. JT.
TYPE 'CA-6'
2708A
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
10' - 6"
C.H.
5
8' - 0"
C.H.
BATHROOM
CEILING PLAN LEGEND
9' - 0"
C.H.
8' - 6"
C.H.
8' - 0"
C.H.
Issue
Progress Set 2
Scope Review Set
Construction Issue 12
Construction Issue 13
Construction Issue 15
CUBICLE CURTAIN TRACK, SEE SHT A5-51
TEE 1
21048
NON-INV P/R
21052
Date
12/21/11
06/27/12
07/18/12
08/08/12
01/23/13
2HR FIRE RESISTANCE RATED BARRIER
PAT TLT
21053
8' - 6"
C.H.
NW ELEV
LOBBY
210Z10
BATHROOM
REFER TO AQ-XX SERIES DRAWINGS FOR ADDITIONAL INFO
ON CEILING MOUNTED EQUIPMENT.
EQUIPMENT
21046
9' - 0"
C.H.
2
A4-501
2706A
9' - 6"
C.H.
9' - 6"
C.H.
WORKROOM
21044B
8' - 6"
C.H.
PAT TLT
21056
A.7
2722
L.
9' - 0"
C.H.
4
STORAGE
FIELD VERIFY LOCATIONS OF SOFFIT & CEILING CONTROL
JOINTS WITH THE A/E REP.
311 Mack Avenue
Detroit, Michigan 48201
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
10' - 6"
C.H.
P/R 1
21052A
8' - 0"
C.H.
BATHROOM
K.
CORRIDOR/WTG
210Z1
P/R 7
P/R 6
21052G 21052F
8' - 0"
C.H.
9' - 6"
C.H.
8' - 0"
C.H.
8' - 0"
C.H.
A.7
PAINT ALL VISIBLE, EXPOSED CONSTRUCTION ABOVE
CEILINGS INCLUDING BUT NOT LIMITED TO MECH & ELEC
ITEMS. SEE NOTES ON A6-1x SERIES DWGS FOR EXTENT.
O. GYPSUM BD CEILINGS & SOFFITS TO BE CONSTRUCTED W/
5/8" THK GYPSUM BOARD, AS INDICATED ON TYP DETAILS
OF SHT A5-51, TO COORD WITH LT FIXTURE REQUIREMENTS.
A
NE ELEV
LOBBY
210Z9
8' - 0"
C.H.
A.6
J.
N. CONTRACTOR SHALL MAINTAIN THE FIRE RATING INTEGRITY
OF ALL EXISTING PARTITIONS INDICATED AS FIRE
RESISTANCE RATED. ADVISE THE ARCHITECT OF ANY PREEXISTING BREACHES DISCOVERED IN COURSE OF WORK.
3
EX BRUSH
BLDG
SPRINKLER HEADS TO BE LOCATED IN THE CENTER OF
CEILING PANELS, UNO.
M. PATCH AND REPAIR EXISTING CEILING PANELS AND GRID
WHERE WALLS ARE REMOVED.
11.3
N STAIR
210X5
I.
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
NM
WORKROOM
21070
CONTROL
21078
STF TLT
21068
7' - 2"
C.H.
8' - 6"
C.H.
7' - 2"
C.H.
8' - 6"
C.H.
MALE STF
LOCKERS
21097
8' - 6"
C.H.
INJECTED
TLT
21067
7' - 2"
C.H.
STF TLT
21071
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
DIRECTOR
21066
9' - 0"
C.H.
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
D
5
A5-51
VIP PATIENT RM 01
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
ROLLER SHADE (EA WINDOW, THIS AREA), SEE 12/A5-65
2708
D.4
Copyright © 2011
2008
11.4
11
10
9
8
7
6
B
SECOND FLOOR REFELECTED CEILING PLAN - AREA B
Project No.
Drawn
Checked
Approved
2011-10001-000
M.J.Bednarczyk
K.Doyle
E.G.Essique
Title
Second Floor
Reflected Ceiling
Plan - Area B
SCALE: 1/8" = 1'-0"
N
3"=1'0"
8/29/2013 11:20:00
AM
0
1
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
KEYPLAN
Sheet No.
AR-2B
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
150
1"=50'
100
50
0
100
200
300
1"=100'
CEILING PLAN
GENERAL NOTES
A.
WHERE NO FINISH CEILING IS INDICATED, THE ROOM/SPACE
SHALL BE EXPOSED TO THE STRUCTURE ABOVE. REFER TO
ROOM FINISH SCHEDULE FOR FINISHING REQUIREMENTS.
B.
COORDINATE FINAL SIZE AND FINAL LOCATION OF ALL
ACCESS PANELS WITH TRADE REQUIRING SAME.
C. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER
CEILING SPACE EQUIPMENT SUPPORTING DEVICES.
D. FOR PARTITION TYPES, SEE SHEET A5-71 AND A5-72.
E.
SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND NIGHT
LIGHT LOCATIONS
F.
CEILING GRID LAYOUT - SYSTEM TO BE CENTERED IN ROOM,
IN BOTH DIRECTIONS, UNO. CEILING GRID AREAS DIVIDED BY
SOFFITS/DOORS TO BE ALIGNED. WORKPOINT MARKERS /
DIMENSIONS SHALL SUPERCEDE, WHERE PROVIDED. ASSUME
WORKPOINT STARTER PANELS TO BE FULL SIZE OR 6",
UNLESS DIMENSIONED.
G. NO CEILING PANEL TO BE CUT TO LESS THAN 6" WIDTH,
TYPICAL AT CONDITIONS WHERE CEILING PANELS EXCEED
2'-0" TRIM 2' X 4' CEILING PANELS AS REQ'D TO FIT.
H. COORDINATE THE LOCATION OF ESCUTCHEON PLATES AT
CEILING PANEL PENETRATIONS WITH ELECTRICAL AND
MECHANICAL TRADES.
B-2
B-1
2.2
I.
SPRINKLER HEADS TO BE LOCATED IN THE CENTER OF
CEILING PANELS, UNO.
J.
PAINT ALL VISIBLE, EXPOSED CONSTRUCTION ABOVE
CEILINGS INCLUDING BUT NOT LIMITED TO MECH & ELEC
ITEMS. SEE NOTES ON A6-1x SERIES DWGS FOR EXTENT.
K.
FIELD VERIFY LOCATIONS OF SOFFIT & CEILING CONTROL
JOINTS WITH THE A/E REP.
L.
REFER TO AQ-XX SERIES DRAWINGS FOR ADDITIONAL INFO
ON CEILING MOUNTED EQUIPMENT.
M. PATCH AND REPAIR EXISTING CEILING PANELS AND GRID
WHERE WALLS ARE REMOVED.
N. CONTRACTOR SHALL MAINTAIN THE FIRE RATING INTEGRITY
OF ALL EXISTING PARTITIONS INDICATED AS FIRE
RESISTANCE RATED. ADVISE THE ARCHITECT OF ANY PREEXISTING BREACHES DISCOVERED IN COURSE OF WORK.
3
A5-52
O. GYPSUM BD CEILINGS & SOFFITS TO BE CONSTRUCTED W/
5/8" THK GYPSUM BOARD, AS INDICATED ON TYP DETAILS
OF SHT A5-51, TO COORD WITH LT FIXTURE REQUIREMENTS.
A
10' - 0"
C.H.
10' - 0"
C.H.
CORRIDOR/WTG
410Z1
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
311 Mack Avenue
Detroit, Michigan 48201
Date
12/21/11
06/27/12
07/18/12
02/15/13
04/05/13
05/24/13
Issue
Progress Set 2
Scope Review Set
Construction Issue 12
Construction Issue 16
Construction Issue 17
Construction Issue 18
CEILING PLAN LEGEND
CORRIDOR/WTG
410Z1
2'-0"2'-0"
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
12' - 0"
C.H.
12' - 0"
C.H.
12' - 0"
C.H.
PAT TLT
41036
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
A.4
1HR FIRE RESISTANCE RATED BARRIER
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
CORRIDOR/WTG
410Z3
8' - 6"
C.H.
A.5
2HR FIRE RESISTANCE RATED BARRIER
CUBICLE CURTAIN TRACK, SEE SHT A5-51
P/R 18
41040C
P/R 17
41040B
P/R 16
41040A
P/R 8
41030H
P/R 7
41030G
P/R 6
41030F
PUB TLT
41015
7' - 2"
C.H.
MEDS
41035-0
P/R 5
41030E
PUB TLT
41016
7' - 2"
C.H.
I.V. TRACK, SEE SHT A5-51
RECEPT/
REG
41010
WORKROOM
41012
5
8' - 6"
C.H.
8' - 6"
C.H.
SPEC
HOLD/POC
41042
P/R 1
41030A
NOURISH
41041
8' - 6"
C.H.
P/R 28
41040P
P/R 2 ISO
41030B 8' - 6"
C.H.
7' - 2"
C.H.
STF TLT
41056
6'-6"
C.H.
P/R 3
41030C
ANES
WORKROOM
41054
TRACKING
ALCOVE
41065
C.J.
9' - 0"
C.H.
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
B.2
CORRIDOR
410Z4
CONF/TRAINING
41013
PAT TLT
41031
8' - 6"
C.H.
9' - 6"
C.H.
B.6
9' - 6"
C.H.
RETURN AIR DIFFUSER
8' - 6"
C.H.
STERILE
STORAGE
41059
B.7
C.J.
ELEC
41021
COMM
41020
LINEAR DIFFUSER
C.J.
CLG MTD MED GAS
SEE DETAIL 8/A5-52
12' - 0"
C.H.
STF TLT
41060
CLG MTD POWER
SEE DETAIL 9/A5-52
C.J.
HSKG
41017
DOWN LIGHT FIXTURE
C
S ELEV 1
-
FLUORESCENT FIXTURE
2
A5-52
SCRUB 5-6
41063
CRASH
CART
ALCOVE
41065A
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
B
EQUIP
41061
CLEAN
SUPPLY
41058
9' - 0"
C.H.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
SUPPLY AIR DIFFUSER
P/R 4
41030D
SHAFT #6
-
C.J.
A.9
A5-51
8' - 6"
C.H.
REFER TO DWG A9-61
FOR ALT. #6 FIT-OUT
9' - 6"
C.H.
SOILED
UTILITY
41057
CONTROL
STATION
41055
10' - 0"
C.H.
CONSULT
41011
3
SHELLED S
SURG P/R
41030-0
NURSE
STATION
41030K
SOILED
UTILITY
41034
8' - 6"
C.H.
P/R 29
41040Q
8' - 6"
C.H.
CLEAN
SUPPLY
41033
UNIT SEC
41043
8' - 6"
C.H.
P/R 30
41040R
8' - 6"
C.H.
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
9' - 0"
C.H.
A5-51
9' - 6"
C.H.
GOWN/WARMER
ALCOVE
7' - 2"
41030J
C.H.
C.H.
8' - 6"
C.H.
A/V CLOSET
41082
SHAFT #7
-
SMOKE DETECTORS
S
SPEAKER (GRILLE)
C.3
C.J.
S ELEV 2
-
S
NURSE CALL DOME LIGHT
JUNCTION BOX IN CEILING
11' - 0"
C.H.
CAMERA
DECON
41079
9' - 0"
C.H.
A5-72
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
FUTURE S
ELEV 4
-
FLASH
STERILE
41080
9' - 0"
C.H.
S ELEV
LOBBY
410Z2
10' - 0"
C.H.
SCOPE
CLEAN
41079A
REFER TO DWG A9-62
FOR O.R. 6 FIT-OUT
OR 5
41081
C.J.
14
TYP OVER
LENGTH OF
STAIR PASSAGE
S ELEV 3
-
FUTURE OR
7/8
41025
OR 6
41083-0
D
C.J.
EQUIP
41078
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
D.1
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
12
A4-501
M
D.4
D.5
Copyright © 2011
2008
6
5
4
3
2
1.8
1.5
1.2
1.1
1
A
FOURTH FLOOR REFLECTED CEILING PLAN - AREA A
Project No.
Drawn
Checked
Approved
2011-10001-000
M.J.Bednarczyk
K.Doyle
E.G.Essique
Title
Fourth Floor
Reflected Ceiling
Plan - Area A
SCALE: 1/8" = 1'-0"
N
3"=1'0"
8/29/2013 11:20:27
AM
0
1
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
KEYPLAN
Sheet No.
AR-4A
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
150
1"=50'
100
50
0
100
200
300
1"=100'
CEILING PLAN
GENERAL NOTES
A.
WHERE NO FINISH CEILING IS INDICATED, THE ROOM/SPACE
SHALL BE EXPOSED TO THE STRUCTURE ABOVE. REFER TO
ROOM FINISH SCHEDULE FOR FINISHING REQUIREMENTS.
B.
COORDINATE FINAL SIZE AND FINAL LOCATION OF ALL
ACCESS PANELS WITH TRADE REQUIRING SAME.
C. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER
CEILING SPACE EQUIPMENT SUPPORTING DEVICES.
D. FOR PARTITION TYPES, SEE SHEET A5-71 AND A5-72.
E.
SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND NIGHT
LIGHT LOCATIONS
F.
CEILING GRID LAYOUT - SYSTEM TO BE CENTERED IN ROOM,
IN BOTH DIRECTIONS, UNO. CEILING GRID AREAS DIVIDED BY
SOFFITS/DOORS TO BE ALIGNED. WORKPOINT MARKERS /
DIMENSIONS SHALL SUPERCEDE, WHERE PROVIDED. ASSUME
WORKPOINT STARTER PANELS TO BE FULL SIZE OR 6",
UNLESS DIMENSIONED.
G. NO CEILING PANEL TO BE CUT TO LESS THAN 6" WIDTH,
TYPICAL AT CONDITIONS WHERE CEILING PANELS EXCEED
2'-0" TRIM 2' X 4' CEILING PANELS AS REQ'D TO FIT.
H. COORDINATE THE LOCATION OF ESCUTCHEON PLATES AT
CEILING PANEL PENETRATIONS WITH ELECTRICAL AND
MECHANICAL TRADES.
I.
SPRINKLER HEADS TO BE LOCATED IN THE CENTER OF
CEILING PANELS, UNO.
J.
PAINT ALL VISIBLE, EXPOSED CONSTRUCTION ABOVE
CEILINGS INCLUDING BUT NOT LIMITED TO MECH & ELEC
ITEMS. SEE NOTES ON A6-1x SERIES DWGS FOR EXTENT.
K.
FIELD VERIFY LOCATIONS OF SOFFIT & CEILING CONTROL
JOINTS WITH THE A/E REP.
L.
REFER TO AQ-XX SERIES DRAWINGS FOR ADDITIONAL INFO
ON CEILING MOUNTED EQUIPMENT.
M. PATCH AND REPAIR EXISTING CEILING PANELS AND GRID
WHERE WALLS ARE REMOVED.
N. CONTRACTOR SHALL MAINTAIN THE FIRE RATING INTEGRITY
OF ALL EXISTING PARTITIONS INDICATED AS FIRE
RESISTANCE RATED. ADVISE THE ARCHITECT OF ANY PREEXISTING BREACHES DISCOVERED IN COURSE OF WORK.
3
A5-52
O. GYPSUM BD CEILINGS & SOFFITS TO BE CONSTRUCTED W/
5/8" THK GYPSUM BOARD, AS INDICATED ON TYP DETAILS
OF SHT A5-51, TO COORD WITH LT FIXTURE REQUIREMENTS.
A
NE ELEV
LOBBY
410Z9
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
10' - 0"
C.H.
2'-0"
N STAIR
410X5
10' - 0"
C.H.
CORRIDOR/WTG
410Z1
2'-0"
A.3
NURSE MGR
41097
FUTURE N
ELEV 2
-
N ELEV 3
SERVICE
-
N ELEV 4
PUBLIC
-
MED GAS
STOR
41098
A.7
CLINICAL
COORD
41096
8' - 6"
C.H.
8' - 6"
C.H.
PUB TLT
41094
PUB TLT
41093
8' - 0"
C.H.
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
7' - 2"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
8' - 6"
C.H.
P/R 23
41040H
P/R 22
41040G
P/R 21
41040F
P/R 18
41040C
P/R 19
41040D
SUPPLY
COORD
41087
8' - 6"
C.H.
MEDS
41047
MALE
LOCKERS
41086
MALE TLT
41086A
P/R 24
8' - 6" 41040J
C.H.
STF
LOUNGE
41092
PHYS
LOUNGE
41091
7' - 2"
C.H.
8' - 0"
C.H.
B.8
FEMALE
LOCKERS
41089
FEMALE TLT
41089A
C.J.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
CLEAN
CART
41069
UNIT SEC
41043
8' - 6"
C.H.
P/R 30
41040R
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
SPEC
HOLD/POC
41042
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
SUPPLY AIR DIFFUSER
P/R 27
41040N
PAT TLT
41044
8' - 6"
C.H.
8' - 6"
C.H.
CLEAN
SUPPLY
41046
COMM
41050
ELEC
41051
P/R 28
41040P
P/R 29
41040Q
STERILE
STORAGE
41052
CHARTING
41040M
SHAFT #5
-
8' - 6"
C.H.
RETURN AIR DIFFUSER
STF TLT
41056
6'-6"
C.H.
ANES
WORKROOM
41054
STF TLT
41053
LINEAR DIFFUSER
CONTROL
STATION
41055
CLG MTD MED GAS
SEE DETAIL 8/A5-52
CLG MTD POWER
SEE DETAIL 9/A5-52
DOWN LIGHT FIXTURE
C
HSKG
41090
A5-51
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
7' - 2"
C.H.
8' - 0"
C.H.
6
8' - 0"
C.H.
8' - 6"
C.H.
APPROX
9' - 8"
C.H.
SHAFT #4
-
7' - 2"
C.H.
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
B
8' - 6"
C.H.
7' - 2"
C.H.
PASSAGE
41084
C.H.
8' - 6"
C.H.
P/R 26
41040L
9' - 0"
C.H.
8' - 6"
C.H.
9' - 6"
C.H.
P/R 25
41040K
9' - 0"
C.H.
STAFF
SHOWER
41085
SOILED
UTILITY
41045
8' - 6"
C.H.
6
A5-51
P/R 16
41040A
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
GOWN/WARMER
ALCOVE
41040T
7' - 2"
C.H.
8' - 0"
C.H.
8' - 0"
C.H.
B.1
7' - 2"
C.H.
P/R 17
41040B
A5-51
9' - 6"
C.H.
7' - 2"
C.H.
2HR FIRE RESISTANCE RATED BARRIER
5
NW ELEV
LOBBY
410Z10
11.3
8' - 6"
C.H.
CUBICLE CURTAIN TRACK, SEE SHT A5-51
P/R 20
41040E
3
A4-501
GOWN
VENDING
41088
8' - 6"
C.H.
I.V. TRACK, SEE SHT A5-51
8' - 6"
C.H.
CORRIDOR
410Z6
8' - 6"
C.H.
Issue
Progress Set 2
Scope Review Set
Construction Issue 12
Construction Issue 16
Construction Issue 18
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
PAT TLT
41048
8' - 6"
C.H.
Date
12/21/11
06/27/12
07/18/12
02/15/13
05/24/13
1HR FIRE RESISTANCE RATED BARRIER
SOILED
UTILITY
41049
MED
DIRECTOR
41095
311 Mack Avenue
Detroit, Michigan 48201
CEILING PLAN LEGEND
10' - 0"
C.H.
2'-0"2'-0"
12' - 0"
C.H.
M
N ELEV 1
PATIENTA.6
-
10' - 0"
C.H.
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
FLUORESCENT FIXTURE
C-ARM
ALCOVE
41068
COORDINATE CUT PANEL
W/ LIGHTING LOCATION
& TLT. COMP.
SCRUB 1-2
41067
8' - 6"
C.H.
9' - 0"
C.H.
SCRUB 3-4
41066
A/V CLOSET
41073
C.4
CORRIDOR
410Z5
CRASH
CART
ALCOVE
41065A
9' - 0"
C.H.
A/V CLOSET
41076
S
SMOKE DETECTORS
S
SPEAKER (GRILLE)
NURSE CALL DOME LIGHT
JUNCTION BOX IN CEILING
8' - 0"
C.H.
CAMERA
12.5
12.4
12.2
12.1
EQUIP
41078
SOILED
CART
41070
11.9
DECON
41079
9' - 0"
C.H.
14
CLEAN
CART
LARGE
41071
10
A4-501
SHELLED
OR 1
41072
TYP OVER
LENGTH OF
STAIR PASSAGE
A5-72
10' - 0"
C.H.
OR 2
41074
10' - 0"
C.H.
10' - 0"
C.H.
OR 3
41075
FIT-OUT O.R. 6 IN LIEU OF O.R. 1,
REFER TO DWG A9-62, RM INFO
REMAINS FOR REFERENCE ONLY
9' - 0"
C.H.
OR 4
41077
11
A4-501
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
SCOPE
CLEAN
41079A
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
D
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
M
D.4
PROVIDE NO CEILING IN ROOM
Copyright © 2011
2008
11.4
11
10
9
8
7
6
B
FOURTH FLOOR REFLECTED CEILING PLAN - AREA B
SCALE: 1/8" = 1'-0"
N
N
3"=1'0"
8/29/2013 11:20:53
AM
0
1
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
KEYPLAN
Project No.
Drawn
Checked
Approved
2011-10001-000
M.J.Bednarczyk
K.Doyle
E.G.Essique
Title
Fourth Floor
Reflected Ceiling
Plan - Area B
Sheet No.
AR-4B
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
15
10
5
0
10
20
30
30
1"=10'
20
10
0
20
40
60
45
1"=20'
30
15
0
30
60
90
60
1"=30'
40
20
0
40
80
120
75
1"=40'
50
25
0
50
100
150
150
1"=50'
100
50
0
100
200
300
1"=100'
ENLARGED O.R. CLG
PLAN NOTES:
C.J.
7' - 0 7/8"
9' - 1 1/8"
7' - 0 7/8"
7' - 0 7/8"
7' - 0 7/8"
9' - 1 1/8"
C.J.
C.J.
REFER TO SHT A5-75
FOR A/V CLOSET CLG
CLG MTD LIGHT
FIXTURES (TYP)
C.J.
C.J.
7' - 0 7/8"
C.J.
ACCESS PANEL TYP.
1. SEE EQUIPMENT
PLANS FOR MOUNT
LOCATIONS & STRUC
SUPPORT TYPE.
2. SEE 10/A5-52 FOR
TYPICAL EQUIP DETAIL
@ CLG PLANE.
3. * = CRIT ENV CLG C/L
TO C/L DIMENSION.
4. GYP BD CLG OPENING
TO BE * PLUS 3/4".
SINGLE
MOUNT:
SURG LT
FLAT PANEL
CLG MTD HVAC
DIFFUSER (TYP)
FUTURE SINGLE
MOUNT: SURG LT
(PROVIDE SOLID
INFILL CLG PANEL,
PROVIDE STRUC
SUPPORT - ABOVE)
16'-2" *
9' - 1 1/8"
7' - 0 7/8"
EMER LT FIXT
IN CLG PANEL
CEILING CJ'S
CLARIFIED IN
PRE-AWARD
RFI 083 RESPONSE
OR 5
41081
C.J.
2' - 8 1/4"
16'-2" *
TANDEM
MOUNT:
EQUIP BOOM
SURG LT
FLAT PANEL
OR 4
41077
C.J.
C.J.
10' - 0"
C.H.
REFER TO TYP. O.R. 10/A4-501
FOR TYP CEILING LAYOUT NOTES
311 Mack Avenue
Detroit, Michigan 48201
C.J.
10' - 0"
C.H.
D
D
CLG
MOUNTED
SPEAKER
(TYP FOR 2)
REFER TO TYP. O.R. 10/A4-501
FOR TYP CEILING LAYOUT NOTES
CEILING CJ'S CLARIFIED IN
PRE-AWARD RFI 083 RESPONSE
O.R. 5 ENLARGED REFLECTED CEILING PLAN
12
AR-4A
CRITICAL
ENVIRONMENT
CEILING (ACT-10),
SEE 1/A5-52
SHELLED
OR 1
41072
C.J.
C.J.
D
5
2' - 8 1/4"
Cardiovascular
Institute &
Harper-Hutzel
Specialty Center
CEILING SYSTEM
ACCESS PANEL
TYP.
9' - 1 1/8"
2' - 8 1/4"
SINGLE
MOUNT:
ANES
BOOM
9' - 1 1/8"
9' - 1 1/8"
TABLE CENTER
LAYOUT BENCHMARK
11
AR-4B
SCALE: 1/4" = 1'-0"
CEILING CJ'S CLARIFIED IN
PRE-AWARD RFI 083 RESPONSE
9
TYP O.R. 3 & 4 ENLARGED REFLECTED CEILING
PLAN
10
AR-4A
SCALE: 1/4" = 1'-0"
TYP O.R. 1 & 2 ENLARGED REFLECTED CEILING
PLAN
Date
06/27/12
07/18/12
08/08/12
02/15/13
SCALE: 1/4" = 1'-0"
1.8
Issue
Scope Review Set
Construction Issue 12
Construction Issue 13
Construction Issue 16
B.6
B.7
1
A4-10
T
REFER TO AR-x SERIES
DRAWINGS FOR RELATED PLAN
GENERAL NOTES AND KEYNOTES.
CEILING PLAN LEGEND
C
REFER TO DWG A5-5x SERIES FOR CEILING DETAILS
1
SMOKE BARRIER - 1 HR FIRE RESISTANCE
RATED (UNLESS ACCOMPANIED BY
HIGHER DESIGNATION)
A5-04
1HR FIRE RESISTANCE RATED BARRIER
2HR FIRE RESISTANCE RATED BARRIER
CUBICLE CURTAIN TRACK, SEE SHT A5-51
I.V. TRACK, SEE SHT A5-51
C.3
3
C.H.
ELEVATION OF FINISH CEILING AFF (8'-0" UNO)
C.J.
GYPSUM BOARD CONTROL JOINT,
SEE SHT A5-71
A4-10
GYPSUM BOARD CEILING ON MTL FRAMING
ELEVATION AS NOTED. COORD ELEV OF
GYPSUM BD SOFFITS ABOVE CABINETS
WITH A4-3XX SERIES, A5-81, & A5-82 DWGS.
ACOUSTIC LAY-IN CEILING PANEL, TYPE
AS SCHEDULED ON A6-1x SERIES
WOOD VENEER LAY-IN CEILING PANEL,
ACT-2 AS SCHEDULED ON A6-1x SERIES
TYP
2
PATTERN INDICATES FIELD CUT
PANEL/GRID BASED ON FIELD
CONDITIONS. CUT PANELS
FROM 2x4 CEILING PANELS (TYPICAL)
A5-52
SUPPLY AIR DIFFUSER
CONT COVE LT
FIXTS, SEE SECTION
RETURN AIR DIFFUSER
LINEAR DIFFUSER
CLG MTD MED GAS
SEE DETAIL 8/A5-52
CLG MTD POWER
SEE DETAIL 9/A5-52
DOWN LIGHT FIXTURE
26913 Northwestern Hwy
Suite 200
Southfield, Michigan
48033-3476 | USA
FLUORESCENT FIXTURE
S
SMOKE DETECTORS
S
SPEAKER (GRILLE)
D
D.1
(tel) (248) 262.1500
(fax) (248) 262.1515
harleyellisdevereaux.com
NURSE CALL DOME LIGHT
JUNCTION BOX IN CEILING
CAMERA
1.5
4
.
HOLD
6" TO INSIDE
FACE OF CURTAIN
WALL @ 1ST & 2ND,
EXT WALL @ 4TH
8'-0"
CLERESTORY, SEE
DET. 17/A5-65
FP SPRINKLER HEAD
4
A5-52
DROPPED
ACOUSTIC CLG
LT FIXT
ACOUSTIC CLG
GYP BD SOFFIT
EQUAL
1" CLR
PROVIDE
INTERMEDIATE
GRID AS REQ'D
FOR DIFFUSER
FP SPRINKLER HEAD
FP SPRINKLER HEAD
SUPPLY DIFFUSER
SUPPLY DIFFUSER
SUPPLY DIFFUSER
LIGHT FIXTURE, TYP.
LIGHT FIXTURE, TYP.
M
48" LG I.V. TRACK, TYP
TV
LAY-IN CLG.
LIGHT FIXTURE, TYP.
LAY-IN CLG.
LAY-IN CLG.
8' - 0"
C.H.
8' - 6"
C.H.
1" CLR
GYP. BD. SOFFIT
GYP. BD. SOFFIT
CUBICLE CURTAIN TRACK
8' - 0"
C.H.
GYP. BD. SOFFIT
1" CLR
CUBICLE CURTAIN TRACK
Project No.
Drawn
Checked
Approved
2011-10001-000
KCade
K.Doyle
E.G.Essique
Title
Enlarged Reflected
Ceiling Plans
CUBICLE CURTAIN TRACK
3
5
TYP
3"=1'0"
8/29/2013 11:16:46
AM
8' - 6"
C.H.
8' - 6"
C.H.
4"
4
HEAD LIGHT FIXTURE
2'-0"
HEAD LIGHT FIXTURE
8' - 6"
C.H.
CLERESTORY, SEE
DET. 17/A5-65
HEAD LIGHT FIXTURE
1" CLR
A5-52
CLERESTORY, SEE
DET. 17/A5-65
TV
PROVIDE CUT CLG
PANELS EA SIDE OF
CENTERED DIFFUSER,
ORIENT MAIN SUSPENSION MEMBERS
AS NECESSARY
J
4
ALIGN, TYP
Copyright © 2011
2008
COORD
ALIGN, TYP
SCALE: 1/4" = 1'-0"
F
A5-52
22'-0" (COORD FULL PANELS)
TYPICAL ELEVATOR LOBBY
.2"-0"
3
EQUAL
TYP
Planning
Architecture
Engineering
Interior Architecture
Landscape Architecture
Construction Services
1.2
0
3
A9-61
TYPICAL CORRIDOR/WTG
TYP P/R REFLECTED CEILING PLAN-4th FLOOR
2
AR-2A
SCALE: 1/4" = 1'-0"
TYP P/R REFLECTED CEILING PLAN -2nd FLOOR
SCALE: 1/4" = 1'-0"
1
A9-31
10
TYP P/R REFLECTED CEILING PLAN-1st FLOOR
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
Sheet No.
1
1-1/2"=1'0"
1
0
1
2
3/4"=1'0"
2
1
0
2
4
1/4"=1'0"
1/8"=1'0"
8
4
0
5
10
A4-501
1/16"=1'0"
6
0
10
20
30
12
0
20
40
C:\Revit60Local\CQO_Arch_Model_kpdoyle_local.rvt
Download