Multitaps MTE-8+/N • 8-way tap • Cenelec Class A screening effectiveness • NiSn plated housing, silver plated phosphor bronze F-contacts • High return loss • Excellent intermodulation distance, ModemSafe secured • SCTE compliant F-connectors • Easy to install: compact and top-sided model Overview The Ecoline+ series of Splitters & Taps have been especially developed to meet the needs of the European market and distinguishes itself from any other range in the business. With the Ecoline+ a new standard of splitters and taps has been set fully equipped with a number of innovative technologies. The products within the Ecoline range excel both in electrical and mechanical performance. It is a really complete series, containing all housing types that could be found in the previous Ecoline and Ruby-line series. It has an easy to install design with a compact housing of which some models are stackable. All F-connector contacts meet the SCTE standards (ANSI SP 406-1998) and are of unequalled quality. The material of the inner spring has been designed specially for connecting coax cables with an inner core of 0.56 to 1.30 mm, even when varying thicknesses are connected after each other. The intermodulation performance, which is an important factor in high level return path signals, has been greatly improved through a newly developed ferrite and specially designed circuits. The high frequency shielding exceeds Class A requirements (CENELEC EN-50083-2:1998) over the whole frequency range from 5 MHz to 1000 MHz. Sep/2013 - Version final 1.0 Modem Safe Modem Safe is a highly effective surge protection solution for sensitive network and in-home CPE. Based on passive circuits, the technology does not rely on discharge tubes, extending the lifespan of the solution. • Blocks high and low voltage pulses and unwanted DC voltages • Prevents internal ferrites within the product from becoming magnetised (avoiding deterioration in the performance of CPE) • Drives fewer reported faults • Improves customer service • Reduces truck rolls CPD Safe CPD (Common Path Distortion) is well known for producing signal interference on networks. It is caused by electrolytic corrosion or the oxidisation of dissimilar metals when in close contact. CPD Safe technology protects against CPD. • Removes a primary cause of CPD • Reduces signal interference on the network • Drives fewer reported faults • Reduces truck rolls • Improves customer service Technetix Group Limited e: sales@technetix.com w: www.technetix.com Multitaps MTE-8+/N Specifications Insertion Loss (dB) Tap Loss In -> Out In -> Tap 1 In -> Tap 2 In -> Tap 3 In -> Tap 4 In -> Tap 5 In -> Tap 6 In -> Tap 7 In -> Tap 8 Return Loss (dB, min) In/Out/Tap Screening efficiency (dB)1 MHz Typ Max 5 - 40 8.0 9.5 40 - 862 8.0 8.5 MHz Isolation (dB, min) 5 - 10 36.0 10 - 862 40.0 862 - 1000 30.0 5 - 10 24.0 862 - 1000 8.5 9.0 5 - 10 12.5 14.0 10 - 862 12.5 13.5 10 - 862 23.5 862 - 1000 12.5 13.7 862 - 1000 23.7 5 - 10 13.5 15.0 5 - 10 25.0 10 - 862 13.5 14.5 10 - 862 24.5 862 - 1000 13.5 14.7 862 - 1000 24.7 5 - 10 14.5 16.0 5 - 10 25.0 10 - 862 14.5 15.5 10 - 862 24.5 862 - 1000 14.5 15.7 862 - 1000 24.7 5 - 10 15.5 17.0 5 - 10 27.0 10 - 862 15.5 16.5 10 - 862 26.5 862 - 1000 15.5 16.7 862 - 1000 26.7 5 - 10 16.5 18.0 5 - 10 28.0 10 - 862 16.5 17.5 10 - 862 27.5 862 - 1000 16.5 17.7 862 - 1000 27.7 5 - 10 17.5 19.0 5 - 10 29.0 10 - 862 17.5 18.5 10 - 862 28.5 862 - 1000 17.5 18.7 862 - 1000 28.7 5 - 10 18.5 20.0 5 - 10 30.0 10 - 862 18.5 19.5 10 - 862 29.5 862 - 1000 18.5 19.7 862 - 1000 29.7 5 - 10 19.5 21.0 5 - 10 31.0 10 - 862 19.5 20.5 10 - 862 30.5 862 - 1000 19.5 20.7 862 - 1000 30.7 Out -> Tap 1 Out -> Tap 2 Out -> Tap 3 Out -> Tap 4 Out -> Tap 5 Out -> Tap 6 Out -> Tap 7 Out -> Tap 8 5 - 10 20.0 10 - 862 22.0 Intermodulation p+q (dBc,min) 2 All ports DC blocked 862 - 1000 14.0 Surge Class conformance3 All ports 5 - 300 95.0 Connectors In/Out/Tap 300 - 470 90.0 Material 470 - 950 85.0 Housing F-spring NiSn plated zinc die-cast Silver plated phosphor bronze 950 - 1000 65.0 Dimensions (mm) LxHxD 132.3x49.2x37.9 Equipment Approval CE Remarks 1 Tested according to EN 50083-2 2006 2 Tested according to SCTE IPS-TP-403 3 Two carriers (50 & 55MHz),out to in, @ 120dBµV, after 10 pulses (25V/1,2µS rise time/500µS duration) at all ports -115 1 kV 1.2/50 µs F-female Impedance (Ohm, typ) Two carriers (50 & 55MHz), out to in, @ 120dBµV, after 1 pulse 1KV (1,2µS risetime/50µS fall time) at Input. 4 Tap -> Tap 75 Ordering information Item Name Article number MTE-8+/N 10430409 Tested according to IEC 61000-4-5 2005 © Copyright 2013 Technetix Group Limited. All rights reserved. This document is for information only. Features and specifications are subject to change without notice. Technetix, the Technetix logo, Ingress Safe, Modem Safe and certain other marks and logos are trade marks or registered trade marks of Technetix Group Limited in the UK and certain other countries. Other brand and company names are trade marks of their respective owners. Technetix protects its technology and designs by registering patents, trade marks and designs in Europe and certain other countries. Sep/2013 - Version final 1.0 Technetix Group Limited e: sales@technetix.com w: www.technetix.com