KG Technologies K106 Latching Relay Data Sheet

advertisement
K106
World Class Switching Solutions for Energy Management
Miniature HIgh-Power
Latching Relay
» 16A switching capability
» High inrush peak current 170A
» Outline dimensions: (29.0x13.0x15.7) mm
» RoHS compliant
Contact Data
Characteristics
Click here for glossary of terms
Click here for glossary of terms
Rated load
16A/20A 250Vac
Insulation resistance
Contact form
1A, 1B or 1C
Dielectric strength:
1,000 MΩ (at 500Vdc)
Max. switching voltage
277Vac
Coil to contact
4,400 Vac for 1 min.
Max. switching current
16A
Across open contacts
1,000 Vac for 1 min.
Max. switching power
4,432VA
Dielectric creepage
8mm
Electrical endurance
100,000 cycles
Ambient temperature
-40°C to +85°C
Mechanical endurance
5,000,000 cycles
Ambient humidity
85% RH, +40°C
Vibration
1.5mm (DA), 10 to 55Hz
Shock resistance:
Functional*
10G
Destructive
100G
Unit weight
Approx. 13g
TerminationPCB
Construction
Wash tight
* Unit may change state but is still functional.
Coil Data
Click here for glossary of terms
Single Coil (Latching)
Coil Consumption
Dual Coil (Latching)
400mW600mW
50ms min.
Pulse Duration
50ms min.
Coil Resistance (Ω ± 10%) @ 23°C
Nominal Coil Voltage
Min. Operating Voltage
Max. Operating Voltage
Single Coil (Latching)
Dual Coil (Latching)
3Vdc
2.4Vdc
3.9Vdc
22.5Ω
2 x 15Ω
5Vdc
4.0Vdc
7.5Vdc
62.5Ω
2 x 42Ω
6Vdc
4.8Vdc
9Vdc
90Ω
2 x 60Ω
9Vdc
7.2Vdc
13.5Vdc
202.5Ω
2 x 101.25Ω
12Vdc
9.6Vdc
18Vdc
360Ω
2 x 240Ω
24Vdc
19.2Vdc
36Vdc
1440Ω
2 x 886Ω
48Vdc
38.4Vdc
72Vdc
5760Ω
2 x 2880Ω
KG Technologies, Inc. / Phone: +1.888.513.1874 /
Fax: +1.888.511.3989 /
Email: info@kgtechnologies.net
/ Web: www.kgtechnologies.net
062015
K106
Page 2 of 4
Ordering Information
Relay Series:
Version: K106
– 1
012 P – 1A
T– Y
1: 5mm pin spacing
2: 3.5 mm pin spacing
3: 2.5 mm pin spacing
Coil Type: S: Single coil
D: Double coil
Coil Voltage1:
3, 5, 6, 9, 12, 24, 48 Vdc
Coil Polarity:
P: Positive
N: Negative
Contact Form:
1A: Form 1A – NO
1B: Form 1B – NC
1C: Form 1C
Contact Material:
T: AgSnO2
Sealed/Non-Sealed:
Y:Sealed
Z: Flux proofed
1
D
Coil voltage should be indicated in three digit format (6Vdc = 006)
Dimensional Drawings
All dimensions in mm unless otherwise noted. For more information, please contact KG Technologies.
K106
13.0
15.7
3X 1.0 ± 0.04
3X 0.5 ± 0.04
29.0
THIS TERMINAL
REMOVED FOR
FORM 1A, FORM 1B
3X 0.5 ± 0.04
3X 0.5 ± 0.04
THIS TERMINAL
REMOVED FOR
SINGLE COIL
KG Technologies, Inc. / Phone: +1.888.513.1874 /
Fax: +1.888.511.3989 /
Email: info@kgtechnologies.net
/ Web: www.kgtechnologies.net
062015
K106
Page 3 of 4
Dimensional Drawings
All dimensions in mm unless otherwise noted. For more information, please contact KG Technologies.
Single Coil, Form 1A, Form 1B
Wiring Diagrams
Single Coil, Form 1C
Dual Coil, Form 1A, Form 1B
Dual Coil, Form 1C
Version 1, PCB Layout (Bottom View)
Version 1, PCB Layout (Bottom View)
Form 1A, Form Form
1B
1A, Form 1B
Form 1C
Form 1C
5.0
5.0
20.3
Pin 1
5.0
20.3
Pin 1
3.75
3.75
7.5
7.5
SCALE 2:1
KG Technologies, Inc. / Phone: +1.888.513.1874 /
Fax: +1.888.511.3989 /
Email: info@kgtechnologies.net
/ Web: www.kgtechnologies.net
062015
K106
Page 4 of 4
Wiring Diagrams
Positive Polarity
Negative Polarity
Single Coil, Form 1A
4
3
4
3
1 (+) 2 (-) 1 (-) 2 (+)
Single Coil, Form 1B
4
3
4
3
Single Coil, Form 1C
6
3
4
6
4
3
4
4
3
1 (-) 5 (+) 5 (+) 2 (-)
Dual Coil, Form 1B
1 (-) 2 (+) 1 (+) 2 (-)
4
Single Coil, Form 1A
Dual Coil, Form 1A
4
3
4
3
5 (+) 2 (-) 1 (-) 5 (+)
1 (+) 2 (-) 1 (-) 2 (+)
4
6
3
4
6
4
3
1 (-) 2 (+) 1 (+) 2 (-)
Single Coil, Form 1B
4
3
4
3
3
1 (+) 2 (-) 1 (-) 2 (+)
4
6
1 (-) 5 (+) 5 (+) 2 (-)
3
4
6
4
3
4
3
1 (+) 5 (-) 5 (-) 2 (+)
Dual Coil, Form 1B
Single Coil, Form 1C
Dual Coil, Form 1C
3
3
Dual Coil, Form 1A
4
3
4
3
5 (-) 2 (+) 1 (+) 5 (-)
Dual Coil, Form 1C
3
1 (-) 2 (+) 1 (+) 2 (-)
4
6
3
4
6
3
1 (+) 5 (-) 5 (-) 2 (+)
Application Notes
1: It is possible that during transit or final assembly the relay could change state. Therefore, it is recommended that all relays be set
to the desired state via a power supply.
2: In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated voltage. The pulse width should
be 50ms minimum to ensure a proper change of state. DO NOT energize both T1 and T2 at the same time on a Dual Coil or energize
the coil for longer than 1 minute (damage to the coil could incur).
3: For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net.
Disclaimer: This data sheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict
every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our
engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified
parameters given in this data sheet.
KG Technologies, Inc. / Phone: +1.888.513.1874 /
Fax: +1.888.511.3989 /
Email: info@kgtechnologies.net
/ Web: www.kgtechnologies.net