a2 noted plan - Protected Harbor, Inc.

advertisement
FIRE
EXTINGUISHER
106
120
FLUSH
LANDING
LAV
PULL DOWN
LADDER
ATTIC ACCESS
SHOWER
HEAD W/
CONTROLS
9'4" CLG.
ELECTRIC
PANELS
EQUIP.
TUB
W.H.
BEDROOM #2A
9'4" CLG.
ATTIC
ACCESS
9'4" CLG.
A/H
1'-4"
EGRESS
108
117
1'-4"
8'-2"
R-11 INSULATION
CLOSET
EGRESS
ROD & SHELF
143
R-11 INSULATION
BEDROOM #3B
BEDROOM #2B
W4
9'4" CLG.
CLOSET
9'4" CLG.
9'4" CLG.
EGRESS
1'RISER
EGRESS
102
101
15' CLG.
No.
ELECTRIC
METER
9'4" CLG.
102
RAMP UP 6"
INTERIOR WALL TYPES
PROVIDE BLOCKING AS
REQUIRED TO
ACCOMMODATE FUTURE
GRAB BAR INSTALLATION
W4
54" MIN.
1'-0"
36" MIN.
24" MIN. 12" MIN.
42" MIN.
6" MAX
119
CONCRETE BLOCK
COLUMN. SEE
STRUCTURAL DRAWINGS
CONCRETE BEAM
FURRED OUT TO MATCH
COLUMN WIDTH. SEE
STRUCTURAL DRAWINGS
CONCRETE
SIDEWALK
CONCRETE BLOCK
COLUMN. SEE
STRUCTURAL
DRAWINGS
(a)
(b)
SIDE WALL
BACK WALL
HANDICAP ACCESSIBLE
GRAB BAR DETAILS
SCALE: 1/4" = 1'-0"
AREA SUMMARY
DOOR 106 BETWEEN GARAGE AND LIVING SPACE
TO BE 20 MINUTE RATED OR 1 3/8" THICK SOLID
WOOD OR 1 3/8" THICK METAL DOOR.
MAIN LIVING A/C
GARAGE
ENTRY
5,278 S.F.
568 S.F.
143 S.F.
GRAND TOTAL
5,989 S.F.
11" MIN.
17" MIN.
29" MIN.
TOE
CLEARANCE
27" MIN.
8" MIN.
9" MIN.
ALL UNPROTECTED DRS. & WINDOWS
TO BE RATED & LABELED FOR
MAX. REQUIRED WINDLOADS.
COORDINATION OF CONSTRUCTION, INCLUDING
VERIFICATION OF DIMENSIONS & FIELD CONDITIONS,
IS THE RESPONSIBILITY OF THE CONTRACTOR.
ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE DESIGN FIRM PRIOR TO CONSTRUCTION.
TRAP
WRAP
FIRST FLOOR
38" MAX.
NOTE:
ALL WINDOWS AND DOORS TO BE PGT
(SEE BUILDER FOR DETAILS)
33" - 36"
18"
1
A-7
19" min
17" - 19"
CONCRETE BEAM
FURRED OUT TO MATCH
COLUMN WIDTH. SEE
STRUCTURAL
DRAWINGS
EGRESS
33" - 36"
1'-3"
118
ACCESSIBILITY GUIDELINES PER FLORIDA
BUILDING CODE AND FAIR HOUSING ACT ARE
REQUIRED IN THIS FACILITY AND ARE MET BY
THESE PLANS. REQUIRED CLEARANCES IN
KITCHENS, ALL BATHROOMS AND LAUNDRY
ROOM SHALL MEET MINIMUMS AS PER THE
ATTACHED SHEET A8. USABLE DOORS AND AN
ACCESSIBLE ROUTE INTO AND THROUGH THE
BUILDING HAVE BEEN PROVIDED. BLOCKING IN
BATH WALLS SHALL BE INSTALLED PER DETAILS
FOR FUTURE GRAB BARS.
LIGHT SWITCHES, ELECTRICAL OUTLETS,
THERMOSTATS AND OTHER ENVIRONMENTAL
CONTROLS TO BE IN ACCESSIBLE LOCATIONS
AND MEET HEIGHT GUIDELINES.
ENTRY
BEDROOM #3A
9'4" CLG.
10'8 CLG.
30" x 48" CLEAR
FLOOR SPACE
AT LAVATORIES
(TYPICAL)
W2
A/C #2
DRAIN
MIR
W2
9'4" CLG.
SLOPE FLOOR DOWN 2"
SMOKE
BARRIER
TO CEILING
SHOWER
UNIT
9'4" CLG.
SMOKE
BARRIER
TO CEILING
W3
12'0 CLG.
1'-4"
LAV
ROD & SHELF
BATH
2"B"
A/C PAD TO BE
ABOVE BASE
FLOOD ELEVATION
SHOWER
HEAD W/
CONTROLS
2 CAR GARAGE
W3
MIR
W2
SHOWER
HEAD W/
CONTROLS
A/C #3
9'4" CLG.
DRAIN
W2
BATH
1"B"
10'8 CLG.
9'4" CLG.
9'4" CLG.
9'4" CLG.
MIR
SHOWER
UNIT
LINEN
CAB.
BATH 3"B"
SHOWER
HEAD W/
CONTROLS
ROD & SHELF
9'4" CLG.
FOYER
BATH
3"A"
9'4" CLG.
COLUMN IN WALL
SEE STRUCTURAL
PLANS
LAUNDRY
LAV
R-11 INSULATION
9'4" CLG.
9'4" CLG.
W.H.
MIR
W3
RAMP DN. 4"
SMOKE
BARRIER
TO CEILING
W5
W.C.
COLUMN IN WALL
SEE STRUCTURAL
PLANS
BATH
2"A"
SPRINKLER
RISER
LOCATION
HANDICAP
SHOWER
UNIT
GRAB BARS
103
BEDROOM #1B
W2
W4
1'-4" 8"
LAV
ROD & SHELF
S.H. W/
CONT.
W.C.
W2
W.C.
5461 BRIARCLIFF ROAD
FORT MYERS, FLORIDA 33912
9'4" CLG.
MIR
PROTECTED HARBOR
COLUMN IN WALL
SEE STRUCTURAL
PLANS
LAV
LAV
SHELVES
HANDICAPPED
BATH
"
Ø5'-0
5'-10"
W.C.
SHOWER
HEAD W/
CONTROLS
W5
9'4" CLG.
121
SHOWER
UNIT
BLOCKING FOR FUTURE
24" LONG H.C. GRAB BAR
OVER ALL TOILETS CENTERLINE
AND 37" A.F.F.
A/H
OFFICE
DRAIN
MIR
ELECTRIC
PANEL
3670 ARCH
OPENING
9'4" CLG.
NOTE: DOOR 127
SHALL BE WEATHER STRIPPED
AND HAVE A BOTTOM SWEEP
FOR SOUND CONTROL
34" MAX.
W.C.
GAME RM.
ATTIC
ACCESS
SHOWER
UNIT
SHOWER
UNIT
DRAIN
9'4" CLG.
TOP @ 36" A.F.F. (NO
CABINETS BELOW)
22'-0"
MIR
9'4" CLG.
SHOWER
HEAD W/
CONTROLS
A/C #1
ROD & SHELF
W.C.
BATH
1"A"
LAV
A/C PAD TO BE
ABOVE BASE
FLOOD ELEVATION
9'4" CLG.
DRAIN
W1
LOCKABLE
UPPER CABINETS
W4
9'4" CLG.
ROD & SHELF
O.H. CAB
SMOKE BARRIER
TO CEILING
U.C. REF
W/ ICE
COLUMN IN WALL
SEE STRUCTURAL
PLANS
W.I.C.
W.C.
122
REF.
GUARD. "B"
BATH
W.C.
9'4" CLG.
9'4" CLG.
LAV
W2
SHOWER
HEAD W/
CONTROLS
O.H. CAB
9'4" CLG.
9'4" CLG.
KITCHEN
ROD & SHELF
BEDROOM #1A
DBL SINK
DRYER
SMOKE
BARRIER
TO CEILING
MITERED GLASS.
BOT. @ 3'0" A.F.F.
TOP @ 7'0" A.F.F.
GUARDIAN "B"
DW
O.H. CAB
SINK
9'4" CLG.
W4
KNEE WALL
FINISH AT 35" HIGH
W1
SINK
W1
3070 ARCH
OPENING
SHELVES
O.H. CAB
TUB
EGRESS
116
MIR
W.C. TO BE
LOCATED AS
SHOWN (TYP.)
1'-8"
W1
ROD & SHELF
PANTRY
3070 ARCH
OPENING
LAV
VAULTED
REF.
A/H
VAULTED
9'4" CLG.
9'4" CLG.
VAULTED
DRAIN
MAX VAULTED CLG.
VAULTED
W.I.C.
9'4" CLG.
VAULTED CLG.
3070 ARCH
OPENING
GUARD. "A"
BATH
ROD & SHELF
KITCHEN
REF.
LIVING ROOM
VAULTED
DBL SINK
KITCHEN
SHELVES
22'-0"
DW
O.H. CAB
NOTE: DOOR 119
SHALL BE WEATHER STRIPPED
AND HAVE A BOTTOM SWEEP
FOR SOUND CONTROL
SHOWER
HEAD W/
CONTROLS
W.C.
ISLAND
HAND
SINK
9'4" CLG.
HATCHING INDICATES
9'4" CLG.
SOUND INSULATED WALLS
5/8" DRYWALL OUTSIDE SURFACE
OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING BOARD
ON 2X4 WOOD STUDS SPACED 16" O.C.
WITH R-11 FIBERGLASS SOUND INSULATION AND
5/8" DRYWALL INSIDE THE SUITE
SMOKE BARRIER PARTITION W/ SOUND CONTROL
(TYPICAL FOR 2 GUARDIAN SUITES)
ROD & SHELF
VAULTED CLG
GUARDIAN "A"
SHOWER
UNIT
O.H. CAB
DINING
LIVING/DINING
W6
WASHER
W1
9990 coconut road
suite 345
bonita springs, fl 34135
voice 239.777.0616
fax 239.390.1140
license No. AA - 26003057
104
EGRESS
DRYER
9'4" CLG.
105
FIRE
EXTINGUISHER
WASHER
LIVING/DINING
DBL SINK
RANGE W/ HOOD
HATCHING INDICATES
SOUND INSULATED WALLS
5/8" DRYWALL OUTSIDE SURFACE
OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING BOARD
ON 2X4 WOOD STUDS SPACED 16" O.C.
WITH R-11 FIBERGLASS SOUND INSULATION AND
5/8" DRYWALL INSIDE THE SUITE
SMOKE BARRIER PARTITION W/ SOUND CONTROL
(TYPICAL FOR 2 GUARDIAN BEDROOMS)
W4
D.W.
SINK
W/G.D.
FIRE
EXTINGUISHER
4" RISER 106
O.H. CAB
O.H. CAB
FIRE
EXTINGUISHER
103
107
SHELVES
EGRESS
108
August-24-2016
109
RANGE
W/ HOOD
4" RISER
O.H. CAB
104
110
111
O.H. CAB
4" RISER 112
O.H. CAB
105
113
114
3'x4'x4" THICK
CONCRETE SLAB
REF.
115
3'x8'x4" THICK
CONCRETE SLAB
O.H. CAB
3'x4'x4" THICK
CONCRETE SLAB
NOTES:
LAVATORIES SHALL BE MOUNTED
WITH THE RIM OR COUNTER
SURFACE NO HIGHER THAN 34"
ABOVE THE FINISH FLOOR. PROVIDE
A CLEARENCE OF AT LEAST 29"
ABOVE THE FINISH FLOOR TO THE
BOTTOM OF THE APRON.
PIPES UNDER LAVATORIES SHALL
BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT
AGAINST CONTACT. THERE SHALL
BE NO SHARP OR ABRASIVE
SURFACES UNDER LAVATORIES.
W1.- SOUND INSULATED WALLS
5/8" DRYWALL OUTSIDE SURFACE
OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING
BOARD ON 2X4 WOOD STUDS SPACED 16" O.C.
WITH R-11 FIBERGLASS SOUND INSULATION AND
5/8" DRYWALL INSIDE THE SUITE
SMOKE BARRIER PARTITION W/ SOUND CONTROL
W2.- SMOKE BARRIER WALLS
5/8" DRYWALL BOTH SIDES ON
2X4 WOOD STUDS SPACED 16" O.C. WITH
R-11 FIBERGLASS SOUND INSULATION
W3.- 5/8" DRYWALL BOTH SIDES ON
2X4 WOOD STUDS SPACED 16" O.C. WITH
R-11 FIBERGLAS BATT INSULATION
Revisions
Date
1
2
3
4
Drawn By: J.S.
Job No: A02016
Date: 8-24-2016
CONFIDENTIAL COPYRIGHT South Florida Architecture, INC.
W4.- 5/8" DRYWALL BOTH SIDES ON
2X4 WOOD STUDS SPACED 16" O.C.
PURSUANT TO SECTION 102 OF THE COPYRIGHT ACT, 17 U.S.C., ALL CONCEPTS, IDEAS, DESIGNS,
ARRANGEMENTS, DRAWINGS, AND PLANS INDICATED OR REPRESENTED BY THIS DOCUMENT ARE
COPYRIGHTED BY South Florida Architecture, INC. AS SUCH ALL CONCEPTS, IDEAS, DESIGNS,
ARRANGEMENTS, DRAWINGS, AND PLANS INDICATED OR REPRESENTED BY THIS DOCUMENT ARE
OWNED BY AND THE PROPERTY OF South Florida Architecture, INC AND WERE CREATED, EVOLVED
AND DEVELOPED FOR IT'S OWN USE. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS, OR PLANS
SHALL BE USED BY OR DISCLOSED TO ANY PERSON, ARCHITECTURAL OR ENGINEERING FIRM,
CONSTRUCTION FIRM, SUBCONTRACTING FIRM, SUPPLIER, OR CORPORATION FOR ANY PURPOSE
WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF South Florida Architecture, INC.
W5.- 5/8" DRYWALL BOTH SIDES ON
2X6 WOOD STUDS SPACED 16" O.C.
PURSUANT TO SECTION 102 OF THE COPYRIGHT ACT, 17 U.S.C., PROTECTION FOR AN
ARCHITECTURAL WORK CREATED AS A WORK MADE FOR HIRE ON OR AFTER DECEMBER 1, 1990,
LASTS FOR 95 YEARS FROM THE DATE OF PUBLICATION OF THE WORK OR FOR 120 YEARS FROM
THE DATE OF CREATION OF THE UNPUBLISHED PLANS, WHICHEVER TERM IS LESS.
W6.- SOUND INSULATED WALLS
5/8" DRYWALL OUTSIDE SURFACE
OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING
BOARD ON 2X6 WOOD STUDS SPACED 16" O.C.
WITH R-11 FIBERGLASS SOUND INSULATION AND
5/8" DRYWALL INSIDE THE SUITE
SMOKE BARRIER PARTITION W/ SOUND CONTROL
WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER SECTION 102 OF THE
COPYRIGHT ACT, 17 U.S.C.; 18 U.S.C. SEC. 506. UNAUTHORIZED DISCLOSURE MAY CONSTITUTE
TRADE SECRET MISAPPROPRIATION IN VIOLATION OF I.C.24-2-31-1 ET. SEQ. AND OTHER LAWS.
THE CONCEPTS, IDEAS, DESIGNS, ARRANGEMENTS, DRAWINGS, AND PLANS DISCLOSED ARE
COPYRIGHTED AND HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT
APPLICATION. ANYONE VIOLATING THE INTENT OF THIS COPYRIGHT PROTECTION WILL BE
PROSECUTED TO THE FULL EXTENT OF THE FEDERAL STATE AND LOCAL LAWS.
WRITTEN DIMENSIONS ON THESE DOCUMENTS SHALL HAVE PRECEDENCE OVER SCALE
DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND
CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE
DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DRAWINGS AND OR DETAILS
MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING WITH FABRICATION.
LEG CLEARANCE
LAVATORY ELEVATION
SHEET
HANDICAP ACCESSIBLE
GRAB BAR DETAILS
NOTES PLAN
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
NORTH
A-2
PERMIT SET
Download