FIRE EXTINGUISHER 106 120 FLUSH LANDING LAV PULL DOWN LADDER ATTIC ACCESS SHOWER HEAD W/ CONTROLS 9'4" CLG. ELECTRIC PANELS EQUIP. TUB W.H. BEDROOM #2A 9'4" CLG. ATTIC ACCESS 9'4" CLG. A/H 1'-4" EGRESS 108 117 1'-4" 8'-2" R-11 INSULATION CLOSET EGRESS ROD & SHELF 143 R-11 INSULATION BEDROOM #3B BEDROOM #2B W4 9'4" CLG. CLOSET 9'4" CLG. 9'4" CLG. EGRESS 1'RISER EGRESS 102 101 15' CLG. No. ELECTRIC METER 9'4" CLG. 102 RAMP UP 6" INTERIOR WALL TYPES PROVIDE BLOCKING AS REQUIRED TO ACCOMMODATE FUTURE GRAB BAR INSTALLATION W4 54" MIN. 1'-0" 36" MIN. 24" MIN. 12" MIN. 42" MIN. 6" MAX 119 CONCRETE BLOCK COLUMN. SEE STRUCTURAL DRAWINGS CONCRETE BEAM FURRED OUT TO MATCH COLUMN WIDTH. SEE STRUCTURAL DRAWINGS CONCRETE SIDEWALK CONCRETE BLOCK COLUMN. SEE STRUCTURAL DRAWINGS (a) (b) SIDE WALL BACK WALL HANDICAP ACCESSIBLE GRAB BAR DETAILS SCALE: 1/4" = 1'-0" AREA SUMMARY DOOR 106 BETWEEN GARAGE AND LIVING SPACE TO BE 20 MINUTE RATED OR 1 3/8" THICK SOLID WOOD OR 1 3/8" THICK METAL DOOR. MAIN LIVING A/C GARAGE ENTRY 5,278 S.F. 568 S.F. 143 S.F. GRAND TOTAL 5,989 S.F. 11" MIN. 17" MIN. 29" MIN. TOE CLEARANCE 27" MIN. 8" MIN. 9" MIN. ALL UNPROTECTED DRS. & WINDOWS TO BE RATED & LABELED FOR MAX. REQUIRED WINDLOADS. COORDINATION OF CONSTRUCTION, INCLUDING VERIFICATION OF DIMENSIONS & FIELD CONDITIONS, IS THE RESPONSIBILITY OF THE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN FIRM PRIOR TO CONSTRUCTION. TRAP WRAP FIRST FLOOR 38" MAX. NOTE: ALL WINDOWS AND DOORS TO BE PGT (SEE BUILDER FOR DETAILS) 33" - 36" 18" 1 A-7 19" min 17" - 19" CONCRETE BEAM FURRED OUT TO MATCH COLUMN WIDTH. SEE STRUCTURAL DRAWINGS EGRESS 33" - 36" 1'-3" 118 ACCESSIBILITY GUIDELINES PER FLORIDA BUILDING CODE AND FAIR HOUSING ACT ARE REQUIRED IN THIS FACILITY AND ARE MET BY THESE PLANS. REQUIRED CLEARANCES IN KITCHENS, ALL BATHROOMS AND LAUNDRY ROOM SHALL MEET MINIMUMS AS PER THE ATTACHED SHEET A8. USABLE DOORS AND AN ACCESSIBLE ROUTE INTO AND THROUGH THE BUILDING HAVE BEEN PROVIDED. BLOCKING IN BATH WALLS SHALL BE INSTALLED PER DETAILS FOR FUTURE GRAB BARS. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS TO BE IN ACCESSIBLE LOCATIONS AND MEET HEIGHT GUIDELINES. ENTRY BEDROOM #3A 9'4" CLG. 10'8 CLG. 30" x 48" CLEAR FLOOR SPACE AT LAVATORIES (TYPICAL) W2 A/C #2 DRAIN MIR W2 9'4" CLG. SLOPE FLOOR DOWN 2" SMOKE BARRIER TO CEILING SHOWER UNIT 9'4" CLG. SMOKE BARRIER TO CEILING W3 12'0 CLG. 1'-4" LAV ROD & SHELF BATH 2"B" A/C PAD TO BE ABOVE BASE FLOOD ELEVATION SHOWER HEAD W/ CONTROLS 2 CAR GARAGE W3 MIR W2 SHOWER HEAD W/ CONTROLS A/C #3 9'4" CLG. DRAIN W2 BATH 1"B" 10'8 CLG. 9'4" CLG. 9'4" CLG. 9'4" CLG. MIR SHOWER UNIT LINEN CAB. BATH 3"B" SHOWER HEAD W/ CONTROLS ROD & SHELF 9'4" CLG. FOYER BATH 3"A" 9'4" CLG. COLUMN IN WALL SEE STRUCTURAL PLANS LAUNDRY LAV R-11 INSULATION 9'4" CLG. 9'4" CLG. W.H. MIR W3 RAMP DN. 4" SMOKE BARRIER TO CEILING W5 W.C. COLUMN IN WALL SEE STRUCTURAL PLANS BATH 2"A" SPRINKLER RISER LOCATION HANDICAP SHOWER UNIT GRAB BARS 103 BEDROOM #1B W2 W4 1'-4" 8" LAV ROD & SHELF S.H. W/ CONT. W.C. W2 W.C. 5461 BRIARCLIFF ROAD FORT MYERS, FLORIDA 33912 9'4" CLG. MIR PROTECTED HARBOR COLUMN IN WALL SEE STRUCTURAL PLANS LAV LAV SHELVES HANDICAPPED BATH " Ø5'-0 5'-10" W.C. SHOWER HEAD W/ CONTROLS W5 9'4" CLG. 121 SHOWER UNIT BLOCKING FOR FUTURE 24" LONG H.C. GRAB BAR OVER ALL TOILETS CENTERLINE AND 37" A.F.F. A/H OFFICE DRAIN MIR ELECTRIC PANEL 3670 ARCH OPENING 9'4" CLG. NOTE: DOOR 127 SHALL BE WEATHER STRIPPED AND HAVE A BOTTOM SWEEP FOR SOUND CONTROL 34" MAX. W.C. GAME RM. ATTIC ACCESS SHOWER UNIT SHOWER UNIT DRAIN 9'4" CLG. TOP @ 36" A.F.F. (NO CABINETS BELOW) 22'-0" MIR 9'4" CLG. SHOWER HEAD W/ CONTROLS A/C #1 ROD & SHELF W.C. BATH 1"A" LAV A/C PAD TO BE ABOVE BASE FLOOD ELEVATION 9'4" CLG. DRAIN W1 LOCKABLE UPPER CABINETS W4 9'4" CLG. ROD & SHELF O.H. CAB SMOKE BARRIER TO CEILING U.C. REF W/ ICE COLUMN IN WALL SEE STRUCTURAL PLANS W.I.C. W.C. 122 REF. GUARD. "B" BATH W.C. 9'4" CLG. 9'4" CLG. LAV W2 SHOWER HEAD W/ CONTROLS O.H. CAB 9'4" CLG. 9'4" CLG. KITCHEN ROD & SHELF BEDROOM #1A DBL SINK DRYER SMOKE BARRIER TO CEILING MITERED GLASS. BOT. @ 3'0" A.F.F. TOP @ 7'0" A.F.F. GUARDIAN "B" DW O.H. CAB SINK 9'4" CLG. W4 KNEE WALL FINISH AT 35" HIGH W1 SINK W1 3070 ARCH OPENING SHELVES O.H. CAB TUB EGRESS 116 MIR W.C. TO BE LOCATED AS SHOWN (TYP.) 1'-8" W1 ROD & SHELF PANTRY 3070 ARCH OPENING LAV VAULTED REF. A/H VAULTED 9'4" CLG. 9'4" CLG. VAULTED DRAIN MAX VAULTED CLG. VAULTED W.I.C. 9'4" CLG. VAULTED CLG. 3070 ARCH OPENING GUARD. "A" BATH ROD & SHELF KITCHEN REF. LIVING ROOM VAULTED DBL SINK KITCHEN SHELVES 22'-0" DW O.H. CAB NOTE: DOOR 119 SHALL BE WEATHER STRIPPED AND HAVE A BOTTOM SWEEP FOR SOUND CONTROL SHOWER HEAD W/ CONTROLS W.C. ISLAND HAND SINK 9'4" CLG. HATCHING INDICATES 9'4" CLG. SOUND INSULATED WALLS 5/8" DRYWALL OUTSIDE SURFACE OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING BOARD ON 2X4 WOOD STUDS SPACED 16" O.C. WITH R-11 FIBERGLASS SOUND INSULATION AND 5/8" DRYWALL INSIDE THE SUITE SMOKE BARRIER PARTITION W/ SOUND CONTROL (TYPICAL FOR 2 GUARDIAN SUITES) ROD & SHELF VAULTED CLG GUARDIAN "A" SHOWER UNIT O.H. CAB DINING LIVING/DINING W6 WASHER W1 9990 coconut road suite 345 bonita springs, fl 34135 voice 239.777.0616 fax 239.390.1140 license No. AA - 26003057 104 EGRESS DRYER 9'4" CLG. 105 FIRE EXTINGUISHER WASHER LIVING/DINING DBL SINK RANGE W/ HOOD HATCHING INDICATES SOUND INSULATED WALLS 5/8" DRYWALL OUTSIDE SURFACE OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING BOARD ON 2X4 WOOD STUDS SPACED 16" O.C. WITH R-11 FIBERGLASS SOUND INSULATION AND 5/8" DRYWALL INSIDE THE SUITE SMOKE BARRIER PARTITION W/ SOUND CONTROL (TYPICAL FOR 2 GUARDIAN BEDROOMS) W4 D.W. SINK W/G.D. FIRE EXTINGUISHER 4" RISER 106 O.H. CAB O.H. CAB FIRE EXTINGUISHER 103 107 SHELVES EGRESS 108 August-24-2016 109 RANGE W/ HOOD 4" RISER O.H. CAB 104 110 111 O.H. CAB 4" RISER 112 O.H. CAB 105 113 114 3'x4'x4" THICK CONCRETE SLAB REF. 115 3'x8'x4" THICK CONCRETE SLAB O.H. CAB 3'x4'x4" THICK CONCRETE SLAB NOTES: LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. PROVIDE A CLEARENCE OF AT LEAST 29" ABOVE THE FINISH FLOOR TO THE BOTTOM OF THE APRON. PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. W1.- SOUND INSULATED WALLS 5/8" DRYWALL OUTSIDE SURFACE OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING BOARD ON 2X4 WOOD STUDS SPACED 16" O.C. WITH R-11 FIBERGLASS SOUND INSULATION AND 5/8" DRYWALL INSIDE THE SUITE SMOKE BARRIER PARTITION W/ SOUND CONTROL W2.- SMOKE BARRIER WALLS 5/8" DRYWALL BOTH SIDES ON 2X4 WOOD STUDS SPACED 16" O.C. WITH R-11 FIBERGLASS SOUND INSULATION W3.- 5/8" DRYWALL BOTH SIDES ON 2X4 WOOD STUDS SPACED 16" O.C. WITH R-11 FIBERGLAS BATT INSULATION Revisions Date 1 2 3 4 Drawn By: J.S. Job No: A02016 Date: 8-24-2016 CONFIDENTIAL COPYRIGHT South Florida Architecture, INC. W4.- 5/8" DRYWALL BOTH SIDES ON 2X4 WOOD STUDS SPACED 16" O.C. PURSUANT TO SECTION 102 OF THE COPYRIGHT ACT, 17 U.S.C., ALL CONCEPTS, IDEAS, DESIGNS, ARRANGEMENTS, DRAWINGS, AND PLANS INDICATED OR REPRESENTED BY THIS DOCUMENT ARE COPYRIGHTED BY South Florida Architecture, INC. AS SUCH ALL CONCEPTS, IDEAS, DESIGNS, ARRANGEMENTS, DRAWINGS, AND PLANS INDICATED OR REPRESENTED BY THIS DOCUMENT ARE OWNED BY AND THE PROPERTY OF South Florida Architecture, INC AND WERE CREATED, EVOLVED AND DEVELOPED FOR IT'S OWN USE. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS, OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, ARCHITECTURAL OR ENGINEERING FIRM, CONSTRUCTION FIRM, SUBCONTRACTING FIRM, SUPPLIER, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF South Florida Architecture, INC. W5.- 5/8" DRYWALL BOTH SIDES ON 2X6 WOOD STUDS SPACED 16" O.C. PURSUANT TO SECTION 102 OF THE COPYRIGHT ACT, 17 U.S.C., PROTECTION FOR AN ARCHITECTURAL WORK CREATED AS A WORK MADE FOR HIRE ON OR AFTER DECEMBER 1, 1990, LASTS FOR 95 YEARS FROM THE DATE OF PUBLICATION OF THE WORK OR FOR 120 YEARS FROM THE DATE OF CREATION OF THE UNPUBLISHED PLANS, WHICHEVER TERM IS LESS. W6.- SOUND INSULATED WALLS 5/8" DRYWALL OUTSIDE SURFACE OVER SOUND CHOICE 1/2"- 4' x 8' SHEATHING BOARD ON 2X6 WOOD STUDS SPACED 16" O.C. WITH R-11 FIBERGLASS SOUND INSULATION AND 5/8" DRYWALL INSIDE THE SUITE SMOKE BARRIER PARTITION W/ SOUND CONTROL WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER SECTION 102 OF THE COPYRIGHT ACT, 17 U.S.C.; 18 U.S.C. SEC. 506. UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF I.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE CONCEPTS, IDEAS, DESIGNS, ARRANGEMENTS, DRAWINGS, AND PLANS DISCLOSED ARE COPYRIGHTED AND HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION. ANYONE VIOLATING THE INTENT OF THIS COPYRIGHT PROTECTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE FEDERAL STATE AND LOCAL LAWS. WRITTEN DIMENSIONS ON THESE DOCUMENTS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DRAWINGS AND OR DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING WITH FABRICATION. LEG CLEARANCE LAVATORY ELEVATION SHEET HANDICAP ACCESSIBLE GRAB BAR DETAILS NOTES PLAN SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" NORTH A-2 PERMIT SET