CAT : No.725-07E-C Check Valves VUCL SERIES ADZS A.Z ABF (I) AE-ZD ADZS A.Z ABF (I) AE-ZB Features Dimensions Fixed Cracking Pressures Dimensions, shown with Lok tube fitting nuts finger-tight, are for reference only and are subject to change. From 1/3 to 25 psi (0.03 to 1.8 bar) (Standard: 1 psig) A B (flat) Technical Data Check valves are designed for directional flow control only. Check valves should never be used as code safety relief devices. Temperature and Pressure Rating End Connections: 7000 Lok, Rc1/4 100 ゜ F (37 ℃), 6000 psig (413 bar) 6000 Pressure (psig) 5000 4000 Pressure (psig) 250 ゜ F (121 ℃), 4910 psig (338 bar) 200 ゜ F (93 ℃),5160 psig (355 bar) 3000 300 ゜ F (148 ℃), 4660 psig (321 bar) 2000 400 ゜ F (204 ℃), 4280 psig (294bar) 1000 0 -50 -10 0 50 100 150 200 250 300 350 400 450 6000 5500 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 End Connections: Rc1/2 100 ゜ F (37 ℃), 5100 psig (351 bar) 200 ゜ F (93 ℃), 4411 psig (299 bar) End Connections 300 ゜ F (148 ℃), 3978 psig (271 bar) 400 ゜ F (204 ℃), 3646 psig (251 bar) -50 -10 0 50 Temperature (゜ F) 150 250 350 450 Temperature (゜ F) Cracking and Reseal Pressures at 70 ° F (20 ° C) Nominal Cracking Pressure psig (bar) Cracking Pressure Range psig(bar) 1/3 (0.03) 1 (0.07) 5 (0.35) 10 (0.69) 25 (1.8) Up to 3 (0.21) Up to 4 (0.28) 3 to 9 (0.21 to 0.63) 7 to 15 (0.49 to 1.1) 20 to 30 (1.4 to 2.1) ※1 Reseal Pressure psig(bar) ※2 6 (0.42) or more back pressure 5 (0.35) or more back pressure 2 (0.14) or more back pressure 3 (0.21) or less upstream pressure 17 (1.2) or less upstream pressure ※1: Upstream pressure at the start of first flow The start of first flow means, by pressurizing from the upstream after putting the outlet pipe into water, the continuous air bubble coming through the outlet. ※1: Cracking Pressure: The inlet pressure at which the first indication of flow occurs(steady stream of bubbles) . ※2: The pressure when the flow is not confirmed any more 【Nominal Cracking Pressure:0.003 to 0.035MPa】 Each reverse pressure according to the cracking pressure is necessary for sealing at a valve seat. The reverse pressure is the pressure of deducting the upstream pressure from the outlet pressure. ※2: Reseal Pressure : The pressure at which there is no indication of flow. 【Nominal Cracking Pressure:0.069 to 0.18MPa】 When the upstream pressure is below the value shown on the table, a valve seat is resealed. Applicable fluid Rc ① Valve Series Materials of Construction ② Body Material Stainless Steel 1 3 4 7 5 6 2 8 9 10 No. Description 1 2 3 4 5 6 7 8 9 10 BODY1 BODY2 POPPET POPPET STOP O-RING BACKUP RING SPRING FRONT RING BACK RING NUT ※:Wetted parts Materials ※ ※ ※ ※ ※ ※ ※ ※ ASTM A479 316 ASTM A479 316 SUS 316L + FKM ASTM A276 316 FKM PTFE SUS316 ASTM A276 316 ASTM A276 316 ASTM A276 316 Dimensions in. (mm) B 1/4 in. (6.35) 2.43 (61.7) 11/16 (17.5) 3/8 in. (9.52) 2.75 (69.9) 1/2 in. (12.7) 2.96 (75.2) 6 mm 6000 (413) 2.43 (61.7) Cracking Pressure psig (bar) VUCL-941-6.35-0.07 VUCL-941-9.52-0.07 1 (25.4) 11/16 (17.5) 2.7 (68.6) 1 (25.4) Ordering Numbers VUCL-941-12.7-0.07 1 (0.07) VUCL-941-6-0.07 VUCL-941-8-0.07 10 mm 2.8 (71.1) 12 mm 2.96 (75.2) 1/4 in. 2.28 (57.9) 11/16 (17.5) VUCL-141B-0.07 3.29 (83.6) 1-1/16 (27) VUCL-141D-0.07 1/2 in. 5100 (351) VUCL-941-10-0.07 VUCL-941-12-0.07 Ordering Information Attention and asking in selection 1. The pressure more than the reseal pressure is necessary for sealing of seat. 2. For valves not actuated for a period of time, initial cracking pressure may be higher than the set cracking pressure. 3. In general Check Valves are used for only direction control of flow. Please don't use check valves for ON - OFF values. Working Pressure psig (bar) A 8 mm ①② ③ Air, Nitrogen gas, Inert gas like Helium, and non - corrosive gas and liquid. 1 Lok Nominal Sizes ③ Valve Type Check Valves ④⑤ ⑥ ⑦ ⑥ Connection Sizes 6.35: Lok 6.35 9.52: Lok 9.52 12.7: Lok 12.7 ⑤ Working Pressure 6: Lok 6 6000 psig (413 bar) 8: Lok 8 10: Lok 10 12: Lok 12 B: Rc1/4 D: Rc1/2 ④ End Connections 1: Screwed Type 9: Lok Type ⑦ Cracking Pressures 0.07: 1 psig (0.07 bar) 0.03: 1/3 psig (0.0 3bar) 0.35: 5 psig (0.35 bar) 0.69: 10 psig (0.69 bar) 1.8: 25 psig (1.8 bar) 2 Features Dimensions Fixed Cracking Pressures Dimensions, shown with Lok tube fitting nuts finger-tight, are for reference only and are subject to change. From 1/3 to 25 psi (0.03 to 1.8 bar) (Standard: 1 psig) A B (flat) Technical Data Check valves are designed for directional flow control only. Check valves should never be used as code safety relief devices. Temperature and Pressure Rating End Connections: 7000 Lok, Rc1/4 100 ゜ F (37 ℃), 6000 psig (413 bar) 6000 Pressure (psig) 5000 4000 Pressure (psig) 250 ゜ F (121 ℃), 4910 psig (338 bar) 200 ゜ F (93 ℃),5160 psig (355 bar) 3000 300 ゜ F (148 ℃), 4660 psig (321 bar) 2000 400 ゜ F (204 ℃), 4280 psig (294bar) 1000 0 -50 -10 0 50 100 150 200 250 300 350 400 450 6000 5500 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 End Connections: Rc1/2 100 ゜ F (37 ℃), 5100 psig (351 bar) 200 ゜ F (93 ℃), 4411 psig (299 bar) End Connections 300 ゜ F (148 ℃), 3978 psig (271 bar) 400 ゜ F (204 ℃), 3646 psig (251 bar) -50 -10 0 50 Temperature (゜ F) 150 250 350 450 Temperature (゜ F) Cracking and Reseal Pressures at 70 ° F (20 ° C) Nominal Cracking Pressure psig (bar) Cracking Pressure Range psig(bar) 1/3 (0.03) 1 (0.07) 5 (0.35) 10 (0.69) 25 (1.8) Up to 3 (0.21) Up to 4 (0.28) 3 to 9 (0.21 to 0.63) 7 to 15 (0.49 to 1.1) 20 to 30 (1.4 to 2.1) ※1 Reseal Pressure psig(bar) ※2 6 (0.42) or more back pressure 5 (0.35) or more back pressure 2 (0.14) or more back pressure 3 (0.21) or less upstream pressure 17 (1.2) or less upstream pressure ※1: Upstream pressure at the start of first flow The start of first flow means, by pressurizing from the upstream after putting the outlet pipe into water, the continuous air bubble coming through the outlet. ※1: Cracking Pressure: The inlet pressure at which the first indication of flow occurs(steady stream of bubbles) . ※2: The pressure when the flow is not confirmed any more 【Nominal Cracking Pressure:0.003 to 0.035MPa】 Each reverse pressure according to the cracking pressure is necessary for sealing at a valve seat. The reverse pressure is the pressure of deducting the upstream pressure from the outlet pressure. ※2: Reseal Pressure : The pressure at which there is no indication of flow. 【Nominal Cracking Pressure:0.069 to 0.18MPa】 When the upstream pressure is below the value shown on the table, a valve seat is resealed. Applicable fluid Rc ① Valve Series Materials of Construction ② Body Material Stainless Steel 1 3 4 7 5 6 2 8 9 10 No. Description 1 2 3 4 5 6 7 8 9 10 BODY1 BODY2 POPPET POPPET STOP O-RING BACKUP RING SPRING FRONT RING BACK RING NUT ※:Wetted parts Materials ※ ※ ※ ※ ※ ※ ※ ※ ASTM A479 316 ASTM A479 316 SUS 316L + FKM ASTM A276 316 FKM PTFE SUS316 ASTM A276 316 ASTM A276 316 ASTM A276 316 Dimensions in. (mm) B 1/4 in. (6.35) 2.43 (61.7) 11/16 (17.5) 3/8 in. (9.52) 2.75 (69.9) 1/2 in. (12.7) 2.96 (75.2) 6 mm 6000 (413) 2.43 (61.7) Cracking Pressure psig (bar) VUCL-941-6.35-0.07 VUCL-941-9.52-0.07 1 (25.4) 11/16 (17.5) 2.7 (68.6) 1 (25.4) Ordering Numbers VUCL-941-12.7-0.07 1 (0.07) VUCL-941-6-0.07 VUCL-941-8-0.07 10 mm 2.8 (71.1) 12 mm 2.96 (75.2) 1/4 in. 2.28 (57.9) 11/16 (17.5) VUCL-141B-0.07 3.29 (83.6) 1-1/16 (27) VUCL-141D-0.07 1/2 in. 5100 (351) VUCL-941-10-0.07 VUCL-941-12-0.07 Ordering Information Attention and asking in selection 1. The pressure more than the reseal pressure is necessary for sealing of seat. 2. For valves not actuated for a period of time, initial cracking pressure may be higher than the set cracking pressure. 3. In general Check Valves are used for only direction control of flow. Please don't use check valves for ON - OFF values. Working Pressure psig (bar) A 8 mm ①② ③ Air, Nitrogen gas, Inert gas like Helium, and non - corrosive gas and liquid. 1 Lok Nominal Sizes ③ Valve Type Check Valves ④⑤ ⑥ ⑦ ⑥ Connection Sizes 6.35: Lok 6.35 9.52: Lok 9.52 12.7: Lok 12.7 ⑤ Working Pressure 6: Lok 6 6000 psig (413 bar) 8: Lok 8 10: Lok 10 12: Lok 12 B: Rc1/4 D: Rc1/2 ④ End Connections 1: Screwed Type 9: Lok Type ⑦ Cracking Pressures 0.07: 1 psig (0.07 bar) 0.03: 1/3 psig (0.0 3bar) 0.35: 5 psig (0.35 bar) 0.69: 10 psig (0.69 bar) 1.8: 25 psig (1.8 bar) 2